Loading...
Report OFFICE COPYNiii RECEIVED ='= 'ilPAE • JUN 1 5 2021 • June 3, 2021 CITY OF TIGARD BUILDING DIVISION Beth Cantrell DECA Architecture Inc. 935 SE Alder Street Portland, OR 97214 Project: TTSD Templeton Pre-K Conference Center Project Number: 20-1107 Subject: Submittal Review Dear Beth: Fire Alarm submittal 28 30 00-01 received May 12, 2021 has been reviewed by this office with the following disposition: Item Manufacturer Action 283000 FIRE DETECTION AND ALARM Fire Alarm Control Panel Honeywell No Exceptions Taken Amplifier Honeywell No Exceptions Taken Communication System • DSC No Exceptions Taken Power Module Honeywell No Exceptions Taken Operator Console Honeywell No Exceptions Taken Smoke Detectors Honeywell No Exceptions Taken Mounting Base System Sensor No Exceptions Taken Damage Stoppers (Wire Guard) STI, Chase No Exceptions Taken Pull Station Honeywell No Exceptions Taken Duct Smoke Detector Honeywell No Exceptions Taken Relay Modules Honeywell No Exceptions Taken Monitor Module Honeywell No Exceptions Taken Strobes/Speaker Strobes/Speakers System Sensor, Eaton No Exceptions Taken Explanation of Action: • _ No exceptions Taken No deficiencies noted. Do not include in subsequent resubmittals. Make Corrections Noted Minor deficiencies noted for correction. Do not resubmit or include in subsequent resubmittais. Revise and Resubmit Significant deficiencies noted which require correction. Resubmit corrections for review. INot Reviewed Item is either not a required submittal per specifications or has been previously reviewed and resubmittal I not required. TTSD Templeton Pre-K Conference Center - 20-11.07 pae-engineers.com I 1 June 3, 2021 .=a • Remote Test Station w/key System Sensor No Exceptions Taken Resistor Harness Simplex No Exceptions Taken Fire Alarm Shop Drawings Johnson Controls No Exceptions Taken The above submittal data has been reviewed only for conformance with the design concept and for compliance with information given in the Contract Documents, and this review does not extend to means, methods, techniques, sequence of construction, dimensions, quantities, or safety precautions thereto. Review does not relieve the Contractor from responsibility for variations from the requirements of the Contract Documents. Sincerely,j�jj!/► tz Mike Streb 4r MFS/kes • • i , Transmittal of Submittal Page 1 r842--Templeton Pre-K, Conference Center& • elimeeDistrict Services CONTRACTORS To: Deca Architecture Inc. Spec Section Num: 283000 Attn:Beth Cantrell Submittal: 283000-1.0 935 SE Alder St., Revision: Portland,OR 97214 Date: 5/12/2021 Submittal Title: Fire Detection and Alarm- PD+SD Submittal Detail: We are transmitting the following Submittal(s)for your review. 283000 — 1.0 Fire Detection and Alarm— PD + SD Please review and respond to Mariel Herrera by 5/26/21. • Sincerely, Mariel Herrera CC: • Triplett Submittal Stamp Page Wellman CONTRACTORS General Contractor Stamp: Project Name Triplett Templeton PreK Wellman ❑✓ REVIEWED ❑REJECTED ❑ MAKE CORRECTIONS ❑NOT REVIEWED BY Mariel DATE 5/12/2021 SUBMITTAL# 283000-1.0 SPEC 283000 This review is only for general conformance of the project and general compliance. Corrections or comments made on these drawings during this review do not relieve Contractor/Subcontractor from compliance with the requirements of the plans and specifications. Contractor is responsible for all dimensions and fabrication to be confirmed and correlated at the job site Architect Stamp: X NO EXCEPTIONS NOTED CI MAKE CORRECTIONS NOTED • 0 REVISE AND RESUBMIT SUBMIT ITEMS AS NOTED Checking is only for general conformance with the design concept of the project and general REFER TO ABOVE PAE compliance with the information given in the contract documents, Any action shown is SUBMITTAL REVIEW subject to the requirements of the plans and DATED JUNE 3, 2021 specifications. Contractor is responsible for dimensions which shall be confirmed and correlated at the jobsite,fabrication processes and techniques of construction,coordination of the work with that of all other trades and the = Consultant Stamp: satisfactory performance of the work. deas.iao r By: Dated: 06.11 .21 • PORTLAND ELECTRICAL CONSTRUCTION, INC. pEci 101E 7TH STREET OREGON CITY,OREGON 97045 PORTLAND ELECTRICAL CONSTRUCTION INC. P 503.655.2281 I F 503.655.5033 PORTLAN DELECTRI CAL.CO M PRODUCT DATA SUBMITTAL TEMPLETON CORE 9500 SW MURDOCK STREET,TIGARD,OREGON 97224 OWNER: TIGARD-TUALATIN SCHOOL DISTRICT FIRE DETECTION AND ALARM 6960 SW SANDBURG STREET,TIGARD,OR 97223 Phone:(503)431-4000 28 30 00 ARCHITECT: DECA ARCHITECTURE INC 935 ALDER STREET,PORTLAND,OR 97214 Phone:(503)239-1987 ENGINEER: PAE ENGINEERS 22 SW 5TH AVENUE,#1500,PORTLAND,OR 97204 Phone:(503)226.2921 GC: TRIPLETT WELLMAN CONTRACTORS 17178 MTJEFFERSON AVENUE,W00DBURN,OR 97071 Phone:(503)982-4188 •CTRICAL: PORTLAND ELECTRICAL CONSTRUCTION, INC 1019 7TH STREET,OREGON CITY,OR 97045 Phone:(503)655-2281 • SERVING OREGON AND WASHINGTON SINCE 1986 LICENSED AND BONDED,CCB#51764E WASHINGTON LIC:EC PORTLECO23P PAGE 9_ ?1 1 Honeywell ( Intelligent Fire Panel with Voice pal SILENT" NW KNIGHT 6820EVS Emergency Voice System and Fire Alarm . . Control Panel The 6820EVS is a fire alarm control panel(FACP)and emergency mass - - notification system conveniently integrated and housed in one panel,and _i meets the requirements for mass notification as described in UL 2572. e The 6820EVS is a direct replacement for the 5820XL-EVS panel.The 6820EVS can be configured to achieve an overall point capacity of up to 1110 points and connect up to 17 panels in a single communications link. The 6820EVS has one built-in signaling line circuit(SLC),which can 6820EVS support 159(SK)System Sensor'sensors and 159 SK modules or 127 buildings where new wiring is not allowed,or to (SD)Hochiki'devices per loop.To increase point capability,additional SLC provide an easy install fire system for new loops can be added using the 6815 SLC expander for SK devices or the construction projects.SWIFT devices can be 5815XL expander for SD devices,increasing the point capacity to a combined with other hard-wired 6820EVS maximum of 1110 points for SK devices and 635 points for SD devices. compatible devices. Three additional SLCs are needed to reach 1110 points(SK devices).Four The 6820EVS has a form-C trouble relay,and two additional SLCs are needed to reach 635 points(SD devices). programmable form-C relays,along with powerful • The common communications and annunciation link allows up to 17 features such as drift compensation,pre-trouble panels to be connected via copper or fiber optic cable.A designated panel maintenance alert,a built-in sensor test to is configured as the communicator for all panels in the link for convenient comply with NFPA 72 calibration testing single-point communications.It also has a built-in,dual-line POTs and IP requirements,and calibration trouble alert.The communicator with optional cellular reporting available. 6820EVS supports a variety of devices,including the 6860,5860,and 6855 remote annunciators, The emergency communication system operations include an onboard 5824 serial parallel printer interface module(for supervised microphone,and all-call and non-active call buttons can printing system reports),the 5496 NAC expander, quickly select all active or all non-active output groups.The system also 5895XL power module,and SK or SD devices. allows for ECS messages to take priority over fire. The panel also has four user-programmable SWIFT wireless compatibility provides options for wireless detection buttons which are ideal for programming simple, through a Class A mesh network.It is ideal for hard-to-wire locations, complex,and routine tasks. FEATURES & BENEFITS • Up to 1110 points for • 15 recordable one • Built-in annunciator • JumpStart5 auto • Programmable date greater design minute messages can with a large 160 programming feature setting for automatic flexibility.Additional be mapped to eight character,4 x40 LCD for easy programming and Daylight Saving SLCs can be added different EVS buttons display Time changes • Built-in dual path until maximum point • Built-in USB interface • Four user- POTS and IP • Flexpute'circuits can levels are reached for convenient programmable communications with be individually • Connect up to 17 programming buttons minimize time optional cellular programmed to panels on one site with . Convenient spent executing models available for function as convenient single- complex or routine reliable backup notification circuits, • field-upgradeable point access; tasks reporting auxiliary power firmware compatible with mixed outputs,or initiating •FACP models 16 built-in speaker circuits that support group switches; expandable to 32 both 2-and 4-wire smoke detectors SIGNAL LINE CIRCUIT(SLC) alarm, supervisory,system trouble, Suitable for automatic,manual,waterflow, The 6815 signal line circuit(SLC) system silenced and system power, sprinkler supervisory(DACT non-coded) signaling services. • supports multiple device types of SK System operations include silencing UL Listed:S2766 protocol,while the 5815XL signal line alarms and troubles,resetting alarms CSFM 7165-0559:0500 circuit(SLC)supports multiple device and the display of alarm troubles and FDNY COA#6249 types of SD protocol.You cannot mix memory.The system's non-volatile event FM approved SD and SK SLC devices on a FACP. history buffer stores 1,000 events for UL listed for Continuous or ANSI 520Hz viewing from the built-in or remote speaker tones that meet NFPA 72 Low The 6820EVS has one built-in annunciator.System operations can be Frequency Signal Requirements for signaling tine circuit(SLC)which initiated with a mechanical firefighter's Sleeping Areas when used with the EVS- supports multiple devices.Additional key or a valid 4-to 7-digit operator's INT5OW or EVS-100W amplifiers and points can be added using up to three code. compatible speakers 6815 SLC expanders to increase overall capacity to 1,110 maximum PROGRAMMING ORDERING INFORMATION points(SK devices)or by adding The 6820EVS system offers several 6820EVS:Emergency Communication up to four 5815XL SLC expanders options to simplify and speed-up System with FACP.(Red cabinet). to reach 635 maximum points(SD programming.JumpStart® COMPATIBLE ANNUNCIATORS devices).The number of SLCs which AutoProgramming minimizes required to start a new 6860:4x40 LCD remote fire annunciator can be used within one system is programming s stem.The built-in keypad,or the 6860, (4 lines and up to 160 characters)per only limited by point count.(See the Y yP 5860 or 6855 remote annunciators give system;four programmable buttons Manual for additional information.) you on-site access to current system 5860:4x20 LCD remote fire annunciator. The 6820EVS SLC loops support 5860 is gray;5860R is red multiple device types,maintenance programming.Programming can also be accomplished using the Windows•- 6855:4x20 LCD remote fire annunciator alerts,and a built-in sensor test to 5865 3/5865 4:LED annunciators can comply with NFPA72calibration basedHoneywetlFireSoftwareSuite • (HFSS)program. display up to 30 LEDs(15 red and 15 testing requirements. SOFTWARE TOOLS yellow).The 5865-4 has key switches for INDICATOR LIGHTS silence and reset,and a system trouble SKST:Silent Knight Selection Tool • General Alarm(Red): Flashes if in LED. provides the installer or design architect alarm;solid when alarm is silenced with a Windows®software system 5880:The 5880 LED/10 module • Supervisory(Yellow):Flashes if a has 40 programmable LED outputs and configuration tool to create a detailed Bill supervisory condition exists;solid eight supervised dry contact inputs of Material(BOM)and battery when supervisory is silenced which are useful for custom applications. calculations. • System Troubles(Yellow):Flashes You can use up to eight 5880 modules HFSS:Honeywell Fire Software Suite if a trouble condition exists;solid on one control panel for maximum provides communication and panel when trouble is silenced flexibility. • System Silenced(Yellow):On programming,detector status,event when an alarm,trouble or history and additional data.Requires a 6820EVS COMPATIBLE DEVICES AND supervisory condition has been PC running Microsoft®Windows®. ACCESSORIES u p y See the data sheets listed below for a silenced but not yet cleared ADDITIONAL INFORMATION complete listing of the SK,SD or SWIFT • System Power(Green):Flashes for Twisted-unshielded pair wire is devices. AC failure;solid when power recommended.The 6820EVS also has 53623:SK Devices Data Sheet 53624:SD Devices Data Sheet systems are normal 13 preset notification cadence patterns 350614,350616&350618:SWIFT (including ANSI 3.41). wireless devices USER INTERFACE For a complete and current listing of The 6820EVS built-in 4 x 40 AGENCY LISTINGS AND APPROVALS compatible devices and accessories,visit annunciator with 160 character LCD NFPA 13,NFPA 15,NFPA 16,NFPA 70, www.silentknight.com display and large easy-to-use tactile NFPA 72:Central station;remote Important:You cannot mix SK and SD • Signaling; Local Protective Signalingdevices in the same fire alarm system. touchpad can be used for system g g operation,programming and Systems;Auxiliary Protected Premises maintenance. It has five LEDs for Unit;Water Deluge releasing service. Page 2 of 4— 351606:B 9/26/2018 SK COMPATIBLE ADDRESSABLE B200S-LF:Low-frequency intelligent WSK-PHOTO-T:Wireless Multi-criteria DEVICES sounder base photoelectric smoke detector with thermal SK-ACCLIMATE:Multi criteria B224RB(-IV,-WH):Relay base detection(135°F fixed temperture)and photoelectric smoke detector with thermal B510W 4"base ° B224RB: Relay base 135 Ffixed temperature g224BI(-IV, WH):Isolator base WSK-HEAT:Wireless Heat,(135°F fixed SK-BEAM:Reflected beam smoke detector B224BI: Isolator base temperture)and B510W 4"base without test feature WSK-HEAT-ROR:Wireless heat,ROR SK-BEAM-T:Reflected beam smoke SD COMPATIBLE ADDRESSABLE (135°F fixed temperture)and B510W 4" detector with test feature DEVICES base SK-CONTROL:Supervised control module SD505-6AB:Addressable 6"base WSK-MONITOR:Wireless monitor module SK-CONTROL-6:Six circuit supervised SD505-6IB:Addressable 6"short circuit WSK-RELAY:Wireless relay module control module isolator base SK-DUCT:Photoelectric duct smoke SD505-6RB:Addressable 6"relaybase W-USB:SWIFT Toots USB transceiver used detector with extended air speed range SD505-6SB:Addressable 6"sounder base for communication with SWIFT devices SK-FIRE-CO:Four criteria fire and carbon SD500-AIM:Addressable input module SBUS ACCESSORIES monoxide detector (switch input) 6815:Each Single Line Circuit allows for SK-HEAT:Fixed thermal detector(135°F) SD500-ANM:Addressable notification an additional 159 SK modules and 159 SK SK-HEAT-W:Fixed thermal detector module sensors to be added to the system-up to (135°F),white SD500-ARM: Addressable relay module 1,110 total points.Supports System Sensor SK-HEAT-ROR:Fixed rate of rise detector SD505-DTS-K: Remote test switch and SK devices only. (135°F) LED indicator for the SD505-DUCTR 5815XL:Each Single Line Circuit provides SD505-DUCT:Addressable Duct Smoke an additional 127 SD devices to be added to SK-HEAT-ROR-W:Fixed rate of rise Detector. the system-for a maximum of 635 points. detector(135°F),white SD505-DUCTR:Addressable Duct Supports SD devices only. SK-HEAT-HT:Fixed high temperature Detector housing with relay base. 5496:A 6 amp notification power expander thermal detector(190°F) SD505-H EAT:Absolute temperature heat with four power-limited notification SK-HEAT-HT-W:Fixed high temperature detector.Trip point range from 135°F-150° appliance circuit outputs. thermal detector(190°F),white F(0°C-37°C). 5883:Relay Interface.Provides 10 Form C SK ISO:Fault isolator module SD500-LIM:Addressable Line isolator relays. SK-MINIMON:Mini monitor module module 5824:Serial/Parallel Printer Interface SK-MONITOR:Monitor module SD500-MIM:Addressable Mini input Module for printer connection. SK-MONITOR-2:Dual input monitor monitor module(switch input) 5895XL:Power Supply with six Ftexput" •module SD505-PHOTO:Photoelectric smoke circuits,and two Form C relays.Max.16 per SK-MON-10:10 input monitor module detector system. SK-PHOTO:Photoelectric smoke detector SD500-PS/-PSDA:Addressable Single or 5815RMK:Remote mounting kit. SK-PHOTO-W: Photoelectric smoke dual action pull station Dimensions 10 3/8"W x 10-3/16"H x 3'D detector,white SD500-SDM:Addressable smoke detector SK-PHOTO-T:Photoelectric smoke detector module EVS ACCESSORIES with thermal(135°F fixed temperature) EVS 50W:50 Watt Amplifier* AUDIBLE/VISIBLE DEVICES These AV EVS-125W:125 Watt Amplifier* SK-PHOTO-T-W:Photoelectric smoke devices are all 2-wire.Color:°R"indicates EVS-100W:50/100 Watt Amplifier* detector with thermal(135°F fixed red;°W"denotes white.For a complete EVS-100WBU:External Backup Amplifier temperature),white listing of Silent Knight AV devicesgo to EVS INT50W:50WattlnternatAmptifierSK-PHOTOR:Photoelectricdetectorwith remote test capability www.silentknight"com. EVS-CE4:Circuit Audio Expander SK-PHOTO-R-W: Photoelectric detector CHSRL/CHSWL:Wall chime/strobe EVS-SW24:24 Switch Expander with remote test capability,white CHSCRL/CHSCWL:Ceiling chime/strobe EVS-VCM:Voice Control Module SK-PULL-SA:Addressable single action CH RL/CHWL:Wall chime EVS-LOC:Local Operator Console** pull station HRL/HWL:Wall horn SK-PULL-DA:Addressable dual action pull *Support for to four amplifiers; station P2RL/P2WL:Wall horn/strobe maximum.Each amplifier has500W four built-in SK RELAY:Addressable relay module SK- PC2RL/PC2WL:Ceiling horn/strobe speaker circuits expandable to eight. RELAY-6:Addressable Six relay control SRL/SWL:Wall strobe **Supports up to four EVS-LOCs module SCRL/SCWL:Ceiling strobe SK-RELAYMON-2:Addressable Dual SPSCRL/SPSCWL Ceiling speaker/strobe COMMUNICATION OPTIONS relay/monitor module SK ZONE Addressable zone interface SPSRL/SPSWL•Wall speaker/strobe CELL-CAB-SK:Cellular communicator, module SPRL/SPWL:Wall speaker metal enclosure with lock/key* SK-ZONE-6:Six zone interface module SPCRL/SPCWL:Ceiling speaker CELL-MOD:Cellular communicator,plastic B300-6(-IV):6"base for SK-W Series enclosure* B210LP:6"mounting base SWIFT WIRELESS DEVICES *Sole path,powered by panel. B501(-BL,-IV,-WHITE):4"flangetess base SWIFT is only compatible with System IPGSM-4G:Dual path fire alarm B501:4"Flangelessmountingbase Sensor(SK)devices.Itisnotcompatible communicator,cellular and/or IP(primary •B200S(-IV,-WH):Intelligent sounder base with Hochiki(SD)devices. or backup,selectable) B200S:Intelligent sounder base SK-IP-2:Remote reporting via the Internet. 9 WSK-WGI:Wireless Gateway Requires a VisorAlarrn°receiver at the B200S-LF(-IV;WH):Low-Frequency WSK-PHOTO:Wireless Photoelectric smoke central station intelligent sounder base detector Page 3 of 4—351606:B 9/26/2018 6820EVS Technical Specifications • MISC.ACCESSORIES ELECTRICAL Flexpute,Honeywell°, SK-NIC:Network Interface Card.Provides a 682OEVS Primary AC:120AC @ 6OHz,3.3A Total JumpStarte,Silent Knights, common communications link for the 682OEVS. Accessory Load:6A @ 27.4VDC power-limited SWIFT®,and System ed (Panels cannot be linked together for peer-to-peer StandbyCurrent:190mA trademarks are of Honeywell trademarks Honeywell networking). Alarm Current:250mA International Inc. SK-N IC-KIT:Installation Accessory Kit Battery Charging Capacity:7 to 35AH SK FML:Fiber Optic Multi Mode,transmitter and H E is a registered Battery Size:18AH max.allowed in control panel trademark of Hochiki receiver cabinet.Larger capacity batteries can be housed in Corporation.Microsoft SK-FSL:Fiber-Optic Single Mode RBB:Remote RBB accessory cabinet. and Windows°are battery box accessory cabinet or batteries that are registered trademarks of too Large to fit in the FACP cabinet.Dimensions:16" Microsoft Corporation. Wx 10"H x 6"D(406mm Wx 254mm H x 152mm Six conductor wiring:4 SBUS and 2 Voice Bus D) This document is not SK-SCK:Seismic Compliance Kit used to securelyFLEXPUP CIRCUITS intended to be used for p Slx programmable circuits which can be installation purposes.We fasten batteries to the fire panel. programmed individually as: try to keep our product information up-to PHYSICAL Notification Appliance Circuits:3A®27.4VDC date and accurate.We per circuit,power-limited(with a panel maximum cannot cover all specific Overall Dimensions:21.59"W x 28.1"H x 5.05"D current of 6A) applications or anticipate Shipping Weight:50 lbs. Auxiliary Power Circuits:3A®27.4VDC per circuit, all requirements.All Color:Red specifications are subject power-limited to change without notice. Initiating Circuits(Circuits 5 and 6 Only):1O0mA ENVIRONMENTAL @27.4VDC circuit,powerlimited For Technical Su per pport,call Operating Temperature:32°F to 120°F (0°C to 800 446 6444. 49°C) Supports Class B(Style 4)and Class A(Style 6) Humidity:0 to 93%relative humidity(non- configuration for SLC,SBUS,and Flexput circuits condensing WIRING:See the product manual for wiring details • Honeywell Silent Knight ID12 Clintonville Road Northford.CT06472 Honeywell 800-328-0103 351606 I B 109/18 t elSILENT' www.silentknight.com ©2018 Honeywell International Inc. Wadi KNIGHT Honeywell • SILENT' El KNIGHT -------- - EVS-100W Intelligent 50/100 Watt Amplfier with optional. backup Amplifier The EVS-100W is an intelligent 50/100 watt amplifier for use with Version 14.0 or newer 5820XL-EVS or the 6820EVS.The EVS-100W is used to amplify audio message for distribution throughout a facility.The EVS- 100W is capable of producing up to 100 watts of audio power and has the ability to provide an option for 50 watts of backup power. Description . The EVS-100W has its own power supply with battery backup and eight speaker circuits.The EVS-100W is fully supervised by the main panel for trouble conditions EVS-IOOW Amplifier Configurations: • 50 watts with 50 watts as backup. • 100 watt single channel. • 100wattsinglechannetwith 50watts backup using EVS-100WBU• COMPATIBILITY The EVS-100W is compatible with the following Honeywell Silent Knight Series FACPs: • 6820EVS:Addressable fire alarm control panel with an emergency voice system,up to 1,110 addressable points,and four programmable buttons that can be programmed for routine or complex tasks • 5820XL-EVS:Addressable fire alarm control panel with an emergency voice systems and up to 792 addressable points FEATURES & BENEFITS • Built in backup • Amplifier Bandwidth • Can be mounted up to • UL listed for • 120 VAC or 240 VAC amplifier test feature 400 Hz to 4000 Hz 6000 feet away from Continuous or ANSI operation allows you to . Six-wire connection to 5820XL-EVS or 520Hz speaker tones physically test that the EVS system:Two-wires 6820EVS control that meet NFPA 72 backup amplifier is for the voice bus and panel Low Frequency Signal operating properly Requirements for four-wires for the • UL 864 and UL 2572 • Up to four amplifiers SBUS connections Sleeping Areas.See per 5820XL-EVS or the FACP manual for a 6820EVS distributed list of compatible • between up to 32 speakers audio circuits EVS-100W Technical Specifications For a complete listing of all • compliance approvals and PHYSICAL ORDERING INFORMATION certifications,please visit Flush Mount Dimensions:14.5"W x 24.75"H x EVS-100W:Intelligent50/100 Watt Amplifier www.silentknight.com. 3.4"D(36.8 W x 62.9 H x 8.7 0 cm) Microsoft,Windows,and Overall Dimensions:16.1"W x 26.5"H x 4.1"D(40.6 ACCESSORIES the Windows Logo are W x 66.7 H x 10.5 D cm) EVS-100WBU:External Backup Amplifier registered trademarks or trademarks of Color:Red. RBB:Remote Battery Box Accessory Cabinet.Use Microsoft Corporation. for backup batteries up to 35AH • ENVIRONMENTAL Silent Knight"and Operating Temperature:32I -120 Bi (0R- AGENCY LISTINGS AND APPROVALS Honeywell°are registered 49E) UL 864 and UL 2572 trademarks of Honeywell International,Inc. Humidity:10%-93%non-condensing Meets the requirements for NFPA 72 Local Protective Signaling Systems&Emergency This document is not ELECTRICAL Communication Systems. intended to be used for installation purposes.We Primary AC:120VAC @ 60Hz;240VAC @ 50Hz CSFM:7165-0559:0500 try to keep our product Standby Current:EVS-100W 25V 110mA;EVS- information up-to 100W 70.7V 110mA date and accurate.We Alarm Current:EVS-100W 25V,1.2 A;EVS-100W cannot cover all specific 70.7V,1.4 A applications or anticipate all requirements.All Total Power:100W@25VRMSor70.7ARMS sppecificationss are subject •Circuit 1-4:50 W max. to change without notice. •Circuit 5-8:50 W max. For Technical Main EVS Panel SBUS Standby&Alarm:10mA Support.Please call Battery Charging Capacity:7-35AH 800-446-6444. Battery Size:18AH max allowed in cabinet.Use RBB accessory cabinet for larger batteries up to 35 AH per system. Voice Integration Wiring: • Six conductor • • Two voice bus • Four SBUS For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com • HoneywellSilent Knight Honeywell 12 Cli nto nv lie Road stun�"r Northford.CT 06472 13 xvMr Doc 3509611 Rev El 05/18 800-328-0103 ©2018 Honeywell International Inc. D S C • From Tyco Security Products W b W � �.Pf� 4 <�. 4F# F . f $r A+ v , e . sr 4.k s r 4 � i '' iiii 11111' gym.u �e "410 0 R Pam_ e TV t,: I ar 'TMi 5-,h $i4 t 't Cornmercial onitorin • Solution ,,10. T DSC -- The Most Trusted Name In Fire Monitoring E .. .�- v.,.i,. --. eurommemmommemimp. illiniima cry�k a44f V ..+w.§ .8 gyp. • w 4-.8 Ti_ ___ __ _ , .., , hi r. ,, s a� • .b:..`i... e 9 • Introduction Product Features 3 Approval Information 4 Installation Information 5-6 Wiring Diagrams 7-9 Frequently Asked Questions 10-12 Appendix A: NFPA72 Compliance 13 Clarifications on NFPA72 13 Appendix B: UL Listing Guide • • $ I . 4 Iwo now. 6- 111111 11.111111111111111 jf • e, x u. MOM e t The increasing adoption of new technologies,such as cellular and IP communications and the shift away from plain old telephone lines (POTs), has led the National Fire Protection Association (NFPA)to expand and elaborate these new communication technologies to their latest standards of the NFPA72,2010 Edition. In order to meet the requirements of a communicator deployed for commercial fire applications,the standard has specified,among other things,that: • communication paths must be monitored and any failure of the communication path shall be announced at the supervising • station within 5 minutes of the failure • the battery backup needs to provide 24 hours of standby current DSC's 3G3070-CF and T-Link TL300/IL300CF are UL listed as sole path communication systems for fire control panel communications with cellular and IP communications respectively. In order to obtain this listing,these products were thoroughly tested as per the UL864 9th Edition and UL1610 Standards. The IP alarm communicator models 3G3070-CF and T-Link TL3O0CF are FM approved for use as a single communication technology when the heartbeat supervision is enabled at the Supervising station compatible receiver.These communicators can also be used in a back-up configuration in conjunction with an approved DACT communicator. The 3G3070-CF and the T-Link TL300/TL300CF can now be installed in certified installations in accordance with the requirements of UL827 Standard and NFPA72 2002(Section 8.5.4 Other Transmission Technologies), NFPA72 2007(Section 8.6.4 Other Transmission Technologies)or NFPA72 2010 Code (Section 26.6.3.1).Refer to'Appendix A' for details for compliance with NFPA72 current edition. The complete cellular and IP CF kits include 24 hour battery backup, power supply(powered from 120VAC connection), as well as supervision setup for fire applications.The standalone TL300/TL300CF can be powered directly off of any UL listed power supply rated from 12 VDC- 24 VDC. The 3G3070-CF is programmed using C24 Communications(www.connect24.com)and the TL300/TL300CF is programmed manually. The 3G3070-CF and the TL300ITL300CF are compatible with listed alarm control panels that have an integrated Digital Alarm Communication Transmitter(DACT) and support a 4 or 10 digit Contact ID Communication Format.They are designed to work with the Contact ID communication format as described in SIA DC-05 Standard. Alternatively,these units can also be setup solely with the dry contact outputs from the panel to the zone inputs of the communicators. ighTelephone lines over voltage protection and monitoring with automatic switch over to the cellular/IP network communication path when a phone line trouble condition exists are also provided.Please see following page for detailed product features on both communication systems. DBD TL300/TL:3000F • Product Features Product Features • Compatible with control panels that communicate using • Compatible with most control panels that use Contact ID format the Contact ID format • Full event reporting • 2-way,always-on IP communication • Uses HSPA(3G) data channel for high-speed, reliable and • Works over local LAN/WAN network or the Internet low-cost communications to an IP receiver • 128-bit AES encryption (NIST approved) • Automatically switches to 2G (EDGE/GPRS) if 3G service is • Supports DHCP(dynamic IP addresses) not available • Reports events to 2 different receiver IP addresses • 4 on-board inputs and 4 on-board outputs(open collector) • Polling and hardware substitution protection • SIM card (included) • Low network bandwidth requirements • Activation and initialization via automated telephone • Compatible with 10/100BaseT networks activation system (VRU)or web-user interface provided • Compatible with Sur-Gard System I/II/III/IV monitoring by C24 Communications station receivers • Compatible with Sur-Gard System I/II/III/IV monitoring • 4 on-board programmable zone inputs (expandable to station receivers 12 using PC5108 zone expander) • Includes UL listed power supply,transformer and 7 Ah • 2 programmable voltage outputs rechargeable battery • Programmable through the panel keypad or T-Link • 24 hour battery backup Console software • Transformer(120VAC)and Power Supply(PS4085) • 24 hour battery backup • Ships with the PC4050CR Red Cabinet for Fire Applications • Transformer(120VAC)and Power Supply(PS4085) •• 300 second Supervisory Window and programmable • Ships with the PC4050CR Red Cabinet for Fire Applications heartbeat intervals • 300s Supervisory Window and programmable • UL Commercial Fire listed, CSFM listed and NFPA72 heartbeat intervals compliant, FM approved,NYC Fire Dept. (back-up only) • UWLC Commercial Fire listed, CSFM listed and • Cellular network connection and signal strength indicator NFPA72 compliant,FM approved Note:Before completing the field installation of the alarm monitoring system,ensure communication with the supervising station is successful by sending several events and getting confirmation that they have been received. Please contact your supervising station to review all of their requirements for onsite testing. • 2 .446.4 Iems ] -w a. e z 'Va`x a.arc . ,#41'° 4� F • Appi oval I4-1 rt.Y tior For Commercial Fire Monitoring Installations,the 3G3070-CF and the TL300/TL300CF can be used in the following configurations: 1. Sole communicator,single communication technology a. These installations require a 5 minute supervision window. b. By default,the 3G3070-CF sends heartbeats to the supervising station every 97 seconds and the TL300/TL300CF sends heartbeats every 10 seconds.These are programmable and may be changed by the installer if required. 2. Back-up communicator line for a DACT • Alarm signals must first be sent over the primary communication path (DACT), however if this fails it must then be sent over the secondary communication paths(other transmission technologies). • Primary: Compatible listed control unit's land line to supervising station. • Secondary:3G3070-CF transmission through the cellular network or TL300/TL300CF transmission through IP network to supervising station. • Every 24 hours a check-in signal must be sent to the supervising station over the primary communication path. The 3G3070-CF sends a heartbeat test transmission to the supervising station every 24 hours. • Each communication path will be monitored for integrity(DACT will have line monitoring enabled and 3G3070-CF and TL300/TL300CF will have cellular/IP network connection supervision enabled). '82 • • 3G3070-CF is not able to support connection of two DACT outputs from a CFAP with integrated dual dialer. 3 CI C ! 0C • offer for your installation? Communication Channel HSPA(3G) fall-back to EDGE/GPRS LAN/WAN network or the Internet Sole Communication Path Yes (with Supervision) Yes (with Supervision) Backup Communication Path Yes Yes Data Plan Requirement Yes ' No 24 hour Protection from Power Failure Yes Yes 3'4 Full Reporting Yes Yes 4 Zone Input Yes Yes Programming (Connect 24) Keypad/Software Router Programming No Yes Enclosure Included Included Supervisory Time 300 Seconds 300 Seconds Heartbeat Signals 97 Seconds 10 Seconds Mains Connection itttittailit,; 120 VAC Required t „ '; rcW, Y 120 VDC Required •1. When used as a sole communicator,the 3G3070-CF will use the 4 MB rate plan available from C24 Communications. Please contact your C24 Communications master reseller(Central Station)for pricing. 2. Uses existing customer Internet connection for the TL300/TL300CF 3. Unit continues to work but connection dependent on customer's Internet connection. 4. TL300/11300CF uses battery backup and power from fire panel. • 4 • Sole Communicator Configuration I Module Wiring Diagram for the 3G3070-CF This Connection is necessary A 3G3070-CF R GROUND 1 1 2 1 3 1 4 1 5 1 1 f 1 2 1 f 1 9 1 10 1 11 12 13 1 14 1 IS 1 16 1 17 1 18 1 19 20 0 -igFsnnut mbreilpum tieLn w.b 1 TIP RNG TI RI (OM Poi PGM2 PGM3 PGM4AUR+TAMPER EOM 21 Z2 Z3 Z4 +I2V- '"rgetai unwm 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 l 1 W IIN Obiat wine Earth-pound RM-2 bsitRelay k_ -..--.-..•' Connect to Power d—� Inputs to be connected ..Supply Terminals to dry contact outputs +12V/(OM Connect relay contacts to a zone from alarm control panel T rt input on the alarm control panel 12V/ImA t 1 for 3G3070-C1 troubles supervision 1 p G (24h type zone) ,Control Panel with l These inputs are typically used to interface with fire alarm panels that do ' (Supports Dialler Interfacenct Ia format)i not have a dialer interface and use the lC fire alarm, fire supervisory or fire trouble output relay contacts to send the events to the communicator. • Sole Communicator Configuration I Module Wiring Diagram for the TL300/TL300CF PC4050CRCABINET Network Connection 0 0 G I mnkTL300 I O Use only CATS cable E% (300k/100m max.) '' 41 Supervised r00000000000000000000 �0 l � y!_ T%A%GVa1EmLN AL CAN 1 PGMSe� UMW Mil AtTr rv•,on gt-im l ' To Tip and Ring QQ`a 'a MG B -on Fire Alarm B.Mr 0 O 0 Control Panel MD B ® a (If panel has an �_� integrated dialer) '•a1 PS4005 mounted 0 b� ,iJ on the slde ofthe Cable Tie(not provided) cabinet O To batteries, wires fromfallinge 0' onto batteries,secure them yy cablene to the enclosure 01. a - WARNING!HIGH VOLTAGE re '= DISCONNECT POWER nm LINES PRIOR TOElm SERVICING 0 TRANSFORMER exceptAll circuitsd C10 td Primary AC and Battryonth8simeouohe I I cabinet qa BLACK RED n 8 Airef 11 BATTERY 8 `' r Model DSC BD12-7 lei 12V/7Ah 5 ® 0G Power Supply Wiring Diagram I 3G3070-CF and TL300/1L300C / ULC-LA Cabinet WARNING!:HIGH VOLTAGE AC Indicator' P�O85 DISCONNECT POWER LINES �� PRIOR TO SERVICING ,,,,. I.-1,..,...„, +12VCOM ACT LBT TEST +BAT-BAT C Primary -' SPECIAL APPLICATION IOUTPUT ‘ 120VAC RATII%11.5 VDC-12.6VDC 60Hz,0.3A, 700mA max.Use for DSC,odel !` TRANSFORMER M3630730Bor6{P TEST-CHARGER TROUBLE OUTPUT 50mA,12V Max. U 0 G307 ATC Frost Model FTC371 6 L8T-LOW BATTERY OUTPUT 50mA,12V Max. + — ACT-AC FAILURE OUTPUT SomA,12V Max. BATTERY *NOTE:For ULC installations,the ULC-LA Cabinet AC Indicator 12V 7.OAh shall be connected to the output of the Class 2 Transformer and installed in one of the knock-offs on top of the cabinet. / illTeptd 30T30CF (Notel requiredhoneconnec when 3G3070ion13G3070-CF CF and T an LINKTL TL300/0/ L TL3000CF are used as a stand-alone devices) CONTROL PANEL ,v RJ-31X Incoming ■ Handset Phone Line _ O OJ m < Z TO z Z 22 4 1 2 3 4 5 3G3070-CF • = TIP RNG T1 R1 6 F.requently AskedQuestions • How reliable are the communication paths given that these units can be used as sole communicators? The 3G3070-CF and the TL300/TL300CF are built to be robust enough to be used as sole communicators and can withstand most network issues or network congestions.They use the"constant connection"feature of cellular networks and the Internet to communicate heartbeats to the central station every couple of seconds. If the unit fails to communicate its presence in a given time window,the receiving station is alerted with an account absent message.This feature is called "Account Supervision". What happens if there is a power failure? Because modern cellular networks continue to work during a local power outage,the 3G3070-CF is not affected by power outages and will continue to work for 24 hours following any such outage.TL300/TL300CF also continues to work during a local power outage. However, you need to ensure that the routers in the TL300/TL300CF that are connected at your premises, have 24 hour power backup. In the unlikely event that power goes out,and the power backup built into these units fails to operate,the supervising station will see a network absent message. How does supervision work? • In order to monitor the communication path,the 3G3070-CF sends a heartbeat signal every 97 seconds to the supervising station.The TL300/TL300CF sends a heartbeat every 10 seconds.These are the default values and may be changed by the installer if required. • If the receiver misses three consecutive heartbeats within a 300 second window,an "Account Absent Message"is • generated at the supervising station.The receiver must then receive 2 consecutive heartbeats to restore the condition. Note:It is recommended that the procedure for responding to such messages by the supervising station are established/discussed with the owner of the protected premises. What programming information do I need to setup these units? • For the TL300/TL300CF you will need the following information: — Account Number — Receiver IP 4 — Receiver port' • For Static IP Addresses Only: — IP address 5 — Subnet mask 5 — Gateway — Port 3060 and port 3061 on the router must be open for alarm communication for remote programming — Setup TCP port 3064 forwarding on router(please refer to router manual/manufacturer for details) • For the 3G3070-CF,you will need the following information: — Account Number 4 — Receiver IP 4 — DNIS 4 4-Please contact you supervising(central)station to obtain 5-Please contact your local network operator to obtain • 7 ID c Can I power the TL300/TL300CF from a fire panel? • The TL300/TL300CF may be powered from a 12VDC to 24VDC on a fire panel.However,you will need to ensure that panel battery is sufficient to provide 24 hour backup. How can I test if I have installed the unit correctly? How can I test for AC trouble, low battery trouble, and network trouble? AC trouble and low battery trouble: • Remove the AC power • Panel should show zone trouble (Remember to ensure the AC Power/Low Battery Outputs from the Power Supply (PS4085)are connected to the fire panels zone inputs) Network trouble: • Remove Network cable for TL300/TL300CF and/or remove antenna connector for 3G3070-CF • Fire panel should show trouble light and the supervising station should show loss of connection within 300 seconds Note:Please make sure to always connect the battery first when powering up the units. How can I troubleshoot these devices? Please refer to the installation manual for troubleshooting instructions. What are the supervising station requirements for these products? •The TL300/TL300CF/3G3070-CF work with the following supervising station receivers: • A System I (Firmware version 1.0 and higher current version is 1.12) • A System I1 (Firmware version 1.1 and higher current version is 2.02) • A System III receiver with 1 DRL3-IP line card (Firmware version 1.91 and higher) • A System IV receiver with DRL4-IP line card (Firmware 1.0 and higher) Are there any specific Fire Panel compatibility requirements? For full communication,the Fire Alarm Control Panel (FACP) must be able to communicate in DTMF Contact ID format and have a zone available for connection to the PS 4085 power supply trouble outputs to show trouble on the fire alarm control panel.The TL300/TL300CF and 3G3070-CF may also connect to the FACP if outputs for alarm,trouble and supervisory from the FACP are available. Can I install the two phone lines from the panel in parallel into these units? Please note that these units are designed to take only one phone line input.Do not install the second phone line in parallel. You should disable the second phone line in the panel.Please contact your panel manufacturer for more details on how to disable the second phone line.These products will not operate correctly if two or more DACT's lines are connected to the R-1/T-1 terminals of the Cellular/IP communicator. There should only be a single pair connected between R-1/T-1 of the Cellular/IP Communicator to the Ring/Tip of the DACT respectively,with no additional lines connected in parallel. • 8 { r a • tT!. 1 of h l kJi � 4 a9l L 77 z - tea. ) _... - St * i s . fie., _ .0 , , • 0 ./ 1 i il ilpHil y� - �� t' rt yyY x IA- k•n1 k S f What additional parts can I order separately? TL300/TL300CF • Zone Expander(PC5108) 3G3070-CF • Dual band antenna with extension wire: GS-15'Antenna(GS 15ANT), GS 25'Antenna(GS-25ANT), GS-50'Antenna(GS 50ANT} Can these units be installed in the Fire Panel enclosures? No.These units come with their own enclosure and cannot be installed inside other fire panel enclosures. Please ensure that all cabinets are installed as per the UL Standards. • 9 DSC ix A: NFPA72 2010Compliance e ,Criteria NFPA72 2010 Edition 3G3070-CF T Link TL300/TL300CF � r�ro. yy Iequirements Compliance Compliance FCC approval when applicable. Yes FCC ID:F53113G3070 N/A UL Listing UOXX.S4019.Compliant UL Listing U0XX.S4019.Compliant Conform to NFPA70,National Electrical Yes with UL864 9th Edition(uses with UL864 9th Edition(uses Code. hardwired transformer installed in the separately listed power supply). earth grounded enclosure). Heartbeat transmitted by the Heartbeat transmitted by the T-Link Monitoring for integrity of the transmission Monitor for integrity or provide 3G3070-CF to the Supervising Station TL300/TL300CF to the Supervising and communications channel. backup channel tested as below. (use SG-System I,II,III or IV UL listed Station(use SG-System I,II,III or IV receiver)every 97 seconds. UL listed receiver)every 10 seconds. If the Alarm Receiver(SG-System I,II, If the Alarm Receiver(SG System III,IV)used at the Supervising Station I,II,Ill,IV)used at the Supervising Annunciate,at the supervising station, Station does not get the heartbeat Within 5 minutes(can use a second does not get the heartbeat within the within the programmed supervision the degradation and restoration of the separate path to report failure). programmed supervision window of transmission or communications channel. 5 minutes an"AccountAbsent"alarm window of 5 minutes,an"Account message is generated by the receiver. Absent"alarm message is generated by the receiver. Redundant communication path Provide a redundant path if where a portion of the transmission or The HSPA network is a redundant The Internet/Intranet is a redundant communications channel cannot be communication failure not network within itself. network within itself. monitored for integrity. annunciated at supervising station. If backup path required,test path once every 24 hours on alternating Not applicable if supervision window Not applicable if supervision window • Interval testing of the backup path(s). channels,testing each channel is set to 5 minutes. is set to 5 minutes. every 48 hours. Local visual and/or audible trouble is Local visual and/or audible trouble is generated at the protected premises generated at the protected premises when the cellular network is lost Systems where the transmitter at (yellow LED is turned ON and PGM4 when the IP communication channel the local premises unit detects a is lost.The PGM output is connected Annunciation of communication failure or communication failure before the output is also activated).The PGM4 to an input on the Fire Control Panel ability to communicate at the protected supervising station,the premises output is connected to an input on in order to annunciate visually the Fire Control Panel in order to premises. unit will annunciate the failure and audible the trouble condition annunciate visually and audibly the within 5 minutes of detecting the at the user interface.Trouble failure. trouble condition at the user interface. condition annunciation within 90 Trouble condition annunciation within seconds after detection of Toss of 90 seconds after detection of loss of communication. communication. Where duplicate equipment not provided,spare hardware required Time to restore signal receiving, so a repair can be effected within processing,display,rsign and srignal-receiving, ng, 30 minutes.Complete set of critical Not applicable,this is a requirement Not applicable,this is a requirement equipment. spare parts on a 1 to 5 ratio of for Alarm Receiving equipment. for Alarm Receiving equipment. parts to system units or a duplicate functionally equivalent system unit for every five system units. • 10 • Criteria NFPA72 2010 Edition 3G3O7O-CF T-Link TL3OO/TL3O0GF s•Ur'eCT1=p„ A.a,a:x-&:�r.. Compliance Compliance 512 independent alarm systems on a system unit with no backup. Unlimited if you can switch to The SG-System I,II,III,IV can Loading capacities for system units a backup in 30 seconds.The The SG System I,II,III,IV can handle handle 512 supervised accounts. and transmission and communications system must be designed such 512 supervised accounts.SG System SG-System III and SG-System IV channels. that a failure of a transmission III and SG-System IV are capable of are capable of fully redundant channel serving a system unit fully redundant configurations. configurations. must not result in the loss in the ability to monitor more than 3000 transmitters. All messages exchanged between 90 seconds from initiation of alarm protected premises and supervising End-to-end communication time for an until displayed to the operator and station using the cellular network alarm. recorded on a medium from which average 10-12 second transmission the information can be retrieved. time.Product is UL 60 second transmission time). Record and display rate of subsequent Not slower than one every 10 Not applicable,this is a requirement Not applicable,this is a requirement alarms at supervising station. additional seconds. for Alarm Receiving equipment. for Alarm Receiving equipment. Signal repetition,parity check,or The proprietary communication The proprietary communication some equivalent means of error protocol used by DSC in 3G3070-CF protocol used by DSC in T-Link Signal error detection and correction. detection and correction must be communicator is including checksum TL300/TL300CF communicator is • used. verification and synchronization of including checksum verification and sequence synchronization of sequence. No need for prioritization of paths. Not applicable for single technology Not applicable for single technology Path sequence priority. The requirement is that both paths type of communicators. type of communicators. are equivalent. When a redundant path is required, the alternate path must be provided Not applicable for single technology Not applicable for single technology Carrier diversify. by a public communication service type of communicators. type of communicators. provider different from the primary path where available. When the supervising station does not regularly communicate The throughput probability is ensured The throughput probability is with the transmitter at least once by the periodic heartbeat transmission ensured by the periodic heartbeat every 200 seconds,then the Throughput probability. (end to end communication).The transmission(end to end throughput probability of the alarm heartbeat rate is once every 97 communication).The heartbeat rate transmission must be at least seconds. is once every 10 seconds. 90%in 90 seconds,99%in 180 seconds,99.999%in 450 seconds. If a transmitter shares a Every T-Link TL300/TL300CF transmission or communication Every 3G3070-CF installed at the installed at the protected premises Unique premises identifier. channel with other transmitters, protected premises is uniquely is uniquely identified by an Account it must have a unique transmitter identified by an Account Code. Code. identifier. • 11 D B D Criteria NFPA72 2010 Edition 3G3O7O-CF T-Link TL3OO/TL3O0CF • Requirements Compliance Compliance Internet Service Provider can schedule maintenance work that From time to time,there may be Network operators can schedule can possibly disrupt the service Unique flaws unique flaws in a communication maintenance work that can possibly availability at certain times.Use system.Unique requirements must disrupt the service availability at reliable ISP providers with back-up ) i t m be written for these unique flaws certain times. servers and proper routers capable to prevent denial of service attacks, ,� : R 4 e�`%'^; ?^kr'tkY,i;'wFv&y-'«u'mv. eel'.4 he, ,kk�e+.z'/, spoofing,etc. -fR+*u MJ",;25* t,<. The broadband connection at the 3G3070-CF can only be used for Fire protected premises can be shared. If the communication methodology and Burglary alarm transmissions(no The data used for alarm messages is shared with any other usage,all is very small so the bandwidth is calls or any other application possible Signal priority. alarm transmissions must preempt with this device).The HSPA(3G) not affected by the traffic incurred and take precedence over any for sending alarms/supervisory or other usage.Alarm signals take technology presents a better usage trouble signals to the supervising precedence over supervisory signals, of the network resources in terms of station.This is an installation specific delivering the data. requirement and it is not influenced by the equipment. If the transmitter is sharing on-premises communications The Modem/Hub or Router used equipment,the shared equipment Not applicable,the 3G3070-CF Sharing communications equipment on must be listed for the purpose connects dir ectly to the Cellular for the communication channel at premises. (otherwise the transmitter must Network. the protected premises shall be be installed ahead of the unlisted UL60950 Listed(ITE Equipment). equipment). • y � a , „„,sit:... ''''''' ._ „:0:.,i,,i,,,,i....„;_:,,,,,,,,,,..,.. ,,,,:,.., , 1 / -. •M a#h�"� `Ong fts"1"Leel , ' Illtir' ' , J - • 1 j� J � rew. 5 r fY. ,a9 ,..... „., "a"P'' {v� yYi _ : y10 n ..y6-Nr..r, .m q z u . Clarifications on NFPA72 2010 Edition verbiage • Communication ethods coveredunder ecti26.6.3 The requirements for general communication methods in Section 26.6.3.1 cover all communications methods between the protected premises and the supervising station that differ from DACT,Two-Way Radio and One-Way Private Radio Equipment.Equipment that meets the performance requirements of this section are permitted as suitable communications methods. The specific requirements for general communications are also detailed in the table(see pages 10-12).This table defines that annunciations on the degradation and restoration of a communications path must occur within five (5) minutes(if a single communication technology is used). It also defines the fact that equipment conforming to 26.6.3.1 must only provide a redundant path (multiple communications technologies) if the communication failure on a single path cannot be annunciated within five(5)minutes at the supervising station. Sections 26.6.3.2 and 26.6.3.3 define requirements for specific communication methods identified as DACTS or Two-Way Radio and One-Way Private Radio Equipment.These requirements are not applicable to other transmission technologies like the ones used by 3G3070-CF or T-Link TL300/TL300CF because these products are not using dial up connections and also are not using private radio networks as means for communication with supervising stations. Appendix B: UL Listing Guide _\T MINE MI TIFICATIOMC el RFC TORY UOXX.54019 Control Unit Accessories,System a,nc • Control Unit Accessories,System Geer,nnrei mfnrmannn for control rind Accessories wVrm DIGITAL SECURITY CONTROLS,DIY OF TYCO SAFETY PRODUCTS CANADA LTD 59019 95 OR OGELAND AVE TORONTO,ON M6A 1Y7 CANADA End of lino asters,Nadel(s)EOLR-1,EOLR-2,ROLE-3 Fire alarm communicator for central station mimics fire alarm-mmmerclel:Ethernet/Internet communicator(Other Transmission Technologies)slueallna devices,Model(s)T-Link TL250,T-Link TL300,T-Link R300 CF,suitable for use as a single communications technology (no need for two phone lines)when supervision heartbeat Is enabled and window of supervision at supervising station Is set for 5 minutes,Also suitable for use as a multiple communicatIons technologies when used In conjunction wen another type of communicator(for example a back-up dialer(PACT)over the telephone line).In Oils configuration the two communication methods used shall supervise each other and(allure of each channel shall be annunciated at the supervising station within 29h(c). Fire alarm communicator for central statIon service lire alarm-commercial:RF communicator(GSM-GRAS network/Other Transmission Technologies)signaling Seldom,Model(s)G53055-1 CF.3G3070-CF suitable for use as a single communications technology(no need for two phone lines)when supervision heartbeat is enabled and window of supervision at supervising station Is set for 5 minutes.Also suitable for use as a multiple communications technologies when used In nnjunceen with another type of communicator(for example back-up to a dialer(DACR)over the phone line).In this configuration the two cammcniraonn methods used shall supervise each other and failure of each channel shall he annunciated at the supervising station within 29h(c). (c)-Far use with separately Listed compatible control unite with integral or Listed remote DACT or as a standalone/sok communicator(no need for two phone lines)as indicated In the Installation instructions. laeLJoiligal On 2011-12-23 fjgpvtinnat prior chic near 1112111.011192 pane Tnn e1 2012 UL LLC When the UL Leaf Mark hi on the product.or when the word'Environment"Is Included In the EL Mark,please search the(IL Environment detxhnsr for additional information regarding this products certification. The appearance of a company's name or product In this database does not In melt assure that products so identified have been manufactured under Urs Follow-Up Service.Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service.Always look for the Mark an the product, UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions:1.The Guide Information,Designs and/or Listings(files)must be presented In their entirety and Ina non-misleading manor,without any manipulation of the data(or drawings).2.The statement'Repented from the Online Certia®tians Directory with permission from UL'must appear adjacent to tie extracted materiel.In addition,the reprinted material must Include a copyeght notice in the following format:"N 2012 UL LLC. Approvals: 3G3070-CF NYC Fire Department Certificate of Approval 416083;363070-CF CSFM Listing No.7300-1273:134:T-Link TL300111.3000F CSFM Listing No.7300-1273:135 13 DSG e•�.#h , ' ",, 4n `�An,z ,� t. ��2 I. a 0 *()te arnr 5 2 x f'"' r as« <. a • �y la KIty„,,` ' S"fR�Y( 9. �4,w.t.'gJ. .yy Z''i 1r YM. R Q `�.u*ix�s� f x A'b:x �.,r,€: �+ , .a mil' :. 4, . + d s ' C$17`Y�.ewn� r r• .A t-x° yyfl x a ,� s �. xr ' �i �t3f B'w k ' Y .c. * 'O+ AyYY yam_'' x s '_ a 0 0 a t:,r� ' t > € ^ _ F' :§ , .+. v `a 'pia? �Y�h ll ^s.w 1- ') a - a) O L (n �.rs. � 3" »"yF• y a'# °3�'z'-' ¢ i.,}},y Fq at .9+•''�'r Q) .F� n� as W x1 c `fir 4 a . °,T. , ^ fi '• - U) O EY U a O fi � 0 • �c Exa1 � ma I N OD`� (a) co Q/� t�"tr s T r or•s zv �^h. t•� x § � i xai o O W ' ' ^,„y N , " ,4,4 4 s a S+a ,, ti"bb i a - +_� �— V �/) a 3.y9„ei 4 r � 5 - C, " ,S x' C 'W,+$s _„a ' i O v V,#x, , " �"e ' t- #":x Zr ;fir,� , ,, .— (..)� 0 0+ D s e r f <? x, o 'g8':J`X # 'a. 4•u 4/ n t' § x § V 0 (I) ? x , �3 r ,,r �' ", 5 . co (�D C co s a . * M s Fr r 9 O o '' ?�$ '' 0. t a i''t' .y a. I!) ✓ $� f*y .. 3 "49 } n °v ° E ,— in E O O ' ,z` t w F< ,.. �. • 0 +� i r � ._ . exss .%' t' >x r...?Ys _. *td,, , ti z 'S IL O r w O Cl- • 0 00HzDE LOONNd •- • itSILENT a 5496 Intelligent " KNIGHT Power Module by Honeywell A dynamic combination of power and intelligence for your notification expansion needs. The Model 5496 Intelligent Power Module by Silent Knight is the most-powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®, Gentex®, Faraday, AMSECO and Wheelock®—what you need to drive power-hungry components like ADA notification appliances. The 5496's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. For the most sophisticated and cost-effective notification power supply available, you need Model 5496. Call Silent Knight today for more information at 1-800-328-0103. " Model 5496 • 3 amps per output circuit Intelligent Power Module • Ground fault detector The model 5496 is a 6 amp notification • Communicates to the FACP via 4- I power expander that provides its own wire SBUS (wire runs up to 6000 ft) AC power connection, battery charging • AC loss delay option shuts off power circuit, and backup battery for use with to non-essential high-current fire and security controls such as the accessories like magnetic door • • IntelliKnight Model 5808 Fire Control holders /Communicator. The 5496 is the cost- Lightweight design adds to ease of • effective solution for powering '`-- installation and reduces shipping notification appliances required by the costs Americans with Disabilities Act(ADA). . UL 864,1481 & 1971 listed The 5496 has built-in ANSI cadence pattern,which can upgrade older ANSI Cadence pattern outp• ut control panels that lack cadence capability built-in capability. The Output circuits can be Specifications programmed as Notification Appliance AC Input 120 VAC at 2.7 A K tgir Circuits, or as Auxiliary Power L (configurable for, constant, resettable, Output: 24 VDC at 6 amps or door holder power). Current: Model 5496 Intelligent Features Standby 40 mA Power Module • UL Listed for 6 amps of notification Alarm 160 mA Ambient Temp.: 32°to 120° F power Notification/Aux. 0°to 49°C • Power supply's advanced switch Power circuits: 4 mode design reduces damaging Dimensions: 12.25"W x 16"H x heat and manages power up to 50% Output 3"D(30.88 cm W configuration: 2 Class A(Style Z) x 40.64 cm H x more efficiently than other systems 4 Class B (Style Y) 7.62 D cm) • Built-in synchronization for (1 Class A& appliances from AMSECO, Gentex®, 2 Class B) Approvals: UL Faraday, System Sensors, and Amps per CSFM Wheelock® output circuit: 3.0 (6.0 amps total) MEA 429-92-E vol.XIV • 24 VDC filtered output voltage Notification • Four power-limited notification circuit output: 20.4 to 27.3 VDC Compatible FACPs outputs; 2 Class A or 4 Class B, or 1 @ 3.0 amps each, • Class A and 2 Class B 4.7k EOL resistor IntelliKnight 5700 • • NACs are programmable as required on each • IntelliKnight 5808 Notification Appliance Circuits, or as Class B circuit • ▪ IntelliKnight 5820XL auxiliary power to be used as Battery charging constant, resettable, or door holder capacity: 35.0 AH power Firepower 5496 • Distributed Power Module Engineering Specifications The contractor shall supply a power module compatible with the Silent Knight FACP. The power module must have 6.0 amps of output power. The power module shall connect to the main FACP via an RS 485 system bus (SBUS). The Outputs shall be programmable as Notification Appliance Circuits, or as Auxiliary Power (configurable for, constant, resettable, or door holder power). The power module shall have four separate outputs. The power module RS 485 bus shall be optically isolated providing ground loop isolation and transient protection. 4 Outputs Programmable as Notification Appliance Circuits, or as Auxiliary Power • I Output 1 . SBUS Communication To a Compatible Output 2 . Silent Knight FACP Output 3 41111111 Output 4 , Auxiliary Power Can Be Programmed To Be Constant, Resettable, or Door Holder Power SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA KNIGHT to keep our product information up-to-date and accurate.We cannot cover • all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information, contact FORM#350387 Rev 0©2010 Honeywell International Inc. by Honeywell Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800)328-0103, Fax: (203)484-7118.www.silentknight.com Honeywell KILENT MGHT Honeywell Silent Knight EVS-LOC�^ r MON MOO Local Operator Console The EVS-LOC local operator console is a powerful addition to any = = emergency voice system for mass notification purposes.The console C is a combination supervised remote microphone and annunciator which is compatible with the EVS-Series Emergency Voice System and meets UL requirements for a local operator console(LOC). The EVS-LOC provides an interface to the 6820EVS Emergency >EVS-LOC Voice System.It has a supervised on-board microphone for live annunciation,providing 40 programmable LED communications and its annunciator is capable of performing complete outputs and eight supervised dry contact inputs. operation of the fire alarm system,including silencing and resetting. You can use up to eight 5880 modules on one It has a large 4x40 LCD backlit screen with up to 160 available EVS-LOC control panel for maximum flexibility. characters,providing ample space for messaging.The EVS- is compact size enables it to be mounted inside LOC also has four programmable buttons which can be used to the EVS LOC,or in an accessory cabinet. minimize time spent executing complex or routine tasks. About Silent Knight's emergency voice system: The 6820EVS is a fire and emergency voice 111 The console's emergency communication system operations includes communication system conveniently integrated an on-board supervised microphone,and all call and non-active call and housed in one panel,and meets buttons that can quickly select all active or all non-active output groups, the requirements for mass notification The system also lets you select an EVS message as a priority over fire. as described in UL 2572. The EVS-CE4 is a useful addition to an EVS-LOC application.It COMPATIBILITY adds four audio circuits to the EVS-50W,EVS-100W or EVS- 6820EVS:Addressable fire alarm control panel 125W,mappable to 32 buttons controlling selected output with an emergency mass notification system,up to groups.It is very useful for extended coverage and requires no 1,110 addressable points,a large 160 character 4 additional space as it mounts inside the amplifier cabinet. x 40 display,and four programmable buttons that can be programmed for routine or complex tasks The 5880 LED/l0 module can also be used with an EVS-LOC application. Note: It can also be used with existing 5820XL-EVS The module provides an effective means to customize your remote installations FEATURES & BENEFITS • Provides additional • Makes access to the • Up to four EYSLLOCs • For added flexibility,it • Up to 32 mappable communications and communication can be added to a can also accept speaker circuits can be control options that system easier when compatible emergency programmable trigger connected on the are also available in immediate and timely voice system for a inputs from external EIS-L€3C:using a the 6820EVS primary communications are total of five command source,such as a combination of the panel essential units.This provides Monaco'system,to EVS-50W,EVS-100W • Useful for extending • The optional VIP-TR additional control either the RVM or or EVS-125W options which are Silent Knight's 5880. amplifiers.This is system access to trim ring is useful for additional areas of a creating a visual critical during Up to eight inputs are useful for extended • building or mass appealing interface emergency events available on the 5880 module. reach during times notification network between the panel and when the 6820EVS when urgent mounting wall panel is not within emergency easy reach. communication is required. EVS-LOC Technical Specifications • EMERGENCY VOICE SYSTEM EXAMPLE r For a complete listing of all compliance approvals and °NYMn certifications,please visit 1npu1Ya01i o—tlav"m. www.silentknight.com. Microsoft.Windows and - the Windows Logo are + ,. ",,,1„„ ,a„„ ,,,,,,, registered trademarks �G'ma: "°""' Yad"' Z.Z." """' ,wraw or trademarks of 1�t' I I "+ Microsoft Corporation. ,.. 's y.;,� Silent Knight°and "5"'" `"on .L°'°°`�g. 1°"'"' Honeywell*are registered trademarks of Honeywell International,Inc. _ This document is not •+-mom• intended to be used far • »: N. NoltlraNONTw ......- installation purposes.We 0 et E t, .-,._ t try to keep our product a WA PPP. ...Cs s 0 5". information up-to '— — — — N. .,_,r ..J 5: ' r date and accurate.We „,,,•„,„rs„ ;._�...� cannot cover all specific °c'""a°" Sys. all applications or anticipate ,,. ,.a« .., all requirements.All (MI4 a,.,,�� PPP WO ��°°�^ specifications are subject to change without notice. SPECIFICATIONS ORDERING INFORMATION For Technical Support, call 800-446-6444. EVS-LOC:Local Operators Console PHYSICAL Overall Dimensions:20"W x 26.5"H x 5.05"D ACCESSORIES (50.75 W x 67.3 H x 12.8D cm) EVS-SW24:24 switch expander Color:Red VIP-TR:panel trim ring for flush mounting • ENVIRONMENTAL 5880:LED/10 module EVS-CE4:4 speaker circuit expander Operating Temperature:32EE-120EfF(OM- 49EC) AGENCY LISTINGS AND APPROVALS Humidity:10%-930/0 non-condensing UL 864 and UL 2572 ELECTRICAL Meets the requirements for NFPA 72 Local Protective Signaling Systems&Emergency Standby Current:100mA(6860+RVM+SW-24) Communication Systems Alarm Current:150mA(6860+RVM+SW-24) CSFM approved 7165-0559:0500 Voice Integration Wiring: FDNY COA(pending) Six conductor Two voice bus INSTALLATION Four SBUS The EVS-LOC can be surface or flush mounted. 7 For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com • Honeywell Silent Knight Honeywell 12 Clintonville Road �w� Northford,CT 06472 MI SILENT Doc 3516311Rev A110/17 lila KNIGHT 800-328-0103 4 2017 Honeywell InternationaLInc. li WIN a 0anERIE S S •Add ressable Photoelectric Smoke Detectors The Silent Knight° SK-PHOTO-W Series feature a modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector ,' is constructed for exceptional installation and maintenance efficiency. _ ' The SK-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics,and are direct replacements for the SK-PHOTO Series detectors.A new modern,sleek,contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards.The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software.Sensitivity is continuously monitored and reported to the panel.Point ID capability allows each detector's address to be set with rotary,decimal address switches,providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level.Dual electronic thermistors add 135°F(57°C)fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DNR Series duct detector •housings. FEATURES AND BENEFITS • Designed to meet UL 1268 7th Edition steady red in Alarm • Sealed against back pressure • Sleek and stylish contemporary design • Integral communications and built-in • Plugs into separate base for ease of • Stable communication technique with device-type identification installation and maintenance noise immunity • Remote test feature from the panel • Expanded color options • Addressable by device • Built-in functional test switch activated by • SEMS screws forwiring of the separate base • Rotary,decimal addressing(Refer to the external magnet • Optional remote,single-gang LED Silent Knight panel manuals for device • Walk test with address display(an address accessory capacity) of 121 will blink the detector LED 12- • Optional sounder,relay,and isolator bases • Two-wire SLC connection (pause)-1) • LEDs blink every time the unit is polled • Low standby current • 360°-field viewing angle of the visual alarm • Built-in tamper-resistant feature indicators(two bi-color LEDs);LEDs blink • Designed for direct-surface or electrical- Honeywell green in Normal condition and turn on box mounting Honeywell aSILENT' KNIGHT INSTALLATION B200SR-LF-WH:White,Low Frequency Intelligent sounder base The SK-PHOTO-W Series plug-in intelligent thermal detectors use a for retrofit applications separate base to simplify installation,service,and maintenance. B200SR-LF-IV:Ivory,Low Frequency Intelligent sounder base for •Installation instructions are shipped with each detector, retrofit applications Mount base(all base types)on an electrical backbox which is at B224RB-WH:White,plug-in System Sensor®relay base least 1.5"(3.81 cm)deep.For a chart of compatible junction boxes, B224RB-IV: Ivory,plug-in System Sensor relay base see SK-61045. B224B1-WH:White,plug-in System Sensor isolator detector base Note:Because of the inherent supervision provided bythe SLC loop, end-of-line resistors are not required.Wiring"T-taps'or branches 6224B1-IV: Ivory,plug-in System Sensor isolator detector base are permitted for Style 4(Class`B")wiring. ACCESSORIES Note:When using relay or sounder bases,consult the SK-ISO TR300:White,replacement flange for B210LP or B300-6 bases installation sheet 156 3627 for device limitations between isolator TR300-IV:Ivory,replacement flange for B210LP or B300-6 bases modules and isolator bases. RA100Z(A):Remote 3—32 VDC LED annunciator,mounts to a U.S. OPERATION single-gang electrical box,for use with B501 and B300-6 bases Each SK-PHOTO-W Series detector uses one of the panel's addresses only (total limit is panel dependent)on the Signaling Line Circuit(SLC).It M02-04-00:Test magnet responds to regular polls from the control panel and reports its type and the status.If it receives a test command from the panel(or a local M02-09-00:Test magnet with telescoping handle magnet test),it stimulates its electronics and reports an alarm.It blinks CK300:White,detector color kit,pack of 10 its LEDs when polled and turns the LEDs on when commanded by the CK300-IV:Ivory,detector color kit,pack of 10 panel.The SK-PHOTO-W Series offers features and performance that CK300-BL:Black,detector color kit,pack of 10 represent the latest in smoke detector technology. PRODUCT LINE INFORMATION Note:"-IV"suffix indicates ivory color. •SK-PHOTO-W:White,low-profile photoelectric sensor SK-PHOTO-T-W:White,same as SK-PHOTO-W but includes a built-in 135°F(57°C)fixed-temperature thermal device SK-PHOTO-R-W:White,low-profile intelligent photoelectric sensor, remote test capable,for use with DNR/DNRW B300-6:White,standard flanged low-profile mounting base B300-6-BP:Bulk pack of B300-6,package contains 10 B300-6-IV:Ivory,standard flanged low-profile mounting base B501-WHITE:White,standard European flangeless mounting base B501-BL:Black,standard European flangeless mounting base B501-IV:Ivory,standard European flangeless mounting base B501-WHITE-BP:Bulk pack of B501-WHITE,contains 10 B200S-WH:White,Intelligent,programmable sounder base B200S-IV:Ivory,Intelligent,programmable sounder base B200SR-WH:White,Intelligent sounder base for retrofit applications B200SR-IV:Ivory,Intelligent sounder base for retrofit applications B200S-LF-WH:White,Low Frequency Intelligent,programmable sounder base •B200S-LF-IV:Ivory,Low Frequency Intelligent,programmable sounder base Page 2 of 3—351634:B•7/1/2019 ASK-PHOTO-W SERIES TECHNICAL SPECIFICATIONS PHYSICAL/ENVIRONMENTAL DETECTOR SPACING AND • Sensitivity: APPLICATIONS Silent Knight®and System Sensor° 0 Silent Knight recommends spacing are registered trademarks of - UL Applications:0.5/°to 4.0%perfoot Honeywell International,Inc. obscuration. detectors in compliance with NFPA 72.In - ULC Applications:0.5%to3.5%per foot low airflow applications with smooth ceiling, This document is not intended to be obscuration space detectors 30 feet(9.1m).For specific used for installation purposes.We Size:2.0"(5.3 cm)high;base determines information regarding detector spacing, try to keep our product information placement,and special applications refer to up-to-date and accurate.We cannot diameter NFPA 72.A System Smoke Detector cover all specific applications or - B300-6:6.1"(15.6 cm)diameter Application Guide.documentA05-1003,is anticipate all requirements.All - B501:4"(10.2 cm)diameter available at www.systemsensor.com. specifications are subject to change For a complete list of detector bases,see AGENCY LISTINGS AND without notice. SK-61045. APPROVALS Shipping weight 3.4 oz.(95 g) Country of origin:Mexico These listings and approvals apply to the Operating temperature range: modules specified in this document.ln some • SK-PHOTO-W:32°F to 122°F(0°C to 50°C) cases,certain modules or applications may • SK-PHOTO-T-W:32°F to 100°F(0°C to not be listed by certain approval agencies,or 38°C) listing may be in process.Consult factory for • SK-PHOTO-R-W installed in a DNR/DNRW: latest listing status. -4°F to 158°F(-20°C to 70°C) • UL Listed:S6173 UL/ULC Listed Velocity Range:0-4000 ft/ • FM Approved min.(1219.2 m/min.),suitable for • CSFM:7272-0559:0512 installation in ducts • Relative humidity:10%—93%non- condensing Thermal ratings:fixed-temperature set point 135°F(57°C),rate-of-rise detection 15°F(8.3°C)per minute,high temperature heat 190°F(88°C) ELECTRICAL SPECIFICATIONS Voltage range:15-32 volts DC peak Standby current(max.avg.):200pA @ 24 VDC(one communication every 5 seconds with LED enabled) Max current:4.5 mA @ 24 VDC("ON") •Honeywell Silent Knight 12 Clintonville Road (� Northford,CT 06472-1610 Honeywell 203.484.7161 351634 16 107/19 r SILENT wwwsilentknight.com ©2019 HoneymelInternationallnc. KNIGHT SYSTEM �,.$ SENSOR' Select Series Mounting Base Options � 11 System Sensor mounting bases and kits provide a variety 1 /�r of installation options for detectors in any application. —^ Features To meet local code and application requirements, • Bases enable quick and secure detector plug-in System Sensor offers standard 4"and 6"bases,as well as, specialty base designs including relay,isolator,sounder and low • SEMS screws provide easy wiring connection frequency sounder options for Select Series detectors. • Support for 12-24 AWG provides installation flexibility The standard 4"and 6"bases offer a plug-in detector base intended • for use in intelligent systems,with screw terminals provided for power • Multiple base formats meet application requirements (+and-),and remote annunciator connections.Communication • Standard white color with ivory and black options takes place over the power(+and-)lines.The 4"base offers a • UL 268 compliant compact design while the 6"base provides compatibility with a wider range of junction boxes. • Mechanical locking feature restricts removal of attached sensor The Select Series specialty bases support application driven head requirements.The bases employ a separate mounting plate Specialty Base Features that installs on various junction box sizes to eliminate unsightly surface-mount boxes.The mounting plate enables pre-wiring of all • Pre-wired mounting plate simplifies installation connections to speed and simplify installation. • Application driven feature sets Relay bases(B224RB-WH/B224RB-IV)provide one form C contact • Sounder bases both UL 268 and UL 464 compliant relay for control of auxiliary functions,such as door closure and elevator recall.The relay can operate in two different modes(short and long delay).The activation time for the short delay is 60 ms to 100 ms,while the activation time for the long delay is 6 sec to 10 sec. A shunt with pin headers,located on the base PC board,is used to set the delay timing. Isolator bases(B22481-WH/B224B1-IV)allow the Signaling Line Circuit(SLC)loop to operate under fault conditions created from a short circuit preventing an entire communication loop from being disabled.The base isolates the section of the loop containing the short circuit from the remainder of the circuit and automatically • restores when the fault is corrected. Agency Listings The Select Series sounder and low frequency sounder bases • are designed for new and existing dwelling unit applications. SIGNALING *,� They offer maximum flexibility in installation,configuration,and • UL LISTED �! ' "'°ROVE° �1 ) : operation to meet or exceed UL 268 and UL 464 requirements.The • • _ 3062622 4'66'bases.730131653.109 °" Relay 8 Isolator bases:7300-16530126 rConsult your fire alarm control panel manufacturer for compatibility Sousse bases:2133- 65313 with the addressable model of the sounder base. lox-lreg regency bases:7300-16510236 SPD5901-00•04/04/2018•Page 1 Select Series low frequency sounder bases select one of two B501-supported tones of volume(75 or 85 dBA),tone(ANSI are designed to meet the NFPA 72 sleeping (ANSI Temporal 3 or Continuous)through a Temporal 3,ANSI Temporal 4 or March Time) • space requirement to produce a fundamental jumper. and group. In addition,some FACPs will frequency of 520 Hz+/-10%with a square The B200S sounder and LF sounder bases enable custom tone patterns.The B200S wave or its equivalent.Studies show that a (8200S-WH/B200S-IV/B200S-LF-WH/ series sounder bases recognize the System lower frequency,centered around 520 Hz,is B200S-LF-IV)adopt the same address as Sensor synchronization protocol.This the most ideal to wake sleeping occupants, the detector, but use a unique device type enables it to be used as a component of even those with mild to severe hearing loss. on the loop.The Fire Alarm Control Panel the general evacuation signal-along with The B200SR sounder and LF sounder bases (FACP)can use that address to command other System Sensor AV appliances-when (B200SR-WH/B200SR-IV/B200SR-LF-WH/ an individual sounder-or a group of connected to a power supply or FACP output B200SR-LF-IV)are fully compatible with sounders-to activate.The command set capable of generating the System Sensor existing B501 BH-Series sounder base from the FACP can be tailored to multiple synchronization pulses. installations.The device enables users to event-driven tone outputs allowing selection Specifications-Select Series Bases Physical Specifications Diameter 13501-WHITE,B501-IV,6501-BL:4.0"(10.2 cm) B200S-WH.B200S-IV,B200S-LF-WH,B200S-LF-IV,B200SR-WH,B200SR-IV,B200SR-LF-WH,B200SR-LF-IV:6.85" (17.4 cm) B300-6,B300-6-IV:6.1"(155 mm) B224BI-WH,B224BI-IV B224RB-WH,B224RB-IV:6.85"(17.4 cm) Base Height B501-WHITE,B501-IV,B501-BL:0.74°(18.8 mm) (without sensor) B200S-WH,B200S-IV,B200S-LF-WH,B200S-LF-IV, B200SR-WH,B200SR-IV,B200SR-LF-WH, B200SR-LF-IV: 1.6"(4.1 cm) _�B300-6,B300-6-IV:0.76"(19 mm) B224BI-WH,B224BI-IV, B224RB-WH,B224RB-IV: 1.61"(4.1 cm) Weight: B501-WHITE 0.32 lb(145 gm) B200S-WH,B200S-IV,B200SR-WH,B200SR-IV:0.50 lb(227 gm) B200S-LF-WH,B200S-LF-IV,B200SR-LF-WH,B200SR-LF-IV:Weight:0.6 lb(272 gm) "''8300-6,8300-6-IV:0.32 lb(145 gm) • B224RB-WH,B224RB-IV, B224BI-WH,B224BI-IV 0.50 lb(227 gm) Wire Gauge B501-WHITE,B501-IV, B501-BL,B224BI-WH,B224BI-IV,B224RB-WH,B224RB-IV,B300-6,B300-6-IV: 18 AWG(0.823 mm2)to 12 AWG(3.31 mm2) B200S-WH,B200S-IV,B200S-LF-WH,B200S-LF-IV,8200SR-WH,B200SR-IV,B200SR-LF-WH,B200SR-LF-IV: 14 AWG to 12 AWG Temperature Range Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at systemsensor.com Humidity Range 10%to 93%RH non-condensing Electrical Specifications: Electrical Specifications: B501-WHITE,B501-IV,B501-BL(Includes base and detector) B224RB-WH,B22RB-IV Operating Voltage 15 to 32 VDC Operating Voltage 15 to 32 VDC Standby Current 150 pA Standby Current 170 pA max. Set Time Position 1,Short Delay:60 to 100 ms Position 2,Long Delay:6 to 10 sec Electrical Specifications: Reset Time 20 ms max. 6300-6,B300-6-IV Relay 2 coil latching relay Operating Voltage 15 to 32 VDC Characteristics 1 Form C contact Standby Current 170 pA max. ULJULC Rating: CURRENT MAXIMUM LOAD APPLICATION RATING VOLTAGE DESCRIPTION Electrical Specifications: 2 A 25 VAC PF=0.35 Non-coded B224BI-WH,B22BI-IV 3 A 30 VDC Resistive Non-coded Operating Voltage 15 to 32 VDC 2 A 30 VDC Resistive Coded Standby Current 450 pA max. 0.46 A 30 VDC (L/R=20ms) Non-coded Isolation Current 15 mA max 0.7 A 70.7 VAC PF=0.35 Non-coded 0.9 A 125 VDC Resistive Non-coded • 0.5 A 125 VAC PF=0.75 Non-coded 0.3 A 125 VAC PF=0.35 Non-coded SP0S901-00•04/04/2018•Page 2 Electrical Specifications: Electrical Specifications: B200S-WH,B200S-IV B200S-LF-WH,B200S-LF-IV • External Supply Electrical Ratings External Supply Electrical Ratings External Supply 16 to 33 VDC(VFWR) External Supply 16 to 33 VDC(VFWR) Voltage Voltage Standby Current: 500 pA maximum Standby Current: 550 pA maximum VDC Alarm Current: 35 mA maximum(at high volume setting); Alarm Current,High-volume setting 15 mA maximum(at low volume setting) 70 mA maximum @ 33.0 VDC SLC Electrical Ratings 90 mA maximum @ 24.0 VDC SLC Operating 15 to 32 VDC 140 mA maximum 016.0 VDC Voltage: Alarm Current,Low-volume setting SLC Standby 300 pA maximum 15 mA maximum @ 33.0 VDC Current: 20 mA maximum @ 24.0 VDC Sound Output 25 mA maximum©16.0 VDC High Volume: Greater than 85 dBA minimum measured in SLC Electrical Ratings a UL reverberant room at 10 feet,24 Volts(in SLC Operating 15 to 32 VDC continuous tone) Voltage: Low Volume: Greater than 75 dBA minimum measured in SLC Standby 300 pA maximum(base only,refer to a UL reverberant room at 10 feet,24 Volts(in Current: applicable sensor specification) continuous tone) Sound Output High Volume: Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet,24 Volts(in continuous tone) Low Volume: Greater than 75 dBA minimum measured in a UL reverberant room at 10 feet,24 Volts(in continuous tone) Electrical Specifications: Electrical Specifications: B20OSR-WH,B200SR-IV B200SR-LF-WH,B200SR-LF-IV • External Supply Electrical Ratings External Supply Electrical Ratings External Supply 16 to 33 VDC(VFWR) External Supply 16 to 33 VDC(VFWR) Voltage Voltage Standby Current: 500 pA maximum Standby Current: 1 mA maximum VDC Alarm Current: 35 mA maximum Alarm Current 65 mA maximum 0 33.0 VDC SLC Electrical Ratings 90 mA maximum @ 24.0 VDC SLC Operating 15 to 32 VDC 125 mA maximum 016.0 VDC Voltage: SLC Electrical Ratings SLC Standby 300 pA maximum SLC Operating 15 to 32 VDC Current: Voltage: Sound Output Greater than 85 dBA minimum measured in SLC Standby Refer to applicable sensor specification. a UL reverberant room at 10 feet,24 Volts(in Current: continuous tone) Sound Output Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet,24 Volts(in continuous tone) • SPOS901-00•04I04/2018•Page 3 Select Series Junction Box Selection Guide 4" • Single Double 3.5" 4" 4" Square 50 60 70 75 Model Gang Gang Octagonal Octagonal Square with mud ring' mm mm mm mm B501-WHITE,B501-IV, No No Yes No No Yes Yes Yes Yes No B501-BL B200S-WH,B200S-IV, B200S-LF-WH,B200S-LF-IV, B200SR-WH,B200SR-IV, Yes Yes Yes Yes Yes Yes No No No No B200SR-LF-WH, B200SR-LF-IV ~-'-)''B300-6,8300-6-IV Yes No Yes Yes Yes Yes No No No No B224BI-WH,B224BI-IV Yes Yes Yes Yes Yes Yes No No No No B224RB-WH,B224RB-IV Yes Yes Yes Yes Yes Yes No No No No *with 3.0°mud ring Note:Box depth contingent on base and wire size.Refer to National Electric Code or applicable local codes for appropriate recommendations. Ordering Information Model Description White Ivory Black B501-WHITE 8501-IV B501-BL 4°Flangeless mounting base Accessories B501-WHITE-BP - 4"Flangeless mounting base bulk pack, white "—`�B300-6 B300-6-IV — 6'Flanged mounting base RA100Z B300-6-BP 6"Flanged mounting base bulk pack, Remote LED white Annunciator B200S-WH B200S-IV — Intelligent addressable sounder base • B200S-LF-WH B2005-LF-IV Intelligent addressable sounder base, low-frequency B200SR-WH B200SR-IV Standard sounder base(compatible with B501BH series) B200SR-LF-WH B200SR-LF-IV — Low-frequency sounder base(compatible with B501 BH series) CK300-13L B224B1-WH B224BI-IV — Isolator base Color Kit B224RB-WH B224RB-IV Relay base Related Accessories White Ivory Black CK300 CK300-IV CK300-BL Color kit(Includes cover and trim ring) CK300-IR CK300-IR-IV CK300-IR-BL PTIR Color kit(includes cover and trim ring) 411k) TR300 TR300-IV — Trim ring SMB600 Surface mounting kit(flanged),ivory RA100Z — — Remote LED annunciator TR300 M02-04-00 Detector test magnet Trim Ring M02-09-00 Test magnet with telescoping handle 1;" ,, w--1,4 • *T SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 02018System sensor SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 Product epeeicauons subject to change without mice Visit systemsensor corn far current product inMmaisao nclucling the latest versos of this data sheet. W W W.systemsensor.com sPos901-o0•04/04/2018 ----„, S _ H A T.,...w SERIES •Addressable Heat Detectors The Silent Knight° SK-HEAT-W Series heat detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the SK-HEAT-W Series ` *. ideal for both system operation and building `_ design. The series includes a 135°F/57°C fixed-temperature,rate-of-rise,and a 180°F/88°C fixed high-temperature detectors and are direct replacements for the SK-H EAT Series heat detectors.The point ID address,set using rotary decimal switches,provide specific detector locations.These thermal detectors provide effective,intelligent property protection in a variety of applications. • SK-HEAT-W offers 135°Ffixed thermal detection. • SK-HEAT-ROR-W offers 135°F fixed and rate-of-rise thermal detection. • SK-HEAT-HT-W provides fixed high-temperature detection at 190°F. I . FEATURES AND BENEFITS • Designed to meet UL 268 7th Edition • 360°-field viewing angle of the visual alarm • Designed for direct-surface or electrical- • Sleek and stylish contemporary design indicators(two bi-color LEDs);LEDs blink box mounting • Advanced thermal technology for fast green in Normal condition and turn on • Sealed against back pressure response steady red in Alarm • Plugs into separate base for ease of • Fixed temperature model(SK-HEAT-W) • Integral communications and built-in installation and maintenance factory preset to 135°F(57°C) device-type identification • SEMS screws for wiring of the separate base • Rate-of-rise model(SK-HEAT-ROR-W), • Remote test feature from the panel • Optional remote,single-gang LED 15°F(8.3°C)per minute • Built-in functional test switch activated by accessory • High temperature model(SK-HEAT-HT-W) external magnet • Optional sounder,relay,and isolator bases factory preset to 190°F(88°C) • Walk test with address display(an address • Optional flanged surface mounting kit • Addressable by device of 121 will blink the detector LED 12- •• Rotary,decimal addressing(Refer to the (pause)-1) Silent Knight panel manuals for device • Low standby current capacity) • Built-in tamper-resistant feature Honeywell • Two-wire SLC connection • LEDs blink every time the unit is polled SILENT ®KNIGHT APPLICATIONS B200SR-LF-IV:Ivory,Low Frequency Intelligent sounder base for Use thermal detectors for protection of property.For further retrofit applications information,refer to manual 156-6529,Applications Manual for B224RB-WH:White,plug-in System Sensor°relay base •System Smoke Detectors,which provides detailed information on B224RB-IV:Ivory,plug-in System Sensor relay base detector spacing,placement,zoning,wiring,and special applications. B224B1-WH:White,plug-in System Sensor isolator detector base B224BI-IV:Ivory,plug-in System Sensor isolator detector base INSTALLATION The SK-HEAT-W Series plug-in intelligent thermal detectors use a ACCESSORIES separate base to simplify installation,service,and maintenance. TR300:White,replacement flange for B210LP or B300-6 bases Installation instructions are shipped with each detector. TR300-IV:Ivory,replacement flange for B210LP or B300-6 bases Mount base(all base types)on an electrical backbox which is at RA100Z(A):Remote 3-32 VDC LED annunciator,mounts to a U.S. least 1.5'(3.81 cm)deep.For a chart of compatible junction boxes, single-gang electrical box,for use with B501 and B300-6 bases see SK-61045. only Note:Because of the inherent supervision provided bythe SLC loop, M02-04-00:Test magnet end-of-line resistors are not required.Wiring"T-taps"or branches are permitted for Style 4(Class"B")wiring. M02-09-00:Test magnet with telescoping handle Note:When using relay or sounder bases,consult the SK-ISO CK300:White,detector color kit,pack of 10 installation sheet 156-3627 for device limitations between isolator CK300-IV:Ivory,detector color kit,pack of 10 modules and isolator bases. CK300-BL:Black,detector color kit,pack of 10 PRODUCT LINE INFORMATION --�-`SK-HEAT-W:White,low-profile intelligent 135°F fixed thermal sensor SK-HEAT-ROR-W:White,low-profile intelligent rate-of-rise thermal •sensor SK-HEAT-HT-W:White,low-profile intelligent 190°F fixed thermal sensor B300-6:White,standard flanged low-profile mounting base B300-6-BP:Bulk pack of B300-6,package contains 10 B300-6-IV:Ivory,standard flanged tow-profile mounting base B501-WHITE:White,standard European flangeless mounting base B501-BL•Black,standard European flangeless mounting base B501-IV:Ivory,standard European flangeless mounting base 13501-WHITE-BP:Bulk pack of 8501-WHITE,contains 10 B200S-WH:White,Intelligent,programmable sounder base B200S-IV:Ivory,Intelligent,programmable sounder base B200SR-WH:White,Intelligent sounder base for retrofit applications B200SR-IV:Ivory,Intelligent sounder base for retrofit applications B200S-LF-WH:White,Low Frequency Intelligent,programmable sounder base B200S-LF-IV:Ivory, Low Frequency Intelligent,programmable sounder base B200SR-LF-WH:White,Low Frequency Intelligent sounder base • for retrofit applications Page 2 of 3—351637:B•7/1/2019 ASK-HEAT-W SERIES TECHNICAL SPECIFICATIONS PHYSICAL/ENVIRONMENTAL AGENCY LISTINGS AND Size:2.0"(5.3 cm)high;base determines APPROVALS Silent Knight°and System Sensor° •diameter These listings and approvals apply to the are registered trademarks of -B300-6:6.1"(15.6 cm)diameter modules specified in this document.ln some Honeywell International,Inc. -B501:4"(10.2 cm)diameter cases,certain modules or applications may This document is not intended to be not be listed by certain approval agencies,or used for installation purposes.We For a complete list of detector bases,see listing may be in process.Consult factory for SK-61045. try to keep our product information latest listing status. up-to-date and accurate.We cannot Operating temperature range:SK-HEAT-W, • UL Listed:S6228 cover all specific applications or SK-HEAT-60R-W:-4°F to 100°F • FM Approved anticipate all requirements.All (-20°C to 38°C) • CSFM:7270-0559:0511 specifications are subjectto change SK-HEAT-HT-W:-4°Fto 150°F(-20°C to without notice. 66°C) Country of origin:Mexico Detector spacing:UL approved for 50 ft. (15.24 m)center to center;FM approved for 25 x 25 ft.(7.62 x 7.62 m)spacing Relative humidity:10%-93%non- condensing Thermal ratings:Fixed-temperature set point 135°F(57°C),rate-of-rise detection 15°F(8.3°C)per minute,high temperature heat 190°F(88°C) ELECTRICAL SPECIFICATIONS •Voltage range:15-32 volts DC peak Standby current(max.avg.):200uA®24 VDC(one communication every 5 seconds with LED enabled) LED current(max.):4.5mA @ 24 VDC("ON") Honeywell Silent Knight • 12ClintonvllleRoad Narthford,CT 06472-1610 ■u■oneywell 203 484.7161 35837 I s 107/19 it SILENT www.silentknto ht.com ©2019-oneywell International Inc. KNIGHT f SYSTEM �,. SENSOR® Select Series Mounting Base �� = , Options „., ! \ ) V System Sensor mounting bases and kits provide a variety / N- • j of installation options for detectors in any application. --.. Features To meet local code and application requirements, • Bases enable quick and secure detector plug-in System Sensor offers standard 4"and 6" bases, as well as, specialty base designs including relay, isolator,sounder and low • SEMS screws provide easy wiring connection frequency sounder options for Select Series detectors. • Support for 12-24 AWG provides installation flexibility The standard 4"and 6"bases offer a plug-in detector base intended • • Multiple base formats meet application requirements for use in intelligent systems,with screw terminals provided for power (+and-), and remote annunciator connections.Communication • Standard white color with ivory and black options takes place over the power(+and-)lines.The 4"base offers a • UL 268 compliant compact design while the 6"base provides compatibility with a wider range of junction boxes. • Mechanical locking feature restricts removal of attached sensor The Select Series specialty bases support application driven head requirements.The bases employ a separate mounting plate Specialty Base Features that installs on various junction box sizes to eliminate unsightly surface-mount boxes.The mounting plate enables pre-wiring of all • Pre-wired mounting plate simplifies installation connections to speed and simplify installation. • Application driven feature sets Relay bases(B224RB-WH/6224RB-IV)provide one form C contact • Sounder bases both UL 268 and UL 464 compliant relay for control of auxiliary functions,such as door closure and elevator recall.The relay can operate in two different modes(short and long delay).The activation time for the short delay is 60 ms to 100 ms,while the activation time for the long delay is 6 sec to 10 sec. A shunt with pin headers, located on the base PC board, is used to set the delay timing. Isolator bases(B224B1-WH/B224B1-IV)allow the Signaling Line Circuit(SLC)loop to operate under fault conditions created from a short circuit preventing an entire communication loop from being disabled.The base isolates the section of the loop containing the short circuit from the remainder of the circuit and automatically restores when the fault is corrected. Agency Listings The Select Series sounder and low frequency sounder bases are designed for new and existing dwelling unit applications. SIGNALING 40„ They offer maximum flexibility in installation,configuration,and • UL ' operation to meet or exceed UL 268 and UL 464 requirements.The awowraa:n '- .-I LISTS 3062622 4'8 6'b0ses:7300-16530109 5911 Relay 3Isoalwbasa'.30016530125 tConsult your fire alarm control panel manufacturer for compatibility Sounder bawl:71351653.0212 with the addressable model of the sounder base. Low-bepue,cy bases 7300-1653:0238 SPE/8901-00•04/04/2018•Page 1 Select Series low frequency sounder bases select one of two B501-supported tones of volume(75 or 85 dBA),tone(ANSI are designed to meet the NFPA 72 sleeping (ANSI Temporal 3 or Continuous)through a Temporal 3,ANSI Temporal 4 or March Time) • space requirement to produce a fundamental jumper, and group. In addition,some FACPs will frequency of 520 Hz+/-10%with a square The B200S sounder and LF sounder bases enable custom tone patterns.The B200S wave or its equivalent.Studies show that a (B200S-WH/B200S-IV/B200S-LF-WH/ series sounder bases recognize the System lower frequency,centered around 520 Hz,is B200S-LF-IV)adopt the same address as Sensor synchronization protocol.This the most ideal to wake sleeping occupants, the detector,but use a unique device type enables it to be used as a component of even those with mild to severe hearing loss. on the loop.The Fire Alarm Control Panel the general evacuation signal-along with The B200SR sounder and LF sounder bases (FACP)can use that address to command other System Sensor AV appliances-when (B200SR-WH/B200SR-IV/B200SR-LF-WH/ an individual sounder-or a group of connected to a power supply or FACP output B200SR-LF-IV)are fully compatible with sounders-to activate.The command set capable of generating the System Sensor existing B501 BH-Series sounder base from the FACP can be tailored to multiple synchronization pulses. installations.The device enables users to event-driven tone outputs allowing selection Specifications -Select Series Bases Physical Specifications Diameter B501-WHITE,B501-IV,8501-BL:4.0"(10.2 cm) B200S-WH,B200S-IV,B200S-LF-WH,B200S-LF-IV,B200SR-WH,B200SR-IV,B200SR-LF-WH,B200SR-LF-IV:6,85' (17.4 cm) ``�B300-6,8300-6-IV:6.1"(155 mm) 8224BI-WH,B224BI-IV,B224RB-WH, B224RB-IV:6.85"(17.4 cm) Base Height B501-WHITE,B501-IV,8501-BL:0.74"(18.8 mm) (without sensor) B200S-WH,B200S-IV,B200S-LF-WH,B200S-LF-IV,B200SR-WH,B200SR-IV,B200SR-LF-WH,B200SR-LF-IV: 1.6"(4.1 cm) - ' B300-6,B300-6-IV:0.76"(19 mm) B224BI-WH,B224BI-IV,B224RB-WH, B224RB-IV: 1.61"(4.1 cm) Weight: 8501-WHITE 0.32 lb(145 gm) B200S-WH,B200S-IV,B200SR-WH,B200SR-IV:0.50 lb(227 gm) B200S-LF-WH,B200S-LF-IV,B200SR-LF-WH,B200SR-LF-IV:Weight:0.6 lb(272 gm) '`).B300-6,B300-6-IV:0.32 lb(145 gm) • B224RB-WH,B224RB-IV,B224BI-WH,B224BI-IV 0.50 lb(227 gm) Wire Gauge B501-WHITE,6501-IV,13501-BL,B224BI-WH,B22413I-IV,B224RB-WH,B224RB-IV,B300-6,B300-6-IV: 18 AWG(0.823 mm2)to 12 AWG(3.31 mm2) B200S-WH,B200S-IV,B200S-LF-WH,B200S-LF-IV,B200SR-WH,B200SR-IV,B200SR-LF-WH,B200SR-LF-IV: 14 AWG to 12 AWG Temperature Range Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at systemsensor.com Humidity Range 10%to 93%RH non-condensing Electrical Specifications: Electrical Specifications: B501-WHITE,B501-IV,B501-BL(Includes base and detector) B224RB-WH,B22RB-IV Operating Voltage 15 to 32 VDC Operating Voltage 15 to 32 VDC Standby Current 150 pA Standby Current 170 pA max. Set Time Position 1,Short Delay:60 to 100 ms Position 2, Long Delay:6 to 10 sec Electrical Specifications: Reset Time 20 ms max. 6300-0,B300-6-IV Relay 2 coil latching relay Operating Voltage 15 to 32 VDC Characteristics 1 Form C contact Standby Current 170 pA max. UL/ULC Rating: CURRENT MAXIMUM LOAD APPLICATION RATING VOLTAGE DESCRIPTION Electrical Specifications: 2 A 25 VAC PF=0.35 Non-coded 822413I-WH,B2281-IV 3 A 30 VDC Resistive Non-coded Operating Voltage 15 to 32 VDC 2 A 30 VDC Resistive Coded Standby Current 450 pA max. 0.46 A 30 VDC (L/R=20ms) Non-coded Isolation Current 15 mA max 0.7 A 70.7 VAC PF=0.35 Non-coded 0.9 A 125 VDC Resistive Non-coded • 0.5 A 125 VAC PF=0.75 Non-coded 0.3 A 125 VAC PF=0.35 Non-coded SPDs901-00.04/04/201 B•Page 2 Electrical Specifications: Electrical Specifications: B200S-WH,B200S-IV B200S-LF-WH,B200S-LF-IV • External Supply Electrical Ratings External Supply Electrical Ratings External Supply 16 to 33 VDC(VFWR) External Supply 16 to 33 VDC(VFWR) Voltage Voltage Standby Current: 500 pA maximum Standby Current: 550 pA maximum VDC Alarm Current: 35 mA maximum(at high volume setting); Alarm Current,High-volume setting 15 mA maximum(at low volume setting) 70 mA maximum @ 33.0 VDC SLC Electrical Ratings 90 mA maximum 0 24.0 VDC SLC Operating 15 to 32 VDC 140 mA maximum C16.0 VDC Voltage: Alarm Current,Low-volume setting SLC Standby 300 pA maximum 15 mA maximum®33.0 VDC Current: 20 mA maximum @ 24.0 VDC Sound Output 25 mA maximum @ 16.0 VDC High Volume: Greater than 85 dBA minimum measured in SLC Electrical Ratings a UL reverberant room at 10 feet,24 Volts(in SLC Operating 15 to 32 VDC continuous tone) Voltage: Low Volume: Greater than 75 dBA minimum measured in SLC Standby 300 pA maximum(base only,refer to a UL reverberant room at 10 feet,24 Volts(in Current: applicable sensor specification) continuous tone) Sound Output High Volume: Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet,24 Volts(in continuous tone) Low Volume: Greater than 75 dBA minimum measured in a UL reverberant room at 10 feet,24 Volts(in continuous tone) Electrical Specifications: Electrical Specifications: B200SR-WH,B200SR-IV B200SR-LF-WH,B200SR-LF-IV • External Supply Electrical Ratings External Supply Electrical Ratings External Supply 16 to 33 VDC(VFWR) External Supply 16 to 33 VDC(VFWR) Voltage Voltage Standby Current: 500 pA maximum Standby Current: 1 mA maximum VDC Alarm Current: 35 mA maximum Alarm Current 65 mA maximum @ 33.0 VDC SLC Electrical Ratings 90 mA maximum @ 24.0 VDC SLC Operating 15 to 32 VDC 125 mA maximum C16.0 VDC Voltage: SLC Electrical Ratings SLC Standby 300 pA maximum SLC Operating 15 to 32 VDC Current: Voltage: Sound Output Greater than 85 dBA minimum measured in SLC Standby Refer to applicable sensor specification. a UL reverberant room at 10 feet,24 Volts(in Current: continuous tone) Sound Output Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet,24 Volts(in continuous tone) • SPDS901-00.O./04/2018•Page 3 Select Series Junction Box Selection Guide 4" • Single Double 3.5" 4" 4" Square 50 60 70 75 Model Gang Gang Octagonal Octagonal Square with mud ring' mm mm mm mm 6501-WHITE,B501-IV, No No Yes No No Yes Yes Yes Yes No B501-BL B200S-WH, B200S-IV, B200S-LF-WH,B200S-LF-IV, B200SR-WH,B200SR-IV, Yes Yes Yes Yes Yes Yes No No No No B200SR-LF-WH, B200SR-LF-IV - ..y B300-6, B300-6-IV Yes No Yes Yes Yes Yes No No No No B224BI-WH,B224BI-IV Yes Yes Yes Yes Yes Yes No No No No B224RB-WH,B224RB-IV Yes Yes Yes Yes Yes Yes No No No No with 3.0"mud ring Note: Box depth contingent on base and wire size.Refer to National Electric Code or applicable local codes for appropriate recommendations. Ordering Information Model Description White Ivory Black B501-WHITE 6501-IV B501-BL 4"Flangeless mounting base Accessories B501-WHITE-BP 4"Flangeless mounting base bulk pack, white _' B300-6 B300-6-IV — 6"Flanged mounting base RA100Z 8300-6-BP - 6"Flanged mounting base bulk pack, Remote LED white Annunciator B200S-WH B200S-IV Intelligent addressable sounder base • B200S-LF-WH B200S-LF-IV Intelligent addressable sounder base, low-frequency B200SR-WH B200SR-IV — Standard sounder base(compatible with B501 BH series) B200SR-LF-WH B200SR-LF-IV — Low-frequency sounder base(compatible with B501BH series) CK300-BL II B224BI-WH B224BI-IV — Isolator base Color Kit B224RB-WH B224RB-IV — Relay base Related Accessories White Ivory Black CK300 CK300-IV CK300-BL Color kit(includes cover and trim ring) CK300-IR CK300-IR-IV CK300-IR-BL PTIR Color kit(includes cover and trim ring) 6) TR300 TR300-IV — Trim ring SMB600 Surface mounting kit(flanged),ivory RA100Z Remote LED annunciator TR300 M02-04-00 Detector test magnet Trim Ring M02-09-00 Test magnet with telescoping handle , :`411 ' :,,..„441, • *� SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2019 System Sensor r Phone:600-SENSOR2•Fax:630-377-6495 Product specifications subject to change©tout notice.Vise systemsensacorn SENSOR for current product inlormation,including the latest versionMfiis datasheet.Ji y��l/ wwwsystemsensoccom SPOS901-00•04/04/2018 Pr • Intelligent Single-ended Reflective Imaging Beam Smoke Detector The OSI-RI-SK delivers rapid installation, trouble-free detection, and a minimalist design for challenging open-area11 11 applications. The OSI-RI-SK intelligent addressable reflector-type linear optical beam smoke detector is "_ uniquely suited for protecting large open areas with high ceilings where spot-type smoke detectors are difficult to install and maintain.Ideal applications are warehouses,malls, The OSI-RI-SKsingle-ended beam smoke detector is aircraft hangers,arenas and concert halls The beam operates primarily on the principle of easy to instal/and adjust.Only the head unit needs to light obscuration using infrared.The OSI-RI-SK detector is a combined transmitter/receiver be wired,and the eyebail"can be aimed without and is compatible with Silent Knight Addressable Fire Alarm Control Panels. adjusting the detector mounting. Fast and Easy Alignment Aligning the imager to the reflector is extremely intuitive,fast,and accurate,thanks to the CMOS imager contained in a movable"eyeball"that can move vertically and horizontally. Four LED arrows help the user find the imager's perfect alignment with the reflector.Once the optimum alignment is found,indicated by all green arrows,the lens is locked with a slide lever.A paintable cover is then placed over the front to secure the lever in locked position. Resistant to Building Movement,Sunlight,and Foreign Object Intrusion The receiver imager automatically tracks the reflector in case of building movement or support structure movement.This allows the OSI-RI-SKto be highly resistant to movement, eliminating the number one cause of false alarms and/or faults with traditional beam detectors. •Optical filtering,high-speed image acquisition and intelligent software algorithms provide the system with highly improved resistance to false alarms from sunlight,reflected sunlight or any other very bright light sources.Advanced smoke imaging techniques allow the detector to avoid false alarms from partial and sudden blockage from foreign object intrusion. Time-saving Automatic Sensitivity Setting Unique in the market,the sensitivity of the detector is selected and set automatically at the optimum sensitivity based on the size of the reflector measured in the field of view. Drift Compensation The detector will adjust its detection thresholds in line with any long-term signal reduction of the beam caused by dust or other contamination of the optical surfaces. Equipped with Built-in Imager Heater The imager ships standard with an internal heating option to prevent condensation on the optical surface.(External power supply required.) FEATURES AND BENEFITS • Combined transmitter/receiver unit • Resistant to building movement;tolerates • Paintable housing/cover • Wide 12°field of view +/-1°movement • Removable plug-in terminal blocks • Fast,easy,and intuitive beam alignment • Resistant to strong light sources;does not • Built-in imager heater indicated by LED directional arrows alarm when saturated by sunlight • Optional reflector heater kit available • 50°horizontal and 20°vertical beam • Resistant to solid object intrusion adjustment • Remote test station capable for electronic •• Long range coverage of 16-328 ft(5-100m) simulated smoke test from ground level s standard;no separate long-range kit • Status LED indicators visible from the front required and bottom Honeywell • Automatic sensitivity threshold level setting • Automatic drift compensationEl SILENT KNIGHT OSI-RI-SK TECHNICAL SPECIFICATIONS PHYSICAL Application Temperature Range:-4°F to 131°F (-20°C to+55°C) • Dimensions(Detector):Height 6"(152.4 mm): Humid(tyRange:Oto95°/orelativehumidity, Silent Knight® is a registered Width 10"(254 mm);Depth 4.5°(114.3 mm) non-condensing trademark of Honeywell Dimensions(Reflector):Height9.06°(230 mm); International Inc. Width 7.87"(200 mm) OPERATIONAL Weight(Installed):2.48 lbs(1.12 kg) This document is not intended to be Weight(Shipping):3.91 lbs(1.77 kg) Protection Range:16 ft to 328 ft(5 m to 100 m) used for installation purposes.We Adjustment Angle:20 degrees vertical,50 Wire Gauge for Terminals:14 AWG(2.08 mm2) degrees horizontal try to keep our product information ELECTRICAL Sensitivity Levels:Level 125%,Level 230%, up-to-date and accurate.We cannot Level 340%,Level 450% cover all specific applications or OSI-RI-SKI- ' Test/Reset Features:Local.alarm test switch, anticipate all requirements.All Operating Voltage Range: local alarm reset switch,Remote test and reset specifications aresubjecttocanh e Nominal:24 VDC switch(compatible with RTS151 and g Minimum:15 VDC RTS151KEY(-A)test stations),OSID-R test filter. without notice. Maximum.32.0 VDC Smoke Detector Spacing:On smooth ceilings, Maximum Standby Current: 30-60 feet between projected beams and not Country of origin: Mexico 13 mA @ 32 VDC more than one-half that spacing between a 14 mA @ 24VDC projected beam and a sidewall.Other spacing 20 mA @ 15 VDC may be used depending on the ceiling height, Maximum Alarm Current(LED on): airflow characteristics,and response 22 mA @ 32 VDC requirements.See NFPA 72. 15mA@24VDC 22 mA @ 15VDC AGENCY LISTINGS 1 Maximum Devices per SLC Loop: UL:S911 The number of OSID-R devices are limited due to FM:PR449231 SLC current draw restrictions.Current draws CSFM:7260-0559:0515 listed above must be considered in coordination with any other devices on a circuit In general,this PRODUCT LINE INFORMATION limits the number of OSID-R detectors to up to 4 detectors per loop on a dedicated circuit on OSI-RI-SK:Intelligent imaging beam smoke •Silent Knight panels.Any non-beam devices, detector including reflector increased distances or higher gauge wiring on OSP-002:Laser alignment tool the circuit will decrease available current and OSP-004:Test filter,10 pack total capacity of OSID-R detectors. RTS151:Remote test station Available panel current RTS151KEY:Test and reset station with key lock, •6700:100ma Normal operating current flush mount •6808:150ma Normal operating current BEAMHKR:Heater kit for the reflector •6820:150ma Normal operating current 6500-MMK:Multi-mount accessoryforceiling or BEAMHKR wall mounting with additional mounting Voltage Range:15 to 32 V adjustment Maximum Current:450 mA Max at 32 V Power Consumption: 7.7W®24V 15W@32V RTS151KEY Voltage Range:10.2 to 32 VDC Current Range:9 mA Min to 11 mA Max ENVIRONMENTAL Operating Temperature:UL-Listed for use from 32°F to 100°F(0°C to 37.8°C). IDHoneywell Silent Knight 12Clintonville Road No Honeywell Northford,CT 06472-1610 203.484.7161 SK-61052 I 0 107/20 SILENT www.silentknight.com ©2020 Honeywell International Inc. liaKNIGHT numitimmaim HORN /STROBE/SPEAKER • DAMAGE STOPPERS® , _ 4' 4 4. ' C U� us / i t c• Allolior Amor STI-9705 P STI-9711 Apt tin■ rilliiiii F 11111il 74 . ti KEY FEATURES I _I ir; ali 1 ; General Information IE P` ' i •Offers protection against vandalism and accidental damage. to Am NI. •Simple removal for maintenance. STI-9720 •For use in controlled environment (not intended for outdoor use). •Three year guarantee against breakage in normal use. PRODUCT OVERVIEW Construction - Here are excellent ways to protect strobe units against both vandalism and accidental constructed of tough 9-gauge steel wire. damage. Constructed of tough, 9-gauge steel wire coated with corrosion resistant red •Coated with corrosion resistant or white polyester, these guards can take hard knocks in stride. STI-9705, STI-9708,E'-"— polyester. STI-9711 and STI-9714 wire guards provide maximum protection for System Sensor Installation SpectrAlert®Advance series strobe notification appliances. •Installation is fast and simple with screws and anchors provided. BACKED BY A THREE YEAR GUARANTEE Options As all STI protective covers, these guards are backed by a three year guarantee against • STI-97 STI-9714 STI-97os -9711 and protect SpectrAlert breakage in normal use. Installation and servicing is easy with all screws and anchors strobe units. provided. This Stopper is highly recommended for areas where abuse is severe or it is • STI-97i7 and STI-9720 fit over imperative that strobe units continue to operate. STI-9717 and STI-9720 fit over System System Sensor notification • Sensor notification appliances SP2R1224MC and SP2W1224MC. appliances P2R1224MC andSP2w1224MC. For more information,call 248-673-9898 or visit www.sti-usa.com. 70 Safety Technology International Horn/Strobe/Speaker Damage Stoppers® Dimensions and Technical Information • MODELS AVAILABLE APPROVALS & WARRANTY STI-9705 Damage Stopper,Flush Mount-White TESTING L/ STI-9705-R Damage Stopper,Flush Mount-Red ySTI-9708 Damage Stopper,Surface Mount-White STI-9705,STI-9708,STI-9711 and STI-9714 have been tested and STI-9708-R Damage Stopper,Surface Mount-Red approved or listed by: STI-9711 Damage Stopper,Flush Mount-White -Underwriter Laboratories and Canadian UL File S7025 STI-9714 Damage Stopper,Surface Mount-White WARRANTY STI-9717 Speaker/Strobe Damage Stopper-Flush Mount Three year guarantee against breakage in normal use. (not UL Listed) STI-9720 Speaker/Strobe Damage Stopper-Surface Mount Light De-Rating Factor,.„..--- Light Loss (not UL Listed) STI-9705 and STI-970 % System Sensor (SR,SW, SW-ALERT, SW-CLR-ALERT, SRK, 13% MODEL HEIGHT WIDTH DEPTH SWK, P2R, P2W, P4R, P4W, CHSR, CHSW, P2RK, P2WK, STI-9705 P4RK, P4WK, SPSR, SPSR-SP, SPSR-PG, SPSW, SPSW- CLR-ALERT, SPSW-SP, SPSW-PG, SPSRV, SPSRV-SP, STI-9705-R 7.40 in.(188mm) 6.15 in.(156mm) 3.39 in.(84mm) SPSRV-PG, SPSWV, SPSWV-SP and SPSWV-PG, SPSWK, STI-9708 SPSRK,SPSW-ALERT) STI-9708-R 7.49 in.(190mm) 6.74 in.(171mm) 6.09 in.(155mm) System Sensor (SRH, SWH, SRHK, SWH-ALERT, SWHK, 0% STI-9711 8.26 in.(210mm) 8.26 in.(210mm) 3.54 in.(90mm) P2RH,P2WH,P4RH, P2RHK,P2WHK,P2RHK-120,SPSRH, SPSRH-SP,SPSRH-PG,SPSWH,SPSWH-SP and SPSWH- STI-9714 8.55 in.(271mm) 8.55 in.(271mm)..__6.23 in.(158mm) PG,SPSRHK) STI-9717 6.1 in.(155mm) 9.3 in.(238mm) 2.4 in.(61mm) ST1-9711 and STI-9714 ST-9720 6.1 in.(155mm) 9.3 in.(238mm) 4.9 in.(125mm) System Sensor (SCR, SCW, SCRK, SCWK, SCW-CLR- 0% ALERT, PC2R, PC2W, PC4R, PC4W, PC2RK, PC2WK, PC4WK, SPSCWV, SPSCR, SPSCR-SP, SPSCR-PG, I■Ittlr�l-h��I■I All I SPSCW, SPSCW-SP, SPSCW-PG, SPSCRV, SPSCRV- LL+�■11I11 ■�f,I■I PG, SPSCWV, SPSCWV-SP and SPSCWV-PG, SPSCWK, I�I.I■ ■IuI di.. SPSCW-CLR-ALERT) 11111 11111 I�I�I 7.40 in. System Sensor(SCRH, SCWH, SCRHK, SCWHK, PC2RH, 0% I�I1pin gum(188mm) PC2WH,PC4RH,PC2RHK,PC2WHK,PC4WHK,SPSCWHV, 1-� gu SPSCRH,SPSCRH-SP, SPSCRH-PG, SPSCWH,SPSCWH- • \---�� \� j, SPSPSCWH-PG,SPSCRVH,SPSCRVH-SP,SPSCRVH-PG, SPSCWHV-SP SPSCWHV-PG,SPSCWHK) 6.15in. �3.69 I�I I■I=I=I■I (15656mm) (86mm) STI-9705 I■I I■I=I=I■I 3.7 In. �3.15 in...4 I 1.63 in. 1=1 IMI�I�IMI (94mm) (80mm) I (41mm) I IMIMIMIMIMI=IUMI 4.9 in. �I.I.I.I-I�� I I (1 1 m) T II'�'�II■ ■I�11 ,I.I I.I■I ST1-9720t t T I /I�I�I�I TOP VIEW 3.1 in. 7.49 in. + (79mm) Ill.I III.I (190mm) MIME II II II II II II II d II II 12l^• f I�I�� J�I�I plum ��_�—\ __�l(31f m)(2.4 in. 61mm) l r:r_�JI i�IiI� �=' �� I STI-9717 6.74 in , 6.09 in. ,I TOP VIEW (171mm) (155mm) 9.3 in.(238mm) )5TI-9708 ,_----_ —ik —_ `' ifillin .��.���.II� �i� /�/,421,"• • �\ egi, �...LIII,IIIIII,IIIIII1. 6.1 in. I1„Alga 8 n. 8.55 in. I \%� ' '. !U0mm(n ) �I (2mm) MilliIIIIIIIlille-Mal ■■■Tt- rl� 1.rl�l r'— 3.54 in.� 6.231 . 22.s' (90mm) (158mm)—� STI-9717 and STI-9720 STI-9717 5T1-9711 FRONT VIEW SIDE VIEW ell , International 2306 Airport Road Tel:248.673 9898 Taylor HouseTel:+44(0)1527 520 999 Safety TechnologyWaterford,Michigan Fax:248-673-124634 Sherwood Road Fax:+44(0)1527 501 999 48327,USA info@sti-usa.com Bromsgrove,Worcestershire info®sti-emea.com www.sti-usa.com B60 3DR,England www.sti-emea.com Printed in U.S.A.,C 1987-2020 Safety Technology International.Inc. Subject to change without notice. 03/20 • 0SILENT ASK-Pull-SA and SK-Pull-DA KNIGHT by Honeywell Intelligent Pull Stations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knights IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight 1 PULL ♦ DOWN Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition ,,,,T • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition ASK-Pull-SA • Key operated test and reset lock using lock plate actuator ' '• Key matches compatible FACP locks R E • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms I PUSH IN guidelines (Section 4.1.3[13]) PULL OOWN� • Meets ADA requirement for 5 lbs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® y. • Reliable analog communications for trouble-free operation a7 • Braille text on station handle SK-Pull-DA • Handle latches in down position and the word Activated Compatibility appears, clearly indicating the station has been pulled The SK-Pull-SA and SK-Pull-DA are compatible • Rotary address switches for fast installation with the following IntelliKnight FACP's: 5600 • • UL Listed, including UL 38, Standard of Manually Actuated 5700 Signaling System 5808 5820XL 5820XL-EVS INTELLIKNIGHT ACCESSORY Model SK-Pull-DAand SK-Pull-SA • Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans,Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. itfbeti . Class W 1 .... ........._...._...._...._...._...._._., � ,,. , ,. i Class Compatible FACP t r Ad® q .e t ti :7 ID 1 a a a a ® a , . t �� i 1 7 Ill3 Tg re . Class Wltlng: - Class a Wiring: WM y®��-.+ - a-,-Qom.... ,.......«... «, ,73�...'.� Wiring SK-Pull-SA& SK-Pull-DA Pull Stations Specifications Electrical Physical Operating Voltage: 15-32 VDC Height: 5.5" (14 cm) Average Operating Current(LED flashing): 300 pA Width:4" (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm2) Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 32°— 120°F (0°C—49°C) Bi-Colored LED: Humidity: 10%—93% non-condensing Blinking Green: Normal Steady Red:Alarm Accessories Switch: Single pole, single throw (SPST) normally open (N/O) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-I/O Surface backbox SILENT This document is not intended to a W try MADE IN AMERICA to keep our product information up-to-datebeusedfor and inst accurate.11ation Wepurposes.cannot cover KNIGHT all specific applications or anticipate all requirements.All specifications are FORM#350135 Rev C • subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800)328-0103, Fax: (203)484-7118. For Technical Support, ©2013 Honeywell International Inc. Please call 800-446-6444. www.silentknight.com SILENT SK-DUCT • KNIGHT Intelligent Air Duct Smoke Detector by Honeywell Detect smoke in air handling systems and air handling equipment with Silent Knight's addressable duct smoke detector The SK-Duct Intelligent air duct smoke detector is used with SK-PhotoR (included)for detecting smoke and products of combustion present in air moving through an HVAC air handling system. When smoke is detected in a duct, the unit communicates the condition to the IntelliKnight control panel. The panel, in turn, depending on programming and wiring, turns off fans, blowers, and other devices. The duct housing allows for mounting of SK-Relay addressable relay module. Now there's even more power and flexibility available to the IntelliKnight family of products! Description The Model SK-Duct Air Duct Smoke Detector utilizes x� � {{ <� � photoelectric technology for �r � +..:xi` �t '� a9u�� s' for the detection of smoke. It I # �„ provides early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial and Industrial applications. The SK-Duct is in a heavydutygraysteel back box with a s� • clear cover. It features a pivoting housing that fits both ' s square and rectangular footprints capable of mounting to ;��,�' r {�" , «r ` _ � a round or rectangular duct. It installs quickly and easily. SK-DUCT The unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4000 feet per minute, Specifications temperatures of-4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). Physical (Rectangular): 14.38 in (37 cm) Length; Features 5in (12.7 cm) Width; 2.5 in (6.6 cm) Depth • Versatile mounting options: square or rectangular (Square): 7.75 in (19.7cm) Length; configuration 9 in (22.9cm) Width; 2.5 in (6.35cm) Depth • New Cover tamper signal Weight: 1.6lb (0.73kg) • LED alarm indication and communication on sensor Environmental head Operating Temperature: -4°F— 158°F • Detects and limits the spread of smoke (-20°C— 70°C) • Rugged steel back box with clear plastic cover Humidity: 0%— 95% (non-condensing) • Easy to clean Air Velocity • Large terminal connection screws 100 to 4000 ft/min (0.5—20.3 m/sec.) • Transparent cover for convenient visual inspection • Patented sampling tube installs from front or back of the Electrical (using SK-Photo or SK-PhotoR) detector with no tools required Operating Voltage: 15-32 VDC • Available space within housing to accommodate Standby Current: 300 pA @ 24 VDC max. • mounting of relay module Alarm Current: 6.5 mA @ 24 VDC max • UL listed (with LED on) Model SK-DUCT Air Duct Smoke Detector • Engineering Specifications The air duct smoke detector shall be a SK-Duct photoelectric duct smoke detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 fUmin to 4000 ft/min (0.5 m/sec to 20.32 m/sec). The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS151KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18AWG wiring. The unit housing shall be capable of mounting a relay module. Ordering Information SK-Duct Intelligent non-relay duct smoke detector M02-04-00 Test Magnet SK-Photo Addressable Photo Detector P48-21-00 Replacement End Cap for Metal SK-PhotoR Addressable Photo Detector with remote test Sampling Tube capability(included with SK-Duct) APA151 Remote annunciator with piezo alarm SK-Relay Addressable Relay Module, must be added if relay function is required, (fits in housing) Important Notes: Accessoriest •The use of either RTS151 TS151KEY requires the • DST1 Metal Sampling Tube Duct Width up to 1' installation of an accessory coil, DCOIL, sold separately. DST1.5 Metal Sampling Tube Duct Widths 1'-2' Please refer to the SK-Duct installation instructions for DST3 Metal Sampling Tube Duct Widths 2'—4' more information DST5 Metal Sampling Tube Duct Widths 4'—8' • The RTS151/RTS151KEY test coil circuit requires an DST10 Metal Sampling Tube Duct Widths 8'— 12' external 24VDC power supply which must be UL listed. DH4000E-1 Weatherproof Enclosure ETX Metal Exhaust Tube Duct width 1' ccessory urren oa•s a RA100Z Remote LED Annunciator DCOIL Duct accessory coil, required if using with . . SK-Photo and not SK-PhotoR (included)with SK-Duct RTS151 Magnetic Remote Test stationmithwii to immomm RTS151KEY Key-Activated Remote Test stationiimomardimi SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA 4101` to keep our product information up-to-date and accurate.We cannot cover KNIGHT all specific applications or anticipate all requirements.All specifications • are subject to change without notice. For more information, contact Silent FORM#350122 Rev D Knight 12 Clintonville Road, Northford, CT 06472-1610 ©2010 Honeywell International Inc. by Honeywell Phone: (800)328-0103, Fax: (203)484-7118. www.silentknight.com Honeywell rs SILENT' KNIGHT SK-RELAY Intelligent Relay Module The SK-RELAY is an addressable relay module for use with Honeywell Silent Knight Series fire alarm control panels(FACPs).The SK-RELAY allows a Silent Knight FACP to switch discrete contacts by code command.The relay contains two isolated sets of Form C contacts,which operate as a f+, DPDT switch.No supervision is provided for the notification appliance circuit. Honeywell The SK-RELAY contacts can be used for virtually any normally open or ® 4'l,trr normally closed application.Each SK-RELAY is programmed with a unique signaling line circuit(SLC)loop address.When an event occurs that controls the SK-RELAY,the relay is triggered by the FACP. INSTALLATION The SK-RELAY mounts directly into a 4"square electrical box.The box must SK-RELAY have a minimum depth of 2-1/8 A surface mount electrical box(System Sensor'PN SMB500)is available from Silent Knight. • FEATURES & BENEFITS • Two sets of Form C • Panel controlled • Polling LED visible contacts status LED that through the cover • Rotary address flashes green in plate switches for fast normal state and is • SEMS screws for easy installation solid red in alarm wiring • Contacts are rated for • Relay programming is • UL Listed a variety of amps(see completely flexible— Specifications) can be mapped to zone conditions • ~ASK-RELAY Technical Specifications For a complete listing of all • compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION www.silentknight.com_ 4.675"H x 4.275'W x 1.4"D SK-RELAY:Relay Module Shipping Weight:6.3 oz(196 g) Microsoft,Windows,and ACCESSORIES. the Windows Logo are registered trademarks ELECTRICAL SMB500:4"Square Surface Mount Electrical Box or trademarks of Operating Voltage:15-32 VDC CB500:Module Barrier Microsoft Corporation. End-of-Line Resistance:Not used Silent Knight°,System SLC Standby&Alarm Current:.255mA max® COMPATIBILITY Sensor°and Honeywell' 24VDC(one communication every 5 sec with LED The SK-RELAY is compatible with the following are registered enabled) Honeywell Silent Knight fire alarm control panels: trademarks of Honeywell 6820:Addressable fire alarm control panel International,Inc. ENVIRONMENTAL 6820EVS:Addressable fire alarm control panel This document is not Operating Temperature:32Eir-120 (0iE- with an emergency mass notification system. intended to be used for 49M) 6808:Addressable fire alarm control panel installation purposes.We Humidity:10%-93%non-condensing try to keep our product 6700:Addressable fire alarm control panel information up-to RELAY CONTACT RATINGS 5700:Addressable fire alarm control panel date and accurate.We 5808:Addressable fire alarm control panel cannot cover all specific 3.0A®30VDC resistive applications or anticipate 0.9A 110VDC resistive 5820XL:Addressable fire alarm control panel all requirements.AU 0.9A 125VAC resistive 5820XL-EVS:Addressable fire alarm control panel specifications are subject with an emergency mass notification system. to change without notice. 0.5A®125VAC inductive(PF=.35) 0.7A®75VAC inductive(PF=.35) For Technical Support, call800-446-6444. • For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com • HoneywellSilent Knight Honeywell 12 Clintonville Road Ho Beyweil Northford,CT 06472 Doc 3501271 Rev GI 11/17 MI SILENT' 800-328-0103 @ 2017 Honeywell International Inc. NW KNIGHT Honeywell SILENT KNIGHT SK-MONITOR Intelligent Monitor Module The SK-MONITOR is an addressable monitor module for use with Honeywell Silent Knight Series fire alarm control panels(FACPs).The SK-MONITOR is intended for use in intelligent,two-wire systems,where individual address of each module is selected using the built-in rotary switches. ` The SK-MONITOR supports Class A supervised or Class B supervised 'ran m. ' i., wiring to the load device.Conventional 4-wire smoke detectors can be , monitored for alarm and trouble conditions. INSTALLATION xar� The SK-MONITOR mounts directly into a 4'square electrical box.The box must have a minimum depth of 2-1/8".A surface mount electrical box (System Sensor'PN SMB500)is available from Silent Knight. SK-MONITOR • FEATURES & BENEFITS • Single contact monitor • Panel controlled • UL Listed • Support for Class A status LED that • Rotary address and Class B wiring flashes green in switches for fast normal state and is installation • Fully supervised solid red in alarm • SEMS screws for easy wiring • SK-MONITOR Technical Specifications Fora complete listing of all III compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. Height:4.5"H x 4"Wx 1.25"D(11.4 X 10.2 X 3cm) SK-MONITOR:Monitor Module Microsoft,Windows,and Shipping Weight:6.3 oz(196 g) the Windows Logo are ACCESSORIES. registered trademarks ELECTRICAL SM B500:4"Square surface mount electrical box or trademarks of Operating Voltage:15-32VDC Microsoft Corporation. Current Draw(LED on):5.0mA max COMPATIBILITY The SK-MONITOR is compatible with the Silent Knight',System e Operating Current(LED flashing):375µA p Sensor`and Honeywell following Honeywell Silent Knight fire alarm registered Standby Current:400µA max @ 24 VDC(one are communication every 5 sec with 47K EOL);550 µA control panels: trademarks of Honeywell 6820:Addressable fire alarm control panel International,Inc. max @ 24 VDC(one communication every 5 sec with EOL<1K) 6820EVS:Addressable fire alarm control panel This document is not 5.5 mA(with LED latched on) with an emergency mass notification system. intended to be used for LED Current:5.5 mA(with LED latched on) 6808:Addressable fire alarm control panel installation purposes.We End-of-Line Resistance:47KS2 6700:Addressable fire alarm control panel try to keep our product information up-to Initiating Device Circuit Wiring Resistance:1,500 5700:Addressable fire alarm control panel date and accurate.We S2 max 5808:Addressable fire alarm control panel cannot cover all specific SLC Loop Resistance:40S max. 5820XL:Addressable fire alarm control panel applications or anticipate all requirements.All ENVIRONMENTAL 5820XL-EVS:Addressable fire alarm control panel specifications are subject with an emergency mass notification system to change without notice. Operating Temperature:32F-12013F(ODIC- 49i1K) For Technical Support, Humidity:10%-93%non-condensing call800-446-6444. • For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com • Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Doc 3501311 RevG 111/17 SILEN 800-328-0103 62017HoneywellIntemationaLInc. ® T' KNIGHT DF-52068:A•1-400 PAM-1 , PAM-2, and PAM-461144FlI'G'.u'I"eALa ms Multi-Voltage Relay Modules • by Honeywell Relays General Air Products&Controls, Inc. PAM-1, PAM-2,and PAM-4 Multi- Voltage Relay Modules are encapsulated multi-voltage :� " - t devices.The PAM-1 relay provides 10.0 Amp Form-C contacts and may be energized by one of three input voltages: 24 VAC, 4fi� )• t#; 24 VDC, or 115 VAC. The PAM-2 relay provides 7.0 Amp Form-C contacts and may be energized by one of two input n „_ voltages: 12 VDC or 24 VDC. The PAM-4 relay provides 10.0 Amp Form-C contacts and may be energized by a wide voltage range from 9 VDC to 40 VDC. s A red LED is provided on both models. When illuminated, it indicates the relay coil is energized. Either model may be mounted by using the double-sided adhe- sive tape, the self-drilling screw, or by placing loosely in a backbox. PAM-1, PAM-2,and PAM-4 Relay Modules are ideal for appli- " cations where remote relays are required for control or status feedback. They are suitable for use with HVAC, temperature PAM-1 control, fire alarm, security, energy management, and lighting control systems. Agency Listings and Approvals Specifications These listings and approvals apply to the modules specified in Power requirements: this document. In some cases,certain modules or applications may not be listed by certain approval agencies, or listing may • PAM-1: 0.015 Amps per position CO 24 VDC, 24 VAC, 115 be in process. Consult factory for latest listing status. • • PAM-2:0.015 Amps per position @ 12 VDC or 24 VDC. • UL Listed: S3403 • MEA:73-92-E,Volume XXI • PAM-4:0.015 Amps per position @ 24 VDC or 12 VDC. • CSFM:7300-1004:101 Relay: UL-recognized SPDT. Contact Rating: Product Line Information • PAM-1: 10.0 A @ 115 VAC, 7.0 A @ 28 VDC, 250uA @ 5 PAM-1: Single SPDT relay with LED, double-sided adhesive VDC. .. tape, mounting screw, 12"(30.48 cm)leads,and six wire nuts. • PAM-2: 7.0 A @ 115 VAC, 7.0 A @ 28 VDC, 250uA @ 5 .PAM-2: Single SPDT relay with LED, double-sided adhesive VDC. tape, mounting screw, 12"(30.48 cm) leads,and six wire nuts. • PAM-4: 10.0 A @ 120 VAC, 7.0 A @ 24 VDC, 250uA @ 5 PAM-4: Single SPDT relay with LED, double-sided adhesive VDC. tape, mounting screw, 12"(30.48 cm) leads,and six wire nuts. Ambient Temperature Range: -58°F to 185°F (-50°C to 85°C). Dimensions: 1.5" (3.81 cm) high x 1.0" (2.54 cm) wide x 0.875" (2.223 cm) deep, with 12" (30.48 cm) wire leads @ 18 AWG (0.75 mm2). • DF-52068:A•8/19/2014—Page 1 of 2 Wiring Diagrams • Relay-Energized LED (-) N N MT .— 8W C d 8LK • # YEL NC 10.0 Amp Contacts (+) C RED -- NO L +_ 115 VAC @ 0.015 Amp IL- 24 VAC @0.015Amp 24 VDC @ 0.015 Amp PAM-1 Relay-Energized LED OV (-1 — 0 FLU O +24V GRY YEL NC 7.0 Amp Contacts +12VRED QGNO --->PAM-2 • Relay-Energized LED (-) RED , . A BLU C O • YEL NC 10.0 Amp Contacts (+) BLK 0 NO PAM-4 FireLite®Alarms is a registered trademark of Honeywell International Inc. ©2014 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 1 S O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • SYSTEMS E R-r F E U We cannot cover all specific applications or anticipate all requirements. ENRINEERINR 8 MANUFACTURING QUALITYAll specifications are subject to change without notice. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—DF-52068:A•8/19/2014 4.-, ,.' SYSTEM SENSORII I I III I I L l t t i FI ttt4 ttlt F, Indoor Selectable- 1 1 Output Horns, 4 Strobes, and Horn Strobes for Wall Applications E System Sensor L-Series audible visible notification l Y products are rich with features guaranteed to cut s�.h - - :, ti installation times and maximize profits with lower current draw and modern aesthetics. ` e 4' Features __ • • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Plug-in design with minimal intrusion into the back box plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns, strobes,and horn strobes • Field-selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110, 135,and 185 while simplifying installation.All devices feature plug-in designs • Horn rated at 88+ dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming ground faults, • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,the L-Series utilizes a universal mounting plate for all • Electrically Compatible with legacy SpectrAlert and SpectAlert models with an onboard shorting spring,so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING ,_ O ® , • U` LISTED APPRWf� h S5512 FM approved except 7125-1653.0504 S4011 for ALERT models 7135-1853'.0503 3057383,3057072 L-Series Specifications Architect/Engineer Specifications • General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/a-inch back box,4 x 4 x 11-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 11/e-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuif°Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more • synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. PhysicaVElectrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1.2 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7-W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mmW x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. • UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) • 8 C17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3,1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWRInput 15cd 30cd 75cd 95cd 110cd 135cd 185cd • Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 • 9" Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on the 2-wire horn strobes. L-Series Dimensions 1.91 III '�3.46 -� 1.25 3.46 —� 1.25 ------- - r—.1— o ° , 11/•11 000000 11.1.1.11.1.1. ogo°oo000000r 5.27 ill 000000000000 5.27 000000000000a 01000t0,11000 10 0It011t1tt ,I�► ill' 1 1:111 51.1 1i) i 1( Compact Strobe/Horn Strobe Compact Horn 4.70 .___ 1.91 1.25 I ' �.70 �\ ' 1.25 11111 rin�r,uue5.67 67I!: t�t J,, Strobe/Horn Strobe Horn • L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns P2RL 2-Wire,Horn Strobe,Red HRL Horn,Red P2WL 2-Wire,Horn Strobe,White HWL Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL Compact Horn,Red P2GWL 2-Wire,Compact Horn Strobe,White HGWL Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red, Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box, Red Wall Strobes SBBWL Wall Surface Mount Back Box,White -->SRL Strobe,Red SBBGRL Compact Wall Surface Mount Back Box,Red SWL Strobe,White SBBGWL Compact Wall Surface Mount Back Box,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover rc C l All-ALERT models have'ALERT"marking on cover • 6 EM 3825 Ohio Avenue•St.Charles, IL 60174 ®zon System Sensor. Product specifications `` ,yJ Phone:800-SENSOR2•Fax:630-377-6495 subject to change Without rrotice.viat eystemcensorwn r�j /"��+° far°anent product information,including the latest version of tnis data sheet. >G/�/SL//1 wwwsystemsensoccom AVl)586503.03/17 *Th SYSTEM L....$ SENSOR Indoor Selectable- Output Strobes and ,,i k '- *_: Horn Strobes for = - Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut ' 4 Aft installation times and maximize profits with lower „',fir current draw and modern aesthetics. ' ,-*"�= >0 Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry • with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30, 75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn torte and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING L Y i USTED APPROVED S5512 FM approved except 7125-1655'0504 S4011 for ALERT models 7135-16530503 3057363 AVOSSSS-02•1 2/0 1/2 0 1 7•Page 3 L-Series Specifications Architect/Engineer Specifications . General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit"'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch,The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. • Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5'high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. • AVDS888-02•12/01/2017•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) • 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWRInput 15cd 30cd 75cd 95cd 115cd 150cd 177cd • Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 • A405888-02.12/01/2017•Page 2 L-Series Dimensions • 2.47'(62.7 mm) 1.37'(34.8 mm) — 6.92"diem. 2.5' 6.83'dim (175.77 mm)A If— (64 mm)1 (173 min) +��n I I Q 7.7....0____4„..........\\\n I7___8°oO o v_.._Il , 1 ' C ..�: goo 0CD 02, 0 A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box 1,./4es illi-v. -vt----. (e, ,c, tic ///- 4; ;/:711111b,.... ,..,4, --_._1%k___,/ 1 r® �I ( \-- Iwggal ,,.,.,,,,,...::::,„.„,„ , kz _ i i,ca i t -0,,',,-/- ' ''.'"Fi ,', 0 tor tu, Pi 3k_ ' ,,;',..t.r.--- ::',. . 'ii.:, III i!lr/' Li - ,,.., .4%8_ r , ...,7,27..t„,_::::„::: T.4: ,.,i---_,17.79 1111 A0494-01 _--. A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire, Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications".• ��5�''''����////��w 02017 System Sensor �� �+4rcw;�rQ 3825 Ohio Avenue•St.Charles, IL 60174 Product ncabonesubjecttochange,ameutnrnee Aertsystemeens«.com ��`��`777������"'lll GEAI5OR Phone:800-SENSOR2•Fax:630-377-6495 '«current product information,Including the latest version w this data sheet. AVDSS68-02•12/01/2017 *-, � / - / ! EA l i �f�r. -i_i-1,Lt.l.i.l,f�r .. SENSOR lt ,IlIl ililililifililfl� i l tiff 11 1110110111111;. 1111 •F fill 1161I1 Ilif tlf 111 f l i 1111 1f 11 1111 1111 Indoor Selectable- 1 ;1•• to i1 • I I � i, ar >kw 1 i Output Speaker ly 4, • 7; and Dual Voltage Evacuation F Speakers for Wall Applications ' System Sensor L-Series selectable output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. The System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal Features mounting plate that allow the installer to pre-wire mounting plates, • • Plug-in design and protective cover reduce ground faults dress the wires,and confirm wiring continuity before plugging in the speakers. In addition,a protective plastic cover prevents nicked • Universal mounting plate with an onboard shorting spring tests wires by covering exposed speaker components. wiring continuity before installation • No extension ring required These devices also enable faster installations by providing instant • Field selectable candela settings on wall units: feedback to ensure that wiring is properly connected, rotary switches 15,30,75,95, 110, 135, 185 to select voltage and power settings,and 7 field-selectable candela settings for wall speaker strobes. • Automatic selection of 12-or 24-volt operation at 15 and 30 candela The low total harmonic distortion of the speaker offers high fidelity • Rotary switch simplifies field selection of speaker voltage sound output while still offering high volume sound output for use (25 and 70.7 Vrms)and power settings(1/4,1/2, 1 and 2 watts) in high ambient noise applications. • Speakers offer high fidelity and high volume sound output System Sensor L•Series makes installation easy • 520 Hz+/- 10%square wave tone capable with compatible FACP •Attach a universal mounting plate to a 4 x 4 x 21/8 inch back box. • Compatible with System Sensor synchronization protocol Flush-mount applications do not require an extension ring. • Electrical compatibility with existing SpectrAlert and SpectrAlert •Connect the notification appliance circuit or speaker wiring to the Advance products terminals on the mounting plate. •Attach the speaker or speaker strobe to the mounting plate by • Tamper-resistant construction inserting the product tabs into the mounting plate grooves.Hinge • Updated modern aesthetics the device into position to lock the product pins into the mounting plate terminals.The device will temporarily hold in place with a Agency Listings catch until it is secured with a captured mounting screw. SIGNALING 'a U� 4,fg `/I _ 1 • LISTED APPROVED FM app. , . axcepl 7320-165905 5 for ALERT rnudels 3657493 AVD5867-03•6/6/2019•Page 1 L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications • General L-Series speaker and speaker strobes shall mount to a 4 x 4 x 21/e-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate.Also,L-Series speaker strobes,when used with the Sync.CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC,or full-wave rectified,unfiltered power supply.Wall- mount speaker strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135, 185. Speaker The speaker shall be aSp System Sensor L-Series model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms.It should be listed to UL 1480 and shall be approved for fire protective service.The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F.The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems.The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch,and shall have a frequency range of 400 to 4,000 Hz.The speaker shall have power taps that are selected by rotary switch.The strobe shall comply with the NFPA 72 requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize strobes at 1 Hz.The module shall mount to a 411/16 x 411/16 x 2'/8-inch back box.The module shall also control two Style Y (class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F(0°C to 49°C) • Humidity Range 10 to 93%non condensing Dimensions,Wall-Mount Length Width Depth SPL Speaker 6.5 in,165 mm 5 in, 127 mm 0.97 in,23 mm With Surface Mount Back Box 6.6 in,168 mm 5.1 in, 130 mm 3.2 in,82 mm SPSL Speaker/Strobe 6.5 in,165 mm 5.0 in, 127 mm 2.3 in,58 mm (including lens and speaker) With Surface Mount Back Box 6.6 in,168 mm 5.1 in, 130 mm 4.5 in, 116 mm *When using 12AWG, 14 AWG,or adding extra wires in the box,a deeper box or extension ring is recommended. Electrical/Operating Specifications Nominal Voltage(speakers) 25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage(speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage(strobes) Regulated 12 VDC or regulated 24 DC/FWR1.2 Operating Voltage Range(includes fire 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) alarm panels with built in sync) Operating Voltage with MOL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Frequency Range 400 to 4000 Hz3 Power 1/4,'h, 1,2 watts 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 and 30 cd 3.520 Hz+/-10%square wave tone capable with compatible FACP. • AVDS867-03•6/6/2019•Page 2 UL Current Draw Data UL Max Strobe Current Draw(mA RMS) • 8 to 17.5 Volts 16 to 33 Volts Candela DC DC FWR 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 Sound Output Speaker Strobe 1/4 W Vz W 1W 2 W UL Reverberant(dBA©10ft) 77 80 83 86 UL Anechoic(dBA C410 ft) 77 80 83 86 Sound Output Speaker 1/4 W 1/z W 1 W 2W UL Reverberant(dBA 010 ft) 79 82 85 88 UL Anechoic(dBA r10 ft) 79 82 85 88 L-Series Dimensions 0.97" - = 1.63' „�_ 5„ (24.64 mm) (41.66 mm) 2.3' • (127 mm) - 5' (55 mm) (4t66 mm) (127 mm) 1.39" IIOo0a 0 0 0 "\ T— (35.31mm) : ' n° 0° 0 °0°4° 6.5' al Pla °o'1a°0° iI '' d a5• 1-_-_-_,....-_-_- � %I dill l 4' lI 065 mm) °°; ° O I INC lj I 065 mm) om 00 11 000 000 ° o°�°�a°°°°�o0�„� � pill 4VIAMELL min . III iiirai _El • I A0555-01 i ��:..' N 1 A0555 01 Wall-Mount Speaker Wall-Mount Speaker Strobe • AVDS867-03•6/6/2019•Page 3 Surface Mounting :111117--o-c; ''';'' 414- <,, flei."%j:c,'-'176, ( 'e:iu1: " A� gA pA F 0 nisi, � IL ( 1 A0523-01 Wall-Mount Speaker Strobe with SBBSPRU SBBSPWL Surface Mount Back Box • L-Serie •rdering Information Wall Mount White Red Description SPWL _ SPRL Speaker only SPSWL SPSRL Speaker Strobe SPSWL-P SPSRL-P Plain Speaker Strobe SPSWL-ALERT — Speaker Strobe,Amber Lens SPSWL-CLR-ALERT — Speaker Strobe Clear Lens SPSRL-SP Speaker Strobe,Fuego Accessories White Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SBBSPWL SBBSPRL Surface Mount Back Box for Speakers and Speaker Strobes TR-2W TR-2 Wall Mount Trim Ring Notes: All-P models have a plain housing(no"FIRE"marking on the cover) • Sys-TEM 3825 Ohio Avenue•St.Charles, IL 60174 02019System sensor �r•r ��a Phone:800-SENSOR2•Fax: 630-377-6495 Product speciriceems subject to change wnMu:notice.Aso systemsensor can _'`ly J for current product information,Including g latest version of this data sheet Y www.systemsensor.com AVDS367-03.6/W2019 OSID Wire Guard OStD_WG ,s' Features ,444411 • r4ilp"4%.,000P • Designed to not interfere with the III,/ operation of the protected unit. `l leo'� '11 • Fast and easy installation. / `,``'" `� • Simple removal for servicing the units. / `� ', '1 • Constructed from 9 gauge galvanised I steel rod. r�"� r ill nd use in ` �� Plastic coated for du ale ty a` �l,`�I� harsh environments. tt\- 1, Iih))iJJ • Protects against vandalism or accidental ' ' damage , •--",,,..\-.....iiiillsw.9, Application This steel cage is designed to protect OSID Imagers and Emitters from vandalism and accidental damage. The cage is constructed of heavy gauge steel wire with corrosion resistant polyester coating. Installation and servicing are easy. Highly recommended for areas where abuse to beams is severe. 0 ■ 1 4 Specifications 11112_0 � ii (1°4mm) 1��. �• Material: Hard drawn steel wire Thickness: 9 gauge-0.144"(0.366mm)Diameter Finish: Polyester Powder Coating- 6Jin. Non Carcinogenic (167mm) Colour: White HMIS: Code-010E 91 In. (134mm) Ordering Codes _—% OSID-WG Wire Guard for Imager and Emitter www.xtralis.com The Americas+1 781 740 2223 Asia+852 2916 8876 Australia and New Zealand+61 3 9936 7000 UK and Europe+44 1442 242 330 Middle East+962 6 588 5622 0 s i o The contents of this document are provided on an'as is basis.No representation or warranty(either express or implied)is made as to the completeness,accuracy or reliability of the contents of this document The manufacturer reserv"'hoer s°te right to change designs or epfidfcadpiw wipout obligation and without further notice.except as otherwise provided,al wartenties,elmrcvs or implied,inctuding without limitation any implied warranties of merchantability and fitness for a parawlar purpose are expressly exGuded. ■ This document Includes registered and unregistered trademarks.All trademarks displayed are the trademarks of their respective owners. by 114 � �� A''�'„ Your use of this document does not constitute or create a licence or any other right to use the name and/or trademark and/or label. *', -Th, SYSTEM .... SENSOR. Indoor Selectable- Output Speaker - p p F Strobes and Dual = =� Voltage Evacuation ,. ., ..,#°'`° Speakers for Ceiling ' ` ;,;, , . 'j,f;t Applications .;�r1 art System Sensor L-Series selectable-output speaker strobes ar' A and dual-voltage evacuation speakers can reduce ground vk` faults and enable faster installation with lower current draw ,.; and modern aesthetics. System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal Features mounting plate that allow the installer to pre-wire mounting plates, • • Plug-in design and protective cover reduce ground faults dress the wires,and confirm wiring continuity before plugging in the speakers. In addition,a protective plastic cover prevents nicked • Universal mounting plate with an onboard shorting spring tests wires by covering exposed speaker components. wiring continuity before installation • No extension ring required These devices also enable faster installations by providing instant • Field selectable candela settings on ceiling units: feedback to ensure that wiring is properly connected,rotary switches 15,30,75,95, 115, 150,and 177 to select voltage and power settings.and 7 field-selectable candela settings for both wall and ceiling speaker strobes. • Automatic selection of 12-or 24-volt operation at 15 and 30 candela The low total harmonic distortion of the SP speaker offers high fidelity • Rotary switch simplifies field selection of speaker voltage(25 sound output while still offering high volume sound output for use in and 70.7 Vrms)and power settings(1/4, 1/2, 1 and 2 watts) high ambient noise applications. • Speakers offer high fidelity and high volume sound output L•Series makes installation easy • 520 Hz+!-10%square wave tone capable with compatible FACP •Attach a universal mounting plate to a 4 x 4 x 2'/e inch back box. • Compatible with System Sensor synchronization protocol Flush-mount applications do not require an extension ring. • Electrical compatibility with existing SpectrAlert and SpectrAlert •Connect the notification appliance circuit or speaker wiring to the Advance products terminals on the mounting plate. •Attach the speaker or speaker strobe to the mounting plate by • Tamper-resistant construction inserting the product tabs into the mounting plate grooves.Hinge • Updated modern aesthetics the device into position to lock the product pins into the mounting plate terminals.The device will temporarily hold in place with a Agency Listings catch until it is secured with a captured mounting screw. SIGNALING • IVO APPROVED S4048 FM approved except 7320-1653QMM for ALERT models 3057493 AVDS866-03.03/23/2018•Page 1 L-Series Speaker and Speaker Strobe Specifications ArchitecturalEngineering Specifications • General L-Series speaker and speaker strobes shall mount to a 4 x 4 x 21/e-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate.Also,L-Series speaker strobes,when used with the Sync.CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC,or full-wave rectified,unfiltered power supply.Speaker strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150, 177. Speaker The speaker shall be a System Sensor L-Series model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms.It should be listed to UL 1480 and shall be approved for fire protective service.The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F.The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor[-Series model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems.The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch,and shall have a frequency range of 400 to 4,000 Hz.The speaker shall have power taps that are selected by rotary switch.The strobe shall comply with the NFPA 72 requirements for visible signaling appliances,flashing at 1 Hz over the strobes entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz.The module shall mount to a 411/16 x 411/16 x 21/s-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F(0°C to 49°C) • Humidity Range 10 to 93%von-condensing Dimensions,Ceiling-Mount Diameter Depth SPC Speaker 6.8 in, 173 mm 1.0 in,25 mm With Surface Mount Back Box 6.9 in, 176 mm 3.5 in,89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in,73 mm With Surface Mount Back Box 6.9 in, 176 mm 5.37 in, 136 mm *When using 12AWG,14 AWG,or adding extra wires in the box,a deeper box or extension ring is recommended. Electrical/Operating Specifications Nominal Voltage(speakers) 25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage(speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage(strobes) Regulated 12 VDC or regulated 24 VDC/FWR 1.2 Operating Voltage Range(Includes fire 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) alarm panels with built in sync) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Frequency Range 400 to 4,000 Hz3 Power 1/4,1 ,1,2 watts 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 and 30 cd. 3.520 Hz+/-10%square wave tone capable with compatible FACP. • AVQSB136-03.03/23/2018•Page e 2� 9 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) . Candela 8 to 17.5 Volts 16 to 33 Volts DC DC FWR 15 87 41 60 30 153 63 86 75 NA 111 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 Ceiling-Mount Speaker Sound Output Setting UL Reverberant(dBA 010 ft) UL Anechoic(dBA 010 ft) 1/4 W 79 79 1/2 W 82 82 1 W 85 85 2 W 88 88 Ceiling-Mount Speaker Strobe Sound Output Setting UL Reverberant(dBA 010 ft) UL Anechoic(dBA 010 ft) 1/4 W 77 77 1/2 W 80 80 1 W 83 83 2 W 86 86 L-Series Dimensions • rA de. 1.0' 1b2• a (V3 mm) (25 (Itfi6 mm) /j.''O fi rf: ?�\'T r I //liy 2 s4\ \, Ill1 �II 4(1 ia1 iI1III ~ i II r)111 _ Iullllrl,,F. IIIrllj 111' l�III 1 11�I .�r 1i11i hl - 111III Afi 1 % 4 e/ � �L A0643 00 Ceiling Speaker zer . (72 "") µtee rll) (n3 mm0 vt NA3 mN po10en1.41 _ 11.1 1,4" .. 1141 1 ho-r,i't. I' o-l. . ... 1 oki _,„0,427,4ii .. ,s‘......:44..,,,,,, .4........,......wiz„.. _...44..,:w.......,,, .i • , A0544-00 Ceiling Speaker Strobe AVDS866-03•03/23/2016•Page 3 Surface Mounting e. „,. , 4-8, ,. _ ._,,,.... ..... s , /4/.-----,.. , , . �83 �g .a rzt.. \1 -- kl�ht n is ''4 •,,..-11?.II .W KI'r S"., \ '' 1.$&t •0,. czr OI �, a .,: N ias ,t s$� 1 r1t.- 1 40 / A0504-61 Ia x : i/ A0520-01 Ceiling Speaker with Surface Mount Back Box Ceiling Speaker Strobe with Surface Mount Back Box oho 0 L, :;;1 -./ A0542-00 Ceiling Speaker Strobe with Trim Ring and 4"Square Electrical Box L-Series Ordering Information Ceiling Mount White Red Description SPCWL _,.,__�SPCHL Speaker only SPSCWL SPSCRI_ Speaker Strobe SPSCWL-P Plain,Speaker Strobe SPSCWL-SP — Fuego,Speaker Strobe SPSCWL-CLR-ALERT — Alert,Speaker Strobe,Clear Lens Accessories White Red Description SBBCWL SBBCRL Universal Ceiling Surface Mount Back Box TRC-2W TRC-2 Universal Ceiling Trim Ring • '- SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 0201Esystem Sensor Phone:800-SENSOR2•Fax:630-377-6495 Productspecaicatians subject to change without nonce Visitsyslemsensa cave SEA/S•O ' to current product iMormaton,includirg the latest version of Nis data sneet. j�J (� www.systemsensoccom AVOS066-03•0312.31201E 1 f SYSTEM _ - :-_, _ .., • �$ SENSOR' %f t Outdoor, Selectable- E _ - i Output Speaker E'' Strobes and Dual- .` , Voltage Evacuation Speakers for Wall Applications SPECTR_Iert o n v a N c E SpectrAlerP Advance outdoor, selectable-output speaker strobes and dual-voltage evacuation speakers meet SpectrAlert Advance offers the broadest line of outdoor speakers and speaker strobes in the industry.From metal and plastic virtually any outdoor application requirement. outdoor back boxes,to white and red plastic housings,to wall and ceiling mounting options,SpectrAlert Advance can meet virtually any application requirement. Features • Weatherproof per NEMA 4X, IP56 Wall-mount outdoor speakers and speaker strobes can be used • indoors or outdoors in wet or dry applications,and can provide • Rated from -40°F to 151°F reliable operation from-40°F to 151°F.These speakers provide • Plug-in design reduces ground faults a broad frequency response range,low harmonic distortion and • Universal mounting plate with onboard shorting spring that tests maintain a high sound pressure level at all tap settings to provide wiring continuity before devices are installed accurate and intelligible broadcast of evacuation messages. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,wall-mount outdoor speakers 135, 150, 177,and 185 and speaker strobes include a variety of features that increase • Automatic selection of 12-or 24-volt operation at 15 and application flexibility and simplify installation.First,field-selectable 15/75 candela settings,including candela,speaker voltage and power settings,and • Rotary switch for speaker voltage(25 and 70.7 Vrms)and power automatic selection of 12-or 24-volt operation enable installers to settings(1/4, 1/2, 1 and 2 watts) easily adapt devices to meet requirements. • Compatible with System Sensor synchronization protocol and Next,these devices use a universal mounting plate with an onboard legacy SpectrAlert products shorting spring that ensures wiring continuity before devices are • Tamper-resistant construction installed,so installers can verify proper wiring without mounting the • Listed for ceiling or wall mounting devices and exposing them to potential construction damage.Once the plates are mounted,all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater Agency Listings corrosion. Knock-outs located on the back eliminate the need to drill • SIOIAUND holes for screw-in mounting.Plastic and metal weatherproof back 0 () MEA boxes come with%-inch top and bottom conduit entries and%-inch LISTED l' • 1 approved knock-outs at the back.A screw-in NPT plug with an 0-ring gasket 7550 7320-1653201 10-08.5 for a watertight seal is included with each back box. SpectrAlert®Advance Outdoor Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications • General SpectrAlert Advance outdoor speakers and speaker strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance speaker strobes,when used with the Sync•Circuit° Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40°F and 151°F from a regulated DC,or full-wave rectified,unfiltered power supply. Speaker Speaker shall be a System Sensor SpectrAlert Advance Model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms.Speaker shall be listed to Underwriters Laboratories Standard S4048 for outdoor fire protective signaling systems.Speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature from-40°F to 150.8°F.Speaker shall have power taps and wattage settings that are selected by rotary switches.The speaker must be installed with its weatherproof back box in order to remain outdoor approved per UL listing S4048.The speaker shall be suitable for use in air handling spaces and wet environments. Speaker Strobe Combination The speaker strobe shall be a System Sensor Model listed to UL 1638 and UL 1480 and be approved for fire protective signaling systems.Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms and shall have a frequency range of 400 to 4,000 Hz.Speaker shall have power taps that are selected by rotary switch.The strobe shall consist of a xenon flash tube with associated lens/reflector system and operate on either 12 or 24 volts.The strobe shall also feature selectable candela output,providing options for 15 or 15/75 candela when operating on 12 volts and 15, 15/75,30,75, 110, 115, 135, 150, 177 or 185 candela when operating on 24 volts.The strobe shall comply with the Americans with Disabilities Act requirement for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The speaker strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The speaker strobe shall be suitable for use in wet environments. Physical Specifications Operating Temperature -40°F to 151°F(-40°C to 66°C) Dimensions,Wall-Mount SPS Speaker Strobe 6.0"L x 5.0"W x 4.7"D(including lens and speaker) • SP Speaker 6.0"L x 5.0"W x 2.9"D Dimensions,Wall-Mount Weatherproof Back Box 6.5"L x 5.5"H x 2.9"D Electrical/Operating Specifications Nominal Voltage(speakers) 25 V or 70.7 V(nominal) Maximum Supervisory Voltage(speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage(strobes) Regulated 12 VDC/FWR or regulated 24 DC/FWR Operating Voltage Range(includes fire alarm 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) panels with built in sync) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Frequency Range 400 to 4,000 Hz Power 1/4,1/2,1,2 watts • AVDS11301 UL Current Draw Data Candela Derating UL Max.Strobe Current Draw(mA RMS) For K series products used at low • Candela 8DC to 17.5 Volts 16 to 33 Volts DC FWR temperatures,listed candela ratings must be FWRreduced in accordance with this table. Standard 15 123 128 66 71 Strobe Output(cd) Candela Range 15/75 142 148 77 81 Listed Candela Candela rating at 30 NA NA 94 96 —40°F 75 NA NA 158 153 15 95 NA NA 181 176 15/75 Do not use below 32°F 110 NA NA 202 195 30 115 NA NA 210 205 75 44 High 135 NA NA 228 207 95 70 Candela Range 150 NA NA 246 220 110 110 177 NA NA 281 251 115 115 185 NA NA 286 258 135 135 Sound Output 150 150 UL Reverberant(dBA 0 10 ft.) 2W 1W li W Ya W 177 177 Outdoor Speaker 90 87 84 81 185 185 Outdoor Speaker/Strobe 89 86 83 80 Dimensions .97 -1.84 2.83 5.00- 5.00" 1.60"" • �� 1.84 raj mr a III. 5.98"" 1111111 ii 5 , 7 100"1 ",all n .97 1) OH I I G © t=9 Wall-Mount Outdoor Speaker Wall-Mount Outdoor Speaker Strobe • AVDS11S01 • Surface Mounting • d.,, I�, ,,,, ._,.Iii, zarik,; ______ , s, itl�—,7 �j� *Ili• lr 4_Ir I• , __ k' �;' —.a _ 7.1 ir _ _. Wall-Mount Speaker Strobe with Plastic Weatherproof Back Box Wall-Mount Speaker with Plastic Weatherproof Back Box Ilfy t •� .. i _ NO] 1)1 I "Iirt i :•+ • Ilt t,,,1 Ctii _ 'a Wall-Mount Speaker Strobe with Metal Weatherproof Back Box Wall-Mount Speaker with Metal Weatherproof Back Box • Orden • . Information for SpectrAlert®Advance Outdoor Speakers and Speaker Strobes Wall Mount White Red Description SPWK SPRK Outdoor Speaker(includes plastic weatherproof back box) SPWK-R SPRK-R Outdoor Speaker(does not include plastic weatherproof back box) SPSWK SPSRK Outdoor Speaker Strobe,Standard cd(includes plastic weatherproof back box) SPSWK-P SPSRK-P Plain Outdoor Speaker Strobe,Standard cd(includes plastic weatherproof back box) SPSWK-R SPSRK-R Outdoor Speaker Strobe,Standard cd(does not include weatherproof back box) SPSWK-CLR-ALERT — Outdoor Speaker Strobe,Standard cd,Clear Lens,ALERT Printed (includes plastic weatherproof back box) — SPSRHK Outdoor Speaker Strobe,High cd(135,150,177,185)(includes plastic weatherproof back box) Accessories White Red Description MWBBW MWBB Wall,Metal Weatherproof Back Box Notes: All-P models have a plain housing(no"FIRE"marking on cover) "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units,both the device and back box must be replaced. • STEM ©2012 System Sensor. �� SENSOR' 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensurcon Phone:800-SENSOR2•Fax:630-377-6495 m'current producnntormation,Including the latest version of this data sheet AVDS11301•OB/12 *Th, S`YSTEM ,•rr•rr1.1•r1'1`riililll l i�. SENSOR ;'I':1F11i111111,11111�1�.1 11 11 111I 111111111111111111r 1i11 .1.1 11t1111111111111111 1 1 1 i•1•11 11111111111 1111111 1111 a ill1 Indoor Selectable- 11111 = . , 1111 111 Ilii 111 11 1r .,. tr. 1e Output Speaker Strobes and Dual ' i`§ Voltage Evacuation 1 Speakers for Wall p Applications System Sensor L-Series selectable output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. The System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal • Features mounting plate that allow the installer to pre-wire mounting plates, • Plug-in design and protective cover reduce ground faults dress the wires,and confirm wiring continuity before plugging in the speakers. In addition,a protective plastic cover prevents nicked • Universal mounting plate with an onboard shorting spring tests wires by covering exposed speaker components. wiring continuity before installation • No extension ring required These devices also enable faster installations by providing instant • Field selectable candela settings on wall units: feedback to ensure that wiring is properly connected,rotary switches 15,30,75,95, 110, 135, 185 to select voltage and power settings,and 7 field-selectable candela settings for wall speaker strobes. • Automatic selection of 12-or 24-volt operation at 15 and 30 candela The low total harmonic distortion of the speaker offers high fidelity • Rotary switch simplifies field selection of speaker voltage sound output while still offering high volume sound output for use (25 and 70.7 Vrms)and power settings(1A,1/2, 1 and 2 watts) in high ambient noise applications. • Speakers offer high fidelity and high volume sound output System Sensor L-Series makes installation easy • 520 Hz+/- 10%square wave tone capable with compatible FACP •Attach a universal mounting plate to a 4 x 4 x 21/8 inch back box. • Compatible with System Sensor synchronization protocol Flush-mount applications do not require an extension ring. • Electrical compatibility with existing SpectrAlert and SpectrAlert •Connect the notification appliance circuit or speaker wiring to the Advance products terminals on the mounting plate. •Attach the speaker or speaker strobe to the mounting plate by • Tamper-resistant construction inserting the product tabs into the mounting plate grooves.Hinge • Updated modern aesthetics the device into position to lock the product pins into the mounting plate terminals.The device will temporarily hold in place with a Agency Listings catch until it is secured with a captured mounting screw. SIGNALING -<_ o • ► a.' • LISTED APPROVED 64046 FM approved except 7320-16530605 'or ALERT models 3057a93 AVD5667.03•6/6/2019•Page 1 L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications • General L-Series speaker and speaker strobes shall mount to a 4 x 4 x 21/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate.Also,L-Series speaker strobes,when used with the Sync•CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC,or full-wave rectified,unfiltered power supply.Wall- mount speaker strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135, 185. Speaker The speaker shall be aSp System Sensor L-Series model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms.It should be listed to UL 1480 and shall be approved for fire protective service.The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F.The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems.The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch,and shall have a frequency range of 400 to 4,000 Hz.The speaker shall have power taps that are selected by rotary switch.The strobe shall comply with the NFPA 72 requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize strobes at 1 Hz.The module shall mount to a 4t1/16 x 411/16 x 21/a-inch back box.The module shall also control two Style Y (class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F(0°C to 49°C) • Humidity Range Dimensions,Wall-Mount 10 to 93%non-condensing Length Width Depth SPL Speaker 6.5 in,165 mm 5 in, 127 mm 0.97 in,23 mm With Surface Mount Back Box 6.6 in,168 mm 5.1 in, 130 mm 3.2 in,82 mm SPSL Speaker/Strobe 6.5 in, 165 mm 5.0 in, 127 mm 2.3 in,58 mm (including lens and speaker) With Surface Mount Back Box 6.6 in,168 mm 5.1 in, 130 mm 4.5 in, 116 mm 'When using 12AWG, 14 AWG,or adding extra wires in the box,a deeper box or extension ring is recommended. Electrical/Operating Specifications Nominal Voltage(speakers) 25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage(speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage(strobes) Regulated 12 VDC or regulated 24 DC/FWR1'2 Operating Voltage Range(includes fire 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) alarm panels with built in sync) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Frequency Range 400 to 4000 Hz3 Power %,1/2, 1,2 watts 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 and 30 cd 3.520 Hz+/-10%square wave tone capable with compatible FACP. • AVOS88I-03•8/8I2019•Page 2 UL Current Draw Data UL Max Strobe Current Draw(mA RMS) • Candela 8 to 77.5 Volts 16 to 33 Volts DC DC FWR 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 Sound Output Speaker Strobe '/a W 'h W 1W 2W UL Reverberant(dBA 010 ft) 77 80 83 86 UL Anechoic(dBA®10 ft) 77 80 83 86 Sound Output Speaker 1/4W 1/2W 1W 2W UL Reverberant(dBA 010 ft) 79 82 85 88 UL Anechoic(dBA®10 ft) 79 82 85 88 L-Series Dimensions 0.67' - - = 1.63" • 5MN - (2464 mm) (91.66 mm) 23" 1.63" (127 mm) (127 mm) (55 mm) 139" (4t65 mm) IIII 00 onoo°'>no�a°e°a°nI }}$ 'II �lil 6.5' ii Pb gli I ) 11°a°. (im o.0°o ` `,, ,, �hr t A055501 _ ApssE-ol Wall-Mount Speaker Wall-Mount Speaker Strobe • AVOSe67-03•6/6/201 B•Page 3 Surface Mounting • 4 �� Ilf :' 10 ® AAA®.B_ AAA, ‘itj iit® e®ABAA°pe,OAA®ApAA ti;—tIn°AA°IBI 64 8 thip A I B®BA 'A°B°BA°1BAAAABAaBp: ti II '- 0 �1,„1 ABB ,00pea°aeage°aac� 9ll A a0 Aaaa®. ti �.�i.;.; �' 11111111 Apes \�1 oiiiii, 1.1•i1i I I I i1y1 1 111 1 r A0523-01 Wall-Mount Speaker Strobe with SBBSPRLJ SBBSPWL Surface Mount Back Box • L-Series Ordering Information Wall Mount White Red Description SPWL �SPRL Speaker only SPSWL SPSRL Speaker Strobe SPSWL-P SPSRL-P Plain Speaker Strobe SPSWL-ALERT — Speaker Strobe,Amber Lens SPSWL-CLR-ALERT — Speaker Strobe Clear Lens SPSRL-SP Speaker Strobe,Fuego Accessories White Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SBBSPWL SBBSPRL Surface Mount Back Box for Speakers and Speaker Strobes TR-2W TR-2 Wall Mount Trim Ring Notes; All-P models have a plain housing(no"FIRE"marking on the cover) • *T SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 02019 System Sensor ` S �SQ�� Phone:800-SENSOR2•Fax:630-377-6495 R°dacsvecrlicabans subject mrnangewithoutnonoo vnaAalemaensorcorn �3 G Y I% for current product inlurmation,including the latest version d this data sheet. vnvwsystemsensor.com AVDS887-03.8/8(2019 any s �a rip, i • . a Duct Smoke . Detector Accessories §. Expand the versatility of the InnovairFlex'line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories Duct smoke detector accessories add functionality to the duct APA151 Piezo Annunciator smoke detection system by allowing quick,convenient inspections at eye level and effective audible and visible notification options.All MHR Mini-Horn, Red System Sensor duct smoke detectors and accessories are UL listed. MHW Mini-Horn,White The APA151 piezo annunciator,which replaces the APA451 with a RA100Z/RA100ZA Remote Annunciator new,improved look, provides an audible alarm signal,a red LED to RTS151 Remote Test Station indicate alarm status,and a green LED to indicate power status. It is RTS151KEY Remote Test Station with Key intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel,to comply with RTS2 Multi-Signaling Accessory NFPA 90A. AOS Add-On Strobe The MHR and MHW SpectrAlert®Advance mini-horns feature RTS2-AOS Multi-Signaling Accessory temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. The RA100Z and RA1 OOZA remote annunciators are designed for both conventional and intelligent applications.Their red LED rovides visual indication of an alarm condition. The RTS151 a RTS151KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location.For 4-wire detectors,the RTS151KEY test station features a multi-colored LED that alternates between steady green and red.For 2-wire detectors,the LED illuminates red for alarm. The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFlex 4-wire conventional duct smoke detectors.These accessories include a key switch that can be used to select one of two connected sensors to be tested,reset,or both Agency Listings by a push button switch.They also enable sensitivity measurements III using the SENS-RDR sensitivity reader(sold separately).The AOS ® C E (Add-On Strobe)is an optional accessory included with the RTS2- AOS model. LISTED APPROVED 7300:1653.0212 7300-1653.0211 32522 3034401 7135-1653.0196 9080301 Specifications, Duct Smoke Detector Accessories APA151 Piezo Annunciator RTS151 Remote Test Station • Voltage Regulated 24 VDC Power Requirements Alarm LED:2.8 to 32 VDC, 12 mA max. Operating Voltage 16 to 33 VDC Total Current: 105 mA max. Maximum Alarm Current 30 mA Test Switch 10 VA @ 32 VDC Temperature Range 0°C to 49°C(32°F to 120°F) Reset Switch 10 VA©32 VDC Relative Humidity 10 to 93%non-condensing Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range -10°C to 60°C(14°F to 140°F) Dimensions 4.6"H x 2.9"W x.45"D Relative Humidity 95%non-condensing MHR/MHW SpectrAlert®Advance Mini-Horns Wire Gauge 14 to 18 AWG Voltage Regulated 12 DC or FWR(Full Wave Dimensions 4.8"H x 2.90"W x 1.4"D Rectified)or Regulated 24 VDC or FWR RTS151 KEY Remote Test Station with Key Sounder Current Draw 22 mA RMS max.at 8 to 17.5 Volts DC Power Requirements Power LED(Green): 14 to 35 VDC, 29 mA RMS max.at 16 to 33 Volts DC 12 mA max. Temperature Range 0°C to 49°C(32°F to 120°F) Alarm LED(Red):2.8 to 32 VDC, 12 mA max. Humidity Range 10 to 93%non-condensing Total Current: 105 mA max. Nominal Sounder 3 kHz Frequency Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range -10°C to 60°C(14°F to 140°F) Dimensions 4.6"H x 2.9"W x 0.45"D Relative Humidity 95%non-condensing RA100Z/RA100ZA Remote Annunciator Wire Gauge 14 to 18 AWG Voltage Range Conventional System:3.1 to 32 VDC Dimensions 4.6"H x 2.75"W x 1.8"D Intelligent System: 18 to 32 VDC RTS2 and RTS2-AOS Multi-signaling Accessory Maximum Alarm Current 10 mA Voltage 20 to 29 VDC Dimensions 4.6"H x 2.8"W x 1.3"D Power Requirements Standby:3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe:30 mA max. Alarm with strobe:55 mA max. Sounder 85 dBA at ten feet Ill Temperature Range -10°C to 60°C(14°F to 140°F) Relative Humidity 95%non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8"W x 5.3"H x 1.6"D For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. " RTS151 UL S4011 RTS151 KEY UL S2522 APA151 UL S4011 RTS2-AOS UL S2522 RA100Z UL S2522 MHW UL S4011 MHR UL S401' ADS • *Th SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 *2013 System sensor Phone: 800-SENSOR2•Fax:630-377-6495 cmw,ct specnications subject change wiNout none visit sysremsensm.00n) SENSOR' forr4rta9 product lnbrmauon,inS2O2C2the*rest versron of tnis tlata sneer. C wwwsystemsensoccom HV2520202.8/13 ®Simplex System Accessories • UL Listed* 4081 Series End-of-Line Resistor Harnesses Features For use as Class B end-of-line resistor: • Connect these resistor harnesses where end-of-line resistors are required at remote locations to monitor wiring continuity • Refer to specific circuit specifications for end-of-line resistor requirements UL Listed to Standard 864 Product Selection -9-1/2" (241 mm) Model Reference Description** Number 4081-9001 733-892 2.2 k52, 1/2 W 4081-9002 733-893 3.3 kt2, 1 W 0-~----).4081-9003 733-896 4.7 kc2, 1/2 W 4081-9004 733-886 6.8 kt2, 1/2 W 4081-9005 733-984 1.8 k12, 1/2 W 4081-9006 733-890 560 52, 1 W 4081-9007 733-891 1.2 k52, 1 W 4081-9008 733-894 10 kc, 1/2 W 4081-9009 733-912 20 0, 1 W - 4081-9010 733-973 1 kt2, 1 W 4081-9011 733-974 100 0, 1/2 W 4081-9012 733-985 22 k52, 1/2 W Typical 4081 Series Resistor Harness Assembly 4081-9013 734-086 4.99 kt2, 1/2 W, ± 1% (full size except for lead length) 4081-9014 734-092 2.4 kt2, 1/2 W 4081-9015 734-093 1.5 kfl, 1/2 W 4081-9016 734-149 150 k52, 1/2 W Specifications 4081-9017 734-171 3.9 kS2, 1 W 4081-9018 734-168 10 kS2, 1 W Overall Length Approximately 9-1/2"(241 mm) a Wire Length 7"(178 mm)± 1"(25 mm) ** ±5/e tolerance except as noted. Wire Size 18 AWG (0.82 mm2) Insulation 600 V, black Leads Stripped 0.5"(13 mm); tinned • Resistor Resistor leads are crimped to wires Attachment and covered with heat shrink tubing "This product was not approved by ULC,FM,MEA(NYC),or CSFM as of document revision date.Additional listings may be applicable,contact your local Simplex®product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety Products Westminster. S4081-0003 7/2004 HN Series Effective November 2016 HS Series Technical Data TD450049EN Supersedes October 2014 ST Series • Exceder Strobe, Horn Strobe, and Horn Notification Appliances Description Syr , > The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners ��{ with reduced total cost of ownership. Installers will benefit from-,.:: At ifip. its comprehensive feature list, including the most candela options 1 x in one appliance, low current draw, no tools needed for setting t changes,voltage test points, 12/24 VDC operation, universal 1 R E ", (,' mounting base and multiple mounting options for both new and retrofit construction. z >; , The Wheelock Exceder Series incorporates high reliability and high — ' FIRE ` efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe r a; models feature an industry first of 8 candela settings on a single , appliance. Models with an audible feature 3 sound settings (90, 95, 1 99 dB).All switches to change settings, can be set without the use {< ` ® of a tool and are located behind the appliance to prevent tampering. �+ _F -�- Wall models feature voltage test points to take readings with a j voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification i // �, e. appliances feature a Universal Mounting Base (UMB)designed II to simplify the installation and testing of horns, strobes, and combination horn strobes.The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts.The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed.The UMB allows for consistent installation and easy replacement of appliances if required.Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Er ,iiir-,,,N . Powering Business Worldwide Technical Data TD450049EN HN Series Effective November 2016 HS Series ST Series Features • Environmentally friendly •Sleek modern aesthetics Low current draw • Finger slide switches • Up to 9 models now in 1 appliance drawl) • Voltage test points • 12/24VDC on a single appliance • Multiple voltages • Easy to remember model numbers • 3 Audible settings Patented • 90,95,99 dB Note: Please read these specifications and associated installation instruc- tions,before using,specifying,or installing this product.Visit Eaton.com/ • Industry leading-8 candela settings on 1 device massnotification for current installation instructions. • Wall: 15/1575/30/75/95/110/135/185 General Notes • Ceiling: 15/30/60/75/95/115/150/177 • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range" • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F(0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). • Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements • Synchronize using the Wheelock®Sync Modules or panels with built-in Wheelock®Patented Sync Protocol • Universal mouting base • Compatible with UL"Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage • Ceiling and wall • Strobes produce 1 flash per second over the "Regulated •• Mounts to 5 backbox types: 1 gang, 2 gang, 4" square, Voltage" range 3.5"octal. &4" octal. (100mm for international customers) Universal mounting base Contact cover Compliance • UL 1971, UL 464, ULC, CSFM, FM • • ADA/NFPA/ANSI/OSHA '.��4 ' ' � "e ,. • RoHS WOO IMF jA Common base for wall and ceiling with 5 mounting options • Voltage test points for quick troubleshooting and easy spot checking(wall models only) V • 2 EATON www.eaton.com HN Series Technical Data TD450049EN HS Series Effective November 2016 ST Series Table 1. Strobe Ratings per UL Standard 1971 • UL Max Current@ 24 VDC/24 FWR 12 VOC Regulated Voltage Model Range VDC 15 1505 30 60 75 95 110 116 135 150 177 186 15 15/75 ST 8 0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 0.253 0.110 0.140 STC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 0.110 Table 2. Horn Strobe Ratings per UL 1971 &Anechoic at 24VDC UL Max Current@ at Anechoic 99 elBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current()at Anechoic 95 elBA 24 VDC 12 VDC Regulated Voltage Model Range VOC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 - 0.230 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 0.230 0.272 - 0.122 - UL Max Current()at Anechoic 90 dBA 24 VDC 12 VDC Regulated Voltage Model Range VOC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - • 0UL max current rating is the maximum RMS current within the listed voltage range(16.33 VDC for 24 VDC units).For strobes the UL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units).For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units).For unfiltered ratings,see installation instructions. Table 3. Horn Ratings per UL Anechoic Model Legend Regulated Voltage Model Range VDC 99 dB 95 dB 90 dB HN = Horn R = Red HN 16-33.0 0.064 0.044 0.022 ST = Strobe A = Agent Lettering(strobes only) HNC 16-33.0 0.084 0.044 0.022 HS = Horn Strobe AL = Alert Lettering(strobes only) HN 8.0-17.5 0.047 0.026 0.017 C = Ceiling Mount N = No Lettering(strobes only) HNC 8.0-17.5 0.047 0.026 0.017 W = White Example 1:STRC=Strobe,Red,Ceiling Mount Table 4. Specification&Ordering Information Example 2:HSR=Horn Strobe,Red,Wall Mount S new/DSM cr Example 3:HSW=Horn Stroke,White,Wall Mount Wheelock power 12/24 Mounting Example 4:STW-AL=Strobe,White,Wall Mount,Alert Lettering Model Strobe Candela Supplies VDC Options Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X UMB© ..- HSW 15/1575/30/75/95/110/135/185 X X UMB® HSRC 15/30/60/75/95/115/150/177 X X UMB "411..^,, , i' � � y / r HSWC 15/30/60/75/95/115/150/177 X X UMB® +" , Strobes {L''.�t. _7 ' ---- . as 15/1575/30/75/95/110/135/185 X X UMB® "�+ 4 STW 15/1575/30/75/95/110/135/185 X X UM13© - 15/30/60/75/95/115/150/177 X X UMB® !� STWC 15/30/60/75/95/115/150/177 X X UMB0 S # Hem HNR - ` X X UMB@ a " , • HNW X X UMB© ./ .1 1:1 HNRC _ X X UMB© Example. HSR Example:HSWC HNWC X X UMB® 012 VDC models feature 15&15/75 settings 0 UMB=Universal Mounting Base EATON www.eeton.com 3 Technical Data TD450049EN HN Series Effective November 2016 HS Series ST Series Architects and Engineers Specifications Ilke notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series N Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service.The Series HS and HN Audibles shall be UL Listed under Standard 464(Fire Protective Signaling).All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one(1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design.Where multi- candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75,30, 75, 95, 110, 135, 185 candela for wall mount and 15,30, 60, 75,95, 115, 150, 177 candela for ceiling mount.The selector switch for selecting the candela shall be tamper resistant.The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.,ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang,4-inch square, 3.5-inch octal,4-inch octal or 100mm European type back boxes.Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP).The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models.All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58"W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules,Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS 0.iling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal(CSFM), ULC, FM, RoHS Note:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Eaton standard terms and conditions. PZEW al Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Eaton Life safety&mass notification solutions • 273 Branchport Ave. Long Branch,NJ 07740 Eaton.com/massnotification 0 2016 Eaton A _ All Rights Reserved Eaton is a registered trademark. Printed in USA Publication No.TD450049EN All other trademarks ere property Powering Business Worldwide November 2016 of their respective owners. Effective April 2018 Technical Data TD45OO24EN Supersedes July2016 i Wheelock E70 & E90 Speakers & Speaker Strobes Description ) The Wheelock E70 Wall and E90 Ceiling Speakers and Speaker Strobes are designed for high efficiency sound output for indoor applications.The E product line features intelligible communications 1. , I with crisp,clear voice messages and tone signaling, ideal for mass notification,and voice evacuation. Providing a sleek aesthetic appearance,the Wheelock Series E FIRE i High Speaker Strobes feature dual voltage (25/70 VRMS)capability and field selectable taps from 1/8 to 2 watts. The low profile design incorporates a speaker mounting plate for faster and easier installation. Each model has a built-in level adjustment feature and an aesthetic two(2) screw grille cover. For visible signaling to meet the hearing impaired,the E Speaker Strobe models incorporate the Low Current draw RSS Strobes. Strobe options for wall mount models include 1575 orWheelock "`.•'.'•• ' patented MCW multi-candela strobe with field selectable candela :f;.:! settings of 15/30/75/110cd or the high intensity MCWH strobe with ,,,, field selectable 135/185cd. • Ceiling mount models are available in Wheelock patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The strobe portion of all E Speaker Strobes may be synchronized when used in conjunction with the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol.Wheelock ( synchronized strobes offer an easy way to comply with ADA `: °° recommendations concerning photosensitive epilepsy FIRE The E Speaker Strobes are UL Listed for indoor use under Standard II 1971 (Signaling Devices for the Hearing-Impaired)and Standard 1480 / (Speaker Appliances).All inputs employ IN/OUT wiring terminals for fast installation using#12 to#18 AWG wiring. - Color options for the E Speakers and Speaker Strobes are red and white. E A T.N • Powering Business Worldwide Technical Data TD450024EN Wheelock E70 & E90 Effective April 2018 Speakers &Speaker Strobes Features Drawings •Intelligible Communications 5.13 - • Efficient design for high intelligibility at minimum wattage °.N '" across a frequency range of 400 to 4000 HZ , r • Field Selectable Settings 0000000000 000000000000 —�-i1 • Wall mount models are available with Field Selectable Candela °ogg00000g00000, ��■% 1. Settings of 15/30/75/110cd or 135/185cd (Multi Candela models) 0000000000000000 000000000000000000000000000000 00 0000000000000000 °°°°°°°°°°°°°°°° „° 'MII • Ceiling mount models are available with field selectable candela °°°°°°°°°°°°°°°° settings of 15/30/75/95cd or 115/177cd(Multi-candela models) °°°°°°°°°°°°°°°° °°°°°°°°°°°°°°°° ................ � °000000000000o • Field Selectable Taps °0°0000000000 00° oo • 1/8 watt up to 2 watts © , • 25 or 70 VRMS operation 07.27 • Easy-to-Install °" • Low profile design incorporates speaker mounting plate for faster and easier installation • Built-in level adjustment feature and an aesthetic two (2) o o ve8%o". ;� _„ screw grille cover. ?o o o°o°oo t • Quick installation with IN/OUT screw terminals using#12 to si ea e°xees°es° j II #18 AWG wires a°°°°�° I eea 4e e° II to • 4" square backbox prevents wire damage °°° • E70 No extension ring required • E90 Optional extender(E90 Ext) is available for mounting to 4" square backboxes • Strobe Synchronization Components Figure 1.E70(top)and E90(bottom)Speakers-Front&Side Views • Meet synchronizing standards with Wheelock's DSM Sync Modules, Power Supplies or SAFEPATH products e•Compliance 5.13 " —1 • UL 1971, UL 1480 OO • California State Fire Marshal (CSFM) °°°°°°°°°° 0000000°°°4C0 - • ADA/NFPA/ANSI/OSHA °°°°°°°onon—°°°°°°°°° =�- �•. • FCC Part 15, ICES -,^ 1 5» ��■ �I �I�ilI Note: Please read these specifications and associated installation instruc- tions, before using,specifying,or installing this product.Visit Eaton.com/ °°°°°°°°°° -J massnotification for current installation instructions. © 2.6B 256 logithe 11.0 i li; �! II 1 °000 oa 0® Figure 2.E70(top)and E90(bottom)Speaker Strobes-Front&Side Views General Notes • • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range" Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. 2 EATON www.eaton.com Wheelock E70 & E90 Technical Data TD450024EN Speakers & Speaker Strobes Effective April 2018 Table 1. Maximum RMS Current • UL Max Current 01 24MCW/24MCC 24MCWH/24MCCH Regulated Voltage Model Range VDC 16 30 75 95 110 116 136 177 186 E70 16.0-33.0 0.060 0.092 0.165 0.220 0.300 0.420 E90 16.0-33.0 0.065 0.105 0.189 0.249 0.300 0.420 Table 2. UL Listed Models and Ratings UL Reverberant dRA at 10 Feet ' 1/8 watts Model O 1/4 watts 1/2 watts 1 watts 2 watts E70 Speaker 72 75 78 81 83 E90 Speaker 72 75 78 81 82 E70 Speaker Strobe 71 75 78 81 83 E90 Speaker Strobe 74 77 80 82 85 Table 3. Specification&Ordering Information Mounting Sync w/DSM or Model Order N Strobe Candela Red White Lettering Wall Ceiling Options Wheelock Power Supplies Speakers E70-R 9865 X No Lettering X P,O. E70-W 9866 X Na Lettering X P,Q E90-R 9875 X Na Lettering X P,Q E90•W 9876 X No Lettering X P,a Speaker Strobes E70-24M 0183 15/30/75/110 X FIRE X P,O. X E70-24M 1T 0184 15/30/75/110 X FIRE X P,a X E70-24MCW-NW 9748 15/30/75/110 X No Lettering X P,a X E70-24MCW-ALR 4123 15/30/75/110 X ALERT X P,O. X I- •(1 t £ 4124 15/30/75/110 X ALERT X P,a X 0185 135/185 X FIRE X P,O. X 71--• t It'- r 0186 135/185 X FIRE X P,Q X E70-24MCWH-ALW 4456 135/185 X ALERT X P,a X E70-24MCC-ALR 4308 15/30/75/95 X ALERT X P,Q X E70-24MCC-ALW 5838 15/30/75/95 X ALERT X P,a x 7 I- •u -1 1000 15/30/75/95 X No Lettering X P,a X -- ) 0191 15/30/75/95 X FIRE X P,Q X ''i- 4 t - r 0192 15/30/75/95 X FIRE X P,Q X E90-24MCC-NW 3181 15/30/75/95 X No Lettering X P,a X E90-24MCC-ALW 4189 15/30/75/95 X ALERT X P,a x E90-24MCC-ALR 4309 15/30/75/95 X ALERT X P,Q X E90-24MCCH-FR 0194 115/177 X FIRE X P,a X E90-24MCCH-FW 0193 115/177 X FIRE X P,a X E90-24MCCH-ALR 0980 115/177 X ALERT X P,O. X E90-24MCCH-ALW 2975 115/177 X ALERT X P,a X E90-24MCCH-NW 2974 115/177 X No Lettering X P,Q X 0 RMS current ratings are per UL maximum RMS method.UL max current rating is the maximum RMS current within the listed voltage range 116-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage(16v for 24v units). For audibles the max current is usually at the maximum listed voltage(33v for 24v units).For unfiltered FWR ratings,see installation instructions. b dBA ratings are based on testing under UL Standard 1490. c 1/8 watt tap is for private mode only. • Note:Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Eaton standard terms and conditions. EATON www.eatan.com 3 Technical Data TD450024EN Wheelock E70 & E90 Speakers & Speaker Strobes Effective April 2018 Table 4. Specifications Wsical Material Red or white textured UV stabilized,colored impregnated engineered plastic.Exceeds 94V-0 UL flammability rating, Weight E70 Speaker:1.7 lbs(0.77 kg);E70 Speaker Strobe 1.8 lbs(0.82kg);E90 Speaker:1.5lbs(0.68 kg);E90 Speaker Strobe 1.6 lbs(0.73 kg) Lens GE Lexan 943A Dimensions E70 Seeaker: 5.13"W x 5.13"H x 0.43"D;E70 Speaker Strobe: 5.13"W x 5.13"H x 2.56"D;E90 Speaker:7.27"Diameter x 0.43 D;E90 Speaker Strobe:7.327 Diameter x 2.68"D Operating Temperature Indoor:33.8°Fto 120.2°F(0°C to 49°C)and maximum humidity of 93% Mounting&Wire Connections Mounting(indoor only) 4"square backbox with extension ring prevents wire damage;SBB for surface mount of E70 Wire Connections #12 through#18 AWG Power&General Operating voltage 25/70 VRMS Strobe Output Rating UL 1971 Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules,Power Supplies or SAFEPATH products,using Wheelock patented sync protocol Frequency Range 400 Hz to 4000 Hz Architects and Engineers Specifications The speaker appliances shall be Wheelock Series E70 or E90 When synchronization is required,the strobe portion of the appliance Speakers and Speaker Strobe appliances or approved equals.The shall be compatible with Wheelock DSM sync modules,Wheelock speakers shall be UL Listed under UL 1480 for Fire Protective Power Supplies or other manufacturers panels incorporating the Service and speakers equipped with strobes shall be listed under UL Wheelock Patented Sync Protocol.The strobes shall not drift out of 1971 for Emergency Devices for the Hearing-Impaired. In addition, synchronization at any time during operation. If the sync module 40 e strobes shall be certified to meet the requirements of FCC Part or Power Supply fails to operate, (i.e.,contacts remain closed),the ,Class A. strobe shall revert to a non-synchronized flash rate. All speakers shall be designed for a field selectable input of either 25 The speaker and speaker strobe appliances shall be designed for or 70 VRMS,with selectable power taps from 1/8 watt to 2 watts. indoor surface or flush mounting.The speaker and speaker strobe All models shall have listed sound output of up to 87 dB at 10 feet shall incorporate a speaker mounting plate with a grille cover which is and a listed frequency response of 400 to 4000 Hz.The speaker shall secured with two screws for a level, aesthetic finish and shall mount also incorporate a sealed back construction.All inputs shall employ to standard electrical hardware requiring no additional trimplate or terminals that accept#12 to#18 AWG wire sizes. The strobe portion adapter. of the appliance shall produce a flash rate of one(1)flash per second over the Regulated Voltage Range.The strobe shall be of low current The finish of the Series E speakers and strobe speakers shall be red design.Where Multi-Candela Speaker Strobes are specified,the or white. strobe intensity shall have field selectable settings and shall be rated per UL 1971 at 15/30/75/110cd or 135/185cd for wall mount and All speaker and speaker strobe appliances shall be backward 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch compatible. for selecting the candela shall be tamper resistant. UL 1971, UL 1480, CSFM, FCC. le Effaili Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Eaton Life safety&mass notification solutions • Br Lon anch Ave. Long Branch,,rt Na. 7740 www.eaton.com/massnotification ®2018 Eaton EAll Rights Reserved Eaton is a registered trademark. A Punted in USA Publication No.TD450024EN All other trademarks are property Powering Business Worldwide April 2018 of their respective owners. Effective September 2020 Technical Data TD45O112EN Supersedes August 2020 Wheelock AH,AS,MT,RSS,ET70 Weatherproof appliances, Version 2 Description Designed for life safety, performance and reliability, To enable weatherproof mounting, Eaton provides the Wheelock weatherpoof notification appliances the industry's widest choice of mounting options nclude: for surface or unique semi-flush installation. Models are available for surface mounting to Weatherproof Wheelock weatherproof backboxes on walls Appliances Series or ceilings.The optional WP-KIT allows the weatherproof backboxes (IOB,WPBB or WPSBB) Strobes RSSWP to be mounted to a recessed electrical box for Horn strobes ASWP concealed conduit installation. For semi-flush Horn AH-24WP AH-12WP installation,the WPA* and WFPA* kits allow a customer to mount the weatherproof appliances • Multitone horn strobes MTWP to a recessed electrical box without the need Multitone horns MT for an external weatherproof backbox. See Speaker strobes ET70WP Table 10 on page three of this document for a Speakers ET-1010 summarization of these mounting options and the required accessories. All strobe models are UL dual listed—meeting All models may be synchronized using the both UL1638 and UL1971 requirements.As dual Wheelock DSM sync modules,Wheelock listed appliances,these weatherproof strobes, power supplies or other manufacturers panels horn strobes and speaker strobes are listed for incorporating the Wheelock patented sync proto- outdoor applications under UL 1638 as well as col. The horn output of horn strobes can under UL 1971,the Standard for Safety Signaling be independently controlled on 2-wire circuits Devices for Hearing Impaired. With an extended using the Wheelock patented sync protocol. temperature range of-40°F to 150°F(-40°C to MTVVP horn strobe models are 4-wire appliances; 66°C),Wheelock weatherproof appliances meet the strobes can be synchronized while the or exceed UL outdoor test requirements for rain, audible can be connected to a coded fire alarm humidity and corrosion resistance while providing system. MT horns may be synchronized, using multiple strobe intensity options, including the the temporal Code 3 horn setting. highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). F ,T„N • Powering Business Worldwide Technical Data TD450112EN Wheelock AH,AS, MT, RSS, ET70 September 2020 Features & benefits • Weatherproof with extended temperature range of—40°F to ' 150°F (-40°C to 66°C) 11 4.80 it 2.55 • Dual listed strobe models(UL 1638 and UL 1971) �� 1�_ , • Industry's highest strobe candela options A . �'"� A • Strobes and Code 3 horn synchronize using the Wheelock Sync 4.80 Modules or panels with built-in Wheelock Patented Sync Protocol • Models with field selectable tone, dBA and candela settings • Wall or ceiling mounting options • MTWP and ET7OWP kits that include the device and 10B backbox are available;See ordering information for specific models • Surface or semi-flush mounting (indoor and outdoor) • IN/OUT wiring termination accepting two#12-18 AWG wires Figure 2.ASWP front and side views at each terminal Note:Please read these specifications and associated installation instructions, before using, specifying,or installing this product.Visit i Eaton.com/massnotification for current installation instructions. h4 5.126-01 • Approvals & compliances O17olljlllllocro• Approvals include: UL Standards 1971, 1638, 464 and 1480; ULC, °I 46.i0.... — \ 1 California State Fire Marshal (CSFM);and Factory Mutual (FM) I i (see agency approvals by model number on pages 4 and 5 of this document) 5.126 • The series RSSWF ASWP,AH-24WF MTWP-2475W, and A00 0110 �`� MT-12/24 have UL/ULC approval down to—40°F.The ET-1010 0.65 and ET7OWP have UL approval down to—40°F. • Compliance with the following requirements: NFPA; UFC; FCC, • ANSI 117.1; OSHA Part 29, 1910.165;AD Figure 3.MTWP front and side views General notes • Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. i. 5.120 --- 5.368 -*- • All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. (,' ����ii l • Models are available in red or white. Contact Customer Service it ��p'2"P �"✓ ■,' for order code and delivery. og°to8 8° °o°°oo°°o°°o0 5.120 •_ oo°pgo o°000°• E U o°°oiog°^°oo G Drawings , o �pe° o 14— 4.80 ---. 0.602 1411- 0 FIRE ® Figure 4.ET7OWP front and side views 4.80 • C, � J AM 14 5.13 ►I 2.17 0 FIIRE 0 L...........---1 ' ' ®c10 oac� 1 -i� p :� Figure 1.RSSWP front and side views 5.13r: II, . •I • 0oO op® Figure 5.MT front and side views 2 EATON www.eaton.com Wheelock AH,AS, MT, RSS, ET70 Technical Data TD450112EN August 2020 • 4.09 ► ,4.29 Is. o + �mlla iIiiiiiii �_i 14 1.92 111 Figure 6. ET-1010 front and side views Table 1. Maximum RMS current for AH models Table 2. dBA ratings for ET-1010 and ET70WP models UL Max Current for AH UL Reverberant dBA @ 10 ft. 24 VDC Watts High(99)dBA 0.080 Model 1/8 1/4 1/2 1 2 4 8 Med(95)dBA 0.043 ET-1010 77 80 83 86 87 92 94 Low(90)dBA 0.021 E170WP 77 80 83 86 88 91 93 Table 3. Maximum RMS current and dBA,MT weatherproof models MTWP/MT MT UL Reverberant dBA at 10 Feet 24VDC 12 VDC • dBA HI STD HI STD 24HI VDC 12 VDC HI STD HI STD Horn 0.108 0.044 0.177 0.034 92 87 92 87 Bell 0.053 0.024 0.095 0.020 86 March Time 0.104 0.087 0.142 0.034 80 86 80 Code 3 Horn 0.122 0.035 0.200 0.034 89 84 89 84 Code 3 Tone 0.135 0.035 0.152 0.021 88 83 88 83 Slow Whoop 0.098 0.037 0.142 0.035 65 80 85 80 Siren 0.104 0.036 0.152 0.030 90 85 90 85 Hi/Lo 0.057 0.025 0.114 0.026 89 84 89 84 86 81 86 81 Table 4. Strobe and ASWP ratings Candela ratings Maximum RMS Current for ASWP Max RMS Current Strobe Candela UL 1971 UL 1638 @ 77°F UL 1638 @-40°F (strobe only) High Med Low 2475W 30 0 180 115 0.138 0.168 0.155 0.150 2475C 15 180 115 0.138 0.168 0.155 0.150 MCWH 135 135 56 0.300 0.355 0.340 0.335 185 185 77 0.420 0.480 0.465 0.460 MCCH 115 115 47 0.300 0.355 0.340 0.335 177 177 73 0.420 0.480 0.465 0.460 24185 185 185 77 0.420 24177 177 177 73 0.420 0 Wall mount rating only • EATON www.eaton.com 3 Technical Data TD450112EN Wheelock Aft AS, MT, RSS, ET70 September 2020 Wall mount models Table 5. Specification and ordering information MrAgency Approvals Model Number Finish Kit Order Code UL ULC CSFM FM Strobe RSSWP-2475W-FR Red 9013 X X X X RSSWP-2475W-FW 4µ7;4 White 3034 X X X X RSSWP-24MCWH-FA Red 5161 X X X -- RSSWP-24MCWH-FW White 5165 X X X - Audible strobe ASWP-2475W-FR Red 9012 X X X X ASWP-24MCWH-FR Red 5137 X X X — ASWP-24MCWH-FW White 5140 X X X Multilane strobe MTWP-2475W-FR Red 8420 X X X X MTWP-2475W-FW White 3112 X X X X MTWP-24MCWH-FR ' - 0+' Red 5132 X X X — MTWP-24MCWH-FW ' .-^P=,Y White 5134 X X X — MTWP-2475W-FR KIT Ry- Red Includes IOB-R backbox 9082 X X X X MTWP-2475W-FW KIT '" White Includes 10B-W backbox 9083 X X X X MTWP-2475W-NW KIT White Includes 10B-W backbox 9084 X X X X eaker strobe Red 9077 X X X ET7OWP-2475W-FW White 3179 X — X X ET7OWP-2475W-ALR Red 4480 X — X X ET7OWP-2475W-ALW White 4481 X — X X ET7OWP-24185W-FR Red 4885 X — X X ET7OWP-24185W-FW White 4891 X — X X EF70WP-2475W-FR KIT Red Includes 106-R backbox 9078 X — X X OWP-2475W-FW KIT White Includes 10B-W backbox 9079 X — X X OWP-24135W-NW White 1111 X — X X OWP-24135W-FR Red 4872 X — X X ET7OWP-24135W-FW White 4875 X — X X ET7OWP-24135W-ALW White 6407 X — X X Ceiling mount models Table 6. Specification and ordering information Agency Approvals Model Number Finish Kit Order Code UL ULC CSFM FM Strobe ASSWP-2475C-FR Red 4338 X X X X RSSWP-2475C-FW White 4446 X X X X RSSWP-24MCCH-FR L-- Red 5167 X X X — ASSWP-24MCCH-FW White 5187 X X X Audible strobe ASWP-2475C-FR F1H� „ Red 4251 X X X X ASWP-2475C-FW White 4502 X X X X ASWP-24MCCH-FR 10 Red 5149 X X X — ASWP-24MCCH-FW White 5157 X X X — Multitone strobe - MTWP-2475C-FA ' ' Red 4457 X X X X MTWP-2475C-FW FIR White 4458 X X X X MTWP-24MCCH-FR F Red 5102 X X X — MTWP-24MCCH-FW White 5122 X X X Speaker strobe ET7OWP-2475C-FR Red 4452 X — X X It OWP-2475C-FW White 4454 X — X X DWP-24177C-FR Red 4845 X — X X OWP-24177C-FW 11, ,- White 4859 X — X X ET7OWP-2475C-FR KIT Tt.. Red Includes IOB-R backbox 9080 X — X X ET7OWP-2475C-FW KIT \ White Includes I0B-W backbox 9081 X — X X ET7OWP-24115C-FR Red 4550 X — X X ET7OWWP-24115C-FW White 4732 X — X X ET7OWP-24115C-NW White 3552 X — X X 4 EATON www.eaton.com 6 Wheelock AH,AS, MT, RSS, ET70 Technical Data TD450112EN August 2020 Wall or ceiling mount models • Table 7. Specification and ordering information Agency Approvals Model Number Finish Order Code UL ULC CSFM FM Audible AH-24WP-R Red 7416 X X X X 1111 Horn MT-12/24-R Red 5023 X X X X MT-12/24-W White 5024 X X X X Speaker ET-1010-R ,=.4;. ,=-1 Red 3135 X Available X X ET-1010-W "it—^r". --? White 3137 X Available X X ! ,a-^r_ten•:. Mounting accessories Table 8. Ordering information Model Number Finish Order Coda Model Number Finish Order Code Backboxes Gasket kit 1.1X4C0 Red 5046 ""--> agg N/A 4486 I0B W O White 5047 Flush plates le WFPA-R Red 4698 WFPA-W White 4701 0, WPSBB-RC) Red 9751 WPSBB-W 0ar White 3033 WFP-R Red 4696 WFP-W White 4697 WPBB-R© Red 9014 WPBB-W O White 4692 Table 9. Mounting options WBB-R Red 2959 WBB-W11 White 2960 Surface Mount Flush Mount Exposed Mounting Options Conduit Concealed Conduit RSSWP Strobes WPSBB WPSBB+WP-KIT WFP ET70WPSpeakerStrobes 10B+WP-KIT WFP ASWP Horn Strobes WPBB WPBB+WP-KIT WFPA O 10B.WPSBB and WPBB models include weep holes and plug in the event that moisture may have AHWP Horns WBB — WFP entered the appliance. ET-1010 Speakers WBB — WFP MTWP Multitane Strobes 10B 10B+WP-KIT WFP • Multilane 10B 10B+WP-KIT WFP Note: Refer to Data Sheet TD450028EN for mounting options EATON www.eaton.com 5 I` Technical Data TD450112EN Wheelock AH, AS, MT, RSS, ET70 Effective September 2020 Architects and engineers specifications Illeneral Weatherproof notification appliances shall be UL listed for outdoor use.Weatherproof strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances)for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired).The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit,concealed conduit,or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes and Audibles Weatherproof strobe appliances shall be Wheelock RSSWP models or approved equals. The weatherproof strobes shall produce a mini- mum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of-40°F to 150°F(-40°C to 66°C)and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACE). Weatherproof audibles shall be Wheelock AH models or approved equals,and the weatherproof audible/strobe combinations shall be Wheelock ASWP models or approved equals. The weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464.The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized.The horns shall have at least 3 sound level settings. Horn/strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall Wheelock MT models or approved equals. The multitone horns shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone audible/strobe combinations shall have independent inputs for the audible and strobe. The strobes and Code 3 horns shall be able to be synchronized.The audibles shall be able to be coded when operated on a separate NAC. ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required.The strobes on MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC.When set to Code 3 Horn,the MT multitone audibles shall be able to be synchronized. Weatherproof Speakers and Speaker/Strobes speakers shall be Wheelock ET-1010 models or approved equals, and speaker strobes shall be ET7OWP or approved equals. eatherproof speakers and speaker strobes shall be UL listed for indoor/outdoor use under UL Standard 1480. All speakers shall provide .eatherproof ld selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construc- tion for extra protection and improved audibility. Speakers shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker strobes shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Sync Modules When synchronization of strobes or temporal code-3 audibles is required,the appliances shall be compatible with the Wheelock DSM sync modules,Wheelock power supplies or other manufacturers panels with built-in Wheelock patented sync protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock IOB,WBB,WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. � w 71 Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3-YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Eaton Life safety&mass notification solutions • 273 Branchport Ave. Long Branch,NJ 07740 Eaton.com/Lifesafetynotification ®2020 Eaton i All Rights Reserved T�N Printed in USA Eaton is a registered trademark. Publication No.TD450112EN All other trademarks are property Powering Business Worldwide September 2020 of their respective owners. ,„„ > SGW77 ( , _ j - HORN/STROBE ; LIGHT GUARD STY nTilltia In. c eelock Vss ��"Designing products that protect." E70 Series Speaker Strobe i DESCRIPTION The CHASE SECURITY WIRE ENCLOSURE has been designed N_ t „ to protect horns,strobe lights,and other devices against vandalism i •� j ,-� F, IM 1 or accidental damage. It is designed for Prisons,HUD Projects, f/ i i i p I.::'", Universities,Hotels,Parks, Schools,Hospitals and other public ■R'"a" . p. locations where both functionality and aesthetics count. " The wire enclosure provides for ease of installation and -- , ..v maintenance of equipment once installed. For over 30 years Chase III. .\ wire products have been manufactured in a variety of sizes,styles `�t :::::,..:., L11d distribution. 1 Ccations. /` FEATURES a- -,11.1111111111 ` MAIM 1111110641 IMAM 1 • Constructed of 7-gauge(.177 in diameter)steel wire. 0 i i . • Welded at all points for strength. °' 'Ll i • Provided with four wire-formed eyelets for a solid installation. I Y ° I • Stock Finish:Nickel-plated coating.Custom models available in µ White polyester or red polyester coating. I! o • Dimensions I.D.7"x 7"x 4"deep. 1 ■ f IRE i: • Easy to install. t� mum um y • Unit can be provided with electrical provisions for conduit pipes `�- =-* of all sizes. ♦ Chase custom designs and builds to your specifications. Guard pictured with Wheelock ACCESSORIES E70 Series Speaker Strobe • Matching custom service plates available for wall or conduit applications. Chase Security Systems,Inc.,an MBE Enterprise,draws from over 30 years of experience selling to the Fire, Security, Computer,Sound,Food Processing,Forestry, Communications and Telecommunications industries. Many of our signature products are now being produced by tea- other manufacturers but our wire enclosures are still the product of choice for their strength. P.O.Box 30179,Chicago,IL 60630, Phone 773.775.7148,Fax 773.594.0078 www.chasesec.com ©2006 Chase Security Systems,Inc. Made with Pride in the U.S.A. Due to changes in industry,exact product dimensions and features may differ slightly from above.