Permit l __ CITY OF TIGARD MASTER PERMIT
ig • ' COMMUNITY DEVELOPMENT Permit#: MST2021-00106
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 04/01/2021
Parcel: 2S112BD12300
Jurisdiction: Tigard
Site address: 7540 SW HANSEN LN
Subdivision: ELDERBERRY RIDGE Lot: 19
Project: Brault
Project Description: Rooftop Solar PV
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $7,888.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: 0 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Other Fixtures: 0
Drywell-Trench Drain: 0 Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=10OK: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add,500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 1
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All
Other: Y Other Description: Roof Top Solar PV System 5.44 kW Ecompasing: N
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
ALT SF VB R-3 0
Owner: Contractor:
BRAULT,JEAN M&OUMA PHOMMANETION DEVELOPER LLC Required Items and Reports(Conditions)
7540 SW HANSEN LN 3214 NORTH UNIVERSITY AVE
TIGARD,OR 97224 503
PROVO,UT 84604
PHONE: PHONE: (888)781-7074
FAX:
Total Fees: $417.61
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will
be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180
days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344.
Issued By: `t\janc.)eV .eciC_ Permittee Signature: t '1 ()kr-AN i C CA21 tY\
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
Building Permit Applicatii ECEIVE ..-3I72I2,i
Residential MAR 2 3 201� Received fOR )1II( I.' t 'i. (1A11
`��v.�f
City of Tigard Date/By: V*' 20� '/I Permit No.: 11720,71'OO/O4D
Iii i • 13125 SW Hall Blvd.,Tigard,OR 9720ITY OF TIGARD Plan Review
Phone: 503.718.2439 Fax: 503.59 Date/By: Ti♦' Other Permit:
Tn ection Line:'503'639.4175 idui°DING DIVISION Date Ready/fl : l //�1,�r� —L7a�,, ® See Page 2for
Internet: www.tigard-or.gov 1 iC,hltU Notif d/Method: z a ` `1� Supplemental Information
C-
TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING
['New construction 0 Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
❑Addition/alteration/replacemcnt ®Other: PV Solar equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
Valuation: $7888
® 1-and 2-family dwelling 0 Commercial/industrial
❑Accessory building 0 Multi-family Number of bedrooms:
❑Master builder
0 Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address: 7540 SW Hansen Ln New dwelling area: square feet
City/State/ZIP: Tigard, OR, 97224 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name: Brault Solar Install Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Lot no.: Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Installation of solar panels on existing residential roof. 5.44kW Valuation: s
Existing building area: square feet
New building area: square feet
® PROPERTY OWNER 0 TENANT Number of stories:
Name: Jean Brault Type of construction:
Address: 7540 SW Hansen Ln Occupancy groups:
City/State/ZIP: Tigard, OR, 97224 Existing:
Phone:( 503) 819-8601 Fax:( ) New:
® APPLICANT 0 CONTACT PERSON BUILDING PERMIT FEES*
(Please refer to fee schedule)
Business name: ION DEVELOPER LLC
Structural plan review fee(or deposit):
Contact name:Bonnie Leslie
FLS plan review fee(if applicable):
Address:4801 N University Ave#900
Total fees due upon application:
City/State/ZIP: Provo, UT 84604 Amount received:
Phone:( 888) 781-7074 x8530 Fax::( )
PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
E-mail: permits@ionsolar.cOnl
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System.
Business name: ION DEVELOPER LLC Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address: 4801 N University Ave#900 Solar Installation Specialty Code checklist.
City/State/ZIP: Provo, UT 84604 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:( 888) 781-7074 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB lie.: 230394 7 Total fee due upon application: S201.60
Authorized signature: 130'wytAei Leese This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Date: 03/22/2021 *Fee methodology set by Tri-County Building Industry
Print name: Bonnie Leslie Service Board.
IABuilding\Pemtits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
Building Permit Application Checklist
One- and Two-Family Dwelling FOR OFFICE USE ONI.I
City of Tigard Received
• 13125 SW Hall Blvd.,Tigard,OR 97223
Dale/B : Permit No.:
. a Phone: 503.7182439 Fax: 503.598.1960 Associated permits:
T 1[ A R D 24-Hour Inspection Line: 503.639.4175 IDElectrical ElPlumbing 0 Mechanical
Internet: www.tigardor.gov ❑ Other:
THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW 1 v., N,tt \'X
1 Land use actions completed. See jurisdiction criteria for concurrent reviews. 0 IN
ii
2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. 0 0 ❑
3 Verification of approved plat/lot. 0 0 ❑
4 Fire district approval required. Name of district: • 0 0 0
5 Septic system permit or authorization for remodel. Existing system capacity . 0 0 ❑
6 Sewer permit. ❑ 0 0
7 Water district approval. ❑ 0 0
8 Soils report. Must carry original applicable stamp and signature on file or with application. 0 ❑ 0
9 Erosion control 0 plan 0 permit required. Include drainage-way protection,silt fence design and location of catch- ❑ 0 ❑
basin protection,etc.
10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state 0 0 ❑
building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size
sheet attached to the plans with cross references between plan location and details. Plan review cannot he completed if
copyright violations exist.
1 t Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if ❑ ❑ 0
there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements
and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction
indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and
surface drainage.
12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ 0 0
and location.
13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, 0 0 ❑
furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc.
14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ 0 0
floor,wall construction,roof construction. More than one cross section may be required to clearly portray
construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings
and foundation,stairs,fireplace construction,thermal insulation,etc.
15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. 0 0 ❑
Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope.
Full-size sheet addendums showing foundation elevations with cross references are acceptable.
16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- 0 0 0
prescriptive path analysis provide specifications and calculations to engineering standards.
17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing 0 0 0
locations. Show attic ventilation.
18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered 0 0 0
systems,see item 22,"Engineer's calculations."
19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists 0 0 ❑
over 10 feet long and/or any beam/joist carrying a non-uniform load.
20 Manufactured floor/roof truss design details. 0 0 0
21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required 0 0 0
for four or more appliances.
22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or 0 0 0
architect licensed in Ore on and shall be shown to be a licable to the ro'ect under review.
23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". 0 ❑
24 Two(2)sets each are required for Items 16, 19,20 and 22 above. 0 0 0
25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. 0 0 0
26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. 0 0 ❑
27 "Drawn to scale"indicates standard architect or engineer scale. 0 0 ❑
28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard 0 0 0
Street Tree List.
29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, 0 0 0
and protection measures must be drawn to scale and must include the project arborist's signature of approval.
30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, 0 0 0
including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings
on a lot of record approved prior to September 9, 1995.
1:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
Electrical Permit ApplicatEC E I Y E D FOR OFFICE USE ONLY
City of Tigard Received
13125 SW Hall Blvd.,Tigard,OR 972z3 AR 3 2021 Date/By: Permit#:
Plan Review
lig ® Phone: 503.718.2439 Fax: 503.598.1960 DateBy: Related Permit#:
Inspection Line: 503.639.4175 CITY OF TIGARCD Ready Date/By: Jwis;e w la See Page 2 for
11l'A R I) Internet: www.tigard-or.gov ���� Notified/Method: 1 t!v'�t Supplemental Information
TYPE OF WORDING DIVISION PLAN REVIEW
❑New construction ❑Addition/alteration/replacement Please check all that apply(submit 2 sets of plans wlitems checked):
0 ®Other: PV Solar 0 Service or feeder 400 amps or more 0 Building over three stories.
Demolition where the available fault current 0 Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings.
less to ground,or exceeds 14,000 0 Commercial-use agricultural
® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building amps for all other installations. buildings.
❑Multi-family 0 Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived
❑Addition of new motor load of system.
Job#: Job site address: 7540 SW Hansen Ln IOOHP or more. ❑"A","E","I-2","I-3",
City/State/ZIP: Tigard, OR, 97224 ❑Six or more residential units. occupancy.
0 Health-care facilities. 0 Recreational vehicle parks.
Suite/bldg./apt.#: Project name: Brault Solar Install ❑Hazardous locations. ❑Supply voltage for more than
❑Service or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site: FEE SCHEDULE
nnscription I Qtr. I Each I Total I
New residential single-or multi-family dwelling unit.
Subdivision: Lot#: Includes attached garage.
1,000 sq.ft.or less 168.54 4
Tax map/parcel#: Ea.add'I 500 sq.ft.or portion 33.92 1
DESCRIPTION OF WORK Limited energy,residential
________ above sq.ft.) 75.00 2
(with
Installation of solar panels on existing residential roof. 5.44kW Limited en
ergy,multi-family 75.00 2
Addition of(1)0-30A circuit(s) residential(with above sq.ft.)
Renewable Energy 031 See Page 2
® PROPERTY OWNER 0 TENANT Services or feeders Installation,alteration,and/or relocation
Name: Jean Brault 200 amps or less 100.70 2
Address: 7540 SW Hansen Ln 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard, OR, 97224 601 amps to 1,000 amps 301.04 2
Phone:( 503) 819-8601 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email:jean.m.brault@gmail.com relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date: 401 amps to 599 amps 168.54 2
El APPLICANT El CONTACT PERSON Branch circuits—new,alteration,or extension,per panel
A.Fee for branch circuits with
Business name: ION DEVELOPER LLC above service or feeder fee, 7.42 2
each branch circuit
Contact name:Bonnie Leslie B.Fee for branch circuits without
Address: 4801 N Universit Ave#900 service or feeder fee,first 1 56.18 $56.18 2
)/ branch circuit
City/State/ZIP: Provo, UT 84604 Each add'I branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:( 888) 781-7074 x8530 Fax: :( ) Each manufactured or modular
dwelling,service and/or feeder 67.84 2
Email: permits@ionsolar.com Reconnect only 67.84 2
CONTRACTOR Pump or irrigation circle 67.84 2
Business name: ION DEVELOPER LLC Sign or outline lighting 67.84 2
Address: 4801 N University Ave#900 Signalnel, circuit(s)ern or extension. 0 See Page 2 2
panel,alteration,or extension.
City/State/ZIP: Provo, UT 84604 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
Phone:(888) 781-7074 Fax:( ) Investigation(1 hr min) 90.00/hr
Industrial plant(1 hr min) 78.18/hr
Email: permits@ionsolar.com Inspections for which no fee is
specifically listed '/a hr min) 90.00/hr
CCB Lic.: 230394 Electrical Lic.: C1524 Suprv.Lic.: 6098S l y
ELECTRICAL PERMIT FEES
Suprv.Electrician signature,required: ,r�rr®.a• � � Subtotal: $189.74
Print name: David S Conrad Date: 03/22/2021 0 Plan Review Required(25%of permit fee):
State surcharge(12%of permit fee): $22.77
Authorized signature: ( ovvitie,L
osUe TOTAL PERMIT FEE: $212.51
This permit application expires if a permit is not obtained within 180
Print name:Bonnie Leslie Date: 03/22/2021 days after it has been accepted as complete.
" Number of inspections allowed per permit.
1:1Building\Permits\ELC_PcrmitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB
Electrical Permit Application-City of Tigard
Page 2-Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY: FEE SCHEDULE
Fee for all residential systems combined: $75.00 Description
Qetr. Each Total
y Renewable electrical energy systems:
Check Type of Work Involved: 5 kva or less 100.70 2
5.01 to 15 kva 1 133.56 $133.56 2
❑ Audio and Stereo Systems* 15.01 to25 kva 200.34 2
Wind generation systems in excess of 25 kva:
n Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
n Garage Door Opener* >100 kva(fee in accordance 552.26 2
with OAR 918-309-0040)
❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System*
Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00i hr
specifically listed('/__hr min)
COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES
Subtotal(Enter on Page 1): ] $133.56
Fee for each commercial system: $75.00 * Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
❑ Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
❑ Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
❑ Protective Signaling
❑ Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I:\Building\PwmiieuELC_rerinitApp_ELR ERE.doc Rev 06/17/2015
RECEIVED
City of Tigard MAR 2 3 2021
'' Building Division CITY OF TIGARD
13125 SW Hall Blvd,Tigard,OR 97223 3UILDING DIVISION
Phone: 503.718.2439 Fax: 503.598.1960
TIGARD Inspection Line: 503.639.4175
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 7540 SW Hansen Ln
City: Tigard Zip: 97224
Owner's Name: Jean Brault Date: 03/22/2021
Contractor's Name: ION DEVELOPER LLC CCB #: 230394
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? 0 No OSSC or ORSC for
design requirements.
Is the wind exposure X Yes If"Yes", qualifies for
Wind Exposure "C" or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes X❑ Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
If"Yes", qualifies for
structures other than
Yes the prescriptive path.
above C
No
1
I:Building/Forms/Ph oto V olta ic-Checkl i st02-O 1-11.doc x
� r
Is the construction Yes
Type of material wood and does
YP If"Yes", qualifies for
the construction qualify
Construction as"conventional light ElNo the prescriptive path.
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ElYes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
•
Nominal lumber. If"Yes", qualifies for
n Yes the prescriptive path.
❑ No
Is the combined weight 0 Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance 0 Yes
with Section 305.4(3) of If"Yes", qualifies for
the 2010 Oregon Solar ❑ No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max.two layers the prescriptive path.
❑X of composition
shingle.
Is the roof mounted X❑ Yes
Connections of solar assembly
If"Yes", qualifies for
the solar assembly connected to roof ❑ No the prescriptive path.
to the roof framing or blocking
directly?
2
I:Building/FormslPhotoV oltaic-Checklist02-01-11.docx
Is the gauge 26 or less? Yes If"Yes", qualifies for
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. 'h"thickness, Yes
decking connected to If"Yes", qualifies for
framing members No the prescriptive path.
w/min. 8d nails @
6"/12"o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
El
solar modules module to the roof Yes the prescriptive path.
surface. ❑ No
3
I:Building/FormsfPhotoVoltaic-Checklist02-01-11.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size,type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: SILFAB
Model Number: 340NL
Listing Agency:
4
I:Building/Fonns/PhotoVoltaic-Checklist02-01-I 1.docx