Loading...
Plans RECENED APR 3 2020 CITY OF TIGARD BUILDING DIVISION Building Plans for City of Tigard Building Permit Application Customer: The Fountains at Summerfield condominiums HOA 15685 SW 116th Ave., #105 Tigard, OR 97224 Contact - Paul Brock, 858-212-9105, pbrock987@gmail.com Contractor: Jon Erickson, 503-730-9220 OFFIG COPY ion.eveniobs@gmail.com CCB 162397 CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Scope of Work— Repair Decks Approved: • Replace perimeter joists with PT OTC: I • Repair joist and soffit dry rot Permit #: avionpz,p Epp J 1 aca U91 Address: itc`'64.5—S Sw > >y inT— • Replace 42 guardrail and infill to comply with Suite # IBC multi-family code By: Date:e1_a9 -ao VALIDITY ®F Pr`E? 11— File Name: Fountains Deck Permit Plans REVISED.pptx THE ISSUANCE OF A PEGP'MT BASED ON CCNSTRH'CT!ON DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS. OSSC 105.4 3/19/20 Fountains at Summerfield - Deck Building Plans 1 • Typical Deck Construction and Size — 102 SF Brick Col. 114.5" ISxik.S < Imbedded 6x6 PT �— �— 4x4 PT Posts A 2 x 8 PT blocking between joists attached with Three 16D 3-1/2"n HDG ><--->< Ref: 2014 Oregon Structural 43" 15" 56.5" Specialty Code—Table 2304.9.1-29 2"x8" Joists 16" OC Blocking supports Simpson Rim joist attached to Tension Ties DTT2Z.Two lateral joists with DTT2Z brackets required for Three 16D 3-1/2"n HDG posts in this position. See Beam — 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty ^ Tension Ties—page 337 Code—Table o; N 2304.9.1-29 r' House— Brick exterior Q 43" Scale— 12"/increment 3/19/20 Fountains at Summerfield - Deck Building Plans 2 Water Penetration Remediation — Cross Section Posts—4x4 PT Flashing 2" x 3" Resurfacing material 3/4" exterior plywood decking N 0 C 03 x N Hardi-plank Fascia 9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by%" extension. Pre-paint before adding flashing 1/2" plywood soffit Scale — 1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 3 Guard Rail Post — Simpson Tension Ties Posts—4x4 PT Simpson DDT2Z Attach to lateral joist with 8 SDS 1.5 screws %" x 6" Machine Bolt DTT2Z supports 1800 lb. HDG with nuts and tension load. Meets IBC washers ' Code for multi-family deck w 'o guardrails. x, E Refer to attached Simpson catalog- Deck Tension Ties Lateral Joist page 337 N���������������������� Also refer to Simpson code compliant Guardrail Post Connection bulletin T-C-GRDRLPST17 Scale—1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 4 Typical Guardrail and Infill Section — 50" max. between posts Simpson Strong Drive A I Wide Screw SDWS 4", i ' Railing 2 x 4 TKC D 2 3/8"TL. Two per Cap Rail —Trex e , end, three in mid span 1" x 5.5" attached to 1 i Railing with I exterior adhesive. i i, Railing Support Mil I v 2x4TKC . o a oo Attached to Ni Railing and a Installation of Posts with balasters and rails adhesive and per mfg installation Simpson instructions. Strong Drive Wide Screw SDWS 4", I Railing 2 x 4 TKC Railing Infill - 2 3/8" TL. I DecKorator aluminum V _ 2.75" space balaster%" x 32". • • Spacing 3.75" DecKorator Scale 1" increments CodeCompliance Research Report I " " " " " ' i CCRR-0161 3/19/20 Fountains at Summerfield - Deck Building Plans 5 of 5