Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY OF TIGARD MECHANICAL PERMIT a COMMUNITY DEVELOPMENT MECHANICAL MEC2021-00501 Date Issued: 7/20/2021 T t C-A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 2S111ACO2901 Jurisdiction: Tigard Site address: 9550 SW MURDOCK ST Project: Templeton Elementary School Subdivision: None Lot: None Project Description: (2)new RTU's for renovation of existing school. Contractor: AMERICAN HEATING INC Owner: TIGARD-TUALATIN SCHOOL 5035 SE 24TH AVE DISTRICT 23J PORTLAND, OR 97202-4765 6960 SW SANDBURG ST TIGARD,OR 97223 PHONE: 503-239-4600 PHONE: FAX: 503-239-7038 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 07/15/2021 $3,998.63 Class of Work: ALT Type of Const: VB Plan Review 07/15/2021 $999.66 Occupancy Grp: E Occupancy Load: 12%State Surcharge-Mechanical 07/15/2021 $479.84 Stories: Info Process/Archiving-Lg$2.00(over 07/15/2021 $16.00 Project Valuation: $147,530.00 11x17) Info Process/Archiving-Sm$0.50(up to 07/15/2021 $27.50 11x17) Fuel Air Handlers Fuel Types: Natural Gas Units<10000 cfm: Gas Pressure: Units>10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>= 100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 2 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: 4 Vent Systems: Total $5,521.63 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules Issued By: - o Va.W De,We Permittee Signature: O liAppjct,Olet w, Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. � CE1VE® Q 1 Mechanical Permit Applica FOR OFFICE USE ONLY Cityof Tigard Received g Date/By: / / ��+ Permit No.: /►�.. / �'`,�_ 111 13125 SW Hall Blvd.,Tigard,OR 97223 MAY 1 7 Z021 r� (jJ,v • = Phone: 503.718.2439 Fax: 503.598.1960 Plan Rcv em / J, 2 Date/By: / /3 ' Other Permit. ����_ter,.,x�y� 'I'I G n It D Inspection Line: 503.639.4175 CITY OF TIGARD Date Ready/By: furls- See age 2 for 011/ r" Internet: www.tigard-or.gov BUILDING DIVISION Notified/Method: ;+T, Supplemental Information '' ,---.1 1511. _ _ •.Yix ' "..ii.°"""�"' n�-, '.`1j '- - - Mechanical permit fees*are based on the value of the work ❑New construction ®Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. Value:$147 530.00 ' CATFCORY OF CONSTRU = �^�^�vxrA. tlea a� ,, -: ilifd O 1-and 2-family dwelling ®Commercial/industrial ❑Accessory building For special information use checklist O Multi-family ❑Master builder 0 Other: Description Qty. I Ea. Total !+ - , Heafing/cooling: JOB SITE INFORMATION AND LOCATION ,, Air conditioning 46.75 Job site address: 9550 SW Murdock St Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: Tigard,OR 97224 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name: Templeton Pre-K+(HVAC) Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 ;. . f, r2° 74 1 3 ,. '' Gas fireplace/insert 33.39 \ _ " - ' Flue vent for water heater or gas (1l Remodel of existing school to include (2) new rooftop units fireplace 23.32 `� on existing curbs using curb adapters,provide and install new electric duct heaters,ceiling Loglighter(gas) 23.32 Wood/pellet stove 33.39 in in exhaust,roof-mounted and dryer booster tans with associated ductwork and grilles. Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 k, 2 _ Other. 23.32 © TENANT Environmental exhaust and ventilation: Ilk Name: Range hood/other kitchen �� equipment 33.39 Address: Clothes dryer exhaust 33.39 City/State/ZIP: Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 - ., ® CONTACT PERSON Other: 23.32 Business name: American Heating, Inc. Fuel piping: $14.15 for first four;$4.03 for each additional Contact name: Melina Vaca Furnace,etc. Gas heat pump Address: 5035 SE 24th Ave. Wall/suspended/unit heater City/State/ZIP: Portland,OR 97202 Water heater Phone: 503-519-1337 Fax:: Fireplace Range E-mail: m.vaca@americanheating.net Barbecue CONTRAC4t fi ,t ^ Clothes dryer(gas)E � r Ilin I Business name: American Heating, Inc. Other .t fi4::fTei .. PEB,. a Address: 5035 SE 24th Ave. Subtotal 147930 City/State/ZIP: Portland,OR 97202 Minimum permit fee($90.00) 00.00 Plan review(25%of permit fee) 733.e3 Phone: 503-519-1337 Fax: State surcharge(12%of permit fee) 393.44 CCB lic.: 33135 TOTAL PERMIT FEE 4349.12 This permit application expires if a permit Is not obtained within 180 .,�y are�m er adu.�.n days after it has been accepted as complete. Melina Vaca 021 ern.em®emam nee a. <s.aarevew Authorized signature: -�:zax1 05.12 1ssnl,a*ca Fee methodology set by Tri-County Building Industry Service Board Print name: Melina Vaca Date: 05/12/2021 5.02-/ • b l:\Building\Permits\MEC_PermiiApp_040113.doc 440-4617r(11/02ICOM/WEB) City of Tigard ■ COMMUNITY DEVELOPMENT DEPARTMENT C TIGARD Building Permit Review — Commercial - With Land Use Building Permit #: /n aa-1_0(15-0 J Site Address: 9550 SW Murdock St Suite/Bldg#: Project Name: Templeton/Twality Porch Building Mechanical (Name of commercial business occupying the space. If vacant,enter Spec Space.) Plai ir--Review Proposal: Mechanical Permit - remodel of existing school to include (2) new rooftop units on existing curbs using curb adapters, provide and install new electric duct heaters, ceiling exhaust, roof-mounted and dryer booster fans with associated ductwork and grilles. ® Verify site address/suite# exists and active in permit system. 0 River Terrace Neighborhood: ® Yes ❑ No ® Land Use Case#: MMD2020-00029 a Plans Match Approved Land Use: ® Site Plan a Landscape Plan 0 Other: 0 Urban Forestry Plan ® Elevation Plan IY Building Height: Maximum Height N/A Actual Height ® Conditions Met: 0 Prior to Submittal IX Prior to Permit Issuance ®/Ausiness License: Exists: ❑ Yes ❑ No,applicant was provided a business license application ® Public Facilities Improvement (PFI) Permit Required: 0 Yes,applicant was notified ❑ No Applied For: N Yes ❑ No, stop intake Notes: Approved by Planning: MB Date: 7/6/2021 Revisions (after Building Submittal only) Reviewer Date Revision 1: 0 Approved 0 Not Approved Revision 2: ❑ Approved 0 Not Approved Revision 3: ❑ Approved ❑ Not Approved Buildiug Permit Submittal Original Submittal Date: s— /7 jl1 Site Plans: # it/I/ Building Plans: Building Permit#: Ir�'' n B ter building permit# above. Workflow Routing: an -dng ❑ Engineering ❑ Permit Coordinator 2:1--1411rXng Workflow Sign-off: 1gn- for Planning(include notes from planning review) Route Application Documents: utlding: original permit application,site plans,building plans, engineer and beam calculations and trust details,if applicable,etc. Notes: By Permit Technician: Date: -7/4// I:\Building\Forms\BldgPermitRvw_COM_W ithLandUse_111819.docx FtRitleerizk Review ❑ Slope at building pad: ❑ PFI Permit#: ❑ Conditions "Met"prior to issuance of building permit ❑ Easements (encroachments) per engineering conditions of approval and p .t (not typical on SDR/CUP) ❑ Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes ❑ No Assess Water Quantity Fee in-lieu‘ ❑ Yes ❑ No LIDA Facility on lot: ❑ Yes ❑ No ❑ NOT Approved by Engineering: Date Notes: Approved by Engineering: Date: Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved 0 Not Appro\ d Revision 2: ❑ Approved ❑ Not Approve: Revision 3: ❑ Approved ❑ Not Appro -d Perriit Coordinator Review ❑ Conditions "Met"prior to issuance of buil. ,g permit ❑ Approved,NOT Released: Date: Notes: ss Revisions (after Building Submittal only Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: ❑ SDC Fees Entered: Wash Co Trans Dev Tax: ❑ Yes ❑ N/A Tigard Trans SDC: ❑ Yes ❑ N/A Parks SDC: ❑ Yes ❑ N/A ❑ OK to Issue Permit Approved by Permit Coordinator: Date: I:1Building\Forms\Bl dgPermitRvw_COM_WithLandUse_111819.docx Mechanical Permit Applica ECE VE® FOR OFFICE USE ONLY 'U City Of Tigard Date/Byed : '1 p, 'I fI 9 7 ! rW/7 Permit No.: �Z^i ],t_tJ ) 1 h • 13125 SW Hall Blvd.,Tigard,OR 97223 MAY 1 7 2021 Plan Review w _ wC.�(/.,r.r Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Other Permit: etJD�2'011/,'�y° T'I G A R D Inspection Line: 503.639.4175 Date Ready/By: line See age 2 for V Internet: www.tigard-or.gov CITY OF TIGARDMe o Notified/Method Supplemental Information BUILDING DIVISION TYPE OF WOW,- COMMERCIAL FE15-a.,Sf'IWDULE.. USE C L'ut1'- j Mechanical permit fees`are based on the value of the work ❑New construction ®Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit Value:$147,530.00 CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* ❑ 1-and 2-family dwelling ®Commercial/industrial ❑Accessory building For special information use checklist ❑Multi-family ❑Master builder ❑Other: Description Qty. I Ea. I Total JOB SITE INFOR39ATION AND LOCATION HeatinpJcoolio>;: ' ° - Air conditioning 46.75 Job site address: 9550 SW Murdock St Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: Tigard,OR 97224 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name: Templeton Pre-K+(HVAC) Duct work23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Other. 23.32 Subdivision: Lot no.: e Other fuel appliances: Tax map/parcel no.: Water heater 23.32 �1 DESCRIPTION OF WORK Gas fireplace/insert 33.39 Flue vent for water heater or gas `� c1� Remodel of existing school to include (2) new rooftop units fireplace 23.32 on existing curbs using curb adapters,provide and install new electric duct heaters,ceiling Log lighter(gas) 23.32 Wood/pellet stove 33.39 I exhaust,roof-mounted and dryer booster fans with associated ductwork and grilles. Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 \� Other. 23.32 O`'n. ❑ PROPERTY OWNER 0 TENANT ' "' Environmental exhaust and ventilation: Name: Range hood/other kitchen equipment 33.39 Address: Clothes dryer exhaust 33.39 City/State/ZIP: Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 '® APPLICANT ® CONTACT PERSON Other 23.32 Fuel piping: Business name: American Heating, Inc. $14.15 for first four;$4.03 for each additional Contact name: Melina Vaca Furnace,etc. Address: 5035 SE 24th Ave. Gas heat pump Wall/suspended/unit heater City/State/ZIP: Portland,OR 97202 Water heater Phone: 503-519-1337 Fax:: Fireplace Range E-mail: m.vaca@americanheating.net Barbecue '+F'''- CONTRACTOR Clothes dryer(gas) �Other: Business name: American Heating, Inc. ' .; ,'MECHANICAL PERMIT FEES'"!_� ,t.., � _ Y) Address: 5035 SE 24th Ave. Subtotal 147530 City/State/ZIP: Portland,OR 97202 Minimum permit fee($90.00) m.m Plan review(25%of permit fee) 793.es Phone: 503-519-1337 Fax: State surcharge(12%of permit fee) 363.94 CCB lic.: 33135 TOTAL PERMIT FEE 434912 This permit application expires if a permit is not obtained within 180 04III egnw y„z,i;,,,7444 days after it has been accepted as complete. Authorized signature: Melina Vaca os.u,a® .oroo °°" 'el.`"-11re e` Vc ee-uGJS.&.iz "ism:ztmao • Fee methodology set by Tri-County Building Industry Service Board Print name: Melina Vaca Date: 05/12/2021 I:)Building\Permits\MEC_PermilApp_040113.doe 440-4617T(11/02/COM/WEB) Lina Smith From: Lina Smith Sent: Thursday, May 20, 2021 1:09 PM To: m.vaca@americanheating.net Cc: Monica Bilodeau; #Building Permit Technicians Subject: Templeton Elementary mechanical permit - includes rooftop units Attachments: BldgPermitRvw_COM_WithLandUse_111819.pdf Hi Melina, Can you please e-mail us the plans for this one so the project manager Monica (copied on this e-mail) can review them? She's currently working from home. Monica, after you review the plans can you please fill out this routing sheet and send it back to us? Thank you! Lina Lina Smith Assistant Planner City of Tigard I Community Development 13125 SW Hall Blvd.Tigard, OR 97223 E-mail: LinaCS@tgard-or.gov