Loading...
Permit CITY OF TIGARD MASTER PERMIT s COMMUNITY DEVELOPMENT Permit#: MST2021-00149 T 1 GARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 Parcel: 2S107AA14200 Jurisdiction: Tigard Site address: 16611 SW SUNSHINE COAST ST Subdivision: ROSHAK RIDGE Lot: 142 Project: Polygon at Roshak Ridge, Lot 142 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 5 First: 1215 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 28 Bathrooms: 3 Second: 1715 sf Garage: 485 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2930 sf Value: $382,233.30 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amplvoll 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2930 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $43,640.75 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: nattyVary V e'w Permittee Signature:ege 0 vt/Applicati,on Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept In a conspicuous place on the job site until completion of the project. Approved plans are required on the Job site at the time of each Inspection. r . Building Permit Application 13—'e{115 2- Residential RECEIVE I FOR OFFICE USE ONLY Received/1C� • - City of Tigard APR " ` Dateived/ • !9 262! PermtNaM S f7D21-Od!4y III13125 SW]Tall Blvd.,Tigard,OR 97223 Plan Review ylo�,7 i Q,q. C A�l�OOOq Phone: 503.718.2439 Fax: 503.598.1960 Date/By: / / A U d OtherPermi4) L Inspection Line: 503.639.4175 CITY OF TIUHNL Date Ready/By: tom: H See Page 2for TIGARD g g BUILDING DIVISION �S /i T pp Internet: www.ti azd-or.goy Notified/Method: �� ' Supplemental Information TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ®New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application.Valuation: $ 362;A I d r ll ® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building 0 Multi-family Number of bedrooms: 5 0 Master builder ❑Other: Number of bathrooms:3 JOB SITE INFORMATION AND LOCATION Total number of lloors:2 31-i ( Job site address: 16611 SW SUNSHINE COAST ST New dwelling area: 2,930 square feet i S City/State/ZIP:Tigard, OR 97140 Garage/carport area: 485 square feet I 115 Suite/bldg./apt.no.: Project name:Polygon at Roshak Ridge Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Polygon at Roshak Ridge Lot no.: 142 Permit fees*are based on the value of the work performed. Tax map/parcel no. Indicate the value(rounded to the nearest dollar)of all __ equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. New residential construction: SFU Valuation: $ Elevation: 222300BR Existing building area: square feet Scheduled construction start: July 2021 New building area: square feet ® PROPERTY OWNER 0 TENANT Number of stories: Name:Polygon Homes WLH LLC Type of construction: Address:703 Broadway St., Ste 510 Occupancy groups: City/State/ZIP:Vancouver, WA 98660 Existing: Phone:(360 946 8674 Fax:( )360 693-4442 New: El APPLICANT ❑ CONTACT PERSON u9 BUILDING PERMIT FEES* Business name:Polygon Homes WLH LLC (Please refer mfee s¢heduleJ Structural plan review fee(or deposit): Sp 3c' Contact name:Omar Alami Abouhafs FLS plan review fee(if applicable): Address:703 Broadway St., Ste 710 Total fees due upon application: City/State/ZIP:Vancouver,WA 98660 Amount received: Phone:( 360 946 8674 Fax::( ) E-mail: PermitSubmittalsc�taylormorrison.com_OAlamiAbouhafs@taylormorrison.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* CONTRACTOR Commercial and residential prescriptive installation of roof-top mounted PhotoVoltaic Solar Panel System. Business name:Polygon Homes WLH LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:703 Broadway St., Ste 510 Solar Installation Specialty Code checklist. Permit Fee(includes plan review $180.00 City/State/ZIP:Vancouver, WA 98660 and administrative fees): Phone:( 360) 695-7700 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:207247 Total fee due upon application: $201.60 Authorized signature: Qom,.AEamtz: 46e_, This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Omar Alami Abouhafs Date: 04/14/2021 *Fee methodology set by Tri-County Building Industry Service Board. L\Building\Permits1BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) A Mechanical Permit ApplicataF C E I VE 1 FOR OFFICE USE ONLY City Tigard Ti and Received 4q ,00 t 't 13125 SW Nall Hlvd.,Tigard,OR 97223 APR 1 v 9 I]�f Date/By: Permit No.: �,t, 'b Zl _ Plan Review Phone: 503.718.2439. Fax: 503.598,1960 Datc/By: Other Permit: iltiAl;U inspection Line: 503.639.4175 CITY OFTIGARD DateReady/ByIwis: S See Page 2 for Internet www.tigard-or.gov BUILDING DIVISIOf�! Notified/Method! Supplemental Information TYPE OF WORK COMMERCIAL FEE* SCHEDULE-USE CHECKLIST Mechanical permit fees*are based on the value of the work ►:4 New construction 0 Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all 0 Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. Value:S CATEGORY_OF CONSTRUCTION RrSIDE�lIALEQUr1'MErT/SYSTEMS FEES' ®1-and 2-family dwelling ❑Commercial/industrial 0 Accessory building For spedai information use checklist. 1 j Multi-family ❑Master builder El Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heatina/cooling: Job site address: 16611 SW SUNSHINE COAST ST Air conditioning 46.75 Furnace 100.000 BTU(ducts/vents) 46.75 City/State/ZIP:Tigard,OR 97224 Furnace 100,000+BTU(ductsPoets) 54.91 Suite/bldg./apt_no.: Project name: Polygon at Roshak Ridge Heat pump 61.06 Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or bydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Polygon at Roshak Ridge Lot no.: 142 Other 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 33.39 Flue vent for water beater or gas New SFU fireplace 23.32 Loa lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 Other: 23.32 IN PROPE1.TY OWNER 0 TENANT Environmental exhaust and ventilation: Name:Polygon WLII,LLC Range hood/other kitchen Address:703 Broadway St.,Ste.510 equipment 33.39 Clothes dryer exhaust 33.39 City/State/ZIP:Vancouver,WA 98660 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(360)695-7700 Fax:( ) Attic/crawlspace fans 23.32 ® APPLICANT 0 CONTACT PERSON Other: 23.32 Business name:Polygon WLH,LLC Fuel piping: S14.15 for Qrat roar;S4.03(or each additional Contact name:Tonja Morris Furnace,etc. 1 Address:703 Broadway St.,Ste 510 Gas beat pump Wan/suspended/unit heater City/State/ZIP:Vancouver,WA 98660 Water heater Phone:(360)695-7700 Fax::(360)693-4442 Fireplace Range , E-mail:permitsubmittalsttaylormorrison.com 1 Barbecue iNk CONTRACTOR Clothes dryer(gas) Other: Business name:Pro Heating&Cooling MECHANICAL PERMIT FEES' Address: NW Aiociek Dr,Ste.1104 Subtotal . City/State/ZIP:Hillsboro,OR Minimum permit fee($90.00) Plan review(25°A of permit fee) Phone:(360)270-1590 Fax:( ) State surcharge(12%of permit fee) CCB lie.:209001 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within ISO e`-a bU days after it has been accepted as complete. Authorized signature: " R�'n • Fee methodology set by Tri-Count}Building industry Service Board Print name:Ella Duran Date: 10/30/20 Painildj p n,o,U,Wr F.mma.rnn Wm11 An,. Electrical Permit Application RECEIVE FOR OFFICE IF ONLY City of Tigard 1 r. 9 A2 Received Peca;ta Ml ST p2.1'COl 13125 SW Ran Blvd,Tigard,OR 97223 APR. , r, . 2,, Phone: 503.718,2439 Fax: 503,598,1960 �y w Related Permit a: IlupcctinLine: 503.6394175 CITY OF TIGARC ReedyDntday lads: 21 See Page 2for Eli.;ARD Internet: www.tlgard-or.gov NotifiediMedwd: Supplemental Information Prll!:[SING nlvisi lc', TYPE OF WORK • PLAN REVIEW El New construction ❑Addition/alteration/replacement Please check all that apply(submit J sets of plans wlitems checked): ❑Demolition ❑Other: ❑ k Sasiee or crkr 400or amps or me 0 Beddin n g ovrs three stones" where the available Sault cmrmt ❑Marinas and boatyards CATEGORIC OF CONSTRUCTION eacocds 10,000 amps at 150 volts or ['Floating buildings j t-and 2-family dwelling 0 Commercial/industrial ❑Accessory building Ion to Fad,or exceeds 14 000 0 Commercial-also agricultural r. antes for as other installations. bud dings. ng,. ❑Multi-family ❑Master builder 0 Othe 0 Fvc pump. ❑installation of 154 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system- larger separately derived Job#: Job site address: 16611 SW SUNSHINE COAST ST 0 Addition of new motor load of &ysnm mow nr more. ❑"A"`E""1 Z""1-3" City/State/ZIP: Tigard,OR 97140 ❑Six or more residential units occupancy ❑fkalthcare facilities ❑Recreational vehicle Parks. Suite/bldgiapt-#: Project name: Polygon at Roshak Ridge ❑llazardaus location., 0 Supply voltage rot our than ❑Service or feeder 600 amps or more. 600 cells nonsioat Cross street/directions to job site: FEE SCHEDULE Description I Qt., I rash I Total 1 . New residential single-or multi-family dwelling malt. Subdivision:Polygon at Roshak Ridge Lot#: 142 Includes attached garage. Tax map/parcel#: 1,1300 an R or less _ 168 54 4 Es add'1500 sq.It.or portion 33.92 1 DESCRIPTION OF'WORK Limited energy,residential (with above sq.R) 75 00 2 New construction.Type SFU Limited energy,multi-family residenbal(with above sq.R) 75.00 2 ® PROPERTY OWNER I 0 TENANT Renewable Energy ❑ Sec Page 2 Services to feeders installation,alteration,and/or relocation Name: Polygon Homes WLHLLC 200 amps or less _ 100.70 2 Address: 703 Broadway St.,Ste 710 201 amps to 400 amps 133.56 -2 401 amp&to 600 amps 200.34 2 City/SlateJLIP: Vancouver,WA 98660 601 amps to 1,000 amps 301.04 2 Phone:(360 )946 8674 Fax:( ) ever 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: 0AlarniAbouhaLs@taylonnorrison.com com-PermmitSubmittals(1Ltaylormorrison.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: ___ Date: 401 amps to 599 amps 168.54 2 ❑ APPLIC:ANT . I ❑ CONTACT PERSON Branch circuits-new,alteration,or extension,per panel A.Fee for branch circuits with Business name: Polygon Homes WI.H LLC above service or reeler fee, 7 42 each branch oireuit - Contact name: Omar Alarm Abouhafa B.Fee for branch circuits without Address: 703 Broadway St.,Ste 710 s ee Cuit fee,first branch ctrh uit 56 18 2 _ City/State/21P:Vancouver,WA 98660 Eachaakl'1 branch circuit 7.42 2 phone:(360 )946 8674 Fax: Miscellaneous(service or feeder not included) ( ) Each manufactured or modular 67.84 2 Email:OAlamiAboubafs lolmon ison.com-Pemli1Submittal dwelling,service aodlor renaC[ flay S(Q1layluiTnOf[t.SOn-coo Rmcaranccr only 67 84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business nim,p: Wallace Electric Sian or outline lighting 67.84 .2 Sign nr Signal eutt(s)or lunited 8'i Address: 105 Dresden St 0 See Page 2 2 parcel,aherabon,or extension. City/State/ZIP: Astoria OR 97103 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66 25/tar Phone:(503 3118 0563 Fax:( ) Investigation(I ltr min) 90.00/hr Email: David@wallaccwires.com Industrial plant(I tar to n) 78.I8/tar Inspections for which nu fee is 90. 00/la CCB ire.:224868 F3ectrical Lie.: C1441 Suprv.Lie.: 6363S specifieafy listed(14 hr min) ELECTRICAL:PERM1T'FEES :' Suprv.Electrician signature,required: Subtotal Print name:"DAy 4pLe. Date: ,r/4 F/z/ 0 Plan Review Required(25%of permit Mc): . / S State surcharge(12%ofpanditfee): Authorized signature �!,ta"" - TOTAL PERMIT FEE: This permit application expires If a permit is not obtained within 1.80 Print n_a_ e: 0 t jai I a, Date: zt ', a-t.. ,lays a0ter It has been accepted as complete. --- T ......... , Number of inspections allowed Psi per permit. L+Emile$Og'H4rmuetiLC_IkmudApp_F7.R FRF..dcc lies 06u1771011 4 G9(i15T(,1NSrCOMiWEB Plumbing Permit Applicatio�ECEIVE D Building Fixtures FOR OFFICE USE ONLY City of Tigard APR 1 F 2021 [ .1n . g U Received Permit No.:NST2O2.141U1L.f , n 13125 SW Hall Blvd.,Tigard,OR 97223 plan Review ill Phone: 503.7182439 Fax: 503.598.196�ITY OF TIGARD Uatrl6y: Other Permit No.: TIGARD Inspection Line: 503.639.4175 BUILDING DIVISIO\Pate Ready/By: Arms: ® See Page for Internet: www.tigard-or.gov Notified/Method: Supplemental Information TYPE OF WORK FEE* SCHEDULE ®New construction ❑Demolition For suede!information use checklist Description I Qty. I Ea. I Total 0 Addition/alteration/replacement ❑Other: New 1-2-fanilly dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312.70 ,l-and 2-family dwelling ❑Commercialindustrial SFR(2)bath 437.78 ❑Accessory building WA•Multi-fantily SFR(3)bath 500.32 Each additional bathikitchen 25.02 ❑Master builder ID Other: Fire sprinkler( sq.ft.) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: Job site address: 16611 SW SUNSHINE COAST ST Catch basin or area drain 18.76 City/State/ZIP:Tigard,OR 97224 D ywell,leach line,or trench drain 18.76 Footing drain(no.linear ft.:, ) Page 2 Suite/bldg./apt.no.: I Project name:name:•RiaohellailesPolygon at Roshak Ridge Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 Rain drain connector 18.76 . Sanitary sewer(no.linear ft.:_) Page 2 Storm sewer(no.linear ft.:_) Page 2 Water service(no.linear ft.: ) Page 2 Subdivision: Polygon at Roshak Ridge ( Lot no.: 142 Fixture or item: Tax map/parcel no.: Backflow preventer 31.27 DESCRIPTION OF WORK Backwater valve 12.51 New SFU Clothes washer 25.02 Dishwasher 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 ID PROPERTY OWNER I 0 TENANT Expansion tank 12.51 Name:Polygon WLH,LLC Fixture/sewer sewer cap 25.02 Floor drain/floor sink/hub 25.02 Address:703 Broadway St.,Ste 510 Garbage disposal 25.02 City/State/Z1P:Vancouver,WA 98660 Hose bib 25.02 Phone:(360)695-7700 Fax:( ) Ice maker 12.51 ® APPLICANT 0 CONTACT PERSON Interceptor/grease trap 25.02 Business name:Polygon WLH,LLC Medical gas(value:$ ) Page 2 Primer 12.51 Contact name:TonJa Morris --- - Roof chain(commercial) 12.51 Address:703 Broadway St.,Ste 510 Sink/basin/lavatory 25.02 City/State/ZIP:Vancouver,WA 98660 Solar units(potable water) 62.54 Phone:(360)695-7700 Fax::(360)693-4442 Tub/shower/shower pan 12.51 E-mail:permitsubmittals®apolygonbomes.com Urinal 25.02 Water closet 25.02 CONTRACTOR Water heater 37.52 Business name:G&B Plumbing&Sons Inc Water 8/D t in WV 56.29 P P Address:P.O.Box 92 Other: 25.02 City/State/ZIP:St.Paul,OR 97137 Subtotal Phone:(503)868-1417 Fax:(971)727-8170 Minimum permit fee: 572.50 CCB Lie.:184372 Plumbing Lic.no.:pb634 Plan review (25%of permit fee) State surcharge(12%of permit fee) Authorized signature: litatit e ` TOTAL PERMIT FEE Print name:Steve Fowler Date: 10/30/20 This permit application expires if a permit is not obtained within 180 clays after it has been accepted as complete. "Fee methodology set by Tri.County Building Industry Service Board. 1:sBuitd,gtPermin5PLFN-PermitArp.dne I0/01A9 4404616T(t0'00C0MwE81 Plan # ,Th227:6be>e, Floors Large 2.,0 Bed rooms S Small 53 We lS LAV S Tub y Basement _ Vent 5- 1st Floor 1. 2-I 5 Water Heater 2nd Floor 1 7 )5 AC r 3rd Floor 2School R-3 Total Z-7 J�Garage Li (6 S PC r4.._ e i.zrr,� 3 t �T�-f-- Total 3y l� �� ' #for Elec s City of Tigard 4 COMMUNITY DEVELOPMENT DEPARTMENT ■ T 1 G A R D Building Permit Review — Residential Building Permit #: KA ST'2021 -O0 j 49 Site Address: 16611 SW Sunshine Coast Project Name: Polygon at Roshak Ridge Lot #: 142 dPlanning Review P oposal: New single detached house Verify address/suite#active in Accela. In River Terr e: ❑ No Yes, River Terrace Review Addendum Si Plan Elements: V r..ion Control copies of site plan on 8-1/2"x 11"or 11 x 17"paper 'i 4 tamed trees with drip line and tree protection measures rawn to scale(standard architect or engineer scale) otprint of new structure (including decks)and FFE rth arrow 1/ lity locations&easements(required for new and additions) e address,project or subdivision name and lot number tt alk/driveway approach pplicant information(name and phone number) . A.cation of wells/septic systems t dimensions and building setback dimensions = e t tree size,type and location quare footage of buildings to be demolished reet names xisting structures on site y omer elevations(2'contours if more than 4'diffe -ntial t area,building coverage area,percentage of coverage and >1,000 sf of impervious area created or replace.? FA es o impervious area (applicable if R-7,R-12,R-25&R-40) If yes,is a storm water quality facility shown , I es o 0 Clean Water Services —Service Provider Lett (lot platted prior to 9/10/1995): Required: ❑Yes,applicant was notified LJ No Received: ❑ Yes ❑ No •d Water Meter Fixture Unit Worksheet—Addi ns, Remodels and ADUs \ / Required: ❑Yes,applicant was notified No Received: ❑Yes 0 No DC Exempti for ADU applied for: ❑ Yes I 1 No VReceived: El Y s ❑ No I d Public Facili s Improvement(PFI) Permit: iiequired: Yes,applicant was notified ❑ No plied For: Yes El No,stop intake and Use Case #: SUB201quired Setbacks: Front:5-00004 equired �d Zoning: R-4.5 8 Rear: 10 Side: 3 Street Side: N/A Garage: 20 Building Height: Max. Height: N/A Actual Height: 1 , dscape Area: % ❑ Lot Coverage A ax: Entrance 1 Set back no more than 8'from street-facing wall P arallel to street or offset 45 degrees or less Windows I 12%of area of all street-facing facades Garage I Gara e door is .- -:.d widest street-facing w. ❑ Yes ❑ No,one of the following is met: Door extends no mo - -.,n 5'f • wall and there is a covered porch extending beyond garage. Door extends no more . wall and there is a 12 sq ft.window above garage on 2nd floor. ❑ Gara•e door width is 1 12'or less 51' . - less of facade 60%or less and includes 7 of following: I•Covere• :.rch I Recessed entrance I W.i . et ❑ 1'Roof eave Roof offset I . - shingles I Lap Siding ❑ Roof itch I a - . .,or gambrel roof ❑ Dormer a Accent siding I Window trim LiWmdow recess I .: . •rojection ❑ Balcony '' II V'sual Clearance I7 Urban Foxes Ian I4 ensitive Lands: ❑ Yes No Type: Co..itions met prior to issuance of building permit No -s: 1, Approved By Planning: — • Date: C%2 Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved 0 Not Approved 1:\Building\Forms\BI dgPerm itRvwRE S_122419.docx Building Permit Submittal r Original Submittal Date: DV/I5/2624 Site Plans: # ---- Building Plans: # 3 Building Permit#: Et Enter buildingpferrmit#above. �� � Workflow Routing: ❑ Ur-Engineering Engineering E Permit Coordinator L� iuilding Workflow Sign-off: ign-off for Planning(include notes from planning review) Route Application Documents: EkEngineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. ❑ Building: original permit application,site plans,building plans,engineer and beam calculations d trust details,if applicable,etc. Notes: By Permit Technician: Date: 40 g/2021 En: *neering Review A Slope at building pad: 2.t. 114 Conditions "Met"prior to issuance of building permit ,U7i7 aEasements (encroachments) per engineering conditions of approval and plat Water Quality/Quantity Facility: � Assess Water Quality Fee in-lieu: ❑ Yes L�'/No Assess Water Quantity Fee in-lieu: ❑ Yes �2 L�J No / LIDA Facility on lot: ❑ Yes No " Final Plat Recorded: ❑ NOT Approved by Engineering: Date: Notes: l Approved by Engineering: _/�� Date: WhrZ./ Revisions (after Building Submittal only Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Permit� Coordinator Review �/� Conditions "Met" prior to issuance of building permit ❑ Approved, NOT Released: Date: Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: 'SDC Exemption: ❑ Received Does not aIjly ,Er SDC Fees Entered: Wash Co Trans Dev Tax: gYes IJ N/A Tigard Trans SDC: Yes ❑ N/A Parks SDC: elaYes ❑ N/A LIDA ❑ Yes )2(N/A AOK to Issue Permit Approved by Permit Coordinator: Date: L{(2,40 L\ 1:1Building\Fortes\B I dgPerm itRvw_RE S_122419.do cx 4 City of Tigard r COMMUNITY DEVELOPMENT DEPARTMENT TIGARD River Terrace Building Permit Review Addendum Building Permit #: 1-f$T2OZ/-OO ( LIg Site Address: U ( '// SW Sunshine Coast St Project Name: Polygon at Roshak Ridge Lot #: 142 (New dwelling=subdivision name;Addition or Alteration=last name of owner) Planning Review of River Terrace Plan District Design Standards (18.640.070.1): Is the project subject to the plan district design standards? ElYes ❑No 1. Articulation: a minimum of 1 element per each street-facing facade that has 30-60 ft. of frontage.An additional element require for lots with over 60 ft. of street frontage shall be provided every 30 ft. Balcony w/ access 2 Window Projection Vertical Wall Offset a Porch min. 5 t. deep ft. deep min. 2ft., 5 ft.wide min. 2 ft., 6ft.wide Gabled dormer ❑ ❑ ❑ ❑ 2. Eyes on the street: a minimum of 12 of each street facing facade must include windows or entrance doors. Percentage Shown: > ) U 3. ntrances:At least one entrance must meet both of the folio ing standards: Max. 8 ft. setback from lon st street- facing wall Parallel to street,angle no more than 45° from street, or o en onto porch En ance opens to a porch: Yes ❑No If ,all the following apply: - sq.ft. min. ne street facing entry 2 ft. max. roof above floor of porch 5 ft. depth min. 30%min. porch roof coverage 4.etailed Design:All buildings shall include a min. of five of the following elements on all street-facing facades: overed porch min. 5 ft.wide x 5 ft. deep CI Recessed entry area min. 5 ft.wide x 2 ft. deep _}fall offset min. 16 inches CI Dormer min. 4 ft.wide Roof eave min. 12 inch projection ❑f�oof offset min.of 2 ft. ❑Roof shingles either tile or wood ® able,hip or gambrel roof design ❑Roof pitch oriented south min. 500 sq. ft. Horizontal lap siding min. 3-7 inches wide ❑Accent siding min. 40%of street facade [Window trim min. 2 '/2"wide by 5/8"deep ❑Window recess min. 3 inches for all street facing ❑Bay window min. 5 ft.wide by 2 ft. deep ❑Balcony min. 5 ft.wide x 3 ft. deep with inside access ❑Attached garage is 35% or less of street facade 5. Garages and Carports:May face the front or side lot line on a co r lot. Setbacks: No closer to front or side lot line,than longest street-facing wall. Yes ❑No. If No (Check one): 0 May extend up to 5 ft. if there is a covered front porch and garage does not extend beyond the front porch. ❑May extend up to 5 ft.where the garage is part of a two-story building and there is a window at the second story above the garage that faces the street with a min. area of 12 sq.ft. Width: (Check one) ❑12-foot-wide garage door 40% max. of street facade ❑50%max. of street facade with 7 detailed design elements Notes: Approved By Planning: -, Date: 171 ./ 1:\Building\Porms1BI dgPer nitRvw_RES_RT_121417.docx