Report 'K202 -CO2q eteOFFICECOPY IFF E COPY cv3 t 6h5cj TRANS' Submittal RECEIVES CITY OF TIGARD Prepared For: Date: February 17, 2021 All Bidders BUILDING DIVISION Job Name: SGH 3757-Washington Square Trane U.S. Inc. is pleased to provide the following submittal for your review and approval. Product Summary Qty Product 1 BCXD Blower Coil- Direct Drive (BCXD) Nick Lazar on Behalf of The attached information describes the equipment we propose to furnish for this project,and is submitted for your approval. Monica Sunderhaus-Trane National Accounts 2300 CityGate Drive Product performance and submittal data is valid fora period of 6 Columbus,OH 43219 months from the date of submittal generation.If six months or Cell: (614)980-5103 more has elapsed between submittal generation and equipment Monica.Sunderhaus@trane.com release,the product performance and submittal data will need to For questions on this document call or email be verified.It is the customer's responsibility to obtain such verification. natcolsOtrane.com Document Scope is based upon Mechanical Plan set dated 01.29.21, If there is a more current plan set,please inform Trane and the proposal and submittal can be updated appropriately ©2021 Trane All rights reserved SGH 3757-Washington Square Submittal 021721.docx SGH 3757-Washington Square February 17,2021 Tag Data-BCXD Blower Coil -Direct Drive(BCXD) (Qty: 1) Item Tag(s) Qty Description Model Number Al AHU-1 1 BCXD Blower Coil - Direct Drive BCHD036E1M0A2N04Z2050ACC0100000 (BCXD) 000K00000 Product Data -BCXD Blower Coil -Direct Drive(BCXD) Item:Al Qty: 1 Tag(s): AHU-1 Horizontal Configuration Unit Size 36; 3 Ton 208/60/3 Matte Faced Insulation 1" Motor, drive &control box on Same Side as Coil &Drain pan Connection Polymer Drain pan- Left Hand Coil &Drain pan Connections 6 Row High Capacity Hydronic Coil 1 Horsepower Electric Reheat 5.0 kW, 2— Stage Heater 24 Volt Magnetic Contactors Heat Int-lock Non-Fuse Disc. &Htr. Fuse 2" Pleated MERV 13 Throwaway Filter Customer Supplied Terminal Interface Condensate Overflow&Low Limit Switches Honeywell Vision Pro Thermostat-TH8321WF1001 (Field Installed) Remote Room Sensor- C7189U1005 (Field Installed) Performance Data -BCXD Blower Coil -Direct Drive(BCXD) Tags AHU-1 Design airflow(cfm) 1400 Fan speed (rpm) 1537 Total cooling capacity (MBh) 48.70 _ Sensible capacity(MBh) 36.54 Cooling EDB (F) 80.00 _ Cooling EWB (F) 67.00 Cooling LDB (F) 56.07 Cooling LWB (F) 55.85 Cooling ent fluid temp(F) 47.00 Cooling leaving fluid temp (F) 60.98 Cooling flow rate(gpm) 6.95 Cooling delta T(F) 13.98 Cooling fluid PD (ft H2O) 10.49 Fluid type Water Fluid velocity(ft/s) 3.48 APD (in H2O) 0.885 _ Cooling face velocity(ft/min) 525 Auxiliary heat type Electric Reheat Aux EAT(F) 60.00 Aux LAT(F) 71.29 Aux total capacity(MBh) 17.08 Unit length (in) 33.720 Unit width (in) 40.000 Unit height(in) 18.000 Installed weight(Ib) 187.4 Rigging weight(Ib) 177.4 Elevation (ft) 299.00 ESP (in H2O) 0.600 TSP (in H2O) 1.771 Motor heat calculation Ignore Piping pkg PD (ft H2O) 0.00 Equipment Submittal Page 3 of 17 SGH 3757-Washington Square February 17,2021 Tags AHU-1 Min circuit ampacity(A) 23.12 Basis of selection Cooling Maximum overcurrent protection (A) 25.00 Main coil type Hydronic Inlet-63 Hz (dB) 77 Inlet- 125 Hz (dB) 81 Inlet-250 Hz (dB) 79 Inlet-500 Hz (dB) 64 Inlet- 1 kHZ (dB) 63 Inlet-2 kHZ (dB) 62 Inlet-4 kHZ(dB) 58 Inlet-8 kHZ(dB) 54 Casing-63 Hz(dB) 70 Casing- 125 Hz(dB) 73 Casing-250 Hz(dB) 70 Casing-500 Hz(dB) 63 Casing - 1 kHZ(dB) 61 Casing-2 kHZ(dB) 51 Casing -4 kHZ(dB) 47 Casing -8 kHZ(dB) 44 Discharge-63 Hz(dB) 86 Discharge- 125 Hz(dB) 87 Discharge-250 Hz(dB) 83 Discharge-500 Hz(dB) 78 Discharge- 1 kHZ(dB) 79 Discharge-2 kHZ(dB) 75 Discharge-4 kHZ(dB) 74 Discharge-8 kHZ(dB) 70 Motor Max BHP (hp) 1.029 ECM -brake horsepower(hp) 0.790 Full load amps(A) 4.60 Outlet velocity(ft/min) 1643 Inlet plus casing -63 Hz(dB) 78 Inlet plus casing - 125 HZ(dB) 83 Inlet plus casing-250 Hz(dB) 80 Inlet plus casing-500 Hz(dB) 68 Inlet plus casing - 1 kHz (dB) 68 Inlet plus casing-2 kHz(dB) 63 Inlet plus casing-4 kHz(dB) 58 Inlet plus casing-8 kHz(dB) 54 ECM -service factor() 1.30 Equipment Submittal Page 4 of 17 SGH 3757-Washington Square February 17,2021 Mechanical Specifications -BCXD Blower Coil -Direct Drive Item: Al Qty: 1 Tag(s): AHU-1 BCHD General The product line consists of a horizontal air handling unit and optional mixing box.Air-handling airflow data is certified in accordance with AHRI standard 430. The unit is UL listed to U. S. and Canadian safety standards and complies with NFPA 90A. Air handlers consist of a hydronic and/or DX coil, drain pan, and centrifugal fan with motor in a common cabinet. Motor location and coil connections are independent for the same or opposite side location.Air handlers are provided with knockouts in all four corners for installing the unit suspended from the ceiling with threaded rods. Unit and accessories are insulated with 1" 1.5 lb/cu.ft density fiberglass insulation. 1"foil faced insulation is also available. Large motor access panels are provided on both sides of the unit and accessories. Casing Casings(structural components)are constructed of 18-gauge galvanized steel, insulated with 1" 1.5 lb/cu. ft density fiberglass fire resistant and odorless glass fiber material to provide thermal and acoustical insulation. Fan housing sides are directly attached to the air handler top and bottom panels strengthening the entire unit assembly. Coil access panels are located on both sides of the air handler and allow easy removal of the internal coils and drain pan. Main access panels provide generous access to the fan and motor from both sides of the air handler. Matt Faced Insulation The interior surface of the unit casing is acoustically and thermally lined with 1" 1.9 lb/cu. ft R-Value of 4.2 density glass fiber with high density facing.The insulation is UL listed and meets NFPA-90A and UL 181 standards. Coil#1 Hydronic Cooling Coils Cooling coils are four or six row chilled water. All water coils are 12 fins per inch. All water coils use highly efficient Trane Delta Flo, Type H aluminum fins, mechanically bonded to seamless copper tubes. All coils are specifically designed and circuited for water use. All coils are factory tested with 450.00 psi air under water. Maximum standard operating conditions are 300.00 psi at 200.0 F. Sweat type connections are standard. Coil performance data is in accordance with the current edition of AHRI Standard 410. Electric Heat Stages Factory provided and mounted, UL recognized resistance open-wire heater with a disc-type automatic thermal primary safety device. Two stages of control. Single point power connection to the unit is provided. Optional line fuses and a door interlocking disconnect switch are available. Magnetic Contactors A 24 volt electric heater contact for use with Thermostat Control Interface. Reset Backup Protection Secondary Manual Reset Backup Protection is provided. Disconnect Switch A factory provided disconnect switch with an interlocking door on the heater control panel. Line Fuse A safety fuse located in the electric heater's line of power to prevent power surge damage to the electric heater. Unit Fan The fans are DWDI (double width double inlet)forward curved centrifugal blower type. The fans are direct drive mounted directly to the motor shaft. All fans are dynamically balanced. All air handlers have a single fan. Electronically Commutated Motors (ECM) -Three Phase All motors are brushless DC (BLDC)electronically commutated motors(ECM)factory programmed and run tested in assembled units. The motor controller is mounted in a control box with a built in integrated user interface and LED tachometer. If adjustments are needed, motor parameters can be adjusted through momentary contact switches accessible without factory service personnel on the motor control board. Motors will soft ramp between speeds to lessen the acoustics due to sudden speed changes. Motors can be operated at three speeds or at variable speed with factory supplied or field supplied controllers. The motor will choose the highest speed if there are simultaneous or conflicting speed requests. All motors have integral overload protection with a maximum ambient operating temperature of 130.0 F and use permanently sealed ball bearings. Motors can operate at plus or minus 10 percent of rated voltage on all speed settings. Equipment Submittal Page 5 of 17 SGH 3757-Washington Square February 17,2021 2" Pleated Throw-Away Merv13 Filter The units are equipped with 2"flat pleated media filters and a Merv13 rating based on ASHRAE Standard 52.2. A Merv13 rating requires 90%efficiency on 1-3 micron particles and greater than 90%efficiency on 3-10 micron particles when tested in accordance with ASHRAE Test Standard 52.2.This Merv13 exceeds the ASHRAE 62.1-2007 minimum requirements. Additionally this filter meets efficiency standards for obtaining LEED points under IEQC5. Polymer Drain Pan The drain pan is noncorrosive and double-sloped to allow condensate drainage. The drainpan construction is polymer. Coils mount above the drain pan, not in the drain pan - thus allowing the drain pan to be fully inspected and cleaned. The drain pan can also be removed for cleaning. The drain pan connections are unthreaded 3/4" schedule 40 PVC for solvent bonding. The main drain connection is at the lowest point of the drain pan.An auxiliary drain connection is provided on the same side as the main connection. Customer Supplied Terminal Interface(CSTI) The customer supplied terminal interface (CSTI)is a pre-wired control offering of selected control components. This option intended to be used with a field-supplied, low-voltage thermostat or controller and field supplied temperature sensors. The control box contains a relay board which includes a line voltage to 24-volt transformer and disconnect switch (for non-electric heat units). Selected components are wired to a low-voltage terminal block and are run- tested, so the only a power connection and thermostat/controller connection are needed to commission the unit. Condensate Overflow Sensor This option provides an output that indicates when the drain pan is in danger of overflowing with condensate. This condition is indicated when the float switch rises to 50%of its travel and the normally closed output opens. The float switch is factory-wired to a terminal block for connection to a field supplied controller. When wired to the CSTI, the switch does not de-energize the unit when open position occurs. This is a dry contact only and sequence of operation of unit when this condition is reached is the responsibility of the field provided controller or thermostat. Freezestat A freezestat is a normally closed protection device that opens the circuit when the entering air temperature to the main coil is below a specific trip temperature. This circuit will not close until the entering air temperature exceeds a specific release temperature. Equipment Submittal Page 6 of 17 SGH 3757-Washington Square February 17,2021 Dimensional Drawings -BCXD Blower Coll -Direct Drive Item: Al Qty: 1 Tag(s): AHU-1 F34---T-Tr 0 07i8"KNOCKOUTS FOR HANGER RODS(TOP AND BOTTOM OF UNIT}4X 3314' 1" TOP VIEW MOTOR ACCESS PANEL - FRONT DISCHARGE BACK INLET 1 sue- r1511116' '1i1B"-1 DUCT OPENWG 1- - DU CT OPENING a 139196' Isla 1i16' FRONT VIEW FHLT ER ACCESS PANEL 33 3/4' RIGHT VIEW NOTES I ACCESS PANELS ARE LOCATED ON BOTH SIDES OF THE UNIT TO PROVIDE ACCESS TO THE UNrr'S INTERNAL COMPONENTS. 2.CONTROL BOX IS FACTORY MOUNTED ON DRIVE SIDE AND PROVIDED WITH 7!8"DIAMETER KNOCKOUTS FOR FIELD WIRING. 3.ARROWS INDICATE THE DIRECTION OF AIRFLOW Equipment Submittal Page 7 of 17 SGH 3757-Washington Square February 17, 2021 Dimensional Drawings - BCXD Blower Coil -Direct Drive Item: Al Qty: 1 Tag(s): AHU-1 314"(SCHEDULE 40 PVC)MAIN DRAIN CONN 3I4"(SCHEDULE 4D PVC)AUXILIARY DRAIN CONN MM a 2 1/8" I I t+2 11 7116" 13 7116" - LEFT VIEW NOTES 1.ALL DIMENSIONS ARE SHOWN FROM THE BOTTOM REAR CORNER OF ON(F. 2.STU HOOTS PROTRUDE 2 118"FROM EXTERIOR CASING OF UNIT 3.ARROW INDICATES THE DIRECTION OF AIRFLOW 4.DRAIN CONNECTIONS ARE UNTHREADED. Equipment Submittal Page 8 of 17 SGH 3757-Washington Square February 17,2021 Dimensional Drawings - BCXD Blower Coil -Direct Drive Item: Al Qty: 1 Tag(s): AHU-1 NOTES: 1.WEIGHT OF BASIC UNIT INCLUDES ONLY CABINET,FAN, AVERAGE DRIVE,WIRING AND AVERAGE FILIFR. 2.WEIGHT OF STEAM COIL MODULE INCLUDES ONLY CABINF1 WIT HAVERAGE FILTER. 3.BEFORE PREPARING ANY UNIT OR ACCESSORY MODULE FOR LIFTING, ESTIMATE THE APPROXIMATE CENTER OF GRAVITY AND TEST LIFT THE UNIT OR ACCESSORY MODULE TO DETERMINE BALANCE AND STABILITY USE PROPER RIGGING METHOD SUCH AS STRAPS,SLINGS OR SPREADER BARS FOR PROTECTION AND SAFETY BEFORE HOISTING THE UNIT OR ACCESSORY MODULE. CONDITIONS4.DD NOT Lff F UA NS OR ACCESSORY MODULES IN WINDY EONL OFAILURE ABOVE OYN 110 PERSONNEL.FAILURE TO PROPERLY e LIFT UNIT OR ACCESSORY MODULE COULD RESULT IN DEATH.SERIOUS INJURY,EQUIPMENT DAMAGE OR PROPERTY-ONLY DAMAGE. 5.DO NOT RIG OR LIFT UNITS OR ACCESSORY MODULES WITH FORK LET FORKS. 6.ASSEMBLY OF THE UNIT MUST BE PERFORMED AT THE INSTALLATION SSITE.ALWAYS RIG UNITS AND ACCESSORY MODULES AS SHIPPED FROM THE IS01 VIEW FACTORY. UNIT,COIL&ACCESSORY MODULE WEIGHTS ELECTRIC ANGLED ANGLED FILTER BASIC UNIT COIL 1 DRY COIL I WET COIL2 DRY COIL 2 WET MOTOR MIXING BOX HEATER FILTER BOX MIXING BOX • 10450 36.16 46.1 lb 17.0 II 1281b FILTER ACCESS STEAM COIL STEAM COIL STEAM COIL MODULE MODULE DRY WET UNIT SIZE SERVICE CLEARANCE 36 37- ri 1502 VIEW Equipment Submittal Page 9 of 17 SGH 3757-Washington Square February 17,2021 Dimensional Drawings -BCXD Blower Coil -Direct Drive Item: Al Qty: 1 Tag(s): AHU-1 NOTES: ALL DIMENSIONS ARE IN INCHES HORIZONTAL NON-ELEGTIC HEAT SLOWER COIL ALL COIL CONNECTIONS ARE SWEAT STYLE WEIGHT OF BASIC UNIT INCLUDES C.413INET, FAN, WIRING AND AVERAGE FILTER, IT DOES NOT INCLUDE COIL MOTOR OR SHIPPING PACKAGE. PLEASE REFER TO CATALOG FOR MOTOR WEIGHTS. F F ADD TO BASIC UNIT WEIGHT, 7 LEIS FOR WEIGHT OF CONTROL BOX CONTROL BOX FACTORY MOUNTED OEN MOTOR SIDE, 1.00 M111111 ..1111.=1 HTG & CLG COILS 2.9 00 1.00 0.875 POWER CONNE50071 ON OPPONFIE SIDE MI D5 100 58 K14009007 FOR HANGER 7 RODS. TOP 4e BOTTOM OF UNIT ACCESS PANELS ALL COIL CONNECTIONS I-4,-1 53 ONLY FOR \OCATED IN THIS AREA WIRELESS ZONE \FILTER ACCESS SENSOR RECEIVER p 550r -95 1 ET1111 I 0 875 H 1 I FOYER Frr r 111 A = UNIT CONTROL BOXC°NNECTI°4 550.X 5 3 05 I IL 24 11 IIIII 111111114.1111 - 121.11 4.2' 2,15 1„50 r 111. 2 G -1.0095 19 NOMINAL SCH 40 PVC MAIN & AUXILIARY DRAIN CONN G G 4 UNTHWL A 5CDE F ...I K P R S T N1c4114 SIZE R.H. LH. R.N. Li-I. 12 14.00 24.00 31.15 12.09 1500 10.56 7.47 0.55 3-00 11.4213_42 9.42 11.42 4.20 8.24 9.00 5.75 135 .99 4,26 840 18 14.00 28.00 31.15 12.09 22.00 10.56 7.47 0.55 3.00 11 42 13.42 9.42 11.42 4.20 10.24 9.00 5.75 3.42 .99 4.19 64 0 24 18.00 28.00 33.72 16.59 22.00 1337 9.04 1.30 3.00 11,47 13.42 9.42 11.42 6.20 9.68 9.00 5.75 2.73 1.17 4,09 89 6 36 18 00 413 00 33 72 16 09 34.00 13.57 9.04 1.30 3 00 11 42 13.42 9.42 11.42 6.20 15,68 9.00 5.75 8.64 1.01 4.19 104,8 54 22,00 40.00 41,57 20,09 34 30 13.58 12.57 0.72 3.00 11.42 13.42 9,42 11.42 7.43 13.72 11,00 7,27 6.87 5 01 4.12 129.9 72 22.00 48.00 41.57 20.05 4050 13,58 12.57 0.72 4 00 11.42 13.42 9.42 11.42 743 17.72 11,00 7,27 15.87 501 4.19 142.0 90 28,00 46.00 43,94 29 09 40 Do 13.58 12.57 1,813 4.00 12 79 14.79 10,79 12.79 8.24 47.72 11.25 11,64 15.92 11.14 4.14 162,8 Equipment Submittal Page 10 of 17 SGH 3757-Washington Square February 17,2021 Fan Curve- BCXD Blower Coil -Direct Drive Item: Al Qty: 1 Tag(s): AHU-1 I Fan Details Unit Size 36 Operating Brake 0.790 hp Power Operating Airflow 1,400:cfna Altitude 299.O0 ft Operating Static 1.771 in H2O Design Temp. 80.00 F Pressure Operating RPM 1,537 rpm' Slit- a`4 40 99 99— ,; ,; 4A9W IiiRa\ '''.*:4\9+9090 aura as ,, a e S , AI �� ✓ q4 S l S y � e 9-99K 90,9 Isdi { t',14.141 z46u ,:1)00 rffow Kfr9' Equipment Submittal Page 11 of 17 SGH 3757-Washington Square February 17,2021 Accessory-BCXD Blower Coil -Direct Drive Item: Al Qty: 1 Tag(s): AHU-1 MAIN UNIT COIL CONNECTIONS RETURN 11/B' SUPPLY 11/13- AIR FLOW SUPPLY • RETURN • 11 5/8" 8518" 71/4" - 12 3/4' - BOTTOMREAROFUNIT - NOTES: 1 PICTORIAL HEADER STUBOUT LOCATIONS RELATIVE TO EACH OTHER MAY NOT BE ACCURATE. 2.LOCATING OMEN SIONS HAVE PLUS/MINUS 2" TOLERANCE. 3.FOR UNITS WffH AFILTER ACCESS MODULE,ADD 7 316' TO HORIZONTALDIMEN SIGNS SHOWN. 4.PIPING CONNECTIONS ARE SPECIFIED AS OUTSIDE DIAMETER(0 ) Equipment Submittal Page 12 of 17 SGH 3757-Washington Square February 17,2021 Accessory-BCXD Blower Coil -Direct Drive Item: Al Qty: 1 Tag(s): AHU-1 Figure 4. Electric heat dimensions Mounting flange top and bottom unit sizes 12, 18,24,36 Top only unit sizes 54,72,90,120 w AI 1.00 A. �... 1_ -.1 1.50 O 0,875 Power connection J on opposite side Ill 2.00 -- 1. 5 0.675 Power _I connection 1--1.25 Control panel door -�S{.Ot7 D L P T 6.53 0j+- 0.56 Duct opening L _ C === IiIl Dint opening 00 .3 0.875 Powor u-i.- connection on opposite Side f- ji L2 1.00 lll-AN 3. Right hand heater shown. 1 00 Left hand heater is mirror _ Mounting flange bottom image of right hand. unit sizes 54,72,90,120 Table 7. Electric heat dimensions(in.)and weights fa+? 1= l4.r. 17.93. 6,13 -.7!3 13 50 ..35 0.03 10.0 18 14416 14.33 10.13. 3.79 1050, 8.15 4,03, Mt 24 18,06 17.73 7.63 6.29 13.50 933 0.30 11,3 36 13,06 23.06 13.60 12423 13.50 9.13 0.80. 12.8 54 18,06 27.25 13 63.. . .... 11.57 13 50 ..2.63 0„22 16.0 72 16.06 S_F..S 15.63: 11,67 13.50 11.63 4.3d. 17.4 30 13,03 27.25 13.63 11,97 13.50 12.33 1.16 1- - • Electric heater is factory mounted on unit discharge • Optional mercury contactors cannot be used with tacearid wired to unit control box. vertical up airflow. • Heater may be mounted with horizontal or vertical up Electric heat may need held-supplied externally- rlirftova. wrapped insulation if the unit is installed in an unconditioned space or it sweating is an issue. Equipment Submittal Page 13 of 17 • SGH 3757-Washington Square February 17,2021 Field Wiring -BCXD Blower Coil -Direct Drive Item: Al Qty: 1 Tag(s): AHU-1 FtELL, ,.i a «,E.�E,�0 E; ,E:1 E„� 1wi�.,E.. ,. a10-- B82QxO - a0v,E.2 L,s,o,E, C „Xi,' '>-I .xuoa owl oN,E+a EMI ,es<ef -fw 1 .on�iesElaw — ' ae+cao.. 14 m>ac=f>cmt —. a aa9coa MI.,' 98ECTl IIII IIIIIIIIIIIIIIIIR 1Si_eNT.i q I MVC 21 TI.MESTW7 N A, L eTo:oz >,—muE=r,,7.3 r" i 1....Mil''''m4sra — IIII T...,aoael's0. EMI ME vaua2 > — ;,P F.1NE]a 4Er2 111111111 • r�::.Rff xE.c nan,w .— —xsrxv.ou Elan MEI Q MSEar 9Es.,zua££ar '. w rn 42 Wt3>LOCX .eg >„ NHL_r H HL Q 9, 9. - 3E .l e sr0 + ssc sa>. sr. ]..wc.aa m, ,wmun E OM R1-� SiO.13: t�M SlG nu f i ! ] 10F. ma. .iN Op ro• Y4. .'*“ SYB U9 Fl PAC .S = � iM1G8R3EF>Tcl*4E44 CI 312f,N SAry& r W :33 IXnk-ranv vE N,-4 SRFb Y1-1 V Ctl4115 R OfENRT .U 3RS] 46.4 yl,f_Kt.3_ E., „�mE 2.b< ]1,3 s.5a cam°_ a, .0 _ 12418.EI 2OVR4N = — A. Z�tiM Q , , ua1 .nd.V> .111i :hl£ .. 0727j5{ 22_.CF—.i. A7> l— CO 4] a PN:[N1 CL@17304c x LJ,e<<"'"" b J lT 9]EC . tCA.. vN ,A, Lif.#vf SIS 4 x W.S 1 a, �J+ iKN 1S3 +cam 7 "3•° IY _ : R2'''.6 ...__.•315'.1 L SS AY.m .Y5... 1YN9 ITI.,. CXID(N'Hm.NA-13 fss.Evs ne-n 2.31-.5 e ze.. wrwmfx-ew.nn< w.-_- x+n< nez EL.� •J,E,4 .Y.A .: J • 315W ...S.A./5 2:cg O2.Y 30.-% a,M .. • .313.7 _ :`Fll 2721• 2PJ1 6?0lf-, SiRL .2., s.s1 ESIA �O 3.. 132 ].W.::3 . 1 2 Erpw w 1 i1318 N.,. a $ - a CLOSE., PYI LM ]29 Lbi pxu v.soa C o as llf9 ]l59 *4. s . 0 x•31I.OP 1C\ .. ..� . . ,, xnau ..._r awvuwa ... --,,,,®.em Equipment Submittal Page 14 of 17 SGH 3757-Washington Square February 17,2021 Field Wiring -BCXD Blower Coil -Direct Drive Item: Al Qty: 1 Tag(s): AHU-1 NOTES. :n,..„,v .,~HAN 'S0 0110 L UNLESS OTHERWISE NOTED,ALL S WATCHES ARE SHOWN AT «ma 1T354 47=P m. (TT FI,AI ATAIDSPHHiiC PRESSURE %.AT SO REA CIoulS. 12 z TAANDITY WITH ALL UTILITIES TURNED OFF.AND AFTER TER A NORMAL SHUTDOWN HAS OCCURRED. ttoHly ib • ' . 2 DASHED LNES 1NOCATERECOUMENONSFILOWIRING BY 1Bm' OTHERS.DASHED SLED ENCLOSURES ANDAR DASHED DEVICE N¢rv^_r OmNramrreaesmal x,-xTxam.Es OUTLINES INDICATE COMPONENTS PROM DED BYTHE FIELD. —"- CI PHANTOM LINE ENCLOSURES INDIC ATE ALTERNATE CIRCUITRY 00£31HEAT Eaa103£ATJ1611 LW MAILABLE SALES OPTIONS SOLID LWESINDICATE WIRING BY aj SnTSP EE EIW,CnLRE TFARE 01330 3. ALL FELD WRING MOST BE IN ACCORDANCE WITH THE NATIONAL - F;1.04013E_Een5 311/0330n4EE:e:E0131s1 I.'NETREPoNIO WNOXLVR ELECTRIC CODE(NEC)STATE ANJD LOCAL REQUIREMENTS.ALL MELD WRING MUST HOVE INSUTALGN VOLTAGE RATING THAT Fbrrow EQUALS OR EXCEEDS UMT RATED VOLTAGE. 1sam FI,11-1030 .a° < Q Nat Q Q 4,0*2 nd F AO .. ]iA a EL:a,IHIC HEAT SCHEMATIC IS LOCATED IN THE ELECTRIC-FEAT ARp ,01102So.¢AacT3<!e+* SAT was .syT ,vV �I.z CONTROL BOX PANEL .C, a del 2..,Cam— ©al ELM FITS T634E1%x1675 WRING SHOWN IS FOR TWO STAGE ELECTRIC HEAT.gE Q Tea c'''S A EAT �a 'I"' n1 INSET"=FOR SINGLE SAGE EH lwlzxra resn BHTS1c .cv.E•2wm3300.0 m2I LVE CI USE CLASS WRING. ylgElg 2030TW.031)30a Q FIELD CONNECTIONS SHOWN ON TEE SAND TB3.7 ARE FOR '°" y^�G< C COOLING MODULATING 520,91S.SEE INSET A'FOR FIELD r& rA1 Q CONNECTIONS TO COOLING TWO POSITION V.4.VES �n�w.v Q "'O ' vw'6, f,0 u+� 1 /; rxm,Lnnl�a.wa Q aeu:ae zAe13 V y, am= �.v ®FIELD CONNECTIONS SHOWN ON TE3-1 ONTO THt11 ARE FOR v HEATING MODULATING VALVES.SEE INSET"C" :SIN'vrm< xm vra 0 sxe FOR FIELD CONNECTIONS TO HEATING TWO POSITION VALVES. rewOa'<cix Teslf�be2WFn SINGLE STAGE ELECHUL HEAT:TWO STAGE ELECTRIC HEAT. Q Sae 0,031+0 Ta.u<alNavlx -.. :Na erx A4N9 a WIRING SHOWN IS FOR MODULATING VALVES. FAwsurs SSE SELECT FOR SANDCOOLING INSET 'N'POSITION �1 2 POSTIOEV VALVE SELE kTIONS FOR HEATING 2ELD 9..OPLIEDA ACTUATOR RARING "`�To w'$m1}cpY�RG4 '" 722 FIELD CONNECTION DHCTS ATORCARING UTILIZES THE 545E CONNECTIONPOINTSAE FACTORY ACTUATOR WRING. nmisl w - laa 116 11 5WI AND TURNED SHOWN IN THE VEEOFT S ARE'TOON.55V CLOSEDNVA +'_wflv'E OR TLREI MODULATING ON(OVEN VALVES E NORA.LL. OPEN(CVII caO ns ARE 3PJEDON WHEN VAL`lESARE NbR.fALIY OPEN VCVT1 OR ++sl CY2=3.D,H1. w+crnN rvns .C1 SYJ IS SHOWN ill THE OFF POSITION.5A715 TURNED ON WHEN _.-. CHANGEOVER CONS APE SELECTED NB,'" 10:0L4VI000A01e0 ICOLT OR COL22=J5.FCTJ. . an-1a 030-1 15 51301 ISALWASY 8I THE OFF POSITION. SP.S5 10,,10 33 wax Q 14 WIRING SHON-.S FOR FACT CRY INSTALLED MOO ALAI LNG 3 aw_v.[S :Re4 ow OEWeERRer+x LOCnTcneOOE 'DAygA LOCATIOM SEE IN R.SEE IMSET'G'FOR CONDENSATE OVERFLOW JUMPER 1 MAN COnTRMFAYE: SEF INSETII"FOR OOSE 05IOPJ DAMPETtANO MODULATING FIELD a.s1_sEL.cF MCAT 1r1� 2 SLATR-'='TAN AND COIL SECTwM SUPPLIED/SHIP LOOSE DRAWER DARING. 2?50121¢rslia 1 ___Co� FSIERHA:FRSI4 AG REMOVE TEST AMA MI PRIOR TO CONNECTING arc_ a ELE:IRm HExcOMmaecx MINING BO%i0 MAIN lIlIT & �'G 613,0 NrwUEO PFV.CE S 18 FIELD CONNECTIONSTiED SHOWN ONT'3-12 AND IB3-13 ARE FOR - LEOE ND MODULATING DAMPER SEE INSET IF FOR!POSITION CAMPER AE+— AND CONDENSATE OVERFLOW FIELD IMMO. DEW" DESCRIPTION "E - LE 9G133TI011 10003E0 1)1 A£10-1£13 EO,?O SARI 1 WIRE IS DMMIT TED WHEN 2-10V HEATING VALVE IS 1N1 ENGIIIE ILNR6 6311E USED n'I £LlT.SG%Wi SWITCH 70105 V6 CPMACTdt;ELM SIG.1 II??I t8 SEE INSET-IX FOR FAN STATUS WIRING SS I.'1,133E 3E311 106,17 (CTRL 3 N) 007 r]lRA[i-P;SLM 5T92 109 1I.2 COMTAtTSR;ELM "R TT ,C 24VOJTPUT IS RATED ISVA ICE COHTACTOR;£LIIT 109 16 I33.1IYI FAN STKus 5,1 COJLRA C VA i SHLOh 110140 84115 <22 FIELD SUPPLIEACTUATOR WIRING UTILIZES THE SAME 412 IIE.131310 EnISA,WSOTST CANT CONNECTION POITTSAS FACTORY ACTUATOR WIIMNG. 1L1 COCIIN00.C 0IL11913310 NOTES 11E¢1 21 VALVES SHOWN IN NORMALLY CLOSED POSED I ON.FOR 1:2 11E313310 000.144E MOTOR 0.1-a NORMALLY OPEN POSITION.THE VALVE SIGNAL BECOMES 251 COHAE OWE OW Rnaw S131311 I 122 CLOSE. 2S2 FPIE2ESTAT ISO R3 MIMMOBP%.'uHPEP ACT40t F 125 ®DAMPER SHOWN It NORMALLY CLOSED PRGTION<-FOR 114 GU1252 AR 503711E0 ACTJOICR 125,12E NORMALLY OPEN POSITION.THE 0AM PER SGNAL BECOMES AO 11001033o4OAMFE 119,311I000 N 131 CLOSE. 451-1 EXEtadGwx£x*ENF SENSOR 104 _ _.. .__.. _........ .... ..__ __.. gym Equipment Submittal Page 15 of 17 SGH 3757-Washington Square February 17,2021 Field Wiring - BCXD Blower Coil - Direct Drive Item: Al Qty: 1 Tag(s): AHU-1 SEE NAMEPLATE FOR VOLTAGE THREE PHASE(0.5,1 HP) INSETS A,WARNING Al L2 L3 - lif2Al2.33U3 VOLTAGE SELECTIONS. UNIT 60,NERO 413=E F.NIL / TELLS I. HEM,:POWER L zas.MO,413: AJ'.6t5 RXUR•N 0001234 AND 0�3A?E9 201Wo WJ CAeall I 1 ]11I Th011 01 O LEI SPEEDCO3AEJ"ME REFER 0414 VAi^31E UKml rn aaflaE➢vH CE C ' 5 E,COE424VES:lME seanc0455555 REWliMOEFCP F .ttJ11RY Li L2 L3 1NSEIC 1QAVERT ISSEMENT (BUS) (BLK) (BETS) I ENRON ORIERRF{t3E a lsvlw4E1 a ELECTRIC HEAT 0�9LESCIC_P1n1RSAna,WE. U U M LTSFIREE.SUP... D CONTROL BOX VWAOd�P.!*.ETC.SEMJJCRE)1LUT -nun.-IITEOYENIp?:'dwrEn as O'1 W 01 LI t3 L3 GNo © nu ESCOAPE+EATEUE1CFstme.,s:�[ 1 2 al,I BEcwRo:s.Caret,C.CrUISTES iJ6t 10 2a 30 w::sonxwo@ mmaae.wrs1 TEST PLUG- > .0 4 1 SERE,=..E:EPAM 121✓53301 ISCE-C C .OIIS.AClI.Cr!ROW FACTORY 1JS2 5ErnLF];1A._ USE ONLY' , 1J54 UTHREE PHASE W/EH NEWS EEs44^.F:RESAESAESDE a.�.REVrEE,R,a.urFm SELECTIONS: sEENrascmuES FarvALIT€ME DIGIT lb I81'GE3.123 Nsva 1al BADVERTENCIA 4WLTfCEPEpIXBC501 r41) Uf%SICIE 600L11 KAO'>EEtmfA 13000C LAB 110500 010YE51,10A5' 46A.,TILUEIC�l£ME4i0R000EO RE♦ ndEmM 1.6£[G CSLS01_Y1£i3O i UESCI.F:CTORB in....CR10743 I v 9 oRyp.gVlm:EM pb0 �P3.1 'P1-2 tP4a Iu fi o- ,. s = ,RP x�CaOstrn ,}1 1 0 Eu�R _, O.1.1�,E L. Ly21. 113-6 1TL•3 =t C,01R 1: c165I91iuCiONO YRh_a aI -VW a ELN1AEC1)AP LOJOI£RASMEY Ir 1J1' �I /77 ann.L03810110401.aASOT._ES A:FRTI RfP4t OiBi NSIEEIC6 IEPYSM6i£s 1J1_] iPY3 NOTICE 'T1 -: LSEC)P?ER CONDUCTORS O NOTICE ..9ll2J63LPE 1J3 JBIrt4.1,5ve M01.44.3 ww1Ef o;4ER mEs 1EEOmv.:T2@S 2� SAWRE T00ot1a aluzia.2 LINE 102 Ew-uacwm aEsslm E'YIFR£Nl G#qK. 1P1-2 USE ISO.MT-2 SO mu ° -utu224-111NE191 rN�/ 4STii.4E3GUE 6£S CONN.CV'LV ISC ra1E' LPL{ LINE 39312-511.12 iw.Fmf OELV... 0E3wrt4910:oy'U@ IAA PC ER6'.P1150 iAE9NFE9:0£0i.Yi000l0UR4 EN-RAMw>ES C VA.w.^£S 1LES:Eia.16, ,UTCICE 1410.0G-ATE CGNC11AVI SOJ89E? NOTES NM@➢E u0w0.P1.1 s MnhFG@M1A TRT?N CECENOUCAJF@. 1.UNLESS OTHERWISE NOTED,ALL SWITCHES ARE SHOWN xo9@wx us�mxaa@rA1fREAfS FAME AT 25°C(77°F).AT ATMOSPHERIC PRESSURE.AT MI % Rr,,Swe Wigs al afuva. RELATIVE HUMIDITY,NBTH ALL UTILITIES TURNED OFF, AND AFTER ANORMAL SHUTDOWN HAS OCCURRED. rsM1m revl LNe 2. DASHED LINES INDICATE RECOMMENDED GELD WRING BY 7701:31E107.1 °RORisr`w nusEn OTHERS.DASHED LINE ENCLOSURESAND/OR DASHED srtuE DEVICE OUTLINES INDICATE COMPONEN IS PROVIDED BY :Ea mm0mc:r ncx THERELD.PHANTOM UNED ENCLOSJRESINCICATE ..1477.77,a5c5775Ea75E:10N z ALTERNATE CIRCUITRY ORAVAI LADLE Gill ER OPTIONS. zt1 s1w:61PM +. SOLID ONES INDICATE WIRING BY THANE OCT 1NREE,,:106E Oa 1.xe; 3 ALL RELDWIRING MUST BE IN ACCORDANCE WTH 76E. 520120@'.PEIOIBILS1CR .0 THE NATIONAL ELECTRIC CODE(NEC),STATE AND ILI 1.154I.l51CONECTSi1TGH w tRnM,0,16 As LOCAL REQUIREMENTS. :e7 R r.Ln�r �J ELECTRIC HEAT SCHEMATIC IS LOCATED IN THE ELECTRIC HEAT CONTROL BOX PANEL. WIRING SHOWN IS FOR NO ELECTRIC HEAT. FOR oe+:cemazA 7AILLICILc9E ELECTRIC HEAT 9NOLE PHASE SEE INSET MEI FOR 0,-01.tt ELECTRIC HEAT THREE PHASE SEE INSET MC Ez»xEanazo x9£ ©CW JUMPER IS PRESENT PROM PIN PI)TO Ell ON UNITS •NTH CWMOTOR ROTATION AS VIEWED FROM SHAFT I =aaIPL-rin'IE END 2rc17„Aw4ATwJLa 0 r 0100m-4,il0 0r55f U MOTOR VOLTAGE CONFIGURATION P2-PS JUMPERED FOR 115V OPERATION ONLY B USE COPPER CONDUCTORS ONLY 77, Equipment Submittal Page 16 of 17 7 et Lt L} L3 fl. (xa cr N vA"kwffiF' v `I,,;Wd:MTI CONTROL WIRING A� IE, d I24- I II II r 7 II N co 5 ESECTMvut=! 1 n I. ICI CONTROL 1 2 f CONrR]L EON I — tIDBWPLIGO DJ "' 7 ITN EWOrtA Q , cn • ca a M m CII _ � Hrx POWER WIRING ADAPTER BOARD MED _ m �Mw > 3 m▪ Cl CBr4i �,3). PE7FIAT O PR9TAi t®E aI era ma I MS ® nll+tC1R E i f cl-r1Si Al. J 1r 22222 O II I Mil ONE ...p. fpxI dYMLW 19*OM —I-® �`HD DV — CD 1 CI i M 3 v CD rn 42 a' I 3 ', e a ei C Fff ®WARNING 11P2MOUw raga AVERTISSEMENT MINIMUM CIRCUITAMPACITY;2312A ewloXoxwEmo9e '. NOTICE .41MITM41.4,411,A,MM. MAXIMUM FUSE SIZE'.25.00A MSIE COPPER GO OUCIORE ODLM saassossasswwwws MEPI .W 198a.a 42 2 222 oeeDSXNU YUNOOIYI 3 NOTES MmEN RPPo Elf 4ax0 CICAx HNIZSP OE ffD.VICE NU11724.SWITNTN5 ME Y IRI:If100 I.MS....SS R1.9t1 IS tabIROEFOMMMTWIRM.I. t' am 4sd ar TED r Al Aiw19P 1rfH. F WNW.N ra.w.a. i PPESSLIPE,A160I22.RELATER HIS ONYWI1i AVIS WM PiE WE UIEE A N4PoAK6HUIDONN1W OCCURAW. ss wswassws I.OASIEnI. Fs nCWFRf.MMf OITffln 1UI09fR OL£'CN O DOCTES Ca NE.. EI . .. T WRIOB mass owNEo LIIEEIA.L EI= wuP Na F�a AUTTID n�MS con6uea ®gbVERTENCIA Ip AIEION Pl f HENCE RIM HES HI'RI F6 C A: E'UHG'Ooc UT M A I9 0 COMPONENTS PRON&'D TITHE EELD. FARE CEIADIa F US M Il m TOLLS I.INPS IXbCATE WAMO BYIRUVECO EXIXAIxRR EF oMW Y^a`l'En[1.0(F�HFxI HI ETAV IQ 9.ALL RELOIMRIHG MUST BEIN OCCOR0410E ('BV I W 211222E22TIOHAL ELECTRIC GONSOENC), .A P.Tac410 111 IEMIIIRMOX18.µ11KIR I USECLUON I WEND PORLOWOOITAAD MPLICATWILS. :LRhKEIALSIDONTE CONDl1Ci6�SDE 4'VBREI N MUM MUST NAEEA11 INGUTATIONl9LT4OERATHG NEhRLWKEfi BAO NO E9LM 0162222.22 Q lhAI E0U4 S L L:CEF08 Lila MrEOWIrAE PM AK PPMR 47I001EU20E COX1MCWPET: M INC B50U1P 481H01RUCGId1EeAXTEPIOR®PUEOE Q ES. PR4'.00M MVOEEF EIECUiQ o NNe.MPIMIMutp. N N , Air System Sizing Summary for Tenant SpacRECEIVED Project Name:2020-0971 SGH-Washington Square n01/29/2021 Prepared by:THORSON,BAKER,&ASSOCIATES Nlki v v In' 01:09PM CITY OF TIGARD Air System Information BUILDING DIVISION Air System Name Tenant Space Number of zones Equipment Class CW AHU Floor Area 993.0 ft' Air System Type SZCAV Location Portland,Oregon Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 2.9 Tons Load occurs at Jun 1400 Total coil load 35.1 MBH OA DB/WB 88.4166.8 °F Sensible coil load 26.4 MBH Entering DB I WB 81.3/66.8 °F Coil CFM at Jun 1400 974 CFM Leaving DB/WB 56.1 154.8 °F Max block CFM 974 CFM Coil ADP 53.3 °F Sum of peak zone CFM 974 CFM Bypass Factor 0.100 Sensible heat ratio 0.754 Resulting RH 52 % CFM/Ton 332.9 Design supply temp. 55.0 °F ft'/Ton 339.6 Zone T-stat Check 0 of 1 OK BTU/(hr•ft2) 35.3 Max zone temperature deviation 0.0 °F Water flow Q 14.0°F rise 5.02 gpm Central Heating Coil Sizing Data Max coil load 11.7 MBH Load occurs at Des Htg Coil CFM at Des Htg 974 CFM BTU/(hr•ftz) 11.8 Max coil CFM 974 CFM Ent.DB/Lvg DB 59.9/71.1 °F Water flow Q 20.0°F drop N/A Humidifier Sizing Data Max steam flow at Des Htg 6.34 lb/hr Air mass flow 4374.85 Ib/hr Airflow Rate 974 CFM Moisture gain 00145 Ib/Ib Supply Fan Sizing Data Actual max CFM 974 CFM Fan motor BHP 0.27 BHP Standard CFM 972 CFM Fan motor kW 0.21 kW Actual max CFM/ft' 0.98 CFM/ft' Fan static 1.00 in wg Outdoor Ventilation Air Data Design airflow CFM 195 CFM CFM/person 14.94 CFM/person CFM/ft' 0.20 CFM/ft' Hourly Analysis Program 5.11 Page 1 of 4 Zone Sizing Summary for Tenant Space Project Name:2020-0971 SGH-Washington Square 01/29/2021 Prepared by:THORSON,BAKER,&ASSOCIATES 01:09PM Air System Information Air System Name Tenant Space Number of zones 1 Equipment Class CW AHU Floor Area 993.0 ft' Air System Type SZCAV Location Portland,Oregon Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Zone Terminal Sizing Data Reheat Zone Zone Design Minimum Reheat Coil Htg Unit Htg Unit Mixing Supply Supply Coil Water Coll Water Box Fan Airflow Airflow Zone Load gpm Load gpm Airflow Zone Name (CFM) (CFM) CFM/ft' (MBH) @ 20.0°F (MBH) @ 20.0°F (CFM) Zone 1 974 974 0.98 0.0 0.00 0.0 0.00 0 Zone Peak Sensible Loads Zone Zone Zone Cooling Time of Heating Floor Sensible Peak Sensible Load Area Zone Name (MBH) Cooling Load (MBH) (ff) Zone 1 24.1 Jun 1400 2.6 993.0 Space Loads and Airflows Time of Cooling Peak Air Heating Floor Zone Name/ Sensible Sensible Flow Load Area Space Space Name Mult. (MBH) Load (CFM) (MBH) (ft=) CFM/ff Zone 1 BOH 1 2.6 Jun 1400 104 0.3 105.0 0.99 Retail Sales Area 1 21.0 Jun 1400 848 2.2 830.0 1.02 Toilet Room 1 0.5 Jun 1400 21 0.1 58.0 0.36 Hourly Analysis Program 5.11 Page 2 of 4 Ventilation Sizing Summary for Tenant Space 20-0971 SGH-Washington Square )RSON,BAKER,&ASSOCIATES g Method Sum of Space OA Airflows on Airflow Rate 195 CFM 3tion Analysis Floor Maximum Required Required Required Required Uncorrected Area Maximum Supply Air Outdoor Air Outdoor Air Outdoor Air Outdoor Air Outdoor Air ,ce Name Mult. (ft') Occupants (CFM) (CFM/person) (CFM/ft') (CFM) (%of supply) (CFM) 1 105.0 2.0 104.3 0.00 0.12 0.0 0.0 12.6 ;a 1 830.0 11.1 848.4 7.50 0.12 0.0 0.0 182.6 1 58.0 0.0 20.9 0.00 0.00 0.0 0.0 0.0 :e Multipliers) 973.6 195.2 ogram 5.11 Air System Design Load Summary for Tenant Space Project Name:2020-0971 SGH-Washington Square 01/29/2021 Prepared by:THORSON,BAKER,&ASSOCIATES 01:09PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 HEATING DATA AT DES HTG COOLING OA DB/WB 90.0°F/67.0°F HEATING OA DB I WB 22.0°F/18.4°F Sensible Latent Sensible Latent ZONE LOADS Details (BTU/hr) (BTUlhr) Details (BTUIhr) (BTU/hr) Window&Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 1007 ft2 1917 - 1007 ft2 1537 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 987 ft2 0 - 987 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 0 W 0 - 0 0 - Task Lighting 2291 W 7815 - 0 0 - Electric Equipment 200 W 682 - 0 0 - People 13 3659 3528 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 70%/70% 9851 2470 70% 1076 0 »Total Zone Loads - 23924 5998 - 2613 0 Zone Conditioning - 23599 5998 - 2427 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 974 CFM 0 - 974 CFM 0 - Ventilation Load 195 CFM 2205 -2165 195 CFM 9990 6688 Supply Fan Load 974 CFM 722 - 974 CFM -722 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain/Loss 0% 0 - 0% 0 - Total System Loads 26526 3833 11696 6688 Central Cooling Coil - 26526 8436 - 0 0 Central Heating Coil - 0 - - 11696 - Humidification Load - - -4604 - - 6688 »Total Conditioning - 26526 3833 - 11696 6688 Key: Positive values are clg loads Positive values are htg loads Negative values are htg loads Negative values are clg loads Hourly Analysis Program 5.11 Page 4 of 4