Permit CITY OF TIGARD MASTER PERMIT
1111 la- n COMMUNITY DEVELOPMENT Permit#: MST2021-00169
.TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/24/2021
Parcel: 1S135CD02800
Jurisdiction: Tigard
Site address: 9550 SW LEWIS LN
Subdivision: BOETCHERS ADDITION TO GREEN BURG I Lot: 6
Project: Nicholson
Project Description: Rooftop Solar PV
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $10,600.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0
Drains: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Other Fixtures: 0
Drywell-Trench Drain: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea addl 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Horne/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: NI Vaccuum System: N Garage Opener: N All
Other: Y Other Description: Roof Top Solar PV System 10 KVA Ecompasing: N
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
ALT SF VB R-3 0
Owner: Contractor:
NICHOLSON,JADE M&ERIK W AAND R SOLAR CORP Required Items and Reports(Conditions)
9550 SW LEWIS LN 1887 SW MILPORT RD
TIGARD,OR 97223 MILWAUKIE,OR 97222
PHONE: PHONE: 503-939-7663
FAX:
Total Fees: $354.69
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will
be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180
days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952-001-0010 through SOAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344.
H
Issued By: "'7^'Y Van/De,WPge Permittee Signature: 0YVf4ppUcca o-Vt
Call 503.639A175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the Job site at the time of each Inspection.
Building Permit Applicatio E"EIVED
Residential AP 2 0 202`1 FOR OFFICE USE ONLY
g CITY OF TIGARD Date 3y: a' 2/ '� MSr2oL-ew61
Cityof Tigard , Per"N .
DatelBy:
� 13125 SW Hal]Blvd.,Tigard,OR 97.41'1 Plan Review{
Phone: 503.718.2439 Fax: 503.59RebLDING DIVISION l y( 2 Other Permit:
TIGARD Inspection Line: 503.639.4175 D. -Ready/By: ,4uy- Pi See Page 2 for
Internet: www.tigard-or.gov - ified/Method: f 1� Supplemental Information
�i
TYPE OF WORK e i¢ r e� NI)2-FAMILY D-,•' Pf*"v;
❑New construction ❑Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
✓❑AdditiovaIteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the
. IY 7flill N'LeIADtO'I.Y II. Mt -�: _
' work indicated on this application.
t'
El1-and 2-family dwelling ❑Commercial/industrial Valuation: $ 10,600.00
f\ ❑Accessory building ❑Multi-family Number of bedrooms:
Number of bathrooms:
❑Master builder ❑Other:
- `•'`'. : JOB SITE INFORMATION ND LOCATION Total number of floors:
Job site address: 9550 SW Lewis Ln New dwelling area: square feet
City/State/ZIP: Tigard,OR 97223 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name: NICHOLSON Covered porch area: square feet
Cross street/directions to job site: SW of SW 95th Ave and SW Lewis Ln. Deck area: square feet
Other structure area: PV array 692 square feet 21%roof coveravy
EQUIRE ,+ O; l, 15,a, USE CHECKLIST
Subdivision: Lot no.: Permit fees*are based on the value of the work performed.
Fax map/parcel no.: 1S135CD02800 Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Valuation: $
Rooftop installation of a 10 KVA photovoltaic system on a STD.
Existing building area: square feet
New building area: square feet
qi
t •T
I ' Y OWNER 0 ❑ TENANT Number of stories:
Name: Erik Nicholson Type of construction:
Address: 9550 SW Lewis Ln Occupancy groups:
City/State/ZIP: Tigard,OR 97223 Existing:
Phone:( 415 )309-8371 Fax:( ) New:
Q APPLICANT Q CONTACT PERSON BUILDING PERMIT FEES*
Business name: A&R SOLAR SPC (Please refer to fee schedule)
Structural plan review fee(or deposit):
Contact name: Lara Worcester
FLS plan review fee(if applicable):
Address: 6800 NE 59th P1
Total fees due upon application:
City/State/ZIP: Portland,OR 97218
Amount received:
Phone:(503 )420-8680 ext 4 Fax::( )
PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
E-mail: permits@a-rsolar.com --
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System.
Business name: A&R SOLAR SPC Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address: 6800 NE 59th PI Solar Installation Specialty Code checklist.
City/State/ZIP: Portland,OR 97218 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:( 503 )420-8680 Fax:( )
State surcharge(12%of pemit fee): $21.60
CCB lie.: 207641 Total fee due upon application: $201.60
Authorized signature: //', /i This permit application expires if a permit is not obtained
Leidta, L!/B2!'.QQ.t�Pi2. within 180 days after it has been accepted as complete.
Print name: Lara Worcester Date: 4/20/2020 *Fee methodology set by Tri-County Building Industry
Service Board.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(I 1/021COMJWEB)
•
Building Permit Application Checklist
One- and Two-Family Dwelling FOR OFFICE USE ONLY
City of Tigard aecwilred Permit No.:
Date/By• 13125 SW Hall Blvd.,Tigard,OR 97223 Associated
Phone: 503.718.2439 Fax: 503.598.1960 Associated permits:
24-Hour Inspection Line: 503.639.4175 ❑ Electrical ❑ Plumbing ❑ Mechanical
it;AKII
Internet: www.tigard-or.gov ❑ Other:
THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW S cs No N/A
I Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ 0
2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. n 0 0
3 Verification of approved plat/lot. ❑ ❑ M
4 Fire district approval required. Name of district: ❑ ❑ ❑✓
5 Septic system permit or authorization for remodel. Existing system capacity 0 0 n
6 Sewer permit. ❑ ❑ n
7 Water district approval. ❑ ❑ n
8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ 0 n
9 Erosion control ❑plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- 0 0 I]
basin protection,etc.
10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state ❑✓ ❑ ❑
building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size
sheet attached to the plans with cross references between plan location and details. Plan review cannot he completed if
copyright violations exist.
11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if O ❑ ❑
there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements
and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction
indicator,lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and
surface drainage.
12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ 0 ❑.✓
and location.
13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑ ❑ ❑✓
furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc.
14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑✓ ❑ ❑
floor,wall construction,roof construction. More than one cross section may be required to clearly portray
construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings
and foundation,stairs,fireplace construction,thermal insulation,etc.
15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. OD 0 ❑
Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope.
Full-size sheet addendums showing foundation elevations with cross references are acceptable.
16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- 0 0 ✓❑
prescriptive path analysis provide specifications and calculations to engineering standards.
17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing ❑✓ 0 0
locations. Show attic ventilation.
18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ U
systems,see item 22,"Engineer's calculations."
19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑✓
over 10 feet long and/or any beam/joist carrying a non-uniform load.
20 Manufactured floor/roof truss design details. El ❑ ❑
21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required �✓ ❑ ❑
for four or more appliances.
22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or 0 0 LI
architect licensed in Ore•on and shall be shown to be a.•licable to the•ro'ect under review.
JURISDICTIONAL SPECIFICS
23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". 1151 0 0
24 Two(2)sets each are required for Items 16, 19,20 and 22 above. I7 ❑ ❑
25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. n ❑ ❑
26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. ❑ ❑ 7
27 "Drawn to scale"indicates standard architect or engineer scale. n ❑
28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ ❑ ❑✓
Street Tree List.
29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑ ❑✓
and protection measures must be drawn to scale and must include the project arborist's signature of approval.
30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑ U
including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings
on a lot of record approved prior to September 9,1995.
I:1 Building\Petmits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(I1/02/COM/WEB)
- .
RECEIVED
Electrical Permit Application -, 0 20� FOR OFFICE USE ONLY
Received
City of Tigard P ,,it a:
OITY OF TIGARD Dan e
114
i • 13125 SW Hall Blvd.,Tigard,OR 9722 Plan Review
Phone: 503.718.2439 Fax: 503.59R 9f1�LDING DIVISION Date/By Related Permit#:
Inspection Line: 503.639.4175 Ready Date/By: orris: EI See Page 2 fur
III,,\l.1) Internet: ww'w.tigard-or.gov Notifiedr'Method: I Supplemental Information
TYPE OF WORK PLAN REVIEW
❑New construction E Addition/alteration/replacement Please check all that apply(subnut 2 sets of plans w/items checked):
❑Service or feeder 400 amps or more ❑Building over three stories.
El Demolition ❑Other:
where the available fault current 0 Marinas and boatyards.
CATEGORY OF CONSTRUCTION .MEexceeds 10,000 amps at 150 volts or ❑Floating buildings.
J 1-and 2-familydwellingCommercial/industrial less to ground,or exceeds 14.000 ❑Commercial-use agricultural
❑ ❑ ❑Accessory building amps for all other installations. buildings. g
❑ Multi-family ❑Master builder ❑Other: ❑Fire pump. 0 Installation of 150 KVA or
& t t'.'m• INFORMATION AND LOCATION =ter' El Emergency system. larger separately derived
❑Addition of new motor load of system.
Job#: Job Site address'
9550 SW Lewis Ln 100HP or more. ❑"A","E","1 2","1 3",
City/State/ZIP: T1gaId,OR 97223 ❑Six or more residential units. occupancy.
❑Health-care facilities. ['Recreational vehicle parks.
Suite/bldg./apt.#: Project name: NICHOLSON ❑Hazardous locations. ❑Supply voltage for more than
❑Service or feeder 600 amps or more. 600 volts nominal,
Cross street/directions to job site: SW of SW 95th Ave and SW Lewis Ln. --- - - ---
Description Qty. Each Total
New residential single-or multi-family dwelling unit.
Subdivision: Lot#: Includes attached garage.
1,000 sq.ft.or less 168.54 4
Tax map/parcel#: 1S135CD02800 Ea.add'1 500 sq.R.or portion 33.92 1
„" DESCRIPTION OF WORD, Limited energy,residential
vlf. (with above sq.ft.) 75.00 2
-
Prescriptive rooftop installation of a 10 KVA photovoltaic system on a SFD. Limited energy,multi-family 75.00 2
residential(with above sq.ft.)
RRenewable Energy Q See Page 2
PROPERTY OWNER ID TENANT Services or feeders installation,alteration,and/or relocation
Name: Erik Nicholson 200 amps or less 100.70 2
Address: 9550 SW Lewis Ln 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP: Tigard,OR 97223 601 amps to 1,000 amps 301.04 2
Phone:(415 )309-8371 I Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email:
relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 I
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2_
Owner signature: Date: 401 amps to 599 amps 168.54 2
l7 , .t 4. a': El CONTACT PERSON Branch circuits-new,alteration,or extension,per panel
A.Fee for branch circuits with
Business name: A&R SOLAR SPC above service or feeder fee, 7.42 2
each branch circuit
Contact name: Lara Worcester B.Fee for branch circuits without
Address: 6800 NE 59th P1 bc cir fu fee,first
bra nnch circuit56.18 2
h t
City/State/ZIP: Portland,OR 97218 Each add'.branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:( 503 )420-8680 ext 4 Fax::( ) Each manufactured or modular
67.84 2
dwelling,service and/or feeder
Email: permits@a-rsolar.com Reconnect only 67.84 2
CONTRACTOR Pump or irrigation circle 67.84 2
Business name: A&R SOLAR SPC Sign or outline lighting 67.84 2
Address: 6800 NE 59th PI Signal circuit(s)or limited-energy ❑ See Page 2 2
panel,alteration,or extension.
City/State/ZIP: Portland,OR 97218 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
Phone:( 503 )420-8680 Fax:( ) Investigation(I hr min) 9000/hr
71//23 Industrial plant(1 hr min) 7R1R/hr
Email: permits@a-rsolar.tom Inspections for which no fee is 90.00,,
CCB Lie.: 207641 Electrical Lie.: C1179 Suprv.Lie.: 5494S specifically listed CA hr hr
n
ELECTRICAL PERMIT FEES
Suprv.Electrician signature,required: 7-2 ‘—,.__ Subtotal: $133.56
Print name: Robert Nieman Date: 4/20/2020 ❑Plan Review Required(25%of permit fee):
State surcharge(12%ofpemtit fee): $16.03
Authorized signature: 6(2 TOTAL PERMIT FEE:
dux This permit application expires if a permit is not obtained within 180
Print name: Lara Worcester Date: 4/20/2020 days after it has been accepted as complete.
* Number of inspections allowed per permit.
1:\Buitdia i'cm,its,ELC PermiiApp_ELA_ERti.duc Rev 06/17/2015 440-4615T(11/t5'COM/WEB
a
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDI,II 137ORKONLY' '' .,.SCHEDULE ;.
". ""'". ""�.'.Y" "."" �"1:..' ,Description Qry. Each Tolal '
Fee for all residential systems combined: $75.00 Renewable electrical energy systems:
Check Type of Work Involved: 5 kva o less 100.70 2
5.01 to 15 kva I 133.56 133.56 2
n Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
n Burglar Alarm 25.01 to 50 kva 301.04 2
❑
Garage Door Opener* 50.01 to 100 kva 552.26 2 g P >100 kva(fee in accordance 552.26 2
with OAR 918-309-0040)
n Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System* Each additional kva over 25 7.42 3
n Vacuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr
charged at an hourly(I hr min)
Inspections for which no fee is 90.00/hr
s Iecificall listed(%hr mint
'COMMERCIAL WORK ONLY: ter
Fee for each commercial system: $75.00 Subtotal(Enter on Page n- 133.56�' • Number ofnspectio s allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
❑ Boiler Controls
n Clock Systems
Data Telecommunication Installation
n Fire Alarm Installation
HVAC
n Instrumentation
n Intercom and Paging Systems
❑ Landscape Irrigation Control*
n Medical
❑ Nurse Calls
n Outdoor Landscape Lighting*
❑ Protective Signaling
Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I:tBuildine\Permits\ELC_PermitApp_ELRERE.doe Rev06/17/2015
RECEIVED
City of Tigard ABM 2 0 202i
Building Division jITY OF TIGARD
13125 SW Hall Blvd,Tigard,OR 97223 ''Q1(11'‘!
Phone: 503.718.2439 Fax: 503.598.1960
T I GARD Inspection Line: 503.639.4175
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 9550 SW Lewis Ln
City: Tigard Zip: 97223
Owner's Name: Erik Nicholson Date: 4/20/2020
Contractor's Name: A&R SOLAR SPC CCB #: 207641
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? El No OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure El Yes If"Yes", qualifies for
"C" or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes ❑✓ Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
If"Yes", qualifies for
structures other than
❑✓ Yes the prescriptive path.
above
❑ No
I
I:/Building/Forms/Photo V olta ic-Chccklist02-01-11.docx
Is the construction
material wood and does ID Yes
Type of the construction qualify If Yes", qualifies for
Construction as "conventional light ❑ No the prescriptive path.
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. IDYes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Is the combined weight ❑✓ Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance ❑✓ Yes
with Section 305.4(3) of If"Yes", qualifies for
Elthe 2010 Oregon Solar No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material rooting material shingle/shake checked,qualifies for
Max. two layers the prescriptive path.
✓® of composition
shingle.
Is the roof mounted ID Yes
Connections of solar assembly
If e
the solar assembly connected to roof "Yes", qualifies for
❑ No the prescriptive
path.
to the roof framing or blocking
directly?
2
CiBuilding/Forms/PhotoVoltaic-Checklist02-01-11.docx
Is the gauge 26 or less? Ti Yes If"Yes",qualifies for
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes",qualifies for
Ti Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes",qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. 't/2" thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12"o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof 0 Yes the prescriptive path.
surface. Ti No
3
1:/Bui lding/Forms/PhotoVoltaic-Checklis102-01-11.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size,type, and
spacing)and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: Hanwha Q.Cells
Model Number: Q.Peak DUO L-G8.2 430
Listing Agency: UL,CE,IEC
4
L/Building/Forms/PhotoVoltaic-Chccklist02-01-11.docx