Report (5) Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I' T4-A 1'' � „ i a ti S am the general contractor or the owner-builder
at the following address:
Site Address:
1`1ZS5" SL-N tc,Ar A-4. e.
City:
Permit#: \C1-0(73'„3
Subdivision/Lot#: -t
and/or
Map and Tax Lot#:
To confonrwith the 2014 Oregon Residential Specialty Code(ORSC),Section R408.1
Ventilation.I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
(JThe ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
Rfoints lapped 12"at seams and
}finding up the foundation walls 12".
Signature:
raaer4'rot urn or Owner- ,shirr Date: t! L a
I vkak fyttarooths-Mnurvaf ono doc 09/13/2016
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
am the general contractor or the owner-builder
at the following address:
Site Address
tvIZYS' SW tCar1�' A.. )t
City. —77
Permit#:
Subdivision/Lot#: 4,
and/or
Map and'^ax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC),Section R318.2 and
OAR 918-480-0140,I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement
[Section R318.2 is provided for reference].
R318.2 Moisture Cement: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Si HTUte: tl/
crgr or Owocr Builder ----_._-
Date: t It (
1.t&aidmrFofm1aE3-Mo mr$arouraWood dor 09'251t
.
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Pearut , 14 00 sx-5 Jurisdiction:
Site Address.: 11"11 $.-. La clN 404--
SubdivisionfLot#: (s1
and/or
Map and Tax Lot#:
By my signature below,I certify that a minimum of fifty(50)percent of the permanendy
installed lighting fixtures in the above mentioned building have been ineralled with compact or
linear fluorescent,or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code NI 1072))
0/
Signature:
Date: II
Owns, riabtractorfAuthesiied Agent
Print Name:
ORSC Samoa N1107..2.High-efficiency interior lighting system A 121113IIIIUM of ftfty(SO)percent o the
percowneady misalled lighting future*shall be vostallal with compact or!mar thiorwicent,or a lighting source that
has s mamma efficacy of 40 Maims pa input watt Screw-in compact fluoreacts lamps comply with this
raimmaem
The braiding official dad be notified in wawa at the finial usspecnon that a minimum of fdly percent of the
paspormity signalled lighting fixtures are compact or hour fluorescent,or a muumuu efficacy of 40 lumens pa
spa VOL
illihillieramites-itywiamsoyuormagaux 1t1IO5
,
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tvler@moffetco.com
Blower Door Test Affidavit
Permit#: Builder: Taylor Morrison
Site Address: Roshak Lot 67: 14255 SW 169th Ave,Tigard, OR 97224
Conditioned Floor Area (sq.ft.): 1649
Source: Calculated from plans Calculated Building Volume (cubic feet): 15750
TEST RESULTS: 1249 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60)-Volume}: 4.76
Ring: Open oA B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician: Tyler Moffet
Technician Signature: 7 1 77�1 Date: 11/10/2020