Loading...
Permit CITY OF TIGARD MASTER PERMIT 111 COMMUNITY DEVELOPMENT Permit#: MST2021-00123 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 04/12/2021 T I is;A R n 9 Parcel: 2S114AB05700 Jurisdiction: Tigard Site address: 9345 SW MILLEN DR Subdivision: KNEELAND ESTATES Lot: 44 Project: Hesseldahl Project Description: Rooftop Solar PV BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $5,972.56 Rear. 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckfw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Tvoes Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr. 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System- N Garage Opener: N All Other Y Other Description: Roof Top Solar PV System 6.615 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: HESSELDAHL,NELS C BRS FIELD OPS LLC Required Items and Reports(Conditions) SMITH,ALLISON B 1403 NORTH RESEARCH WAY 9345 SW MILLEN DR OREM,UT 84097 TIGARD,OR 97224 PHONE: PHONE: 855-205-2530 FAX: Total Fees: $359.69 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: }folly Va*vVPiWe.ite Permittee Signature: 0 AppliCat.io-n Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. , Building Permit AnplicationRECEIVED 20 21 Residential 'ItAR 3 0 2021 DReceived City of Tigard �{ of Zo21 Permit No.:Alf ST2021-00/Z3 14 el 13125 SW Hall Blvd.,Tigard,OR 97223 ff+ Plan Re view Phone: 503.718.2439 Fax: 503.598.1961VITY OF TIGARD Jt( 2I other Permit: DateBy: TI(iAKU Inspection Line: 503.639.4175 Date Read B /' 7aris: ia See Paget for Internet: www.tigard-or.gov BUILDINGD11/1SIOP1 �, ed/Method: G -^ Supplemental Information TYPE OF WORK REQUIRED DATA:I-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*arc based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all O Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. D 1-and 2-family dwellingValuation: $ 5,972.56 0Commercial/industrial ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder El Other. Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 9345 SW Millen Dr,Tigard, Oregon, 97224 New dwelling area: square feet City/State/ZIP: Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Nels HesselDahl Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Rooftop Solar PV Valuation: $ 4 /I 1,F L W( Existing building area: square feet 1 I New building area: square feet ® PROPERTY OWNER 0 TENANT Number of stories: Name: Nels HesselDahl Type of construction: Address:9345 SW Millen Dr,Tigard,Oregon,97224 Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( I New: ❑ APPLICANT ®CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name:BRS Field Ops, LLC Structural plan review fee(or deposit): Contact name: Tia Derbidge Address: 1403 N Research Way FLS plan review fee(if applicable): City/State/ZIP: Orem, UT 84097 Total fees due upon application: Phone:(385)482-0045 Fax: :( ) Amount received: E-mail, P 9� (� ermittin de arment blueravensolar.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name: BRS Field Ops, LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 1403 N Research Way Solar Installation Specialty Code checklist City/State/ZIP: Orem, UT 84097 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(385482-0045 Fax:(. ) State surcharge(12%of permit fee): $21.60 CCB lie.: 227185 Total fee due upon application: $201.60 Authorized signature: Jeffrey lee This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: Jeffrey Lee Date: 03/25/2021 *Fee methodology set by Tri-County Building Industry Service Board. 1:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit APPlicatiath LEC IVED FOR OFFICE USE ONLY Cl of Tigard Received Date/B : Permit#: M STZn2 I-CEO t 2 7r • 13125 SW Hall Blvd.,Tigard,OR 97223II �A� Q 20Z1 Plan Review Phone: 503.7182439 Fax: 503.598.19 U Date t : RelatedPennit#: Inspection Line: 503.639.4175 n ReadyDate/By: See Page 2 for TIGARDe Internet: www.tigard-or.gov JL'I�`1 I OF�IGARnA Notified/Method: , Supplemental Information TYPE OF W®KA`D'N�11S `rt PLAN REVIEW ❑New construction ©Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): III Demolition ❑Other: ❑Service or feeder 400 amps or more CIBuilding over three stories. where the available fault current ❑Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings. © I-and 2-family dwelling ❑Commercial/industrial less to ground,or exceeds 14,000 0 Commercial-use agricultural ❑Accessory building amps for all other installations. buildings. ❑ Multi-family E Master builder ❑Other: 0 Fire pump. ❑Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived 9345 SW Millen Dr, Tigard, Oregon, 9' ❑.4dditionofnewmotorloadof system. Joh#: Job site address: Add' or more. ❑"a","E", t-z`, t-3°', City/State/ZIP: 0 Six or more residential writs. occupancy. ❑Health-care facilities. ❑Recreational vehicle parks. Suite/bldg./apt.#: Project name: Nels HesselDahl 0 Hazardous locations. 0 Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Description I Qty. I Each I Total I * New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'I 500 sq.ft or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential 75.00 2 Rooftop Solar PV (with above sq.ft.) Limited energy,multi-family 75.00 2 residential(with above sq.ft.) El PROPERTY OWNER CI TENANT Renewable Energy 0 See Page 2 Services or feeders installation,alteration,and/or relocation Name: Nels HesselDahl 200 amps or less 100.70 2 Address: 9345 SW Millen Dr, Tigard, Oregon, 97224 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: 601 amps to 1,000 amps 301.04 2 Phone: ( ) Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 APPLICANT 0 CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name: BRS Field Ops, LLC above service or feeder fee, each branch circuit 7.42 2 Contact name: Tia Derbidge B.Fee for branch circuits without 1403 N Research Wayservice or feeder fee,first Address: branch circuit 56.18 2 City/State/ZIP: Orem, UT 84097 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( 385 t82-0045 Fax: : ( ) Each manufactured or modular 67.84 2 Entail: permitting.department@blueravensolar.com dwelling,service and/or feeder Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Bus in ess name: BRS Field Ops, LLC Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address: 1403 N Research Way 0 See Page 2 2 panel,alteration,or extension. tY Orem, UT 84097 Each additional inspection over allowable in any of the above City/State/ZIP: Additional inspection(1 hr min) 66.25/hr Phone:(385)482-0045 Fax:( ) Investigation(1 hr min) 90.00/hr Email: permitting.department@blueravensolar.com Indus al plant(lhrmin) 78.18/hr Inspections for which no fee is CCB Lic.: 227185 Electrical Lie.: C1493 Suprv.Lie.: 6394S specifically listed(ts hr min) 90.00/hr Suprv.Electrician signature,required: a *1in5 w�"te&. ELECTRICAL PERMIT FEES Subtotal: Print name: Shan Whittaker Date: 03/25/2021 0 Plan Review Required(25%of permit fee): ��/�p�� State surcharge(12%of permit fee): Authorized signature: J`"Q"`] TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Jeffrey Lee Date: 03/25/2021 days after it has been accepted as complete. a Number of inspections allowed per permit. I:1Building'Permits\ELC PemritApp_ELR_ERE.doe Rev 06/17/2015 440-4615T(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Fee for all residential systems combined: $75.00 ne etr• I Each TotalRenewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301,04 2 50.01 to 100 kva 552.26 2 Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(14 hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system: $75.00 Subtotal(Enter on Page 1): * Numbcr of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls • ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems • ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1:1Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 City of Tigard RECEIVED '' Building Division MAR 3 0 ND- 13125 SW Hall Blvd,Tigard, OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 CITY OF TIGARD TIGARD Inspection Line: 503.639.4175 BUILDING DIVISION! www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 9345 SW Millen Dr, Tigard, Oregon, 97224 City: Zip: Owner's Name: Nels HesselDahl Date: 03/25/2021 Contractor's Name: BRS Field Ops, LLC CCB #: 227185 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? p No OSSC or ORSC for design requirements. L2 Yes Wind Exposure Is the wind exposure If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes Lil Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ['] Yes the prescriptive path. above ❑ No 1 1:Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Is the construction material wood and does Yes Type of If"Yes", qualifies for the construction qualify Construction ❑ No the prescriptive path. as "conventional light frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. ElYes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? If"Yes", qualifies for Nominal lumber. 0 Yes the prescriptive path. ❑ No Is the combined weight IS Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation El layout in accordance Yes If"Yes", qualifies for with Section 305.4(3) of the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. of composition shingle. Is the roof mounted p Yes Connections of solar assembly the solar assembly connected to roof No If e li the Yp prreescsc ripaptivveies fore path.. to the roof framing or blocking ❑ directly? 2 kBuilding/Forrns/PhotoVoltaic-Checldist02-01-11.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted If the spacing falls Spacing of Minimum 24 inches solar systems P gclamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of ❑ If"Yes", qualifies for fastener? Yes the prescriptive path. ❑ No Is the roof decking of WSP min. t/z"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 !:Building!Forms/PhotoVoltaic-Checklist02-01-11.docx • Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: JinKO Solar Eagle Model Number: JKM 315M-60HL Listing Agency: CSA 4 1:Building/Forms/PhotoVoltaic-Checklist02-01-11.docx