Loading...
Specifications (2) ivi , 2o-o03,Z, W,F0 Si../ A 1/4-tJoC4 Structural "Gravity and Lateral" Calculations For New addition above existing garage of single family residence Located At 9680 SW Riverwood Lane, Tigard, OR 97224 Jurisdiction: Tigard 41/40tp PR Fs 11/1/2020 0,Gf Ne it) Revised 12/13/20, 2-4-2021 7 E ir Calculations and Sketches GON 02 by y90`7f't5. " ►+ Mark Ennis, PE rEPHES for Tim Austin !EXPIRES: 12-31- 2021 Page G1 to G4 Gravity Calculations Page Ll to L5 Prescriptive Wall Bracing Codes: 2017 ORSC based on the 2015 IRC, Gravity Load: Floor Live=40psf, Roof(Snow) Load=25psf Lateral Design: Prescriptive Summary These calculations are for a new 2nd floor adddition above an existing 1-story garage. Revisions as follows dated 2-4-2021: 1.The existing garage stud walls were 2x4@16"oc and they are OK to remain. 2.The glulam beam in garage is OK to have a 2"hole and a 2-9/16" hole as shown on drawings. 3.The existing 3-1/2"x13" DF header at garage door is OK to remain with an 1-3/4"x14" LVL attached to inside face with (3) 1/4x SDS screws at 24"oc. Extend 6"past garage door opening at each end. 4.Connect the new addition top plate with the existing using a CS22 x 24"strap. (12"old and 12"new)