Loading...
Plans (2) FOR OFFICE USE ONLY— SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT g # Transmittal Letter Ti t;A It n 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: Branden Taggart DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED FROM: Steve Tucker MAR 17 2021 COMPANY: Cascade Radon, Inc. CITY OF TIGIARD PHONE: 503-686-9051 BUILDING DIVC QN/ . ' EMAIL: steve@cascaderadon.com (II -I RE: 114,1 SW Hall Blvd.,Tigard, OR 97223 /'f7 G 9n — .X.)S` ) (Site Address) (Permit Number) Village at Washington Square, Building C (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Coptes'... `e:s'"...fj h...... . .s, ..4... .... . L 6ple ":... .' . "t o f .. 2 Additional set(s) of plans. Revisions: Cross section(s)and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. 2 Other(explain):Revision to show change to exterior radon systems REMARKS' his is in regards to changing the originally permitted radon systems from being Interior routed to being routed up the exterior of the building. ep ` LCjO.I' i*3VlH ' a . aa- . bfr Route Permit Techn' ian: Date: 1/4S- o2s `Z j Initials: Fees Due: Yes No Fee Description: ,/ Amount Du : 4 Y.,tvlr',y {Facea vt x{`n v krr LiY^ f $ 'f`E-i'IX f f.' , t '~ t ,r g' . , -~ pl .S ( fJlcn Y V t C - X i rc* Special ions: Reprint Permit(per PE): I Yes No ❑Done Applicant Notified: Date: L/l//a( Initials:i 6' ' I:1Building\Forms\TransmittalLetter-Revisions_073120.doc meC a.0 - oo 8a • ti`aw- OFFICE COPY 3-a.s•-- a-) RECEIVED pvp TP REVISION FIAR 17 2ort Active Sub-Soil / Sub-Slab Depressurization (ASD) CITY OFTIGARD BUILDING DIVISION OFFICE COPY General Installation Notes: ' I 4. 1. System(s)to be Active Sub-Soil/Sub-Slab Depressurization (ASD). 7/2I n 2. All installations to comply with EPA protocols. 3. Exhaust fan(s)to be located so to be assessable for installation, maintenance, and future replacement, and in a vertical run of vent pipe. 4. More than one system may be needed for the building. 5. Typical fan specs: Continuously running electric, inline duct exhaust fan(s)shall be used. 21W-150W,60 hz, 115V, 1.5 amps,60 cycle. 6. Vent piping shall be schedule-40 PVC or ABS,with a minimum 3-inch diameter. 7. Vent termination to be a minimum of 12 inches above the roof line/eave, as well as 2 feet above and/or 10 horizontally from any intake into living space. 8. All vent pipe joints/connections to be sealed and air-tight. 9. Vent pipe shall not have low points, and shall be sloped so as to allow condensate within pipes to flow back to the sub-soil suction point(s). 10. Electrical disconnect for any exhaust fan shall be located within sight of the fan unit. Electrical power supply for any fan unit to be drawn from un-switched building power. 11. Provide proper flashing at all roof penetrations. 12. When reasonably possible, a manometer(air pressure gauge)shall be Installed on or near the negative side of the vent system, and shall be a visible and/or audible mechanism that is simple to read and interpret. 13. All penetrations through concrete slab flooring, or concrete perimeter foundations,whall be sealed as is reasonable. 14. All vent pipes penetrating through fire-rated walls and ceilings shall have a properly rated fire collar and/or equivalent. 15. All system components to be adequately secured: vent pipe every 8 feet vertically(min), and every 4 feet horizontally(min). 16. Systems shall be clearly labeled "Radon Reduction System" or the like. System shall also be labeled as to: a. Dated activated. b. Installers name. c. Information on how to contact installer. ROOF SCREENED TERMINUS FLASH IF ROOF ;_; PENETRATION `z. IIP 0 OPTION:AROUND EVE r iy SCHEDULE 40 PIPE. 3"-4"DIA.TYP. 5 j iy INSIDE OUTSIDE PIPE STRAP @ 8'-0" a .. O.C.MAX. FLEXIBLE COUPLING EXTERIOR RATED FAN. CSLAB 110 V W(DISCONNECT SLAB i irstai""fir:. 1j4�er ��. SCREENED — SEAL PENETRATION INTAKE Y; a-s-,rss CONC. FOOTING -. - GRADE — I —III III—III III: -I 11 1—I 11- 1-1 —I I 11= Ti —iii=iir- SUB-SOIL DEPRESSURIZATION RADON MITIGATION SYSTEM THROUGH-FOOTING SUCTIUON POINT ('SAILOR PIPE") - NTS PL I 7 I 10'0" I I 0 Q I I I I I I 0 0 20'0" BUILDING A I I4 ► I I i t I PARKING I I HALL BLVD I I BUILD VG C 4 ► I 70'6" • 0 I I I I I COMM BLDG I I 0I-- I I BUILDING B 0 * I PL RADON MITIGATION NORTH LEGEND: SITE PLAN 11157 SW HALL BLVD. ♦ 0 INTERIOR ROUTED SC,%I_L: 4- Li:'O"�I TIGARD, OR 97223 I RADON VENT SYSTEMS Q EXTERIOR MOUNTED RADON SYSTEMS Installation and Operation Manual Manuel d'installation et d'operation Rn2EC / Rn4EC Inline EC Radon Fan • Ventilateur pour radon en ligne EC MITI i TIE Mg IAaflC1 MATE M TN 11112111eATt1 1•ht•.Ran Frn Fin 1 a Fine Hadan Fen Fin 1 pc Oman-an and Instalannn Manr-f 1 pc LOW-Cacnngs.2 pcs Oponitgn and eintaltr[or M.rud, pc MIet3 AAA LA MITE IAe2EC1 PIt S MM IA MfiE IYAECI K+edetor par radon an tigru FL, 1 pc LU•d IWtar pat'rsy]n en lyre Rn.1 pc Ihenafi dirr:inaeracn 1 do Cu:Magas LON1^• 2(inn 71<+T 1.4rasl drntapa[1in 1 pc neiEc A.ac REGISTER° THIS PRODUCT TO ❑ . ❑ LNCREASE YOUR PRODUCT f } 1 WARRANTY BY AN EXTRA YEAR reaustration.fantech.ao 0 'Al • • �'• •In USA orev iRMlIcal I Customer Support: ° '1 fa n t e c h 5t+[Crrt teClrlgJ:K ur ri vre 8 L. •erdele Melted States Tat 0007A71762 ITaeede Tel EGO 5653578 a syscem.:r con:pdiri a ,1;0- — — ---- —— —.SO- ._ —,wl1,� ,� ■ J1 III .�I al Ins Imo' °BUILDING C WEST ELEVATION °BUILDING C SOUTH ELEVATION mre w.rs xw:E:1,. iv i! lei -.Milli !hip .. MI [a PT III 11i _ °BUILDING C NORTH ELEVATION r-)B8UILDING C EAST ELEVATION i lM"�a ea - NM