Report (4) Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: As-r cog) .56
Jurisdiction: ---
Site Address:
6 st-j) C_z)A .,
Subdivision/Lot#:
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature: Date:
tractor/Authorized Agent
Print Name: n,..).„
ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt
I:\BuildingTonns\RES-HighEfficiencyLighting.doc 07/01/08
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
, am the general contractor or the owner-builder
at the following address:
Site Address:
Z.--$1,7
City:
Permit#:
aDD2r) Ob
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
FR—Ihe ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
EgTO-ints lapped 12"at seams and
fending up the foundation walls 12".
Signatut Date:
or Owner-Builder
LtSuildineForm\RES-MoistureBarrier.doc 09/13/2016
_ .
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
3sSa,k.A.k,S , am the general contractor or the owner-builder
at the following address:
Site Address:
City:
Z. (s
Permit#:
NASTa-C).9-b C)k--,27b
Subdivisiona,ot#: t t,
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
(Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by thy weight of dry framing members.
(
Date:
to or Owner-Builder
IABuildingWorm1RES-MoistureSensitiveWood,doc 0925/08
r
r
I
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
L'''''
tyler@moffetco.com
Blower Door Test Affidavit
Permit#: Builder:
Taylor Morrison
Site Address: Roshak Lot 108: 14256 SW Gold Coast Ter,Tigard, OR 97224
Conditioned Floor Area (sq.ft.): 1168
Source: Calculated from plans Calculated Building Volume (cubic feet): 10950
TEST RESULTS: 702 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60)-Volume): 3.85
Ring: Open A O
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician: Tyler Moffet
Technician Signature: 7
71 1-O Date: 12/16/2020
1
dIiY1/y ii-s- a. 1Ng1.11-A'T10'Nl
Certificate of Compliance
This document certifies that the fiberglass insulation has been installed in conformance
with the manufacturer's recommendations and requirements to provide thermal resistance value(s)of:
R-value Thickness Coverage Area
Ceilings: R-49 X New Construction
Vaults/Slopes:
.
Walls: i Upgrade
Blown in R-23
Rim Joist:
Floors:
Over Garage R-38
Crawl Vapor Barrier installed_Y _N Sprinkler Tenting 4 mil Poly x Y N
Loose-Fill Insulation
R-49 using bags of insulation to cover 576 square feet of area at a thickness of 16.75 inches.
Owens Corning`PROPINK°L77 Loosefill Insulation
Owens Coming will accept no responsibility when the product is not installed in accordance with the product label.Stated R-value is provided by
installing the required number ofbags at a thickness not less than the labeled minimum thickness.Installation of the required number ofbags may yield
more than the specifi ed minimum thickness.Failure by the installer to provide both the required bags and at least the minimum thickness will result
in lower insulation R-value.
R-VALUE BAGS PER MAXIMUM NET MINIMUM WEIGHT MINUMUM
1000 SQ.FT. COVERAGE PER SQ.FT. THICKNESS
To obtain a No.of bags per 1000 sq. Contents of this bag Weight per sq.ft.of Installed insulation
thermal resistance ft.of net area: should not cover installed insul.should should not be less
(R)of: more than:(sq.ft.) not be less than:(lbs.) than:(in.)
60 28.0 35.8 0.895 20.00
49 22.2 45.0 0.711 16.75
11 19.7 50.7 0.631 15.00
38 16.7 59.9 0.534 13.25
30 13.0 77.0 0.416 10.50
26 11.2 89.6 0.357 9.25 1
22 9.4 106.3 0.301 8.00
19 8.0 125.0 0.256 7.00
13 5.4 184.6 0.173 4.75
Property Address: 14256 SW Gold Coast Terrace Lot 108, Tigard, OR
10/20/20 Carolina Jarquin
Date of Installation thorization
12/21/20
Today's Date Signature
Taylor Morrison
Company/Customer Name
P.O.BOX 99*HUBBARD,0R 97032*(503)620-7036*FAX(503)624-0599*CCB#71044