05-May CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2021-00154 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05l0312021 Parcel: 2S114BC04600 Jurisdiction: Tigard Site address: 10483 SW BONANZA WAY Subdivision: RIVERVIEW ESTATES NO.2 Lot: 83 Project: Bouer Project Description: Kitchen remodel, remove nonbearing partition wall, replace 6ft window with Eft slider BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 15 Smoke Dwelling Units: 0 Third: 0 sf Right: 5 Detectors: Total: 0 sf Value: $35,000.00 Rear: 10 PLUMBING Sinks: 1 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 0 Tubs/Showers: 0 Garbage Disp: 1 Water Heaters: 0 Water Lines: 0 Drains: Catch Basins: 0 BckBw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Tvoes Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 1 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea addl 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 12 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System. N Garage Opener: N All N Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB Owner: Contractor: BAUER,ERICH R& NORTHLAND DESIGN&BUILD Required Items and Reports(Conditions) BAUER,TAMARA L 20000 SW CAPPOEN RD 10483 SW BONANZA WAY SHERWOOD,OR 97140 TIGARD,OR 97224 PHONE: PHONE: 503-380-6251 FAX: 503-625-4838 Total Fees: $1,321.71 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Holly OvLA licatfo Issued By: Van/1��lVe�e Permittee Signature: rr vt Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. City of Tigard a COMMUNITY DEVELOPMENT DEPARTMENT T I G A R D Building Permit Review — Residential Building Permit #: M 5T 2021 -00 i Gja, Site Address: 1 Oy g 3 $W Son A•r z.A► wAY Project Name: V _ Lot #: Planning Review st.> l Proposal: K1Tz�tt-r� ReXhoP GL (I ur+e�21o2� No( p CPrAvue e To 'F"-onTf-'fl m— XI-Verify address/suite #active in Accela. ❑ In River Terrace: .YJ -No D Yes, River Terrace Review Addendum Site 1an Elements: Erosion Control opies of site plan on 8-1/2"x 11"or 11 x 17"paper Retained trees with drip line and tree protection measures 0D awn to scale(standard architect or engineer scale) Footprint of new structure(including decks)and FFE lig�North arrow Utility locations&easements(required for new and additions) C,�JSite address,project or subdivision name and lot number Sidewalk/driveway approach V r.pplicant information(name and phone number) Location of wells/septic systems Lot dimensions and building setback dimensions Street tree size,type and location Square footage of buildings to be demolished Street names Existing structures on site Corner elevations(2'contours if more than 4'differential) Lot area,building coverage area,percentage of coverage and >1,000 sf of impervious area created or replaced? EYes ENo impervious area(applicable if R-7,R-12,R-25&R-40) If yes,is a storm water quality facility shown? EYes ❑No 0- .l�J Clean Water Services—Service Provider Letter (lot platted prior to 9/10/1995): Required: ❑ Yes,applicant was notified , "'No Received: ❑ Yes ❑ No D Water Meter Fjxture Unit Worksheet—Additions,Remodels and ADUs Required: , Yes,applicant was notified XNo R,.e.,iv N ❑ SDC Exemption for ADU applied for: ❑ Yes J�o -- d Y• ❑ es ❑ No b,� ZrPublic Facilities Improvement(PFI) Permit: Required: ❑ Yes,applicant was notified ,ENo Applied For: ❑ Yes ❑ No,stop intake $ Land Use Case#: w Aa ❑ Zoning: ❑ Required Setbacks: Front: 115— Rear: 10 Side: ' Street Side: If Garage: ?AS ❑ Building Height: Max. Height: 3 S' Actual He' ht: Ili/t4 Cif Landscape Area: IJA °A Lot Coverage Max: N/A Entrance ❑,_.,/Set back no more than 8'from street-facing wall ❑ Parallel to street or offset 45 degrees or less Windows JMinimum 12%of area of all street-facing facades*. Garage a door is behind widest street-facing wall ❑ Y No,one of the following is met: ❑ Door exten than 5'from wall and there' overed porch extending beyond garage. ❑ Door extends no more than 5' om ere is a 12 sq ft.window above garage on 2nd floor. ❑ Garage door width is ❑ 12' s ❑ 50%or less of aca 60%or less and includes 7 of following: ❑ Covered porch ecessed entrance ❑ Wall offset ❑ 1'Roo eav ❑ Roof offset ❑ Fire es ❑ Lap Siding ❑ Roof pitch 0 Gable,hip,or gambrel roof r �- Accent siding 0 Window trim ❑ Window recess ❑ Window projection ❑ Balcony j Visual Clearance kw Ip Urban Forestry Plan 115iti Sensitive Lands: �11t ❑ Yes 0 No Type: ❑ Conditions met prior to issuance of building permit No s:'� Exl s nn� 1&tfl O�I ON.-1 �J wAu.-Z`Di wine,Alma-) it, Reir+ait-1 Ur1U'hanGvEl yrtf Approved By Planning: Date: Revisions (after Building Submittal onl ) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved I:\Building\Forms\BldgPermitRvw_RES_122419.docx Building Permit Submittal Original Submittal Date: Ql///S/Ll/2/ Site Plans: # Building Plans: # 3 Building Permit#: Enter building permit#above. Workflow Routing: Planning Engineering LI'ermit Coordinator wilding Workflow Sign-off I /Sign-off for Planning(include notes from planning review) Route Application Documents: II/Engineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. Ltd'Building. original permit application,site plans,building plans,engineer and beam calculations an. t details,if applicable,etc. Notes: By Permit Technician: '/ � Date: d It CIZJ _ Engineering Review Ni-Slope at building pad: 2/ ''...-Conditions "Met"prior to issuance of building permit n l asements (encroachments)per engineering conditions of approval and plat N JN- ©/Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes Q�No Assess Water Quantity Fee in-lieu: ❑ Yes Gd -No LIDA Facility on lot: El Yes G2r'No <'Final Plat Recorded: n ❑ NOT Approved by Engineering: Date: Notes: te L�1 Approved by Engineering: ,Qyl/c,r,,,, Date: •q/2b/2C24 Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Permit Coordinator Review }.; Conditions "Met"prior to issuance of building permit ❑ Approved,NOT Released: Date: Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: SDC Exemption: ❑ Received A Does not apply ❑ SDC Fees Entered: Wash Co Trans Dev Tax: ❑ Yes 12' N/A Tigard Trans SDC: 0 Yes N/A Parks SDC: 0 Yes 121 N/A LIDA ❑ Yes N/A • g OK to Issue Permit Approved by Permit Coordinator: fy^ Date: 4I 20 I:\Building\Forms\BldgPermitRvw_RES_122419.docx * Building Permit Application '€3-415121 Residential RECEIVE'L.• FOR OFFICE USE ONLY City of Tigard Date/By:6/ ` G �2/ �" Permit No.: 31 /—CO I go:Plan — III 4 13125 SW Hall Blvd.,Tigard,OR 97223 Rview l APR 0 5 Y02 E �/�21) Other Permit Phone: 503.718.2439 Fax: 503.598.1960 DatelBey: u�6/ TIGARD Inspection Line: 503.639.4175 Date R ady/By: orris. El See Page 2 for Internet: www.tigard-or.gov CITY OF TIGARU Nd Ivle ho . ��� Supplemental Information y ,r TYPE OF WORK R'„ :I-AND 2-FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)or all Addition/alteration/replacemcnl ❑Other. equipment,materials,labor,overhead,and the profit for the CATEGORY OFCONSTRUCTTON ' ," work indicated on this application. j Valuation: $ I-and 2-family dwelling ❑Commerctabmdustrial l DOCK 0 Accessory building 0 Multi-family Number of bedrooms: 0 Master builder 0 Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 1 0 it 2 3 s L! .g a Izt G f t"Z Gr, kit), New dwelling area: square feet City/State/ZIP: "r'I aar� r o 2 g o a a 3 I Garage/carport area: square feet Suite/bldg./apt.no.: d Project name: 8 q c f Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet 1 'as t ,t > A:COMMERCIAL- --`. : i I W Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the � ppDESCRIPTION OF WORK work indicated on this application. K(IC,k,/6L ( e twci.,e I r It,Q U1 d�� 1'vtrti 4a(,. l� / Valuation: $ 10 or bile) Wol.� l�/l� c,C_ (� t.,r,u r� -,-A. �/ Existing building area: square feet CA CIL ff _ C I \Jl ( New building area: square feet ,12 PROPERTY OWNER 0 TENANT re Number of stories: Name: 7"-c4 IAA; E G tot r— Type of construction: Address: (t) ' 8 3 SL) Eo piu,.t2-c( e / Occupancy groups: (City/State/ZIP: 1 6 a rok t £ 9 . ?9 3 Existing: Phone:( ) Fax:( ) Nev: ----- PI ICANT 0 CONTACT PERSON l „ :,, BUILDING PERMIT FEES* 4/0 _ _ Please. refer to fee schedule) Business name: r 1-4/4,� � IA41-("ct)ot-t a"& 4)Pd! h IHC. ��/ �JU k(�� y I Structural plan review fee(or deposit): ` Contact name: r l q FLS plan review fee(if applicable): Address: c9;cosw Cq f d e k LetTotal fees due upon application: City/State/ZIP: Stu rwoo t t O. 9'71 9 0 p a Amount received: Phone:(60?) Oa7 — C(d [ Ct Fax::( ) / n / / PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* E-mail: �jfiuwlp /T�00rill it,r4cplt etc ctk' t4ilcl. rowt Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name:�p t f-�jIu J e„gfr,du�t Gve-' De.Cl�. . ruff, and Submit two(2)sets of roof plan with connection details �7 fire depmtutent access,along with the 2010 Oregon Address: a6OC>6 S LI C-a W.rt1 Solar Installation Specialty Code checklist. City/State/ZIP: S�fWC9od 10(Z g?('(p PermitFandaee cluddminesstrative lan view $180.00 Phone:(fob)) 01)) —4.D't q Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.: i na <-( 2 1� Total fee due upon application: $201.60 Authorized signature: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. r,) , *Fee methodology set by Tri-County Building Industry Print name: r a r t- Date: tql a �a I Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(l 1/02/COM/WEB) Building Permit Application Checklist , One- and Two-Family Dwelling FOR OFFICE USE ONLY City of Tigard Received II Perini[NoDate/ . q 13125 SW Hall Blvd.,Tigard,OR 97223 Associated led permits: Phone: 503.718.2439 Fax: 503.598.1960 24-Hour Inspection Line' 503.639.4175 El Electrical ❑ Plumbing 0 Mechanical TIGAR❑ Internet: www.tigard-or.gov ❑ Other THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW . Yes No N/A I Land use actions completed. See jurisdiction criteria for concurrent reviews. _ 0 ❑ ❑ 2 Zoning. Flood plain,solar balance points,seismic soils desi. ation,historic district,etc. _ 0 0 ❑ 3 Verification of approved plat/lot. ❑ ❑ ❑ 4 Fire district approval required. Name of district: ❑ ❑ 0 5 Septic system permit or authorization for remodel. Existing system capacity ❑ CI 6 Sewer permit. ❑ 0 0 7 Water district approval. ❑ 0 0 8 Soils report. Must carry original applicable stamp and signature on file or with application. 0 ❑ 0 9 Erosion control 0 plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- ❑ ❑ ❑ basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state ❑ 0 0 building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if 0 0 ❑ there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ ❑ ❑ and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑ 0 0 furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ 0 ❑ floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ ❑ ❑ Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- 0 ❑ ❑ prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing ❑ ❑ ❑ locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ 0 El systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists 0 ❑ 0 over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. 0 ❑ ❑ 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required 0 ❑ 0 for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ 0 0 architect licensed in Ore.on and shall be shown to be ap plicable to the Iro'ect under review. JURISDICTIONAL SPECIFICS 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". 0 ❑ ❑ 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. 0 ❑ ❑ 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. ❑ 0 ❑ 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. ❑ ❑ ❑ 27 "Drawn to scale"indicates standard architect or engineer scale. ❑ 0 0 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ ❑ 0 Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines,. ❑ 0 0 and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑ 0 including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. 1:1Building\Permits1BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Mechanical Permit Application FOR OFFICE USE ONLY �/� /I City of Tigard RECEIVE Date/By. PermitNo.:N5T202!--0015c . 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review vv Phone: 503.718.2439 Fax: 503.598.1960II APR 0 5 20Z3 Date By: Other Permit: TIGARD Inspection Line: 503.639.4175 Date Ready/By: dues: El See Page 2 for Internet: www.tigard-or.gov CITY OF TIGARD Notified/Method: n Supplemental Information TYPE OF WORK COMMERCIAL FEE* SC 1 Ii USE CHECKLIST Mechanical permit fees*are based on the value of the work ❑ New, construction Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑ Demolition ❑ Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ I sew CATEGORY OF CONSTRUCTION ION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* [ 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building For special infor,uarion Ilse checklist. ❑'Multi-family ❑ Master builder ❑Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning 46.75 Job site address: 1 4 Ro Inv A 2,ci L,/a. Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: Missiar 6 4?,9 r�3 Furnace 100,000+BTU(ducts/vents) 54.91 1 Heat pump 61.06 Suite/bldg./apt.no.: Project name: g Q IiLR f Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 33.39 Flue vent for water heater or gas KILL_ fGwto •( I G ct ra� i ni , Vt` ✓.6,-4 fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 / „w. ,.,,-r Other: 23.32 PROPERTY OWNER ❑ TEIShI Environmental exhaust and ventilation: Name: QiMI Range hood other kitchen equipment 33.39 33.3q Address: Q C(2 3 O ti a A R t4.1 G Clothes dryer exhaust 33.39 City/State/ZIP: '� I. � Single-duct exhaust(bathrooms, I�a I d / (] aa toilet compartments,utility rooms) 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 APPLICANT 0 CONTACT PERSON - Other: 23.32 q� /J Fuel piping: Business name:!✓D ..i/C(b d US rt1( OI-1 U u� AS7�H 1^i_h C. $14.15 for first four;$4.03 for each additional Contact name: re G r t PGA: Furnace,etc. `� Gas heat pump Address: aO6da ..l,J Care:,Cr'l /C� Wall/suspended/unit heater City/State/ZIP: .l�.r r^W0 v d 1 Q(? 9-(tf Q Water heater Phone:((x ?) a a p- (o?q q dal ( ) Fireplace //lJ Range 1 14,l.f- E-mail: /]/Ia„i pe-tli�e_401-4/ou alIl/ " N 4r-tcfbw O ./avv.1 Barbecue Clothes dryer(gas) Other Business name: „f �! dd e- .S { "' d `�� MECHANICAL PERMIT FEES* Address: as y , S t .._ r I ( - Subtotal (7, 5'Li. p 7 Minimum permit fee($90.00) City/State/ZIP: } LI✓t K I 0/ 2 L [ 6 Plan review(25%of permit fee) Phone:(5 63) ''g- 7 - 41 (P 3 .. Fax:( ) State surcharge(12%of permit fee) CCB lie.: Cl I.t i 3 a TOTAL PERMIT FEE /2 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: ( * Fee methodology set by Tri-County Building Industry Service Board V Print name: 13,r � Pail, \J Date: Lrlal 1 I 103oilding\Permits\MEC_PermitApp_040113.doe 440-4617T(I 1/02/COM/WEB) Mechanical Permit Application - City of Tigard Page 2 - Supplemental Information Commercial & Multi-Family Fee Schedule: Total Valuation: , Permit Fee: $0.00 to$500.00 Minimum fee$69.06 $500.01 to$5,000.00 $69.06 for the first$500.00 and $3.07 for each additional$100.00 or fraction thereof,to and including $5,000.00. $5,000.01 to$10,000.00 $207.21 for the first$5,000.00 and $2.81 for each additional$100.00 or fraction thereof,to and including $10,000.00. $10,000.01 to$50,000.00 $347.71 for the first$10,000.00 and $2.54 for each additional$100.00 or fraction thereof,to and including $50,000.00. $50,000.01 to$100,000.00 $1,363.71 for the first$50,000.00 and $2.49 for each additional$100.00 or fraction thereof,to and including $100,000.00. $100,000.01 and up $2,608.71 for the first$100,000.00 and $2.92 for each additional$100.00 or fraction thereof. Note: All new commercial buildings require 2 sets of plans. 1:\Building\Permits\MEC_PermitApp_040113.doc 2 Electrical Permit Application FOR OFFICE USE ONLY RECEIVE MsT �-ooc5� City of Tigard Date/By: Permit 4: 13125 SW Hall Blvd.,Tigard,OR 97223 APR 0 5 2011 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Related Permit;*: Inspection Line: 503.639.4175 Ready Date/By: leri�s-tI gi See Page 2 for I I0,ARD CITY OF TIQARd Notified/Method: ,o, Supplemental Information e Internet: www.tigard-oi gov .lit pP TYPE t7F W(7RC ���' ''„ PLAN'REVIEW " ❑New construction Addition/alto rat ion/replacement Please check all that apply(submit_sets of plank n items checked): ❑Service or feeder 400 amps or more ❑Building over three stones. ❑Demolition E Other: where the available fault current ❑Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at ISO volts or 0 Floating buildings. I-and 2-family dwelling ❑Commercial/industrial ❑ Accessory building less to ground,or exceeds 14,000 El Commercial-use agricultural amps for all other installations. buildings. ❑ Multi-famih ❑ Master builder ❑Other: ❑Fire pump_ ❑Installation of 150 KVA or JOB SITE INFORly~AND LOCATION 0 Emergency system. larger separately derived " 0 Addition of new motor load of system. Job If: Job site address: lb 4 Li- 3o,,„„t act, �0 y 100HP or more. ❑"A" "E'° °'t-2° "1-3" "�'''• ( ❑Six or more residential units. occupancy. City/State/ZIP: i I&rd i 6 2. 9? a J. 3 0 Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name: 1 A u c - 0 Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Description I Oty, I Each I Total I ' New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 16854 4 Tax map/parcel#: y Ea-add'1500 sq.ft.or portion 33.92 I DE`', 'tt�(t.IIION OF;r / Limited energy,residential K �• /'t 11 L I a bru,a-4, C-J,(:U (with above sq.ft' 75.00 2 t Ct re(tit J Limited energy,multi-family 06 S P J✓i K Gr residential(with above sq.ft.) 75.00 2 ,r ,k ,° ,ROPERTY OWNER ,✓ r/ Renewable Energy ❑ See Page 2 . Services or feeders installation,alteration,and/or relocation Name: "ram i‘ 86[.lf F- 200 amps or less 100.70 2 Address: 2 t ]� 201 amps to 400 amps 133.56 2 D 9 `� `y w jar �'L� (jay 401 amps to 600 amps 200.34 2 City/State/ZIP: j q or 4 , C)f. 9'7aa 3 / 601 amps to 1,000 amps 301.04 2 Phone: ( ) V Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signat re: Date: 401 amps to 599 amps 168.54 2 ' ' (x; :ANT t- FACT PERSON Branch circuits-new,alteration,or extension,per panel / A.Fee for branch circuits with Business name: D f-`- /ti u lrl (/ ,,N.""' u�u, p� I e .1 NC' above service or feeder fee. Q B each branch circuit 7.42 2 Contact name: !J f,u LA. F . (/" B.Fee for branch circuits wirhotet Address: service or feeder fee,first 1 56.18 S t,/l 2 a0000 SW LaWO'1,v IZ� branch circuit City/State/ZIP: S ha2{Woad 1 v 12 9 7( cE 0 Each add'l branch circuit if 7.42 $j,G a, 2 Miscellaneous(service or feeder not included) Phone:(60?) )0)7 - CIRolVi. Fax: :( ) Each manufactured or modular 67.84 2 (i a e 1 dwelling,service and/or feeder �j -1T,��// @-no , -1, l,-J St y.-t uv�d �U ri Email: d CO 0-- Reconnect only 67.84 2 H CO /�CTOR " Pump or irrigation circle 67.84 2 ' Business name: Ca - vl L f e Clli L Sign or outline lighting 67.84 2 Signal circuit(s)or limited-cnergy 0 See Page 2 2 Address: Po eo)( g(,0 panel,alteration,or extension. Each additional inspection over allowable in any of the above City/State/ZIP: A pA CI y t 0 tc 9?t O r Additional inspection(I hr min) 66.25/hr Phone:(503) Lf'.1"-_ l(000 Fax:( ) Investigation(1 hr min) 90.00/hr E Industrial plant(1 hr min) 78.18/hr Email: �aufoAelc-C.11t_ � 4-6 (r.CD0.4 CU��/ - Inspections for which no fee is 90.00/hr CCB Lie.: r Ell 7/3 Electrical Lic.:pe_rat)c Suprv.Lico75-9 specifically listed(Yr hr mn) /�/l� � ® ELECTRI , ' ` Suprv. Electrician signature,required: 4 Subtotal: III,PO Print name: V taci CA i� Date: y-/5/, I 0 Plan Review Required(25%of permit fee): 6.---------- State surcharge(12%of permit fee): Authorized signature: t /// TOTAL PERMiT FEE: This permtit application expires if a permit is not obtained within 180 2 �G� Print name: tVr rllL-�t{. Date:-It a/a( days after it has been accepted as complete. I * Number of inspections allowed per permit) 1\Budding'Permits\6LC_PermirApp_Et.R_ERF.doe Rev 06/17/2015 440-46I5T(I I/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONIJ . *iligN,E Ucwnplinn Qty. Eat Total j Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25 01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 65.25/hr 1 charged at an hourly(I hr min) Inspections for which no fee is 90.00/hr specifically listed('/hr mini `' t:.3 WORK ONLY: Kr ELECTRICAL PERMIT FEES Subtotal(Enter on Page 1): Fee for each commercial system: $75.00 * Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1\Building\Permits\ELC_PermitApp_ELR_ERE_doc Rev 06/172015 Plumbing Permit Application Building Fixtures RECEIVE I FOR OFFICE USE ONLY Received City Tigard APR 0 5 2D21 Permit N r(S j ZOu 60 91 13125 SW Hall Blvd.,Tigard,OR 97223 plan Reviewy Phone: 503.718.2439 Fax: 503.598.1960 Plan : S Date/B Other Permit No.: Inspection Line: 503.639.4175 CITY OF TIGARD Y T[CARD Date Ready/By 1;445 RI See Page 2 for Internet www Tigard-orgov 1 I i,NotifiedlMethod i I,� Supplemental Information '. TYPE OF WORK .AlittFEE* SCHEDULE For special information use checklist. ❑New construction Demolition Description I Qty. I ha. rota! ►" Addition/alteration/replacement D Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) - F Y OF CONSTRUCTION SFR(1)bath 312.70 ►, 1-and 2-family dwelling ❑Commercial/industrial SFR(2)bath 437.78 SFR(3)bath 500.32 ❑Accessory building ❑Multi-family Each additional bath/kitchen 25.02 D Master builder ❑Other: Fire sprinkler(_sq.ft.) Page 2 JOB SITE LNFORMATION AND LOCATION Site utilities: . Job site address: l b $- S(,f � 2 a (�Jtu / Catch basin or area drain 18.76 "go qK / Drywell,leach line,or trench drain 18.76 City/State/ZIP: "i t Q I-d 6� ci 7 ad 3 � p Footing drain(no.linear ft.. ) Page 2 Suite/bldg./apt.no.: Project name: t�l,,uaP r- Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 Rain drain connector 18.76 Sanitary sewer(no.linear ft.:, ) Page 2 Storm sewer(no.linear ft.:_) Page 2 Water service(no.linear ft.: ) Page 2 Subdivision: I Lot no.: Fixture or item: Tax map/parcel no.: Backflow preventer 31.27 I i]1 $ DESCRIPTION OF WORK Backwater valve 12.51 ., '�' Clothes washer 25.02 Krf Ul PC M c:LA � I ItlOt S(J( i (7l✓ Dishwasher I 25.02 as-.o a Drinking fountain 25.02 Ejectors/sump 25.02 PROPERTYLOWNER I ElI' ,24 TENAN ,, Expansion tank 12.51 Fixture/sewer cap 25.02 Name: t wt.t (3ot,t r Floor drain/floor sink/hub 25.02 Address: (D Li S 3 ,c(_./ a via K e ct, 1+./0Y Garbage disposal I 25.02 ,),-1-, if 1 City/State/Z1P: i lq rd , 012_ i?as 3 Hose bib 25.02 Phone:( ) Fax:( ) Ice maker I 12.51 p „VI APPLICANT 0 CONTACT PERSON Interceptor/grease trap 25.02 Business name: N -I-'A d L- "� Hr J, Medical gas(value:$ ) Page 2 �r a ��, r�� ati U � yn �"• Primer 12.51 Contact name: g r iv s.. P.� l Roof drain(commercial) 12.51 Address: 3,6066SL,/ Ca!/pe0-, 4 Sink/basin/lavatory I 25.02 aJ,Oa City/State/ZIP: SInP r 4Jo e oft f(Q 2_ Q'2 <(0 Solar units(potable water) 62.54 Phone: Fax:: Tub/shower/shower pan 12.51 (ram> ) a�� �a�� ( ) / / Urinal 25.02 E-mail: brig✓110474Q.VlorTk/e/1441nl/AclCet-fettt,ld.rotr-t Water closet 25.02 CONTRACTOR f Water heater 37.52 Business name: ,fa -Wet Ls Ph(WLO(.-t J Water piping/DWV 56.29 Address: 7 7,3 Y SL C I i r U,c D f Other: 25.02 City/State/ZIP: eRu-er'Int'l O . 9?Oo Subtotal ➢2,5'D �6 CC p� Minimum permit fee: $72.50 Phone:(S 03) 67 6( Fax:( ) Plan review (25%of permit fee) CCB Lic.: Z 9ke(y J/j t Plumbing Lic.no.:a p-/t('p State surcharge(12%of permit fee) Authorized signature: /\ ) TOTAL PERMIT FEE / / This permit application expires if a permit is not obtained within 180 days Print name: t,t'� n Date: I{/ a[ a f after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Pernrits\PLMU-PermitApp.doe 10/01/09 440-46t6T(10/02/COM/WEB) Plumbing Permit Application - City of Tigard Page 2 - Supplemental Information Fee Schedule: Residential Fire Sur r ression S stems: Site Utilities Qty. Fee teal Total k rv.. uravurouu Footing drain-I"100' 50.03 0 to 2,000 $121.90 Footing drain-each additional 100' 37.52 2,001 to 3,600 $169.69 3,601 to 7,200 $233.20 Sewer-1st 100' 62.54 7,201 and greater $327.54 Sewer-each additional 100' 37.52 Water Service-1st 100' 62.54 Medical Gas Systems: Water Service-each additional 100' 37.52 Valuation: Permit Fee: Storm&Rain Drain-1st 100' 62.54 $1.00 to$5,000.00 Minimum fee$72.50 Storm&Rain Drain-each additional 100' 37.52 $5,001.00 to$10,000.00 $72.50 for the first S5,000.00 and$1.52 for Other Inspections or Fees Qty. Fee(ea) Total each additional$100.00 or fraction thereof,to and including$10,000.00. Inspection of existing plumbing or for $10,001.00 to$25,000.00 $148.50 for the first$10,000.00 and$1.54 for which no fee is specifically indicated 90.00/hr each additional$100.00 or fraction thereof,to (minimum charge-1/2 hour) and including$25,000.00. Inspections outside of normal business 90.00/hr $25,001.00 to$50,000.00 $379.50 for the first$25,000.00 and$1.45 for hours(minimum charge-2 hours) each additional$100.00 or fraction thereof,to Reinspection Fees 90.00/hr and including$50,000.00. Additional plan review for revisions 90.00/hr $50,001.00 and up $742.00 for the first$50,000.00 and$1.20 for (minimum charge-1/2 hour) each additional$100.00 or fraction thereof. Subtotal: Commercial Fixture Work: Are you capping,adding or replacing fixtures? If"yes", please indicate work performed by fixture. Failure to accurately report fixtures could result in increased sewer fees*. Plan Review f umbing Installations Quantity by Fixture Type Plan review is required for any of the following. Fixture Type for Replace/ Please check all that apply. Work Performed: Capped Added Relocate Baptistry/Font ❑ Any new commercial building with water service 2"and greater,except systems designed and stamped by licensed Bath: -Tub/Shower - -Jacuzzi/Whirlpool - engineer. Car Wash Each Stall ❑ New exterior plumbing site utilities for any complex structure Drive Thru as defined in OAR918-780-0040. Cuspidor/Water Aspirator ❑ Medical gas and vacuum systems for health care facilities. Dishwasher: Commercial El Any multipurpose fire sprinkler system. Domestic ❑ Any complex structure as defined in OAR918-780-0040. Drinking Fountain Eye Wash Submit 2 sets of plans with any of the above. Floor Drain/sink: -2" 3" Isometric or Riser Diagram ❑ Isometric or riser diagram is required for new buildings -Car Wash Drain that meet the qualifications above. Garbage -Domestic non-food - Disposal: -Domestic food related -Commercial food related -Industrial food related Ice Mach./Refrig.Drains Comments regarding fixture work: Oil Separator(Gas Station) -Shower. Vehicle Dump Station Shower: -Gang -Stall Sink: -Lay/Bar non-food related _ -Bradley -Com/Serv/Util food related -Service *Note: If the fixture work under this permit results in an Swimming Pool Filter increase of sewer EDUs,a sewer permit will be issued and Washer-Clothes fees assessed for the sewer increase must be paid before the Water Extractor Water Closet-Toilet plumbing permit can be issued. Urinal Other Fixtures: L\Building\Permits\PLMF_PermitApp.doc 08/04/2011 2 Lina Smith From: Lina Smith Sent: Wednesday, April 7, 2021 3:27 PM To: brianpettit@northlanddesignandbuild.com Cc: Agnes Lindor; Nikki Tuason; #Building Permit Technicians Subject: Bauer Remodel - 10483 SW Bonanza Way Hi Brian, I started the Planning/Zoning check for this building permit.Your plans show that the new window on the north side of the house (dining room side) will be shorter than the existing window. Please submit 3 copies of an elevation drawing that shows you'll still maintain at least 12%window coverage on the northern house façade: http://qcode.us/codes/tigard/view.php?topic=18-18 200-18 290-18 290 040&frames=on Please drop of the 3 copies in the Permit Center lobby anytime from Mondays to Thursdays, 8 a.m. to 5 p.m. Make sure to include a transmittal letter: https://www.tigard-or.gov/document center/Building/Transmitta lLetter.pdf Thank you, Lina Smith Assistant Planner City of Tigard I Community Development 13125 SW Hall Blvd.Tigard,OR 97223 E-mail: LinaCS@tigard-or.gov 1 Nikki Tuason From: Nikki Tuason Sent: Monday, April 19, 2021 12:25 PM To: brianpettit@northlanddesignandbuild.com Cc: #Building Permit Technicians Subject: 10483 Bonanza Way Attachments: WaterMeters_070119_New.pdf Hi Brian, I signed off on the planning review permit for the kitchen remodel at 10483 SW Bonanza Way, the windows on the North facing wall in the dining area will remain unchanged and the plans have been marked to reflect this as discussed to maintain the street facing facade 12%window requirement. Please expect an email shortly from the building department requesting for permit fee payment. The following item/s will be required prior to the issuance of the building permit. Please be advised that we may not issue the building permit until the following items are received: • If you are adding to the number of existing fixtures, please complete the Water Meter Fixture Unit Worksheet (attached to this email). Thank you, Nikki Nikki Tuason Assistant Planner City of Tigard I Community Development 13125 SW Hall Blvd. Tigard, OR 97223 nikkit@tigard-orgov 1 CITY OF TIGARD BUILDING PERMIT 111 1 COMMUNITY DEVELOPMENT Permit#: BUP2021-00083 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/3/2D21 T f t:A,li t-3 9 Parcel: 2S101 BB01500 Jurisdiction: Tigard Site address: 12244 SW GARDEN PL Project: Mannahouse Church Subdivision: CROW PARK 217 Lot: 3 Project Description: Alteration to existing interior partition walls.New platform 8 AV booth Contractor: EMANUEL CONSTRUCTION LLC Owner: BKM PARK BC 252 LLC BY SLK GLOBAL SOLUTIONS AMERICA 2727 LBJ FREEWAY STE 806 DALLAS,TX 75234 PHONE: PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 04/27/2021 $377.90 Demolition Occupancy Grp: A-2 Occupancy Load: 12%State Surcharge-Building 04/27/2021 $45.35 Dwelling Units: 0 Plan Review 04/15/2021 $245.64 Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 04/27/2021 $103.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 04/27/2021 $151.16 Value: $201000 Info Process/Archiving-Lg$2.00(over 04/27/2021 $10.00 11x17) Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $933.05 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090, You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: vouy vA.vU'DP We..ve Permittee Signature: Owl lic,�.tLo-vt pp Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. I CITY OF TIGARD BUILDING PERMIT . 11 ': * COMMUNITY DEVELOPMENT Permit#: BUP2021-00075 Date Issued: 5/27/2021 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S102CB02700 Jurisdiction: Tigard Site address: 13050 SW PACIFIC HWY Project: Sanchez Taqueria Subdivision: None Lot: None Project Description: New awning for front entrance Contractor: OWNER Owner: WALTER,ANGELA D GUADALUPE SANCHEZ JERONIMO 2863 RIVERWALK LP 13050 SW PACIFIC HWY EUGENE, OR 97401 TIGARD, OR 97223 PHONE: PHONE: 503-887-5557 FAX: FEES Specifics: Date Amount Description Type of Use: COM Permit Fee-Additions,Alterations, 05/24/2021 $60.05 Class of Work: ALT Type of Const: VB Demolition Occupancy Grp: B Occupancy Load: 0 12%State Surcharge-Building 05/24/2021 $7.21 Dwelling Units: 0 Plan Review 04/01/2021 $39.03 Stories: 0 Height: 0 ft Info Process/Archiving-Sm$0.50(up to 05/24/2021 $1.50 Bedrooms: 0 Bathrooms: 0 11x17) Value: $670 Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $107.79 Required Items and Reports(Conditions) Required: Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503 232.1987 or 1.800.332.2344. Issued By: Z.....„/...e,..)07, 557----14rmittee Signature: Set .f9/Cif Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT 1111 ■ COMMUNITY DEVELOPMENT Permit#: BUP2021-00109 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/26/2021 T f G A R O 9 Parcel: 2S112DD01600 Jurisdiction: Tigard Site address: 15495 SW SEQUOIA PKWY 150 Project: Steward Partners Subdivision: PACIFIC CORPORATE CENTER Lot: 4 Project Description: Remodel work to 3960 sf of office space.Work includes selected demo of existing nonstructural walls, nonstructural drywall/metal studs walls,suspended ceilings,doors/frames,painting,electrical distribution and lighting. Contractor: PACIFIC REALTY ASSOCIATES LP Owner: PACIFIC REALTY ASSOCIATES 15350 SW SEQUOIA PKWY#300 ATTN: N PIVEN PORTLAND, OR 97224 15350 SW SEQUOIA PKWY#300 PORTLAND, OR 97224 PHONE: 503-624-6300 PHONE: FAX: 503-624-7755 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: IIB Permit Fee-Additions,Alterations, 05/24/2021 $564.15 Demolition Occupancy Grp: B Occupancy Load: 40 12%State Surcharge-Building 05/24/2021 $67.70 Dwelling Units: 0 Plan Review 05/06/2021 $366.70 Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 05/24/2021 $103.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 05/24/2021 $225.66 Value: $35,000 Info Process/Archiving-Lg$2.00(over 05/24/2021 $8.00 11)(17) Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $1,335.21 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code. State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332,2344. Issued By: How,Va.vv'De wege Permittee Signature: 0 Applica t,ar1. Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT • - COMMUNITY DEVELOPMENT II Permit#: MST2021-00082 T l G A R.f7 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/27/2021 Parcel: 1S135CC05900 Jurisdiction: Tigard Site address: 11824 SW PENNY LN Subdivision: BURT'S LANDING Lot: 11 Project: Burt's Landing, Lot 11 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 5 First: 1246 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 26 Bathrooms: 3 Second: 1682 sf Garage: 606 sf Front: 20 Smoke Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Yes Total: 2928 sf Value: $387,832.68 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100Catch Basins: 0 Bckflw Prevntr: 1 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 5 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 6 201-400 amp: 0 201-400 amp: 0 WIG Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VP R-3 2928 Owner: Contractor: WESTWOOD HOMES LLC WESTWOOD HOMES LLC Required Items and Reports(Conditions) 12700 NW CORNELL RD 12700 NW CORNELL RD 1 Ersn Cntrl 503-639-4175 PORTLAND,OR 97229 PORTLAND,OR 97229 PHONE: PHONE: 503-330-2215 FAX: 503-342-2403 Total Fees: $40,464.80 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. f Issued By: V ) I ' V 'Delwee Permittee Signature: 0wAPP 'aan Call 503.639A175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT 'I" s COMMUNITY DEVELOPMENT Permit#: MST2021-00187 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/27/2021 Parcel: 2S109AC08400 Jurisdiction: Tigard Site address: 13063 SW FORAN HILLS CT Subdivision: None Lot: None Project: Foran Hills, Lot 5 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 1122 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 24 Bathrooms: 3 Second: 1578 sf Garage: 505 sf Front: 15 Smoke Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Yes Total: 2700 sf Value: $358,526.94 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Gr oup:yrou p: Square Feet: NEW SF VB R-3 2700 Owner: Contractor: STONE BRIDGE HOMES NW LLC STONE BRIDGE HOMES NW LLC Required Items and Reports(Conditions) 4230 GALE WOOD ST STE 100 4230 GALE WOOD STREET#100 1 Ersn Cntrl 503-639-4175 LAKE OSWEGO,OR 97035 LAKE OSWEGO,OR 97035 PHONE: PHONE: 503-387-7577 FAX: 503-387-7615 Total Fees: $39,190.42 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: }(o7,LyVIvniDebUece Permittee Signature: O VI/Appll:Cat"wn Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the Job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT IIa. ' COMMUNITY DEVELOPMENT Permit#: MST2021-00200 TT G A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/26/2021 Parcel: 1 S 125DA11900 Jurisdiction: Tigard Site address: 6570 SW ALFRED ST Subdivision: 1997-078 PARTITION PLAT Lot: 3 Project: Black Project Description: Repair of house, roof, walls,floor and sheathing cause by fallen tree. BUILDING • Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $170,000.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywall-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel TVDBS Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furna=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System. N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VS R-3 0 Owner: Contractor: BLACK,JESSE W&KAREN K BRIGHT CONSTRUCTION LLC Required Items and Reports(Conditions) 6570 SW ALFRED ST 1248 SPRUCE ST TIGARD,OR 97223 LAKE OSWEGO,OR 97034 PHONE: PHONE: 971-678-6618 FAX: Total Fees: $2,836.89 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire it work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: ftolIN Vain/De,We4ye Permittee Signature: O n'Appli.c 7.t-O vt Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the Job site at the time of each inspection. • lig CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2021-00059 Date Issued: 05/25/2021 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S106AC05100 Jurisdiction: Tigard Site address: 17040 SW LEMONGRASS LN Subdivision: RIVER TERRACE EAST 3 Lot: 247 Project: River Terrace Northeast No. 3, Lot 23 Project Description: New attached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 2 First: 235 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 38 Bathrooms: 4 Second: 594 at Garage: 298 sf Front: 10 Smoke Yes Dwelling Units: 1 Third: 584 sf Right: 0 Detectors: Total: 1413 sf Value: $188,448.30 Rear: 0 PLUMBING Sinks: 2 Water Closets: 4 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain 0 Storm Sewer: 100 • Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: Catch Basins: 0 • Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 1 Backwater Value: 1 Other Fixtures: 0 Drywall-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add l 500 sf: 2 201-400 amp: 0 201-400 amp: 0 W/O Svc./Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: NI HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Ecompasing: Other: N Other Description: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1413 Owner: Contractor: WLLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 2 Fire Rated Conditions PHONE: PHONE: 360-695-7700 FAX: Total Fees: $26,925.83 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: }folly Va4111)e'We4ge Permittee Signature: 0►tiAppLi l-O-'t Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the Job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT fii s ' COMMUNITY DEVELOPMENT Permit#: MST2021-00058 Date Issued: 05/25/2021 T1 G AR D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S106AC05000 Jurisdiction: Tigard Site address: 17054 SW LEMONGRASS LN Subdivision: RIVER TERRACE EAST 3 Lot: 246 Project: River Terrace Northeast No. 3, Lot 22 Project Description: New attached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 3 First: 68 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 36 Bathrooms: 3 Second: 670 sf Garage: 530 sf Front: 10 Smoke Yes Dwelling Units: 1 Third: 1033 sf Right: 0 Detectors: Total: 1771 sf Value: $243,834.22 Rear: 0 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain 0 Storm Sewer: 100 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: Catch Basins: 0 Bckflw Prevntr. 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 1 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvciFeeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mid Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1771 Owner: Contractor: WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 2 Fire Rated Conditions PHONE: PHONE: 360-695-7700 FAX: Total Fees: $28,508.77 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Roily De,Wege Permlttee Signature: O► Appkt Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2021-00057 T[GAR I: 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/25/2021 Parcel: 2S106AC04900 Jurisdiction: Tigard Site address: 17070 SW LEMONGRASS LN Subdivision: RIVER TERRACE EAST 3 Lot: 245 Project: River Terrace Northeast No.3, Lot 21 Project Description: New attached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 2 First: 317 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 36 Bathrooms: 4 Second: 631 sf Garage: 246 sf Front: 10 Smoke Dwelling Units: 1 Third: 982 sf Right: 3 Detectors: Yes Total: 1930 sf Value: $249,733.72 Rear: 0 PLUMBING Sinks: 2 Water Closets: 4 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bcktw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 1 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: Other Fixture Units: MECHANICAL Fuel TvDes Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents; 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 st or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio i,Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1930 Owner: Contractor: WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 2 Fire Rated Conditions PHONE: PHONE: 360-695-7700 FAX: Total Fees: $29,085.88 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. i(oUy Vary De/WeSe owAppl,,ca ion Issued By: Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept In a conspicuous place on the Job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2021-00143 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/25/2021 Parcel: 2S111 BA02500 Jurisdiction: Tigard Site address: 14470 SW 100TH AVE Subdivision: TIGARDVILLE HEIGHTS Lot: 30 Project: White Project Description: Master bedroom&bathroom relocation (addition) Remove walls in living area&add load bearing beams BUILDING Floor Areas Required Setbacks Required Stories: 1 Bedrooms: 0 First: 496 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 13 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 20 Smoke Dwelling Units: 0 Third: 0 sf Right: 5 Detectors: Yes Total: 496 sf Value: $60,740.16 Rear: 15 PLUMBING Sinks: 0 Water Closets: 1 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 4 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 3 Garbage Disp: 0 Water Heaters: 1 Water Lines: 0 Catch Basins: 0 Bcktlw Prevntr-. 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Tyres Air Conditioning: Y Vent Fans: 2 Clothes Dryers: 0 Natural Gas Heat Pump: N Hoods: 1 Other Units: 1 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL _Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less, 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 3 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 496 Owner: Contractor: WHITE.SHANA L&WILLIAM A Required Items and Reports(Conditions) 14470 SW 100TH AVE Ql vrl� 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97224 PHONE: PHONE: FAX: Total Fees: $3,727.94 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: }{D IN VCt41,Ve'Wee Permittee Signature: 0 in/Ap7)UGatloft Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT 111 1. . COMMUNITY DEVELOPMENT Permit#: MST2021-00146 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/2412021 T[G A R I7 Parcel: 2S111 BA09000 Jurisdiction: Tigard Site address: 9515 SW ELROSE ST Subdivision: 1994-019 PARTITION PLAT Lot: 2 Project: Ellis Project Description: Voluntary underpinning using 9 push piers BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $20,485.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker. 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fumy=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 WI Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm. N Vaccuum System: N Garage Opener N All Ecompasing: N Other: N Other Description: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: ELLIS,TRINITY&HOA TERRAFIRMA FOUNDATION SYSTEMS INC Required Items and Reports(Conditions) 9515 SW ELROSE ST 13110 SW WALL STREET 1 Special Inspection-Pilings, TIGARD,OR 97224 TIGARD,OR 97223 Drilled Piers ans Caissons PHONE: PHONE: 971-205-5223 FAX: 503-491-5301 Total Fees: $721.80 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1,800,332.2344. Issued By: H0Y VafvDPAWei e Permlttee Signature: O W Applt ca t a t Call 503.639.4175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept In a conspicuous place on the Job site until completion of the project. Approved plans are required on the Job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT 2 ' COMMUNITY DEVELOPMENT Permit#: MST2021-00173 Date Issued: 05/24/2021 T I G A R t7 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S102DCO2001 Jurisdiction: Tigard Site address: 9400 SW EDGEWOOD ST Subdivision: EDGEWOOD Lot: 18 Project: Nemaric Project Description: Interior remodel: replacement finishes and fixtures. Existing roof to be removed to vault ceilings, minor reflow of partition walls."Exempt"deck to be added on to rear of house. Trade permits to BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First:. 0 sf Basement. 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right 0 Detectors: Total: 0 sf Value: $30,000.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Tubs/Showers: 0: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temo Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea addl 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-800 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF 0 Owner: Contractor: NEMARIC,JELENA SINCLAIR CONSTRUCTION Required Items and Reports(Conditions) MILJANIC,FRANE 470 2ND STREET SUITE A 9400 SW EDGEWOOD ST LAKE OSWEGO,OR 97034 TIGARD,OR 97223 PHONE: PHONE: 971-512-0300 FAX: Total Fees: $1,057.02 This permit is issued subject to the regulations contained in the Tigard Municipal Code. State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: HoU.yVcuv'De'Wege PermltteeSignature: 0wApPUt"� Call 503.639.4175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT 1111 la- n COMMUNITY DEVELOPMENT Permit#: MST2021-00169 .TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/24/2021 Parcel: 1S135CD02800 Jurisdiction: Tigard Site address: 9550 SW LEWIS LN Subdivision: BOETCHERS ADDITION TO GREEN BURG I Lot: 6 Project: Nicholson Project Description: Rooftop Solar PV BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $10,600.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea addl 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Horne/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: NI Vaccuum System: N Garage Opener: N All Other: Y Other Description: Roof Top Solar PV System 10 KVA Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: NICHOLSON,JADE M&ERIK W AAND R SOLAR CORP Required Items and Reports(Conditions) 9550 SW LEWIS LN 1887 SW MILPORT RD TIGARD,OR 97223 MILWAUKIE,OR 97222 PHONE: PHONE: 503-939-7663 FAX: Total Fees: $354.69 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through SOAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. H Issued By: "'7^'Y Van/De,WPge Permittee Signature: 0YVf4ppUcca o-Vt Call 503.639A175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the Job site at the time of each Inspection. CITY OF TIGARD MASTER PERMIT s COMMUNITY DEVELOPMENT Permit: MST2021-00062 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/25/2021 Parcel: 2S106AC05300 Jurisdiction: Tigard Site address: 17022 SW LEMONGRASS LN Subdivision: RIVER TERRACE EAST 3 Lot: 249 Project: River Terrace Northeast No.3, Lot 25 Project Description: New attached dwelling BUILDING Floor Areas Reauired Setbacks Required Stories: 3 Bedrooms: 3 First: 335 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 36 Bathrooms: 4 Second: 658 sf Garage: 246 sf Front: 10 Smoke Dwelling Units: 1 Third: 998 sf Right: 0 Detectors: Yes Total: 1991 sf Value: $257,203.78 Rear: 0 PLUMBING Sinks: 2 Water Closets: 4 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 1 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-10o0v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Yasin : Other: N Other Description: Ecom P 9� BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1991 Owner: Contractor: Required Items and Reports(Conditions) 1 Ersn Cntrl 503-639-4175 2 Fire Rated Conditions PHONE: PHONE: FAX: Total Fees: $29,156.42 • This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: }{ply V(m/De'We.*e Permittee signature: O►t'AppUCatwn Call 503.639.4176 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the Job site until completion of the project. Approved plans are required on the job site at the time of each Inspection. CITY OF TIGARD MASTER PERMIT 111 111 COMMUNITY DEVELOPMENT Permit#: MST2021-00061 Date Issued: 05/25/2021 T I G A R P 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 2S106AC05200 Jurisdiction: Tigard Site address: 17034 SW LEMONGRASS LN Subdivision: RIVER TERRACE EAST 3 Lot: 248 Project: River Terrace Northeast No. 3, Lot 24 Project Description: New attached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 3 First: 68 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 36 Bathrooms: 3 Second: 670 sf Garage: 530 sf Front: 10 Smoke Dwelling Units: 1 Third: 1033 sf Right: 0 Detectors: Yes Total: 1771 sf Value: $243,834.22 Rear: 0 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 1 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecornpasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1771 Owner: Contractor: WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 2 Fire Rated Conditions PHONE: PHONE: 360-695-7700 FAX: Total Fees: $28,508.77 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Holly Vra vvDe,Wege Issued By: Permittee Signature: (7VLAr1pU�r�i;n�L Call 503.939A175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job she at the time of each Inspection. CITY OF TIGARD BUILDING PERMIT ■s COMMUNITY DEVELOPMENT Permit#: BUP2021-00 1 1 0 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/20/2021 T I i A R. L. g Parcel: 2S102AC01701 Jurisdiction: Tigard Site address: 12700 SW PACIFIC HWY Project: Pipeline Plumbing Subdivision: None Lot: None Project Description: Enlarge shop size and raise the roof Contractor: BAILEY CONTRACTING LLC Owner: FARENHEIGHT LLC 333 S STATE ST SUITE V 277 1885 CREST DR LAKE OSWEGO, OR 97034 LAKE OSWEGO,OR 97034 PHONE: 971-235-5532 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 05/20/2021 $932.76 Demolition Occupancy Grp: B Occupancy Load: 49 12%State Surcharge-Building 05/20/2021 $111.93 Dwelling Units: 0 Plan Review 05/05/2021 $596.51 Stories: 1 Height: 0 ft DC Provision Review,COM TI-Ping 05/20/2021 $257.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 05/20/2021 $373.10 Value: $76,900 Info Process/Archiving-Sm$0.50(up to 05/20/2021 $17.50 11x17) Tigard CET-Non-Residential-Admin 05/20/2021 $30.76 Floor Areas: Tigard CET-Non-Residential-AH 05/20/2021 $738.24 Total Area: 384 Tig-Tual School CET-Non-Residential 05/20/2021 $264.96 Plan Review 05/20/2021 $9.78 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $3,332.54 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code. State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You ma obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: iC Permittee Signature: ba-71a� /t Call 503.639.4175 by 7:00 a.m.for the next available inspection date. r/// !'r v"C This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT COMMUNITY DEVELOPMENT Permit A: BUP2021-00106 Date Issued: 5/20/2021 TI G A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S135AB01003 Jurisdiction: Tigard Site address: 10300 SW GREENBURG RD 120 Project: Spec Space Subdivision: METZGER, TOWN OF Lot: 9 Project Description: Landlord work prior to TI: Demolition and new finishes. Contractor: RUSSELL CONSTRUCTION INC Owner: LINCOLN CENTER LLC 20915 SW 105TH AVE BY SHORENSTEIN PROPERTIES LLC TUALATIN, OR 97062 235 MONTGOMERY ST, 16TH FLOOR SAN FRANCISCO, CA 94104 PHONE: 503-692-9002 PHONE: FAX: 503-692-9008 FEES Specifics: Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: jg Permit Fee-Additions,Alterations, 05/19/2021 $164.96 Demolition Occupancy Grp: B Occupancy Load: 15 12%State Surcharge-Building 05/19/2021 $19.80 Dwelling Units: 0 Plan Review 05/05/2021 $107.22 Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 05/19/2021 $103.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 05/19/2021 $65.98 Value: $6,000 Info Process/Archiving-Lg$2.00(over 05/19/2021 $4.00 11x17) Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $464.96 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-009 You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT 7111 COMMUNITY DEVELOPMENT Permit#: BUP2021-00107 T I( A R n 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/20/2021 Parcel: 1 S 135AB01003 Jurisdiction: Tigard Site address: 10300 SW GREENBURG RD 200 Project: Spec Space Subdivision: METZGER,TOWN OF Lot: 9 Project Description: Landlord work prior to TI: Demolition and new finishes Contractor: RUSSELL CONSTRUCTION INC Owner: LINCOLN CENTER LLC 20915 SW 105TH AVE BY SHORENSTEIN PROPERTIES LLC TUALATIN, OR 97062 235 MONTGOMERY ST, 16TH FLOOR SAN FRANCISCO, CA 94104 PHONE: 503-692-9002 PHONE: FAX: 503-692-9008 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: IB Permit Fee-Additions,Alterations, 05/19/2021 $164.96 Demolition Occupancy Grp: B Occupancy Load: 30 12%State Surcharge-Building 05/19/2021 $19.80 Dwelling Units: 0 Plan Review 05/05/2021 $107.22 Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 05/19/2021 $103.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 05/19/2021 $65.98 Value: $6,000 Info Process/Archiving-Lg$2.00(over 05/19/2021 $4.00 11x17) Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $464.96 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. Yo may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Permittee Signature: A(�(//� � 6///� Call 503.639.4175 by 7:00 a.m.for the next available inspection date. / This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. • CITY OF TIGARD BUILDING PERMIT R! COMMUNITY DEVELOPMENT BUILDING MST2021-00177 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/19/2021 TIGARD Parcel: 1S136AA10800 Jurisdiction: Tigard Site address: 10186 SW 69TH AVE Project: CALDWELL Subdivision: OAK STREET ESTATES Lot: 3 Project Description: A new 312 sq.ft.in-ground swimming pool with 976 sq.ft.of impervious surface. Contractor: OWNER Owner: CALDWELL,TRICIA&RYAN MILLER, BRIDGET 10186 SW 69TH AVE TIGARD, OR 97223 • PHONE: PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: SF Class of Work: OTR Type of Const: VB DC Provision Review,SF-Ping 05/19/2021 $103.00 Occupancy Grp: R-3 Occupancy Load: Info Process/Archiving-Sm$0.50(up to 05/19/2021 $8.00 11x17) Dwelling Units: 0 Other,Heating/Cooling 05/19/2021 $23.32 Stories: 0 Height: 0 ft Fuel Piping 05/19/2021 $14.15 Bedrooms: 0 Bathrooms: 0 Erosion Control w/Development 05/19/2021 $107.60 Value: $50,000 12%State Surcharge-Mechanical 05/19/2021 $10.80 (manual) Minimum Fee Adjustment-Mechanical 05/19/2021 $52.53 Floor Areas: Ejectors/Sump 05/19/2021 $50.04 12%State Surcharge-Plumbing 05/19/2021 $8.70 Total Area: (manual) Accessory Struct: 0 Minimum Fee Adjustment-Plumbing 05/19/2021 $22.46 Basement: Carport: 0 Covered Porch: 0 Deck: Garage: Mezzanine: Total $400.60 Required: Required Items and Reports(Conditions) 1 Ersn Cntrl 503-639-4175 Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Rermittee Signature: 47g ' 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the Job site until completion of the project. Approved plans are required on the Job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT COMMUNITY DEVELOPMENT Permit#: BUP202 1-001 1 3 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/19/2021 Parcel: 2S112DD00700 Jurisdiction: Tigard Site address: 15750 SW UPPER BOONES FERRY RD Project: PacTrust Subdivision: None Lot: None Project Description: Voluntary seismic strengthening of the wall anchorage systems to reduce the potential structural damage in an earthquake.Multiple addresses included: 15750, 15770,15780 and 15786 Upper Boones Ferry Rd. Contractor: MARVIN AND SONS CONSTRUCTION INC Owner: PACIFIC REALTY ASSOCIATES 8560 SE BONNIE JEAN WAY ATTN: N PIVEN CLACKAMAS,OR 97015 15350 SE SEQUOIA PKWY#300 PORTLAND, OR 97224 PHONE: 503-329-2826 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 05/18/2021 $804.75 Demolition Occupancy Grp: B Occupancy Load: 299 12%State Surcharge-Building 05/18/2021 $96.57 Dwelling Units: 0 Plan Review 05/10/2021 $523.09 Stories: 0 Height: 0 ft Info Process/Archiving-Lg$2.00(over 05/18/2021 $6.00 Bedrooms: 0 Bathrooms: 0 11x17) Value: $60,000 Info Process/Archiving-Sm$0.50(up to 05/18/2021 $12.00 11x17) Tigard CET-Non-Residential-Admin 05/18/2021 $24.00 Floor Areas: Tigard CET-Non-Residential-AH 05/18/2021 $576.00 Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $2.042.41 Required: Required Items and Reports(Conditions) 1 Special Inspection(see plans) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Permittee Signature: ifoilvVam De�Wege trJw,4 Li_critilrrn rr Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT 111 COMMUNITY DEVELOPMENT Permit#: BUP2021-00105 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/19/2021 Parcel: 2S112DA01400 Jurisdiction: Tigard Site address: 15350 SW SEQUOIA PKWY 320 Project: Riverside Homes Subdivision: 1996-048 PARTITION PLAT Lot: 2 Project Description: Remodel work to 1,922 usable sf/2,189 rentable sf of existing office space.Work includes selected demo of existing nonstructural walls, nonstructural drywall/medal studs wall, doors/frames,painting,electrical distribution and lighting Contractor: PACIFIC REALTY ASSOCIATES LP Owner: PACIFIC REALTY ASSOCIATES 15350 SW SEQUOIA PKWY#300 ATTN: N PIVEN PORTLAND, OR 97224 15350 SW SEQUOIA PKWY#300 PORTLAND, OR 97224 PHONE: 503-624-6300 PHONE: FAX: 503-624-7755 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: IIB Permit Fee-Additions,Alterations, 05/18/2021 $487.01 Demolition Occupancy Grp: B Occupancy Load: 13 12%State Surcharge-Building 05/18/2021 $58.44 Dwelling Units: 0 Plan Review 04/29/2021 $316.56 Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 05/18/2021 $103.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 05/18/2021 $194.80 Value: $28,000 Info Process/Archiving-Lg$2.00(over 05/18/2021 $6.00 11x17) Floor Areas: Total Area: 0 Accessory Struct: 0 • Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $1,165.81 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Holly V v Ve 1VeG.e Permittee Signature: Ovt IppUtlan c Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT COMMUNITY DEVELOPMENT Permit#: BUP2021-00104 Date Issued: 5/19/2021 • T f G A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S112DA01400 Jurisdiction: Tigard Site address: 15350 SW SEQUOIA PKWY 198 Project: CRA Subdivision: 1996-048 PARTITION PLAT Lot: 2 Project Description: Remodel 2,003 sf of existing office space.Work includes selected demo of existing nonstructural walls, nonstructural drywall/medal studs wall,doors/frames, painting,electrical distribution and lighting Contractor: VANOSDEL CONSTRUCTION LLC Owner: PACIFIC REALTY ASSOCIATES PO BOX 1057 ATTN: N PIVEN BATTLE GROUND,WA 98604 15350 SW SEQUOIA PKWY#300 PORTLAND, OR 97224 PHONE: 503-687-8636 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: B Permit Fee-Additions,Alterations, 05/18/2021 $487.01 Demolition Occupancy Grp: B Occupancy Load: 49 12%State Surcharge-Building 05/18/2021 $58.44 Dwelling Units: 0 Plan Review 04/29/2021 $316.56 Stories: 0 Height: 0 ft DC Provision Review,COM TI -Ping 05/18/2021 $103.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 05/18/2021 $194.80 Value: $27,800 Info Process/Archiving-Lg$2.00(over 05/18/2021 $6.00 11x17) Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 • Deck: 0 Garage: 0 Mezzanine: 0 Total $1,165.81 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: }foU,yVaw De„wage Permittee Signature: Ovv Opp Call 503.639.4175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT I COMMUNITY DEVELOPMENT Permit#: BUP2021-00112 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/13/2021 TIC.;1 R I? 9 Parcel: 2S112AC00600 Jurisdiction: Tigard Site address: 7440 SW BONITA RD Project: Portland Compressor Subdivision: None Lot: None Project Description: Install(4)wall signs Contractor: SECURITY SIGNS INC Owner: RL WILSON PROPERTIES LLC 2424 SE HOLGATE BLVD 9204 NW MCKENNA DR PORTLAND, OR 97202 PORTLAND, OR 97229 PHONE: 503-546-7114 PHONE: FAX: 503-230-1861 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 05/11/2021 $347.48 Demolition Occupancy Grp: U Occupancy Load: 0 12%State Surcharge-Building 05/11/2021 $41.70 Dwelling Units: 0 Plan Review 05/05/2021 $225.86 Stories: 0 Height: 0 ft Info Process/Archiving-Sm$0.50(up to 05/11/2021 $3.00 Bedrooms: 0 Bathrooms: 0 11x17) Value: $17,970 Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $618.04 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 • days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: O Vw1vDe,We4e Permittee Signature: OVl >Qppl%C Gltl o- t Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT 1111 I COMMUNITY DEVELOPMENT Permit#: BUP2021-00092 r l G A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/10/2021 Parcel: 2S 101 AB00801 Jurisdiction: Tigard Site address: 12320 SW 72ND AVE Project: Hampton Park Apartments-Clubhouse Subdivision: None Lot: None Project Description: Remove&replace siding,WRB&windows Contractor: LIFETIME EXTERIORS Owner: HAMPTON PARK APARTMENTS LLC 1100 NE 117TH AVENUE BY COOPER'S CHASE LLC VANCOUVER,WA 98684 3528 SW GALE AVE PORTLAND, OR 97239 PHONE: 971-801-4783 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 05/04/2021 $674.35 Demolition Occupancy Grp: A-2 Occupancy Load: 49 12%State Surcharge-Building 05/04/2021 $80.92 Dwelling Units: 0 Plan Review 04/19/2021 $438.33 Stories: 0 Height: 0 ft Info Process/Archiving-Sm$0.50(up to 05/04/2021 $37.50 Bedrooms: 0 Bathrooms: 0 11x17) Value: $45,000 Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $1,231.10 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION. Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503,232.1987 or 1.800.332.2344. Issued By: Hotly VafvDe,We,e Permittee Signature: O Ili Aph t Call 503.639.4175 by 7:00 a.m.for the next available inspection date. Y This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT COMMUNITY DEVELOPMENT Permit A: BUP2021-00093 and OR 97223 503.718.2439 13125 SW Hall Blvd.,Ti Date Issued: 5/10/2021 TIGARD9 Parcel: 2S101AB00801 Jurisdiction: Tigard Site address: 12366 SW 72ND AVE 211 Project: Hampton Park Apartments Subdivision: None Lot: None Project Description: Remove&replace siding,WRB,windows&guard railing. Contractor: LIFETIME EXTERIORS Owner: HAMPTON PARK APARTMENTS LLC 1100 NE 117TH AVENUE BY COOPER'S CHASE LLC VANCOUVER, WA 98684 3528 SW GALE AVE PORTLAND, OR 97239 PHONE: 971-801-4783 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 05/04/2021 $993.00 Demolition Occupancy Grp: R-2 Occupancy Load: 0 12%State Surcharge-Building 05/04/2021 $119.16 Dwelling Units: 0 Plan Review 04/19/2021 $645.45 Stories: 0 Height: 0 ft Info Process/Archiving-Sm$0.50(up to 05/04/2021 $37.50 Bedrooms: 0 Bathrooms: 0 11x17) Value: $85,000 Tigard CET-Non-Residential-Admin 05/04/2021 $34.00 Tigard CET-Non-Residential-AH 05/04/2021 $816.00 Plan Review-Fire Life Safety 05/04/2021 $397.20 Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $3,042.31 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 160 days of issuance, or if work is suspended far more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Permittee Signature: 4-7151 Mann,f)p.,ulp.je OwApplizatitrn Call 503.639.4176 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. f* CITY OF TIGARD BUILDING PERMIT COMMUNITY DEVELOPMENT Permit#: BUP2 02 1-00094 TIGARi7 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/10/2021 Parcel: 2S101AB00801 Jurisdiction: Tigard Site address: 12332 SW 72ND AVE Project: Hampton Park Apartments Subdivision: None Lot: None Project Description: Building 1:Remove and replace balcony guard railings. Contractor: LIFETIME EXTERIORS Owner: HAMPTON PARK APARTMENTS LLC 1100 NE 117TH AVENUE BY COOPER'S CHASE LLC VANCOUVER,WA 98684 3528 SW GALE AVE PORTLAND, OR 97239 PHONE: 971-801-4783 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: Permit Fee-Additions,Alterations, 05/03/2021 $164.96 Demolition Occupancy Grp: Occupancy Load: 12%State Surcharge-Building 05/03/2021 $19.80 Dwelling Units: 0 Plan Review 04/21/2021 $107.22 Stories: 0 Height: 0 ft Plan Review-Fire Life Safety 05/03/2021 $65.98 Bedrooms: 0 Bathrooms: 0 Info Process/Archiving-Sm$0.50(up to 05/03/2021 $6.00 Value: $6,000 11x17) Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $363.96 Required: Required items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes end all other applicable law. All work will be done in accordance with approved plans. This permit wit expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: .00124,VANIiDevele Permittee Signature: �YVAppUcatitrn Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT 11111 COMMUNITY DEVELOPMENT Permit#: BUP2021-00095 and OR 97223 503.718.2439 13125 SW Hall Blvd.,Ti Date Issued: 5/10/2021 TIGARD9 Parcel: 2S 101 AB00800 Jurisdiction: Tigard Site address: 12388 SW 72ND AVE Project: Hampton Park Apartments Subdivision: None Lot: None Project Description: Building 3: Remove and replace siding,WRB,windows and guard railing on balcony only. Contractor: LIFETIME EXTERIORS Owner: HAMPTON PARK APARTMENTS LLC 1100 NE 117TH AVENUE BY COOPER'S CHASE LLC VANCOUVER,WA 98684 3528 SW GALE AVE PORTLAND, OR 97239 PHONE: 971-801-4783 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 05/03/2021 $993.00 Demolition Occupancy Grp: R-2 Occupancy Load: 0 12%State Surcharge-Building 05/03/2021 $119.16 Dwelling Units: 0 Plan Review 04/21/2021 $645.45 Stories: 0 Height: 0 ft Into Process/Archiving-Sm$0.50(up to 05/03/2021 $37.50 Bedrooms: 0 Bathrooms: 0 11x17) Value: $85,000 Tigard CET-Non-Residential-Admin 05/03/2021 S34.00 Tigard CET-Non-Residential-AH 05/03/2021 $816.00 Plan Review-Fire Life Safety 05/03/2021 $397.20 Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $3,042.31 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 • This permit is issued subject to the regulations contained in the Tigard Municipal Code, Stale of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Houy Vail/ Wezle Permittee Signature: 0 In/App ban Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT s COMMUNITY DEVELOPMENT Permit#: BUP2021-00096 Date Issued: 5/10/2021 Tr G R n 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S101AB00800 Jurisdiction: Tigard Site address: 12400 SW 72ND AVE Project: Hampton Park Apartments Subdivision: None Lot: None Project Description: Building 4:Remove and replace siding,WRB,windows and guard railing on balcony only. Contractor: LIFETIME EXTERIORS Owner: HAMPTON PARK APARTMENTS LLC 1100 NE 117TH AVENUE BY COOPER'S CHASE LLC VANCOUVER,WA 98684 3528 SW GALE AVE PORTLAND, OR 97239 PHONE: 971-801-4783 PHONE: FAX: FEES Specifics: Description Date Amount Type of Use: COM Permit Fee-Additions,Alterations, 05/04/2021 $993.00 Class of Work: ALT Type of Const: VB Demolition Occupancy Grp: R-2 Occupancy Load: 0 12"/o State Surcharge-Building 05/04/2021 $119.16 Dwelling Units: 0 Plan Review 04/21/2021 $645.45 Stories: 0 Height: 0 ft Info Process/Archiving-Sm$0.50(up to 05/04/2021 $37.50 Bedrooms: 0 Bathrooms: 0 11x17) Value: $85,000 Tigard CET-Non-Residential-Admin 05/04/2021 $34.00 Tigard CET-Non-Residential-AH 05/04/2021 $816.00 Plan Review-Fire Life Safety 05/04/2021 $397.20 Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $3,042.31 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm. Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Nally Va.w De,We.e Permittee Signature: OWApp Li:ca-t[.on Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT I COMMUNITY DEVELOPMENT Permit#: BUP2021-00090 T t 1 A R 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/10/2021 Parcel: 2S 101 AD02800 Jurisdiction: Tigard Site address: 12665 SW 69TH AVE Project: US Investors Subdivision: WEST PORTLAND HEIGHTS Lot: 9 Project Description: Reconfiguring office space Contractor: ANDREW MOORE Owner: OMEGA ALPHA LLC 29965 S VIRGIL RD 760 NE 23RD AVE COLTON, OR 97017 CANBY, OR 97013 PHONE: 503-703-7570 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 05/05/2021 $955.35 Occupancy Grp: B Occupancy Load: 67 Demolition 12%State Surcharge-Building 05/05/2021 $114.64 Dwelling Units: 0 Plan Review Stories: 0 Height: 0 ft 04/15/2021 $620.98 DC Provision Review,COM TI-Ping 05/05/2021 8257.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 05/05/2021 382.14 Value: $80,000 $$14 Info Process/Archiving-Lg$2.00(over 05/05/2021 $14.0000 11x17) Tigard CET-Non-Residential-Admin 05/05/2021 $32.00 Floor Areas: Tigard CET-Non-Residential-AH 05/05/2021 $768.00 Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $3,144.11 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344_ Issued By: Permittee Signature: T-1o77y VoLo.9DPl weito D rvAppL%c a,tw-n Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the Job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT COMMUNITY DEVELOPMENT Permit#: BUP2021-00068 T I(s A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/10/2021 Parcel: 1 S 136C D02200 Jurisdiction: Tigard Site address: 7850 SW DARTMOUTH ST Project: Costco Wholesale Subdivision: PALMER ACRES Lot: 3 Project Description: 700 sq ft restroom remodel-work includes removal or replacement of all plumbing fixtures,finishes,accessories with related plumbing,electrical and mechanical work. Contractor: INTERSTATE CONSTRUCTION GROUP INC Owner: COSTCO WHOLESALE CORPORATION 437 29TH ST NE STE F PROPERTY TAX DEPT 111 PUYALLUP,WA 98372 999 LAKE DR ISSAQUAH, WA 98027 PHONE: 253-435-0949 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 05/10/2021 $2,193.15 Occupancy Grp: M Occupancy Load: Demolition 12%State Surcharge-Building 05/10/2021 $263.18 Dwelling Units: 0 Plan Review 03/23/2021 $1,425.55 Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 05/10/2021 $410.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 05/10/2021 $877.26 Value: $280,000 Info Process/Archiving-Lg$2.00(over 05/10/2021 $10.00 11x17) Metro CET 05/10/2021 $336.00 Floor Areas: Tigard CET-Non-Residential-Admin 05/10/2021 $112.00 Total Area: 0 Tigard CET-Non-Residential-AN 05/10/2021 $2,688.00 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $8,315.14 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1,800,332.2344. Issued By: Ho Vow De,We.�e Permittee Signature: OVl {{hh� can Call 503.639.4175 by 7:00 a.m.for the next available inspection date.f�r' This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT COMMUNITY DEVELOPMENT Permit#: BUP2021-00076 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/13/2021 TIGARD g Parcel: 1S136DB00201 Jurisdiction: Tigard Site address: 11565 SW PACIFIC HWY Project: Fred Meyer Subdivision: None Lot: None Project Description: Expand the(E)grocery pick up area inside the F.M.store.(E)walk-in cooler expanded&reach-in freezer relocated. Emp area only. New floral area built beside C.S desk.(2)add'I parking stalls will be converted to(2) grocery pick-up spaces. Contractor: CURT FAUS CORP Owner: FRED MEYER STORES INC 5775 JEAN RD STE 105 STORE#375 LAKE OSWEGO, OF 97035 1014 VINE ST PROPERTY TAX 7TH FLOOR CINCINNATI,OH 45202 PHONE: 503-699-1103 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 05/06/2021 $917.70 Demolition Occupancy Grp: M Occupancy Load: 12%State Surcharge-Building 05/06/2021 $110.12 Dwelling Units: 0 Plan Review 03/30/2021 $596.51 Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 05/06/2021 $257.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 05/06/2021 $367.08 Value: $75,000 Info Process/Archiving-Lg$2.00(over 05/06/2021 $26.00 11x17) Info Process/Archiving-Sm$0.50(up to 05/06/2021 $17.50 Floor Areas: 11x17) Tigard CET-Non-Residential-Admin 05/06/2021 $30.00 Total Area: 0 Tigard CET-Non-Residential-AH 05/06/2021 $720.00 Accessory Struct: 0 Additional Plan Review 05/06/2021 $45.00 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $3,086.91 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090, You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Roily VawDe,We Permittee Signature: e O w tlpplt;catwn Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT I. ' COMMUNITY DEVELOPMENT Permit#: MST2021-00176 _TIGARD13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/13/2021 Parcel: 2S112BC13500 Jurisdiction: Tigard Site address: 8036 SW LEISER LN Subdivision: LEISER PARK Lot: 4 Project: Miller Project Description: Rooftop Solar PV BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $11,832.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Tvoes Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstaves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 2 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other. Y Other Description: Roof Top Solar PV System 8.16 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr. Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: MILLER,MAX M JR&LORI J ION DEVELOPER LLC Required Items and Reports(Conditions) 8036 SW LEISER LN 3214 NORTH UNIVERSITY AVE TIGARD,OR 97224 503 PROVO,UT 84604 PHONE: PHONE: (888)781-7074 FAX: Total Fees: $424.92 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: }f oily Vavl.De,klecje Permittee Signature: Ow5Ipplfcat-Ley-pi Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. III CITY OF TIGARD MASTER PERMIT ii' ' COMMUNITY DEVELOPMENT Permit#: MST2 02 1-001 2 2 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/17/2021 T r i; II,I't 9 Parcel: 2S103AD06200 Jurisdiction: Tigard Site address: 12655 SW 111TH PL Subdivision: WILDERNESS Lot: 8 Project: Nielsen Project Description: Build new master&master bath onto existing home(+561 sq ft) BUILDING Floor Areas Required Setbacks Required Stories: 1 Bedrooms: 1 First: 561 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 13.75 Bathrooms: 1 Second: 0 sf Garage: 0 sf Front: 20 Smoke Yes Dwelling Units: 0 Third: 0 sf Right: 5 Detectors: Total: 561 sf Value: $68,700.06 Rear: 15 PLUMBING Sinks: 0 Water Closets: 1 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 2 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 2 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr. 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 2 Drywell-Trench Drain: 0 Other Fixture Units: Steam Generator and recirculation pump MECHANICAL Fuel Tvoes Air Conditioning: Y Vent Fans: 2 Clothes Dryers: 0 Natural Gas Heat Pump: N Hoods: 0 Other Units: 1 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 1 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 6 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-800 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Ecompasing: NI Other: N Other Description: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 561 Owner: Contractor: NIELSEN,PAUL DAVID&STACEY MOUNTAINWOOD HOMES INC Required Items and Reports(Conditions) 12655 SW 111TH PL PO BOX 2257 1 Ersn Cntri 503-639-4175 TIGARD,OR 97223 BEAVERTON,OR 97075-2257 PHONE: PHONE: 503-746-7338 FAX: Total Fees: $3,876.75 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: holly VI7.4LVe'Were Permittee Signature: {r)vv AppILczttIn-in Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the Job site at the time of each inspection. _ CITY OF TIGARD MASTER PERMIT I' ' COMMUNITY DEVELOPMENT Permit#: MST2021-00172 Date Issued: 05/13/2021 T t _; ' I'. I) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S110DA11400 r Jurisdiction: Tigard Site address: 15109 SW TIERRA TER Subdivision: TRILLIUM HILL Lot: 14 Project: Trillium Hill, Lot 14 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 1392 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 28 Bathrooms: 3 Second: 1746 sf Garage: 412 sf Front: 20 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Total: 3138 sf Value: $391,391.02 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain 0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: Catch Basins: 0 Bckflw Prevntr: 1 Footing Drain: 0 Ice Maker: 1 Hose Bib: 3 Backwater Value: 1 Other Fixtures: 1 Drywell-Trench Drain: 0 Other Fixture Units: Utility Sink-Garage MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 6 201400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other. N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 3138 Owner: Contractor: WEEKLEY HOMES LLC WEEKLEY HOMES Required Items and Reports(Conditions) 1111 NORTH POST OAK RD 1905 NW 169TH PLACE SUITE 102 1 Ersn Cntrl 503-639-4175 HOUSTON,TX 77055 BEAVERTON,OR 97006 PHONE: PHONE: 503-213-4415 FAX: Total Fees: $40,592.39 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232,1987 or 1.800.332.2344. Issued By: HOW)/Vc De/ Vege Permittee Signature: 0 rt.AppU;cat1,ovt Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT N-----. ... Permit#: MST2021-00153 COMMUNITY DEVELOPMENT Date Issued: 05/18/2021 T I G A R f7 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S107AA17000 Jurisdiction: Tigard Site address: 14262 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 170 Project: Polygon at Roshak Ridge, Lot 170 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 5 First: 1527 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 29 Bathrooms: 3 Second: 2187 sf Garage: 705 sf Front: 8 Smoke Yes Right: 5 Detectors: Dwelling Units: 1 Third: 0 sf Ri 9 Total: 3714 sf Value: $494,881.29 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain 0 Storm Sewer: 100 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: Catch Basins: 0Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 7 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Ecompasing: Other: N Other Description: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 3714 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 PHONE PHONE: 360-695-7700 FAX: Total Fees: $47,029.37 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Holly VourvDPiWerge Permittee Signature: On'AppiUcatov Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2021-00161 13125 SW Hall Blvd.,Ti and OR 97223 503.718.2439 Date Issued: 05/10/2021 9 Parcel: 2S103CA00212 Jurisdiction: Tigard Site address: 13140 SW HOWARD DR Subdivision: WOODCREST NO.2 Lot: 24 Project: CALLAWAY Project Description: 75 sq.ft. kitchen addition.-Trade permits to be pulled separately. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 75 sf Basement: 0 sf Left 5 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 20 Smoke Dwelling Units: 0 Third: 0 sf Right: 5 Detectors: Total: 75 sf Value: $68,000.00 Rear: 15 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer. 0 • Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bdcllw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywall-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Tvoes Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm N Vaccuum System: N Garage Opener. N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 75 Owner: Contractor: CALLAWAY,KEVIN J EVERGREEN RENOVATIONS Required Items and Reports(Conditions) 13140 SW HOWARD DR 14605 SW BONANZA CT TIGARD,OR 97223 BEAVERTON,OR 97007 PHONE: PHONE: 503-735-5650 FAX: Total Fees: $2,452.78 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Nally VcusliDe.We.fte PermitteeSignature: 0YliApp1.i.C'.a. Lc-YL Call 503.639.4175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT s COMMUNITY DEVELOPMENT Permit#: MST2021-00149 T 1 GARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 Parcel: 2S107AA14200 Jurisdiction: Tigard Site address: 16611 SW SUNSHINE COAST ST Subdivision: ROSHAK RIDGE Lot: 142 Project: Polygon at Roshak Ridge, Lot 142 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 5 First: 1215 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 28 Bathrooms: 3 Second: 1715 sf Garage: 485 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2930 sf Value: $382,233.30 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amplvoll 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2930 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $43,640.75 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: nattyVary V e'w Permittee Signature:ege 0 vt/Applicati,on Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept In a conspicuous place on the job site until completion of the project. Approved plans are required on the Job site at the time of each Inspection. CITY OF TIGARD MASTER PERMIT •' COMMUNITY DEVELOPMENT Permit#: MST2021-00150 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 T I i-A it t. 9 Parcel: 2S107AA14300 Jurisdiction: Tigard Site address: 16595 SW SUNSHINE COAST ST Subdivision: ROSHAK RIDGE Lot: 143 Project: Polygon at Roshak Ridge, Lot 143 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 925 sf Basement: 0 sf Left. 3 Parking Spaces: 0 Height: 29 Bathrooms: 3 Second: 1188 sf Garage: 422 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2113 sf Value: $279,140.58 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: 0 Catch Basins: 0 Bckflw Prevntr. 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furnc100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener N All Other: N Other Description: Ecompasing: • BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2113 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 One Hour Fire Rated Eaves PHONE: PHONE: 360-695-7700 FAX: Total Fees: $40,372.55 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Ho Vow/ Wege Permittee Signature: 0 in/Appltc i-o-rt Call 503.699.4175 by 7:00 a.m.for the next available inspection date. Thls permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT • COMMUNITY DEVELOPMENT Permit#: MST2021-00152 13125 SW Hall Blvd.,Ti Date Issued: 05/18/2021 T[GAI� f. and OR 97223 503.718.2439 9 Parcel: 2S107AA15000 Jurisdiction: Tigard Site address: 16642 SW SUNSHINE COAST ST Subdivision: ROSHAK RIDGE Lot: 150 Project: Polygon at Roshak Ridge, Lot 150 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 925 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 28 Bathrooms: 3 Second: 1188 sf Garage: 422 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2113 sf Value: $279,140.58 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckfiw Prevntr 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Tvoes Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add.'500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2113 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98860 VANCOUVER,WA 98660 2 One Hour Fire Rated Eaves PHONE: PHONE: 360-695-7700 FAX: Total Fees: $40,371.05 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987or.1..8.0.00..332.2344. Issued By: ffiYUyVci vDe.'Weie Permittee Signature: OWAppifcatI,on Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT IIICOMMUNITY DEVELOPMENT Permit#: MST2021-00156 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 T f G A I;C7 g Parcel: 2S107AA14700 Jurisdiction: Tigard Site address: 16576 SW SUNSHINE COAST ST Subdivision: ROSHAK RIDGE Lot: 147 Project: Polygon at Roshak Ridge, Lot 147 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 5 First: 1242 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 28 Bathrooms: 3 Second: 1722 sf Garage: 486 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors. Yes Total: 2984 sf Value: $386,445.24 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr. 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VP R-3 2964 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 One Hour Fire Rated Eaves VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Ersn Cntrl 503-639-4175 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $43,770.97 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: 1404.lyVa4vDe,Weje Permittee Signature: OIvAp7UC.at'wn Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT _ COMMUNITY DEVELOPMENT Permit*: MST2021-00140 T f C.;A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 Parcel: 2S107AA14100 Jurisdiction: Tigard Site address: 16629 SW SUNSHINE COAST ST Subdivision: ROSHAK RIDGE Lot: 141 Project: Polygon at Roshak Ridge, Lot 141 Project Description: New detached dwelling BUILDING Floor Areas Reauired Setbacks Reauired Stories: 2 Bedrooms: 5 First: 1107 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 28 Bathrooms: 3 Second: 1461 sf Garage: 400 sf Front: B Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2568 sf Value: $333,797.28 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: I 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Yasin : Other: N Other Description: Ecom P 9� BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2568 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $42,171.76 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through h7��OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: V 4 €VwP C Permittee Signature: 0v14p/ 1Lca iifi-n Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept In a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. �t IN CITY OF TIGARD MASTER PERMIT ' a ; COMMUNITY DEVELOPMENT Permit#: MST2021-00101 Date Issued: 05/10/2021 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S134DC00500 Jurisdiction: Tigard Site address: 11476 SW TWIN PARK PL Subdivision: None Lot: None Project: KURAHARA Project Description: Conversion of attached garage into habitable space with (2) bedrooms, (1) bathroom and (1) laundry room. BUILDING Floor Areas Required Setbacks Required Stories: 1 Bedrooms: 2 First: 576 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 1 Second: 0 sf Garage: 0 sf Front: 0 Smoke Detectors: Yes Dwelling Units: 0 Third: 0 sf Right: 0 Total: 576 sf Value: $70,536:96 Rear: 0 PLUMBING Sinks: 0 Water Closets: 1 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 1 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain 0 Storm Sewer: 0 Tubs/Showers: 1 Garbage Disp: 0 Water Heaters: 1 Water Lines: 0 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 1 Clothes Dryers: 1 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 6 Ea add?500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 576 Owner: Contractor: KURAHARA,JORDAN DAIRY FACTORY Required Items and Reports(Conditions) 11476 SW TWIN PARK PL 847 NE 53RD AVE UNIT B PORTLAND,OR 97223 PORTLAND,OR 97213 PHONE: PHONE: 520-270-3319 FAX: Total Fees: $3,521.40 This permit is Issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of Issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Of- thal �tn� On c1 �U ;o.S Issued By: Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. • CITY OF TIGARD MASTER PERMIT NI COMMUNITY DEVELOPMENT Permit#: MST2021-00185 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/20/2021 TIGARD Parcel: 2S102DB01400 Jurisdiction: Tigard Site address: 13230 SW HILL CT Subdivision: BURNHAM PARK Lot: PTS 8-9 Project: Gott Project Description: Solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $2,000.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc!Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea addl 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener N All Other: Y Other Description: Roof Top Solar PV System 5.92 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: GOTT,JANE M PRO STAT SERVICES LLC Required Items and Reports(Conditions) 13230 SW HILL CT 1721 NE 64TH AVE STE 120 PORTLAND,OR 97201 VANCOUVER,WA 98661 PHONE: PHONE: (360)859-3749 FAX: Total Fees: $353.69 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. rt Issued By: t. Permittee Signature: e, _--4--- a 503.639.4175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT III a COMMUNITY DEVELOPMENT Permit#: MST2021-00151 Date Issued: 05/19/2021 T f G A R n 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Parcel: 2S111BA02500 Jurisdiction: Tigard Site address: 14470 SW 100TH AVE Subdivision: TIGARDVILLE HEIGHTS Lot: 30 Project: White Project Description: Assemble pre-built shed with wood floor& roofing shingles (composite)to match home. No foundation BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 9.5 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 20 Smoke Dwelling Units: 0 Third: 0 sf Right: 5 Detectors'. Total: 0 sf Value: $13,910.40 Rear: 5 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain. 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains. 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevnlr. 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstaves: 0 Gas Outlets. 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less. 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: N Other Description: Ecompasing. BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: WHITE, SHANA L&WILLIAM A OWNER Required Items and Reports(Conditions) 14470 SW 100TH AVE 14470 SW 100TH AVENUE TIGARD.OR 97224 TIGARD,OR 97224 PHONE: PHONE 503-704-1582 FAX: Total Fees: $617.36 This permit is issued subject to the regulations contained in the Tigard Municipal Code. State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: }to-UN V( 1J e WP.e Permittee Signature: O1/W Applf cct t't o-rt Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT IIE" COMMUNITY DEVELOPMENT Permit#: MST2021-00170 Date Issued: 05/20/2021 T 1 i;A il.), 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S109AB01100 Jurisdiction: Tigard Site address: 13265 SW BULL MOUNTAIN RD Subdivision: None Lot: None Project: Palmrose Project Description: Rooftop Solar PV BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $2,000.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywall-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc!Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: Y Other Description: Roof Top Solar PV System 8.14 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: SONU,TERESA CHOLCHA PRO STAT SERVICES LLC Required Items and Reports(Conditions) PALMROSE LIVING TRUST 1721 NE 64TH AVE STE 120 BY PALMROSE,GERALD W& VANCOUVER,WA 98661 CATHERINE TRS 13265 SW BULL MOUNTAIN RD PHONE: PHONE: (360)859-3749 FAX: Total Fees: $361.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503,232.1987 or 1.800.332.2344. 7�LtCGLtt011 Issued By: Molly Va.n.'F)eiWeg OYV Apre Permittee Signature: Call 503.639.4176 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT $111COMMUNITY DEVELOPMENT Permit#: MST2021-00110 Date Issued: 05/18/2021 7 I i;A It rr 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S107AA17300 Jurisdiction: Tigard Site address: 14342 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 173 Project: Polygon at Roshak Ridge, Lot 173-Primary Dwelling Project Description: New primary dwelling with (2)attached ADUs on separate permits. BUILDING Floor Areas Required Setbacks Required Stones: 2 Bedrooms: 5 First: 971 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 25.5 Bathrooms: 4 Second: 1437 sf Garage: 477 sf Front: 8 Smoke Yes Right: 3 Detectors: Dwelling Units: 1 Third: 0 sf Ri 9 Total: 2408 sf Value: $317,922.78 Rear: 15 PLUMBING Sinks: 1 Water Closets: 4 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 • Lavatories: 6 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain D Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker. 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 7 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<10OK: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener. N All Y Other: N Other Description: Ecompasing. BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2408 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntri 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98680 2 Fire Rated Conditions PHONE: PHONE: 360-695-7700 FAX: Total Fees: $31,091.61 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. VattiDe&W PermitteeSi nature: OWApp1"'C"rl'Oi`t Issued By:'4�' �e g Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT NI - - COMMUNITY DEVELOPMENT Permit#: MST2021-00111 13125 SW Hall Blvd.,Ti Date Issued: 05/18/2021 TIG,hI;I. and OR 97223 503.718.2439 9 Parcel: 2S107AA17300 Jurisdiction: Tigard Site address: 14344 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 173 Project: Polygon at Roshak Ridge, Lot 173-ADU 1 Project Description: New attached ADU 1 of 2. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 672 sf Basement: 0 sf Left 3 Parking Spaces: 0 Height: 25.5 Bathrooms: 3 Second: 953 sf Garage: 287 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 1625 sf Value: $212,859.60 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 2 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-800 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Securely Alarm: N Vaccuum System: N Garage Opener. N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU VB R-3 1625 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Fire Rated Conditions PHONE: PHONE: 360-695-7700 FAX: Total Fees: $25,547.61 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.17Y 9�8877 or 1.800.332.2344. Issued By: }{D-UIyVaAvDe.We � 4e PermitteeSignature: 0AY ian Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT ' _1111 ~'4 COMMUNITY DEVELOPMENT Permit#: MST2021-00112 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 Parcel: 2S107AA17300 Jurisdiction: Tigard Site address: 14346 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 173 Project: Polygon at Roshak Ridge, Lot 173-ADU 2 Project Description: New attached ADU 2 of 2. BUILDING • Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 720 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 25.5 Bathrooms: 3 Second: 1009 sf Garage: 398 sf Front: 8 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Total: 1729 sf Value: 6230,956.74 Rear. 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bck9w Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<10OK: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/voll: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing. BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU VB R-3 1729 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Fire Rated Conditions PHONE: PHONE: 360-695-7700 FAX: Total Fees: $25,893.98 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through hOAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.198717� or 1.800.332.2344. Issued By: Holly y V Dew 011. PermitteeSignature:ege 0wA l'f' ar Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT IN _ COMMUNITY DEVELOPMENT Permit#: MST2021-00134 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/20/2021 T[G A R n Parcel: 1 S 134AA01100 Jurisdiction: Tigard Site address: 11348 SW IRONWOOD LOOP Subdivision: ENGLEWOOD Lot: 18 Project: Thomas Project Description: Remodel two bathrooms and laundry room. Drywall in kitchen BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $65,000.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr. 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: THOMAS,KIRK CHARTER CONSTRUCTION INC Required Items and Reports(Conditions) MARDEN,BEVERLY 3747 SE 8TH AVENUE 11348 SW IRONWOOD LOOP PORTLAND,OR 92020 TIGARD,OR 97223 PHONE: . PHONE: 503-546-2600 FAX: Total Fees: $1,564.55 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 160 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: 0-12y V awl,n ,We.O.e Permittee Signature: OWAppltcat't.on Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. illigCITY OF TIGARD MASTER PERMIT _ COMMUNITY DEVELOPMENT Permit#: MST2021-00129 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/17/2021 TIGARD Parcel: 1 S 125DD03900 Jurisdiction: Tigard Site address: 9855 SW VENTURA CT Subdivision: WASHINGTON SQUARE ESTATES NO.2 Lot: 47 Project: Johnson Project Description: Converting crawlspace into additional bedroom&235 unfinished storage room. Trade permits to be pulled separately. BUILDING Floor Areas Required Setbacks Reauired Stories: 0 Bedrooms: 1 First: 0 sf Basement: 230 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Yes Total: 230 sf Value: $39,516.30 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr. 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr. 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 230 Owner: Contractor: JOHNSON,MATTHEW&ANDREA 8 INCH NAILS CONSTRUCTION Required Items and Reports(Conditions) 9855 SW VENTURA CT 7823 SW CEDAR CREST ST TIGARD,OR 97223 PORLAND,OR 97233 PHONE: PHONE: 503453-0786 FAX: Total Fees: $1,421.77 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through]7 "OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. R Issued By: ROILY Vaw t1C"We9.e Permittee Signature: O✓/App Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT 114 .. s ' COMMUNITY DEVELOPMENT Permit#: MST2021-00069 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/12/2021 Parcel: 2S107AA13900 Jurisdiction: Tigard Site address: 16671 SW SUNSHINE COAST ST Subdivision: ROSHAK RIDGE Lot: 139 Project: Polygon at Roshak Ridge, Lot 139-Primary Dwelling Project Description: New primary dwelling with(1)ADU on separate permit. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 82 sf Basement: 0 sf Left: 3 Parking Spaces: Cl Height: 26 Bathrooms: 3 Second: 1941 sf Garage: 415 sf Front: 12 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2023 sf Value: $273,603.48 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100Catch Basins: 0 Bcktlw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 1 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 6 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2023 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 One Hour Fire Rated Eaves PHONE: PHONE: 360-695-7700 FAX: Total Fees: $29,556.82 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 9552-001--,( T 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1J1..8000.333'2.2344. Issued By: q L) l p(_i�t_�v Permittee Signature: M1, (i1 t' i.1 1) 1 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the lob site until completion of the project. Approved plans are required on the job site at the time of each inspection. N.,,, . CITY OF TIGARD MASTER PERMIT I COMMUNITY DEVELOPMENT Permit#: MST2021-00071 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/12/2021 Parcel: 2S107AA13900 Jurisdiction: Tigard Site address: 16673 SW SUNSHINE COAST ST Subdivision: ROSHAK RIDGE Lot: 139 Project: Polygon at Roshak Ridge, LOT 139 -ADU Project Description: New attached ADU. BUILDING Floor Areas Required Setbacks Required Stories: 1 Bedrooms: 3 First: 1228 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 26 Bathrooms: 2 Second: sf Garage: 265 sf Front: 12 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 1228 sf Value: $163,180.38 Rear: 10 PLUMBING Sinks: 1 Water Closets: 2 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 3 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 3 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 1 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU VB R-3 1228 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 One Hour Fire Rated Eaves PHONE: PHONE: 360-695-7700 FAX: Total Fees: $24,346.01 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 throughug OAR 952-001-0090.09 You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987^ or 1.800.332.2344. r Issued By: (V 1- j bO. _Q_ 1 Permittee Signature: 1 ,Arv-.ck Call 503.639.4175 by 7:00 a.m.for the next available inspection date. Thls permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT I COMMUNITY DEVELOPMENT Permit#: MST2021-00079 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/12/2021 TIGARD 9 Parcel: 2S107AA15100 Jurisdiction: Tigard Site address: 16656 SW SUNSHINE COAST ST Subdivision: ROSHAK RIDGE Lot: 151 Project: Polygon at Roshak Ridge, Lot 151 -ADU Project Description: New attached ADU. BUILDING Floor Areas Required Setbacks Required Stories: 1 Bedrooms: 3 First: 1228 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 26 Bathrooms: 2 Second: 0 sf Garage: 265 sf Front: 12 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 1228 sf Value: $163,294.33 Rear: 10 PLUMBING Sinks: 1 Water Closets: 2 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 3 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: Catch Basins: 0 BckFlw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 3 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea addl 500 sf: 1 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU VB R-3 1228 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 One Hour Fire Rated Eaves PHONE: PHONE: 360-695-7700 FAX: Total Fees: $24,346.14 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth In OAR 952-001-0010 through OAR 952-001-0090.� You maymay obtain a copy of the rules or direct questions to OUNC by callin+g�503.232.1987 or 1.800.332.2344._ .3 Issued By: �JX4f )90 l�1]t . t Permittee Signature: V 1" 3erf.:[A 1' .( Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each Inspection. CITY OF TIGARD MASTER PERMIT 3. . COMMUNITY DEVELOPMENT • Permit#: MST2021-00078 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/12/2021 T I{"�g'O g Parcel: 2S107AA15100 Jurisdiction: Tigard Site address: 16654 SW SUNSHINE COAST ST Subdivision: ROSHAK RIDGE Lot: 151 Project: Polygon at Roshak Ridge, Lot 151 -Primary Dwelling Project Description: New primary dwelling with (1)attached ADU on separate permit. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 82 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 26 Bathrooms: 3 Second: 1941 sf Garage: 415 sf Front: 12 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2023 sf Value: $273,808.33 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 1 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea addl 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2023 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 One Hour Fire Rated Eaves PHONE: PHONE: 360-695-7700 FAX: Total Fees: $29,532.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 throughro/( OAAR`952(-001--00090. You may obtain a copy of the rules or direct questions to OUNC by callingr503.232.1987 or 1.800.332.2344. Issued By: �WA\SJU IJJUdI 9.14 Permittee Signature: u'l q2PlicatiN Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the Job site until completion of the project. Approved plans are required on the job site at the time of each Inspection. CITY OF TIGARD MASTER PERMIT 1 ' COMMUNITY DEVELOPMENT Permit#: MST2021-00081 TTGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/12/2021 Parcel: 2S 107AA15200 Jurisdiction: Tigard Site address: 16682 SW SUNSHINE COAST ST Subdivision: ROSHAK RIDGE Lot: 152 Project: Polygon at Roshak Ridge, Lot 152-ADU Project Description: New attached ADU. BUILDING Floor Areas Required Setbacks Required Stories: 1 Bedrooms: 3 First: 1228 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 25 Bathrooms: 2 Second: 0 sf Garage: 275 sf Front: 12 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 1228 sf Value: $163,663.38 Rear: 10 PLUMBING Sinks: 1 Water Closets: 2 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 3 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckfw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 3 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add,500 sf: 2 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU VB R-3 1228 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 One Hour Fire Rated Eaves PHONE: PHONE: 360-695-7700 FAX: Total Fees: $24,384.58 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. a. Issued By: CZ& 9✓W�_. 29 Permittee Signature: 7 0 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT IIa COMMUNITY DEVELOPMENT Permit#: MST2021-00080 T(GARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date issued: 05/12/2021 Parcel: 2S107AA15200 Jurisdiction: Tigard Site address: 16680 SW SUNSHINE COAST ST Subdivision: ROSHAK RIDGE Lot: 152 Project: Polygon at Roshak Ridge, Lot 152-Primary Dwelling Project Description: New primary dwelling with (1)attached ADU,on separate permit, and 116 sf deck and deck cover. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 82 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 25 Bathrooms: 3 Second: 1941 sf Garage: 456 sf Front: 12 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2023 sf Value: $275,389.70 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: Catch Basins: 0 Bckfiw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 1 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2023 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 One Hour Fire Rated Eaves PHONE: PHONE: 360-695-7700 FAX: Total Fees: $29,581.88 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: i .. cp'Q'L r Permittee Signature: O11 o IICSa-t iU 4Nt Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the Job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT UPI _ . COMMUNITY DEVELOPMENT Permit#: MST2021-00131 T I G A R f.7 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/03/2021 Parcel: 2S107AA16700 Jurisdiction: Tigard Site address: 14190 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 167 Project: Polygon at Roshak Ridge, Lot 167 Project Description: New detached dwelling. NO FINAL INSP UNTIL FEES PAID FOR SDCs DEFERRED TO OCCUPANCY. BUILDING Floor Areas Required Setbacks Required Stories: 1 Bedrooms: 4 First: 2776 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 20 Bathrooms: 3 Second: 0 sf Garage: 684 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2776 sf Value: $372,986.16 Rear: 20 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: Catch Basins: 0 Bckfiw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types _ Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add,500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr. 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2776 Owner: Contractor: POLYGON WLH LLC WLLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $43,242.88 This permit is issued subject to the regulations contained in the Tigard Municipal Code. State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232..11�978�7 or 1.800.332.2344. Issued By: 1LoU,ly Vcwti De,Wege Permlttee Signature: O W Ar�JLf c47tA1't Call 603.639.4176 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. INCITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2O21-00141 T I GARL3 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/03/2021 Parcel: 2S 107AA17200 Jurisdiction: Tigard Site address: 14320 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 172 Project: Polygon at Roshak Ridge, Lot 172 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 1569 of Basement 0 sf Left: 3 Parking Spaces: 0 Height: 27 Bathrooms: 3 Second: 1865 sf Garage: 688 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 3434 sf Value: $453,758.04 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: • ' MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 . Ea add!500 sf: 7 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 3434 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $45,861.33 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.19872.9 or 1.800.332.2344. Issued By: lU.Y L0Va iDe,Weg-e Permittee Signature: Dn/App1CCC On Call 603.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT ' COMMUNITY DEVELOPMENT PermitU: MST2021-00139 -TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/03/2021 Parcel: 2S 107AA 14000 Jurisdiction: Tigard Site address: 16647 SW SUNSHINE COAST ST Subdivision: ROSHAK RIDGE Lot: 140 Project: Polygon at Roshak Ridge, Lot 140 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First 925 at Basement 0 sf Left 3 Parking Spaces: 0 Height: 28 Bathrooms: 3 Second: 1188 sf Garage: 422 sf Front: 8 Smoke Dwelling Units: 0 Third: 0 sf Right: 3 Detectors: Yes Total: 2113 sf Value: $279,140.58 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temo Srvc!Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2113 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 96660 2 One Hour Fire Rated Eaves PHONE: PHONE: 380-695-7700 FAX: Total Fees: $40,372.55 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. OYt7A Ucati,cm. Issued By: H �O Va.fvD/Wege Permittee Signature: rr Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job she until completion of the project. Approved plans are required on the job site at the time of each inspection. NICITY OF TIGARD MASTER PERMIT i COMMUNITY DEVELOPMENT Permit#: MST2021-00138 f G A R T.D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/04/2021 T Parcel: 1 S 135CC06100 Jurisdiction: Tigard Site address: 11874 SW PENNY LN Subdivision: BURT'S LANDING Lot: 13 Project: Burt's Landing, Lot 13 Project Description: New detached dwelling BUILDING Floor Areas Reauired Setbacks Required Stories: 2 Bedrooms: 4 First: 1059 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 24 Bathrooms: 3 Second: 1567 sf Garage: 676 sf Front: 20 Smoke Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Yes Total: 2626 sf Value: $354,230.76 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 1 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 VVoodstoves: 0 Gas Outlets: 5 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener. N All Other: NI Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2626 Owner: Contractor: WESTWOOD HOMES LLC WESTWOOD HOMES LLC Required Items and Reports(Conditions) 12700 NW CORNELL RD 12700 NW CORNELL RD 1 Ersn Cntrl 503-639-4175 PORTLAND,OR 97229 PORTLAND,OR 97229 PHONE: PHONE: 503-330-2215 FAX: 503-342-2403 Total Fees: $39,387.52 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: UD-11N VGW/De,Werie Permittee Signature: DWAppUco uTri. Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT 11111 I COMMUNITY DEVELOPMENT Permit#: MST2021-00126 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/04/2021 T I(.+\k.f7 g Parcel: 1S135CC06300 Jurisdiction: Tigard Site address: 10404 SW LUCY CT Subdivision: BURT'S LANDING Lot: 15 Project: Burt's Landing, Lot 15 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stones: 2 Bedrooms: 3 First: 1694 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 22 Bathrooms: 3 Second: 737 sf Garage: 524 sf Front: 20 Smoke Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Yes Total: 2431 sf Value: $323,009.46 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 1 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Tvnes Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 5 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temo SrvclFeeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 4 201-400 amp: 0 201-400 amp. 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio 8 Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2431 Owner: Contractor: WESTWOOD HOMES LLC WESTWOOD HOMES LLC Required Items and Reports(Conditions) 12700 NW CORNELL RD 12700 NW CORNELL RD 1 Ersn Cntrl 503-639-4175 PORTLAND,OR 97229 PORTLAND,OR 97229 PHONE: PHONE: 503-330-2215 FAX. 503-342-2403 Total Fees: $38,511.78 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION, Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Rally VawDeWe9e Permittee Signature: O VI/AppliCatCov1 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT " ' COMMUNITY DEVELOPMENT1114 Permit#: MST2 02 1-0001 3 T I GA RD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/06/2021 Parcel: 2S110BA03500 Jurisdiction: Tigard Site address: 11575 SW CLOUD CT Subdivision: SHADOW HILLS Lot: 30 Project: Herboth Project Description: 310 sq.ft.two-story addition. Adding (1)bedroom and expanding(1)bedroom. BUILDING Floor Areas Required Setbacks Required Stones: 2 Bedrooms: 1 First: 145 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 15 Bathrooms: 0 Second: 165 sf Garage: 0 sf Front: 30 Smoke Dwelling Units: 0 Third: 0 sf Right: 5 Detectors: Yes Total: 310 sf Value: $37,962.50 Rear. 25 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ADD SF VB R-3 313 Owner: Contractor: AGARD,KIRSTEN ERIN WM D HERBOTH REMODELING INC Required Items and Reports(Conditions) HERBOTH,GLENN ALBERT 6008 NE RODNEY AVE 11575 SW CLOUD CT PORTLAND,OR 97211 TIGARD,OR 97224 PHONE: PHONE: 503-289-1600 FAX: Total Fees: $1,656.79 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through7' OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Lo7wy V DeJWce Permittee Signature: DVliAPP A.Catt.0-Y1 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT II ' ' COMMUNITY DEVELOPMENT Permit#: BUP2021-00041 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 514/2021 T[C �R.>i Parcel: 2S103DD00700 Jurisdiction: Tigard Site address: 13769 SW PACIFIC HWY Project: Dutch Bros Coffee Subdivision: None Lot: None Project Description: A new 500 s .ft.drive-through coffee building. p q 9 9 Contractor: LUNA DESIGN&CONSTRUCTION LLC Owner: GROUND 99 LLC 1709 NE CONIFER BLVD 610 SW ALDER ST STE 1221 CORVALLIS, OR 97330 PORTLAND,OR 97205 PHONE: 503-702-1851 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 05/04/2021 $3,219.95 Demolition Occupancy Grp: Occupancy Load: 5 12%State Surcharge-Building 05/04/2021 $386.39 Dwelling Units: 0 Plan Review 02/09/2021 $2,092.97 Stories: 1 Height: 20 ft DC Provision Review,COM New-Bldg 05/04/2021 $205.00 Bedrooms: 0 Bathrooms: 1 DC Provision Review, COM New-Ping 05/04/2021 $205.00 Value: $450,000 Plan Review-Fire Life Safety 05/04/2021 $1,287.98 Info Process/Archiving-Lg$2.00(over 05/04/2021 $134.00 11x17) Floor Areas: Info Process/Archiving-Sm$0.50(up to 05/04/2021 $22.00 11x17) Total Area: 500 Metro CET 05/04/2021 $540.00 Accessory Struct: 0 Tigard CET-Non-Residential-Admin 05/04/2021 $180.00 Basement: 0 Tigard CET-Non-Residential-AH 05/04/2021 $4,320.00 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $12,593.29 Required: Required Items and Reports(Conditions) 1 Special Inspection(see plans) Fire Sprinkler: No Parapet: Yes Fire Alarm: No Protected Corridors: No Smoke Detectors: No Manual Pull Stations: No Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Permittee Signature: r gria4zr:,460.„: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT COMMUNITY DEVELOPMENT Permit#: BUP2021-00062 T r G A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/4/2021 Parcel: 1S1260000300 Jurisdiction: Tigard Site address: 9348 SW WASHINGTON SQUARE RD W14A Project: Sunglass Hut Subdivision: None Lot: None Project Description: TI for new tenant:New storefront,interior partitions,ceiling,lighting,and finishes. Contractor: JAMES HUNT CONSTRUCTION Owner: PPR WASHINGTON SQUARE LLC 1865 SUMMIT RD BY MACERICH RET CINCINNATI, OH 45237 PO BOX 4085 SANTA MONICA, CA 90411 PHONE: 513-298-2553 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: IIB Permit Fee-Additions,Alterations, 04/27/2021 $1,238.83 Demolition Occupancy Grp: M Occupancy Load: 17 12%State Surcharge-Building 04/27/2021 $148.66 Dwelling Units: 0 Plan Review 03/11/2021 $805.24 Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 04/27/2021 $257.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 04/27/2021 $495.53 Value: $122,000 Info Process/Archiving-Lg$2.00(over 04/27/2021 $70.00 11x17) Info Process/Archiving-Sm$0.50(up to 04/27/2021 $6.00 Floor Areas: 11x17) Metro CET 04/27/2021 $146.40 Total Area: 0 Tigard CET-Non-Residential-Admin 04/27/2021 $48.80 Accessory Struct: 0 Tigard CET-Non-Residential-AH 04/27/2021 $1,171.20 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $4,387.66 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: `^'Y .Ho Vc1.fvDeiwp Permittee Signature: O vApp to-rt Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT 1 COMMUNITY DEVELOPMENT Permit#: BUP2021-00077 13125 SW Hall Blvd.,Ti Date Issued: 5/6/2021 Ttc;gap and OR 97223 503.718.2439 9 Parcel: 1 S 126 DC03300 Jurisdiction: Tigard Site address: 9900 SW GREENBURG RD 275 Project: Greenburg Commons Subdivision: LEHMANN ACRE TRACT Lot: 5 Project Description: New non-bearing wall to create(1)office,add door and relite to existing non-rated/non-bearing wall. New carpet and paint. Contractor: JHC COMMERCIAL LLC Owner: MADRONA GREENBURG LLC 11125 SW BARBUR BLVD BLD C 210 SW MORRISON ST PORTLAND, OR 97219 PORTLAND, OR 97204 PHONE: 503-624-7100 PHONE: FAX: 503-684-5295 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 05/06/2021 $225.80 Demolition Occupancy Grp: B Occupancy Load: 13 12%State Surcharge-Building 05/06/2021 $27.10 Dwelling Units: 0 Plan Review 04/01/2021 $146.77 Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 05/06/2021 $103.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 05/06/2021 $90.32 Value: $10,000 Info Process/Archiving-Lg$2.00(over 05/06/2021 $2.00 11x17) Info Process/Archiving-Sm$0.50(up to 05/06/2021 $0.50 Floor Areas: 11x17) Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $595.49 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344_ Issued By: Hotly' Va4wl4e/we.4e Permittee Signature: Pp Otti� UcatLo-n Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the Job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT 111 COMMUNITY DEVELOPMENT Permit#: BUP2021-00088 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/5/2021 T f t;r1 li i) 9 Parcel: 2S112DA00700 Jurisdiction: Tigard Site address: 15333 SW SEQUOIA PKWY Project: PacTrust Subdivision: PACIFIC CORPORATE CENTER Lot: 3 Project Description: Expansion/Alteration of existing building electrical room. Contractor: PACIFIC REALTY ASSOCIATES LP Owner: PACIFIC REALTY ASSOCIATES LP 15350 SW SEQUOIA PKWY#300 ATTN: N PIVEN PORTLAND, OR 97224 15350 SW SEQUOIA PKWY#300 PORTLAND, OR 97224 PHONE: 503-624-6300 PHONE: FAX: 503-624-7755 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: IIB Permit Fee-Additions,Alterations, 05/05/2021 $180.17 Demolition Occupancy Grp: B Occupancy Load: 0 12%State Surcharge-Building 05/05l2021 $21.62 Dwelling Units: 0 Plan Review 04/19/2021 $117.11 Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 05/05/2021 $103.00 Bedrooms: 0 Bathrooms: 0 Info Process/Archiving-Lg$2.00(over 05/05/2021 $2.00 Value: $7,000 11x17) Info Process/Archiving-Sm$0.50(up to 05/05/2021 $6.00 11x17) Floor Areas: Plan Review-Fire Life Safety 05/05/2021 $72.07 Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 • Garage: 0 Mezzanine: 0 Total $501.97 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: • Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344_ Issued By: j{oay Va..' De/Wecje Permittee Signature: Ov iAppU,catwn Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT 11,1 '. ' COMMUNITY DEVELOPMENT Permit#: BUP2021-00089 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/5/2021 T l C:,41t.f 9 Parcel: 2S113AB00600 Jurisdiction: Tigard Site address: 16165 SW 72ND AVE Project: Ednetics Subdivision:COUNCIL VIEW ACRES(LOTS 21-44) Lot: 30 Project Description: Remodel of 11,056 sf of office&warehouse.Work includes selected demo of existing nonstructural walls, nonstructural drywall/metal stud wall/metal stud walls,doors/frames,painting,electrical distribution,lighting. Contractor: PACIFIC REALTY ASSOCIATES LP Owner: PACIFIC REALTY ASSOCIATES LP 15350 SW SEQUOIA PKWY#300 ATTN: N PIVEN PORTLAND, OR 97224 15350 SE SEQUOIA PKWY#300 PORTLAND, OR 97224 PHONE: 503-624-6300 PHONE: FAX: 503-624-7755 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: IIIB Permit Fee-Additions,Alterations, 05/04/2021 $498.03 Demolition Occupancy Grp: B Occupancy Load: 49 12%State Surcharge-Building 05/04/2021 $59.76 Dwelling Units: 0 Plan Review 04/15/2021 $323.72 Stories: 0 Height: 0 ft DC Provision Review, COM TI-Ping 05/04/2021 $103.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 05/04/2021 $199.21 Value: $28,628 Info Process/Archiving-Lg$2.00(over 05/04/2021 $8.00 11x17) Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $1,191.72 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Holly V ourvt,e,Wege Perm ittee Signature: OA/AppUc t Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the Joh site until completion of the project. Approved plans are required on the job site at the time of each inspection. 1111 CITY OF TIGARD BUILDING PERMIT 41 COMMUNITY DEVELOPMENT Permit#: BUP2021-00081 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/5/2021 T I G A R p 9 Parcel: 2S112AC00600 Jurisdiction: Tigard Site address: 7440 SW BONITA RD Project: Portland Compressor Subdivision: None Lot: None Project Description: Install canopy over entrance Contractor: PIKE AWNING CO Owner: RL WILSON PROPERTIES LLC 7300 SW LANDMARK LN 9204 NW MCKENNA DR PORTLAND, OR 97224 PORTLAND, OR 97229 PHONE: 503-624-5600 PHONE: FAX: 503-968-5440 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 04/22/2021 $256.22 Demolition Occupancy Grp: U Occupancy Load: 0 12%State Surcharge-Building 04/22/2021 $30.75 Dwelling Units: 0 Plan Review 04/06/2021 $166.54 Stories: 0 Height: 0 ft Info Process/Archiving-Sm$0.50(up to 04/22/2021 $12.00 Bedrooms: 0 Bathrooms: 0 11x17) Value: $11,950 Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $465.51 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION. Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR • 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Permittee Signature: p A y 1�7 .0 /r lii.ITf I,/VraM i 17P,War �t�/A j U a r.I. (/ Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. g 711 CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT a�r Permit#: MST2021-00138 ` Date Issued: 05/04/2021 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S135CC06100 Jurisdiction: Tigard Site address: 11874 SW PENNY LN Subdivision: BURT'S LANDING Lot: 13 Project: Burt's Landing, Lot 13 Project Description: New detached dwelling. 8/18/2021: REPRINT permit to add (1)utility sink. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 1059 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 24 Bathrooms: 3 Second: 1567 sf Garage: 676 sf Front: 20 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Total: 2626 sf Value: $354,230.76 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 1 Drywell-Trench Drain: 0 Other Fixtures: 1 Other Fixture Units: Utility sink MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 5 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea addl 500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 1 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2626 Owner: Contractor: WESTWOOD HOMES LLC WESTWOOD HOMES LLC Required Items and Reports(Conditions) 12700 NW CORNELL RD 12700 NW CORNELL RD 1 Ersn Cntrl 503-639-4175 PORTLAND,OR 97229 PORTLAND,OR 97229 PHONE: PHONE: 503-330-2215 FAX: 503-342-2403 Total Fees: $39,415.54 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR O,9-nn1-nnln thrn„n nAR Q59-n non Yn,,may nhmin n rnnv of tha rninc nr riirort nimetinne to Al IN(:by railinn cn1 919 10S7 nr 1 ;Inn 110 9'i41 (,,,. ..5 #q# Issued By: `` Permittee Signature: ly g Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT N . . , COMMUNITY DEVELOPMENT Permit#: MST2021-00096 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 TIC;;112 f7 g Parcel: 2S107AA16500 Jurisdiction: Tigard Site address: 14134 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 165 Project: Polygon at Roshak Ridge, Lot 165-ADU 2 Project Description: New attached ADU, 2 of 2. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 720 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 22.5 Bathrooms: 3 Second: 1009 sf Garage: 398 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 1729 sf Value: $230,956.74 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains. 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea addl 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU VB R-3 1729 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Fire Rated Conditions PHONE: PHONE 360-695-7700 FAX: Total Fees: $25,893.98 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Holly v 'VC'W Permittee Signature: 0 AppUcG t o-n Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2021-00095 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 TIC;;k I:f? 9 Parcel: 2S107AA16500 Jurisdiction: Tigard Site address: 14132 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 165 Project: Polygon at Roshak Ridge, Lot 165-ADU 1 Project Description: New attached ADU, 1 of 2. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 672 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 22.5 Bathrooms: 3 Second: 953 sf Garage: 287 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 1625 sf Value: $212,859.60 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 2 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Ecom asin Y Other: N Other Description: p g BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU VB R-3 1625 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Fire Rated Conditions PHONE: PHONE: 360-695-7700 FAX: Total Fees: $25,547.61 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.19987 or 1.800.332.2344. Issued By: 1 'Uy V DeJwege Permittee Signature: 0wAI'1�t�8U'aJt,0 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. W CITY OF TIGARD MASTER PERMIT III 1 COMMUNITY DEVELOPMENT Permit#: MST2021-00093 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 T 1 c;A i2 C7 9 Parcel: 2S107AA16500 Jurisdiction: Tigard Site address: 14130 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 165 Project: Polygon at Roshak Ridge, Lot 165-Primary Dwelling Project Description: New primary dwelling with (2)attached ADUs on separate permits. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 5 First: 971 sf Basement: 0 sf Left 3 Parking Spaces: 0 Height: 22.5 Bathrooms: 4 Second: 1437 sf Garage: 477 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2408 sf Value: $317,922.78 Rear: 15 PLUMBING Sinks: 1 Water Closets: 4 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 6 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 7 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener N All Ecom asin Y Other: N Other Description: p g BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2408 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Fire Rated Conditions PHONE: PHONE: 360-695-7700 FAX: Total Fees: $31,117.73 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Holly VANVDPiwP.�E Permittee Signature: Oyu AppLt,( (TVL Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Nn CITY OF TIGARD BUILDING PERMIT I. COMMUNITY DEVELOPMENT Permit#: BUP2021-00103 Ti R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/19/2021 t;pry Parcel: 1 S 1260000300 Jurisdiction: Tigard Site address: 9681 SW WASHINGTON SQUARE RD C06 Project: Fabletics Subdivision: None Lot: None Project Description: Installation of stockroom shelving rolling rack system Contractor: COMMERCIAL CONTRACTORS INC Owner: PPR WASHINGTON SQUARE LLC 16745 COMSTOCK ST BY MACERICH RET GRAND HAVEN, MI 49417 PO BOX 4085 SANTA MONICA, CA 90411 PHONE: 616-850-1289 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VB Permit Fee-Additions,Alterations, 05/19/2021 $225.80 Demolition Occupancy Grp: M Occupancy Load: 0 12%State Surcharge-Building 05/19/2021 $27.10 Dwelling Units: 0 Plan Review 04/29/2021 $146.77 Stories: 0 Height: 0 ft Plan Review-Fire Life Safety 05/19/2021 $90.32 Bedrooms: 0 Bathrooms: 0 Info Process/Archiving-Lg$2.00(over 05/19/2021 $4.00 Value: $10,000 11x17) Info Process/Archiving-Sm$0.50(up to 05/19/2021 $3.00 11x17) Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $496.99 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Haay WM/De/Wege Permittee Signature: 01/1/A pp 7. _tin t.Luu. Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2021-00137 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 T t c;;�I£T� 9 Parcel: 2S107AA17100 Jurisdiction: Tigard Site address: 14288 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 171 Project: Polygon at Roshak Ridge, Lot 171 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 1 Bedrooms: 3 First: 1819 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 17 Bathrooms: 3 Second: 0 sf Garage: 430 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 1819 sf Value: $243,523.74 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 6 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea addi 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener N All Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 1819 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $39,318.67 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Holly Va De'w ow�4ppLt;Caz'w-Y1. Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT N . . COMMUNITY DEVELOPMENT Permit#: MST2021-00155 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 T l�''L l{�� g Parcel: 2S107AA14900 Jurisdiction: Tigard Site address: 16604 SW SUNSHINE COAST ST Subdivision: ROSHAK RIDGE Lot: 149 Project: Polygon at Roshak Ridge, Lot 149 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 5 First: 1225 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 28 Bathrooms: 3 Second: 1723 sf Garage: 486 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2948 sf Value: $384,485.88 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener N All Ecompasing: Y Other: N Other Description: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2948 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 PHONE: PHONE 360-695-7700 FAX: Total Fees: $43,702.14 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.11987 or 1.800.332.2344. Issued By: Holly V De.wege Permittee Signature: 0wAPPliCa' C07/1 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT • COMMUNITY DEVELOPMENT Permit#: MST2021-00113 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 T f G A R T� 9 Parcel: 2S107AA17400 Jurisdiction: Tigard Site address: 14374 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 174 Project: Polygon at Roshak Ridge, Lot 174 Primary Dwelling Project Description: New primary dwelling with (2)attached ADUs on separate permits. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 5 First: 971 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 25.5 Bathrooms: 4 Second: 1437 sf Garage: 477 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2408 sf Value: $317,922.78 Rear: 15 PLUMBING Sinks: 1 Water Closets: 4 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 6 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 7 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add]500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2408 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Fire Rated Conditions VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Ersn Cntrl 503-639-4175 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $31,117.73 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Holly VafvDe'Wec e O w A 1icat'f o-vt. Issued By: Permittee Signature: pp Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT : �2 ' COMMUNITY DEVELOPMENT Permit#: MST2021 00114 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 T I c;A f,T) 9 Parcel: 2S107AA17400 Jurisdiction: Tigard Site address: 14270 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 174 Project: Polygon at Roshak Ridge, Lot 174 ADU 1 Project Description: New attached ADU 1 of 2. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 672 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 25.5 Bathrooms: 3 Second: 953 sf Garage: 287 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 1625 sf Value: $212,859.60 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 2 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU VB R-3 1625 Owner: Contractor: _ POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Fire Rated Conditions PHONE: PHONE: 360-695-7700 FAX: Total Fees: $25,547.61 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.8�000..3�3.2.2344. }foU w yVa. De.Wege O wl Issued By: Permittee Signature: pptttt�tt.idYl Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT a . COMMUNITY DEVELOPMENT Permit#: MST2021-00115 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 T 1��'� T7 9 Parcel: 2S107AA17400 Jurisdiction: Tigard Site address: 14272 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 174 Project: Polygon at Roshak Ridge, Lot 174 ADU 2 Project Description: New attached ADU 2 of 2. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 720 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 25.5 Bathrooms: 3 Second: 1009 sf Garage: 398 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 1729 sf Value: $230,956.74 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener. N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU VB R-3 1729 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Fire Rated Conditions PHONE: PHONE: 360-695-7700 FAX: Total Fees: $25,893.98 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: HOUyVctvvDe-Wecre Permittee Signature: OwAppliCatian Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT IN _ . ' COMMUNITY DEVELOPMENT Permit#: MST2021-00099 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 T i(;;1(2!� 9 Parcel: 2S107AA16600 Jurisdiction: Tigard Site address: 14158 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 166 Project: Polygon at Roshak Ridge, Lot 166-ADU 2 Project Description: New attached ADU 2 of 2. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 720 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 25.5 Bathrooms: 3 Second: 1009 sf Garage: 398 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 1729 sf Value: $230,956.74 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Tvoes Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener. N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU VB R-3 1729 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Fire Rated Conditions PHONE: PHONE: 360-695-7700 FAX: Total Fees: $25,893.98 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Ho Vcwi'De'We�e Permittee Signature: 0niApplf cat'wn Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. 11111 "I CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2021-00098 T[GARE) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 Parcel: 2S107AA16600 Jurisdiction: Tigard Site address: 14156 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 166 Project: Polygon at Roshak Ridge, Lot 166-ADU 1 Project Description: New attached ADU 1 of 2. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 672 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 25.5 Bathrooms: 3 Second: 953 sf Garage: 287 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 1625 sf Value: $212,859.60 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'500 sf: 2 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU VB R-3 1625 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Fire Rated Conditions PHONE: PHONE: 360-695-7700 FAX: Total Fees: $25,547.61 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232..1987 or 1.800.332 2344. Issued By: .ally VavvDeilVege Permittee Signature: 0 VI,A►"p itrn Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. INCITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2021-00097 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/18/2021 T t c;A R.f� g Parcel: 2S107AA16600 Jurisdiction: Tigard Site address: 14160 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 166 Project: Polygon at Roshak Ridge, Lot 166-Primary Dwelling Project Description: New primary dwelling with(2)attached ADUs on separate permits. BUILDING Floor Areas Reauired Setbacks Required Stories: 2 Bedrooms: 5 First: 971 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 25.5 Bathrooms: 4 Second: 1437 sf Garage: 477 sf Front: 8 Smoke Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Yes Total: 2408 sf Value: $317,922.78 Rear: 15 PLUMBING Sinks: 1 Water Closets: 4 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 6 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 7 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2408 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Fire Rated Conditions PHONE: PHONE: 360-695-7700 FAX: Total Fees: $31,117.73 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1779�887 or 1.800.332.2344. Issued By: 1IoUy Val f'ti e,WP.e Permittee Signature: 0ivA 1''f 'artfirn Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT g~: + COMMUNITY DEVELOPMENT Permit#: MST2021-00536 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 2S/18/2022 Parcel: 2S108AB01300 Jurisdiction: Tigard Site address: 15404 SW SILKWOOD CT Subdivision: BULL MOUNTAIN SUMMIT Lot: Project: Bull Mountain Summit, Lot 1 Project Description: New detached dwelling. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 1302 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 22.5 Bathrooms: 3 Second: 1413 sf Garage: 425 sf Front: 15 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Total: 2715 sf Value: $376,318.70 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach; 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins; 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 1 Drywell-Trench Drain: 0 Other Fixtures: 1 Other Fixture Units: Bar sink MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less; 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add1500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2715 • Owner: Contractor: KEMMER RIDGE LLC CHAD E DAVIS CONSTRUCTION Required Items and Reports(Conditions) 12555 SW HALL BLVD 2808 19TH AVE 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97223 FOREST GROVE,OR 97116 PHONE: PHONE: 503-357-8587 FAX: Total Fees: $40,859.97 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or If work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification en Tho r eS t forth in OAR oF9-nn1_nnln Ihrnunh rI ,e 0S9-nn l-anon Vn,,maw nhtain a rnnw of the n,lea nr rtircrt nu<ctinnc to rll Ihlrt hw rallinn Fill 9 Issued By: TL!s ----.agtr � Permittee Signature: 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. CITY OF TIGARD MASTER PERMIT ',i� COMMUNITY DEVELOPMENT Permit#: MST2021-00524 Date Issued: 05/18/2022 TI GpRT) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 25108AB01300 Jurisdiction: Tigard Site address: 15398 SW SILKWOOD CT Subdivision: BULL MOUNTAIN SUMMIT Lot: Project: Bull Mountain Summit, Lot 2 Project Description: New detached dwelling. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms; 4 First: 1085 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 24 Bathrooms: 3 Second: 1495 sf Garage: 686 sf Front: 15 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Total: 2580 sf Value: $372,074.48 Rear; 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: Storm Sewer: 100 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add.'500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener. N All Y Other: N Other Description: Ecompasing. BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2580 Owner: Contractor: KEMMER RIDGE LLC CHAD E DAVIS CONSTRUCTION Required Items and Reports(Conditions) 12555 SW HALL BLVD 2808 19TH AVE 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97223 FOREST GROVE,OR 97116 PHONE: PHONE: 503-357-8587 FAX: Total Fees: $40,573.74 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is s ed for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Ce r. T ose r s rth in OAR 059_nn9_rtfl'In Ihrnunh 114t oc ..nn1 rinoo Vnu may nhfain a rn !fhn mlae nr rVireri nucefinne in nl ikW:ha Tallinn cn 0?9 1jl Issued By: ---� Permittee Signature: 03.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each Inspection. rr CITY OF TIGARD MASTER PERMIT ` It COMMUNITY DEVELOPMENT Permit#: MST2021-00371 Date Issued: 05/23/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S107AA17700 Jurisdiction: Tigard Site address: 14454 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 177 Project: Polygon at Roshak Ridge, Lot 177(2 of 2)ADUs Project Description: New attached ADU(2). NO FINAL INSP UNTIL DEFERRED SDCs PAID. BUILDING Floor Areas Required Setbacks Reauired Stories: 3 Bedrooms: 5 First: 1092 sf Basement: 33 sf Left: 3 Parking Spaces: 0 Height: 28 Bathrooms: 3 Second: 1138 sf Garage: 526 sf Front: 8 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors Total: 2263 sf Value: $324,270.62 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 3 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckfw Prevntr: 0 Footing Drain: 0 Ice Maker. 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feedera Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 WI Svc or Fdr: 0 Ea addt 500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v 0 1000+amp/volt: 0 ELECTRICAL•RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC. N Security Alarm: N Vaccuum System. N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU VB R-3 2263 Owner: Contractor: TAYLOR MORRISON NORTHWEST LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Fire Rated Conditions VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Ersn Cntrl 503-639-4175 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $20,730.27 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR acn_nM-onlrl lhrnunh nab g59-nn1Jingn VA,,mau nhlain a ennu of+ha ndae nr,lirart nuoefinne In rll inlet hit Tallinn FM 909 10R7 nr'I Ann'4'19 9144 Issued By: No{Lg VaA-DP,W€qte, Permittee Signature: O Ap-p- ca-i.o-vt, Call 503.639,4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. CITY OF TIGARD MASTER PERMIT :� a . COMMUNITY DEVELOPMENT Permit#: MST2021-00370 Date Issued: 05/23/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 2S107AA17700 Jurisdiction: Tigard Site address: 14452 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 177 Project: Polygon at Roshak Ridge, Lot 177(1 of 2)ADUs Project Description: New attached ADU(1). NO FINAL INSP UNTIL DEFERRED SDCs PAID. BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 4 First: 947 sf Basement: 64 sf Left: 3 Parking Spaces: 0 Height: 28 Bathrooms: 3 Second: 1007 sf Garage: 448 sf Front: 8 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Total: 2018 sf Value: $287,945.36 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: Storm Sewer: 100 0 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 0 Ice Maker. 1 Hose Bib: 1 Backwater Value: 1 Bckflw Prevntr. 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add,500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU Vt R-3 2018 Owner: Contractor: TAYLOR MORRISON NORTHWEST LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Fire Rated Conditions VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Ersn Cntrl 503-639-4175 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $19,938.78 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oco_nn1-0nin fhrn,nh now QF9-On1-nnfrl Vnn mov nhfain a rnnv of tha n.lac nr dirarf,l acenne M r111Nrt hw rallinn cO 7k7 1QR7 nr 1 Ann 11]'144 HoU.y Vag.De,Wegr, Issued By: Permlttee Signature: O in., Afrpt.L.c.49.4-Lan, Call 503.839.4175 by 7:00 a.m.for the next available inspection date. This penult card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob slte at the time of each inspection. CITY OF TIGARD MASTER PERMIT .q COMMUNITY DEVELOPMENT Permit*: MST2021-00369 Date Issued: 05/23/2022 T!GARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 2S107AA17700 Jurisdiction: Tigard Site address: 14450 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 177 Project: Polygon at Roshak Ridge, Lot 177 Primary dwelling&(2)ADUs Project Description: New detached dwelling with(2)attached ADUs. NO FINAL INSP UNTIL DEFERRED SDCs PAID. BUILDING Floor Areas Required Setbacks Reeuired Stones: 3 Bedrooms. 5 First. 1091 sf Basement: 33 sf Left: 3 Parking Spaces: 0 Height: 28 Bathrooms. 3 Second: 1184 sf Garage: 507 sf Front: 8 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Total: 2308 sf Value: $329,198.04 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 0 Drywall-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=10OK: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add?500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener. N All Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2308 Owner: Contractor: TAYLOR MORRISON NORTHWEST LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Fire Rated Conditions VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Ersn Cntrl 503-639-4175 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $24,301.75 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR Q50.nn1-nntn lhrnunh r1CR Q59-nMl10Qn Vn,i maw nhtain a rnnw of tha mine nr Airart nusatinne In rll IN(`hw ratlinn c(n 9't9 10119 nr 1 Ann CZ9 944A 1-1OU,9 Vaa.w De-Wege, Ow Ar-p-U.C.0-4-i-o-m.‘ Issued By: Permittee Signature: Call 503.639.417E by 7:00 a.m.for the next available inspection date. This permit card shall be kept In a conspicuous place on the job site until completion of the project. Approved plans are required on the iob site at the time of each inspection. _IN' CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permlt#: MST2021-00372 Date Issued: 05/19/2022 T I r;A R I7 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S107AA17800 Jurisdiction: Tigard Site address: 14480 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 178 Project: Polygon at Roshak Ridge, Lot 178 Primary Project Description: New detached dwelling with(2)attached ADUs. NO FINAL INSP UNTIL DEFERRED SDCs PAID. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 5 First: 971 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 26 Bathrooms: 4 Second: 1437 sf Garage: 477 sf Front: 8 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Total: 2408 sf Value: $338,897.20 Rear: 15 PLUMBING Sinks: 1 Water Closets: 4 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 6 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckltw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 7 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 Wl Svc or Fdr: 0 Ea add'I 500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo' N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2408 Owner: Contractor: TAYLOR MORRISON NORTHWEST LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Fire Rated Conditions VANCOUVER,WA 98680 VANCOUVER,WA 98660 2 Ersn Cntrl 503-639-4175 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $20,720.54 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire If work is not started within 180 days of Issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc ..nn1..n 11 n fhrn,inh rlAR QS9- 1-engf1 Vnn 'a„nhtain MI nf nslec nr direct ni melinne fn r1111JC by.=Ilinn Snq 979 10R7 nr 1 Rnn1'37/Vidd Issued By: /C y 1 � Permittee Signature: .-r/ /'eee-75 Call 503.639.4175 by 7:00 a.m.for the next available Inspection date. / This permit card shall be kept in a conspicuous place on the Job site until completion of the project. Approved plans are required on the job site at the time of each Inspection. CITY OF TIGARD MASTER PERMIT IIId COMMUNITY DEVELOPMENT Permit#: MST2021-00373 Date Issued: 05/19/2022 T f G A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S 107AA 17800 Jurisdiction: Tigard Site address: 14476 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 178 Project: Polygon at Roshak Ridge, Lot 178(1 of 2)ADUs Project Description: New attached ADU (1). NO FINAL INSP UNTIL DEFERRED SDCs PAID. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 672 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 26 Bathrooms: 3 Second: 953 sf Garage: 287 sf Front: 8 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Total: 1625 sf Value: $226,909.86 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heal Pump: N Hoods: 1 Other Units: 0 Furn<1o0K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc!Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 2 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU VB R-3 1625 Owner: Contractor: TAYLOR MORRISON NORTHWEST LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Fire Rated Conditions VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Ersn Cntrl 503-639-4175 PHONE PHONE: 360-695-7700 FAX: Total Fees: $14,812.02 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law equires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc _.nn1_nnin thrni in,-'AR O74c-nn0n nil mo„nhte' an nn , thn n!lac nr rllrnrr nmine}inne to ni INC h.,raulnn Sol 9 1057 nr'I nnn 1199�991A4 Issued By: I__ --Z-C G g/� Permittee Signature: c ��r'/✓ �k1?'47 V✓ Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the iob site at the time of each inspection. CITY OF TIGARD MASTER PERMIT 11 a COMMUNITY DEVELOPMENT Permit#: MST2021-00374 Date Issued: 05/23l2022 T6.GAAD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S107AA17800 Jurisdiction: Tigard Site address: 14478 SW 165TH AVE Subdivision: ROSHAK RIDGE Lot: 178 Project: Polygon at Roshak Ridge, Lot 178(2 of 2)ADUs Project Description: New attached ADU (2). NO FINAL INSP UNTIL DEFERRED SDCs PAID. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 720 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 26 Bathrooms: 3 Second: 1009 sf Garage: 398 sf Front: 8 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Total: 1729 at Value: $246,182.26 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 0 Other Fixtures: 0 Orywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 2 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less; 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O SvdFdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 801+amp-1000v: 0 1000+amp/vo1C 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW ADU VB R-3 1729 Owner: Contractor: TAYLOR MORRISON NORTHWEST LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Fire Rated Conditions VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 Ersn Cntrl 503-639-4175 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $15,177.66 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 160 days. ATTENTION' Oregon law re ires you t follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR ac..nnt_nnln thrrn inh n g7_nn1_n an V ma"nht ' a r ,nr the,ndoc nr riirart ell actinnc to nl INn by Tallinn CM 10R7 nr 1 Ann 111 9121d • Issued By: /j; '1 Permittee Signature: �r�pL/ ,Gl '�6/ Call 503.639,4175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept In a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. CITY OF TIGARD MASTER PERMIT 'rl s COMMUNITY DEVELOPMENT Permit#: MST2021-00531 Date Issued: 05/26/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S108AB01300 Jurisdiction: Tigard Site address: 15409 SW SILKWOOD CT Subdivision: BULL MOUNTAIN SUMMIT Lot: Project: Bull Mountain Summit, Lot 11 Project Description: New detached dwelling. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 940 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 31 Bathrooms: 3 Second: 1404 sf Garage: 486 sf Front: 15 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Total: 2344 sf Value: $331,001.60 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins; 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 1 Drywall-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O SVC/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2344 Owner: Contractor: KEMMER RIDGE LLC CHAD E DAVIS CONSTRUCTION Required Items and Reports(Conditions) 12555 SW HALL BLVD 2808 19TH AVE 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97223 FOREST GROVE,OR 97116 PHONE: PHONE: 503-357-8587 FAX: Total Fees: $39,387.71 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requ' s you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc7-nnlJlnln thrnnnh(1 omnt-nnon Vn, y nhtnin nny ha mlae nr dirt mmctinnc In ill'Nr:by Tallinn 6n1 717 10117 nr 1'Ann 117 921.1 Issued By: Permittee Signature: Z . /� ' Call 503.639.4175 by 7:00 a.m.for the next available inspection date. f This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. 1111 CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2021-00525 Date Issued: 05/25/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S108AB01300 Jurisdiction: Tigard Site address: 15382 SW SILKWOOD CT Subdivision: BULL MOUNTAIN SUMMIT Lot: Project: Bull Mountain Summit, Lot 3 Project Description: New detached dwelling. Demo credits from BUP2021-00055 applied for Transportation&Parks only. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 966 st Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 25 Bathrooms: 3 Second: 1383 sf Garage: 399 sf Front: 15 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Total: 2349 sf Value: $327,193.14 Rear. 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer. 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amplvolt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm. N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2349 Owner: Contractor: KEMMER RIDGE LLC CHAD E DAVIS CONSTRUCTION Required Items and Reports(Conditions) 12555 SW HALL BLVD 2808 19TH AVE 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97223 FOREST GROVE,OR 97116 PHONE PHONE: 503-357-8587 FAX: i Total Fees: $12,241.93 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR a49_nn1JIMn thm,inh AP oc9-n(1i inan Vnu mow nhfoin o rnnu of fho n dnc nr dirori all noe/inns fn rli INr`by ruliinn Rn4 wv?10R7 nrnr I grin T39 99dd Issued By: -I j J Permittee Signature: 549 rt F 1)t'C q Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. 1 IIIII CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2021-00526 T I c;AI<.[> 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/25/2022 Parcel: 2S108AB01400 Jurisdiction: Tigard Site address: 15330 SW SILKWOOD CT Subdivision: BULL MOUNTAIN SUMMIT Lot: Project: Bull Mountain Summit, Lot 4 Project Description: New detached dwelling. Demo credits applied from BUP2021-00056 for Transportation & Parks only. BUILDING Floor Areas Reauired Setbacks Required Stones: 2 Bedrooms: 4 First: 1085 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 24 Bathrooms: 3 Second: 1495 sf Garage: 686 sf Front: 15 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Total: 2580 sf Value: $372,074.48 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 1 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 Wl Svc or Fdr: 0 Ea add'I 500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc!Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio 8 Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2580 Owner: Contractor: KEMMER RIDGE LLC CHAD E DAVIS CONSTRUCTION Required Items and Reports(Conditions) 12555 SW HALL BLVD 2808 19TH AVE 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97224 FOREST GROVE,OR 97116 • PHONE: PHONE: 503-357-8587 FAX: Total Fees: $13,529.74 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR octon..-nnin+hrnnnh f1GA 059-nn1-nnon we.rem,nhtain a rnnv of tha n doe nr riirar+nnaetinne+n fN INC by nallinn cm 9g9 10a7 nr 1 eon 119 9144 • Issued By: "Y IR 7-11 l V L Permittee Signature: %Re_ C?13\I C-q h"1 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each Inspection. II CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit it: MST2021-00530 Date Issued: 05/25/2022 T f G A II.f t 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S108AB01300 Jurisdiction: Tigard Site address: 15391 SW SILKWOOD CT Subdivision: BULL MOUNTAIN SUMMIT Lot: Project: Bull Mountain Summit, Lot 10 Project Description: New detached dwelling. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 1053 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 23 Bathrooms: 3 Second: 1504 sf Garage: 514 sf Front: 15 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Total: 2557 sf Value: $360,250.98 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bekflw Prevntr: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc?Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdc 0 Ea add9 500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v 0 1000+amplvolt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2557 Owner: Contractor: KEMMER RIDGE LLC CHAD E DAVIS CONSTRUCTION Required Items and Reports(Conditions) 12555 SW HALL BLVD 2808 19TH AVE 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97223 FOREST GROVE,OR 97116 PHONE: PHONE: 503-357-8587 FAX: Total Fees: $40,289.62 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR Q ,..nr11-nnln fhrro,nh AP 0c911M-nno Vni, nhfain v rnnv of that ndate nr Aire t n„aefinne to ell INC by Tallinn AM 9A9 10A7 nr I Ann TV)9'i4el Issued By: 4 '" 1 et Permittee Signature: Tke2 t1 t /1CQ 41 a/ Call 503.639.4175 by 7:00 a.m.for the next available Inspection date. V This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2021-00529 Date Issued: 05/25/2022 T I i;;1 R D 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Parcel: 2S108AB01300 Jurisdiction: Tigard Site address: 15375 SW SILKWOOD CT Subdivision: BULL MOUNTAIN SUMMIT Lot: Project: Bull Mountain Summit, Lot 9 Project Description: New detached dwelling. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 1067 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 23 Bathrooms: 3 Second: 1459 sf Garage: 505 sf Front: 15 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Total: 2526 sf Value: $355,741.48 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea addl 500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener N All Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2526 Owner: Contractor: KEMMER RIDGE LLC CHAD E DAVIS CONSTRUCTION Required Items and Reports(Conditions) 12555 SW HALL BLVD 2808 19TH AVE 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97223 FOREST GROVE,OR 97116 PHONE: PHONE: 503-357-8587 FAX: Total Fees: $40,194.70 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR Q49-nni_niin Ihrroinh Al?QR911M-ring Vn,i me nh+ain a nnmi of+ha nilaa nr dirt nuaafinna+n rll 1NC ha nollinn aria 9A9 1QA7 nr i ftnn al9 94dd Issued By: CP"' / Permittee Signature: l jG AV"4".\ Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. CITY OF TIGARD MASTER PERMIT s COMMUNITY DEVELOPMENT Permit a: MST2021-00528 Date Issued: 05/25/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S108AB01400 Jurisdiction: Tigard Site address: 15349 SW SILKWOOD CT Subdivision: BULL MOUNTAIN SUMMIT Lot: Project: Bull Mountain Summit, Lot 8 Project Description: New detached dwelling. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 1053 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 23 Bathrooms: 3 Second: 1504 sf Garage: 514 sf Front: 15 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Total: 2557 sf Value: $360,250.98 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 1 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Tema Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr. 0 Ea add!500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2557 Owner: Contractor: KEMMER RIDGE LLC CHAD E DAVIS CONSTRUCTION Required Items and Reports(Conditions) 12555 SW HALL BLVD 2808 19TH AVE 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97224 FOREST GROVE,OR 97116 PHONE: PHONE: 503-357-8587 FAX: Total Fees: $40,289.62 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR cic9J1n1JNn fhm.,nh AP O57-nn1_MQ Vn„mot,nhfain o rnnv of 41-c n iln¢nr Airerl ni inctinn<In rN par by rnl[inn Am 9A9 1QA7 nr I Ann 11?71114 Issued By: !/VJfVlilAl✓l/l4 Permittee Signature: \i?—Q 11 C71 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. CITY OF TIGARD MASTER PERMIT III ' Permit#: MST2021-00527 ' COMMUNITY DEVELOPMENT T I G AR D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/25/2022 Parcel: 2S108AB01400 Jurisdiction: Tigard Site address: 15323 SW SILKWOOD CT Subdivision: BULL MOUNTAIN SUMMIT Lot: Project: Bull Mountain Summit, Lot 7 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stones: 2 Bedrooms: 4 First: 1067 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 23 Bathrooms: 3 Second: 1459 sf Garage: 505 sf Front: 15 Smoke Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Yes Total: 2526 sf Value: $355,741.48 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch CIrcuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr. 0 Ea add'I 500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other. N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2526 Owner: Contractor: KEMMER RIDGE LLC CHAD E DAVIS CONSTRUCTION Required Items and Reports(Conditions) 12555 SW HALL BLVD 2808 19TH AVE 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97224 FOREST GROVE,OR 97116 PHONE: PHONE: 503-357-8587 FAX: Total Fees: $40,194.70 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc9_rnn1_nnln rhrn,In AP oF9-nn1_nnon Vnu may nhlain a runs,of th>nilac nr r4irw-f ni inetinnc rn nu INr h.,-.air,,,cm 929 10 7,�n,.r4 Ann'IT)9Qdd ,r.Ul Issued By: ' Permittee Signature: c1l.,4 te_ 1 Cl Call 503.639.4175 by 7:00 a.m.for the next available inspection date. '1 This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD MASTER PERMIT ' 1 ' COMMUNITY DEVELOPMENT Permit#: MST2021-00417 Date Issued: 05/02/2022 TEGAR.D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel 2S107AA23200 Jurisdiction: Tigard Site address: 16774 SW ROCKHAMPTON LN Subdivision: ROSHAK RIDGE Lot: 232 Project: Polygon at Roshak Ridge Lot 232 Project Description: New detached dwelling. NO FINAL INSP UNTIL DEFERRED SDCs ARE PAID BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 5 First: 1107 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 26 Bathrooms: 3 Second: 1461 sf Garage: 400 sf Front: 12 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors Total: 2568 sf Value: $355,841.44 Rear: 10 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 1 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add9 500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing. BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2568 Owner: Contractor: TAYLOR MORRISON NORTHWEST LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 PHONE: PHONE: 360-695-7700 FAX: Total Fees: $25,710.13 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR QF9-nn1_nnln thrn,mn CAP QA9-nnl_nnon Yni, a nht in a rnrn,of the rulac nr rlirnrt nnactinnc to fill INC by Tallinn Aril 9'29 1QA7 nr 1 Ann 119 m5zt4 Issued By: 3�-LL. Permittee Signature: 40 all 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. e•w..z•..wuaHNatn#+#i uric##braY#f#59tUhMd6x#Kr#Iwu hw u udaio-t.sroaar rit.fa..xt xss.ia#iftde##.e u.aa:rsurait#t "i3$*h...nW#fN rR+:+.Ry:pyiet....... .want+,M»w.4ss uvaixezra to »issrasae tuf.tUtazt i4ast#fMatkW+i3ts?ebWa N.k A.e`+.•. daf4a4iwR.titaieMWtvutkii.w r•ers..... IPermn CITY OF TIGARD MASTER PERMIT , 2 COMMUNITY DEVELOPMENT it#: MST2021 00284 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/16/2022 Parcel: 2S107AA01300 Jurisdiction: Tigard Site address: 14379 SW 168TH AVE Subdivision: ROSHAK RIDGE Lot: 13 Project: Brahmbhatt Project Description: New 345 sq ft deck, half of deck will be over 30"above grade. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 12 Smoke Dwelling Units: 0 Third: 0 sf Right: 3 Detectors: Total: 0 sf Value: $42,248.70 Rear: 5 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add9 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: BRAHMBHATT,ASHISH NARENDRA MONTEZUMA CONSTRUCTION LLC Required Items and Reports(Conditions) BRAHMBHATT,AMITA ASHISH 18840 NW RACCOON LN OR KAUR GALES CREEK,OR 97117 14379 SW 168TH AVE TIGARD,OR 97224 PHONE: PHONE: 971-330-5104 FAX: Total Fees: $1,274.59 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law equires you o follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR QS2nn1_nnln thrni,nh(lA nn1_n II mnft nff of}ha nine nr dirnnt niinefinne to fll INC h,enllinn c,n1 9 1oMM77 r r 1 Rnn 119 9/4aa�!' es Issued By: - Permittee Signature: �"'L ! 1/�t'25 , Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. II CITY OF TIGARD BUILDING PERMIT COMMUNITY DEVELOPMENT Permit#: BUP2021-00099 TIG.A.R.D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 5/16/2022 Parcel: 1 S 135BD00100 Jurisdiction: Tigard Site address: 9600 SW OAK ST Project: T-Mobile Subdivision: ASHBROOK FARM Lot: 5 Project Description: Modify existing T-Mobil rooftop wireless telecommunication facility. Remove and replace(6)antennas&ancillary equipment,and(2)equipment cabinets. Contractor: KGPCO SERVICES LLC Owner: KING CAPITAL INVESTMENTS LLC 3305 HIGHWAY 60 ATTN KING, THOM WEST FARIBAULT, MN 55021 19250 NE PORTAL WAY PORTLAND, OR 97230 PHONE: 503-334-2268 PHONE: FAX: FEES Specifics: Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: VA Permit Fee-Additions,Alterations, 06/09/2021 $453.95 Occupancy Grp: U Occupancy Load: 0 Demolition 12%State Surcharge-Building 06/09/2021 $54.47 Dwelling Units: 0 Plan Review 04/28/2021 $295.07 Stories: 0 Height: 0 ft DC Provision Review, COM TI-Ping 06/09/2021 $103.00 Bedrooms: 0 Bathrooms: 0 Info Process/Archiving-Sm$0.50(up to 06/09/2021 $62.50 Value: $25,000 11x17) Hourly Building Rate 06/09/2021 $90 00 Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $1,058.99 Required: Required Items and Reports(Conditions) 1 Special Inspection(see plans) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obta T8rtne ia+ec.pr)direct questions to OUNC by calling 503.232.198 r 1.800.332.234 Issued By: • Signature: .639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. CITY OF TIGARD BUILDING PERMIT COMMUNITY DEVELOPMENT Permit#: BUP2021-00236 Date Issued: 5/12/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S102DB09600 Jurisdiction: Tigard Site address: 8803 SW OMARA ST Project: Tigard Senior Housing Subdivision: TIGARD SENIOR HOUSING Lot: 1 Project Description: A new 47,110 sq.ft.58-unit affordable housing apartment building. Contractor: WALSH CONSTRUCTION CO/OREGON Owner: TIGARD, CITY OF 2905 SW 1ST AVE 13125 SW HALL BLVD PORTLAND, OR 97201 TIGARD, OR 97223 PHONE: 503-222-4375 PHONE: FAX: 503-274-7676 Specifics: FEES Description Date Amount Type of Use: MF Class of Work: NEW Type of Const: VA Permit Fee-COM-New Construction 05/09/2022 $39,154.02 Occupancy Grp: R-2 Occupancy Load: 177 12%State Surcharge-Building 05/09/2022 $4,698.48 Plan Review 10/05/2021 $17,473.85 Dwelling Units: 58 DC Provision Review,COM New-Bldg 05/09/2022 $218.50 Stories: 4 Height: 42 ft DC Provision Review,COM New-Ping 05/09/2022 $218.50 Bedrooms: 58 Bathrooms: 61 Plan Review-Fire Life Safety 05/09/2022 $15,661.61 Value: $8,639,032 Info Process/Archiving-Lg$2.00(over 05/09/2022 $130.00 11x17) Info Process/Archiving-Sm$0.50(up to 05/12/2022 $61.50 Floor Areas: 11x17) Total Area: 47110 Plan Review 05/12/2022 $7,976.26 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $85,592.72 Required: Required Items and Reports(Conditions) 1 Special Inspection(see plans) Fire Sprinkler: Yes Parapet: No Fire Alarm: Yes Protected Corridors: No Smoke Detectors: Yes Manual Pull Stations: Yes Accessible Parking: 1 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232;,1982or 1.800.332.2344. Issued By: �� _ mittee Signature: ' Call 4175 by 7:00 a.m.for the next available inspection`date. 4-- -- This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection.