Plans
A I B I C I D I E I F I G I H _ - AERIAL VIEW ELECTRICAL NOTES GENERAL NOTES __ REC 'IED 1. WHERE ALL TERMINALS OF THE 1. PRIOR TO THE COMMENCEMENT OF ANY _ ,_ t 3 0 021 DISCONNECTING MEANS MAY BE WORK, THE CONTRACTOR SHALL NOTIFY ENERGIZED IN THE OPEN POSITION, A THE DESIGNER OF ANY DISCREPANCIES CITY OF TIGARD SIGN WILL BE PROVIDED WARNING OF WITH THE DESIGN IN ANY CAPACITY. BUILDING DIVISION THE HAZARDS. (PER ART. 690.17) ESPECIALLY RECOMMENDATIONS, CODES, :,. 2. EACH UNGROUNDED CONDUCTOR OF OR REGULATIONS & RULES OF THE ' THE MULTIWIRE BRANCH CIRCUIT WILL AUTHORITY HAVING JURISDICTION, WHICH BE IDENTIFIED BY PHASE AND SYSTEM. SUPERSEDED THE NEC. (PER ART. 210.5) 2. ALL DIMENSIONS TO BE VERIFIED BY -- - - 3. A NATIONALLY RECOGNIZED TESTING CONTRACTOR PRIOR TO COMMENCEMENT 4� . LABORATORY SHALL LIST ALL OF WORK. .. t, EQUIPMENT IN COMPLIANCE WITH 3. CONTRACTOR IS RESPONSIBLE FOR ALL KKlAr ARTICLE 110.3. SAFETY PRECAUTIONS, OSHA } r ' 4. ALL WIRES SHALL BE PROVIDED WITH REQUIREMENTS ETC. FOR THE SITE, N N y I STRAIN RELIEF AT ALL ENTRY POINTS INCLUDING EXISTING SITE HAZARDS. INTO BOXES AS REQUIRED BY UL LISTING 4. SYSTEM IS GRID INTERACTIVE/INTERTIED LIABILITY f 5. MODULE FRAMES SHALL BE GROUNDED VIA A UL LISTED POWER-CONDITIONING AT THE UL-LISTED LOCATION PROVIDED INVERTER. The City of Tigard and its a* _ BY THE MANUFACTURER USING 5. SYSTEM HAS NO ENERGY STORAGE OF _ —employees shall not be �. UL-LISTED GROUNDING HARDWARE. ANY KIND, OR UPS. responsible for discrepancie Approved plan 6. MODULE FRAMES, RAIL, AND POSTS 6. ALL SOLAR MOUNTING FRAMEWORK TO `. - �. SHALL BE BONDED WITH EQUIPMENT BE GROUNDED. which may appear herein. -' �bafl be on fob s�- GROUND CONDUCTORS AND GROUNDED 7. FOLLOW MANUFACTURERS SUGGESTED AT THE MAIN ELECTRICAL PANEL. INSTALLATION PRACTICES AND WIRING ,_,^ 7. THE DC GROUNDING ELECTRODE SPECIFICATIONS. co CONDUCTOR SHALL BE SIZED 8. ALL WORK TO BE IN COMPLIANCE WITH RESIDENCE PHOTO ACCORDING TO ARTICLE 250.166E & THE INTERNATIONAL BUILDING CODES. 690.47. (IBC) ,\<%.% � PROfiFSj, 9. ALL ELECTRICAL WORK TO BE IN ��� \\G I N f f, /py COMPLIANCE WITH THE NATIONAL - - 4, C. y ELECTRIC CODE (NEC). . > - `" VALIDITY OF PERMIT F ,-- THE ISSUANCE OF A PERMIT ck¢ Y BASED ON CONSTRUCTION .,,-,0 4N t1ti /7- DOCUMENTS AND OTHER I t OFFICE COPY �,a� so_� DATA SHALL NOT PREVENT 41. }4a 1x..M ` Q3/26/2021 THE CODE OFFICIAL FROM F EXPIRES: 06/30/23 REQUIRING THE CORRECTION - STRUCTURAL ONLY OF ERRORS. ORSC 105.4 SHEET INDEX i : PV 1 COVER PAGE PV 5 MOUNTING DIAGRAM PV 2 SITE PLAN PV 6 PLACARD OF SCE COPY ` PV 3 ELECTRICAL DIAGRAM CjI CUT SHEETS ATTACHED CI - t. PV 4 CHIKO MOUNTING RF.VTPWRD F rl tt AATCE DRAWN BY DRAWING SCALE Approved: { CIN THIS PACKET AND SUBIDENTIAL-THE OSEQUEINON T CUOTSHEIETSD ARC DESIGNCUSTOM OTC: [ ]_ /Z f SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER Brian Thorpe DATE: Permit g,,,• =f%.��+���s'=4�Z0f I � ti"-j� �'r,e ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 3/25/2021 Address: `532t6 S� /�V'L-- SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 THE RECIPIENT'S ORGANIZATION, EXCEPT IN Suite #: CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 15328 SW Hudson Ave Tigard, OR, 97224 PAGE# By: A- Date: L9/1/i., RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 1 CONSENT FROM SOLGEN POWER. A I B I C I D I E I F I G I H N INDEX: SYSTEM SIZE DC:7.44kW TRUSS SPACING: 24" O.C. SYSTEM SIZE AC:6.00kW I a id t i I k �' E NUMBER OF MODULES:24 TRUSS SIZE: 2" x 4" 'f S © MODULE TYPE:ZSHINE ZXM6-60-310/M _ O 5 - TT INVERTER: Hoymiles Series MODULES T N N ❑ UTILITY METER T \ ❑ ❑ ❑ o MAIN SERVICE T — /if COMBINER BOX \ ❑ COMP. AC DISCONNECT SHINGLE / ❑ ❑ I M _ // E.. A x \ , \ , \ , _ . \ , <c•0.0 PROFES_ \ \ ck. ',,,,i_ggsfAii--'- 1— 'X e SOLAR OFFSET' I 3/26/2021 CIRCUIT 1 I//4 EXPIRES: 06/30/23 CIRCUIT 2K \\I , STRUCTURAL ONLY DRAWN BY: DRAWING SCALE: CONFIDENTIAL-THE INFORMATION CONTAINED ARC 3/32" = 1' 0" IN THIS PACKET AND SUBSEQUENT CUTSHEETS Brian Thorpe DESIGN SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER DATE: ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 3/25/2021 C:\Users\Collin\Desktop\CAD files\solgen power b(rgb).png SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 THE RECIPIENT'S ORGANIZATION, EXCEPT IN 15328 SW Hudson Ave Tigard, OR, 97224 PAGE# CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 PV 2 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. A I B I C I D I E I F I G I H LOAD CALCS-TOTAL AMPS AVAILABLE MAX AC OPERATING CURRENT CALCS BUS RATING 120% TOTAL MAIN BREAKER MAX BREAKER SIZE #OF MICROINVERTERS MAX OUTPUT CURRENT MAX AC OPERATING CURRENT 200A X 1.2 = 240 - 200A = 40A - 24 x 1.04 = 24.96A COMBINER BOX PANEL SIZE CALCS `— CIRCUIT# NUMBER OF NUMBER OF NORMINAL OUTPUT TOTAL 125% BREAKER BREAKER SIZE BREAKER SIZE CALCS MODULES MICROINVERTERS CURRENT IN AMPS AMPS CIRCUIT 1 12 12 x 1.04 = 12.48 x 1.25 = 15.60 = 20A MAX AC OPERATING CURRENT 125% TOTAL BREAKER SIZE CIRCUIT 2 12 12 x 1.04 = 12.48 x 1.25 = 15.60 = 20A 24.96A x 1.25 x 31.20A = 40A UTILITY METER(E) — NOTES: 1. 200A UTILITY METER GLOBE ONLY.(EXISTING) O1IM)2. 200A LOAD CENTER.(EXISTING) TO UTILITY 3. 60A RATED NON-FUSED AC DISCONNECT INSTALLED GRID(E) WITHIN 10'OF UTILITY METER.(NEW) 4. 125A RATED COMBINER PANEL.(NEW) ALL CONDUIT SIZES ARE MINIMUM SIZES (N ALL WIRE SIZES ARE FOR COPPER WIRE N (2)8 AWG 3 (2)8 AWG EXISTING (1)8 AWG EGC (1)8fAIN AWG EGC WIRE SERVICE PANEL(E) _ q • - 4 I I 200E /-7/ MAIN SERVICE DISCONNECT(E) • • a.coCIRCUIT#1 - 12 ZSHINE ZXM6-60-310/M . co MODULES WITH HOYMILES MI-250 MICRO INVERTERS ,, „, (2)8 AWG �8.O (1)8 AWG EGC _ 1 — `12 • . •N `2 J ` �� a� I/ I - 40A LOAD-SIDE 1 —' _ _ (2)12 AWG SOLAR OCPD / • • • (1)8 AWG EGC (Opposite end of the main disconnect K-----.... ----k. J on the busbar-NEC 705.12(B)(3) .1- CIRCUIT#2- 12 ZSHINE ZXM6-60-310/M MODULES WITH HOYMILES MI-250 MICRO INVERTERS (I 21 . . • `2J `�i _ (2)12 AWG • • • —n, (1)8 AWG EGC cn K-----.. DRAWN BY: DRAWING SCALE: CONFIDENTIAL-THE INFORMATION CONTAINED ARC NOT TO SCALE IN THIS PACKET AND SUBSEQUENT CUTSHEETS Brian Thorpe DESIGN SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER DATE: ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 3/25/2021 C:\Users\Collin\Desktop\CADfiles\solgen powerb(rgb).png SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 THE RECIPIENTS ORGANIZATION, EXCEPT IN 15328 SW Hudson Ave Tigard, OR, 97224 PAGE# CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 P\/ 3 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. A I B I C I D I E I F I G i H r 5.5 rh 1 3.4' --„ 7 0.67'' a i J 1 .4„ (A) 6'' . . . . . . 3 , . . _. ' SOLAR PANEL I ROOFING soL FEET — AMIN lull...1 FLASHING 7# Rail N - � N 1 6: IIIIIhh M W _ 14' Mount to Existing Rafters STRUCTURAL NOTES: 4 4' 4' 1. TOTAL WEIGHT(MODULE&RAIL): 1105 LBS . 2. RAIL WEIGHT: 137 LBS 3. MODULE WEIGHT: 968 LBS Mid Clamp End Clamp 4. DISTRIBUTED WEIGHT: 2.49 PSF tQ tsRO�£S J . 44 yGINt R SF /p , — ) ( 1 11 Laa. i * �_ . `Grounding Lug -,_ i I z _y N. I (A OR3/26/2021 ���"' EXPIRES: 06/30/23 STRUCTURAL ONLY DRAWN BY: DESIGN CONFIDENTIAL-THE INFORMATION CONTAINED ARC IN THIS PACKET AND SUBSEQUENT CUTSHEETS Brian Thorpe DATE: SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER w ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 3/25/2021 I' C:\Users\Collin\Desktop\CAD files\solgen power b(rgb).png SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 PAGE# CO RECIPIENT'S NS O THE ALEIAN, USE IN 15328 SW Hudson Ave Tigard, OR, 97224 CONNECTION WITH THE SALE AND USE OF THE P: 509 931-1663 PV 4 RESPECTIVE EQUIPMENT,WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. A I B I C I D i E I F I G H __ ___ C 30'-6" l l • 1 • 18'-8" 1 ' Q 1 0 O 1111...11111 prr ; -- N 0 0 0 0 0 + N I! „ .• i ! 21-7" o o a PV MODULE 10'-7" MOUNTING FEET / - ROOF 1 / — I ■ TI LT:26° j AZIMUTH:180° / ROOF 2 TILT:26° CHIKO#7 RAIL / AZIMUTH:90° co ' I / 1 i I W illiallilillt 2 MOUNTINGADIAGRAM � hili STRUCTURAL NOTES: 1. 48" MAX SPAN OF RAIL TO DISTRIBUTE WEIGHT 20-9" I OVER SUPPORT OF TRUSSES 1111611 It , 111511 d 2. MOUNTING FEET ARE IN APPROXIMATE LOCATION. { 3. MOUNTING FEET SHOULD BE STAGGERED AS SHOWN IN DIAGRAM PR c : ROOF 3 '\('S D �FF.Ss/Q —aWNE 0 !uI!iriiliillll L AZIMUTH:180° ' T-- L 44, j Lo cn 'reVOR JJ� 3/26/2021 1 MOUNTING DIAGRAM EXPIRES: 06/30/23STRUCTURAL ONLY DRAWN BY: DRAWING SCALE: CONFIDENTIAL-THE INFORMATION CONTAINED ARC 21/128" = 1'-0" DATE: IN THIS PACKET AND SUBSEQUENT CUTSHEETS Brian Thorpe DESIGN SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 3/25/2021 C:\Users\Collin\Desktop\CAD files\solgen power b(rgb).png SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 THE RECIPIENT'S ORGANIZATION, EXCEPT IN 15328 SW Hudson Ave Tigard, OR, 97224 PAGE# CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 PV 5 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. A I B I C I D I E I F I G I H T CAUTION Main Panel Enphase Combiner Soladeck & Junction Boxes AC Disconnect PHOTOVOLTAIC SYSTEM i POWER TO THIS BUILDING IS SUPPLIED FROM THE ,CAUTION PHOTOVGt.TAIC POWER SOURCE AAC OISCIAINEC►� FOLLOWING SOURCES WITH DISCONNECTS RELECTMICSYSr�� CON`,E{:-`u' a CAUTION OPERATING AC VOLTAGE SOLAR CIRCUIT WARNING LOCATED AS SHOWN: E _.F, IIIIIIIIIIIIIIv .,... _ wa DPERAI NlGAC OUTPUT CURRENT 15328 SW Hudson Ave Tigard,OR,97224 �, —` A� a. Conduit: Every 101 SOLARPVSYSTEM E:� 10 Ebal,�k-1.. EQUIPPED WITH 5O�IKES TIu ,%G, ML RAPID SHUTDOWN ,, -`., E E'r,',`. A CAUTION .-a'11 11%1"#VV.0 fl I PHOTOVOLTAIC SYSTEM 44 r: wr�ur+e,nun 9; III► I COMBINER PANEL SOLAR CIRCUIT (" PV DISCONNECT PKICSVJAALIWERSCARCE yl N 11111.111111.1 DO NOT ADD LOADS T UTILITY METER MAIN SERVICE PANEL ..,, x1 �: 4' PHOTOVOLTAIC SYSTEM , '0 iifr EQUIPPED WITH '° "" 1,1: RAPID SHUTDOWN _ RAPID SHUTO`NN SOLAR PV ARRAY WITH s 4 ilEf ftl - ,F�, 1 — �_____ � SWITCH FOR — 1E1 SHl1TDfli"1N 3 MICROINVERTERS Viral;OR I A WARNING A Sa_ARPI/SYSTEM ROOF MOUNTED ,� SOtPVSYS7EM SOLAR PV SYSTEM • AC MICRO INVERTERS x �, EQUIPPED WITH LOCATED ON ROOF PV SYSTEM kWh Meter I ' RAPID SHUTDOWN __ UNDER MODULES ._ PHOTOVOLTAIC SYSTEM I co kWh METER W 1 1 ELECTR -SOCK HA:', 1 rilkAfriA.I saw +u`uv rusiircwo TIv nrra IL TERMINALS ON THE LINE.AI — � xN�A1r7ARElA Y Inside Panel LOAD SIDES MAY 6t EN£*GIcE._, — IN THE OPEN POSITION z x SOLAR PV BREAKER_' 3 SNEAKER:S SACOED s DO NOT RELOCATE i s d- A a i t a Y 6 "x6 " i Lo ol Y i I DRAWN BY DESIGN CONFIDENTIAL-THE INFORMATION CONTAINED ARC IN THIS PACKET AND SUBSEQUENT CUTSHEETS Brian Thorpe SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER DATE: w ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 3/25/2021 I I C:\Users\Coltin\Desktop\CAD files\solgen power b(rgb).png SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 PAGE# CO RECIPIENT'S NWS H THE ALEIAN, USE IN 15328 SW Hudson Ave Tigard, OR, 97224 CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 PV 6 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER.