Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
4C52049NweEhScQ OFFICE COPY PRIME ELECTRICAL SERVICES, LLC. � '� � ' Electrical • Communications♦ Life Safety♦ Security♦ CCTV PO Box 872395 Vancouver,WA 98687♦Phone(360)335-3565 APR : : 2021 RECENT OR CCB#217825♦ WA#PRIMEE5822BE CITY OF TIGARD 13U!LD!NG DIVISION FIRE ALARM SYSTEM SUBMITTAL DRIVEWAY FINANCE TI 9020 SW Washington Square Rd. Tigard, OR 97223 March 9, 2021 VALIDITY OF PERni THE ISSUANCE OF A PER ; iT BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVEP IT THE CODE OFFICIAL FRO:11 RRECTION pEOFIERRORS. OSOSC 105.4 Proposed by Prime Electrical Services PO 21-152 Project Manager: Oleg Primachenko ---444411111111 Honeywell laSILENT' CHT 5495 Distributed Power Module The 5495 Distributed Power Module is the most powerful and cost- effective power supply available today.It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor5,Gentex®,AMSECO®,and Wheelock. The 5495's switch mode power supply design is up to 500/0 more efficient than competitive linear mode power supplies.Also,ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. The 5495 is a 6 amp notification power expander that provides its own AC power connection,battery charging circuit,and backup battery.The 5495 is the costeffective solution for powering notification appliances required by the Americans with Disabilities Act(ADA).The 5495 has built-in ANSI »wi cadence pattern,which can upgrade older control panels that lack cadence capability. CONNECTION TO LOCAL FIRE CONTROL 5495 The 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC.The control panel's notification circuit is connected to one of the inputs on the 5495.The control panel's notification circuit end-of-line resistor is also connected across two terminals on the 5495,which provides supervision between the 5495 and the fire control panel.Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the 4.7kf end-of-line resistors provided.Since the 5495 draws very little power from the control,it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. FEATURES & BENEFITS • UL Listed for 6 amps • Four power-limited • Ground fault detector/ • Built-in • Operates with most of notification power notification outputs;2 indicator synchronization for polarized,UL Listed • Power supply's Class A or 4 Class B,or . Independent trouble appliances from notification devices advanced switch mode 1 Class A and 2 Class rela System Sensor', •B y Gentex',AMSECO,' ANSI Cadence pattern design reduces • AC loss delayoption output capability damaging heat and • Additional continuous r and Wheelock built-in shuts off power to manages power up to auxiliary output non-essential • Stand alone operation 50%more efficiently • 3 amps per output high-current • Lightweight design than other systems circuit accessories Like adds to ease of • Dip switches allow for • 2 inputs;2 Class B or 2 magnetic door holders installation and easy reconfiguration Class A reduces shipping • 24 VDC filtered output costs voltage 5495 Technical Specifications Model 5495 Block Diagram For a complete listing of all compliance approvals and certifications,please visit www.sitentknight.com. Signal Circuit Output Signal 1 Signal 1 Input Microsoft,Windows,and Distributed Signal 2 the Windows Logo are Signal Circuit Output Signal 2 Power registered trademarks Input Module 5495 Signal 3 or trademarks of (Optional) IMicrosoft Corporation. Signal 4 120 VAC Aux.Power System Sensor°and Honeywell°are registered Trouble Output trademarks of Honeywell Local Fire Control (Alternative to notification International,Inc circuit trouble.) This document is not intended to be used for SUPERVISION Amps per output circuit:3.0(6.0 amps total) installation purposes.We The 5495 supervises a variety of functions Notification circuit output:Alarm Current(for try to keep our product including: typical voltages)drawn from main panel's information up-to • Low AC power notification appliance circuits. date and accurate.We 12 VDC 6.5 mA cannot cover alts i c ticticippate 24VDC One input circuit:15 mA;Both input all requirements.All • Earth ground fault circuits:0 mA specifications are subject • Auxiliary output power limit condition No.of inputs:2 to change without notice. • EOL supervision trouble or power Limited Input configuration:2 Class B or 2 Class A For Technical Support, Input voltage range:9-32VDC call800-446-6444, condition at an output P 9 When a trouble condition occurs,the 5495 creates Battery charging capacity:35.OAH a trouble condition on the host control signal INDICATOR LIGHTS circuits to which it is connected.the 5495 still maintains the ability to be activated by the host AC power on:Green control.In addition,the 5495 provides a Form C Battery trouble:Yellow trouble relay output as an alternative to using the Ground fault:Yellow notification circuit trouble. Aux trouble:Yellow Output troubles(1-4):Yellow PHYSICAL Dimensions:12.25"W x 16"H x 3"D(30.88 cm W x ORDERING INFORMATION 40.64 cm H x 7.62 cm D) 5495:Distributed Power Module ENVIRONMENTAL ACCESSORIES Operating Temperature:32°Fto 120°F (0°C to SK-SCK:Seismic Compliance Kit 49°C) p Humidity:10%-93%non-condensing) AGENCY LISTINGS ELECTRICAL • ULlisted AC input:120 VAC at 2A • CSFM 7300-0559:123 Output:24 VDC at 6A • Meets NFPA 72 requirements Current:Standby 75mA;Alarm 205mA Auxiliary power circuit:l • MEA 429 92 E Vol Xll Notification circuits:4 • OSHPD(CA)OSP-0065-10 Output configuration:2 Class A(Style Z);4 Class B (Style Y)(1 Class A 8/.2 Class B) For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight Honeywell 122 Clintonville R le Road Northford,CT 06472 Doc 350395l 9ev HI 11/17 MINT"800-328-0103 ©2017 Honeywell International Inc. ®KNIGHT SYSTEM �$ SENSOR' tiiitttii I1Iitt11) FilF Indoor Selectable- Output Horns, F Al* 1 1•A Strobes, and X ' Horn Strobes for Wall Applications System Sensor L-Series audible visible notification , sirt- - products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. z,. Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,standard and compact devices,and plain,FIRE, and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15,30,75,95, 110, 135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING LISTED APPROVED S5512 FM approved except 7125-1653:0504 54011 for ALERT rmdels 7135-1653'6503 3057383,3057072 AVDS865-05•2122/2018•Page 1 • L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 17/s-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 1 7/e-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit"'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements q s for visible s ble signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Rang& 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6'1 x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05•2/222018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 1 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 75cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-175 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9' Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 "Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on, AVD5865-05.2/22/2018•Page 3 L Series Dimensions - 191• a_3.41. 3Ar_® 4d5 mm BBmm LW 357'-- 1.55' 88 mm 125' 32 mm 32mm (9.1 cm) (9.8 cm) 11.1 ! al\ 1 I UP o r ! : C Ali r (13.7 cm) U 1111 139.9mm r r to i•ai'i 1 0 died• A0548-00 A0547-00 40557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL 4.70" (11.94 cm) 1.91' 4.7" 1__.i • m . 52'--�(248m) 119 mm 32 mm (1224cm) 1.85' (A89 c m)f (3.18mm) t //� --��'''` � , -- 0. . , , I 1 ,to.:1+ [• icAcliiit ••SS�4 C 7 5.67• �; aS rk 14,85 cm)(145.467c"m) 144 mm r 4t4t4h o YY�� iri5i2irr. t_- JJ ‘ . , „in: 1.1.... .„, A0554-01 Strobe,Horn Strobe A0550-00 Horn A0549-00 Wall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns' P2RL 2-Wire,Horn Strobe,Red HRL' Horn,Red P2WL 2-Wire,Horn Strobe,White HWL' Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL' Compact Horn,Red P2GWL 2-Wire,Comp 2 fils act Horn Strobe,White HGWL" Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White SBBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe,Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. All-ALERT models have"ALERT"marking on cover. 'Horn-only models are listed for wall or ceiling use. SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 11120180ystem sensor. �y' SENSOR Phone:800-SENSOR2•Fax:630-377-6495 Product spepnductin subject to change vnuwutnotce.VisnfPrimsensorcorn for current product information,holuO'ng the latest versbn of this data sheet. www.systemsensor.com AVD9885-05.222/2018 SYSTEM �$ SENSOR Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower �. current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- consuming ground faults. • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING LISTED A 55512 FM approved except 7125-16530504 54011 for ALERT models 7135-1653.0503 3057383 AV05868.02.12/01/2017•Page 3 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Serles products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 411/16 x 2 1/8-inch back box.The module shall also control two Style Y(class 8)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02.12/01/2017•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output(d8A) t s 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02•12/01/2017•Page 3 • L-Series Dimensions 2.47'(62.7 mm) 1.37'(34.8 mm) - 6.92'diam. (...- 2.5' 6.83'diam. (175.77 mm) (64 mm) (173 mm) pifH,M\ \ III Y7-p O p\1 �— C ill o ®g go — Y Y A0545-00 M.546-0D Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box iiiir7 .------ -11111111 . 1! • O moo_i s— e' t 91 �� 1i -■ �_____ ��rext \ ",^n r u,0 Mac I oh ii(S { VP \ �_Vjlr x l il I ;11��F � Yrfit., z illaw A0404-01 A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". *� SYSTEM C,2017 System Sensor 3825 Ohio Avenue•St.Charles, IL 60174 Productspeacationssubjecttochangemtha4notice,Vat systemsensorcorn �_$ SENSOR" Phone:800-SENSOR2•Fax:630-377-6495 for current product ini«rnsuon.mrfudng the latest versiouoi this data sheet . AVDS868-02•12/01/2017 Data Sheet •NP SERIES - NP7-12 Reliability is your Security Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied their ,,,,� ,, .;!? t 80 years of experience in the lead acid battery field to lirr """„ orr ' produce the optimum design of Sealed Lead Acid YUASA :•. "" I' t batteries. "' FEATURES ---.." • Superb recovery from deep discharge. • Electrolyte suspension system. Terminals • Gas Recombination. NP batteries are manufactured using a range of terminals • Multipurpose: Float or Cyclic use. which vary in size and type. Please refer to details as • Usable in any orientation • Superior energy density. shown. • Lead calcium grids for extended life. Operation in any Orientation • Manufactured World wide. • Application specific designs. The combination of sealed construction and Yuasa's unique electrolyte suspension system allows operation in Technical Features any orientation,with no loss of performance or fear of Sealed Construction electrolyte leakage. Yuasa's unique construction and sealing technique Valve Regulated Design ensures no electrolyte leakage from case or terminals. The batteries are equipped with a simple, safe low Electrolyte Suspension System pressure venting system which releases excess gas and All NP batteries utilize Yuasa's unique electrolyte suspension automatically reseals should there be a build up of gas system incorporating a microfine glass mat to retain the within the battery due to severe overcharge. Note. On no maximum amount of electrolyte in the cells.The electrolyte is account should the battery be charged in a sealed retained in the separator material and there is no free container. electrolyte to escape from the cells. No gels or other General Specifications contaminants are added. Control of Gas Generation Nominal Capacity(Ah) NP7-12 The design of Yuasa's NP batteries incorporates the very latest Layout 20hr to 1 .75vpc 30°C 7 oxygen recombination technology to effectively control the 1 ohrto 1 .75vpc 20°C 6.4 generation of gas during normal use. 4 ® 5hr to 1.70vpc 20°C 5.9 Low Maintenance Operation Ihrto1 , 0vpc20°C 4.2 Due to the perfectly sealed construction and the Q Voltage 12 recombination of gasses within the cell,the battery is Energy Density mil 20nr7 91 almost maintenance free. Specific Energy(m.kgzohr) 32 Terminals Int.Resistance(m.Ohms) 25 Maximum discharge(A) 40/75 Faston tab!187 A Factor tab:250 D Short Circuit current(A) 210 Dimensions (mm) 185.aw .off, INCF[=MM sw..mc a5 f7-1=M3,4 - `' .251) 6.35 I I .310 7.90 Length 151 .085 .185 4.70 .250 6.35 Width 65 MINIM — .124 3.15 .16 4.0 A .098 2.50 s .031 0.8 Height overall 97.5 =I .059 1.50 .031 0.80 .020 0.5 Weight(Kg) 2.65 I .004 0.50 004 Terminal ND III II+- . 0.10 03i ..001A.00.1 Layout 4 Terminal Torque Nm - NPII Data Sheet NP SERIES - NP7-12 Lead Calcium Grids Long shelf Life The heavy duty lead calcium alloy grids provide an extra margin of The extremely low self discharge rate allows the battery to be performance and life in both cyclic and float applications and give stored for extended periods up to one year at normal ambient11 unparalleled recovery from deep discharge. temperatures with no permanent loss of capacity. Long Cycle Service Life Operating Temperature Range Depending upon the average depth of discharge,over a thousand The batteries can be used over a broad temperature range discharge/charge cycles can be expected. permitting considerable flexibility in system design and location. Float Service Life Charge —15°C to 50°C The expected service life is five years in float standby applications. Discharge— 20°C to 60°C Separators Storage —20°C to 50°C (fully charged battery) The use of the special separator material provides a very efficient insulation between plates preventing inter-plate short circuits and SELF DISCHARGE CHARACTERISTICS prohibiting the shedding of active materials. %) m CYCLIC RECHARGE REGIME 6'C(32°F) TE -- _ C MCCa" ..Saw Mew F -__-_"-- .._ 11iC I60'FI W US - Iss 1a ETC Fl I+ , Cher", an- M# I�`1 u -£Tm --� I. I RTC GRAM) arc(6M IMMOp 14 25 0.+s 4 is . 1 O I 13 I S CVAnl VG Rpm °a+ p 5e m 3 6 a 12 15 Ie ,.eon Nips 13 STORAGE TIME(MONTHS) cos M Ga"aa`"""- FLOAT CHARGE CHARACTERISTICS NP DISCHARGE CHARACTERISTICS 11 8g d 5 CURVES AT 252C (77°F) `� � 0.250A-22T5VRC CONSTANT VOLTAGE CHAft0BJO S 1%) Ia0N M A72D`0186°F) RR FOR 13V FOR 6V GG Note C°Divan capatlb as stelae nn San.Watery in An IS. CA BATTERY BATTERY 1>0 13A- 6S NP AT S°CI]i'FI ]36_ G(.pV0.UAF ° -- --.-(■■11 ILO (W ..-.- _-_ -___ i6. 6-6 _ auntie VOLTAGE IaA 126 55 "m IIlill .h a .fiW I' ... CID 6.13 n.0 111114/1 I11'1 ' AS --AFTER 1m%104001RS5 a+0 `AS -.-AFTER 66%DKpMABE SK 10.D_ 5.0 am ' 12A i . „'11� .EN 2D aaa 8.0- 46..'I" h•I S.98 T ___ -__1 -la IN3CWNENT ILO . . D x • a a .. la u w n 20 6.°- aD • CHANGING TSAR RAMS) •E !i 1111,11., TYPICAL DISCHARGE CHARAC- IANUTES DISCHARGE TIME HOURS TERISTICS NP RANGE CYCLE SERVICE LIFE IN RELATION FLOAT SERVICE LIFE NP RANGE TO DEPTH OF DISCHARGE TESTING CONDITIONS:DISCHARGE CURRENT:0.17C Amp.IF.V 1,TVCELL CHARGING CURRENT:6A0C Amp. (A�) TESTING caNDRIDNs:FLOATING VOLTAGE:1.275VPC CHARGING VOLUME:125%OF DISCHARGED CAPACITY L AMBIENT TEMPERATURE:WC((O'FTO RP) $ Iµ%) ANIBRNTTEMFERANRE:PPC T026C(SWF TO TTFI 120 'm R 100/ m 0 50 _`� 2J ` p le 33%DEPTH le OF OISCHS ROE OD 20 t 1 0 1 2 p 3 4 5 5.5 LIFE(YEARS) 0 20, 010 sop °OO IOW MO +� NUMBER OF CYCLER 117 Yuasa Battery Inc. Distributed by 2901 Montrose Ave Laureldale, PA 19605 www.yuasabatteries.com LYUASA Registered number 1548820 Cat.No. NP7-12 January 08