Permit 101 CITY OF TIGARD MASTER PERMIT
.' COMMUNITY DEVELOPMENT Permit#: MST2021-00290
T I i A I' 1) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/29/2021
Parcel: 2S103CC04800
Jurisdiction: Tigard
Site address: 13931 SW AERIE DR
Subdivision: EAGLE POINTE Lot: 54
Project: Williams
Project Description: 7.03 kW rooftop solar
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $38,729.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Fum>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0
Ea add,500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N
Other: Y Other Description: Roof Top Solar PV System 7.03 kW Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
OTR SF VB R-3 0
Owner: Contractor:
WILLIAMS,ROGER M&NAOMI F GREEN RIDGE SOLAR Required Items and Reports(Conditions)
13931 SW AERIE DR 19450 SW MOHAVE CT
TIGARD,OR 97223 TUALATIN,OR 97062
PHONE: PHONE: 503-395-1943
FAX:
Total Fees: $470.47
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION' Oregon law re uires you to f low the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
cc9-nnl-flnin thrniinh rl 9_nni On V m,nhfain a of flue nr'liner}mmeline In flu WC by Wallin Fn'2 979 1OR7 nr'I Ann 119 9744
c n.,
Issued By: i Permittee Signature: G%/LL ea0>cl-i
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the iob site at the time of each inspection.
RECEIVED
City of Tigard JUL 1 s zoo;
'' Building Division CITY OF TIGARD
13125 SW Hall Blvd,Tigard, OR 97223 BUILDING DIVISION
Phone: 503.718.2439 Fax: 503.598.1960
TIGARD Inspection Line: 503.639.4175
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
Photo Voltaic Solar Panel System
Property Information
Installation Address: 13931 SW Aerie Dr.
City: Tigard Zip: 97223
Owner's Name: Roger Michael Williams Date: 7/16/2021
Contractor's Name: Green Ridge Solar CCB #: 210450
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? E No OSSC or ORSC for
design requirements.
Is the wind exposure 0 Yes If"Yes", qualifies for
Wind Exposure "C"or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes Q Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 p or less?
If"Yes", qualifies for
structures other than
Yes the prescriptive path.
above ❑
No
I
I:/Building/Forms/PhotoV oltaic-Checklist02-01-11.docx
Is the construction
material wood and does 0 Yes
Type of If"Yes", qualifies for
the construction qualify El No the prescriptive path.
Construction as"conventional light
frame"construction?
is the spacing 24 inches
or less?
Pre-engineered trusses. ❑ Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. O If"Yes", qualifies for
Yes the prescriptive path.
❑ No
Is the combined weight ❑x Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance ❑x Yes
with Section 305.4(3) of If"Yes", qualifies for
❑ No the prescriptive path.
the 2010 Oregon Solar
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max.two layers the prescriptive path.
E of composition
shingle.
Is the roof mounted ❑x Yes
Connections of solar assembly
the solar assemblyconnected to roof If"Yes",pqrescriptive
p for
❑ No the prescriptive path.
to the roof framing or blocking
directly?
2
1:/Building/Forms/PhotoV oltaic-Checklist02-01-11.docx
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less? ❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum #10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. W'thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12"o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof ❑x Yes the prescriptive path.
surface. ❑ No
3
UBuilding/Fomis/PhotoV oltaic-ChecklistO2-01-11.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size,type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: Silfab
Model Number: SIL-370BK
Listing Agency: UL
4