Report (2) Michael K. Brown, S.E. 5346 E. Branchwood Dr. Boise, ID 83716 208-850-7542 mike.brown@@core-engineering.net May 21, 2021 130to Su. 1-..Cw 81.3k e,# . Andy Thomas Stonebridge Homes 4230 Galewood St., Suite 100 iktsT Zv, 2, °00024 Lake Oswego, OR 97035 Re: Number of King Studs at Openings L. . 12. ."% Dear Andy: I'? . tic Per ORSC table R602.3(5) the maximum spacing of wall studs supporting one floor plus a roof-ceiling assembly is 24" o.c. Therefore, at a 2-story condition, follow the requirements for studs spaced at 24" o.c. at Table R602.7.5. Header Span Number of King Studs < or = 4' 1 8' 2 12' 3 16' 4 Please note that at portal frames, such as garage openings where headers are continuous over opening and extend to end of wall, king studs are not used. The Perpendicular wall where the header ends resists that out of plane load that the king studs would be resisting. If you have any questions, please do not hesitate to contact me. Sincerely, .0 CTUg44' .. PRi7f _4,,',',"4i.,,,.. fit. f 4. 4 . 1 F de, ,,,.. tp,oR ct,,, :,..... via. ,, ,,,ot ,,, ,,,,, Michael K. Brown, S.E. 'EXPIRATION DATE 12-31-2021