Report Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
, am the general contractor or the owner-builder
at the following address:
Site Address:
k Lk Cz$ Co(a-sT 1137cLr-L_
City
k
Permit#:
NAS-Va.0V-E —670(t-ACt
Subdivision/Lot#:
ok and/or
Map Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement,of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of thy framing members.
Signature: Date: -) I H /
cçj or Owner-Builder
B.BuildhasiFerm\RES-MoisturcSaisitiveWood.doc 09254)8
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
, am the general contractor or the owner-builder
at the following address:
Site Address:
ILV-6-1cD G. CJC3 A-ST 177,6L9—
City:
Permit#: le:)30—op it-tq
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Banier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
The ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
RiOints lapped 12"at seams and
El- tending up the founriAtion walls 12".
3 !,„-
Signatur . Date: -7 / 7-I
ar Owner-Builder
D.BuildingWorm\FLES-MoutureBwrier.daa 09/13/2016
Oregon Residential. Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: cDgo_col Lict Jurisdiction:
ktyrs.
Site Address:
t c> aset-1.-C) (....‘"( eST 173-0-D—
Subdivision/Lot#:
9 I:,
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy•of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature: Date:
-. .., tractor/Authonzed Agent
Print Name:
1 ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or!Mem-fluorescent,or a minimum efficacy of 40 lumens per
input watt
1:1BuildingWorenARES-HighEfficiencyLighting.doc 07/01/08
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tyler@moffetco.com
Blower Door Test Affidavit
Permit#: Builder: Taylor Morrison
Site Address: Roshak Lot 96: 14370 SW Gold Coast Ter,Tigard, OR 97224
Conditioned Floor Area (sq.ft.): 1417
Source: Calculated from plans Calculated Building Volume (cubic feet): 12616
TEST RESULTS: 1044 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60)_Volume): 4.97
Ring: Open 0 B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician:Tyler Moffet
Technician Signature: 7 1�7`/�" Date: 7/8/2021
�.
4RV Wel cc. a& .r& Os—A11-4
Certificate of Compliance
This document certifies that the fiberglass insulation has been installed in conformance
Y with the manufacturer's recommendations and requirements to provide thermal resistance value(s)of:
,
R-value Thickness Coverage Area
Ceilings: R-49 X New Construction
Vaults/Slopes:
Walls: () Upgrade
Blown in R-23
Rim Joist:
Floors:
Over Garage R-38
Crawl Vapor Barrier installed Y N Sprinkler Tenting 4 mil Poly x Y N
Loose-Fill Insulation
R-49 using bags of insulation to cover 624 square feet of area at a thickness of 16.75 inches.
Owens Corning'PROPINK"L77 Loosefill Insulation
Owens Corning will accept no responsibility when the product is not installed in accordance with the product label.Stated R-value is provided by
installing the required numberofbags at a thickness not less than the labeled minimum thickness.Installation of the required number of bags may yield
more than the specified minimum thickness.Failure by the installer to provide both the required bags and at least the minimum thickness will result
` in lower insulation R-value.
R-VALUE BAGS PER MAXIMUM NET MINIMUM WEIGHT MINUMUM
1000 SQ.FT. COVERAGE PER SQ.FT. THICKNESS
To obtain a No.of bags per 1000 sq. Contents of this bag Weight per sq.ft.of Installed insulation t
thermal resistance ft.of net area: should not cover installed instal.should should not be less 9
(R)of: more than:(sq. ft.) not be less than:(lbs.) than:(in.)
60 28.0 35.8 0.895 20.00
49 22.2 45.0 0.71 I 16.75
44 19.7 50.7 0.63I I5.00
38 16.7 59.9 0.534 13.25
30 13.0 77.0 0.416 10.50
a
26 11.2 89.6 0.357 9.25
1 22 9.4 I06.3 0.301 8.0i)
19 2.0 125.0 0.256 7.00 'I
13 5-I 1.84.6 0.173 4.75
E
Property Address: 14370 SW Gold Coast Terrace Lot 96, Tigard, OR e
4
5/11/21 Carolina Jarquin
{ Date of Installation Westside Drywall Inc.authorization
7/02/21 C ee •' -trust.
Today's Date Buildi/Co.tractor's Signature 3
t Taylor Morrison ':
Company/Customer Name 1
P.O.BOX 99*HUBBARD,OR 97032*(503)620-7036*FAX(503)624-0599*CCB#71044