Loading...
Report (5) Oregon Residential Specialty Code R408.1 MOISTURE BARRIER ACKNOWLEDGEMENT FORM I' T4-A 1'' � „ i a ti S am the general contractor or the owner-builder at the following address: Site Address: 1`1ZS5" SL-N tc,Ar A-4. e. City: Permit#: \C1-0(73'„3 Subdivision/Lot#: -t and/or Map and Tax Lot#: To confonrwith the 2014 Oregon Residential Specialty Code(ORSC),Section R408.1 Ventilation.I am notifying the building official that I have installed the Moisture Barrier as per Requirement in ORSC Section 408.1 and have taken the following steps to meet this code requirement: (JThe ground surface of the under-floor space is covered with 6-mil black polyethylene sheeting with Rfoints lapped 12"at seams and }finding up the foundation walls 12". Signature: raaer4'rot urn or Owner- ,shirr Date: t! L a I vkak fyttarooths-Mnurvaf ono doc 09/13/2016 Oregon Residential Specialty Code R318.2 MOISTURE CONTENT ACKNOWLEDGEMENT FORM am the general contractor or the owner-builder at the following address: Site Address tvIZYS' SW tCar1�' A.. )t City. —77 Permit#: Subdivision/Lot#: 4, and/or Map and'^ax Lot#: To conform with the 2008 Oregon Residential Specialty Code(ORSC),Section R318.2 and OAR 918-480-0140,I am notifying the building official that I am aware of the moisture content Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement [Section R318.2 is provided for reference]. R318.2 Moisture Cement: Prior to the installation of interior finishes,the building official shall be notified in writing by the general contractor that all moisture-sensitive wood framing members used in construction have a moisture content of not more than 19 percent by dry weight of dry framing members. Si HTUte: tl/ crgr or Owocr Builder ----_._- Date: t It ( 1.t&aidmrFofm1aE3-Mo mr$arouraWood dor 09'251t . Oregon Residential Specialty Code N1107.2 HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS Pearut , 14 00 sx-5 Jurisdiction: Site Address.: 11"11 $.-. La clN 404-- SubdivisionfLot#: (s1 and/or Map and Tax Lot#: By my signature below,I certify that a minimum of fifty(50)percent of the permanendy installed lighting fixtures in the above mentioned building have been ineralled with compact or linear fluorescent,or a lighting source that has a minimum efficacy of 40 lumens per input watt. (Oregon Residential Specialty Code NI 1072)) 0/ Signature: Date: II Owns, riabtractorfAuthesiied Agent Print Name: ORSC Samoa N1107..2.High-efficiency interior lighting system A 121113IIIIUM of ftfty(SO)percent o the percowneady misalled lighting future*shall be vostallal with compact or!mar thiorwicent,or a lighting source that has s mamma efficacy of 40 Maims pa input watt Screw-in compact fluoreacts lamps comply with this raimmaem The braiding official dad be notified in wawa at the finial usspecnon that a minimum of fdly percent of the paspormity signalled lighting fixtures are compact or hour fluorescent,or a muumuu efficacy of 40 lumens pa spa VOL illihillieramites-itywiamsoyuormagaux 1t1IO5 , Moffet Energy Modeling CCB#223372 Phone: 916-342-0742 tvler@moffetco.com Blower Door Test Affidavit Permit#: Builder: Taylor Morrison Site Address: Roshak Lot 67: 14255 SW 169th Ave,Tigard, OR 97224 Conditioned Floor Area (sq.ft.): 1649 Source: Calculated from plans Calculated Building Volume (cubic feet): 15750 TEST RESULTS: 1249 CFM @ 50 Pa ACH @ 50 Pa = {(CFM x 60)-Volume}: 4.76 Ring: Open oA B Minneapolis Blower Door and DG 700 Manometer I certify that these building leakage rates are accurate and determined using standard BPI testing protocol. Company Name: Moffet Energy Modeling Technician: Tyler Moffet Technician Signature: 7 1 77�1 Date: 11/10/2020