Loading...
Permit CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT !IN �. ' COMMUNITY DEVELOPMENT Permit#: F PS2021-00042 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 4/15/2021 Parcel: 2S 101 DB00100 Jurisdiction: Tigard Site address: 7320 SW HUNZIKER RD 102 Project: Neighborhood Health Center Subdivision: None Lot: None Project Description: Fire sprinkler permit-relocate(6)and plug(3)fire sprinkler head drops to cover new floor plan Contractor: AFP SYSTEMS INC Owner: HILLTOP BUSINESS CENTER LLC 19435 SW 129TH AVE 9430 NW KAISER RD TUALATIN, OR 97062 PORTLAND, OR 97231 PHONE: 503-692-9284 PHONE: FAX: 503-692-1186 FEES Description Date Amount Specifics: Permit Fee-COM 04/14/2021 $75.30 12%State Surcharge-Building 04/14/2021 $9.04 Type of Use: COM Plan Review-Fire Life Safety-COM 04/14/2021 $30.12 Class of Work: ALT Type of Const: VB Info Process/Archiving-Sm$0.50(up to 04/14/2021 $0.50 Occupancy Grp: B Height: ft 11x17) Stories: 3 Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Wet Standpipe Required: Hazard: LT Density: 0.1 Design Area: 1500 K Factor: 5.6 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $114.96 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $1,400.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: Hotly Va�De,weg.e Permittee Signature: OwAppli,. '" Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project Approved plans are required on the job site at the time of each inspection. Building Permit Application 4- 1-124 Fire Protection System FOR OFFICE USE ONLY City of Tigard Rodfe'ged 05f Iry ZUZI PermitNo.:Fi .2OZ( ovvz • 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review 7/ �Q� / Phone: 503.718.2439 Fax: 503.598.1960 Date/B A Od1er PermiEzait e FIZI' / G n It I1 Inspection Line: 503.639.4175 Date Ready/By: ® See Page 2 for Internet: www.tigard-or.gov Notified7Method:. ®2621 Supplemental Information / TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1-and 2-family dwelling ®Commercial/industrial Valuation: $ ElAccessory building ❑Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address:7320 SW Huazlker Rd.. New dwelling area: square feet City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.:102 Project name:Neighborhood Health TI Covered porch area: square feet Cross street/directions to job site:Hilltop Business Center Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees'are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Relocate 6 and plug 3 fire sprinkler head drops to cover new floor plan. Valuation: $$I,4O0.00 Existing building area: square feet New building area: square feet 0 PROPERTY OWNER 0 TENANT Number of stories: 3 Name: Type of construction: V-B Address: Occupancy groups: City/State/ZIP: Existing: B Phone:( ) Fax:( ) New: no change ® APPLICANT 0 CONTACT PERSON NOTICE Business name: All contractors and subcontractors are required to be Contact name: licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: jurisdiction in which work is being performed.If the City/State/ZIP: applicant is exempt from licensing,the following reasons apply: Phone:( ) Fax::( ) E-mail:hannahCuafpsys.com CONTRACTOR BUILDING PERMIT FEES* (Please refer tefee schedule) Business name:AFP Systems Inc. Permit fee: Address: 19435 SW 1291h Ave State surcharge(12%of permit fee): City/State/ZIP:Tualatin,OR 97062 FLS plan review(40%of permit fee): Phone:(503)692-9284 Fax:(503)692-1186 (Due upon application submittal.) CCB tic.:6753/1- Total permit fees: IA':57 Amount received: Authorized signature: -� This permit application expires if a permit is not obtained Print name:Steve Frost Date:04/14/2021 within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. I:1BuildinglPermiteXPS-PermitApp_071514.doc 440-0613T(11/O2iCOM!WEB) City of Tigard: Fire Protection Permit Checklist Page 2- Supplemental Information Describe work to be done: 1.) Type of Work: 2.) Addition/alteration only to sprinkler heads: 3.) Addition/alteration only to alarm devices: ❑ New system Number of sprinkler heads: 2 Number of alarm devices: ® Addition or ® 1-10 heads: Affidavit required and ❑ 1-5 devices: Affidavit required and Alteration (3) copies of sketch showing area (3) copies of sketch showing area to existing of work within building structure of work within building structure system ❑ 11+ heads: Plan review required and ❑ 6+ devices: Plan review required and (3) sets of plans. (3) sets of plans. Additional description of work: Type of System (Complete A,B, C or D as applicable): A.) Commercial Sprinkler jZ Wet ❑ Dry Additional Standpipes Information: Hazard Group LH Density 0.10 Design Area 1500 K.Factor 5.6 Sprinkler Project Valuation: $ 1,400.00 B.) Type I- Hood Fire Suppression System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Batten Calculations 0 Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler(Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A,B&C above): $ 1,400.00 Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage(see D above): $ State Surcharge (12%of permit fee): $ FLS Plan Review(40%of permit fee): $ TOTAL: $ X:\Permits Steve new\Tigard\Jobs\Neighborhood Health 11-FI'S_PermitApp.doc 2 INCity of Tigard Permit No.: E ZOZ.d-QOO Ili • 13125 SW Hall Blvd.,Tigard,ORi �4 ` Phone: 503.718.2439 Fax: 503 598 1960 Date Received: �/ l ���� Inspection Line: 503.639.4175 WA TIGARD Internet: www.tigard-or.gov .,, By: 1� OF1 T1 iCi W . it.) FIRE SPRINKLER AFI IPAVIT FOR ALTERATIONS OR TENANT IMPROVEMENTS (1 to 10 SPRINKLER HEADS WITHOUT PLANS) Ct Cp18 OV Project Name: Neighborhood Health TI Occupancy: B-office Job Address: 7230 SW Hunziker St., Tigard, OR 97223 Type of Construction: V-B Suite: 102 Contractor: AFP Systems Phone: 503-692-9284 Number of Proposed or Altered Heads: 9 Type: Wet Hazard: light Density: 0.10 I Steve Frost/AFP Systems Oregon Construction Contractors Board No. 67534 certify the following is true and reasonably defines the scope of work for this project: a) All work is limited to drops and armovers in a light-hazard occupancy. b) Positions of sprinkler heads relative to architectural features such as soffits, beams, partitions, walls, etc. complies with current adopted edition of NFPA 13. c) The proposed work does not require hydraulic calculations. d) Only one sprinkler head will be installed from one drop(exception: up to two heads from one drop may be installed when each head is in a separate fire area). e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13. f) Tenant improvements in a new building shall be equipped with Quick Response heads(see 2002 NFPA 13, Section 8.3.3.1 for exceptions). g) The installation shall comply with the requirements of the current adopted edition of NPFA 13. h) Piping shall not be concealed until hangers and bracing are inspected. i) Final approval shall be subject to onsite tests and inspections. In addition, I understand the following is required: • Submit(3) copies of a sketch showing the area of work within the building's structure. • Building fire protection system permit. • A copy of this document with a copy of the sketch attached shall be available for all inspections. Digitally signed by Steve Frost Steve Frost eDIrsSteve FrosLo AnFPSystems,ou, 04/14/2021 Signature: email= eve@a(psyscom,cUS Date: Date:art 1.1M]3 14:15:SD-0/W Print Name: Steve Frost I:\Building\Forms1FiresprinklerAffrdavit_071514.docx Page 1 of 1