TWALITY MIDDLE SCHOOL 14650 SW 97TH TIGARD, OR, 97224 Fire Alarm System Submittal Equipment Submittal July 5, 2019 Johnson Controls 6305 Sw Rosewood St,Suite A Lake Oswego,Or 97035 Project: TWALITY MIDDLE SCHOOL 14650 SW 97TH TIGARD,OR,97224 Customer: PORTLAND ELECTRICALCONST INC 1019 7TH ST OREGON CITY,OR,97045 Date: July 5, 2019 Sales Representative: BRYAN ADAMS Fire Alarm System Submittal Equipment Submittal Please contact the SimplexGrinnell Service Department TWO WEEKS IN ADVANCE to schedule a technician for checkout. Simplex Grinnell District Contact Information: SimplexGrinnell Phone: 503-683-9000 6305 Sw Rosewood St, Suite A Service: 503-683-9001 Lake Oswego, Or 97035 Fax: 503-675-6521 Prepared by: SimplexGrinnell CHRIS NEASE Design Team Project Engineer: MIRANDA CASTLE San Jose, Costa Rica Industry Park Forum 1 Submittal Approval: Approved by: Date: Please return one copy of the approved submittals to the above SimplexGrinnell office. Johnson d v Bill Of Material Controls -' Project Number Project Name 612974701 TWALITY MIDDLE SCHOOL PID DESC RPTI ON Qty. Notes Required FACP-Fire Alarm Control Panel 5820XL-EVS SK FIRE ALARM PANEL W/EMERGENCY VOICE SYSTEM,120VAC 1 EVS-VCM SK VOICE CONTROL MODULE 1 2081-9276 BATTERIES-33AH(2x) 1 LTE4010CF-AT DSC LTE CELLULAR COMMUNICATOR 1 SK-5860 SK REMOTE ANNUNCIATOR 2 EVS-100W SK INTELLIGENT 100W AUDIO AMPLIFIER,120VAC 2 SK-5496 SK INTELLIGENT POWER MODULE 6A 5 AL3000LX ALTRONIX POWER SUPPLY 1 2081-9272 BATTERIES-6.2AH(2x) 8 Initiating/Control Devices SK-PHOTO SILENT KNIGHT SMOKE SENSOR 25 SK-HEAT SILENT KNIGHT FIXED TEMP HEAT DETECTOR 4 B501 SILENT KNIGHT STANDARD SENSOR BASE 29 SK-DUCT SILENT KNIGHT DUCT SMOKE DETECTOR 30 RTS151KEY REMOTE TEST STATION W/KEY SWITCH 30 SK-RELAY SILENT KNIGHT ADDRESSABLE RELAY MODULE 36 SK-MONITOR SILENT KNIGHT SINGLE MONITOR MODULE 6 SK-PULL-SA SILENT KNIGHT PULL STATION SINGLE ACTION 10 STI-1100 STI PULL STATION STOPPER,W/HORN,FLUSH MNT 10 Notification Devices SWL MULTI CD STROBE,WALL MNT,WHITE,FIRE,CLEAR 37 SPSWL MULTI CD SPEAKER/STROBE,WALL MNT,WHITE,FIRE,CLEAR 46 STI-9705-R HORN/STROBE/SPEAKER DAMAGE STOPPER,FLUSH MNT,RED 8 SPSCWL MULTI CD SPEAKER/STROBE,CEILING MNT,WHITE,FIRE,CLEAR 80 SPSWK WP MULTI CD WALL SPEAKER STROBE 1 Miscellaneous/OP Products DH24120FPC DOOR HOLDER,SEMI-FLUSH,CHRM 12 SK-7628 END-OF-LINE RESISTOR 4.7K 21 ELR-47K END-OF-LINE RESISTOR 47K 6 • SILENT IntelliKnight° Model 5820XL-EVS KNIGHT Addressable Fire Alarm Control Panel with Emergency Voice System by Honeywell The IntelliKnight System is the easy way to make the most of fire alarm technolo . IntelliKnight 5820XL-EVS offers an Emergency Voice System integrated with the fire alarm functions of the control panel. The 5820XL-EVS offers built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL-EVS system, or to locate your nearest source, please call 800-328-0103. Description 5820XL-EVS is an intelligent addressable fire alarm control panel combined with an Emergency Voice System (EVS). When the EVS features are enabled, they are integrated with the fire alarm and voice evacuation functions of the control panel. The 5820XL-EVS panel and accessories provide features to meet the requirements for Mass Notification ', Systems as described in UL 2572. els mawa ow -; The basic 5820XL-EVS system can be expanded by adding On me modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent w t.. power module. 5820XL-EVS supports SD or SK devices. Features • Built in support for 99 SK detectors and 99 SK modules, Model 5820XL-EVS expandable to 396 SK detectors and 396 SK modules using . Programmable date setting for Daylight System Sensor protocol Saving Time • Built-in support for 127 SD devices, expandable to 508 SD • Two built-in Form C programmable relays devices using the SD protocol rated at 2.5 amps at 27.4 VDC • Support of up to four EVS-50W, EVS-100W or EVS-125W • 6 amp power supply and maximum charging amplifiers for a maximum of 500 watts capacity of 35 amp hours (An additional • Each amplifier has four built-in speaker circuits expandable cabinet enclosure is required for batteries in to eight excess of 18 amp hours) • 15 Recordable one minute messages that can be mapped to • Improvements in SKSS software deliver five eight EVS buttons times faster uploads/downloads • Can select EVS message as priority over fire • 16 built-in speaker group switches • Support of up to four EVS-RCU's. The EVS-RCU meets the expandable to 32 requirements for a LOC • Built-in RS-232 and USB interface for • Six FlexputTM I/O circuits programming via PC • Central station reporting by point or by zone Compatibility • Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor, and Wheelock® The 5820XL-EVS is compatible with the • Supports Class B (Style 4) and Class A(Style 6) configu- following EVS components: ration for SLC, SBUS, and Flexput circuits • EVS-50W - 50 watt amplifier • 13 pre-programmed output cadences (including ANSI-3.41) • EVS-125W - 125 watt amplifier and 4 programmable outputs • EVS-100W - 50/100 watt amplifier • Built-in annunciator with 80-character LCD display • EVS-100WBU - External backup amplifier • RS-485 bus provides communication to system accessories • EVS-INT50W- 50 watt internal amplifier • UL listed for Continuous or ANSI 520Hz speaker tones that • EVS-SW24 - 24 switch expander meet NFPA 72 Low Frequency Signal Requirements for • EVS-VCM - Voice control module Sleeping Areas when used with the EVS-INT5OW or EVS- • EVS-RCU - Supervised remote control unit 100W amplifiers and compatible speakers. P/N 351562 Rev G ©2016 Honeywell International Inc. 1 ' \ - t • r V \ • \ /t 1 . 1 , ,r I 1 SKYInSmn SK.Oucl InpoluMoN Snake Detector Xla e ,"'.. l" a r♦ S.t 34 7 n IMerNp N Mackie Morale, peep bodb, iv YodWe Medals Rohl* YaEWe EYSiiCU iolitEVS-125W SEtUB 5820%lEY6 144We SX PWLA AGAaesbk 44444 1.01.0 I t I i i WI&nee SK•Phdp SK Ion 5IOIN1 C06mMe Bpurebr Relayhdtlor ry,cw Oal Sew NoeBps SBUS 4 I ( penYerxunem, so-ssn.aia mmw I4 1 . 44XL �q Ndltiicalian'Aue p ww¢a+wwdu° 4— 0 0— - I ® ea.µ. t Co e acne Santo''' Pau 4-- —. -.{p�. Be+a 5nme'H«r,e area Nt°s g,pµ p;leavrs 3uGens 411111 L,...' `.✓ �� seas CommandCor system __ ____s VCM ar RYM —,.. l VAIIMUL- 111:11 --- .eaa wwae<wwa eroeme triA“Crwr LED Annunooata EVS SSWme rogue ,Saeta Shwas; or lapotWt Physical Meets the requirements for NFPA 72 Local Protective Flush Mount Dimensions: Signaling Systems& Emergency Communication Systems. 20.25"W x 26.75"H x 2.5"—3"D Other Listings: (51.4 W x 68 H x 6.4-7.6 D cm) CSFM; OSHPD (CA)OSP-0065-10 Overall Dimensions: 20"W x 26.5"H x 4.6"D Compatible Devices (50.75 W x 67.3 H x 11.8 D cm) See the specification sheets listed below for a complete Color: Red listing of the SD and SK devices. Environmental 53624 SD Devices Data Sheet Operating Temperature: 32°F— 120°F (0°C—49°C) 53623 SK Devices Data Sheet Humidity: 10%—93% non-condensing Ordering Information Electrical > 5820XL-EVS FACP with Emergency Voice System Primary AC: 120 VAC @ 60 Hz, 2.5A EVS Accessories Total Accessory Load: 6A @ 27.4 VC power-limited EVS-50W 50 Watt Amplifier Standby Current: 275 mA EVS-125W 125 Watt Amplifier Alarm Current:440 mA EVS-100W 50/100 Watt Amplifier Battery Charging Capacity: 7 to 35 AH EVS-100WBU External Backup Amplifier Battery Size: 18 AH max. allowed in control panel cabinet. EVS-INT50W 50 Watt Internal Amplifier Larger capacity batteries can be housed in RBB accessory EVS-CE4 4 Circuit Audio Expander cabinet EVS-SW24 24 Switch Expander Six Conductor Wiring: Two voice bus &four SBUS EVS-VCM Voice Control Module Listings VIP-TR Panel Trim Ring to flush mount NFPA 13, NFPA 15, NFPA16, NFPA 72: Central station; SK-SCK Seismic Compliance Kit remote Signaling; Local Protective Signaling Systems; EVS-RCU Supervised Remote Command Unit Auxiliary Protected Premises Unit; &Water Deluge releasing service. Suitable for automatic, manual,waterflow, sprinkler- supervisory (DACT non-coded)signaling services. - UL 864 and UL 2572 irSILENT This document is not intended to be used for installation purposes.We try to keep our product information up-to- NI KNIGHT date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road,Northford,Cr 06472 Phone:(203)484-7161, Fax: (203)484-7118. For Technical Support, by Honeywell Please call 800-446-6444.www.silentknight.com. tSILENT ip KNIGHT by Honeywell EVS-VCM Voice Control Module Installation Instructions SBUS Address DIPs -SBUS axe* The EVS-VCM Voice Control Module is contained within the Silent Knight EVS Series panel enclosure. It provides a supervised microphone for live Dead Front Panel communication and an interface for the Mounting Holes a:3 Emergency Voice System. d VBUS Note: Installation and wiring of this device must be done in ! AUx accordance with NFPA 72 and local ordinances. P Audio Input ".➢7 Compatibility i Audi o IC Trigger The EVS-VCM is compatible with the Figure 1: Back View of EVS-VCM IntelliKnight 5820XL-EVS. For programming and addressing, refer to Installation manual Specifications for 5820XL-EVS (PN LS10061-001SK-E). Standby Current: 60 mA Board Layout & Mounting Alarm Current: 80 mA 1. Open the cabinet door and the dead Wiring to a FACP front panel. 2. Remove AC power and disconnect the See Figure 2 to properly wire the EVS-VCM backup batteries from the main control to the FACP SBUS. panel. Mount the EVS-VCM in the middle section of the dead front on the six mounting studs. } EVS-VCM � `— See Figure 1. N�r Supervised tr.9 Power !'^Agf" Limited 1111111111110 11441.111 Figure 2: Wiring the EVS-VCM to the FACP Document LS10067-001 SK-E Rev A ECN: 13-0146 EVS-VCM Voice Control Module Installation Instructions Installing the Microphone See Figure 5. To install the microphone: 1. Clip the microphone into the microphone clip. See Figure 3. —► > 1 . % 2. Figure 3: Sliding Microphone into Microphone Figure 5: Installing Strain Relief Clip Clip 4. Push the strain into the hole in the dead 2. Insert microphone cord through hole at front panel. the bottom of the dead front panel. See 5. Restore AC power and reconnect the Figure 4. backup batteries. AIM Figure 4: Microphone Cord Inserted Through Dead Front Panel Hole 3. Attach strain relief clip to microphone cord. The strain relief clip should have about 2%" of microphone cord through it. SILENT Ittk KNIGHT by Honeywell 12 Clintonville Road Northford,CT 06472-1610 USA 203-484-7161 Fax:203.484.7118 www.silentknight.com 2013 Honeywell International Inc. 2 Document LS10067-001 SK-E Rev A Honeywell QSTLENT KNIGHT --5860 Remote Annunciator The 5860 remote annunciator,can be used to operate and program Honeywell Silent Knight fire alarm control panels(FACPs)from anywhere within the system. The 5860 features include an 80-character backlit LCD providing easy-to understand system messages.The annunciator is ergonomically designed with over-sized buttons for the most frequently used features,like Reset '- and Silence. P g' In addition to status messages displayed on the LCD,there are five LEDs for alarm,supervisory,trouble,silence,and AC power status. The 5860 annunciator is available in gray to match virtually any decor and 5860/5860R red for applications where the annunciator must stand out.The annunciator enclosure can be surface or flush mounted.A trim ring kit is available for surface mounting. COMPATIBILITY The 5860 is compatible with the following Honeywell Silent Knight FACPs: 6820:Addressable fire alarm control panel with up to 1,110 addressable points 6820EVS:Addressable fire alarm control panel with an emergency communication systems and up to 1,110 addressable points 6808:Addressable fire alarm control panel with up to 198 addressable points 6700:Addressable fire alarm control panel with up to 100 addressable points 5820XL:Addressable fire alarm control panel 5820XL-EVS:Addressable fire alarm control panel with an emergency communication systems 5808:Addressable fire alarm control panel 5700:Addressable fire alarm control panel r b `-'; ' -. N : ,- i __ice S • 80-character backlit • Support for • Five Status LEDs • Accommodates wiring • Accepts user codes or LCD display(4 lines simultaneous use of Available in red or light lengths up to 6000 ft. fire fighter's key •with 20 characters per multiple 5860s gray color from the control panel • Larger keypad buttons line) • Easily view current for added design and makes it easier to • Tactile/audible status by alarms, install flexibility maneuver for system feedback when a key is supervisories,or reset and silencing pressed on the troubles annunciator • Uses the RS-485 SBUS to interface with the panel 5860 Technical Specifications Fora complete listing of all compliance approvals and certifications,please visit www.silentknight.com. Microsoft.Windows,and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Wire Runs Up to 6000 Feet From FACP Silent Knight`and .. Honeywell'are registered ay..+...r•.• trademarks of Honeywell C ' IONa M l International,Inc. a ... SBUS ' + E it This document is not _.. - n -..x�w+• '--:�. '��- •: - intended to be used for 6860 5860 5860 installation purposes.We try to keep our product •Up to Eight 5860s Per 5700 or 6700 System information up-to •Up to 12 5860s Per 5808,6808.5820XL,or 5820XL-EVS System date and accurate.We •Up to 16 5860s per 6820 or 6820EVS System cannot cover all specific Compatible Silent Knight FACP P applications or anticipate all requirements.All specifications are suhject to change without notice. For Technical Support, 5860 Features call 800 446 6444. PHYSICAL ORDERING INFORMATION Dimensions:9.1"W x 7.4"H x 1.5"D(23.1W x 18.8H x 5860:Remote Annunciator,four line(4x20)LCD 3.8D cm) annunciator with 20 characters per line.Gray Shipping Weight:2.8 lbs(1.3 kg) 5860R:Remote Annunciator,four line(4x20)LCD Color:5860R Red,5860:Gray annunciator with 20 characters per line.Red ENVIRONMENTAL ACCESSORIES Operating Temperature:32°F to 120°F(0°C to 5860TR:Red Trim Ring for surface mounting 49°C) 5860TG:Gray Trim Ring for surface mounting Humidity:10%-93%non-condensing) AGENCY LISTINGS AND APPROVALS ELECTRICAL UL,iisted Operating Voltage:24VDC CSFM approved Standby Current:20mA Meets NFPA 72 requirements Alarm Current:25mA FM approved MEA approved For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Ceywenl nt dight Honeywell 122 Clintonvilleville Road Northford.CT 06472 Doc 3502241 Rev J 112v p SILENT 800-328-0103 c 2017 Honeywell International Inc KNIGHT Honeywell SILENT KNI >EVS-100W Intelligent 50/100 Watt Amplfier with optional backup Amplifier The EVS-100W is an intelligent 50/100 watt amplifier for use with Version 14.0 or newer 5820XL-EVS or the 6820EVS.The EVS-100W is used to amplify audio message for distribution throughout a facility.The EVS- 100W is capable of producing up to 100 watts of audio power and has the ability to provide an option for 50 watts of backup power. Description The EVS-100W has its own power supply with battery backup and eight speaker circuits.The EVS-100W is fully supervised by the main panel for trouble conditions EVS-100W Amplifier Configurations: • 50 watts with 50 watts as backup. • 100 watt single channel. • 100 watt single channel with 50 watts backup using EVS-IOOWBU • COMPATIBILITY The EVS-100W is compatible with the following Honeywell Silent Knight Series FACPs: • 6820EVS:Addressable fire alarm control panel with an emergency voice system,up to 1,110 addressable points,and four programmable buttons that can be programmed for routine or complex tasks • • 5820XL-EVS:Addressable fire alarm control panel with an emergency voice systems and up to 792 addressable points FEATURES BENEFITS • Built in backup Amplifier Bandwidth • Can be mounted up to • UL listed for • 120 VAC or 240 VAC amplifier test feature 400 Hz to 4000 Hz 6000 feet away from Continuous or ANSI operation allows you to . Six-wire connection to 5820XL-EVS or 520Hz speaker tones physically test that the • 6820EVS control that meet NFPA 72 EVS system:Two-wires backup amplifier is for the voice bus and panel Low Frequency Signal operating property four-wires for the • UL 864 and UL 2572 Requirements for • Up to four amplifiers SBUS connections Sleeping Areas.See per 5820XL-EVS or the FACP manual for a 6820EVS distributed • list of compatible between up to 32 speakers audio circuits • EVS-100W Technical. Specifications Fora complete listing of all compliance approvals and PHYSICAL ORDERING INFORMATION certifications.please visit www.silentknight.com. Flush Mount Dimensions:14.5"W x 24.75"H x EVS-100W:Intelligent 50/100 Watt Amplifier 3.4"D(36.8 W x 62.9 H x 8.7 D cm) Microsoft,Windows,and Overall Dimensions:16.1"W x 26 5"H x 4.1"D(40.6 ACCESSORIES the Windows Logo are W x 66.7 H x 10.5 D cm) EVS-100WBU:External Backup Amplifier registered trademarks or trademarks of Color:Red RBB:Remote Battery Box Accessory Cabinet.Use Microsoft Corporation. for backup batteries up to 35AH ENVIRONMENTAL Silent Knight"and Operating Temperature:32l -120N1(0l - AGENCY LISTINGS AND APPROVALS Honeywell' are registered trademarks of Honeywell 49E ) UL 864 and UL 2572 International,Inc. Humidity:10%-93%non-condensing Meets the requirements for NFPA 72 Local Protective Signaling Systems&Emergency This document is not ELECTRICAL Communication Systems. intended to be used for installation purposes.We Primary AC:120VAC a-60Hz;240VAC®50Hz CSFM:7165-0559:0500 try to keep our product Standby Current:EVS-100W 25V 110mA;EVS- information up-to 100W 70.7V 110mA date and accurate.We Alarm Current:EVS-100W 25V,1.2A;EVS-100W - cannot cover all specific 70.7V,1.4 A applicationsor anticipate all requirements.All Total Power:100 W:a 25 VRMS or 70.7 VRMS specifications are subject •Circuit 1-4:50 W max. to change without notice. •Circuit 5-8:50 W max. For Technical Main EVS Panel SBUS Standby&Alarm:10mA Support,Please call Battery Charging Capacity:7-35AH 800 446 6444_ Battery Size:18AH max allowed in cabinet.Use RBB accessory cabinet for larger batteries up to 35 AH per system. Voice Integration Wiring: • Six conductor • Two voice bus • Four SBUS • For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight Honeywell 12 Clintonville Road SUM Northford,CT 06472O� Doc 3509611 Rev El 05/16 800-328-0103 ()2018 Honeywell international Inc. Honeywell ® ENT' KNIGHT 5496 • Intelligent Power Module The 5496 intelligent power module is the most cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor^",Gentex6, AMSECO,and Wheelock'.The 5496's advanced microprocessor design is years ahead of the competition.Its switch mode power supply design is up to 50%more efficient than competitive linear mode power supplies. The 5496 is a 6 amp notification power expander that provides its own AC power connection,battery charging circuit,and backup battery for use with the Honeywell Silent Knight series fire alarm control panels(FACPs).The 5496 is the cost-effective solution for powering • MmnrJw4.11 notification appliances required by the Americans with Disabilities Act u • (ADA).The 5496 has built-in ANSI cadence pattern.The output circuits • can be programmed as notification appliance circuits,or as auxiliary power(configurable for constant,resettable,or door holder power). H°nctmeI 'I Compatibility 5496 The 5496 is compatible with the following Honeywell Silent Knight FACPs: • 6820/6820EVS • 5820XL/5820XL-EVS - • 6808 • 6700 • 5808 • 5700 • Cistedfor 6 amps • Built=m •NACs are . •communicates to the '� Lightwer design of notification power synchronization for programmable as FACP via 4-wire SBUS adds to ease of • Power su l s appliances from notification appliance (wire runs up to 6000 installation and advanced switch modeCentex,AMSECO, circuits,or as auxiliary ft) reduces shipping System Sensor,and power to be used as costs design reduces • AC toss delay option damaging heat and Wheelock constant,resettable, shuts off power to • ANSI Cadence pattern manages power up to • Four power-limited or door holder power non-essential high output capability 50%more efficiently notification outputs;2 • 3 amps per output current accessories built-in than other systems Class A or 4 Class B,or circuit like magnetic door • UL 864,1481&1971 1 Class A and 2 Class holders • 24 VDC filtered output • Ground fault detector listed voltage •• CSFM approved MEA approved • OSHPD(CA) OSP-0065-10(see accessories) 5496 Technical Specifications For a complete listing of all compliance approvals and certifications,please visit 4 Outputs Programmable www.silentknight.com. as Notification Appliance Circuits, Microsoft.Windows,and or as Auxiliary Power the Windows Logo are registered trademarks trademarksor ftC of Output 1 M SBUS Communication Microsoft Corporation To a Compatible . Honeywell"are KnightFACP System Sensor"and Honeywe are registered Output 2 10., trademarks of Honeywell International.Inc Output 3 41111 This document is not intended to be used for Output 4 installation purposes.We p try to keep our product information up-to date and accurate.We Auxiliary Power Can Be cannot cover all specific Programmed To Be Constant, applications or anticipate Resettable, or Door Holder Power all requirements.All specifications are subject to change without notice. For Technical Support. call 800-446-6444 PHYSICAL required on each Class B circuit Overall Dimensions: 16"H x 12.25"W x 3"D(40.6 x Battery Charging Capacity:7.0-35.0AH 30.9 x 7.6 cm) Shipping Weight:8.71bs ORDERING INFORMATION 5496:Intelligent Power Module ENVIRONMENTAL Operating Temperature:32°F to 120°F (0°C to ACCESSORIES 49°C) RBB: Remote Battery Box Accessory Cabinet.16" Humidity:10 to 930/0 relative humidity(non- W x 10"H x 6"D(406 mm W x 254 mm H x 152 mm condensing) D) SK-SCK: Seismic Compliance Kit ELECTRICAL: AC Input:120VAC at 2.7A AGENCY LISTINGS AND APPROVALS Output:24VDC at 6A • CSFM approved Standby&Alarm Current:10mA Notification/Aux.Power Circuits:4 • NFPA 72 Output Configuration: • UL listed 2 Class A(Style Z) 4 Class B(Style Y) • FM approved 1 Class A&2 Class B • Amps Per Output Circuit:3.0(6.0 amps total) City of NY:429 90 E Vol XIV Notification Circuit Output:20.4-27.3VDC ra) 3.OA each End-of-Line Resistance:4.7k W EOL resistor For more information Learn more about Silent Knight's Product and other products available by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road NAne\(vvell Northford,CT 06472 V ��]] ���- B00-328-0103 D SILENT' Doc 3503871 Rev FI 11/17 KNIGHT www.silentknight.com ©2017 Honeywell International Inc. DSC From Tyco Security Products LTE Universal Wireless Commercial Fire Alarm Communicator LE4OIOCF Features That Make a Difference: • Uses LTE network for high- speed, reliable and low-cost communications to an IP receiver Ensure your installations are • Automatically switches to 3G future-ready, with LTE (HSPA/HSPA+) if LTE service is Due to rapidly-evolving cellular or 1 hour(NFPA72 2013/2016) not available technologies, 2G/3G network sunsets of the failure, or it can be used as Compatible with control panels are already on the horizon—with part of a multiple communications • that communicate using Contact some having already been completed. technologies(for example in ID or SIA(300 baud)formats Now's the time to adopt and adapt. conjunction with a DACT). When Switch to LTE today,to offer used as a back-up provision shall • Full event reporting customers long-lasting investment be made to monitor the integrity of • 4 on board inputs with NC, NO protection, and reduce your future each communication path and failure or SEOL supervision truck rolls. of any communications path shall The LE4010CF connects the alarm be annunciated at the supervising • 4 on-board outputs(open station and at the protected premises collector) control panel to the Cellular network and reports alarm signals directly to within not more than 24 hours of the • Activation and initialization a monitoring station receiver failure. via website or mobile (Sur-Gard System I-IP/II/IIVIV/5).The How it Works interface provided by C24 LE4010CF uses the Cellular network Communications to ensure low-cost, high-speed and The LE4010CF can be used as • View communicator status reliable alarm communications and is either a Sole Communicator or as a directly from your mobile phone compatible with control panels that Backup Communicator.When being to support on site or remote communicate using the Contact ID or used as a Sole Communicator the troubleshooting SIA(300 baud)format. LE4010CF will replace the phone line connection on the panel and • Compatible with Sur-Gard® The LE4010CF is compliant as soon as it detects that an alarm System I-IP/II/IIVtV/5 monitoring with the latest requirements for Y 5 needs to be transmitted it will send station receivers Communications Methods as per the alarm across the Cellular network UL864 and NFPA72 2010, 2013, • Includes UL listed power and 2016 editions. It can be used immediately.When being used as a supply, transformer and 7 Ah backup the communicator assesses in Fire Monitoring applications as a the connection to the PSTN phone rechargeable battery single communications technology, line, and only in the event of a phone • UL 864 listed in which case any failure of the line failure will it send all alarm traffic communications path shall be • CSFM listed annunciated at the supervising station across the Cellular network to the within 5 minutes(NFPA72 2010) monitoring station. communications Contact your DSC distributor. www.dsc.com I 1-888-888-7838 CSC • From Tyco Security Products In instances where the control panel does not support CSFM Listing Contact ID or SIA(300 baud),the LE401 OCF has inputs pre- Theset to transmit fire alarm,fire supervisory or system trouble. LE4010CF has been approved by the California State Are Marshal(CSFM)pursuant to Section 13144.1 of the California Alarm signals are transmitted directly without the need of Health and Safety Code. a clearinghouse to the IP linecard of the monitoring station receiver(Sur-Gard®System I-IP/II/III/IV/5). Ordering Information: Activating & Initializing the Unit > LE4010CF-AT Universal Wireless Commercial Activating and initializing the LE4010CF can be done using the Fire Alarm Communicator website interface provided by C24 Communications. Rate Plan No special tools are required. Cost-effective rate plans have been negotiated and are Mobile Site for Easy Installation and available through authorized master resellers. Contact your Comprehensive Maintenance monitoring station or visit www.connect24.com to find a master reseller. When used as a sole communicator, the C24 Communications mobile site(m.connect24.com) LE4010CF requires use of the 4MB(NFPA72 2010)or 500kB makes the installation a simple process and offers intuitive NFPA72 2013/2016) trouble-shooting features, cutting down on time and cost r rate plans to support the supervision requirements. allocated to maintenance. Specifications Dimensions 1 1-1/2"x 10"x 3" • .`_ - - (290 mm x 254 mm x 75 mm) C24Input Voltage 120 VAC vicasti ---� Current Draw 200 mA(standby) 1i 400 mA(transmitting) Operating Environment 32°to 120° F(0°to 49°C) Weight 12.8 lbs(5.8 kg) UL Listing The LE4010CF is UL listed under File S4019, Listing guide Optional Acessories UOXX, as a sole or backup communicator for Commercial Fire Model Description monitoring installations. When used as a sole communicator under NFPA72 2010 guidelines the LE4010CF will send LTE-15ANT 15 ft extension antenna its heartbeat once every 97 seconds ensuring that three LTE-25ANT 25 ft extension antenna heartbeats will be received at the supervising station within LTE-50ANT 50 ft extension antenna the 300 second window. When used as a sole communicator under NFPA72 2013/2016 guidelines the LE4010CF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the LE4010CF will monitor the other communication method(DACT)and send a daily test transmission to the supervising station. co 8N communications For product information www.dsc.com Product specifications and availability subject(c change wilhout nutlet,.Certain product names mentioned herein may be trade names and/or registered trademarks of oilier companies. C2018 Tyco Security Products AL3000LX Series Q Altronix® Power Supply/Chargers - Specifications Input Agency Listings Voltage 115VAC, 60Hz, 3.5A max. All Models: Fusing 5A/250V. UL: UL294 Access Control System Units. Outputs UL603 Power Supplies for Use with Voltage 12VDC or 24VDC selectable. Burglar-Alarms Systems. Current 2.5A power-limited continuous max. UL 1069 UL Listed Hospital Signaling and Protection Fused 3.5A/PTC 2.5A. Nurse Call Equipment. Other Overvoltage protection. UL1481 Power Supplies for Filtered and regulated. Fire Protective Signaling Systems. PTC protected outputs are auto-resettable. cUL: CSA C22.2 No.205 Signal Equipment. Back-up Battery (not included) AL3000LX, AL3000LXX and AL3000LXJ only: Capacity 7AH/12VDC (1 or 2 within enclosure). CSFM California State Fire Marshall Approved. 12AH/12VDC(requires larger"X" enclosure). 18AH/12VDC(requires larger "J" enclosure). Physical and Environmental 40 AH/65 AH (requires separate enclosure). Dimensions (H x W x D) Type Sealed lead acid or gel type. AL3000LX,AL3000LPD4(CB),AL3000LPD8(CB): Charging current 0.7A. 13.5"x 13"x 3.25" (342.9mm x 330.2mm x 82.6mm). Fuse Rating 15A @ 32VDC. AL3000LXX, AL3000LXPD16(CB): Failover Upon AC loss, instantaneous. 15.5"x 12"x 4.5" (393.7mm x 304.8mm x 114.3mm). AL3000LXJ: Supervision 18"x 14.5" x 4,625" (457.2mm x 368.3mm x 117.5mm). AC Failure Form "C"contacts. Product/Shipping Weight (approx.) Battery Form "C" contacts. Model Product Weight Shipping Weight AL3000LX 6,65 lbs. (3.1 kg) 8.45 lbs(3.83 kg) Indicators (LED) AL3000LXX 8.25 lbs. (3.75 kg) 10.55 lbs. (4.79 kg) Input 115VAC is present. AL3000LXJ(G) 11.5 lbs. (5.22 kg) 13.7 lbs(6.21 kg) DC Output Powered. AL3000LPD4(CB) 6.8 lbs. (3.1 kg) 8.6 lbs(3.9 kg) Battery Discharged or not connected. AL3000LPD8(CB) 6.9 lbs. (3.13 kg) 8.7 lbs(3.95 kg) _ AL3000LXPD16(CB) 8.55 lbs. (3.88 kg) 10.85 lbs. (4.92 kg) Temperature Operating 0"C to 49"C (32"F to 120"F). Storage -20"C to 70"C(-4"F to 158"F). Relative Humidity 85%+/-5%. BTU/Hr. (approx.): 12VDC: 15 BTU/Hr. 24VDC: 31 BTU/Hr. Altronix Corporation 1 140 58th St I Brooklyn, NY 11220 USA phone:+1 718.567.8181 I fax:+1 718.567.9056 I email:info@altronix.com I www.altronix.com Eir,SimplEx Fire Alarm Control Panel Accessories Listings* System Batteries, Sealed Lead-Acid; with Applications Reference for Battery Cabinets, and Battery Cabinets with Charger Features Rechargeable, sealed lead-acid batteries: • Lead-calcium grid structure with immobilized electrolyte in absorbent separator • Low maintenance with no need to add water — • Low self-discharge characteristics • One-piece,high impact polystyrene cell cover with high reliability dual seal construction • UL 924 recognized pressure relief valves Available in a variety of capacities: • Batteries for internal mounting range from 6.2 Ah up to 50 Ah,depending on control panel cabinet size • Larger batteries,up to 110 Ah,mount in external battery g`°°"°'- cabinets with models available with internal chargers Battery cabinets with chargers: • Battery cabinets with charger communicate with their connected fire alarm control panel and are available for 4100ES/4010ES/4100U Series and 4010 Series panels Descri•tion Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets Simplex*rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems -- applications.They are designed with immobilized electrolyte in an absorbent separator,allowing them to provide rated capacity on the first cycle. t Because of their sealed construction,packaging is allowed within the system electronics enclosure(see illustration on page 2).When this is applicable,the quantity of system cabinets and the battery wiring distances are both minimized. Where required,external battery cabinets can Remote Battery Cabinets are Available for be close-nippled to the control panel to house larger Larger Battery Requirements batteries with battery chargers available in some battery cabinet sizes. Battery Details (Continued) Battery Details Shipping. Sealed lead-acid batteries are shipped via Charging.These batteries are intended to be used with ground or sea transportation only.They are not shipped compatible Simplex battery chargers. via air. Series Connections.These batteries are required to be Disposal.Battery chemicals and materials can be connected in series to produce 24 V system voltage. recycled. Refer to information shipped with the battery or Battery sets must be of identical voltage,model number, on its case. Return to the battery manufacturer or to a appearance, and approximately the same date of similarly qualified battery processing facility for proper manufacture for proper operation. disposal. Testing.Battery capacity testing is recommended to be Seismic Activity Applications.Battery brackets are performed by using a sealed lead-acid battery tester available for systems tested for compliance with specific designed to withdraw a minimum of battery charge.The batteries.Please refer to data sheet S2081-0019 for preferred tester applies a variety of amplitude and details. duration controlled test pulses that compares terminal . Refer to details on page 4 and to the referenced individual product data sheets far agency voltage against those predicted for the specific battery listing status of battery cabinets and chargers.The batteries detailed in this document size.(Testing is available through your local Simplex meet the requirements of UL,ULC,and Factory Mutual for use with respective equipment product supplier.) battery chargers as listed on page 3.Contact your local Simplex product supplier for proper battery selection per system requirements.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. S2081-0006-22 10/2016 Battery Construction Reference Actual appearance will vary with battery size. Sealed outer cover Quick connect or post type terminal Vent hole (type varies with battery size) Potting material,black for negative,red for positive r IR (polarity is also clearly marked with+and-) _j u Pressure relief valve Inner cove .., Absorbent ator used III� to immobilize electrolyte I// Semi-permeable Lead-calcium grids 10 membrane separator Cell group 1101 Or Cell case(high impact polystyrene) Battery Size Specifications Capacity @ 20 Hour Height with Approximate Battery Model Discharge Rate Width* Depth* Terminals Weight" 2081-9272 6.2 Ah 6-1/8"(156 mm) 2-5/8"(67 mm) 4"(102 mm) 5.75 lbs(2.6 kg) 2081-9274 10 Ah 6"(153 mm) 4-1/16"(103 mm) 4"(102 mm) 9.2 lbs(4.2 kg) 2081-9288 12.7 Ah 6"(153 mm) 4"(102 mm) 4"(102 mm) 9 lbs(4.1 kg) 2081-9275 18 Ah 7-1/4"(184 mm) 3-3/8"(86 mm) 6-5/8"(168 mm) 14.3 lbs(6.5 kg) 2081-9287 25 Ah 6-5/8"(168 mm) 5"(127 mm) 7"(178 mm) 19.4 lbs(8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-1/2"(318 mm) 3-3/8"(86 mm) 7-1/16"(179 mm) 26.6 lbs(12.1 kg) typically for service) 2081-9276_> ("square"case, 33 Ah 7-3/4"(197 mm) 5-1/4"(133 mm) 6-3/4"(171 mm) 26.5 lbs(12 kg) use for new) 2081-9296 50 Ah 9"(229 mm) 5-1/2"(140 mm) 8-7/8"(225 mm) 41.8 lbs(19 kg) 2081-9279 110 Ah 11-3/16"(284 mm) 10-1/2"(267 mm) 9"(230 mm) 82 Lbs(37 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary.Refer to the tables on page 3 for mounting compatibility.These batteries are 12 V each and series connected for 24 V system use. NOTE: When wired in series for 24 V output,these batteries are to be of identical voltage,appearance,model number,and approximately the same date of manufacture. General Battery Specifications Nominal Voltage Rating 12 Volts per battery Discharge Rating 20 Hour Rate Typical Charge/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60°F to 90° F(15.6°C to 32.2°C) 2 52081-0006-22 10/2016 Battery Compatibility for Fire Alarm Control Panel Mounting NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Simplex Control Panel Model Series(see legend and notes below) Battery Capacity Model 4007ES& 4006& 4009 4100ES/ 4100&4120 4003EC 4004R 4005 4008 (all models) 4010 4010ES 4100U (2,4 or 6-Unit) 2081-9272 6.2 Ah ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ I 2081-9274 10 Ah I I ✓ ✓ I I I I ✓ 2081-9288 12.7 Ah ✓ I ✓ ✓ ✓ ✓ ✓ ✓ ✓ 2081-9275 18 Ah Ext Note 3 ✓ Ext Ext Note 2 ✓ ✓ It 2081-9287 25 Ah Ext Note 3 Ext Ext NA ✓ ✓ ✓ ✓ 2081-9271 33 Ah Ext Note 3 Ext NA NA Note 3 ✓ ✓ Ext rectangular 2081-9276 33 Ah Ext Note 3 NA NA NA Note 3 ✓ ✓ ✓ "square" 2081-9296 50 Ah NA Note 3 NA NA NA Note 3 Note 6 2 or 3 bay Ext 2081-9279 110 Ah Requires external battery cabinet,compatible with 4100ES,4010ES,4100, and 4120 Series only ✓ =Can be placed in the respective equipment cabinet Ext=External battery cabinet is required, refer to selection chart on page 4 NA=Not applicable/not compatible NOTES: 1. These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 2. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. 3. Use 4081 series companion cabinet and charger, refer to page 4. 4. Some control panel models are listed for battery replacement reference only. 5. For 2 bay international applications only, 50 Ah batteries will fit in the cabinet. External Battery Cabinet Compatibility Reference Battery Cabinets without Chargers (connects to charger in panel) Battery Cabinet Panel Compatibility 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 18 Ah* 25 Ah Rectangular 33 Ah Square 33 Ah 50 Ah 110 Ah 2081-9280 4100ES,4010ES, NA NA NA NA NA ✓ 41000,and 4100+ 2081-9281 multiple ✓ ✓ ✓ ✓ ✓ NA 2081-9282 4009-9801 multiple ✓ ✓*- NA NA NA NA 4009-9802 multiple I NA ✓ NA NA NA Battery Cabinets with Chargers 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 Cabinet Panel Compatibility 18 Ah* 25 Ah Rectangular 33 Ah Square 33 Ah 50 Ah 110 Ah 4081-9301 4004R and 4010 ✓ ✓ ✓ ✓ ✓ NA 4081-9302 4081-9306 4100ES,4010ES, NA NA NA NA ✓ ✓ 4081-9308 and 4100U "Batteries smaller than those listed are normally mounted in the product cabinet ,t 25 Ah capacity was effective as of 7/2005. ✓=Can be placed in the respective equipment cabinet NA=Not applicable/not compatible 3 S2081-0006-22 10/2016 External Battery Cabinet Specification Reference Battery Cabinets Without Chargers; Shallow Design with Front Door Model Color Listings Description Dimensions 2081-9281 Beige UL and 2-Unit,4100 style cabinet without charger; with locking 25-3/4"W x 20-3/4"H x 6-3/4"D solid door and battery shelf, primarily for use with 50 Ah 2081-9282 Red FM batteries (654 mm x 527 mm x 171 mm) 4003-9860 Beige Multiple Intended for use with 4003EC systems,for up to 33 Ah 9-1/2"H x 24"W x 9"D batteries(refer to 4003EC data sheet S4003-0002) (241 mm x 610 mm x 229 mm) 4009-9801` Beige UL and For up to 25 Ah External battery cabinet without charger, 16-1/4"W x 13-1/2"H x 5-3/4"D FM batteries" with locking solid door and battery (413 mm x 343 mm x 146 mm)* 4009-9802 Bei a UL For up to 33 Ah harness;for close-nippled mounting to 25-3/4"W x 20-3/4"H x 4-1/8" D 9 batteries fire alarm control panel cabinet (654 mm x 527 mm x 105 mm) *Depth increased for 25 Ah batteries effective 7/2005. Chargers for use with 4010 Fire Alarm Control Panels and 4004R Suppression Release Systems (refer to data sheet S4081-0001) Model Color Input Voltage Description Dimensions 4081-9301 Beige Battery cabinet with charger for the 4010 and 4004R fire alarm control panel;for up to 50 Ah 120 VAC batteries;with front door 22-1/2"W x16-3/4"H x 8-3/8"D Listings include:UL, ULC, FM, CSFM, and MEA (572 mm x 425 mm x 213 mm) 4081-9302 Red g (NYC), see data sheet for details Battery Cabinet Without Charger for 110 Ah Batteries;for use with compatible panel mounted chargers (refer to data sheet S2081-0012) Model& Color Cabinet Description Compatible Charger Description Dimensions Listings Chargers 4010-9xxx 4010ES Main System Supply Series (MSS) 4100-9xxx 4100ES/41000 System Power Series Supplies(SPS) Battery cabinet for 4100-5111 2081-9279, 110 Ah 4100-5112 4100ES/4100U Additional SPS 2081-9280 batteries; includes 4100-5113 Listings Red 80 A battery fuse, 4100-5125 26-1/2"W x 12"H x 12"D include: UL terminals and 4100-5126 4100ESI41000 Remote Power (673 mm x 305 mm x 305 mm) and CSFM battery connection 4100-5127 Supply(RPS) cables;see data 4100-5120 sheet for details 4100-5121 4100ES/41000 TrueAlert 4100-5122 Addressable Power Supply(TPS) 4100-0104 4100-0114 4100 Legacy power supplies 4100-0124 4100ES/4010ES/41000 Compatible Battery Cabinet With Charger for 110 Ah Batteries (for ULC listed systems and for other applications unable to use panel mounted power supply charger; refer to data sheet S4081-0002) Model Color Input Voltage Description Dimensions Battery cabinet with charger for up to 110 Ah 4081-9306 Red 120 VAC batteries; NOTE: Required for ULC listed charging of 27-7/8"W x 13-1/2"H x 14-5/8"D 220/230/240 VAC, 110 Ah batteries;Listings include:UL, ULC, FM, (708 mm x 343 mm x 371 mm) 4081-9308 Red multi-tapped CSFM, and MEA(NYC),see data sheet for details 4100-9837 Green LED Power-on Indicator Kit,required for ULC listing,mounts above access panel using knockout provided TYCO,SIMPLEX and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited. i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S2081-0006-22 10/2016 www.sim pl ex-fire.corn ©2014 Tyco Fire Protection Products.All rights reserved.All spec fcations and other information shown were current as ojdocument revision date and are subject to change without notice Honeywell ®SILENT' KNIGHT SK-PHOTO, SK-PHOTO-T, and SK-PHOTOR Intelligent Photoelectric Smoke Detectors The SK-PHOTO is a photoelectric smoke detector,the SK PHOTO-T is a photoelectric smoke detector with thermal and SK-PHOTOR is a photoelectric detector with remote test capability.These plug in smoke detectors,with integral communication,provide features that surpass conventional detectors and are for use with the Honeywell Silent Knight series fire alarm control panels(FACPs). SK-PHOTO and SK-PHOTO-T are plug-in type smoke sensors that combine a photoelectric sensing chamber with addressable analog communications. Point ID capability allows each detector's address to be • set with rotary address switches,providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK-PHOTO(BASE INCLUDED) SK-PHOTO and SK-PHOTO-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources.In the SK-PHOTO-T,dual electronic thermistors add 135ei (572E) thermal technology to maximize detection. The SK-PHOTOR is a remote test capable detector for use with-the DNR/ DNRW duct smoke detector(not included). COMPATIBILITY SK-Photo,and SK-Photo-T are compatible with the following detector bases: B210LP:6"base(included) B501:2 wire base B224RB:Relay base B22481:Isolator base AT _ , ,> sl • Sleek,low-profile • Superior EMI • Detector transmits • Plug-in mounting • Listed for use in duct design resistance for signal to indicate provides ease of applications • Base included reliability maintenance is installation required • Rotary address • Reliable analog communications for for code compliance • Optional remote LED available on mounting installation trouble-free operation • Variety of mounting annunciator(System bases • UL Listed options to meet anySensor'PN RA100Z) • Age resistant polymer • housing application FM Approved • Dual electronic • Dual LED indicators thermistor design on for 3601Elisibility the SK-Photo-T SK-PHOTO, SK-PHOTO-T and SK-PHOTOR Technical Specifications listingw compliance approvals and ;r .! certifications,please visit °` www.silentknight.com. Compatible FACP '^°��L�; `_ =i'�•f MFor icrosoft,acomplete Windos,and all the Windows Logo are RA1002ppBunep registered trademarks i ! ��� or trademarks of � f Microsoft Corporation. r r Silent Knight° System Sensor'and Hone well y t. ,ni are registered ■ trademarks of Honeywell Nit jInternational,Inc.% This document is not Y intended to be used for Cow A DatmnalwKny installation purposes We try to keep our product Wiring SKSeeiee Detector Moonono eases information up-to date and accurate.We PHYSICAL cannot cover all specific ACCESSORIES applications or anticipate Height:2.0"(5.0 cm) RA100Z:Remote LED annunciator all requirements.All Diameter:4.1"(10.4 cm)installed in B501 base XR2B:Detector removal tool.A removal and specifications are subject replacement plug-into change without notice. p detectors. ELECTRICAL Includes the T55-127-000 For Technical Sup port, Operating Voltage:15-32VDC M02-04-01:Detector test magnet. call800-446-6444. Standby Current:304A to 24VDC Maximum M02-09-00:Test magnet with telescoping handle Alarm Current:6.5mA ck 24VDC max(with LED on) XP-4:Extension Pole for XR2B.Extends from 5- 15 ft. ENVIRONMENTAL T55-127-000:Detector Removal Head Operating Temperature BCK-200B:Black Detector Kit.For SK series SK-Photo:320-120Eff(Ols-49ECC) detectors SK-Photo-T:32l -10010 (0E-38E(C) Humidity:10%-93%non-condensing COMPATIBILITY The SK-PHOTO,SK-PHOTO-T and SK-PHOTOR OTHER RATINGS are compatible with the following Honeywell SK-Photo-T Thermal:Fixed temperature set point Silent Knight fire alarm control panels: 135E1(57n) 6820:Addressable fire alarm control panel Velocity:0-4000 fpm(0-20 m/sec) 6820EVS:Addressable fire alarm control panel with an emergency mass notification system. INSTALLATION 6808:Addressable fire alarm control panel The SK-PHOTO and SK-PHOTO-T plug into a 6700:Addressable fire alarm control panel compatible Silent Knight series detector bases.The 5700:Addressable fire alarm control panel SK-PHOTOR is a remote test capable detector head 5808:Addressable fire alarm control oanel included within the DNR(W)duct smoke detector. 5820XL:Addressable fire alarm control panel ORDERING INFORMATION 5820XL-EVS:Addressable fire alarm control panel �EK-PHOTO:Photoelectric smoke detector with an emergency mass notification system. SK-PHOTO-T:Photoelectric smoke detector with thermal(135'F fixed temperture) SK-PHOTOR:Photoelectric detector with remote test capability For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight Honeywell 12 Clintonville Road Northford.CT 06472 Doc 3501181 Rev Gl 11/17 D 800-326-0103 xr 2017 Honeyweil International Inc. GHT Honeywell ®SILENT' KNIGHT SK-HEAT, SK-HEAT-HT, and SK-HEAT-ROR Addressable Thermal Heat and Rate-Of Rise Detectors The SK-HEAT,SK-HEAT-HT,and SK-HEAT-ROR are plug in thermal detectors,with integral communication,that provide features that surpass conventional detectors.These thermal detectors are for use with the Honeywell Silent Knight series fire alarm control panels(FACPs). SK-HEAT,SK-HEAT-HT and SK-H EAT-ROR are intelligent sensors that utilize a state-of-the art thermistor sensing circuit for fast response. • Sensitivity is continuously monitored and reported to the FACP.Point ID capability allows each detector's address to be set with rotary address switches,providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK-HEAT is a fixed temperature sensor that uses a thermistor sensing • circuit to produce 135e: (57E(C)fixed temperature alarm.SK-HEAT-HT is a SK-HEAT(BASE INCLUDED) variable high temperature detector that provides high temperature detection at 135°F-190 ei (57°C-88°C).SK-HEAT-ROR is a rate-of-rise temperature sensor with 135C (57E(C)fixed temperature alarm. COMPATIBILITY SK-HEAT,SK-HEAT-HT,and SK-HEAT-ROR are compatible with the following detector bases: 8210LP:6"base(included) B501:2 wire base B224RB:Relay base B22481:Isolator base B200SR:Sounder base • F E A I U P.. Y-_ i B r- N E F I T S • • Reliable analog • Variety of mounting • Plug-in mounting • Tamper-proof feature communications for options to meet any provides ease of available on mounting trouble-free operation application installation bases • Age resistant polymer • Dual LED indicators • Optional remote LED • Rotary address housing for360tisibility annunciator(System switches for fast • Innovative thermistor • Detector transmits Sensor PN RA100Z) installation sensing circuit signalto indicate • UL Listed • Superior EMI maintenance is resistance for required reliability SK-HEAT, SK-HEAT-HT and SK-HEAT-ROR Technical Specifications PHYSICAL ORDERING INFORMATION For a complete listing of all Height:2.0'(5.0cm) > SK-HEAT:Fixed thermal detector(135°F) compliance approvals and Diameter:6.1"(155mm)installed in B201LP base SK HEAT ROR:Fixed rate of rise detector(135°F) certifications,please visit Shipping Weight:4.8oz(137 wwwsitentknight.com. g) SK-HEAT-HT:Fixed high temperature thermal detector(190°F) Microsoft,Windows,and ELECTRICAL the Windows Logo are Operating Voltage:15-32VDC Peak ACCESSORIES registered trademarks or f Standby Current:300pA ra 24VDC RA100Z:Remote LED annunciator MicrosofttrademarksCorporation. o Miosft Corporation. LED Current:6.5mA(y 24VDC max RMK400:Recesses mounting kit.Provides low profile for use with B501 Silent Knight System ENVIRONMENTAL XR2B:Detector removal tool.A removal and are registered and Honeywell so Operating Temperature replacement tool for SK series plug-in detectors. trademarks of Honeywell ISK-HEAT&SK-HEAT-ROR:-4®-100el (-207E ncludes the T55 127 000International lnc. 38w) M02-04-01:Detector test magnet. ThSK-HEAT-HT:-4�+ 1505(1(-20M-66NE) M02-09-00:Test magnet with telescoping handle s document is not g p g intended to be used for Humidity:10%-93%non-condensing XP-4:Extension Pole forXR2B.Extends from 5- installation purposes.We 15 ft. try to keep our product THERMAL RATINGS T55-127-000:Detector Removal Head information up-to SK-HEAT:Fixed temperature alarm BCK-200B:Black Detector Kit.For SK series caneotcaccurate.We specific i 1353F(57DC) appnotconerallnticip t detectors applications or anticipate SK-HEAT-HT:High temperature heat sensor 135°F all requirements All -19012E(57°C-887C) COMPATIBILITY specifications are subject The SK HEAT,SK-HEAT-HT and SK HEAT ROR SK-HEAT-ROR:Rate-of-rise detection 15DF/minto change without notice. (8.37C/min) are compatible with the following Honeywell For Technical Support, Silent Knight fire alarm control panels: call800-446-6444. 6820:Addressable fire alarm control panel 6820EVS:Addressable fire alarm control panel with an emergency voice system. 6808:Addressable fire alarm control panel 6700:Addressable fire alarm control panel 5700:Addressable fire alarm control panel 5808:Addressable fire alarm control panel 5820XL:Addressable fire alarm control panel 5820XL-EVS:Addressable fire alarm control panel with an emergency voice system For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Honeywell 800 328 0103 Doc 350120 I Revo olds171 KNIGHT SILENT r9 2018 Honeywell International Inc. INSTALLATION AND MAINTENANCE INSTRUCTIONS � SYSTEM�$ SENSOR® 3825 Ohio Avenue,St. Charles,Illinois 60174 I-800-SENSOR2,FAX:630-377-6495 �=AB501 Plug-in Detector Base www.systemsensor.com SPECIFICATIONS Diameter: 4.0 inches(10.2cm) Mounting: 50mm,60mm,and 70mm centers Electrical Ratings-includes base and detector Voltage Range: 15 to 32 VDC Standby Current(Nominal): 150pA at 24 VDC Power-Up Surge at Max. Rated Voltage: 1.5mA-Sec. LED Current(Nominal): 6mA at 24 VDC Operating Temperature Range: Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at http:\\www.systemsensor.com BEFORE INSTALLING For signal wiring(the wiring between interconnected detectors and modules), Please thoroughly read the System Sensor manual, System Smoke Detectors it is recommended that the wiring be no smaller than 18 gauge (1.0 square Application Guide, which provides detailed information on detector spacing, mm). Wire sizes up to 12 gauge wire (2.5 square mm) may be used with the placement,zoning,wiring,and special applications.Copies of this manual are base. For best system performance,the power(+) and (-I loop wires should available at no charge from System Sensor. be twisted pair or shielded cable installed in separate grounded conduit to GENERAL DESCRIPTION protect the loop from extraneous electrical interference.If a cable shield is pro- The B501 is a plug in detector base intended for use in an intelligent system with aided,the shield connection to and from the base must be continuous by us- screw terminals provided for power(+)and (-),and remote annunciator con- mg wire nuts,crimping,or-soldering as appropriate for a reliable connection. nections.The communication takes place over the power(+)and(-)lines. Wire Connections are made by simply stripping about'/s of an inch of insula- BASE TERMINALS tion from the end of the wire (use strip gauge molded in base), sliding the No. Function bare end of the wire under the clamping plate and tightening the clamping plate screw.Do not loop the wire under the clamping plate. 1 Power(-),Remote Annunciator(-) 2 Power(+) The zone wiring of the detector base should be checked before the detector heads are installed in them.The wiring should be checked for continuity,po- 3 Remote Annunciator(+) larity in the base,and dielectric tests. FIGURE 1.TERMINAL LAYOUT: The base contains a label to write the zone, address,and type of detector to TAMPER PROOF be installed at that location.This information is used to set the address of the _.„---." TAB detector head that will later be plugged into the base and to verify the type BASE i 21�=� required for that location. TERMINAL cV • FIGURE 2.TYPICAL WIRING DIAGRAM FOR 2-WIRE LOOP: REMOTE CAUTION: DO NOT LOOP WIRE ANNUNCIATOR UNDER TERMINAL 1 OR O I E - _� BREAK WIRE RUN TO PROVIDE SUPERVISION OF CONNECTIONS. ile/ii it., / � : 2 + CO 1 ft jo ,,,,,i • �� ( ) az \ �o 1 71V / 1 I':A 1-6D 0 CLASS A OPTIONAL WIPING /— CO133-00 y TAMPERPROOF FEATURE t� NOTE:Do Not use the tamper-resistant capability if the XR2 or XR2B Removal t'O Tool will be used. This detector base also includes an optional tamperproof feature that when activated prevents removal of the detector without the use of a tool. To activate this feature,simply break off the tab on the detector base shown in Col31-0o Figure 3A,and install the detector.To remove the detector from the base once WIRING INSTALLATION GUIDELINES(SEE FIGURE 2) the tamperproof feature has been activated,place a small-bladed screwdriver All wiring must be installed in compliance with the National Electrical Code into the small hole on the side of the base and push the plastic lever away from the detector head (see Figure 3B). This will allow the detector to be ro- and the local authority having jurisdiction. Proper wire gauges should be used. The conductors used to connect the smoke detectors to control pan- tated counterclockwise for removal. els and accessory devices should be color-coded to prevent wiring mistakes, The tamperproof feature may be defeated by breaking and removing the plas- Improper connections can prevent a system form responding properly in the tic lever from the base,however this prevents ever using the feature again. event of a fire. D550-02-00 I 156-0357-008R REMOTE ANNUNCIATOR(RA400) The remote annunciator is connected between terminals 1 and 3 using the spade lug terminal packed with the remote annunciator. The spade lug termi- nal is connected to the base terminal as shown in Figure 4. It is not acceptable to have three stripped wires under the same wiring termi- nal unless they are separated by a washer or equivalent means.The spade lug supplied with the model RA400 is considered an equivalent means.See Figure 2 for proper installation. FIGURE 3A.ACTIVATING TAMPERPROOF FEATURE: PLASTIC LEVER BREAK TAB AT DOTTED LINE BY • TWISTING TOWARD CENTER OF BASE. C0132-00 FIGURE 3B. REMOVING DETECTOR HEAD FROM BASE: SCREWDRIVER TO PRESS PLASTIC LEVER IN DIRECTION OF ARROW / C11132-00 FIGURE 4.CONNECTION TO REMOTE ANNUNCIATOR TERMINAL; STRIPPED WIRE u / \\ - L\\\ WIRE WITH SPADE LUG C0116-00 Please refer to insert for the Limitations of Fire Alarm Systems THREE-YEAR LIMITED WARRANTY System Sensor warrants its enclosed smoke detector base to be free from detects in ma- Repair Department, NA a ,3825 Ohio Avenue. St. Charles,IL 60174. Please terials and workmanship under normal use and service for a period of three years from include a note describing the malfunction and suspected cause of failure.The Company date of manufacture. System Sensor makes no other express warranty for this smoke shall not be obligated to repair or replace units which are found to be defective because detector base.No agent,representative,dealer,or employee of the Company has the au- of damage, unreasonable use, modifications, or alterations occurring after the date of thority to increase or alter the obligations or limitations of this Warranty.The Company's manufacture.In no case shall the Company be liable for any consequential or incidental obligation of this Warranty shall be limited to the repair or replacement of any part of the damages for breach of this or any other Warranty,expressed or implied whatsoever,even smoke detector base which is found to be defective in materials or workmanship under if the loss or damage is caused by the Company's negligence or fault,Some states do not normal use and service during the three year period commencing with the date of mane- allow the exclusion or limitation of incidental or consequential damages,so the above facture.After phoning System Sensor's toll free number 800-SENSOR2 (736-7672) for a limitation or exclusion may not apply to you. This Warranty gives you specific legal Return Authorization number, send defective units postage prepaid to: System Sensor, rights,and you may also have other rights which vary from state to state. D550-02-00 2 I56-0357-008R ®2008 System Sensor Honeywell SILK MA KNIGHT >SK-DUCT Intelligent Air Duct Smoke Detector The SK-DUCT Intelligent air duct smoke detector is used with SK-PHOTOR (included)for detecting smoke and products of combustion present in air moving through an HVAC air handling system.When smoke is detected in a duct,the unit communicates the condition to the Honeywell Silent Knight control panel.The panel,in turn,depending on programming and wiring. x `;+ turns off fans,blowers,and other devices The duct housing allows for jn. mounting of SK-RELAY addressable relay module. — .. ., " The Model SK-DUCT Air Duct Smoke Detector utilizes photoelectric technology for the detection of smoke.It provides early detection of smoke and products of combustion present in air moving through HVAC ducts in SK-DUCT Commercial and Industrial applications. The SK-DUCT is in a heavy duty gray steel back box with a clear cover. It features a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. It installs quickly and easily. The unit senses smoke in the most challenging conditions,operating in airflow speeds of 100 to 4000 feet per minute,temperatures of-4°F to 158°F,and a humidity range of 0 to 95 percent(non-condensing). f__ TUPF s x BF_ NEf IS • Versatile mounting • Rugged steel back box • Patented sampling options:square or with clear plastic cover tube installs from rectangular • Easy to clean front or back of the configuration detector with no tools • Large terminal required • New Cover tamper connection screws signal • Available space within • LED alarm indication • Transparent cover for housing to convenient visual accommodate and communication inspection on sensor head mounting of relay module • Detects and limits the • UL listed spread of smoke SK-DUCT Technical Specifications For a complete listing of all PHYSICAL IMPORTANT NOTES: compliance approvals and (Rectangular):14.38"(37 cm)L X 5"(12.7 cm)W X •The use of either RTS151 or RTS151KEY certifications.please visit www.silentknight.com. 2.5"(6.6 cm)D requires the installation of an accessory coil, (Square):7.75"(19.7cm)L x 9"(22.9cm)W x 2.5"D DCOIL,sold separately.Please refer to the Microsoft,Windows,and (6.35cm) SK-DUCT installation instructions for more the Windows Logo are information Weight:1.61b(0.73kg) registered trademarksor trademarks of •The RTS151/RTS151KEY test coil circuit Microsoft Corporation. ELECTRICAL(using SK-Photo or SK-PhotoR) requires an external 24VDC power supply which Operating Voltage:15-32 VDC must he UL listed. Silent Knight`,System Sensor'and Honeywell' Standby Current:300µA @ 24 VDC max. ACCESSORY CURRENT LOADS AT 24VDC are registered Alarm Current:6.5 mA r 24 VDC max(with LED Device Standby Alarm trademarks of Honeywell on) International,Inc. RA100Z OmA 12rnA Max. This document is not ENVIRONMENTAL RTS151 OmA 12mA Max intended to be used for Operating Temperature:-4s4 —1581E(-20NE- installation purposes.We 70EL) RTS151KEY 12mA 12mA Max try to keep our product Humidity:0%-95%(non-condensing) information up-to date and accurate.We COMPATIBILITY cannot cover all specific AIR VELOCITY The SK-DUCT is compatible with the following applications or anticipate 100 to 4000 ft/min: (0.5-20.3 m/sec.) Honeywell Silent Knight fire alarm control panels: al:requirements.All 6820:Addressable fire alarm control panel specifications are subject ORDERING INFORMATION to change without notice SK-DUCT: Intelligent non-relay duct smoke 6820EVS:Addressable fire alarm control panel with an emergency mass notification system. For Technical.Support, detector 6808:Addressable fire alarm control panel call800-446-6444. SK-PHOTO: Addressable Photo Detector 6700:Addressable fire alarm control panel SK-PHOTOR: Addressable Photo Detector with 5700:Addressable fire alarm control panel remote test capability(included with SK-Duct) SK-RELAY: Addressable Relay Module,must be 5808:Addressable fire alarm control panel added if relay function is required,(fits in housing) 5820XL:Addressable fire alarm control panel 5820XL-EVS:Addressable fire alarm control panel ACCESSORIES with an emergency mass notification system. DST1: Metal Sampling Tube Duct Width up to 1' DST1.5: Metal Sampling Tube Duct Widths 1'-2' DST3:Metal Sampling Tube Duct Widths 2'-4' DST5: Metal Sampling Tube Duct Widths 4'--8' DST10: Metal Sampling Tube Duct Widths 8'-12' DH4000E-1: Weatherproof Enclosure ETX: Metal Exhaust Tube Duct width 1' RA100Z: Remote LED Annunciator DCOIL: Duct accessory coil,required if using with SK-PHOTO and not SK-PHOTOR(included)with SK-DUCT RTS151: Magnetic Remote Test station RTS151KEY: Key-Activated Remote Test station M02-04-00Test Magnet P48-21-00 Replacement End Cap for Metal Sampling Tube APA151:Remote annunciatorwith piezo alarm For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywel K 2 Clinton il Silent dight Honeywell 12 Clintonville Road Northford,CT 06472 Dec 3501221 Rev F 111/17 SILENT 800-328-0103 is 2017 Honeywell International Inc. KNIGHT Specifications, Duct Smoke Detector Accessories APA151 Piezo Annunciator RTS151 Remote Test Station Voltage Regulated 24 VDC Power Requirements Alarm LED:2.8 to 32 VDC, 12 mA max. Operating Voltage 16 to 33 VDC Total Current: 105 mA max. Maximum Alarm Current 30 mA Test Switch 10 VA 12132 VDC Temperature Range 0°C to 49°C(32°F to 120°F) Reset Switch 10 VA©32 VDC Relative Humidity 10 to 93%non-condensing Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range -10°C to 60°C(14°F to 140°F) Dimensions 4.6"H x 2.9"'W x.45"D Relative Humidity 95%non-condensing MHR/MHW SpectrAlerteAdvance Mini-Horns Wire Gauge 14 to 18 AWG Voltage Regulated 12 DC or FWR(Full Wave Dimensions 4.8"Fl x 2.90"W x 1.4"D Rectified)or Regulated 24 VDC or FWR RIS151 KEY Remote Test Station with Key Sounder Current Draw 22 mA RMS max.at 8 to 17.5 Volts DC Power Requirements Power LED(Green): 14 to 35 VDC, 29 mA RMS max.at 16 to 33 Volts DC 12 mA max. Temperature Range 0°C to 49°C(32°F to 120°F) Alarm LED(Red):2.8 to 32 VDC, Humidity Range 10 to 93%non-condensing 12 mA max. Nominal Sounder 3 kHz Total Current: 105 mA max. Frequency Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range -10°C to 60°C(14°F to 140°F) Relative Humidity 95%non-condensing Dimensions 4.6"H x 2.9'"W x 0.45"D RA100Z/RA100ZA Remote Annunciator Wire Gauge 14 to 18 AWG Voltage Range Conventional System:3.1 to 32 VDC Dimensions 4.6"H x 2.75""W x 1.8"D Intelligent System: 18 to 32 VDC RTS2 and RTS2-AOS Multi-signaling Accessory Maximum Alarm Current 10 mA Voltage 20 to 29 VDC Dimensions 4.6"H x 2.8"W x 1.3"D Power Requirements Standby:3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe.30 mA max. Alarm with strobe:55 mA max. Sounder 85 dBA at ten feet Temperature Range -10°C to 60°C(14°F to 140°F) Relative Humidity 95%non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8"W x 5.3"H x 1.6"D For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. riff 10 s. RTS151 UL S4011 RTS151KEVULS2522 APA151 UL S4011 R S' ),':S L ,.,„,;) <w b RA1002 UL S2522 MHW UL S4011 MHR UL S4011 AOS �� SYSTEM 3825 3825 Ohio Avenue•St.Charles, IL 60174 ®N or 13 System Sens . V SENSOR F Phone:800-SENSOR2•Fax:630-377-6495 Prod°0tap�xiaadcnsoubienrroa,angewahoutrr0000 Vise syst serSOe00 for current product IMomation.Including the latest version of fits data sheet. www.systemsensor.com HV0520202.8/13 Honeywell [�SILENT' illi KNIGHT SK-RELAY Intelligent Relay Module The SK-RELAY is an addressable relay module for use with Honeywell Silent Knight Series fire alarm control panels(FACPs).The SK-RELAY allows a Silent Knight FACP to switch discrete contacts by code command.The • relay contains two isolated sets of Form C contacts.which operate as a DPDT switch.No supervision is provided for the notification appliance circuit. Honeywell The SK-RELAY contacts can be used for virtually any normally open or KNIGHT normally closed application.Each SK-RELAY is programmed with a unique signaling line circuit(SLC)loop address.When an event occurs that controls the SK-RELAY,the relay is triggered by the FACP # #' INSTALLATION F ne SK-RELAY mounts directly into a 4"square electrical box.The box must SK-RELAY have a minimum depth of 2-1/8".A surface mount electrical box(System Sensor'PN SMB500)is available from Silent Knight. F I ,-2 I l) '_'. '> C BENEFITS • Two sets of Form C • Panel controlled • Polling LED visible contacts status LED that through the cover • Rotary address flashes green in plate switches for fast normal state and is . SEMS screws for easy installation solid red in alarm wiring • Contacts are rated for ' Relay programming is • UL Listed a variety of amps(see completely flexible- Specifications) can be mapped to zone conditions SK-RELAY Technical. Specifications For a complete listing of all compliance approvals and PHYSICALcertifications,pleasevisit ORDERING INFORMATION www.silentknight.com 4.675"H x 4.275"W x 1.4"D > SK-REIAY:Relay Module Shipping Weight:6.3 oz(196 y) Microsoft,Windows.and ACCESSORIES. the Windows Logo are ELECTRICAL registered trademarks SMB5O0:4"Square Surface Mount Electrical Box or rademarks of Operating Voltage:15-32 VDC C8500:Module Barrier Microsoft Corporation. End-of-Line Resistance:Not used SLC Standby&Alarm Current:.255mA max @? COMPATIBILITY Silent Knight ,System Sensor'and Honeywell' 24VDC(one communication every 5 sec with LED The SK-RELAY is compatible with the following are registered enabled) Honeywell Silent Knight fire alarm control panels: trademarks of Honeywell 6820:Addressable fire alarm control panel International,Inc. ENVIRONMENTAL 6820EVS:Addressable fire alarm control panel This document is not Operating Temperature:32 Qs -120e1 (0M- with an emergency mass notification system. intended to be used for 49M) 6808:Addressable fire alarm control panel installation purposes.We Humidity:10%-93%non-condensing 6700:Addressable fire alarm control panel tryto keep our product information up-to RELAY CONTACT RATINGS 5700:Addressable fire alarm control panel date and accurate.We 3.OA 4 30VDC resistive 5808:Addressable fire alarm control panel cannot coverall specific 5820XL:Addressable fire alarm controlpanel applications or nts. cipatc 0.9A t 110VDC resistive all requirements.All O.9A 125VAC resistive 582OXL-EVS:Addressable fire alarm control panel specifications are subject 0.5A 125VAC inductive(PF= 35) with an emergency mass notification system. to change without notice. 0.7A(4 75VAC inductive(PE=.35) For Technical Support, call 800-446-6444. For more information • Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honey veil Northford.CT 06472 �IGGe SSILL ENT' Doc 3501271 Rev GI 11/17 800-328-0103 ©2017 Honeywell International Inc. MA KNIGHT Honeywell [ SILENT 11641 KNIGHT PSK-MONITOR Intelligent Monitor Module The SK-MONITOR is an addressable monitor module for use with Honeywell Silent Knight Series fire alarm control panels(FACPs).The SK-MONITOR is intended for use in intelligent,two-wire systems,where individual address of each module is selected using the built-in rotary switches. The SK-MONITOR supports Class A supervised or Class B supervised wiring to the toad device.Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. ; INSTALLATIONr The SK-MONITOR mounts directly into a 4"square electrical box.The box must have a minimum depth of 2-1/8"-A surface mount electrical box (System Sensor' PN SMB500)is available from Silent Knight. SK-MONITOR TUPES BENEFITS • Single contact monitor • Panel controlled • UL Listed • Support for Class A status LED that • Rotary address and Class B wiring flashes green in switches for fast • normal state and is installation • Fully supervised solid red in alarm • SEMS screws for easy wiring • SK-MONITOR Technical Specifications For a compiete listing of all compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. Height:4.5"H x 4"W x 1.25"D(11.4 X 10.2 X 3cm) SK-MONITOR:Monitor Module Microsoft,Windows,and Shipping Weight:6.3 oz(196 g) the Windows Logo are ACCESSORIES. registered trademarks ELECTRICAL SMB500: Square surface mount electrical box or trademarks of Operating Voltage:15—32VDC Microsoft Corporation Current Draw(LED on):5.DmA max COMPATIBILITY Silent Knight",System Operating Current(LED flashing):375 A The SK-MONITOR is compatible with the p g g p followingHoneywell Silent Knight fire alarm are registered and Honeywell' Standby Current:400 µA max,at 24 VDC(one y g are control panels: trademarks of Honeywell communication every 5 sec with 47K EOL);550µA y 6820:Addressable fire alarm control panel International,Inc. max;a 24 VDC(one communication every 5 sec with EOL<1K) 6820EVS:Addressable fire alarm control panel This document is not 5.5 mA(with LED latched on) with an emergency mass notification system. intended to be used for LED Current:5.5 mA(with LED latched on) 6808:Addressable fire alarm control panel installation purposes.We End-of-Line Resistance:47K0 6700:Addressable fire alarm control panel try to keep our product information up-to Initiating Device Circuit Wiring Resistance:1,500 5700:Addressable fire alarm control panel date and accurate.We S2 max 5808:Addressable fire alarm control panel cannot cover all specific SLC Loop Resistance:405 max. 5820XL:Addressable fire alarm control panel applications or anticipate all requirements.All ENVIRONMENTAL 5820XL-EVS:Addressable fire alarm control panel specifications are subject with an emergency mass notification system to change without notice. Operating Temperature:326; —120f (0M— 49M) ForTechnicalSupport, Humidity:10%-93%non-condensing call800-446-6444. • • For more information Learn more about Honeywell Silent Knight and other products by visiting w.vw.silentknight.com HSilent Knight Honeywell 12 Clintonville Roac Northford,CT 06472 Doc 3501311 Rev G 111/17 • SILENT 800-328-0103 c0 2017 Honeywell International Inc. ®KNIGHT Honeywell Dsue. KNIGHT SK-PULL-SA / SK-PULL-DA Intelligent Pull Stations The SK-PULL-SA is a single action pull station requiring only one motion to activate the station.The SK-PULL-DA is a dual action pull station requiring FIRE two motions to active the station.The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel(FACP). { PULL iv DOWN DOWN Extremely easy to operate,the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal.The FACP recognizes each manual putt station by its specific address saving precious seconds in determining the location of an alarm. Honeywell . INSTALLATION The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-I/O SK-PULL-SA surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 213"(5.40 cm)or double gang or 4`(10.61 cm)square electrical box.You can also use the optional(System Sensor'PN BG-TR) FIRE trim ring if the station is being semi-flush mounted. ! PUSH IN II PULL DOWNS Honeywell . �. ,Lr a SK-PULL-DA FEATURES & BEl1 F ITS • Installer can open • Key operated test and • Meets the Americans • Reliable analog • Handle latches in station without reset lock using lock with Disabilities Act communications for down position and the causing an alarm plate actuator Accessibility trouble-free operation word Activated condition Guidelines(ADAAG) appears,clearly • Key matches • Braille text on station controls and operating indicating the station • Dual-color LED is compatible FACP handle mechanisms has been pulled visible through handle locks of station blinks green guidelines(Section • Rotary address • Meets ADA 4.1.3[13]) switches for fast • UL Listed,including to indicate normal requirement for 5 lbs installation UL 38,Standard of operation and remains maximum pull force to • Shell,door,and handle Manually Actuated steady red in an alarm active molded from durable Signaling System condition LEXAN • CSFM Listed • MEA Listed SK-PULL-SA / SK-PULL-DA Technical Specifications For a complete listing of all compliance approvals and PHYSICAL ORDERING INFORMATION certifications,please visit www.silentknight.com. Dimensions:5.5"H x 4'W x 1.45°D(14 x 10.2 x — SK-Putl-SA:Single Action Pull Station 3.7cm) SK-Pull-DA:Dual Action Pull Station Microsoft,Windows,and Housing Material:LEXAN potycarbonate resin the Windows Logo are registered trademarks Bi-Colored LED: ACCESSORIES or trademarks of Blinking Green:Normal BG-TR:Optional trim ring. Microsoft Corporation Steady Red:Alarm • SB-I/O:Surface backbox,indoor/outdoor. Silent Knight",System Switch:Single pole,single throw(SPST)normally *Unless otherwise noted,specifications apply to Sensor'and Honeywell" open(N/0)switch which closes upon activation of SK-Pull-SA and SK-Pull-DA are registered the pull station trademarks of Honeywell COMPATIBILITY International,Inc. ELECTRICAL The SK-PULL-SA AND SK-PULL-DA are This document is not Operating Voltage:15-32VDC compatible with the following Honeywell Silent intended to be used for SLC Standby and Alarm Current:3501.1A Knight fire alarm control panels: installation purposes.We Wire Gauge:Up to 12AWG(3.1 mm2) 6820:Addressable fire alarm control panel try to keep our product 682OEVS:Addressable fire alarm controlpanel date and d an up-to caccurate. ci ENVIRONMENTAL with an emergency voice system. cannot cover all specific Operating Temperature:32N-120V (OM- 6808:Addressable fire alarm control panel applications or anticipate 49M) 6700:Addressable fire alarm control panel all requirements.All spHumidity:10%-93%non-condensing 5700:Addressable fire alarm control panel tochangeiwit are subject change without notice. 5808:Addressable fire alarm control panel For 5820XL:Addressable fire alarm control panel 80 -446nical6o4A Support, call 800-446-6444 582OXL-EVS:Addressable fire alarm control panel with an emergency voice system For more information Learn more about Honeywell Silent Knight and other products by visiting wwwsilentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Doc 350135 1 Rev E 111/17 ®SILENT'800-328-0103 ei 2017 Honeywell International Inc. KNIGHT ■ss�:L�D1Qmmi STI STOPPER Il ® r„.., . _ t...4 Sul t 1�1.k, , , locAsE oF Fist NJ KEY FEATURES General Information Proven effective for more than "^++..w 35 years in helping stop false fire If alarms without restricting legitimate ` alarms. PULL Can be used as a guard against .. `; ,, physical damage to a manual pull station,with or without the optional ,'i warning horn. k r •Three year guarantee against a IN CASE OF breakage of polycarbonate in d normal use(one year on electro mechanical and electronic ''' " ,, I c �L us components). +t '� r +4 ADA Design fir=: rg BSA • Larger sizes and surface mounted —„ pull stations accommodated with FORME RETTAILSAILSVERSE p STI-3100 conduit spacer. SEE f' • Weather models have closed cell tHET' ,', gaskets. LIFTI 1 C—) trademark The Stopper II design is a registered trademark of Safety Technology ST1-1 ioo International,Inc. Construction PRODUCT OVERVIEW -UL Listed to U.S.and Canadian This protective cover has been helping to stop false fire alarms around the world for safety standards(also for custom more than 35 years, without restricting legitimate alarms.All models offer excellent labeling). protection against physical damage(both accidental and intentional)and several Installation •When covering a pull station against severe environments both inside and out. It is ideal for schools, colleges, outside,UL requires stations to be hospitals, nursing homes, stores, hotels and public buildings of almost every kind listed for outdoor use. where there is a threat of false alarms. •Typical working properties of polycarbonate are-40°to 250°F HOW IT WORKS (-40°to 121°C) Electronics Stopper II consists of a clear,tamperproof, tough polycarbonate shield and frame, but . Power source is a 9V DC alkaline the line includes models with the option of a piezo horn, spacer, Form "C"dry relay battery included on standard contact and gaskets.The cover accommodates most manual pull stations. When the Stopper II (remote powered unit available). Stopper II with horn is lifted to gain access to the protected alarm, a piercing self- Options contained 95 or 105 dB warning horn (at one foot)sounds. Immediate attention is . optional horn has a choice of 95 or drawn to the area and a prankster will either run or be caught.The cover is connected 105 dB at one foot. to the frame by a cable.When the cover is lifted, it drops off of the frame and a horn - Standard red units have"In Case ofwill sound (models with horn)until the cover is snapped back onto the frame or for the n Filab l label unless labespecl" with pP "no label"or"custom label"(extra life of the battery. charge for custom label). For more information,call 1-800-888-4784(4STI)or visit www.sti-usa.com Safety Technology International STI Stopper II® Dimensions and Technical Information MODELS AVAILABLE APPROVALS & WARRANTY Stopper II®Models Indoor Use TESTING ---->STI-1100* With horn for flush mount It has been tested and approved or listed by: STI-1130* With horn and spacer • UL/cUL Listed No.S2466 STI-1200* Without horn flush mount •For fire alarm applications,UL38 requires outdoor listed stations for STI-1230* Without horn with spacer outdoor use Weather Stopper®with gaskets(Indoor/Outdoor rated) •State of California(obtain local fire marshal approval) STI-1150* Stopper II with horn flush mount • MEA 49 00 E(STI-1200) STI-1155' Stopper II with horn and spacer •Flush models ADA Compliant.Surface models ADA Compliant for STI-1250' STI-1200 flush mount and gasket operation(UL Certified No.S2466) STI-3150* STI-1200 with spacer and gaskets i Weather Stopper6 versions designed to meet the requirements of IP54. Accessories •The indoor/outdoor rated station covers,when mounted on a KIT-316 Louvers for STI-3100 smooth surface, provide a rain tight seal similar to a 3R enclosure KIT-H19015 Two 3/16"Allen wrenches rating. STI-1102 Replacement horn for cover with alarm WARRANTY STI-1280 Backplate STI-3002 Weather gasket Three year guarantee against breakage of polycarbonate in normal STI-3003 Conduit gasket use(one year on electro mechanical and electronic components). STI-3004 Rigid conduit gasket STI-3100 2"conduit spacer with 1/2"or 3/"conduit entry IMPORTANT NOTICE STI-3104 2"conduit spacer with 1"or 3/4"conduit entry (includes one/"conduit entry gasket) Stopper IIde"FIRE"models are intendedsfrmto be used in areas where the incidence of false fire alarms from manual pull stations is high or *Add-NR for no label on horn housing has proven to be a serious problem.Any disadvantage of this device Add-CR for custom label on horn housing is more than balanced when one considers the consequences of Add-FR for French labeling false fire alarms,especially if fire service personnel and equipment Add-ES for Spanish labeling are responding to a false fire alarm when they are needed for a real fire somewhere else.Add to this the disruption to the facility when COVER false alarms occur.If you have,or may have,a problem with false f, _ - ; 4 fire alarms or physical/weather damage to your fire alarm activation I, 5.37 in. HORN HOUSING (137mm) I 3.nsi". devices,the Stopper II could prove invaluable. 1� 1 1 in.(81mm) + i? 6 in. f• �(25mm) *WARNING:LFor RC models:UL Listing does not permit relay 07 (15zmm) -ir contacts to connect to the fire alarm or a life safety function. The power supply for horns,according to UL Listing,cannot SPACER j ; (S2 in. be connected to a UL Listed fire alarm system.For electrical specifications see install book. RC models contain one set of Form 0, N. } "C"dry contacts.Contacts rated 30 VAC/VDC 1 amp. SIDE VIEW MODELS WITH HORN(STI-1100 Series) COVER r_-r 7 /' (136mm) i 3.175 in. 3 in. v�* 1 (81mm) (76mm)� 3.18 in. il S .5 in. d*�•• 4in. 2.73 in.(81mm) f i (13mm) / (102mm) \ 2.32 in. (70mm) �� 7.4 in. % 5 in. 3 1.61 in.(59mm) -� (188mm) `r"('�,ej 5.5 in. (127mm) 1 1 +,P^ (140mm) ri)it (41mm) y SPACER I 2 in. .78 in. 1 (simm) 6.x1 in. (zOmm) 2"DEPtrly(somm) i 1� F (173mm) SIDE VIEW MODELS WITHOUT HORN(STI-3150 Series) ALL MODELS END VIEW EXTERNAL DIMENSIONS: •Flush 7.2 W x 10.2 H x 3.3 Din. (183x259x84mm) •Surface 7.2 W x 10.2 H x 5.5 Din.(183x259x140mm) ® 2306 Airport Road Tel:248-673-9898 Taylor House 3 Tel:+44(0)1527 520 999 Safety Technology Waterford,Michigan Fax:248-673-1246 Sherwood Road Fax:+44(0(1527 501 999 International 48327,USA Toll-free:800-888-4784 Bromsgrove,Worcestershire info@sti-emea.com infc@sti-usa.com 660 3DR,England www.sti-emea.com www.sti-usa.com Printed in U.S.A.,a 1987-2017 Safety Technology International,Inc. Subject to change without notice. 07/18 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1/4-inch back box,4 x 4 x 1 Y-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 11/2-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also, L-Series products,when used with the Sync•Circuit.m Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 4"71e x 21/a-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. • Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate • 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91-D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions- 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05•2/22/2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal P Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 'Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVDSS€5-05•2/22/2015•Page 3 L-Series Dimensions I, as mm Be mmL25' 7.5T— Lam' 88 rnm IO of .__1.75" r -t-- -. . 7P mm 34 mm (9.1 cm) (2S cm) ' o6jzo q `P n ° °c° ° °cO�B o 74+ o ted _TT 11111 I S,77• •°o°°°°°°°or 4°°° a• l 6A1 O C 1339 rem °°° °,°° °°°°° g U . A0548.00 A0547 00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL (11.94 cm) --- 1.91" • 119 mm - 1R5" _. 4M. 32 mm (ta34 and -"'.. -1,85' ROB cm) 77 5 (3.18 mm) k ' 1 �.® 0 1 �_jJ (144cm) 1m 14, m) -- ` _ Strobe,Horn Strobe Rosso no 40543 00 A0554-01 Horn Wall Surface Mount Back Box SBBRLJSBBWL L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns* P2RL 2-Wire,Horn Strobe,Red - HRL* Horn,Red P2WL 2-Wire,Horn Strobe,White HWL' Horn,White I P2GRL 2-Wire,Compact Horn Strobe, Red HGRL* Compact Horn,Red P2GWL 2-Wire,Comp 2 fils act Horn Strobe,White HGWL* Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire, Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box. Red P4RL 4-Wire, Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White SBBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe,Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red, FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. All-ALERT models have"ALERT'marking on cover. 'Horn-only models are listed for wall or ceiling use. SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 820,8 System Sensor �$ SENSOR Phone:800-SENSOR2•Fax:630-377-6495 Product specitieatons subject kr change wicnoulnotice.visits7stemsensurcurn for current product Intormaton,including the latest version of thin data shed.Www.systemsenS000Om AVn5665-05.2/22/2018 SYSTEM ._4111 SENSOR It r,r ;ri '.IIIIIIIIIIIl II,I:' I;,I � : rllttiltrilir, ,l,l l,l, tlt l l l t l l l l l l r,rl Indoor Selectable- ,1,r 1,1, 1, i, Out I,rI4i41 f • r'r' put Speaker Strobes and Dual -- Voltage Evacuation Speakers for Wall Applications System Sensor L-Series selectable output speaker strobes and dual-voltage evacuation speakers can reduce ground • faults and enable faster installation with lower current draw and modern aesthetics. The System Sensor L•Series of speakers and speaker strobes Features reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, • Plug-in design and protective cover reduce ground faults dress the wires,and confirm wiring continuity before plugging in the • Universal mounting plate with an onboard shorting spring tests speakers. In addition,a protective plastic cover prevents nicked wiring continuity before installation wires by covering exposed speaker components. • No extension ring required These devices also enable faster installations by providing instant • Field selectable candela settings on wall units: feedback to ensure that wiring is properly connected, rotary switches 15,30,75,95, 110, 135, 185 to select voltage and power settings,and 7 field-selectable candela • Automatic selection of 12-or 24-volt operation settings for wall speaker strobes. at 15 and 30 candela The low total harmonic distortion elity • Rotary switch simplifies field selection of speaker voltage sound output while still offering high volume soundhigh output ford use (25 and 70.7 Vrms)and power settings(1/4, Y, 1 and 2 watts) in high ambient noise applications. • Speakers offer high fidelity and high volume sound output • 520 Hz+/- 10%square wave tone capable with compatible FACP System Sensor L-Series makes installation easy •Attach • Compatible with System Sensor synchronization protocol Flushmountvappl cations do note require an extension rick box. • Electrical compatibility with existing SpectrAlert and SpectrAlert •Connect the notification appliance circuit or speaker wiring to the Advance products terminals on the mounting plate. • Tamper-resistant construction •Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge • Updated modern aesthetics the device into position to lock the product pins into the mounting plate terminals.The device will temporarily hold in place with a Agency Listings catch until it is secured with a captured mounting screw. SIGNALING �T ® C LISTED nrrnovep [ S4048 FM approved except 7320'16530505 for ALERT models 3057493 AV1S867-02•03/23/2018•Page I L-Series Speaker and Speaker Strobe Specifications General L-Series speaker and speaker strobes shall mount to a 4 x 4 x 2118-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate.Also,L-Series speaker strobes,when used with the Sync•Circuit""Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC,or full-wave rectified,unfiltered power supply.Wall- mount speaker strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135, 185. Speaker The speaker shall be aSp System Sensor L-Series model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service.The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F.The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems.The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch,and shall have a frequency range of 400 to 4,000 Hz.The speaker shall have power taps that are selected by rotary switch.The strobe shall comply with the NFPA 72 requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize strobes at 1 Hz.The module shall mount to a 411/1s x 411/16 x 21/e-inch back box.The module shall also control two Style Y (class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Dimensions,Wall-Mount Length Width Depth SPL Speaker 6.5 in, 165 mm 5 in, 127 mm 0,97 in,23 mm With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 3.2 in.82 mm SPSL Speaker/Strobe 6.5 in, 165 mm 5.0 in, 127 mm 2.3 in,58 mm (including lens and speaker) With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 4.5 in, 116 mm 'When using 12AWG, 14 AWG,or adding extra wires in the box,a deeper box or extension ring is recommended. Electrical/Operating Specifications Nominal Voltage(speakers) 25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage(speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage(strobes) Regulated 12 VDC or regulated 24 DC/FWR12 Operating Voltage Range(includes fire 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) alarm panels with built in sync) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16 5 to 33 V(24 V nominal) Frequency Range 400 to 4000 Hz3 Power 1/4,1/2, 1,2 watts 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 and 30 cd 3.520 Hz+1- 10%square wave tone capable with compatible FACP. AVDS867-02.03/23/2C18•Page 2 UL Current Draw Data UL Max Strobe Current Draw(mA RMS) 8 to 17.5 Volts 16 to 33 Volts Candela DC DC FWR 15 88 43 60 30 143 63 83 75 - N/A 107 136 95 N/A 121 155 110 _ N/A 148 179 135 N/A 172 209 185 N/A 222 257 Sound Output Speaker Strobe 1/aw 1/2W 1W 2W UL Reverberant(dBA 010 ft) 77 80 83 86 UL Anechoic(dBA o10 ft) 77 80 83 86 Sound Output Speaker YaW 12W 1 W 2W UL Reverberant(dBA 010 ft) 79 82 85 88 1 UL Anechoic(dBA©10 ft) 79 82 85 88 L-Series Dimensions 0.97" - > - E— 1.63" 5 _—_.. (24.69 mm) (41.66 mm) 23 - _. 1.63" (127 mm) 5„ (56 mm) �'I (41.66 mm) ' (121r mm) 35.31 mm) — 139 �inBe�O°Po°°0eea�1�� go/ 1 : 1 °u° I pe °°�Ooo°uo°e°°4 P __ + { ail 6.5• S ,Xe°°°°°q°,°°°°°e°°° 60 65 uuuuuv (165') °o A°v°oOPO °°a °Ou a II 165 mm) [i °� I I111r �I� I.._ �I g°' °°ova°°°e°°°°°° ° {' III 40855.01 i Nisi rrr���"e'dommw `! AG556-01 Wall-Mount Speaker Wall-Mount Speaker Strobe AVD5861-02•03123/2018•Page 3 • Surface Mounting /T _ � ®n l �/� — • A°A°"AAA A 1 ,� `� , 1 I I�r(���� � ( OOO BAAAAAA AAABAB9BAA.A.A6BA°"I t' �'OJOA A/�-.qq�B ABBBOASP.��4 ,„ t ®®B � PBBPOBPBBAA4B'i ,4: v A®® ItAO,,,„ A610An5A•i �_ 1m BABA: ®400�a an%;Bd ,„ ii, B °I o BOB °' BOB: -�rg�� i :i:iti' y°iri°i.iinh r° ° Aed23-01 Wall-Mount Speaker Strobe with SBBSPRL/SBBSPWL Surface Mount Back Box L-Series Ordering Information Wall Mount White Red Description SPWL SPRL Speaker only SPSWL SPSRL Speaker Strobe SPSWL-P SPSRL-P Plain Speaker Strobe SPSWL-ALERT — Speaker Strobe,Amber Lens SPSWL-CLR-ALERT — Speaker Strobe Clear Lens — SPSRL-SP Speaker Strobe,Fuego Accessories White Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SBBSPWL SBBSPRL Surface Mount Back Box for Speakers and Speaker Strobes TR-2W TR-2 Wall Mount Trim Ring Notes: All-P models have a plain housing(no 'FIRE"marking on the cover) f���� SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ®zo,e System se r SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 PIad,Ot0pniritatpn0 subject t0 adage without,,aee Vaits�emseaso,com tot current product Information,including the Ia:ost version of this data sheet. www.systemsensor.com AVDS867-02.0323/2018 amassam HORN /STROBE/SPEAKER DAMAGE STOPPERS ® ilk . ., . .., , . 4 ..,,,, .e'F'f t x.f j >. t bg v iii eilloweimill 1f �: ' r "ur l si AWNS STI-9705-R STI-9711 11111110 l III '4 ' ll KEY FEATURES - li _ General Information 4...41ewV „. ti �' �=. . ' •Offers protection against vandalism STI-9720 and accidental damage. •Simple removal for maintenance. •Three year guarantee against breakage in normal use. PRODUCT OVERVIEW Construction Here are excellent ways to protect strobe units against both vandalism and accidental • Constructed of tough 9-gauge steel wire. damage. Constructed of tough, 9-gauge steel wire coated with corrosion resistant red Coated with corrosion resistant or white polyester, these guards can take hard knocks in stride. STI-9705, STI-9708, polyester. STI-9711 and STI-9714 wire guards provide maximum protection for System Sensor Installation SpectrAlert®Advance series strobe notification appliances. -Installation is fast and simple with screws and anchors provided. BACKED BY A THREE YEAR GUARANTEE Options As all STI protective covers, these guards are backed by a three year guarantee against • STI-9705,STI-9708,STI-9711 and STI-9714 protect SpectrAlerta breakage in normal use. Installation and servicing is easy with all screws and anchors strobe units. provided. This Stopper is highly recommended for areas where abuse is severe or it is • STI-9717 and STI-9720 fit over imperative that strobe units continue to operate. STI-9717 and STI-9720 fit over System System Sensor notification appliances P2R1224MC and Sensor notification appliances SP2R1224MC and SP2W1224MC. SP2W1224MC. For more information,call 1-800-888-4784(4STp or visit www.sli-usa.com • ® Safety Technology International Horn/Strobe/Speaker Damage Stoppers° Dimensions and Technical Information MODELS AVAILABLE APPROVALS & WARRANTY STI-9705 Damage Stopper,Flush Mount-White TESTING ---> STI-9705-R Damage Stopper,Flush Mount-Red STI-9708 Damage Stopper,Surface Mount-White STI-9705,STI-9708,STI-9711 and STI-9714 have been tested and STI-9708-R Damage Stopper,Surface Mount-Red approved or listed by: STI-9711 Damage Stopper, Flush Mount-White Underwriter Laboratories and Canadian UL File S7025 STI-9714 Damage Stopper,Surface Mount-White WARRANTY STI-9717 Speaker/Strobe Damage Stopper-Flush Mount Three year guarantee against breakage in normal use, . (not UL Listed) STI-9720 Speaker/Strobe Damage Stopper-Surface Mount Light De-Rating Factor Light Loss (not UL Listed) STI-9705 and STI-9708 % System Sensor(SR,SW, SW-ALERT, SW-CLR-ALERT, SRK, 13% MODEL HEIGHT WIDTH DEPTH SWK, P2R, P2W, P4R, P4W, CHSR, CHSW, P2RK, P2WK, STI-9705 P4RK, P4WK, SPSR, SPSR-SP, SPSR-PG, SPSW, SPSW- STI 9705-R 740 in.(188mm) 6.t5 in (156mm) 3.39 mm CLR-ALERT, SPSW-SP, SPSW-PG, SPSRV, SPSRV-SP, In (84 ) SPSRV-PG,SPSWV, SPSWV-SP and SPSWV-PG, SPSWK, STI-9708 SPSRK,SPSW-ALERT) STI-9708-R 7.49 in. (190mm) 6_74 in.(171mm) 6.09 in.(155mm) System Sensor (SRH, SWH, SRHK, SWH-ALERT, SWHK, 0% STI-9711 8.26 in.(210mm) 8.26 in.(210mm) 3.54 in.(90mm) P2RH,P2WH, P4RH, P2RHK,P2WHK,P2RHK-120,SPSRH, SPSRH-SP, SPSRH-PG, SPSWH,SPSWH-SP and SPSWH- STI-9714 8.55 in.(271mm) 8.55 in.(271mm) 6.23 in.(158mm) PG,SPSRHK) STI-9717 Si in.(155mm) 9.3 in.(238mm) 2.4 in.(61mm) STI-9711 and STI-9714 STI-9720 6.1 in.(155mm) 9.3 in.(238mm) 4.9 in.(125mm) System Sensor (SCR, SCW, SCRK, SCWK, SCW-CLR- 0% __ ALERT, PC2R, PC2W, PC4R, PC4W, PC2RK, PC2WK, I■I■I�r �h �, PC4WK, SPSCWV, SPSCR, SPSCR-SP, SPSCR-PG, I SPSCW, SPSCW-SP, SPSCW-PG, SPSCWV, SPSCRV- I1I11■ 1111I BIM I PG, SPSCWV, SPSCWV-SP and SPSCWV-PG, SPSCWK, SPSCW-CLR-ALERT) 11111 I1I1I I�I�I(188mm) SPC2WH PC4RHstem Sensor �PC2RHK,PC2WHK,PC4WHK,SPSCWHVSCRH, SCWH, SCRHK, SCWHK, , 0% I11I111 J1I1i l,I�ImI SPSCRH, SPSCRH-SP, SPSCRH-PG, SPSCWH, SPSCWH- �l`IN �I J �'I.I SPSCWHV-SP SPSCWHV PG,SPSCWHK)SPSCRVH-SP,SPSCRVH-PG, 6.15 in. 3.39 in.. I (156mm) (86mm) STI-9705 3.7 in. 3.15 in. 1.63 in. (94mm) (80mm) (41mm) I� H 1.9 in. _ (125mm) Will L111 I 'I�I�• I STI-9720 3.1 in. 1 7.49 in. TOP VIEW (79mm) IIIII I■IiI (190mm) MIME IN pi" 11�ImI■I II II IIII u u III 31 in. `�MO I \ t (61mm) ` �I STI-9717 6.74 in. 6.09 in. TOP VIEW (171mm) (155mm) 9.3 in.(238mm) STI-9708 _ a cl/III�..."\ ''`,. .4(-^ i I�_— 01 �i/ 111_ •11.I.I,I,1.11..1. 6.t in. '_"I ll 1 I AI'.I I�1 ■.... (155mm) �/ 2i0 in. 8.55 in. "" til i ����itV��//(.�i �,�I(210mm) �,I,�(271mm) 11...I, [.'� �'�' 2.5° 3.54 in.(90mm)� t 6.23 in._� (158mm) STI-9717 and STI-9720 STI-9717 STI-9711 FRONT VIEW SIDE VIEW 4111 SafetyTechnology2306 Airport Road Tel:248-673-9898 Taylor House Tel:+44(0)1527 520 999 Waterford,Michigan Fax:248-673-1246 34 Sherwood Road Fax:+44(0)1527 501 999 International 48327,USA Toll-free:800-888-4784 Bromsgrove,Worcestershire info@sti-emea.com info@sti-usa.com 860 3DR,England www.sti-emea.com www.sti-usa.com Printed in U.S.A.,C 1987-2017 Safety Technology International.Inc. Subject to change without notice. 08/15 Th SYSTEM �$ SENSOR Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Ceiling Applications System Sensor L-Series selectable-output speaker strobes aft and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal Features mounting plate that allow the installer to pre-wire mounting plates, • Plug-in design and protective cover reduce ground faults dress the wires, and confirm wiring continuity before plugging in the speakers. In addition,a protective plastic cover prevents nicked • Universal mounting plate with an onboard shorting spring tests wires by covering exposed speaker components. wiring continuity before installation • No extension ring required These devices also enable faster installations by providing instant • Field selectable candela settings on ceiling units: feedback to ensure that wiring is properly connected, rotary switches 15,30,75,95, 115, 150,and 177 to select voltage and power settings,and 7 field-selectable candela settings for both wall and ceiling speaker strobes. • Automatic selection of 12-or 24-volt operation at 15 and 30 candela The low total harmonic distortion of the SP speaker offers high fidelity • Rotary switch simplifies field selection of speaker voltage(25 sound output while still offering high volume sound output for use in and 70.7 Vrms)and power settings('/A,'/2, 1 and 2 watts) high ambient noise applications. • Speakers offer high fidelity and high volume sound output L-Series makes installation easy • 520 Hz+/-10%square wave tone capable with compatible FACP •Attach a universal mounting plate to a 4 x 4 x 2'/s inch back box. • Compatible with System Sensor synchronization protocol Flush-mount applications do not require an extension ring. • Electrical compatibility with existing SpectrAlert and SpectrAlert •Connect the notification appliance circuit or speaker wiring to the Advance products terminals on the mounting plate. •Attach the speaker or speaker strobe to the mounting plate by • Tamper-resistant construction inserting the product tabs into the mounting plate grooves.Hinge • Updated modern aesthetics the device into position to lock the product pins into the mounting plate terminals.The device will temporarily hold in place with a Agency Listings catch until it is secured with a captured mounting screw. SIGNALING ( LISTED APPROVED L 7 54048 FM approved except 7320-1653:0505 to ALERT models 3057493 AV05860-03.03123/2018•Page 1 L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General L-Series speaker and speaker strobes shall mount to a 4 x 4 x 21/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate.Also, L-Series • speaker strobes,when used with the Sync•CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC,or full-wave rectified,unfiltered power supply.Speaker strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150, 177. Speaker - The speaker shall be a System Sensor L-Series model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service.The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F.The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems.The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch,and shall have a frequency range of 400 to 4,000 Hz.The speaker shall have power taps that are selected by rotary switch.The strobe shall comply with the NFPA 72 requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz.The module shall mount to a 411/1s x 411/16 x 2'/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Dimensions,Ceiling-Mount Diameter Depth SPC Speaker 6.8 in, 173 mm • 1.0 in,25 mm With Surface Mount Back Box 6.9 in, 176 mm 3.5 in,89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in,73 mm With Surface Mount Back Box 6.9 in, 176 mm 5.37 in, 136 mm *When using 12AWG, 14 AWG,or adding extra wires in the box,a deeper box or extension ring is recommended. Electrical/Operating Specifications Nominal Voltage(speakers) 25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage(speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage(strobes) Regulated 12 VDC or regulated 24 VDC/FWR 1'2 Operating Voltage Range(includes fire 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) alarm panels with built in sync) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Frequency Range 400 to 4,000 Hz3 Power Y4,'/2 1,2 watts 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 and 30 cd. 3.520 Hz+/-10%square wave tone capable with compatible FACP. AVDS866-03•03/23/2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8 to 17.5 Volts 16 to 33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 NA 111 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 Ceiling-Mount Speaker Sound Output Setting UL Reverberant(dBA 410 ft) UL Anechoic(dBA 410 ft) 1/4 W 79 79 1/2 W 82 82 1 W 85 85 2 W 88 88 Ceiling-Mount Speaker Strobe Sound Output Setting UL Reverberant(dBA 410 ft) UL Anechoic(dBA 410 ft) 1/4 W 77 77 1/2 W 80 80 1 W 83 83 2 W 86 86 L-Series Dimensions 88'05. 1.8• 1.63• m. On mm) (SA mm) (41.66 mm) c_v1;P_ •r` L/)�M1 k AB x -4Z&�� M1r11 % II I� :II) Iti( 1fll 11III(gllffl L b ! 4j Ai111NI'.j,�IffiI�ill-0 . 17 ( lef �� S'Sy,6�lHl - i �r rr— Aoan3 ou Ceiling Speaker z9 8.8'dc Q1� mm) 688• r (173 mm) 161.66 mm) (N.7 mm) 47malMNI a Ya i a is9 a;a 47:4. K •tf�VV�..`VI' it ®Y A054n-X Ceiling Speaker Strobe AVDS866-03•033123/201b•Fage 3 Surface Mounting -4s /, ---- - - r_ ii„; ,--...6 , "Ei r � �F �(yt- ii...N 11 ip 1,, ____ yti, h N. ZZ3i"lil. 1 :1�'a1 # ty� PN+i 0/75.772.1.51t,rXts, al >}11 Ceiling Speaker with Surface Mount Back Box Ceiling Speaker Strobe with Surface Mount Back Box ice\ �a oOo 9 o 0 ol i o V *� i Au5.2 0U Ceiling Speaker Strobe with Trim Ring and 4"Square Electrical Box L-Series Ordering Information Ceiling Mount White Red Description SPCWL SPCRL Speaker only SPSCWL SPSCRL Speaker Strobe SPSCWL-P Plain,Speaker Strobe SPSCWL-SP Fuego,Speaker Strobe SPSCWL-CLR-ALERT Alert,Speaker Strobe,Clear Lens Accessories White Red Description SBBCWL SBBCRL Universal Ceiling Surface Mount Back Box TRC-2W TRC-2 Universal Ceiling Trim Ring *� SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ®2o19 System Sensor Phone:800-SENSOR2•Fax 630-377-6495 Product specifications subject change without notice visit systerrsensorcan SENSOR for current product information.includirg tie latest versior of tits data sheet. www.systemsensor.Com AVDS866-03.03t2,l20te SYSTEM --- *Th_, SENSOR `.F i Ir e Outdoor, Selectable- F r l p . Output Speaker t • tl Strobes and Dual- !° `-: ` R ' Voltage Evacuation Speakers for Wall SPECTRAlert Applications air any AG. PAC % SpectrAlert°Advance outdoor, selectable-output speaker strobes and dual-voltage evacuation speakers meet SpectrAlert Advance offers the broadest line of outdoor speakers and speaker strobes in the industry.From metal and plastic virtually any outdoor application requirement. outdoor back boxes, to white and red plastic housings,to wall and ceiling mounting options, SpectrAlert Advance can meet virtually any application requirement. Features • Weatherproof per NEMA 4X, IP56 Wall-mount outdoor speakers and speaker strobes can be used indoors or outdoors in wet or dry applications.and can provide • Rated from -40°F to 151°F reliable operation from—40°F to 151°F.These speakers provide • Plug-in design reduces ground faults a broad frequency response range, low harmonic distortion and • Universal mounting plate with onboard shorting spring that tests maintain a high sound pressure level at all tap settings to provide wiring continuity before devices are installed accurate and intelligible broadcast of evacuation messages. • Field-selectable candela settings: 15, 15/75,30, 75.95, 110, 115, Like the entire SpectrAlert Advance line,wall-mount outdoor speakers 135, 150, 177,and 185 and speaker strobes include a variety of features that increase • Automatic selection of 12-or 24-volt operation at 15 and application flexibility and simplify installation. First,field-selectable 15/75 candela settings, including candela,speaker voltage and power settings,and • Rotary switch for speaker voltage(25 and 70.7 Vrms)and power automatic selection of 12-or 24-volt operation enable installers to settings(1/4, 1/2, 1 and 2 watts) easily adapt devices to meet requirements. • Compatible with System Sensor synchronization protocol and Next,these devices use a universal mounting plate with an onboard legacy SpectrAlert products shorting spring that ensures wiring continuity before devices are • Tamper-resistant construction installed,so installers can verify proper wiring without mounting the • Listed for ceiling or wall mounting devices and exposing them to potential construction damage. Once the plates are mounted,all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater Agency Listings corrosion.Knock-outs located on the back eliminate the need to drill SIGNALING holes for screw-in mounting.Plastic and metal weatherproof back 0 MEA boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch LISTED approved knock-outs at the back.A screw-in NPT plug with an 0-ring gasket s 7320-65320' 1)r,3-1- for a watertight seal is included with each back box. SpectrAlert®Advance Outdoor Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General SpectrAlert Advance outdoor speakers and speaker strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance speaker strobes,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40°F and 151°F from a regulated DC,or full-wave rectified,unfiltered power supply. Speaker Speaker shall be a System Sensor SpectrAlert Advance Model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms.Speaker shall be listed to Underwriters Laboratories Standard S4048 for outdoor fire protective signaling systems.Speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature from-40°F to 150.8°F.Speaker shall have power taps,and wattage settings that are selected by rotary switches.The speaker must be installed with its weatherproof back box in order to remain outdoor approved per UL listing S4048.The speaker shall be suitable for use in air handling spaces and wet environments, Speaker Strobe Combination The speaker strobe shall be a System Sensor Model listed to UL 1638 and UL 1480 and be approved for fire protective signaling systems.Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms and shall have a frequency range of 400 to 4,000 Hz.Speaker shall have power taps that are selected by rotary switch.The strobe shall consist of a xenon flash tube with associated lens/reflector system and operate on either 12 or 24 volts.The strobe shall also feature selectable candela output,providing options for 15 or 15/75 candela when operating on 12 volts and 15, 15/75,30,75, 110, 115, 135, 150, 177 or 185 candela when operating on 24 volts.The strobe shall comply with the Americans with Disabilities Ad requirement for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The speaker strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The speaker strobe shall be suitable for use in wet environments. Physical Specifications Operating Temperature -40°F to 151°F(-40°C to 66°C) Dimensions,Wall-Mount SPS Speaker Strobe P 6.0"L x 5.0"W x 4.7"D(including lens and speaker) SP Speaker 6.0"L x 5.0"W x 2.9"D Dimensions,Wall-Mount Weatherproof Back Box 6.5"L x 5.5"H x 2.9"D Electrical/Operating Specifications Nominal Voltage(speakers) 25 V or 70.7 V(nominal) Maximum Supervisory Voltage(speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage(strobes) Regulated 12 VDC/FWR or regulated 24 DC/FWR Operating Voltage Range(includes fire alarm 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) panels with built in sync) Operating Voltage with MDL3 Sync Module 8,5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Frequency Range 400 to 4,000 Hz Power Ya,Yz, 1,2 watts AVDS113C1 UL Current Draw Data Candela Derating UL Max.Strobe Current Draw(mA RMS) For K series products used at low 8 to 17.5 Volts 16 to 33 Volts temperatures, listed candela ratings must be Candela DC FWR DC FWR reduced in accordance with this table. Standard 15 123 128 66 71 Strobe Output(cd) Candela Range 15/75 142 148 77 81 Candela rating at Listed Candela -40°F 30 NA NA 94 96 75 NA NA 158 153 15 95 NA NA 81 176 15/75 Do not use below 32°F 110 NA NA 202 195 30 115 NA NA 210 205 75 44 High 135 NA NA 228 207 95 70 Candela Range 150 NA NA 246 220 110 110 177 NA NA 281 251 115 115 185 NA NA 286 258 135 135 Sound Output 150 150 UL Reverberant(dBA © 10 ft.) 2W 1W 1 W Y4 W 177 177 Outdoor Speaker 90 87 84 81 185 185 Outdoor Speaker/Strobe 89 86 83 80 Dimensions 97H-1.84"" 5.00" 2.83"" 5.00"" 1.604_ _-- 1.84� t1■k r • 1111111 .11 5.98` � 1 5.97` -- +I - Wall-Mount Outdoor Speaker Wall-Mount Outdoor Speaker Strobe AVDS11301 Surface Mounting .' i'k.:_., .il10iu,4,,,, l.im-0 y t,.�:, . q :III Wall-Mount Speaker Strobe with Plastic Weatherproof Back Box Wall-Mount Speaker with Plastic Weatherproof Back Box ,A >' i��^ III 7' IIN it C. ) • to 2 N „,,ii-,,,,,,,__-, -0 (all•° I � �» ++(�0 ) ,rsti�!� L ;0. 1� . ,,,1��: in aI Wall-Mount Speaker Strobe with Metal Weatherproof Back Box Wall-Mount Speaker with Metal Weatherproof Back Box Ordering Information for SpectrAlert®Advance Outdoor Speakers and Speaker Strobes Wall Mount White Red Description SPWK SPRK Outdoor Speaker(includes plastic weatherproof back box) SPWK-R SPRK-R Outdoor Speaker(does not include plastic weatherproof back box) SPSWK SPSRK Outdoor Speaker Strobe,Standard cd(includes plastic weatherproof back box) SPSWK-P SPSRK-P Plain Outdoor Speaker Strobe,Standard cd(includes plastic weatherproof back box) SPSWK-R SPSRK-R Outdoor Speaker Strobe,Standard cd(does not include weatherproof back box) SPSWK-CLR-ALERT Outdoor Speaker Strobe,Standard cd,Clear Lens,ALERT Printed (includes plastic weatherproof back box) SPSRHK Outdoor Speaker Strobe,High cd(135,150,177,185)(includes plastic weatherproof back box) Accessories White Red Description MWBBW MWBB Wall, Metal Weatherproof Back Box Notes: All-P models have a plain housing(no"FIRE"marking on cover) "Standard cd"refers to strobes that include 15, 15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135, 150, 177,and 165 candela settings.When replacing standard outdoor units,both the device and back box must be replaced. i� SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications 012 System s emSntr.r subject to t;e6Visit 5Y51em y ,CP ._earr.V SENSOR' Phone:800-SENSOR?•Fax 630-377-6495 tor current productnformation,including the latest version of this data sheet. AVM 1301•09/12 5®SimplEx Fire Alarm System Accessories UL, ULC, CSFM Listed; RSG Electromagnetic Door Holders; FM Approved* Wall Mounted or Floor Mounted Features Product Reference Images Electromagnetic door holders from RSG (Reliable (shown without screw hole caps in place) Security Group)with four mounting types: • Semi-flush wall mount for shallow box applications • Surface wall mount with matching box ,~ • Flush wall mount with recessed magnet for low profile applications • Floor mount, for single or double doors Multiple finish options: • High luster plating of chrome,brass,or dark bronze • Powdercoated in chrome or dark bronze Low current, multi-voltage design reduces power supply and battery demands: • Models are available for operation with 24 VDC, 24 VAC,or 120 VAC Semi-Flush Wall Mount Door Holder Magnet • Internal full wave rectifier allows AC or DC operation and Catch Plate Assembly and provides switching transient suppression • Low residual magnetism allows easy door release for compatibility with low pressure door closers • Rated holding force ranges from 20 lbs(9 kg) minimum;to up to 110 lbs(49.8 kg) Quick and easy installation: • Self-adjusting swivel catch plate adjusts to door alignment changes • Adhesive mounting templates assure alignment • Required mounting hardware is supplied with each ,. door holder • Magnet catch plates can be screwed to wooden doors or drilled through and attached to a mounting bracket Surface Wall Mount Door Holder Magnet • Floor mount door holders include drills and anchors with Supplied Box for mounting to concrete floors and hardware for mounting to wooden floors • Front plates provide convenient grounding screw location Optional accessories: • Extension rods are available in multiple lengths to *e - allow proper alignment,including a 4"(102 min)long pivoting rod • Drilling fixture for accurate repetitive installation UL listed to Standard 228 Descri•tion Floor Mount Door Holder Magnet with Supplied Bracket and Box Door holders are normally energized to magnetically hold (Single door model shown, available for double doors) doors open. In the event of a fire emergency,the fire * These products have been approved by the California State Fire Marshal(CSFM) alarm control panel or other compatible control means pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing will release the magnet allowing the door to close to 3550-1039.0100 for allowable values and/or conditions concerning matenal presented in manuallythis document.It is subject to re-examination,revision,and possible cancellation prevent the spread of smoke.Doors ma . y be Additional listings may be applicable,contact your local Simplex®product supplier far the closed or opened when the door holder is energized. latest status.Listings and approvals are under RSG,Reliable Security Group. S2088-0014-2 8/2012 Product Selection (see specifications on page 4 and part number selection below) Mounting Type Hardware Included Electrical Box Requirement Semi-flush Mount Magnet assembly, catch plate with bracket, screw hole Single gang box, 1 ''/2"deep (partially recessed magnet) caps, and required mounting hardware minimum (supplied separately) Flush Mount Magnet assembly, catch plate with bracket, screw hole caps,and required mounting hardware(not shown on Single gang box,2 '/,"deep (fully recessed magnet) minimum(supplied separately) page 1, refer to illustration on page 3) Magnet assembly, catch plate with bracket, screw hole Surface Mount caps, matching electrical box, and required mounting hardware Floor(ground)Mount for Magnet assembly with electrical box,catch plate with single door with single bracket,floor mounting bracket, screw hole caps, and Box is supplied with door holder: magnet required mounting hardware including drills and anchors for 4'/,"H x 23/4"W x 1 1/2" D concrete floors (117 mm x 70 mm x 54 mm) Floor(ground)Mount for Two surface mount magnet assemblies with electrical box, double door with double each with electrical box;two catch plates with brackets, magnets screw hole caps,and required mounting hardware including drills and anchors for concrete floors Optional Door Holder Accessories Model Powdercoat Brass Description Chrome DHE1PC DHE1B Catch plate extender rod, 1"(25.4 mm)long DHEI.5PC DHE1.5B Catch plate extender rod, 1 %"(38 mm)long Each extender DHE2PC DHE2B Catch plate extender rod, 2" (51 mm)long rod includes two DHE3PC DHE3B Catch plate extender rod, 3"(76 mm)long DHW extension wrenches DHE4APC DHE4AB Catch plate with adjustable extender rod,4"(102 mm) long with center pivot Model Description DHDF Drilling Fixture, provides convenient alignment for repetitive installation DHW Extension Wrench for adding extender rod to catch plate(two are needed,two are shipped with each extension) Door Holder Part Number Selection Select from each of the 6 categories to create part number(see examples below) 1 2 3 4 5 6 Door Holder Operating Voltages Mounting Style Finish Type Finish Color Floor Mount Coils Select Select For Select For Select For Select For Select For 12 VDC S Surface 1224 12 VAC — Mount 24 VDC P Powdercoated C Chrome Single 24 VAC F Semi-Flush 1door Mount Floor 24120 24 VAC G (Ground) B Brass 2 Ddoore DH 24 VDC 120 VAC Mount blank High luster 24 VDC Flush Mount plated R (Recessed DBR Dark blank Not floor 24220 24 VAC Magnet) Bronze mounted 220 VAC Examples: 1.DH2412ORPC: Door holder;24 VDCNAC, or 120 VAC operation; Recessed magnet/flush mount; Powdercoated; Chrome finish 2. DH24120GB2: Door holder;24 VDCNAC,or 120 VAC operation; Ground/floor mount; Brass finish,high luster; Double door 3.DH1224SPC: Door holder; 12 or 24 VDCNAC operation;Surface mount;Powdercoated;Chrome finish 2 S2088-0014-2 8/2012 Semi-Flush and Surface Mount Dimensions 15/16" 15/16" 1-1/8" (24 mm) 1-1/2" 2-3/4" (24 mm)1 (29 mm) (38 i m)� �(70 mm)-1 'I�' I �II 2-7/16" (62 mm) l 3 5116" 4-5/8" L 84 mm 43/4" 4" ( ) (117mm) (121 mm) m) 0 / Surface Mount End View (mount vertically or Semi-Flush and Surface Semi-Flush Surface Mount Side View horizontally as needed) Mount Front View Side View (conduit entries are provided on ends and back of box) J Flush and Floor Mount Dimensions 3" �(76 mm)� 1.4_1-13/16" (46 mm) A I 4" / _ (102 mm) '''''''' ..,: 3-5/16" / 4-3/4" (84 mm) (121 mm) .__p ; Op ' Single Door 3"(76 mm) Double Door • 5-7/16"(138 mm) Flush Mount Front View Flush Mount Side View Floor Mount Side View J 3 S2088-0014-2 8/2012 Catch Plate and Mounting Bracket Dimensions 1...._2-3/16" Catch Plate (56 mm) � Catch Plate Mounting Bracket 1 2-3/8" 3/16" 1-3m " Screw holes 2 1' (60 mm) 5 mm 44mmIII-to1-3/4" �� ( ) 1 ) (44 mm) /4" (57 mm) 7/8" _� I (22 mm) I' 'I' 1-3/4" H Magnet side Door side (44 mm) I a Ball swivel 3/4" Threaded rod (19 mm) extensions insert here J Specifications Mechanical Specifications Material Durable die-cast metal Wiring Connections Three position terminal block with provisions for in/out wiring;common (C), low voltage, high voltage);22 to 12 AWG(0.5 to 3.31 mm2) Electrical Specifications and Performance Model Voltage Current DC Current AC Terminals Holding 1224 12 V 40 mA 38 mA C&L 24 V 40 mA 36 mA C&H 30 lbs(13.6 kg) 1224 High Holding Force 24 V 85 mA 81 mA C &L 75 lbs(34 kg) 24120 24 V 20 mA 19 mA C& L 40 lbs(18.1 kg) . 120 VAC — 20 mA C&H 35 lbs (15.8 kg) 24120 High Holding Force 120 VAC — 100 mA C&L 110 lbs(49.8 kg) 24220 24 V 20 mA 19 mA C&L 20 lbs(9 kg) 220 VAC - 15 mA C&H 22 lbs(9.8 kg) For additional information, visit the RSG website: http://www.rsgsecuritv.corn! TYCO,SIMPLEX and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited. ftSi m p I Ex Tyco Fire Protection Products• Westminster,MA• 01441-0001•USA S2088-0014-2 8/2012 www.simplexgrinnell.corn ©2012 Tyco Fire Protection Products.All rights reserved All spec fcahans and other information shown were current as of document revision date and are subject to change without notice.