Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
j +.. Mec2o2c 0i 1171 � 1 o '{ COMcheckSoftware Version COMcheckWeb 5 Q . i, Mechanical Compliance Certificate Project Information RECEIVED Energy Code: 90.1 (2016) Standard OCT 2 2�20 N Project Title: Crescent Grove Location: Tigard, Oregon CITY��Tlr-'A Climate Zone: 4c BUILDING DIVISj D Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: /� 9925 SW Greenburg Road Tom Sorensen 0 Tigard,Oregon 97223 Evergreen Building Systems LLC M 16830 SE Main Street ' Portland,Oregon 97233 503-936-1870 0 tom@evergreensystemspdx.com (fl 0 Mechanical Systems List QuantitySystem Type & Description .‹ 1 HVAC System (Single Zone): Split System Heat Pump Heating Mode: Capacity=26988 kBtu/h, Proposed Efficiency= 3.70 COP, Required Efficiency =3.20 COP Cooling Mode: Capacity = 21004 kBtu/h, , No Economizer, Economizer exception: Net Cool Load <Trans+lnfil Loss Proposed Efficiency= 11.00 EER, Required Efficiency: 9.50 EER + 10.6 IEER Fan System: FAN SYSTEM 1 I Zone 1--Compliance(Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 750 CFM, 1.0 motor nameplate hp, 0.0 fan efficiency grade 1 HVAC System (Single Zone): Split System Heat Pump Heating Mode:Capacity= 26988 kBtu/h, C} Proposed Efficiency=3.70 COP, Required Efficiency = 3.20 COP 'Ti Cooling Mode: Capacity= 21004 kBtu/h, , No Economizer, Economizer exception: Net Cool Load <Trans+lnfil Loss M Proposed Efficiency = 11.00 EER,Required Efficiency: 9.50 EER + 10.6 IEER Fan System: FAN SYSTEM 2 I Zone 2--Compliance (Motor nameplate HP method) : Passes 0 rii Fans: FAN 2 Supply, Constant Volume, 750 CFM, 1.0 motor nameplate hp,0.0 fan efficiency grade 1 HVAC System (Single Zone): 0 Split System Heat Pump Heating Mode:Capacity=44008 kBtu/h, Proposed Efficiency=3.70 COP, Required Efficiency = 3.20 COP Cooling Mode: Capacity =42008 kBtu/h, , No Economizer, Economizer exception: Net Cool Load<Trans+lnfil Loss Proposed Efficiency = 11.00 EER, Required Efficiency: 9.50 EER + 10.6 IEER Fan System: FAN SYSTEM 3 I Zone 3--Compliance (Motor nameplate HP method) : Passes Fans: FAN 3 Supply, Constant Volume, 1441 CFM, 0.5 motor nameplate hp, 0.0 fan efficiency grade 1 HVAC System (Single Zone): Split System Heat Pump Heating Mode: Capacity=44674 kBtu/h, Proposed Efficiency= 3.70 COP, Required Efficiency= 3.20 COP Cooling Mode:Capacity = 47259 kBtu/h, , No Economizer, Economizer exception: Net Cool Load <Trans+lnfil Loss Proposed Efficiency = 11.00 EER,Required Efficiency: 9.50 EER + 10.6 IEER Fan System: FAN SYSTEM 4--Compliance(Motor nameplate HP method) : Passes Project Title: Crescent Grove Report date: 10/20/20 Data filename: Page 1 of 14 \ 1' i • QuantitySystem Type & Description Fans: FAN 4 Supply, Constant Volume, 1441 CFM, 0.5 motor nameplate hp, 0.0 fan efficiency grade Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 90.1 (2016)Standard requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Signature Date Project Title: Crescent Grove Report date: 10/20/20 Data filename: Page 2 of 14 0- , e t f • T! .. t COMcheck Software Version COMcheckWeb Inspection Checklist Energy Code: 90.1 (2016) Standard Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions - 4.2.2, Plans, specifications, and/or ❑Complies 6.4.4.2.1, calculations provide all information Does Not 6.7.2 with which compliance can be DNot Observable [PR2P determined for the mechanical systems and equipment and DNot Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. 6.7.2.4 Detailed instructions for HVAC ❑Complies EPR511 systems commissioning included on ❑Does Not the plans or specifications for projects >=50,000 ft2. ['Not Observable DNot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 12 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Crescent Grove Report date: 10/20/20 Data filename: Page 3 of 14 v f ' e .) 4' Section # Footing I Foundation Inspection Complies? Comments/Assumptions & Req.ID 6.4.3.7 Freeze protection and snow/ice ❑Complies [FO9j3 melting system sensors for future Does Not connection to controls. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) ';,'Medium Impact(Tier 2) 3 Now Impact(Tier 3) Project Title: Crescent Grove Report date: 10/20/20 Data filename: Page 4 of 14 Section Mechanical Rough-In Plans Verified Field Verified # Inspection Value Value Complies? Comments/Assumptions & Req.ID 6.4.1.4, HVAC equipment efficiency Efficiency: Efficiency:_ ❑Complies See the Mechanical Systems list 6.4.1.5 verified. Non-NAECA HVAC ODoes Not for values. [ME1]2 equipment labeled as meeting 90,1, ONot Observable ONot Applicable 6.4.3.4.1 Stair and elevator shaft vents ❑Complies [MEW have motorized dampers that ODoes Not automatically close. . ,,, , ,;'❑Not Observable , ❑Not Applicable 6.4.3.4.2, Outdoor air and exhaust systems DComplies 6.4.3.4.3 have motorized dampers that ODoes Not [ME4]3 automatically shut when not in use and meet maximum leakage ONot Observable rates. Check gravity dampers ,ONot Applicable where allowed. 6.4.3.4-5 Enclosed parking garage ❑Complies [ME39]3 ventilation has automatic AODoes Not contaminant detection and Not Observable capacity to stage or modulate ❑ fans to 50%or less of design ONot Applicable capacity. 6.4.3.4.4 Ventilation fans>0.75 hp have DComplies [ME5]3 automatic controls to shut off fan ODoes Not when not required. ONot Observable ONot Applicable 6.4.3.8 Demand control ventilation DComplies [ME6p provided for spaces >500 ft2 and ❑Does Not >25 people/1000 ft2 occupant k:= ❑Not Observable density and served by systems '" with air side economizer, auto ONot Applicable modulating outside air damper control,or design airflow >3,000 ' cfm. • 6.5.3.2.1 I DX cooling systems>= 75 kBtu/h DComplies See the Mechanical Systems list [ME40F (>= 65 kBtu/h effective 1/2016) DDoes Not for values. „and chilled-water and evaporative cooling fan motor hp ,a ONot Observable >_ '../4 designed to vary supply ONot Applicable :fan airflow as a function of load and comply with operational [ requirements. 6.4.4,1.1 Insulation exposed to weather ❑Complies {ME7]3 protected from damage. ODoes Not Insulation outside of the conditioned space and associated ": ONot Observable with cooling systems is vapor DNot Applicable retardant. 6.4.4.1.2 HVAC ducts and plenums R-_ R-_ ;❑Complies [ME8]2 insulated per Table 6.8.2.Where ❑Does Not ducts or plenums are installed in or under a slab,verification may ONot Observable need to occur during Foundation ONot Applicable Inspection. 6.4.4.1.3 .HVAC piping insulation thickness. _in. _in. DComplies [MEg]2 Where piping is installed in or ODoes Not under a slab,verification may -'need to occur during Foundation ONot Observable Inspection. ONot Applicable 6.4.4.1.4 Thermally ineffective panel ❑Complies [ME4113 surfaces of sensible heating ODoes Not panels have insulation >= R-3.5. ONot Observable ONot Applicable 1 High Impact(Tier 1) Medium Impact(Tier 2) _ 3 jLow Impact(Tier 3) Project Title: Crescent Grove Report date: 10/20/20 Data filename: Page 5 of 14 n ' Section ff Mechanical Rough-In & Req.ip Inspection Plans Verified Field Verified 6.4.4.2.1 Ducts and plenums having A Value Value Complies? Comments/Assumptions [ME10] l z pressure class ratings are Sea "' Class A construction. OComplies °Does Not i 6.4.4,2.2 ;Ductwork operating >3 in. water ONot Observable [ME11]3 ;column requires air leakage ONot Applicable testing. ❑Complies ODoes Not 6.4.4.2.2 Ductwork; operating >3 in. water ONot Observable j [MEil3 "---=-- - ., ONotpliesApplicable ] column requires air leakage testing. '" Complies Does Not 6.4.4.2.2 ;Ductwork operating>3 in, water . "ONot Observable ONot Applicable [ME1193 column requires air leakage testing. OComplfes °Does Not 6.4.4.2.2 'Ductwork operating >3 in. water . ONot Observable ONot Applicable[ME11]3 column requires air leakageF{ j testing. 00omplies ,ODoes Not ,ONot Observable j _ ONot Applicable 6.5.2.3 Dehumidification controls [ME19J3 provided to prevent reheating, recoolingo OComplies ot and cold airstreams or concurrent heating Oboes Not and cooling of the same 'ONot Observable airstream. - ;ONot Applicable 6.5.2.4.1 ;Humidifiers with airstream „[ME68]3 mounted preheatingave � R •preheat auto-shutoff value es t to [ OComplies activate when humidification is • Oboes Not not required. ONot Observable 6.5.2.4.2 ;Humidification system dispersion " 'ONot Applicable [ME69]3 'tube hot surfaces in the ;airstreams of ducts or air- OComplies handling units insulated>= R- ' Oboes Not 0.5. ONot Observable 6.5.2.5 Preheat coils controlled to stop _ ONot Applicable [ME70)3 ;heat output whenever Does Not mechanical cooling, ❑Complies economizer operation, is active. 6.5.2;6 Units that provide ventilation air ONot Observable [ME106]3 to' multiple zones and operate in Not Applicable conjunction with zone heating - ❑Complies and cooling systems are Does Not prevented from using heating or ONot Observable heat recovery to warm supply air ❑Not Applicable ;above 60°F when representative ' 'building loads or outdoor air temperature indicate that most zones demand cooling. 6.5.3.6 Motors for fans>= 1/12 hp and '[ME7212 < 1 hp are electronically- commutated motors or have a .iOCompfies Oboes Not 70%.These motors are also t ,[ ;ONot Observable minimum motor efficiency of speed adjustable for either ONot Applicable balancing or remote control. ©High Impact(Tier 1) Q Project Title: Crescent Grove ®EOw Impact(Tier 3) Data filename: Report date: 10/20/20 Page 6 of 14 t J"s • Ia • Section Mechanical Rough-In Plans Verified Field Verified Req.ID Inspection Value Value Complies? Comments/Assumptions 6.5.3.6 Motors for fans>= 1/12 hp and a .❑Complies [ME72]2 < 1 hp are electronically- I :"❑Does Not commutated motors or have a minimum motor efficiency of ❑Not Observable 70%.These motors are also ❑Not Applicable speed adjustable for either balancing or remote control. 6.5.3.6 Motors for fans>= 1/12 hp and ❑Complies [ME72]2 < 1 hp are electronically- EDoes Not commutated motors or have a �.•„ minimum motor efficiency of ❑Not Observable 70%.These motors are also ❑Not Applicable speed adjustable for either balancing or remote control. 6.5.3.6 Motors for fans>= 1/12 hp and ❑Complies (ME7212 < 1 hp are electronically- ❑Does Not commutated motors or have a Not Observable minimum motor efficiency of ❑ 70%.These motors are also ❑Not Applicable speed adjustable for either balancing or remote control. 6.5.3.4 Parallel-flow fan-powered VAV air ❑Complies [ME108]2 terminals have automatic ❑Does Not controls to a) turn off the ONot Observable terminal fan except when space heating is required or if required ❑Not Applicable for ventilation; b)turn on the terminal fan as the first stage of heating before the heating coil is r :activated;and c) during heating for warmup or setback temperature control, either operate the terminal fan and heating coil without primary air or reverse the terminal damper logic and provide heating from the central air handler through primary air. 6.5.3.4 ;Parallel-flow fan-powered VAV air ❑Complies [ME1O8)2 .'terminals have automatic ❑Does Not controls to a)turn off the ['Not Observable 'terminal fan except when space heating is required or if required _ ❑Not Applicable for ventilation; b)turn on the terminal fan as the first stage of heating before the heating coil is activated;and c) during heating for warmup or setback temperature control,either operate the terminal fan and heating coil without primary air 'or reverse the terminal damper logic and provide heating from the central air handler through primary air. 1 High Impact(Tier 1) IA',Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Crescent Grove Report date: 10/20/20 Data filename: Page 7 of 14 e Section Mechanical Rough-In Plans Verified Field Verified. # Inspection Value Value Complies? Comments/Assumptions Req.ID 6.5.3.4 Parallel-flow fan-powered VAV air r s P y : ❑Complies [ME108)2 terminals have automatic ❑Does Not controls to a)turn off the ` 4- terminal fan except when space ['Not Observable heating is required or if required ❑Not Applicable for ventilation; b)turn on the terminal fan as the first stage of w, _ heating before the heating coil is activated;and c)during heating -" for warmup or setback temperature control,either operate the terminal fan and heating coil without primary air or reverse the terminal damper logic and provide heating from the central air handler through primary air. 6.5.3.4 Parallel-flow fan-powered VAV air DComplies [ME108)2 terminals have automatic ❑Does Not controls to a)turn off the terminal fan except when space GNot Observable heating is required or if required ❑Not Applicable for ventilation; b)turn on the terminal fan as the first stage of heating before the heating coil is activated;and c) during heating for warmup or setback temperature control, either operate the terminal fan and heating coil without primary air or reverse the terminal damper logic and provide heating from .the central air handler through primary air. 6.5.3.7 'Required minimum outdoor air ❑Complies [ME109)2 rate is the larger of minimum ❑Does Not outdoor air rate or minimum exhaust air rate required by ['Not Observable Standard 62.1, Standard 170, or ❑Not Applicable applicable codes or accreditation standards.Outdoor air ventilation systems shall comply with one of the following:a)design minimum system outdoor air provided< 135%of the required minimum i outdoor air rate, b) dampers, ductwork,and controls allow the system to supply<=the required minimum outdoor air rate with a single set-point adjustment.,or ci system includes exhaust air energy recovery complying with Section 6.5.6.1. 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Crescent Grove Report date: 10/20/20 Data filename: Page 8 of 14 Section Mechanical Rough-In Plans Verified Field Verified Inspection Value Value Complies? Comments/Assumptions & Req.iD 6.5.3.7 Required minimum outdoor air t,,`'- ❑Complies [ME109]2 rate is the larger of minimum ❑Does Not outdoor air rate or minimum exhaust air rate required by [Not Observable Standard 62.1,Standard 170,or ❑Not Applicable applicable codes or accreditation standards.Outdoor air ventilation systems shall comply with one of the following: a) design minimum system outdoor air provided < 135%of the required minimum outdoor air rate, b) dampers, ductwork,and controls allow the , system to supply<=the required minimum outdoor air 4` rate with a single set-point adjustment., or c)system includes exhaust air energy recovery complying with Section 6.5.6.1. ' "�* 6.5.3.7 Required minimum outdoor air ❑Complies [ME109]2 rate is the larger of minimum ❑Does Not outdoor air rate or minimum Not Observable exhaust air rate required by ❑ Standard 62.1, Standard 170, or ❑Not Applicable applicable codes or accreditation standards.Outdoor air ventilation systems shall comply with one of ;the following: a)design minimum 'system outdoor air provided < 135%of the required minimum outdoor air rate,b) dampers, I ductwork,and controls allow the system to supply<=the required minimum outdoor air rate with a single set-point adjustment., or c)system includes exhaust air energy recovery complying with Section 6.5.6.1. 6.5.3.7 Required minimum outdoor air ❑Complies (ME109]2 rate is the larger of minimum ODoes Not outdoor air rate or minimum Not Observable exhaust air rate required by ❑ Standard 62.1, Standard 170,or ONot Applicable applicable codes or accreditation 'standards.Outdoor air ventilation systems shall comply with one of the following: a) design minimum system outdoor air provided< 135%of the required minimum outdoor air rate, b)dampers, ductwork, and controls allow the system to supply<=the required minimum outdoor air , 14 rate with a single set-point f adjustment.,or c)system ." includes exhaust air energy recovery complying with Section <' >g„ 6.5.6.1. 6.5.3.3 I Multiple zone VAV systems with ❑Complies See the Mechanical Systems list [ME42]3 DDC of individual zone boxes ❑Does Not for values. have static pressure setpoint reset controls. ['Not Observable ❑Not Applicable W. High Impact(Tier 1) 2 1Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Crescent Grove Report date: 10/20/20 Data filename: Page 9 of 14 Section Mechanical Rough-ln Plans Verified Field Verified # Inspection ;, Value Value Complies? Comments/Assumptions & Req.ID 6.5.3.3 Multiple zone VAV systems with s• ) • ❑Complies See the Mechanical Systems list [ME4213 DDC of individual zone boxes = .s 1` - ❑Does Not for values. have static pressure setpoint '1i ^> "" —� reset controls. ; :, • Not Observable ri - ❑Not Applicable 6.5.3.3 Multiple zone VAV systems with j ❑Complies See the Mechanical Systems list [ME4213 :DDC of individual zone boxes f ❑Does Not for values. have static pressure setpoint !• ❑Not Observable reset controls. 4- ;,, ,; ❑Not Applicable 6.5.3.3 Multiple zone VAV systems with I ❑Complies See the Mechanical Systems list [ME42]3 DDC of individual zone boxes EDoes Not for values. ;have static pressure setpoint ❑Not Observable ;reset controls. r. ❑Not Applicable 6.5,4.2 HVAC pumping systems with >= , '❑Complies [ME2513 3 control values designed for ' ❑Does Not variable fluid flow(see section , details). ONot• ❑Not Applicable e 6.5.6.1 Exhaust air energy recovery on ' Y, • ❑Complies [ME56p systems meeting Tables 6.5.6.1- f; ❑Does Not 1, and 6.5.6.1-2. ONot Observable =1❑Not Applicable 6.5.7.1 Conditioned supply space , ' "' mm PP Y air to ❑Complies [ME10012 with mechanical exhaust<=the ❑Does Not greater of criteria of supply flow, ❑No[Observable required ventilation rate,exhaust , flow minu the available transffer a".'❑Not Applicable air(see section details). 6.5.7.1 Conditioned supply air to space ❑Complies [ME100]2 with mechanical exhaust<= the ❑Does Not greater of criteria of supply flow, Not Observable required ventilation rate,exhaust ❑ flow minu the available transffer DNot Applicable air(see section details). 6.5.7.1 Conditioned supply air to space ❑Complies [ME100]2 :with mechanical exhaust <=the ODoes Not ,greater of criteria of supply flow, Not Observable 'required ventilation rate, exhaust ❑ -flow minu the available transffer .y w p.. -, ❑Not Applicable ,air(see section details). 6.5.7.1 'Conditioned supply air to space .,i❑Complies [ME1O012 with mechanical exhaust<=the ❑Does Not greater of criteria of supply flow, required ventilation rate, exhaust l' [Not Observable flow minu the available transffer ❑Not Applicable air(see section details). 6.5.7.2.1 'Kitchen hoods>5,000 cfm have ❑Complies [ME3212 make up air>=50%of exhaust ❑Does Not air volume. ''-"" ,x_ [Not Observable v , 5 ❑Not Applicable 6.5.7.2.4 ;Approved field test used toi ❑Complies (ME49]3 evaluate design air flow rates ❑Does Not and demonstrate proper capture !` and containment of kitchen [Not Observable exhaust systems. ❑Not Applicable 6.5.8.1 Unenclosed spaces that are ❑Complies [ME34]2 heated use only radiant heat. ❑Does Not ['Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Crescent Grove Report date: 10/20/20 Data filename: Page 10 of 14 f e Section Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID 10.4.1 Electric motors meet requirements ❑Complies [EL912 where applicable. ODoes Not ONot Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Crescent Grove Report date: 10/20/20 Data filename: Page 12 of 14 Section # Final Inspection Complies? Comments/Assumptions &Req.1D 6,4.3.1.2 Thermostatic controls have a 5 °F ❑Complies (F13]3 deadband. DDoes Not DNot Observable ❑Not Applicable 6.4.3.2 Temperature controls have setpoint ❑Complies [F120]3 overlap restrictions. DDoes Not DNot Observable DNot Applicable 6.4.3.3.1 HVAC systems equipped with at least ❑Complies [FI21]3 one automatic shutdown control. DDoes Not DNot Observable DNot Applicable 6.4.3.3.2 Setback controls allow automatic ❑Complies [F12213 restart and temporary operation as DDoes Not required for maintenance. DNot Observable DNot Applicable 6.4.3.5 Heat pump controls prevent ❑Complies (Fl5)3 supplemental electric resistance heat ❑Does Not from coming on when not needed. DNot Observable DNot Applicable 6.4.3.5 ;Heat pump controls prevent ❑Complies fF1513 supplemental electric resistance heat DDoes Not from coming on when not needed. DNot Observable ❑Not Applicable 6.4.3.5 Heat pump controls prevent ❑Complies [F1513 supplemental electric resistance heat DDoes Not from coming on when not needed. DNot Observable DNot Applicable 6.4.3.5 Heat pump controls prevent ❑Complies [F1513 supplemental electric resistance heat DDoes Not from coming on when not needed. DNot Observable DNot Applicable 6.4.3.6 ;When humidification and ❑Complies [FI613 dehumidification are provided to a DDoes Not ;zone, simultaneous operation is prohibited.Humidity control prohibits DNot Observable :the use of fossil fuel or electricity to DNot Applicable produce RH > 30%in the warmest zone humidified and RH < 60%in the a coldest zone dehumidified. 6.7.2.1 Furnished HVAC as-built drawings ❑Complies [FI7]3 submitted within 90 days of system DDoes Not acceptance. DNot Observable DNot Applicable 6.7.2.2 Furnished O&M manuals for HVAC ❑Complies (F18]3 systems within 90 days of system DDoes Not acceptance. ['Not Observable IONot Applicable 6.7.2.3 An air and/or hydronic system ❑Complies [FI9]1 balancing report is provided for HVAC DDoes Not systems serving zones>5,000 ft2 of conditioned area. ❑Nat Observable DNot Applicable 1 High Impact(Tier 1) ['*': Medium Impact(Tier 2) 3. Low Impact(Tier 3) Project Title: Crescent Grove Report date: 10/20/20 Data filename: Page 13 of 14 Section # Final Inspection Complies? Comments/Assumptions & Req.ID 6.7.2.4 HVAC control systems have been ❑Complies IFI10]1 tested to ensure proper operation. ❑Does Not calibration and adjustment of controls. ['Not Observable ❑Not Applicable 10.4.3 Elevators are designed with the ❑Complies (F124V proper lighting,ventilation power, and ❑Does Not standby mode. [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) p,Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Crescent Grove Report date: 10/20/20 Data filename: Page 14 of 14