Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
roiCITY OF TIGARD MASTER PERMIT a COMMUNITY DEVELOPMENT Permit#: MST2021-00212 I G A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 06/09/2021 T Parcel: 1 S 125CA11800 Jurisdiction: Tigard Site address: 9245 SW 74TH AVE Subdivision: 2007-083 PARTITION PLAT Lot: 1 Project: Fasano Project Description: Rooftop Solar PV BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage. 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $7,785.99 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains. 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker. 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Tema Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add,500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: Y Other Description: Roof Top Solar PV System 8.625 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: CORNYN,JOYCE FASANO TRUST BRS FIELD OPS LLC Required Items and Reports(Conditions) BY CORNYN,JOYCE&CORNYN 1403 NORTH RESEARCH WAY TRS OREM,UT 84097 9245 SW 74TH AVE PORTLAND,OR 97223 PHONE: PHONE: 855-205-2530 FAX: Total Fees: $359.69 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling Uy 503.232.1y91877�oor�1.800.332.2344. Issued By: ;fo Va wr4pplt'ctvDe,We�e Permittee Signature: Oatiev1'Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application 5_5 Residential ri ECEIVED FOR OFFICE USE ONLY Cityof Tigard MAY %ttg7 Rece1V� Permit No.: ��/(47 7 ,R]j1 7 g 5 GULB Date/By:O� �t!/�1GJ tvl8 O2(-6O21L f1 " 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Phone: 503.718.2439 Fax: 503.598.196(} Date/By: CQ I Z) t Other Permit: Inspection Line: 503.639.4175 13ITV OF TIGARD Date Read/B Juris, 1 f �.�;!+ Pe Y Y ® See Page 2 for Internet: www.tigard-or.gov 'BUILDING DIVISION N red/Method: 7 3 �� Supplemental Information TYPE OF WORK ',Ws , D DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑ Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. El1-and 2-family dwelling ❑Commercial/industrial Valuation: $ 77$5,99 ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder El Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: 11 Job site address: 9245 SW 74th Ave,Tigard, Oregon,97223 New dwelling area: square feet City/State/ZIP: Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Joyce Fasano Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Rooftop Solar PV U - S FVv Valuation: $ Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name: Joyce Fasano Type of construction: Address: 9245 SW 74th Ave,Tigard,Oregon,97223 Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( ) New: 0 APPLICANT IE CONTACT PERSON BUILDING PERMIT FEES* Business name: BRS Field Ops, LLC (Please refer to fee schedule) Structural plan review fee(or deposit): Contact name: Jeff Lee Address: 1403 N Research Way FLS plan review fee(if applicable): City/State/ZIP: Orem, UT 84097 Total fees due upon application: Amount received: Phone:( 385)482-0045 Fax: :( ) E-mail: permitting.deparment@blueravensolar.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* CONTRACTOR Commercial and residential prescriptive installation of roof-top mounted PhotoVoltaic Solar Panel System. Business name: BRS Field Ops, LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 1403 N Research Way Solar Installation Specialty Code checklist. City/State/ZIP: Orem, UT 84097 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( 385)182-0045 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.: 227185 Total fee due upon application: $201.60 Authorized signature: // This permit application expires if a permit is not obtained � within 180 days after it has been accepted as complete. • Print name: Jeffrey ee Date: 05/20/2021 Fee methodology set by Tri-County Building Industry Service Board. I:\BuildinglPermits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Applicatio FOR OFFICE USE ONLY City of Tigard tECEIVED Received Date/B : Permit#: -O a 13125 SW Hall Blvd.,Tigard,OR 97223 � �� �Z g Plan Review Phone: 503.718.2439 Fax: 503.598.1960�AY 5 2021 D81e/B : Related Permit it: Inspection Line: 503.639.4175 Ready Date/By: H See Page 2 for 1'GARR Internet: www.tigard-or.gov CITY OF TIGARD Notified/Method: Supplemental Information TYPE OF vaililI[I.DING DIVISION PLAN REVIEW ❑New construction 0 Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): ❑Service or feeder 400 amps or more 0 Building over three stories. ❑Demolition 0 Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. Q 1-and 2-family dwelling ❑Commercial/industrial ID Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. ❑Multi-family 0 Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived ❑Addition of new motor load of system. Job#: Job site address: 9245 SW 74th Ave,Tigard, Oregon, 97223 IOOHP or more. ❑"A","R "1-z "1-3", City/State/ZIP: ❑Six or more residential units. occupancy. 0 Health-care facilities. ❑Recreational vehicle parks. Suite/bldg./apt.#: Project name: Joyce Fasano 0 Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Description I Qty. I Each I Total I * New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add']500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential Rooftop Solar PV (with above sq.ft.) 75.00 2 Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy ❑ See Page 2 m PROPERTY OWNER ❑ TENANT Services or feeders installation,alteration,and/or relocation Name: Joyce Fasano 200 amps or less 100.70 2 Address: 9245 SW 74th Ave,Tigard,Oregon, 97223 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: 601 amps to 1,000 amps 301.04 2 Phone: ( ) Fax: ( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: _ __ Date: 401 amps to 599 amps 168.54 2 El APPLICANT 0 CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name: BRS Field Ops, LLC above service or feeder fee, 7.42 2 each branch circuit Contact name: Jeff Lee B.Fee for branch circuits without _ Address: 1403 N Research Way service or feeder fee,first branch circuit 56.18 2 City/State/ZIP: Orem, UT 84097 Each add'I branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( 385)182-0045 Fax: : ( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email: permitting.department©blueravensolar.com Reconnect only 67s4 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name: BRS Field Ops, LLC Sign or outline lighting 67.84 2 Address: 1403 N Research Wa Signal circuit(s)or limited-energy 0 See Page 2 2 y panel,alteration,or extension. City/State/ZIP: Orem, UT 84097 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:( 385 482-0045 Fax: ( ) Investigation(1 hr min) 90.00/hr Email: permitting.department= blueravensolar.com Industrial plan[(1 hr min) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lic.: 227185 Electrical L'c.' C1493 Suprv.Lic.: 6394S specifically listed(V2 hr min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: Subtotal: Print name: Shan Whittaker Date: 05/20/2021 ❑Plan Review Required(25%of permit fee): -.. - State surcharge(12%of permit fee): Authorized signature: i 7�/� TOTAL PERMIT FEE: j % Date: 05/20/2021 This permit application expires if a permit is not obtained within 180 Print name: Jeffrey L days after it has been accepted as complete. * Number of inspections allowed per permit. I:\Building\Permits5ELC_PermitApp_L'IR_ERC.duc Rev 06/17/2015 440.4615T(11/05/Coht/WEB . * Electrical Permit Application-City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Fee for all residential systems combined: $75.00 Description Qty. Each Total y Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed('A hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system: $75.00 Subtotal r permnter t.o Page 1): (SEE OAR 918-309-0000) Number of inspections allowed pe perm Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:111uildingwermils\iLC_PermilApp_lil.R IiRF..doc Rev 06/17/2015 City of Tigard RECEIVE "' Building Division Mk 5 202i 13125 SW Hall Blvd,Tigard, OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 CITY OF TIGARD T I G A R D Inspection Line: 503.639.4175 3UILDING DIVISION www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 9245 SW 74th Ave, Tigard, Oregon, 97223 City: Zip: Owner's Name: Joyce Fasano Date: 05/20/2021 Contractor's Name: BRS Field Ops, LLC CCB #: 227185 Design Parameters of the Property/Structure If"Yes", does not Is the install i n Flood Hazard at o U Yes qualify for the Located in a flood prescriptive path, follow Area plain/flood way? IN No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure 0 Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes 0 Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other thanIf"Yes", qualifies for El Yes the prescriptive path. above ❑ No 1 1 Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Is the construction Yes material wood and does Type of If"Yes", qualifies for the construction qualify Construction ❑ No the prescriptive path. as "conventional light frame" construction? Is the spacing 24 inches or less? If"Yes", qualifies for Pre-engineered trusses. IN Yes the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. p If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight p Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes If"Yes", qualifies for with Section 305.4(3) of Oregon Solar ❑ No the prescriptive path. the 2010 Code? ❑ Metal Single layer g Y If roofing material is ❑ of wood RoofingCheck the type of one of the three types YP YP material roofing material shingle/shake checked, qualifies for the path. Max. two layers prescriptive p of composition shingle. Is the roof mounted Yes Connections of solar assembly the solar assembly connected to roof No If"Yes",prescriptiveqpaies for framingor blockin ❑ the path. to the roof g directly? 2 I:Building/Forms/Photo V oltaic-Checklist02-01-11.docx Is the gauge 26 or less? E Yes If"Yes", qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. %"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for MI solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 I:Building/Forms/Photo V oltaic-Checklist02-01-11.docx . 1 Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: JinKO Solar Eagle Model Number: JKM375M-6RL3-B Listing Agency: CSA 4 1:/13 uilding/Forms/Photo V o]talc-Check]i s t02-O 1-11.docx