Plans (20) F PS2020 -0009 1 f - RAUG 1 ° �°z°Fire Alarm Plan - Aspen Capital Tenant ImprovementECEIVED cl�voF T, ARD BUILDING DIVISION 13190 SW 68th Parkway, Tigard, OR 97223 I - FIRE ALARM SYMBOLS / BACKBOX INFORMATION APPLICABLE BUILDING CODES SCOPE OF WORK 2014 OSSC w/STATE OF OREGON AMENDMENTS BUILDING DESCRIPTION: EXISTING 1ST FLOOR TENANT IMPROVEMENT SYMBOL QTY PART NO, MANUF, DESCRIPTION MOUNTING BOX INSTALLATION NOTES 2013 NFPA 72 AREA OF WORK BUILDING OCCUPANCY: B a SPRINKLERED: YES I APS6A EST AUXILIARY POWER SUPPLY SUPPLIED SURFACE MOUNT CAN TOP OF BOX SUGGESTED 72"A.F.F. U 2012 NFPA 70 PERFORMANCE CLASS: SLC / NAC B APS6A 2 DURA12-5F DURACELL 12V SAH SEALED LEAD ACID BATTERY a O SCOPE: CC IS 1 SIGA-CC1S EST ADDRESSABLE SYNCHRONIZATION OUTPUT MODULE RED 4-SQUARE DEEP BOX (BY INSTALLER) a MOUNT IN APS6A CAN PERFORMANCE SYSTEMS INTEGRATION LLC IS PROVIDING A FIRE ALARM SYSTEM CONSISTING OR CENTRAL STATION MONITORING CRH 6 SIGA-CRH EST ADDRESSABLE HIGH OUTPUT CONTROL RELAY MODULE RED 4-SQUARE DEEP BOX (BY INSTALLER) tn Tr •• NEW AUXILIARY POWER SUPPLY w/ BATTERY BACKUP g TRANSMISSION TYPE: PHONE LINE •• ADDRESSABLE DETECTORS AND MODULES u ,0 NOTIFICATION APPLIANCES (STROBES, HORN-STROBES) I SIGA-PD EST INTELLIGENT OPTICAL DETECTOR RED 4-SQUARE DEEP BOX (BY INSTALLER) CEILING MOUNT NOT LESS THAN 36"FROM HVAC OUTLETS, NOT LESS THAN 12" o COMMUNICATION TYPE: •• ® i L MONITORING COMPANY: TIE TO EXISTING FIRE ALARM SYSTEM 1 SIGH-SBI EST w/DETECTOR BASE FROM SPRINKLER HEADS OR NOT LESS THAN 12"FROM LIGHT FIXTURES EXISTING BY OWNER SUPPLIED BRIGHT ORANGE SHIPPING CONTAINER NOT TO BE USED AS A DUST COVER ° 4 ACCOUNT NUMBER: DO NOT INSTALL ANY DETECTOR PRIOR TO OPERATION v w `1"` PHONE NUMBER: p, N C CJ N 5?- 18 GC-HDVM EST CEILING HORN-STROBE RED 4-SQUARE DEEP BOX {BY INSTALLER) MOUNT WITHIN 30'OF FINISHED FLOORE cn FIRE ALARM SUBMITTAL REQUIREMENTS �LL 13 GC-VM EST CEILING STROBE RED 4-SQUARE DEEP BOX {BY INSTALLER) MOUNT WITHIN 30'OF FINISHED FLOOR Tn a EI 0 1. The work site address and work activity location w 2. Work site owner or tenant contact name, address, and telephone number a) a Q 3. Contractor or installer information, including state electrical license number w E I 4. Description of work 5. Three sets of scaled plans, not smaller than 11 x 17 inches. Your plans must include: _ l''''' "; -4-- 5.1. Floor plan indicating the use of all rooms OPERATIONS MATRIX o C 5.2. Riser Diagram SHEET INDEX _ 5.3. Location of all alarm-initiating devices - I- 2 < C 5.4. Location of all alarm notification devices, including candela ratings for visible devices OUTPUTS occ CC .I 5.5. Location of alarm control, transponders, and notification power supplies - .-- --- i I -- 5.6. Annunciationo. COVER SHEET FA-01 ; C----' 5.7. Power connection 5.8. Battery calculations RISER DIAGRAM / CALCULATIONS FA-02 L� 5.9. Voltage dropcalculations - - �_ o �� � 5.10. Volt gt es and sizes CC Z a 1 gl •� 3 Wiring types INSTALLATION FA-03 o to 74; E N 5.1 1. Manufacturer's data sheets with model numbers and information for equipment, devices, and ---_.---- materials Ln g 0U WIRING FA-04 w z r .o 5.12. Ceiling height and construction details z Z Ll! — 5.13. Interface of fire safetycontrol functions ¢ z CC I- a Q Q) 0 FIRST FLOOR AREA OF WORK FA-05 a FIRE ALARM DEVICE LAYOUTi:i W • - z Q Lu ¢ � 3- �` •I_ (- ) — O J a ¢ co "': LLQ ^co i= _._ u ¢ Q `',:21 T� WIRE SCHEDULE ce ,_ _ ICI 5D — _ CABLE TYPE A BCDE FHPX - - oe LLJ 12 AWG PAIR • ' Ir z t �x__ a o +Q c4 z �O P.Ft_,2p Ec, 14 AWG PAIR • • • ¢ ¢ z ¢ ¢ _� ¢ ¢ Oe) � � y 'C� � DRAWN BY 16 AWG PAIR J J ¢ � � � � i � •. • N0- � F- ..-' j '' / JM - .� a �� '28 AWG PAIR • • • o o ¢ z HN IFPLR OR FPLP(AS REQUIRED) z z z u DoCz - O zi j , MARCix OHETTE r CHECKED BY 0 O ¢ LEA No 3T323I.22 SHIELDED • z z WET NO.112223 TWISTED • o 0 ¢ FIRE ALARM De = ' `� SYSTEA95 / • v7 U: 4: Q I— V, ._—..�'J ,' RATED FOR UNDERGROUND AND WET CONDITIONS(AS REQUIRED) VICINITY MAP "' f ‘Ni CABLE USE EXISTING FACP AC POWER LOSS ' ' `.- cxr jE2�24 i EXISTING FACP BATEERYPOWER LOSS • • • F REV. TITLE DATE ;SIGNAL LINE CIRCUIT (SLC) • _ APS6A SUPPLY AC POWER LOSS • • • 0 15T5UBMITTAL 6/25/2020 CONVENTIONAL INITIATING DEVICE CIRCUIT (IDC) APS6A SUPPLY BAIIERYPOWER LOSS • • • ZONE INPUT • RELAY OUTPUT • '`E`='T, "` ' "' `'g'"' FIRE Al ARM SYSTEM OPEN CIRCUIT • . • - 1=t3We'S Home .� Q A KCREEK FIRE ALARM SYSTEM GROUND FAULT s . • - NOTIFICATION APPLIANCE CIRCUIT (NAC) • (tFTto1`GICT# fltFIRE ALARM SYSTEM TROUBLE • • • I REMOTE ANNUNCIATOR 24VDC POWER • Geof Fox Uf wtr y ,, ,, I r,• z REMOTE ANNUNCIATOR RS485 DATA • 9P�1illll131 Y t`�] 47 FF��� ��� P. 6 GENERAL SMOKE DETECTOR • • • • AUDIO RISER • Art S1IC Auto Body, `s $ rs SPEAKER CIRCUIT • f '"i g 1 CITY OF TTGATtP.,. "` ; EXISTING ALARM DEVICE{NOTSHOWN) • • • • REVIEWED FOR E UD COMit'LIANCE DOOR HOLDER CIRCUIT rte,, 4 g4.04,4„,,,,, ;: - 4.tF EXISTING SUPERVISORY DEVICE (NOTSHOWN) • • • AUXILIARY 24VDC POWER W `' qi° t Portland Oregon TempleAp�rn�c NOTE: RS232-18AWG PAIR/TWISTED, SHIELDED WESTLAKE OTC: I I REVISIONS NON-POWER LIMITED CIRCUITS CAN NEVER SHARE PATHWAYS WITH POWER LIMITED CIRCUITS Pcr�nit #: +6 Address: _ : 'JG�.ry PLOT DATE Y ilk -4." Stiitc#• Cgrtnl9 : 71-f 4. :_ 4 )An--5). , :ate: 6/25/2020 13190 SW 68th Pkwy , Tigard,OR 97223 C hiprllxfliril PROJECT NUMBER ��° 02020- 9, 109324 N W4PERMIT NUMBER ASBUILT NOTE TO INSTALLING CONTRACTOR TBD S __ . INSTALLING ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SINGLE ACCURATE AND LEGIBLE REDLINED DRAWING SET. DRAWINGS SHALL BE REDLINED AS NECESSARY TO SHOW THE FOLLOWING: • DEVICE AND PANEL LOCATIONS, ADDITIONS, DELETIONS AND — ADDRESSES OR BAR CODES THE INFORMATION ON THIS DRAWING • CIRCUIT NUMBERS IS THE ORIGINAL, UNPUBLESHED WORK OF PERFORMANCE SYSTEMS • WIRE AND CONDUIT ROUTING INTEGRATION LLC. • WIRE FILL USING WIRE CODE FROM LEGEND ON SHOP DISCLOSURE, REPRODUCTION, OR USE DRAWINGS WITHOUT THE PRIOR WRITTEN CONSENT OF PERFORMANCE SYSTEHS • EOL RESISTOR LOCATIONS AND VALUES INTEGRATION LLC IS PROHIBITED PERFORMANCE SYSTEMS INTEGRATION WILL INCORPORATE ALL REDLINED SHEET TITLE CHANGES INTO THE RECORD AUTOCAD SET OF DRAWINGS FOLLOWING THE RECEIPT OF THE DRAWING SET. COVER SHEET - FIRE ALARM N/A z Cv x SHEET co Ili FA-Ol E U Q WIRE SCHEDULE PLAN SYMBOLS ch CABLE TYPE ABCDEPHPX W �a `41 12 AWG PAIR I • Ci 114 AWG PAIR • —A SYMBOL DESCRIPTION • . o 16 AWG PAIR • • a 18 AWG PAIR • • • 4 APS6A 1 2 3 4 5 6 7 8 9 Q1 IFPLR OR FPLP(AS REQUIRED} C)('- � 3OCD S11, ,S 30CD r, ( 95CD 0,,ISKOHM EOLR) AUXILIARY POWER SUPPLY `2 O® NAC1 \B (TV-) v15CD ` 30CD v;75CD �15CD15CD " 15CD APS6A 12V 5AH SEALED LEAD ACID BATTERY SHIELDED • O NAC2 TWISTED • " - TO EXISTING SLC © CRH -NAC3 ® CC1S ADDRESSABLE SYNCHRONIZATION OUTPUT MODULE RATED FOR UNDERGROUND AND WET CONDITIONS(AS REQUIRED) ° STROBE SYNC CIRCUIT , A`- ,CCS}' -NAC4 1 2 3 4 5 6 7 ._ 1 M (NOT SHOWN) 95CD (� 3oCD ?95CD ( 95CD (595CD SIGNAL LINE CIRCUIT(SLC) _ • E \B (TYN `"75CD (.9 6675CD T �T �T <15K OHM EOLR> CRH ADDRESSABLE HIGH OUTPUT CONTROL RELAY MODULE CONVENTIONAL INITIATING DEVICE CIRCUIT(IDC) •ZONE INPUT • Co w ® INTELLIGENT OPTICAL SMOKE DETECTOR -._. .....0 - — . c RELAY OUTPUT _ I • n 1 2 3 4 5 6 7 8 w/DETECTOR BASE NOTIFICATION APPLIANCE CIRCUIT(NAC) • U `. 30CD !�)_30CD (� � , ,30CD O, �,<_15KOHM EOLR) •REMOTE ANNUNCIATOR 221VDC POWER • 4_ E 16 O (TYP.) l � T 75CD \---1.1. 75CD 75CD 5CD 5CD IN- CEILING HORN-STROBE • n, REMOTE ANNUNCIATOR R5485 DATA • . ")' W 4., o ® (AUDIO RISER _ STROBE di 1 2 3 4 5 6 �_,;- CEILING 'SPEAKER CIRCUIT • Q 30CDry, :95CD ( �15KOHMEOLRy IDOOR HOLDER CIRCUIT • °. L— (TYP.) `-' 15CD v�3C1CD (530CD C= vi30CD 'AUXILIARY 21VDC POWER • .h 6 ' 11 o {Sy U E CD NOTE:RS232 -18AWG PAIR/TWISTED,SHIELDED ,11 NON-POWER LIMITED CIRCUITS CAN NEVER SHARE PATHWAYS WITH POWER LIMITED CIRCUITS ILLI v -I— C toy 0 2 1-SHEET NOTES; RISER DIAGRAM - FIRE ALARM < cc 7.1:i CD Ont U1.1.1 120VAC MAIN POWER (BY OTHERS) FOR THE FIRE ALARM SYSTEM. THIS SYSTEM REQUIRES A DEDICATED O Q CIRCUIT THAT IS LABELED"FIRE ALARM CIRCUIT'AND IS ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL. MI— ,� F- O� O CIRCUIT BREAKER LOCATION(S) SHALL BE PERMANENTLY NOTED AT ALL FIRE ALARM PANELS CC — P'* E Q O cn O LOCATE FIRE ALARM EQUIPMENT IN ELECTRICAL ROOM. FIELD VERIFY LOCATION, CD _ 85 a O. ROOM DESCRIPTION NOT SUPPLED. NOTIFICATION REQUIRED IF NORMALLY OCCUPIED BY MORE THAN ONE 1.1.1 i 0 OCCUPANT-COORDINATE WITH PSI. CC ~ 3 �I' c�i� 1111 C) rn W a O ci 0. e TIE REQUIRED BUILDING SYSTEM(S) TO SUPPLIED SIGA-CRH-COORDINATE WITH PSI. 7- N i N — O EXAMPLE: DOOR HOLDERS, FSD ACTUATION, HVAC INTERFACE.., CO R l 1 Q 1 EC DRAWN BY JM CHECKED BY (REV. TITLE DATE 0 1ST SUBMITTAL 6/25/2020 I APS6A FIAC POWER SUPPLY LOADING WORKSHEET GC-WWI GC-VM I 1 Qty. Source Desvlpton Stbyeach AIM each Standbyl Aiarm I 15 30 75 95 15 3U 75 95 1 APS6A AUXILIARY POWER SUPPLY 0.070 0.270 0.070 0.170 APS6A Description TOTAL NAC/AUX-1 NAC1 0.955 NAC/AUX-1 NAC1 2 1 1 4 1 955 NAC/AUX2 NAC2 1.291 NAC/AUX-2 NAC2 1 4 1 1 1291 NAC/AUX3 NAC3 1.136 NAC/AUX-3 NAC3 4 2 3 1136 NAC/AUX 4 NAC4 0.707 NAC/AUX-4 NAC4 4 1 1 707 REVISIONS De TOTAL 0.07Q 4 359 "`A "Ce 59 GI-WA T5c-a EffIc+ency Focior 1.2 1.2 82 G1-VM3=0 152 GI-vro7.5c PLOTDATE 171 = '' lraca 6/25/2020 24 Standby Hour Regui►ed Ah RegUred fog Stby 2.016 .sc - _ -: ,, 1.56.61 5 Alcxrrl Mnutes Required Ah Required fox Alm 0.436 =_ 155 Total Ah required fo cabinet 2.452 212 Battery CapacitySuppcied (2)5Ah 205 757-5A+T PROJECT NUMBER 85 GI-CVM 15cc 105 GI-C' M 30co. 109324 174 GT-G 1M 75CFf SYSTEM CALCLLAT1ONS-VOLTAGE DROP 214 G1-CwMII0o *Crkt - 70 C4CI5-7A 15;75,: RAS#OriCe 65 GO-WA 15C (rets Tata; 7 OC-VM a 153 GC-W,%7SCc ESTIMATED conductor 174 01✓-WA-n.0 PERMIT NUMBER DISTANCE OF 14 Fl OMNAL length,DISTANCE AWG PAIR START CLRRENT of pair X 2 DROP VOLTAGE END APS6A Desc.rat:n ,FEET) (VOLTAGES ;ANDS! _ (OHM) (VOLTAGE) DROP(%i (VOLTAGE) TBD NAC/AUX 1 NAC1 175 20.4 0.955 1.OT 1.026 5.0% 19.37 NAC/AUX-2 NAC2 175 20.4 1.291 1.W 1.387 6.8% 19.01 NAC/AUX-3 NAC3 2)0 20.4 1.136 1.23 1.395 6.8% 19.00 NAC/AUX-4 NAC4 150 20.4 0.707 0.92 0.651 3.2% 19.75 THE iNFORMAIION ON THIS DRAWING INotffcal:on Devsces are'ate-d to operate between 16-33 VDC OF THE ORORIM1NCE. UNPUBLISHED WORK PERFORMANCE SYSTEMS INTEGRATION LLC. 3.07 I o hm per 1 lc FT DISCLOSURE, kEPRODIJCTIpN, OR USE VITHEW T THE PRIOR 'WRITTEN 14 AWG copper uncoated CONSENT OF PERFORMANCE SYSTEMS Direct-Current Resistance at 167 deg F per conductor-NEC Conductor Properties Table INTEGRATION LLC IS PROHIBITED Installing Contractor is responsib4e fox fno;deter rm:nat on of requ ed was gauge based on actual site condtions and wlre used SHEET TITLE RISER DIAGRAM / CALCULATIONS CALCULATIONS - FIRE ALARM N/A z {NJ X SHEET � LU FA-02 k 0 U 12 Q Heat detector spacing — sloped ceiling Heat detector spacing --- peaked ceiling 0 =Heat detector i I I () =Heat detector 1 I` 1 I Anywhere .„-- _,, 1 in this area �,� I I / 1(t ("I rn)1 3 ft (1 ) " !' j 0 1 1 I 0 I 0 �� 'Y 1 1 I I ; w ! 1 I I I I I d 1 1 1 I f I I I /) 1 1 1 i 1 I 1 I a 1 1 1 I I I( l ! )-4 I 1 1 1 I 1/2S= S =50 R. 5=50ft. 1125= 25 ft. (8 rn) (15 m) (15 m) 25 ft(S rrt) 1 1 1 I I 1/2S= I S=50 ft_ I S=50 A. I S=5o R. 1 S =5011. 13 ft.(1 m) Rooms with peaked ceilings must have the first row of detectors placed within 3 o -: 25 ft. (8m) (15m) (15m) (15m) (15 m) max. ft.it mi(measured horizontally)of the ceiling peak.Additional detectors must be spaced based upon the horizontal projection of the ceiling and ceiling a o construction. '. t DETECTOR •- Rooms with shed ceilings having a slope greater than t R.In B ft.(1 min 8 m) u w must have the first row of detectors within 3-ft.(1 rn y of the high end of the (OF ALWAYS WITHIN HEAT DETECTOR MOUNTING (OF ANY SIDEWALL15)Ft, -�.-.- ) gl c ceiling.Additional detectors.if required,shall be spaced based upon the horizontal projection of the ceiling and telling construction t=ar roots having a `; slope less than 30 degrees,horizontal spacing must be adjusted according to the height of the peak. For roofs having a slope greater than 30 degrees,horizontal ti rn spacing snail tie adjusted according to the average sloped caking height. w h 13 O h 1-- 0 MINIMUM MINIMUM MINIMUM MINIMUM 36 in. + 36 in. 36 IN. - 36 IN. c y CEILING CEILING CEILING q + # 4 + # T 4 + # # + f ♦ + + + + # + i • t + + # # + i t + + /fir/ I� # f i T t + + + # i # # T + li CENT ZifACCEPTABLE HERE J ) �/ ACCEPTABLE HERE FLOURFSUTTURE LIGHT N. ACCEPTABLE HERE .9 C NEVER HERE NEVER HERE NEVER HERE NEVER HERE a AIR SUPPLY DIFFUSER 1- Ldp 0 2 1 p�ctt TOP OF DETECTORict CC W ACCEPTABLE HERE CDc• ~ 121N. Ili MAXIMUM M 8 c) 0 ,.... 1.L • Ev0N 0 (NOT TO SCALE) ,r /1�� W C ...0 _ CC M-- 3 Q WO � U' * N Qi -2 SMOKE DETECTOR MOUNTING SIDEWALL """� cn u_ crQ 1 j EC DRAWN BY JM CHECKED BY REV. TITLE DATE ro 15T SUBMITTAL 6/25/2020 STROBE (GC-SERIES} li♦ l Strobe Requirements for Sleeping Area In sleeping areas, where the mounting height is within 24 in. or fess of the REVISIONS NOT WITHIN 6 IN OF CEILING ceiling, the required intensity is 177 cd,.When the distance would be more than 24 in. to the ceiling, light intensities of 110 cd may be provided (see Figure 4) PLOT DATE b IN ▪ • 6/25/2020 •• • •• •a •+ Distance trorn Ceiling to Center of Lens Intensity Greater than or equal to 24 in. (610 mm) 110 Gd STROBE(G4/G1-SERIES) Eels than 24 in. (610 mm) 177 cd` PROJECT NUMBER FIRE ALARM CONTROL PANEL or FIRE ALARM REMOTE ANNUNCIATOR (SEE MANUFACTURER'S SPECIFICATION SHEET) A 109324 TOP OF CONTROL DISPLAY NOT TO EXCEED 60 IN A.F.F. TOP OF NAC POWER SUPPLY ttltgr►31" REF.ADA ` 'o PERMIT NUMBER 17 60 IN MANUAL PULL STATION 30 FT MAX Iwo_ TBD BOTTOM OF ANY CONTROL DISPLAY NOT BELOW 36 IN A.F.F. -- 8D-9b IN REF.ADA iiTOP OF BOX SUGGESTED MAX. 72 IN 1611111- . . .. Ffgure 4 MIN.3-1/2 FT.-MAX.4 FT. 36 IN 'NOTE 160 the room is larger thart 16 ...} 16 tt ,, the appliance shall be lac WW1 THE INFORNArION ON THIS DRAWING within ft,of the pillow measured horizontally. IOF S THE ORIGINAL, UNPUBLISHED WORK �" P4TEGRATOIONANLC SYSTEMS DISCLOSURE, REPRODUCTION, OR USC _.._.r-__ _ .........,,__.,.. �� WITHOUT THE PRIOR WRITTEN I y CONSENT OF PERFORMANCE SYSTEMS - _. ___�.,_�..---- _....... _..._..---'--"---.__....................... ----- .._......... ... .............. ..---- INTEGRATION LLC IS PROHIBITED. FLOOR OPERATING HANDLE TO FLOOR TOP OF DEVICE TO FLOOR LENS TO FLOOR LENS TO FLOOR MOUNT IN ACCESSIBLE LOCATION SHEET TITLE INSTALLATION ELEVATION NOTES: INSTALLATION -- ELEVATION THIS DETAIL IS NOT DRAWN TO SCALE. SOME DEVICES SHOWN MAY NOT EXIST IN PLAN. N/A SEE SPECIFIC DEVICE INSTALLATION SHEETS FOR MOUNTING HEIGHT OF BACK BOX. THE BOTTOM OR TOP OF INSTALLED Z DEVICE MAY NOT CORRESPOND TO INSTALLED BOX. ICV X SHEET co W FA-03 0 U I2 Q . APS6A Cabinet Layout Is—0l 1 En sure:Houses the electro and two standby w e = c�°'W n t. 6 batteries. .a I m- -. ---- r n n �, — u 2 Heat sink:Distributes heat away from the circuit board r,--z, r -°. •-----r% r3 Circuit board_Provides connections for aft circuits e Q o € 4 Tanswitch standoffs'3-TAMP rnount r>J standoffs o € le ,. i# 5 Jumper JP3_Ground Mutt enable or disable option a �— — — 6 AC LED:AC power on < r 7 _ - 7 llrtotantil g brackets:Option modulo mounting brackets 8 Jumpers JP1 and JP2:Mass A cc Crass B NAC option - L - 11 9 D P switches: tw o eight-position DIPswitches used z ..... r _� /1-----,N _ J - e- , for confjuratan ----' r--_• � --- h. j 10 Circuit LEDs:NAC,kettrsry,and wand fault train tg r- .01. r.c r -'a r• 'a t 144 LEDs U a- t• t..---11 r" .•. t' ; _ 2 -_ s`i I / N 45.—.4 tea 40171 1 C fl- 11 Batteries:Up to two 12 V 24 Aft batteries fit in the P1 4 � t" '_ �J , enclosure Forlarger batteries,use an external batterytua nn\� ` !:.:.. iQ W ..„.. ... cabinet for 8G 2), . 9 0 12 Jumper...1.P4:Bcharging attery jumper- u o r1-1 N t :. ti:::. Li • • 13 Option module{SIGA-REL..SIGA-U-106/Ree,Sid A- > MP2L4 and MN-I3I KT3 mounting area 0 11 14 Remote LED wiring harness connection a. [ !I _ ¢15 Remote IED Indicates AC power is on o Q SIGA-CC 1 S SIGA-SB / SB-4 Q_ .a.,, c Trouble relaywiringwith four AUX circuits } 0 Typical Wiring � �.” � � When A four NAC'AUX circuits are configured as AUX ckcuits and < C NAC Class S wiring . DIP switch SW2-6 is ON.a SIGA-CT2 module must be used tri cc N I-- --I' a single NAC circuit to one NAC output.Terminate the monitor the sense 1 trouble contacts and the trouble relay. < cc a --I Na,:._,:, _,4..;.,,..::,r_i-c.,,:.a,,4�cy Typical W I I"ll�g C— nitCuit with a 15 k Ohm EOL rE3SL910r. LU o NAC1l+ ' UL listedO DS The detector mounting bases accept #18 AWG (0.75rnm ), #16 }_ >-- To t AUX t EOL 15 ktl o NACU + Nf�CZ!+' (1.0mrn2), #14 AWG (1.5mm2), and #12 AWG (2.5mmm)wire sizes. o 0—•Q Notification AppilaB-ce Circuit(NAC) To auxiliary device Notification appliance rant(NAC) TB,... AUX1 - r a AUX2 + • i EOL CUL listed NAC2! +It NAC31+ • UL luted Note: Sizes #16 AWG (1.0mm)) and ##18 AWG (0.75mm2)are '�. E �, NAc1 ©� f To auxiliary device r t �fTIT3] Aux2 _ AUX3 am EOL to ul r) Ell b c„ w4c2+ Naar + a NAC4/' _ preferred far ease of installation. See Signature Loop Controller x L(, tv Typical of to four NAGS AU% :� To auxiliary device c0 cr. ,�Acars AUxa + catalog sheet for detailed wiring requirement specifications. C ce rj,� n To auxiliary device 20D inAAUx { + AUxa - .s Continuous e4 - F•— ci Q Q) O NAC4_ zoo ma AUX g IN c;. + ,.. Input from srgndlirYJ�ci4. Continuous Ga ova AI X‘,,,A This is 8 Control circuit: IN 61$- Sense 1 CUMQtJT;.r* I Standard Detector Base, SIGA-SB, SIGA-S84 a , LLQ _ o Carinuncrs m. -'1 + t�tl4Cs are not parmiltecl. �+ Sense 1 coM r*i,.• tN ,� ` s C/] +— IN f' i aur - Sen 2 CUM E« 47 ka _ �ev This is the basic mounting base Remote LED I Sense 1 con t-. ' _ OUT IN I.D,�.q� =GCt(S)moea for Edwards Signature Series de- OUT(„i.._,..1 =r To next booster or Control Circuit i IN + Sense 2 CUM ; NO r a Sense 2 COM 1h 1 �#INIAC anti of line Scxarce Out \ • trouts* COM '� r a ° °;% ' MaxMa per wit resistance lectors. The SIGA-LED Remoteper OUT V. r €stor NO i 0 _0 i t_._� + NC l must not exceed rte . 7c, Trouble COM .� Tei LED is supported by the Stan- _____ 10 Ohms Trouble COn ICs E°" EDC E EOL 47 kOhm �'�` Data u,irc>m i t7atdout to dard Base. > EC NC iv 13.1 AG power fail 16t + evi�ux dmriru TcNnt n /� +, Dote in from next device Description DRAWN B Y t� •. Dista out to or Signature 1 Um Used rrl<xlitotiiiy previous device sir i ' next devicecontroller ", rt" Signature controller 2 DxATA MUT t+, r ,„ 3 Not Used rr+1 i I M NAC wiring notes: `1 DATA iN].1 1. A trocrhte can the APS iC r d1 ern the existing control gar its NAG circuit canis a NAC trouble on that pene6.This S Renapte LED f) DATA IN I-i ` DATA OUT t l CHECKED B Y removes the noes to&eperraidty monitor the trouble contact except for AC power hurt(see]3]below). 7 Not Used fiotrT Remote LED(*) —•-• • In an altar m c ccrditirci.Vie APS adow$NAG currisrrt to nr downstream to devices cortriact l to the exietit'rJ control f s NAC cirCutt. S DATA M t,] CA IN f+l DATA OUT l+) From Signatare ntroller To Next Device 2. Beater to the connected control panel's&cementation for more details on NAC wiring, of Previous Device 131 The AC power fire para connection anriiiricsateei.at It re panel but dues rxat repair off prviliseS,fps a paxieterYniried time period in u.S_tire applications. 'REV. TITLE DATE 10 1ST SUBMITTAL 6/25/2020 G1 /GC - SERIES SIGA-CRH Wiring W Int ori (1) Signaling line circuit (SLC) from previous device Field wiring terminals accommodate 018 to #12 AWG (0.75 mm2 REVISIONS to 2.5 mm2)wiring. Horns,strobes, and combination horn-strobes . (2) Signaling line circuit (SLC) to next device are interconnected with a single pair of wires as shown below. (3) Power-limited and supervised PLOT DATE 04 ' (1)— + 0 0 0 (4) Normally closed contact (NC) 6/25/2020 + 1 + rl xt 0 .:. _ [ ----- (5) Common contact (C) • e' Iii — (6) Normally open contact (NO) poi, .Iv moan in en ot-kne 3 NC2 i (4) alarmcandgtron CP:ri ®4 #�f�� orraontroito C. >_ ) .-- ' 1 (5) —( ) (7) Relay terminal set 2. room S PROJECT NUMBER equipment 1 .� , c2 Z lid I - Cit- 4 - •• Not supervised. Power-limited unless connected to a nonpowerlimited 109324 I NO2 (6) — source. If the source is nonpower limited, eliminate the power-limited Note:Suchesmusi have oantinuous voltage. I II 1 NA 9 (4) mark and maintain a minimum of 0.25 in. (6.4 mm) space from c1 . (5) -(8) power-limited wiring, For other mounting methods, see enclosure and No (6) bracket installation sheets to maintain separation of power-limited and - V)11 nonpower-limited— wirin . The wire size must be capable PERMIT NUMBER 0 apab l' of handling 0 � 0--11 fault current from a nonpower-limited source. TBD (2) 06)0 — or Use type FPL, FPLR, FPLP, or permitted substitute cables, provided • • these power-limited cable conductors extending beyond the jacket are separated by a minimum of 0.25 in. (6.4 mm) space or by THE INFORMATION ON THIS DRAWING a nonconductive sleeve or nonconductive barrier from all other IS THE ORIGINAL, UNPUBLISHED WORK OF PERFORMANCE SYSTEMS conductors. Refer to the NFPA 70 National Electrical Code for more INTEGRATION LLC. DISCLOSURE, REPRODUCTION, OR USE details. WITHOUT THE PRIOR WRITTEN CONSENT GF PERFORMANCE SYSTEMS INTEGRATION LLC IS PROHIBITED. (8) Relay terminal set 1 . Identical to (7). SHEET TITLE WIRING N/A z v tv x SHEET cn w FA-04 0 0 cL r ' = �I LJ 3 J I. IN\ ( Q -� a s ill� e ! , rriv , )1 nix <›../ `. NAC3 a ` I_w r 47.25X - '+ - M -'70>c ' '_ ii x 0 ,, 15K a M s°l 8 l f--..._:_____, • J' n `� � `o-. �s 30CD IC) ^i rn I r3 m r* iTi Y f z r z B : , ; r, to a d ;0II co o c) U, 4 1scD 4CI I 1 •�•1; cQp ® ,C E 7 F�1 PI {``� ,� r ,� _ 4sx} C O .'.i �1 1 al T, Ca" VNF.RM. 7 1 1 .-------155--------47 4 r T�'11�� 1} T SK N �G X CS a x �c q IL -ry '- � _— s-- 7SCQ '/1 CC[NF.R k4. "i 5D ��--A' —._.J .-.__ Q0 Ci G A C 1 -11‘-t, , ( 1 75CD I ±itSe jj cL.I C:t)1'V1="_. M. ?45i� E ! I\'''''..> ,, , ,. ,.FFD4, , r iii IN } ; r - rx — S j • I / • 1 bn z- — 1` �I E r &G 'Z' f • 1 - :-'- 36 �._._ C Xt_ I I FIXED rJ z4� Q3X13 IG.3Xid 03 8 3 75C❑ •I SCD T� c.k .- ---_:ro _. . . __,._,. .. ✓.t 1 b-Y 1 I Y 1 •✓n.......,,..v..� ....TS.. _._._.- __.— n f X�,.-•._- S0.]FC_ Zi v i..v \ ' -Tt �� 4-.___ ' — - cp 6 PI ixQ try C7 rn b�fi I 47 5 FIXED I \�� F{xFi3 full 5l 1 x �[r. �A'�• I „ ,�. L_ __. i.__ b C3 . .�C:Q 1 3DCQ `I t /«�I 4 k 110 tau b -}• �In X �3rT x An 3 ..1XEt3pl 1XEp 33 _43 37 F4 � 3 2 F _ .. , �� ` 0 0 1.4 II 'Yt _ ��--J x r X .r }�i [ : \ I i� r. i it. .. r V :95Ce' 111 g0 Ski ► '�i i i __ _ o o : I I �-�,�.�% B N ,.... , t 1 I i V.4 0,N%WA I I IV,0 MN I.,' c„.,,..„ :r- --M5CD 6; : ---f-=E1) n „..1 _,, __,. i:/L,_,J L..„.i :1;gefr y ! I \ , .._ , .i. ,.. - ,,.,,a_s_ :0 FIXED, r1 ED LI' 11 FIXED ca i 0 0 11 _ ',onto 7r 12' iAI 0� _ q , i �: A _ �c �c 1 i I �!30CD 6 I � 63 r— 7 1$0 -- n 1 {X60 LA ( ll Fl]tE{ Vii fi. Ov I LJ i __ 1 _ W=„ -- L B ---- -- -=-d# � 2 : _ Q �; U ,_..f1 z z ( 1 4 IL '' j ��75CD B •T 1 1 1 ( 3 65 66 {�- i t39.._I. r _.82 rn � i•O 7 95CD B ter_ .___J ! w r3c13. sa s . A _,- NAC 3 AT APS6A 1 t ,:� 1 / •. SCD NAC4 AT APS6A` B �` , 4 3OCD 1......i _ J; G _,,.1 f \ 1 x*C� - o °i .aW7.:i t��'�7 € i -69 .."',.==d, ��70 it - y;�_ :.::ml f55 ami vii (I) I' Art - 3 si «€ { 1i CAT ,� i i,. �30CD a° O # No j `� � ✓ OOM? -. ` .1 © i f J 7. v �_ __. (ISK OHM EON) QI 0.1 I i. f - i i -'1:'--1 NAC4 S li 5 I its r �,©• A €28 APS6A I Ems:V j C� ' , _ -41'75- -_ �' 2 fW u €'" • EXISTING DETECTORE l ! °' CI.I) 9 I I I 1 , -__ I6\ ;! _ ® A CC15 5 I ....._. . ...� TO REMAIN • F . ` 3t If � f n j I, i p E 4�.... - � 1y ) 1 n A PiAC1 AT Aa76A ;. f __-. __� @� I -r\ iir �_-._. 24X56 } 24X8 ? '24X54 2048(.4) I 1 _ e AJ. }3 ADJ. 332 131 AJ, 1301 FILLS ( FC €_ E 7fi I , \:\ 0 57 I n •� r- T ..:=tel s€ e B -_ • y t ) i --1 TO EilialtiWINOW i Y _ - -riZi 77 L7 . O i.,,,-, t ` 4 14141 r4 I• 95CD FILES 15GDr ) f i --. . Lt1� W--.. O n.-......., i -r"-I I 0....— 2 0 •, '-'a1,-- M X ' 326 B r rf - I y ( i —,:53 r"--1, i,5`,'"'''"'' Cr --''' . b �. 3 k__..,.._ L r..__3 tl i L jl _ O 0-) O I CD (/) CV 17 411 __._'-_ 3G- TI�11 - ,..__._.._-X.�.. I.(,6� ......2 ---__Y-_ '1 L'� IIAIAAIIAIAIIIIIIIII ""'�'�'��7S HA 1.��L3 A f�`MM` BB� NUI IN O b $ �. :_.' .' 00 0� F:_.::�� Orris ism, 719 3 }9 138 2 , `p AD-I. 1 � .. E� (r r"'-- '; .��C2 „ . 4 v ,95CD ® CC A 3 8 Ii ...".__ .. 8 € 95CD 30CD - 06 Off\ - t: �_1 0. - ,-'NJ , 75CQ 8 WI C� Ti 13 x }31 3? '21 NMI = I mow I O ru�•I nA I 120 .-..-.,_ 3� �- { I i ^ prsl.. ,rex. Mli nA4i. Mu y( ( r' •�..L F- E n i E I IFA . 2v SNACE R ft` �! 1€M,_-_.._ - g At1J i f== I _ ! cap GAB I "- ,' , _..._.._._.. - :.„„., --- �__:-� NSI I i! I 1 t -- 1 r_ cEiLV c r BEWa. ‘_,t _ _ I I i Y r7 7 i r- E 44 x 134 323 i' B t. EC � � o { ;' E-1 3 15C1� �I O -_ Q B .' iSCD i1 �QTf t C3} O �TE. O �.-� - 311 IAS 30CD ` FdIT. • :0?VF., M. L • \ —., DRAWN BY I I p �I I - F�� J I . 1 .., 1 ! TASK, I t I ...._.._,L___; y L. ” JM 145A .,_.111-1<> moo; CHECKED BY ()f I 1 y Ft � �1 1 REV. TITLE DATE � '". :� 10 1ST SUBMITTAL 6/25/2020 A = I \ \ 410' G H REVISIONS WIRE SCHEDULE PLOT DATE N 1ST FLOOR AREA OF WORK - FIRE ALARM DEVICE LAYOUT PLAN SYMBOLS CD 1 SCALE: 1.4?_} CABLE TYPE A BCDE FHPX 6/25/2020 12 AWG PAIR • 14 AWG PAIR • • • I SYMBOL DESCRIPTION 16 AWG PAIR • SCALE RULER 8 6' 18AWG PAIR • • • PROJECT NUMBER FPLR OR FPLP(AS REQUIRED) APS6A AUXILIARY POWER SUPPLY 12V SAH SEALED LEAD ACID BATTERY SHIELDED 09324 TWISTED • CC IS ADDRESSABLE SYNCHRONIZATION OUTPUT MODULE RATED FOR UNDERGROUND AND WET CONDITIONS AS REQUIRED) CABLE USE SIGNAL LINE CIRCUIT(SLC) • RHI ADDRESSABLE HIGH OUTPUT CONTROL RELAY MODULE CONVENTIONAL INITIATING DEVICE CIRCUIT(IDC) . ZONE INPUT • PERMIT NUMBER INTELLIGENT OPTICAL SMOKE DETECTOR 0 w/DETECTOR BASE RELAY NOTIFICATION PPLIANCE CIRCUIT(NAC) • TBD REMOTE ANNUNCIATOR 24VDC POWER • CEILING HORN STROBE REMOTE ANNUNCIATOR R5485 DATA • AUDIO RISER • CEILING STROBE SPEAKER CIRCUIT • DOOR HOLDER CIRCUIT • • AUXILIARY 24VDC POWER • THE INFORMATION ON THIS DRAWINu —— IS THE ORIGINAL, UNPUBLISHED WORK OF PERFORMANCE SYSTEMS INTEGRATION LL.0 NOTE:RS232-18AWG PAIR/TWISTED,SHIELDED DISCLOSURE, REPRODUCTION. OR USE NON-POWER LIMITED CIRCUITS CAN NEVER SHARE PATHWAYS WITH POWER LIMITED CIRCUITS WITHOUT THE PRIOR WRITTEN CONSENT OF PERFORMANCE SYSTEMS INTEGRATION LLC IS PROHIBITED. SHEET NOTES: SHEET TITLE 1ST FLR AREA OF WORK im 120VAC MAIN POWER (BY OTHERS) FOR THE FIRE ALARM SYSTEM. THIS SYSTEM REQUIRES A DEDICATED DEVICE LAYOUT v CIRCUIT THAT IS LABELED"FIRE ALARM CIRCUIT'AND IS ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL. O CIRCUIT BREAKER LOCATION(S)SHALL BE PERMANENTLY NOTED AT ALL FIRE ALARM PANELS 1 /8" = l'-0” O LOCATE FIRE ALARM EQUIPMENT IN ELECTRICAL ROOM. FIELD VERIFY LOCATION. Z ® ROOM DESCRIPTION NOT SUPPLED. NOTIFICATION REQUIRED IF NORMALLY OCCUPIED BY MORE THAN ONE OCCUPANT-COORDINATE WITH PSI. CV X O TIE REQUIRED BUILDING SYSTEM(S) TO SUPPLIED SIGA-CRH-COORDINATE WITH PSI. SHEETco ILI EXAMPLE: DOOR HOLDERS, FSD ACTUATION, HVAC INTERFACE... in FA-050 U c. Q