Loading...
Plans RECEIVED JAN 1 1 2021 CITY OF TIGARD BUILDING DIVISION Building Plans for City of Tigard Building Permit Application Customer: The Fountains at Summerfield condominiums HOA 15685 SW 116th Ave., #105 Tigard, OR 97224 Contact - Paul Brock, 858-212-9105, pbrock987@gmail.com Contractor: Jon Erickson, 503-730-9220 OFFICE COPY jon.evenjobs@gmail.com CCB 162397 CITY OF TIGARD,. REVIEWED FOR CODE COMPLIANCE Scope of Work— Repair Decks • Replace perimeter joists with PT Approved: w • Repair joist and soffit dry rot OTC: [ J Permit#: 01 I -fi n CI 4 • Replace 42" guardrail and infill to comply with Address: wt4.75zSu, 11471, c'`7 IBC multi-family code Suite#: -7 7 $y= '• Date: 4_ I • VALIDITY OF PERMIT File Name: Fountains Deck Permit Plans REVISED.pptx THE ISSUANCE OFA PERMIT BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS. OSSC 105 3/19/20 Fountains at Summerfield - Deck Building Plans 1 • Typical Deck Construction and Size — 102 SF < > �s;y 114.5' Imbedded 6x6 PT E„ 4x4 PT Posts 2 x 8 PT blocking between joists attached with Three 16D 3-1/2"n HDG 43" >< 15" >< Ref: 2014 Oregon Structural 56.5" Specialty Code—Table 2304.9.1-29 Blocking supports Simpson Rim joist attached to 2"x8" Joists 16" OC Tension Ties DTT2Z. Two lateral joists with DTT2Z brackets required for Three 16D 3-1/2"n HDG --� posts in this position. See Beam 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty Tension Ties— page 337 Code—Table ai N 2304.9.1-29 .1 House —Brick exterior 43 > Scale — 12"/increment �.�._ J L 3/19/20 Fountains at Summerfield - Deck Building Plans 2 Water Penetration Remediation — Cross Section Posts - 4x4 PT Flashing 2" x 3" Resurfacing material 3/4" exterior plywood decking 44 Un 0 E it 00 x N Hardi-plank Fascia 9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by'/." extension. Pre-paint before adding flashing /" plywood soffit Scale— 1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 3 • • Guard Rail Post — Simpson Tension Ties Posts—4x4 PT Simpson DDT2Z \\\\\\\\\\\\\\\\\\\\\\ Attach to lateral joist with 8 SDS 1.5" screws '/" x 6" Machine Bolt ! DTT2Z supports 1800 lb. HDG with nuts and ~- tension load. Meets IBC washers Code for multi-family deck co o guardrails. N E Refer to attached Simpson catalog - Deck Tension Ties Lateral Joist page 337 — ‘111 Also refer to Simpson code compliant Guardrail Post Connection bulletin T-C-GRDRLPST17 Scale— 1" increment immoom 3/19/20 Fountains at Summerfield - Deck Building Plans 4 Typical Guardrail and Infill Section — 50" max. between posts Simpson Strong Drive A Wide Screw SDWS 4", 2 x 4 TKC 2 3/8" TL. Two per Cap R7111111111111.111111.111.11111.11111Railing Octal/ end, three in mid span, ' ,' ' 7.7.21 , 1" x 5 °' �attach � � : rRailin ``exteri fiadhes Railing Support to m 2x4 TKC . o cr o Attached to a iii, 1 i / ii-F. ,,, �i Railin.crg and ! Installation of Posts with balasters and rails adhesive and t per mfg installation Simpson p instructions. Strong Drive Wide Screw SDWS 4", 2 3/8" TL. ,/ Railing 2 x 4 TKC Railing Infill DecKorator aluminum 2.75" space balaster 3/" x 32". • • Spacing 3.75" DecKorator Scale 1" increments • 0 CodeCompliance Research Report iiiiiiiiiiii CCRR-0161 3/19/20 Fountains at Summerfield - Deck Building Plans 5 of 5