Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
W52o2 t-cam OFFICE COPY R�gSQQ,� RECEIVED •iw. LT: Gi f Y Ur ita :r'SL7 3UIL,DING DIVISION NookWYATT FIRE PROTECTION , INC. 9095 S.W. Burnham Tigard. OR 97223 PELOTON 95 -8-5- SW WASHINGTON SQUARE RD, SPACE R05 TIGARD, OR 97223 FIRE PROTECTION EQUIPMENT SUBMITTAL tyco Worldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers "'° Description described herein must be installed and maintained in compliance with this doc- .,. The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable "' •. Upright(TY313)and Pendent(TY323) standards of the National Fire Protec- Sprinklers described in this data sheet tion Association,in addition to the stan- i are quick response,standard coverage, dards of any other authorities having S decorative 3 mm glass bulb-type spray jurisdiction.Failure to do so may impair ` sprinklers designed for use in light or the performance of these devices. ordinary hazard,commercial occupan- cies such as banks, hotels,and shop- The owner is responsible for maintain- ping malls. ing their fire protection system and devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble, is intended for use in areas with a any questions. finished ceiling.This recessed pendent sprinkler uses one of the following: Sprinkler -. ,4441114. • A two-piece Style 15 Recessed Escutcheon with recessed adjust- Identification meet up to 5/8 inch (15,9 mm)from the flush pendent position. Number (SIN) • A two-piece Style 20 Recessed Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2*NPT ment up to 1/2 inch (12,7 mm) from TY323 Pendent 5.6K, 1/2*NPT "*. the flush pendent position. The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) 175°F(79°C) Intermediate level versions of Series Approvals 200°F(93°C) TY-FRB Sprinklers are described in UL and C-UL Listed 286°F(141°C) Technical Data Sheet TFP357. Sprin- FM, LPCB,and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi(12.1 bar) Frame Bronze 250 psi(17.2 bar)* Button Brass/Copper *The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories, Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psi1/2(80,6 LPM/bar1/2) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector, can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* - / Cf„` 5 r�� 7/16' Y �_ 1,1 mm) iur Cia 4 NOMINAL � 2° [ - I MAKE-IN (50,82 mm _ IN VI W t (50,8 mm) + (34,9 mm) 3 / WRENCH I, (0r FLATS 1 7. 1/2"NPT** DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright (TY313)and Pendent(TY323) (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to General Instructions FIGURE 2 activate and water to flow. Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- kler held horizontally, a small air WRENCH bub- Criteria ble should be present. The diameter of the air bubble is approximately 1/16 RECESS The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and Upright(TY313) and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) Sprinklers are intended for fire protec- temperature ratings. Oriii. tion systems designed in accordance A leak-tight 1/2 inch NPT sprinkler joint with the standard installation rules rec- ognized by the applicable Listing or should be obtained by applying a min- Approval agency (such as, UL Listing imum to maximum torque of 7 to 14 is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels %r 13, and FM Approval is based on the of torque can distort the sprinkler Inlet requirements of FM's Loss Prevention with consequent leakage or impairment PUSH WRENCH of the sprinkler. Data Sheets).Only the Style 15 or Style IN TO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for ENGAGEMENT for recessed pendent installations, insufficient adjustment in the Escutch- WITHSPRINKLER AREA eon Plate by under-or over-tightening WRENCHING the sprinkler. Re-adjust the position of FIGURE 3 the sprinkler fitting to suit. _ W-TYPE 7 RECESSED SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the pendent position.Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3.Tighten the sprinkler into the 2-7/8" DIA. sprinkler fitting using only the W-Type (73,0 mm) 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1,apply the W-Type 6 2-1/4" DIA. Sprinkler Wrench to the wrench flats. FACE OF ~ (57,2 mm) Torque sprinklers 7 to 14 ft.-Ibs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 min) Recessed Pendent Sprinklers i ` _, FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" Sprinklers must be installed in accor- (9,5±7,9 mm) Z 71 a 'V % + 1- dance with the following instructions. f ,, Step A.After installing the Style 15 or MOUNTING '�� 1/8" i 1 Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm) kler threads, and with pipe-thread sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE 3/4"(19,1 min) sprinkler fitting. FIGURE 4 Step B.Tighten the sprinkler into the SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) sprinkler fitting using only the W-Type WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 7 Recessed Sprinkler Wrench (Figure RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8" DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Ste C.After ceilin (57, installation and fin- SPRINKLER 2"DIA. ishing,slide on the Style 15 or Style 20 FITTING (57,2 min) Closure over the Series TY-FRB Sprin- 5/16±1/4" kler and push the Closure over the (7,9±6,4 mm) 1!2 (12,7 min) Mounting Plate until its flange comes in + - FLUSH 1 contact with the ceiling. n •, _ �l . ,T Care and t M1/8" i Maintenance SOURFACE UNTING ��� (3,2 min) The TYCO Series TY-FRB,5.6 K-factor, Upright(TY313) and Pendent(TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outer piece of an if they cannot be completely cleaned Automatic sprinkler systems are rec- escutcheon, which is used to cover by wiping the sprinkler with a cloth or ommended to be inspected, tested, _ a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ cleaned by means of gently dusting slippage,or the like,must be replaced. with a feather duster;otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad- cracked bulb or that has lost liquid from vertent operation may result. its bulb. (Ref. Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) PURE WHITE(RAL9010)** 155 155°F(68°C) 370 5.6K UPRIGHT(1/2"NPT) TY313 3 POLYESTER L 371 5.6K PENDENT(1/2"NPT) TY323 q SIGNAPOLYIESTERL9003) 175 175°F(79°C) .Use suffix-I"for ISO 7-1 connection; 9 CHROME PLATED 200 200°F(93°C) for example.77-370-4-175-I "Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order, indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6,Quick Response,(specify)tem- perature rating, (specify) finish, P/N (specify,refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify*)finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with(specify*)finish, P/N(specify") *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, • P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. tIf co TEFLON is trademark of The DuPont Corporation, " Fire Protection Products Worldwide orldwide I www.tyco-fire.com tL1,Ci Contacts Series RFII — 5.6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General The Series RFII Sprinklers are shipped with a Disposable Protective Cap.The Description Protective Cap is temporarily removed p during installation and replaced to help The TYCO Series RFII 5.6 K-factor, protect the sprinkler during ceiling "Royal Flush II" Concealed Pendent installation or finish.The tip of the Pro- ; tective Cap can be used to mark the Sprinklers Quick Response (3-mm , bulb) and Standard Response (5-mm center of the ceiling hole into plaster 1 board or ceiling tiles by gently pushing bulb), are decorative sprinklers fea the ceiling product against the Pro- "'--�"= ., Luring a flat cover plate designed to tective Cap. When ceiling installa- conceal the sprinkler.These sprinklers tion is complete,the Protective Cap is are optimal for architecturally c removed and the Cover Plate/Retainer office tive areas such as hotel lobbies,office Assembly is installed. buildings,churches,and restaurants. Each sprinkler includes a Cover Plate/ As an option,the Series RFII Standard Retainer Assembly and a Sprinkler/ Response(5-mm bulb)"Royal Flush II" Support Cup Assembly. The separa- Concealed Pendent Sprinklers can be ble, two-piece assembly design pro- fitted with a silicone Air and Dust Seal. Technical vides the following benefits: (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas Data • Allows installation of the sprinklers where it is desirable to prevent air and and pressure testing of the fire pro- dust from the area above the ceiling to Sprinkler Approvals tection system prior to installation of pass through the cover plate. Approvals apply only to the service a suspended ceiling or application of conditions indicated in the Design Criteria the finish coating to a fixed ceiling. NOTICE section. • Permits the removal of suspended The Series RFII Concealed Pendent • TY3531 (3 mm Bulb)is UL Listed,C-UL ceiling panels for access to building Sprinklers described herein must be Listed and NYC Approved(MEA 353- service equipment without having installed and maintained in compliance 01-E)as Quick Response. to first shut down the fire protection with this document and with the appl- • TY3531 (3 mm Bulb)is VdS Approved system and remove sprinklers. cable standards of the NATIONAL FIRE (Certificate No.G4090007). • Provides for 1/2 in. (12,7 mm)of ver- PROTECTION ASSOCIATION (NFPA), • TY3531 (3 mm Bulb)is FM and in addition to the standards of any tical adjustment to allow a measure LPCB Approved(Ref.No.094a/10)as of flexibility in determining the length authorities having jurisdiction. Failure Standard Response. of fixed piping to cut for the sprinkler to do so may impair the performance drops. of these devices. Note:FM and LPCB concealed sprinklers�orquick o not prove The owner is responsible for maintain- response. ing their fire protection system and devices in proper operating condition. • TY3551 (5 mm Bulb)is UL Listed,C-UL The installing contractor or sprinkler Listed,FM Approved,LPCB Approved manufacturer should be contacted with (Ref.No.094a/9),and NYC Approved any questions. (MEA 353-01-E)as Standard Response. IMPORTANT Approvals for Air and Dust Seal Refer to Technical Data Sheet Sprinkler UL and C-UL Listed for use with the RFII TFP2300 for warnings pertaining to Standard Response Concealed Sprinkler regulatory and health information. Identification (TY3551) Always refer to Technical Data Maximum Working Pressure Number (SIN) Sheet TFP700 for the "INSTALLERMaximum 250 psi(17,3 bar)by UL, WARNING"that provides cautions C-UL,and NYC with respect to handling and instal- TY3531 - 3 mm bulb Maximum 175 psi(12,1 bar)by FM,VdS, lation of sprinkler systems and corn- TY3551 — 5 mm bulb and LPCB ponents. Improper handling and Temperature Rating installation can permanently damage 155°F(68°C)Sprinkler with a sprinkler system or its compo- 139°F(59°C)Cover Plate nents and cause the sprinkler to fail to operate in a fire situation or cause 200°F(93°C)Sprinkler with it to operate prematurely. 165°F(74°C)Cover Plate Page 1 of 4 SEPTEMBER 2018 TFP181 TFP181 Page 2 of 4 Discharge Coefficient 1/2" NPT SEALING K.5.6 GPM/psi112(80,6 LPM/bar12) ASSEMBLY Adjustment 1/2 inch(12,7 mm) Finishes FRAME See the Ordering Procedure section ` CAP Physical Characteristics Frame Bronze Support Cup Plated Steel SUPPORT Guide Pins Stainless Steel CUP WITH BULB . Deflector Bronze ROLL FORMED Compression Screw Brass THREADS Bulb Glass Cap Bronze or Copper - Sealing Assembly..Beryllium Nickel w/TEFLON _ COMPRESSION Cover Plate Brass _ f( SCREW Retainer Brass GUIDE - (]{) Ejection Spring Stainless Steel PINS(2) 1_ ' Design DEFLECTO(DROPP DR Criteria DEFLECTOR�� lI `r i POSITION) The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent I SPRINKLER/SUPPORT CUP Sprinklers are intended for fire protec- ASSEMBLY tion systems designed in accordance I I with the standard installation rules THREAD INTO I RETAINER recognized by the applicable Listing SUPPORT ) I WITH THREAD or Approval agency; for example, UL CUP UNTIL O O DIMPLES Listing is based on NFPA 13 and VdS MOUNTING Approval is based on the CEA 4001. SURFACE IS EJECTION FLUSH WITH SPRING For more information on LPCB and VdS CEILING Approvals,contact Johnson Controlss at the following office: __ Enschede, Netherlands ��_ , L. Telephone:31-53-428-4444 / Fax:31-53-428-3377 SOLDER J ----— COVER The Series RFII Concealed Pendent TABS(3) COVER PLATE/RETAINER PLATE Sprinklers are only listed and approved ASSEMBLY with the Series RFII Concealed Cover FIGURE 1 Plates having a factory applied finish. MODEL RFII CONCEALED SPRINKLER ASSEMBLY NOTICE Do not use the Series RFII in applica- Installation Do not attempt to compensate for tions where the air pressure above the insufficient adjustment in the Sprinkler ceiling is greater than that below.Down The TYCO Series RFII 5.6 K-factor, by under-or over-tightening the Sprin- drafts through the Sprinkler/Support "Royal Flush II" Concealed Pendent kler/Support Cup Assembly.Re-adjust Cup Assembly can delay sprinkler Sprinklers must be installed in accor- the position of the sprinkler fitting to operation in a fire situation. dance with this section. suit. Operation General Instructions Step 1. Install the sprinkler only in the p Do not install any bulb-type sprinkler pendent position with the center-line if the bulb is cracked or there is a loss of the sprinkler perpendicular to the When exposed to heat from a fire,the mounting surface. Cover Plate, normally soldered to the of liquid from the bulb.With the sprin- Retainer 2.Remove the Protective Cap. Retainer at three points, falls away to kler held horizontally,a small air bubble - expose the Sprinkler/Support Cup should be present.The diameter of the Step 3. With pipe thread sealant Assembly. air bubble is approximately 1/16 inch applied the the r intoreads, hand- the sprinkler (1,6 mm)for the 155°F(68°C)and 3/32 tighten. P The Deflector — supported by the inch(2,4 mm)for the 200°F(93°C)tern- fitting. Guide Pins — then drops down to its perature ratings. Step 4. Wrench-tighten the sprinkler operational position. A leak-tight 1/2 inch NPT sprinkler using only the RFII Sprinkler Wrench. The glass bulb contains a fluid that joint should be obtained by applying a (Refer to Figure 3.) Apply the RFII expands when exposed to heat.When minimum to maximum torque of 7 to 14 Sprinkler Wrench to the Sprinkler as the rated temperature is reached, the ft.-lbs. (9,5 to 19,0 Nm). Higher levels shown in Figure 3. fluid expands sufficiently to shatter the of torque can distort the sprinkler Inlet glass bulb,activating the sprinkler and with consequent leakage or impairment allowing water to flow. of the sprinkler. TFP181 Page 3 of 4 FACE OF CLEARANCE HOLE CLEARANCE SPRINKLER - DIAMETER HOLE FITTING DIMENSION C ' SPRINKLER ib'_ i • SUPPORT CUP r '_ ASSEMBLY iMMI 1111 I 11 1/2'(12,7 mm) THREADED ) AI owl i'V • D ADJUSTMENT tt,iI,iu_p,,_ /%FACEOF CEILING, • • • RETAINING RING MOUNTINGSURFACE FIGURE 4 , � DISPOSABLE PROTECTIVE CAP --� , Step 5. Replace the Protective Cap by pushing it upwards until it bottoms L L out against the Support Cup. (Refer r=� - T to Figure 4.)The Protective Cap helps 3/16"to 11/16' MANUFACTURER DEFLECTOR COVER PLATE prevent damage to the Deflector and (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER Arms during ceiling installation and/or REFERENCE 3/32"(2,4 mm) POSITION ASSEMBLY finish.You can also use the Protective Cap to locate the center of the clear- COVER PLATE COVER PLATE ance hole by gently pushing the ceiling -PROFILE DEPTH DIAMETER material up against the center point of DIMENSION B DIMENSION A the Protective Cap. A:3-1/4 inches(82,6 mm) C:2-3/8 to 2-5/8 inches(60,3 to 66,7 mm) NOTICE B:3/16 inches(4,8 mm) D: 1-3/4 to 2-1/4 inches(44,5 to 57,2 mm) As long as the Protective Cap remains in place,the system is considered "Out FIGURE 2 of Service". SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS Step 6. After the ceiling has been completed with the 2-1/2 in.(63,5 mm) diameter clearance hole and in prep- ---.-------- .—_------- aration for installing the Cover Plate/ Retainer Assembly,remove and discard i=l, FRAME l=l`_ the Protective Cap. Verify that the cj fl ARM % "1 Deflector moves up and down freely. If the Sprinkler is damaged and the �, Deflector does not move up and down SUPPORT - freely, replace the entire Sprinkler. - ' ' Do not attempt to modify or repair a IIdamaged sprinkler. ■I 9�„�,��� Step 7. When installing an Air and �`/ Dust Seal, refer to Figure 5;otherwise, O proceed to Step 8. To attach the Air 7/8" (23 mm) and Dust Seal, verify the angle of the SQUARE outside edge of the seal is oriented N- according to Figure 5.Start the edge of the Retainer in the grooved slot of the J ALIGN J =. Air and Dust Seal and continue around ARROWS WITH I I \ the retainer until the entire Air and Dust FRAME ARMS L. Seal is engaged. Ii arl � ACCEPTS \ \\ 1/2"SOCKET \ : DRIVE FIGURE 3 RFII SPRINKLER WRENCH TFP181 Page 4 of 4 Step 8. Screw on the Cover Plate/ SUPPORT SPRINKLER FACE OF ORIENT Retainer Assembly until the Retainer CUP CEILING J—SEAL (shown in Figure 2)or the Air and Dust BEVEL AS Seal (shown in Figure 5) contacts the SHOWN ceiling.Do not continue to screw on the COVER Cover Plate/Retainer Assembly so that PLATE it lifts a ceiling panel out of its normal RETAINER position. If you cannot engage the ASSEMBLY Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer Assembly suf- ficiently to contact the ceiling,you must AIR reposition the Sprinkler Fitting. 7:....,../ AND DUST LIP OF COVER SEAL - Care and RETAINER PLATE FIGURE 5 Maintenance OPTIONAL AIR AND DUST SEAL FOR SERIES RFII(TY3551) The TYCO Series RFII 5.6 K-factor, Care must be exercised to avoid "Royal Flush II" Concealed Pendent damage to the sprinklers - before, Ordering Sprinklers must be maintained and during, and after installation. Sprin- serviced in accordance with this klers damaged by dropping, striking, Procedure section. wrench twist/slippage,or the like,must Before closing a fire protection system be replaced. Also, replace any sprin- Contact your When local distributor for main control valve for maintenance kler that has a cracked bulb or that has availability. placing an order, product indicate the full productt name. work on the fire protection system lost liquid from its bulb. (Ref. Installa- that it controls, obtain permission to tion Section.) Sprinkler/Support Cup Assembly shut down the affected fire protection Exercise care to avoid damage to sprin- Specify: Series RFII (specify SIN), system from the proper authorities klers before, during, and after instal- K=5.6, "Royal Flush II"Pendent Sprin- and notify all personnel who may be lation. Replace sprinklers damaged klers(specify)temperature rating,P/NA affected by this action. by dropping, striking, wrench twist- (specify): Absence of the Cover Plate/Retainer ing, wrench slipping, or the like. Also, 1550F168°C) 2000FI93°CJ Assembly can delay sprinkler opera- replace any sprinkler that has a cracked TY3531 51-792-1-155 51-792-1-200 tion in a fire situation. bulb or that has lost liquid from its bulb. TY3551 51-790-1-155 51-790-1-200 (Refer to the Installation section.) When properly installed, there is a - Use Suffix"I"for ISO 7-1 connection;for example, nominal 3/32 in. (2,4 mm) air gap If you must remove a sprinkler, do not 51-792-1-155-I between the lip of the Cover Plate and reinstall it or a replacement without Separately Ordered Cover Plate/ the ceiling,as shown in Figure 2. reinstalling the Cover Plate/Retainer Retainer Assembly: Assembly. If a Cover Plate/Retainer Specify: (temperature rating from This air gap is necessary for proper Assembly becomes dislodged during operation of the sprinkler. If the ceiling service,replace it immediately. below) Series RFII Concealed Cover requires repainting after sprinkler Plate with (finish),P/N (specify). The owner is responsible for the installation, ensure that the new paint inspection,testing,and maintenance of 139°F(59°C)(a) 165°F(74°C)(b) Grey white does not seal off any of the air gap. their fire protection system and devices (RAL9002) 56-792-0-135 56-792-0-165 Do not pull the Cover Plate relative to in compliance with this document, as Brass 56-792-1-135 56-792-1-165 the Enclosure.Separation may result. well as with the applicable standards Pure White(c) are found to of the NATIONAL FIRE PROTECTION (RAL9010) 56-792-3-135 56-792-3-165 Sprinklersiting which signs bef ASSOCIATION,for example, NFPA 25, Signal White leaking or must be exhibiting visible in addition to the standards of any other (RAL9003) 56-792-4-135 56-792-4-165 authorities having jurisdiction.Contact Jet Black Automatic sprinklers must never be the installing contractor or sprinkler (RAL9005) 56-792-6-135 59-792-6-165 painted, plated, coated, or other- manufacturer regarding any questions. Brush Chromeed 56-792.8-135 56-792-8-165 wise altered after leaving the factory. Automatic sprinkler systems should be Chrome 56-792-9-135 56-792-9-165 - Modified sprinklers must be replaced. inspected,tested,and maintained by a Custom 56-792-X-135 56-792-X-165 Sprinklers that have been exposed to qualified Inspection Service in accor- corrosive products of combustion, but dance with local requirements and/or (a) For use with 155°F(68°C)sprinklers. - have not operated,should be replaced national code. (b) For use with 200°F(93°C)sprinklers. if they cannot be completely cleaned (c) Eastern Hemisphere sales only. by wiping the sprinkler with a cloth or Limited Sprinkler Wrench by brushing it with a soft bristle brush. Specify: RFII Sprinkler Wrench, Warranty P/N 56-000-1-075 For warranty terms and conditions,visit Air and Dust Seal www.tyco-fire.com. Specify:Air and Dust Seal, P/N 56-908-1-001 1400 Pennbrook Parkway,Lansdale,PA 19448!Telephone♦1-215-382-0700 /' % c2010 Johnson Controls.All rights reserved.All specllicadons and other information shown were current as of document revision date and ere subject to change without notice. Johnson A' �j NATIONAL FIRE PROTECTION ASSOCIATION and NFPAa,e registered tradema,ks at Natural Fee Pm,eeeon Assoca4°n', Controls TEFLON is a registered trademark of DuPont Vico Worldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB — 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General tamed when exposed to corrosive at- • mospheres. Although corrosion resis- Descri tion tant coated sprinklers have passed the p standard corrosion tests of the appli- The Series TY-FRB, 5.6 K-factor, Hor- cable approval agencies,the testing is a>';; izontal and Vertical Sidewall Sprin- not representative of all possible cor- klers described in this data sheet rosive atmospheres. Consequently, it ^ + *4; pi, are quick response -standard cover- is recommended that the end user be I. age, decorative 3 mm glass bulb type consulted with respect to the suitabil- spray sprinklers designed for use in ity of these coatings for any given cor- , light and ordinary hazard, commer- rosive environment.The effects of am- cial occupancies such as banks, ho- bient temperature, concentration of tels,shopping malls,etc.They are de- chemicals, and gas/chemical velocity, signed for installation along a wall or should be considered, as a minimum, the side of a beam and just beneath a along with the corrosive nature of the smooth ceiling.Sidewall sprinklers are chemical to which the sprinklers will commonly used instead of pendent or be exposed. upright sprinklers due to aesthetics or building construction considerations, NOTICE where piping across the ceiling is not The Series TY-FRB Sprinklers de- desirable. scribed herein must be installed and ` The recessed version of the Series maintained in compliance with this / ,' TY-FRB Horizontal Sidewall Sprin- document, as well as with the appli- cablekler is intended for use in areas with standards of the National Fire a finished wall. It uses a two-piece Protection Association, in addition to Style 10 Recessed Escutcheon with the standards of any other authorities ;* 1/2 inch(12,7 mm)of recessed adjust- having jurisdiction. Failure to do so ment or up to 3/4 inch(19,1 mm)of to- may impair the performance of these tal adjustment from the flush sidewall devices. position, or a two-piece Style 20 Re- The owner is responsible for main- cessed Escutcheon with 1/4 inch (6,4 taming their fire protection system mm) of recessed adjustment or up to and devices in proper operating con- 1/2 inch (12,7 mm) of total adjustment dition. Contact the installing contrac- from the flush sidewall position. The tor or sprinkler manufacturer with any adjustment provided by the Recessed questions. Technical Escutcheon reduces the accuracy to which the fixed pipe nipples to the Sprinkler Data sprinklers must be cut. Corrosion resistant coatings, where Identification Approvals applicable, are utilized to extend the UL and C-UL Listed. life of copper alloy sprinklers beyond Numbers FM, LPCB,and NYC Approved. that which would otherwise be ob- (Refer to Table A for complete approv- TY3331 Horizontal al information including corrosion re- TY3431 Vertical sistant status.) IMPORTANT Always refer to Technical Data Maximum Working Pressure Sheet TFP700 for the "INSTALLER Refer to Table B. WARNING" that provides cau- Discharge Coefficient Lions with respect to handling K=5.6 GPM/psi1/2(80,6 LPM/bar112) and installation of sprinkler sys- tems and components. Improp- Temperature Ratings er handling and installation can Refer to Table A. permanently damage a sprin- Finishes kler system or its components Sprinkler: Refer to Table C. and cause the sprinkler to fail Recessed Escutcheon:Signal or Pure to operate in a fire situation or cause White,Jet Black,Chrome Plated,or it to operate prematurely. Brass Plated. Page 1 of 6 FEBRUARY 2014 TFP176 TFP176 Page 2 of 6 1 - Frame DEFLECTOR Installation 2 - Button HAT 5 The Series TY-FRB,5.6 K-factor, Hori- 3 - Sealing zontal and Vertical Sidewall Sprinklers Assembly must be installed in accordance with 4 - Bulb this section. 5 - Compression Screw General Instructions 6 - Deflector* 6*/ 4 2 3 1 Do not install any bulb type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the • 9/16" WRENCH 1/2"** sprinkler held horizontally, a small air (14,3 mm) FLATS NPT bubble should be present. The diam- eter of the air bubble is approximately r/ i \ / 1/16 inch(1,6i mm)for the 135°F(57°C) to 3/32 inch (2,4 mm) for the 286°F -womb. (141°C)temperature ratings. •l �'�al A leak tight 1/2 inch NPT sprinkler joint ■ should be obtained with a torque of 7 1-13/16" _ 7/16" to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher (46,0 mm) (11,1 mm) levels of torque may distort the sprin- NOMINAL kler and cause leakage or impairment CENTERLINE MAKE-IN of the sprinkler. OF SPRINKLER WATERWAY Do not attempt to make-up for insuf- 1-1/2" y ficient adjustment in the escutcheon —(38,1 mm) plate by under-or over-tightening the *Temperature rating 2-3/16" sprinkler. Readjust the position of the is indicated on - sprinkler fitting to suit. Deflector. (55,6 mm) ESCUTCHEON Series TY-FRB Horizontal and STYLE I — PLATE SEATING Vertical Sidewall Sprinkler ** Pipe thread 10 or 20 SURFACE Installation ISO 7-1 can be ESCUTCHEON connections per RECESSED The Series TY-FRB Horizontal and provided on ' � � Vertical Sidewall Sprinklers must be special request. installed in accordance with the fol- 2-7/8"mIAm) it'd 'llllllllllll I Selowpg.nsorizoons. DIA. r IIII Step 1. Horizontal sidewall sprinklers (73,0 I are to be installed in the horizontal po- sition with their centerline of waterway perpendicular to the back wall and parallel to the ceiling.The word"TOP" on the Deflector is to face towards the ceiling. Vertical sidewall sprinklers are to be FIGURE 1 installed in the pendent or upright po- 5.6 K-FACTOR QUICK RESPONSE sition with the arrow on the Deflector SERIES TY-FRB HORIZONTAL SIDEWALL(TY3331)SPRINKLERS pointing away from the wall. Sep 2. nt ap- Physical Characteristics pli toedtheth pipe thripeeads, handread tighten ghten Frame Bronze Design the sprinkler into the sprinkler fitting. Button Brass/CopperSealing Assembly Beryllium Nickel WIStep Criteria Ste p 3. Tighten the sprinkler into the TEFLON sprinkler fitting using only the W-Type Bulb Glass The Series TY-FRB,5.6 K-factor,Hori- 6 Sprinkler Wrench (Ref. Figure 5), Compression Screw Bronze zontal and Vertical Sidewall Sprinklers With reference to Figure 1 or 2,the W- HSW Deflector Bronze are intended for fire protection sys- Type 6 Sprinkler Wrench is to be ap- VSW Deflector Copper tems designed in accordance with the plied to the wrench flats. standard installation rules recognized Operation by the applicable Listing or Approval agency (e.g., UL Listing is based on The glass bulb contains a fluid which the requirements of NFPA 13, and FM expands when exposed to heat.When Approval is based on the requirements the rated temperature is reached, the of FM's Loss Prevention Data Sheets). fluid expands sufficiently to shatter Only the Style 10 or 20 Recessed Es- the glass bulb, allowing the sprinkler cutcheon, as applicable, is to be used to activate and water to flow. for recessed horizontal installations. TFP176 Page 3 of 6 Series TY-FRB Recessed Horizontal Sidewall Sprinkler *Temperature ** Pipe thread 1 - Frame 4 - Bulb 7 - Ejection Installation rating is connections 2 - Button 5 - Compression Spring indicated on per ISO 7-1 can 3 - Sealing Screw The Series TY-FRB Recessed Hori- Deflector. be provided on Assembly 6 - Deflector* zontal Sidewall Sprinklers must be special request. installed in accordance with this section. ARROW MUST Ste A. Recessed horizontal sidewall POINT AND BYE �� P 7/16" FROM AND BE sprinklers are to be installed in the ESCUTCHEON (11,1 mm) PERPENDICULAR O horizontal position with their center- PLATE SEATING NOMINAL TO THE BACK line of waterway perpendicular to the SURFACE 1/2 ** MAKE-IN WALL SURFACE I back wall and parallel to the ceiling. NPT The word "TOP"on the Deflector is to 6* face towards the ceiling. 1-�i�— Step B.After installing the Style 10 or ral .4. FLOW b 5 20 Mounting Plate ov hr the sprinkler f ' threads, hand tighten the sprinkler into 2-3/16" \ 2_3/16� 4 the sprinkler fitting. (55,6 mm) (55,6 mm) Step C. Tighten the sprinkler into the 1-1/2" / II z2 sprinkler fitting using only the W-Type (36,1 mm) WRENCH 7 Recessed Sprinkler Wrench (Ref. FLATS 7 3 Figure 6). With reference to Figure + 1, the W-Type 7 Recessed Sprinkler ' 1 Wrench is to be applied to the sprin- SHOWN SHOWN CROSS kler wrench flats. PENDENT UPRIGHT SECTION Step D. After the ceiling has been in- FIGURE 2 stalled or the finish coat has been ap- 5.6 K-FACTOR QUICK RESPONSE plied, slide on the Style 10 or 20 Clo- SERIES TY-FRB VERTICAL SIDEWALL(TY3431)SPRINKLERS sure over the Series TY-FRB Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- if they cannot be completely cleaned The owner is responsible for the in- tact with the ceiling. by wiping the sprinkler with a cloth or spection, testing, and maintenance by brushing it with a soft bristle brush. of their fire protection system and de- Care and Care must be exercised to avoid dam- vices in compliance with this docu- age to the sprinklers before, during, ment, as well as with the applicable Maintenance and after installation. Sprinklers dam- standards of the National Fire Pro- aged by dropping, striking, wrench ion Association (e.g., NFPA 25), in The Series TY-FRB,5.6 K-factor, Hori- twist/slippage, or the like, must be addition to the standards of any oth- zontal and Vertical Sidewall Sprinklers replaced. Also, replace any sprinkler er authorities having jurisdiction. The must be maintained and serviced in that has a cracked bulb or that has installing contractor or sprinkler man- accordance with this section. lost liquid from its bulb. (Ref. Installa- ufacturer should be contacted relative Before closing a fire protection sys- tion Section). to any questions. tern main control valve for mainte- The owner must assure that the sprin- It is recommended that automatic nance work on the fire protection sys- klers are not used for hanging any ob- sprinkler systems be inspected, test- tern that it controls,permission to shut jects and that the sprinklers are only ed, and maintained by a qualified In- down the affected fire protection sys- cleaned by means of gently dusting local spection Service in accordance with tern must be obtained from the prop- with a feather duster; otherwise, non- local requirements and/or national er authorities and all personnel who operation in the event of a fire or inad- codes. may be affected by this action must vertent operation may result. be notified. Frequent visual inspections are rec- Absence of an escutcheon, which is ommended to be initially performed • used to cover a clearance hole, may for corrosion resistant coated sprin- delay the time to sprinkler operation in klers, after the installation has been a fire situation. completed,to verify the integrity of the • Sprinklers that are found to be leaking corrosion resistant coating. Thereaf- or exhibiting visible signs of corrosion ter, annual inspections per NFPA 25 must be replaced. should suffice; however, instead of in- specting from the floor level,a random Automatic sprinklers must never be sampling of close-up visual inspec- painted, plated, coated or other- tions should be made, so as to better wise altered after leaving the factory. determine the exact sprinkler condi- Modified sprinklers must be replaced. tion and the long term integrity of the Sprinklers that have been exposed to corrosion resistant coating, as it may corrosive products of combustion, but be affected by the corrosive condi- have not operated,should be replaced tions present. TFP176 Page 4 of 6 5/8±1/4" (15,9±6,4 mm) MOUNTING FACE OF WRENCH RECESS SURFACE SPRINKLER (END"A" USED FOR FITTING 1/2"NPT MODELS) A FIGURE 5 CLOSURE - W TYPE 6 SPRINKLER WRENCH 2-7/8"DIA. SERIES (73,0 mm) TY-FRB 2-1/4"DIA. WRENCH • (57,2 mm) RECESS MOUNTING 1 PLATE - 1/8" 1111.11 (3,2 mm) 1-1/4"(31,8 mm) 3/4"(19,1 mm) PUSH WRENCH 3/4"(19,1 mm) 1/4"(6,4 mm) IN EMUNT ENGG AGGEMENT FIGURE 3 WITH SPRINKLER SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WRENCHING AREA WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT FIGURE 6 STYLE 10 RECESSED ESCUTCHEON W-TYPE 7 RECESSED SPRINKLER WRENCH 1/2±1/8" (12,7±3,2 mm) MOUNTING FACE OF SURFACE SPRINKLER FITTING A CLOSURE 2-7/8" DIA. SERIES (73,0 mm) TY-FRB 2-1/4" DIA. (57,2 mm) MOUNTING PLATE /1 1/8" (3,2 mm) 1-1/4"(31,8 mm) I 1/2"(12,7 mm) 1"(25,4 mm) 1/4"(6,4 mm) FIGURE 4 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFP176 Page 5 of 6 SPRINKLER FINISH(See Note 11) K TYPE TEMP. BULB NATURAL CHROME LIQUID BRASS PLATED POLYESTER*** LEAD COATED 135°F(57°C) Orange HORIZ. 155°F(68°C) Red SIDEWALL 175°F(79°C) Yellow 1,2, 3,4,9, 10 1,2,3,9 1,2,3,9 (TY3331) 200°F(93°C) Green 286°F(141°C) Blue 5.6 RECESSED 135°F(57°C) Orange 1/2" HORIZ. 155°F(68°C) Red NPT SIDEWALL 175°F(79°C) Yellow 1,2,4,9,10 1.2,9 N/A Figure 3 200°F(93°C) Green RECESSED 135°F(57°C) Orange HORIZ. 155°F(68°C) Red SIDEWALL 175°F(79°C) Yellow 1,2,3,4,9 N/A (TY3331)•• Figure 4 200°F(93°C) Green VERTICAL 135°F(57°C) Orange SIDEWALL 155°F(68°C) Red 5.6 (TY3431) 1/2" Installed 175°F(79°C) Yellow 5,6,7,8,9 5,6,7,9 NPT Pe or 200°F(93°C) Green Upright 286°F(141°C) Blue NOTES: 1. Listed by Underwriters Laboratories,Inc.(UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance. 2. Listed by Underwriters Laboratories Inc.for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007a/04)at a 4 to 6 inch(100 to 150 mm)top of deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 5. Listed by Underwriters Laboratories,Inc.as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 6. Listed by Underwriters Laboratories for use In Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 7. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies. 8. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06&007a/04)as Quick Response Sprinklers. 9. Approved by the City of New York under MEA 354-01-E. 10. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)at a 4 to 6 inch(100 to 150 mm)top of deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 11. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resis- tant Sprinklers.Where Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion Resistant Sprinklers. Installed with Style 10(1/2"NPT)3/4"Total Adjustment Recessed Escutcheon. **Installed with Style 20(1/2"NPT)1/2"Total Adjustment Recessed Escutcheon. ***Frame and deflector only. TABLE A LABORATORY LISTINGS AND APPROVALS TFP176 Page 6 of 6 SPRINKLER FINISH K TYPE NATURAL BRASS CHROME PLATED POLYESTER LEAD COATED HORIZONTAL SIDEWALL 250 PSI(17,2 BAR) (TY3331) Or 175PSI (12,1 BAR) 5.6 RECESSED HORIZ. 1/2 SIDEWALL(TY3331) (SEE NOTE 1) NPT VERTICAL SIDEWALL 175 PSI(12,1 BAR) (TY3431) NOTES: 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE B MAXIMUM WORKING PRESSURE P/N 57 - XXX - X - XXX I I SIN SPRINKLER TEMPERATURE FINISH RATINGS 378 HORIZONTAL SIDEWALL TY3331 1 NATURAL BRASS 135 135°F(57°C) 375 VERTICAL SIDEWALL TY3431 3 PURE WHITE(RAL9010)' 155 155°F(68°C) POLYESTER 4 SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER 5 JET BLACK(RAL9005)" 200 200°F(93°C) POLYESTER 7 LEAD COATED 286 286°F(141°C) 9 CHROME PLATED 'Eastern Hemisphere sales only. "Available in 155°F(68°C)or 200°F (93°C)temperature rating only. TABLE C PART NUMBER SELECTION SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS OrderingSprinkler Assemblies with NPT Recessed Escutcheon Thread Connections: Specify:Style(10 or 20)Recessed Es- Procedure Specify: Series TY-FRB (specify SIN), cutcheon with (specify`) finish, P/N (specify K-factor), (specify) Horizontal (specify*). Contact your local distributor for avail- Sidewall or Vertical Sidewall Sprinkler, Refer to Technical Data Sheet TFP770 ability. When placing an order, indi- Standard Response, Standard Coy- cate the full product name and Part erage, (specify) temperature rating, Sprinkler Wrench Number(P/N). (specify) finish or coating, P/N (spec- Specify: W-Type 6 Sprinkler Wrench, ify from Table C) P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2013 Tyco Fire Products,LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS NOMINAL PIPE SIZE(in) WEIGHT(Ibs/ft) I.D. (in) BUNDLE SIZE 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS NOMINAL PIPE SIZE (in) SCHEDULE 40 EDDYTHREAD 40 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 • 2 1.00 1.00 Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems Che elarkd, O 6ad 3 For additional information, c �� �w` (��rLty Chesterfeld MO 017 contact your salesperson today at A II BULL MOOSE TUBE COMPANY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED FAX: (636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 it> A LPG company e-mairsales@bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 Ductile Iron Threaded Fitting))) SSA T ]Y }h kt B wsL x 3 SMITH COOPER® INTERNATIONAL Ductile Iron Threaded Fittings Specifications • 4* branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP C el US • Ductile iron castings conform to ASTM A536 LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 11:; • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings 20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 -.v i Ductile Iron Fittings - Class 300 UL/FM ( Quarrm PLUS calus APPROVED Fig. 35E 3- 90°Elbow LISTED A Size A Packing Weight Part Number •..,. in in Inner Master lb �•i_ 2 35E 3004 13 100 200 0.2a `�i 3,4 35E 3006 1.31 70 140 0.3 %�•,i I p A I 35C 3010 1.50 40 80 0.5 �I.111!6 1-1/4 35E 3012 1.75 25 50 0.8 • le 1-1/2 35L301.1 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 • Fig. 35RE3- 90°Reducing Elbow SB ) Size Part Number A B Packing Weight .yam in in in Inner Master lb •py 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 , s 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 A 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 gild1-1/4 x 1/2 35RE3012004 1,34 1.53 35 70 0.5 1-1/4x3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 353E3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 +'":1:` 2x1-1/4 35RE3020012 1.90 2.10 12 24 1.3 ,,.f 2x 1-1/2 350E3020014 2,02 2.16 IC 20 1.5 U 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 350E3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow Size A Packing Weight Part Number C A in in Inner Master lb " 1/2 35F 3004 0.88 150 300 0.2 ���D�A 3/4 35F 3006 0.98 80 160 0.3 •�' 1 35F 3010 1,13 40 BC 0.5 �•i 1-1/4 35F 3012 1.29 25 50 0.7 ��40 A 1-1/2 35f 3014 1.44 20 40 1.0 11 T ,. 9 10 20 1,6 i 1 2 35F 3020 6 2-1/2 35F 3024 1,95 4 8 2.7 Fig. 35T3 - Tee Size A Packing Weight __ Part Number in in Inner Master lb llTa A0 1/23513004 1.13801600.3 3/435T 3006 1.31 3060 0.5 rja I 1 3513010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 A A ' 1.1/2 351 3014 1.94 10 20 1 5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com /. )�t�` Ductile Iron Fittings- Class 300 UL/FM ?...[ JALiI??LU:._.1 c o us APPROVED Fig. 35RT3-Reducing Tee LISTED Size A B C Packing Weight Part Number Ipi n in n in Inner Master lb (✓ 3/4x 1/2 3500 I3006004 1.20 1.20 1.22 60 120 0.4 t x 1/2 35813010004 1.26 1.26 1.36 30 60 0.6 -��- - 1 x 1/2 x 1 35813010004010 1.50 1.36 1.50 30 60 0.6 1x 3!4 35RT3010006 1.38 1.38 1.45 25 50 0.6 I-I t 1 x 3/4 x 3/4 35073010006006 1.38 1.31 1.45 35 70 0.6 B A 1 x 3/4 xi 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35873012004 1.34 1.34 1 53 20 40 0.8 • 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4x3/4 35R73012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35873012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35813012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 351173014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 3/4 3591)3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 351973014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1 1/2 x 1 x 1/2 359130114010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35973014010006 1.50 1.44 1.75 16 32 0.9 1 1/2 x 1 x 1 35973014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35973014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 112 359T3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1,94 1.88 1.94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35873020006 1.60 1.60 1.97 10 20 1.6 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 357)73020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35973020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 B 16 2.1 2 x 1-1/2 x 1/2 35813020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35973020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2x 1-1/2x 1-1/2 3517T3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3-Bull Head Tee Size A B C Packing Weight ■■�� C in Part Number in n in Inner Master lb x 1 35873006010 1.45 1.45 1.37 30 60 0 i� 1 x 1-1/4 35813010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35873010014 1.80 1.80 1.65 15 30 0.6 1.0 A B 1-1/4 x 1 x 1-1/2 35B13012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35873014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35873014020 2.16 2.16 2.02 8 16 1.8 SMIITII-CO PER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 112 ,,,`;:; ~i712f�i 1lriMD,01111711161Mtflillt19210 QUAwM?Lit, C ® US APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Part Number A Packing Weight Fillin in Inner Master IC 1/2 3/4 35063004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 ;. 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0 7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 22 Fig. 35RC3 -Hex Reducing Coupling a _ir Size Part Number A Packing Weight p in in lb /AI � A 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x 3/4 35RC3010006 1.69 60 120 0.4 �,�'� - 1-1/4x3/4 35R03012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2 Inner Master 81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight B in in Inner Master lb t ) 1 x 1/2 35HB3010004 1.06 180 360 0.2 IA 1 x 3/4 35HB3010006 1.06 180 360 0.1 1 r 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 1-1/2 x 1 35H63014010 1.25 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 70 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 -Square Head Plug l Size Part Number A Packing Weight in in Inner Master lb 1/2 35363004 0-94 600 1200 0.07 Irbilkili A 3/4 35SP3006 1.12 350 700 0.1 1 1 35S63010 125 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3- Union with Brass Seat A Size A Packing Weight Part Number • ,_- 9 in In Inner Master lb 14 , » '� aso 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3014 2.62 15 30 1.7 1-1/2 35U 3014 262 10 20 1.7 eiliallitarm" bassi 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com Ductile Iron Fittings- Class 300 UL/FM c13us APPROVED A A Fig. 35X 3- Cross LISTED t---%I(--� Weight __ Size Part Number A Packing g \',d!�� in in Inner Master lb K•, I �•4�1 IA 1 35X 3010 1.50 20 40 0.9 h 1I 1-1/4 35X 3012 1.75 12 24 1.4 I 11 1-1/2 35X 3014 1.94 8 16 1-8 I / TA 2 35X 3020 2.25 6 12 2.8 B B Fig. 35RX3-Reducing Cross :■ Size Part Number A B Packing Weight „.. ..� A in n in Inner Master b __ I __1__ 1-1/4 x 1 1-1/2 x 1 358X3012010 1.67 1.58 15 30 1.2 �t - 35RX3014010 1.80 1.65 12 24 1.4 L. I . yA 2 x 1 35RX3020010 2,02 1.73 8 16 2.0 Fig. 35C 3- Cap lib .............. ., Size A Packing Weight (air Part Number in in Inner Master lb A 1/2 35C 3004 0.87 300 6CD 0.1 3/4 35C 3006 0.97 200 400 0.1 i� 1 35C 3010 1.16 110 220 Cl. .� 1-1(4 35C 3012 1.28 70 140 0.4 s' �' 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 + ; 2-1/2 35C 3024 1.70 18 36 1.6 n Fig. 35BC3-Beam Clamp Size A Packing Weight [ �� Part Number A n in Inner Master lb _ 77��+' ■ 3/8 358C3003 0.75 100 200 0.3 . _ ■Od 1/2. 35BC3004 0.75 80 160 0.5 aea Uie * • • www.smithcooper.com 4 SMITH COOPER[\TERNATIONALTOLL FREE 1-800-766-0076FAX(323)890-4456 • 11 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T `UsTE®US ® (VdS) 9P`B' SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating'h,3,and 1"/15,20 and 25mm outlets for directly connecting sprinklers,drop nipples, sprigs,gauges,drains and other outlet products. Available for 11/ through 76.1 mm/32 to 76.1mm piping systems,Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. # ' The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall,Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Gasket: • Grade"E"EPDM-Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E"Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel(North America, Latin America,Asia Pacific) • Red enamel(Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. rlutaLJIiC.� IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 DIMENSIONS Nominal Size Hole Approx. incheslmm Diameter Dimensions-inches/millimeters Weight Each Z .,. ywv.a ..vJ .. .,. . .. s 1�/� h 13/16 130 °3 110 387 2.56 1 0 ��� 32 X 15 j 302 330 n�5 279 983 650 045 T 3/a 13/16 L28 1.83 1.10 3.87 2.56 1.1 I :� i. t (���."��J 20 3Q2 32.5 46.5 2Z9 98.3 65.0 0.50 • r.,�,�r�W l�Y __. i 13/16 1.52 2.18 1.10 3.87 2.56 1.2 �/ _ 25 30.2 38.6 554 27.9 98.3 65.0 0.54 11/2 S 13/16 1.42 1.95 1.22 4.08 2.56 1.2 40 X 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3 1 3/16 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1.... 13/16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31 0 103.6 65.0 0.59 2 Vz 13/16 1.66 2.19 1.46 4.60 2.56 1.3 50 X 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 Yr 13/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 13/16 1.88 2.54 146 4.60 2.56 15 ,._ 25 _j 30.2 47.8 64.5 37.1 116.8 65.0 068 2 1/2 Yr 1 3/16 1.91 2.44 1.71 5.40 2.56 1.6 65 X 15 30.2 48.5 62.0 43.4 137.2 65.0 0,73 14 1 3/16 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 13/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm X 1/2 '.,. 13/16 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 Ya 13/16 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 434 139.7 65.0 0.73 1 13/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65,0 0.80 1 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. 'Center of run to engaged pipe end for NPT threads(dimensions are approximate). • www.victaulic.com lctc1 V lICi VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL Run Size n Outlet Size 213,Section 16)(C=1201*,FT a',d .......is y J: 1 r/ 1 8.5 32 X 25 2.6 1'/ 1 8.5 40 X 25 2 6 2 1 8.5 50 X 25 2.6 2 1/2 X 1 8.5 65 25 2.6 5 76.1 MtnX 25 2.6 *Hazen-Williams coefficient of friction is 120 www.victaulic.com rr+taVIue VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 0 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. • WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.52 3355 REVG UPDATED 12/2009 •Ct9UlIC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 02009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig.B3170NF) ®TOLCG Fig. 200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) CO us Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig.200 - 1/2" (15mm)thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled J swivel nut design permits hanger adjustment after installation. Features: • • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe �' types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily a - a installed around pipe. A r '. For hanger with non-captured nut order Fig. 200S. ;, - a • (21/2" (65mm)thru 8" )200mm1) Spring tension on nut holds it securely in ' L `'-- hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" 115mm)thru 8" (200mm)) _ Fig zo-/2 zao 374 in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved(FM) (3/4" (20mm)thru 8" (2o0mm)). Fig.zgatto2oo2 Fig.zoezt/stozaoe Conforms to Federal Specifications WW-H-171E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F 1343°C) Finish: Pre-Galvanized. Stainless Steel c ' materials will be supplied with (2) hex nuts '` in place of a knurl nut. 8'i Order By: Figure number and pipe size Designed to meet or exceed requirements of a FM DS 2-0. i v a_ Fig.200 a Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 - Part No. in. (mm) in. Imml in. (mm) lbs. (kg) 200-1/2 1/2" 115) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.01 200-3/4 3/4" 120) 3/3"-16 31/8" (79.4) 21/2' (63.5) 11 (5.01 200-1 1" 125) 3/8"-16 33/8" (85.71 25/8" (66.7) 12 (5.5) 200-11/4 11/4" (32) 3/a'-16 33/4' (94.0) 27/8" (73.0) 13 (5.9) 200-11/z 11/z" (40) 3/8"-16 37/a" (98.4) 27/8" (73.0) 14 (6.4) 200-2 2" (50) 3/8%16 41/2" (114.3) 3" (76.3) 15 (6.9) 4 200-21/z 21/z' (65) 3/9"-16 55/8" (142.5) 41/a' (104.7) 27 (12.31 200-3 3" (75) 3/8"-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" 1187.31 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/B"-16 73/3" (187.3) 5" (127.0) 35 (16.0) 200-5 5" 1125) 1/2°-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" 1150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2°-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B Line Fire Protection Solutions - 21 by E"T•Ili Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) B3205L - Threaded Rod (right & left hand threads) / TL " Size Range: 3/8"-16 thru 3"-4 rod Specify Length 0 ) Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. TL ll\1 Rod is threaded on both ends with right hand threads of the length shown.Also \110, available with left and right hand threads-specify Fig. B3205L when ordering. to) A Thread size Maximum Temperature: 750°F(399°C) Finish: Plain.Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Desig■Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 83205-7/e x'L' 7/8"-9 31/2' (88.9) 4480 (19.93) 3508 (15.60) 63205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 03205-11/8 x'L' 11/8"-7 41/2' (114.3) 7450 (33.14) 5830 (25.93) B3205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'L' 11/2%6 6" (152.4) 13800 (61.38) 10807 (48.07) 83205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 83205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2 x'12 21/2%4 10" (254.0) 39800 (177.03) 31169 (138.64) 23205-23/4 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) 133205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 - All Threaded Rod Cut To Length �� Tom, , goi Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m) lengths or cut to length ,��.� Material: Steel '� � �� v m Maximum Temperature: 750°F(399°C) ,. a o Finish: Plain. Contact B-Line for alternative finishes and materials. °2 o Order By: Part number, rod diameter and finish �a Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Fi. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/8"x 120 99-3/8"x length 16 730 (3.24) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATR 5/e"x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) ATR 7/s"x 120 99-7/a"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. • Pipe Hangers&Supports 236 Revised4/28/2014 B Li Line. by E_C•N