Loading...
Plans M 21- ooOg0 10414 . \) Luck6 a- . , /— RAIN DRAIN AND OUTFALL + + + + + PROTECTION * """' BUILDING OFFSET AND �1h 3 II iP + * I I IMPERMEABLE LINER AS APPROVED . I I BY BUILDING JURISDICTION y + _ W + I I PERFORATED PIPE MANIFOLD FOR LENGTH OF FACILITY; * + + I I 4" MINIMUM. `e + + I I STRUCTURAL WALL PER + + I I BUILDING JURISDICTION + + A + W 011:1 A L , ._ .,. _e_ .,_j TOT + W j+ a d /J 6" TYP. 30" MIN. OVERFLOW TO —J F FACILITY WIDTH CONVEYANCE �s,i,1� 7 �1 11 2" MIN FREEBOARD II ) �1 I 1 a 6" MAX POND DEPTH 18" MIN GROWING MEDIUM 3" DEEP (3/4" — 1/4") CLEAN CRUSHED DRAIN ROCK �'%� 9" DEEP (1-1/2" — 3/4") • CLEAN CRUSHED DRAIN ROCK l � OVERFLOW TO �\ � X CONVEYANCE \ WATER PROOF PVC BOOT AND -- FOUNDATION DRAIN PER DESIGN CLAMP OR APPROVED EQUAL SECTION A—A NOTES: 1. PRIVATE WATER QUALITY TREATMENT LOT# 2. 30" MIN WIDTH — FACILITY LENGTH TO BE CALCULATED BASED ON INCOMING FLOWS. BOX SIZE (SF.) 3. VEGETATION: SEE PLANT LIST IN LIDA HANDBOOK. OF PLANTS 4. NO TREES OR DEEP ROOTED VEGETATION OVER PIPING. # 5. RAIN DRAINS AND OVERFLOW TO MAINTAIN MAXIMUM LINEAR TYPE OF PLANTS SEPARATION. 6. OUTFALL PROTECTION SIZED PER FLOW CALCULATIONS. 7. BUILDING JURISDICTION APPROVAL REQUIRED WHEN DEPTH OF FACILITY IS BELOW BUILDING FOOTING. SIZE OF PLANTS FLOW THROUGH PLANTER LIRA H A N D B O O K C1eanWatei Services DRAWING NO. 794 REVISED 03-16 120 Low impact Development Approaches Handbook CleanAate Services