Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (23)
M EC2020-00748 OFFICE COPY RECEIVED NOV 12 2020 DUCT FITTING SYMBOLS OUTSIDE AIR. (VENTILATION) KEQU I KEM ENTS BUILDING DIVISION ��� Fss, CITY OF TIGARD cD PROF DOUBLE LINE SINGLE LINE DOUBLE LINE SINGLE LINE �' \''�69 9PE 9 NET VENTILATION REQ VENTILATION - - u w �' _ ,��IM I f ROOM AREA AREA OCCUPANCY * PEOPLE OSA RATE AREA OSA RATE TOTAL PROVIDED SYSTEM A ,! OREGON R=D LESS THAN 15' - OFFICE 80 FT2 80 FT2 5 OCC/1000 FT2 = 0.4 5 CFM/OCC = 2.5 CFM 0.06 CFM/FT2 = 6.0 CFM 8.5 CFM 4 CFM FC-1 ao� 1' 5 PIECE ELBOW s ----_____5 - OFFICE 80 FT2 80 FT2 5 OCC/1000 FT2 = 0.4 5 CFM/OCC = 2.5 CFM 0.06 CFM/FT2 = 6.0 CFM 8.5 CFM 4 CFM FC-1 �C,�T f'75 2 15'-30 - OPEN OFFICE 485 FT2 485 FT2 5 OCC/1000 FT2 = 2.43 5 CFM/OCC = 15.16 CFM 0.06 CFM/FT2 = 36.38 CFM 51.53 CFM 62 CFM FC-1 r W. G'R s * PER ASHRAE 62.1-2010 TABLE 6-1 AND 2019 OMSC TABLE 403.3 3.23 OCCUPANT DIVERSITY = 0.93 AR DISTRIBUTION EFF. = 0.8 68.53 CFM 70 CFM FC-1 I ° DECEMBER 31, 20211 R=Ww f , + RADIUS REVISIONS: ELBOW OVER 3O FAN COIL UNIT SCHEDULE u_ 3 I RADIUS ELBOW S 1 r, EXT. MOTOR ELECTRIC HEATER WEIGHT MANUFACTURER MIN OSA RADIUS \-5 DESIG CFM S.P. HP SPEED STEPS KW LBS AND MODEL NO. CFM 4r TURNING ELBOW (RND� �� FC-1 725 0.5" 1/3 HIGH 1 5 92 RUUD RH1T2417STANJA 70 VANES OVER 30' , aa___4 I ' ELEVATION ELEVATION MITER ELBOW I I I 4.-3- NEAT PUiVP UNIT SCHEDULE i FROM ABOVE FROM ABOVE �� j COOL HEATING WEIGHT MANUFACTURER x 6-__114____ B�. OFFSETS DESIG MBH MBH C SEER HSPF LBS AND MODEL NO. ,... F I C E C;O PYle 6"-tf 1 s� s O CITY OF TIGARD„, 11111 _ SUPPLY SUPPLY & 15'MAX HP-1 23.8 22.8 14.0 8.2 145 RUUD RP1424AJ1NA 3 _ REVIEWED FOR CODE COMPLIANCE {- W rt . -w- i RETURN 01 AT 78F DB, 63'F WB ENT. COIL, 95'F OUTSIDE TEMPERATURE _ _ _ _ Appro�cd� ] SCOtt Cruz 5---� S O2 AT 7O'F DB INSIDE TEMPERATURE, 47'F OUTSIDE TEMPERATURE OTS i ] 12'-x- 30' ' 15'MAX "0-] O3 MATCHED WITH FC-1 Permit#: - B _ m�rID ,n o 7 y ,�. Engineer RETURN i +w, a�1� 7510 N.E. VANCOUVER COUVER2 (OR 254-9234SUIT100 t s---p s ■■ Address: VANCOUVER, 98 CAST.N( RECTANGULAR TAP 15'MAX L • "0 "0� EX h AU 5T FAN 5 C H E D U LE �� �`'� � a 1 d W1 TRANSITION Suite#: ■ Y "B" IF TO DIFFUSER DESIG CFM SP MOTOR MANUFACTURER WEIGHT CONVENTS _Am Ey' 1 )-m'1,-?,a OR GRILLE AND MODEL NO. €0wurim- �'T' Date: 20186M1.DING S V+1 I W1 CEF-1 75 0.25" 50 W GREENHECK SP-B90 10 LBS 1O 2O �w�a �a -17 ti. ;1 -TURNING W2 B� � TURNING --1(E -v (V?01■1 W1 VANES W2-41 VANES SUPPLY & 0 PROVIDE WITH BACKDRAFT DAMPER Imrin■■ ■■ 414 SUPPLY & RETURN ® CONTROLLED BY LIGHT SWITCH L"'--- . °'-' J /5 4lir + W2 RETURN W2 i MITER ELBOW BRANCH Heating&Air Conditioning Inc. MITER TEE RECTANGULAR IV EC H AN I CAL CODE NOTES HVAC CONTROLS - "Get it doge the RITE WAY!" VALIDITY OF PERMIT CCB 71242 THERMOSTATS TO BE 7 DAY PROGRAMMABLE WITH NIGHT THE ISSUANCE OF A PERMIT HVAC SYMBOLS SETBACK. MINIMUM DEADBAND FOR THERMOSTATS 5 DEGREE F. E BASED ON CONSTRUCTION PER 6.4.3 OF ASHRAE STANDARD 90.1-2016 DOCUMENTS AND OTHER . • 1 INTERNALLY INSULATED SHEET METAL (SINGLE LINE} DATA SHALL NOT PREVENT • CONTROLS TO VARY THE START-UP TIME OF EACH SYSTEM TO THE CODE OFFICIAL FROM INTERNALLY INSULATED SHEET METAL (DOUBLE LINE) MEET SPACE REQUIREMENTS PER 6.4.3.3.3 OF ASHRAE STANDARD REQUIRING THE CORRECTION 90.1-2016. OF ERRORS.OSSC 105.4 BARE OR INSULATED METAL DUCT (SINGLE LINE) 11 OUTSIDE AIR, EXHAUST AND RELIEF DAMPERS TO COMPLY WITH i { BARE OR INSULATED METAL DUCT (DOUBLE LINE) 6.4.3.4.2 AND 6.4.3.4.3 OF ASHRAE STANDARD 90.1-2016. 0FLEX DUCT (SINGLE LINE) DUCT SYSTEMS - A KEY PLAN ALL DUCTWORK TO BE SEALED AND INSULATED PER 6.4.4.1.2 AND M1 NO SCALE O ROUND DUCT: UP OR DOWN 6.4.4.2.1 OF ASHRAE STANDARD 90.1-2016. 9 I t B BUTTERFLY DAMPER 0&M MANUALS - I-p-1 0&M MANUALS TO BE PROVIDED TO BUILDING OWNER. BDD BACK DRAFT DAMPER CADETLLECTRD COM-PAK�:ALLHEA. MODETER.L OBD OPPOSED BLADE DAMPER 1.--) OAD-1 OUTSIDE AIR DAMPER No.1 ` CS051T W/TFERMOSTAT. t I SD SMOKE DETECTORimiPROVIDE W/ WALL CAN 8 T T S THERMOSTAT: WALL MOUNTED .) l� SENSOR -�Y� 'II HSW HIGH SIDE WALL SUPPLY OR RETURN WALL "1l l� L . LSW LOW SIDE WALL SUPPLY OR RETURN CAP '���77` ECG EGGCRATE GRILLE 6�0 DN TO REi�iIRN PLENUM 0 E t RA RETURN AIR: UP OR DOWN 12x10 AUTOMATIC DAMPER 0 E s OSA OUTSIDE AIR: UP OR DOWN �AR LOUVER ,1 Ecr=t / Q m E t SA SUPPLY AIR: UP OR DOWN 1 ' --).110 AIR VOLUME, CFM I `. 14 LLS 8x8 DIFFUSER NECK SIZE (..)inimm � J C 4W 4- BLOW DIRECTIONS _ ' `-- A-MOUNT ON LD - RB REBALANCE EXISTING DIFFUSER TO THIS CFM ' Q isno OF TOLET ROOM (30)- RELIEF AIR CFM THRU UNDERCUT OF DOOR o-- l WITH SECONDARY LU Z AND FLOW DIRECTION W � ' B . DRAM PAN _W_! � z s G i G GAS PIPING CEF-1 CEILING EXHAUST FAN NO. 1Ci FC-1 FAN COIL N0. 1 / W w cc HP-1 HEAT PUMP N0. 1 CONNECT TO EXISTING 4; N.1.0 U J ° Z CC 0 z=�:r a p 4 sip REMOVE TEMPORARY CAP 8c CONNECT Q EXISTING TO REMAIN r A./ / moo CAP EXISTING ' 1, ' CC © / X60 � Q ® TEMPORARILY CAP EXISTING ; Q Z ('� Q NEW �'� .-. -_ _. . _.. rvpO 1.- ,_ + Q RELOCATE EXISTING / � -- � Q � p >r 4 © REMOVE EXISTING % j � O � p W/ WITH _____I . �. �- 7215U___ Q 16x16__ v a ..,g ' 4 0 CU -FLEXIBLE DUCT (MAX co 10'-O" LENGTH) ~ a SECURE TO STRUCTURE -�- END ROUND OR FLAT "UNITED McGILL,, _ I' 1 NOTE: SIMILAR AT GYP BOARD CEILING EXCEPT DAMPER ROD OVAL DUCT EITHER UNITED McGILL o v BEARING SR(*)TLR REDUCING DATE ISSUED: u HANGER STRAP �, �`-, EX ONLY DOWN TO CONCEALED REGULATOR BOX, YOUNG MODEL SIDE AS SHOWN SR(*)TXL LOLOSS TEE i FLEXIBLE DUCT (MAX LOLOSS 90' CROSS •/ o_ FULL /`_ rte PLOT DATE: o RADIUS Q / SECURE TO STRUCTURE �y \ 10'-O" LENGTH) END rr� V FLAT OVAL DUCT a BEARING SIZES AS SHOWN November 11, 2020 o BEND HANGER STRAP �� 9 E- REQUIRED ��, B III � -,.x-„ %/ % 6 0 CHECKED: L FULL ' t COUPLING B S. Cruz PULL INNER LINER OF FLEXIBLE DUCT RADIUS DISTANCE BETWEEN TAKE- / 1-4:J OFFS TO BE 8 DUCT DIA. ��, DESIGNER: a TIGHT AND SECURE WITH PANDUIT BEND U �/ ��� NOTE: �f • WHERE POSSIBLE SC STRAP REQUIRED -r_ MITERED 90' OTHER ACCEPTABLE �� / _ FITTING & TYPES a o ROUND DUCT SIZES » - 10"O CAD OPERATOR: �, 2" COLLAR f �I B ELBOW WITH -� � � 1 Q, 12 MINIMUM j° PANDUIT STRAP - PULL VANES UNITED McGILL o SHEET METAL CAN OF METAL 'INNER AND OUTER LINES AS SHOWN -"0SR{*)TXLR SC 41,1 12" MIN. EXTENSION REDUCING LOLOSS - _ - PARACLETE JOB: - DUROCT TIGHTEN NSECURELY. STRAP AND Y -BRANCH BEFORE FLEX DUCT 90' CROSS O S: 20186 12" MIN SECURE GRILLE TO CEILING CONNECTION t INSTALL IN EXTERIOR WALL r SYSTEM INSULATIONSECURE DIFFUSER TO CEILING AND PROVIDE A MINIMUM OF rn / . ---- �F SYSTEM '`LOW VELOCITY FLEX DUCT 10'-0" ABOVE EXHAUST -7:1 _11 . TYPICA WALL CAP. L LOW VELOCITY DUCT • 0 TOP CONNECTION AT GRILLE DIFFUSER INSTALLATION CONSTRUCTION DETAILS TI I--IVAC FLOOR PLAN NO SCALE NO SCALE SCALE: NONE 1/4" = 1'-0" CITY OF TIGARD DRAWINGS DONE FOR O Approved byPlanning RITE WAY HEATING 2 Date: << NI �2b Initials: