Report Oregon Residential Specialty Code R408.1 MOISTURE BARRIER ACKNOWLEDGEMENT FORM I, , am the general contractor or the owner-builder at the following address: Site Address: 1L-ISct'-‘ St—) City: Permit#: 1.`--)\:5 -Oc) 6 Subdivision/Lot#: Ct3 and/or Map and Tax Lot Oh To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1 Ventilation.I am notifying the building official that I have installed the Moisture Barrier as per Requirement in ORSC Section 408.1 and have taken the following steps to meet this code requirement: r 'fhe ground surface of the under-floor space is covered with 6-mil blark polyethylene sheeting with LIintS lapped 12"at seams and rq- xtending up the foundation walls 12". sigoatur Date: -1( t 1419-1 or Owner-Builder ts 1:93trildineFonnIRES-Moisturelkanc.r.doc 09/13/2016 Oregon Residential. Specialty Code N1107.2 HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS Permit No.: As-c- 4.0 RsD _00 1.4 G. Jurisdiction: ( Site Address: I Lii-Vst LA S Cm%CSC- C_O Or-ST Subdivision/Lot#: CA and/or Map and Tax Lot#: By my signature below, I certify that a minimum of fifty(50)percent of the permanently installed lighting fixtures in the above mentioned building have been installed with compact or linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt. (Oregon Residential Specialty Code N1107.2)I Signature: Date: -7/I 4/2-1 'Cohtractor/Authonied Agent Print Name: (- A',.2k. ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this requirement. The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per input watt IABuildingTorms1RES-HighEffieiencyLightinvioc 07/01/08 Moffet Energy Modeling CCB#223372 Phone: 916-342-0742 tyler@moffetco.com Blower Door Test Affidavit Permit#: Builder: Taylor Morrison Site Address: Roshak Lot 93: 14394 SW Gold Coast Ter,Tigard, OR 97224 Conditioned Floor Area (sq.ft.): 1168 Source: Calculated from plans Calculated Building Volume(cubic feet): 10678 TEST RESULTS: 793 CFM @ 50 Pa ACH @ 50 Pa =((CFM x 60)_Volume): 4.46 Ring: Open OA B Minneapolis Blower Door and DG 700 Manometer I certify that these building leakage rates are accurate and determined using standard BPI testing protocol. Company Name: Moffet Energy Modeling Technician:Tyler Moffet Technician Signature: ,_y/� !�� Date: 7/8/2021 (1,, 111400110e 44,;,w4l-t ,a.I NS Ut s*T1 Certificate of Compliance This document certifies that the fiberglass insulation has been installed in conformance with the manufacturer's recommendations and requirements to provide thermal resistance value(s)of: R-value Thickness Coverage Area Ceilings: R-49 X New Construction Vaults/Slopes: Walls: 0 Upgrade Blown in R-23 Rim Joist: Floors: Over Garage R-38 _ Crawl Vapor Barrier installed Y N Sprinkler Tenting 4 mil Poly x Y _N Loose-Fill Insulation R-49 using_bags of insulation to cover 676 square feet of area at a thickness of 16.75 inches. Owens Corning-PROPINK'L77 Loosefill Insulation Owens Corning will accept no responsibility when the product is not installed in accordance with the product label.Stated R-value is provided by installing the required number of bags at a thickness not less than the labeled minimum thickness.Installation of the required n umber ofbags may yield more than the specified minimum thickness.Failure by the installer to provide both the required bags and at least the minimum thickness will result in lower insulation R-value. R-VALUE BAGS PER MAXIMUM NET MINIMUM WEIGHT MINUMUM 1000 SQ.FT. COVERAGE PER SQ.FT. THICKNESS To obtain a No.of bags per 1000 sq. Contents of this bag Weight per sq. ft.of Installed insulation ' thermal resistance ft.of net area: should not cover installed insul.should should not be less (R)of: more than:(sq. It.) not be less than:(lbs.) than:Iin.) 60 28.0 35.8 0.895 20.00 49 22.2 45.0 0.711 16.75 44 19.7 50.7 0.631 15.00 38 16.7 59.9 0.534 13.25 ( 30 13.0 77.0 0.416 10.50 1 26 1 1.2 89.6 0.357 9.25 22 9.4 106.3 0.301 8.00 19 8.0 125.0 0.256 7.00 13 5.4 184.6 0.173 4.75 Property Address: 14394 SW Gold Coast Terrace Lot 93, Tigard,OR 5/11/21 Carolina Jarquin Date of Installation Westside Drywall Inc.authorization �7 7/02/21 r✓a2te1isia, I, -c aiv Today's Date Build./Cs tractor's Signature 1 Taylor Morrison Company/Customer Name P.O.BOX 99*HUBBARD,OR 97032*(503)620-7036*FAX(503)624-0599*CCB#71044