Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
'11111IMP"' Vt7S202( -OC7D�5 l,,L-o-O DPW opp t.r�l P POTTER IPA-100 The Symbol of Protection Fire Alarm Control Panel Features • 127 addresses available on this analog addressable system r • Additional system capacity achieved via multi-point SLC modules r RECEIVED • 99 software zones • NFPA 72 Compliant Smoke Sensitivity Test Built-In • System Operates as Class A or Class B for SLC,P-Link and NACs JAN 2 0 2011 RARER • 5 Amp Power Supply,Expandable to 310 amps • 2 NACS,Regulated,Rated at 3 Amps each,expandable to 188 CM OF TIGARD • 2 Input/Output(I/O)Circuits for system flexibility rated at l Amp eacl a$OtJ t I ideal for manual release and abort UIVhl1�J�� • Strobe Synchronization and System Wide Sync for Potter/AMSECO®, • Gentex®,Cooper Wheelock®and System Sensor®strobes • Dedicated Alarm,Supervisory and Trouble Relays • 4,000 Event History Buffer • Cabinet will house up to 18 AI-1 batteries • Optional two line DACT with UD-1000 that can report General,Zone or (211 Point Information • Built in IP Communicator LISTED • Ethernet Port for Programming and Network Connectivity • E-Mail System Status,Reports and Event Information • Product includes 5 year warranty Description Technical Specifications The IPA-l00 is an analog/addressable releasing fire alarm system with a Dimensions 16"W x 17"H x 3 7/a"D total system capacity of 127 addresses.Additional capacity on the system 3.0 Amps @ 120 VAC 50/60 HZ is achieved using multi-point SLC modules. The control panel utilizes AC Mains the exclusive Potter protocol that includes a complete line of sensors and 2.0 Amps @ 240 VAC 50/60 HZ modules. Each SLC may be comprised of any combination of smoke 16 gauge cold rolled steel with removable sensor, heat detectors or modules and allows for a total of 50 ohms of Enclosure locked door with Lexan viewing window impedance and may use any wire compliant with the National Electrical Standby Current-130 mA Code(NEC). Alarm Current-200 mA The IPA-100 has a 5 Amp power supply with two Notification Appliance • 5 Amps power for NACs,UO,and P-Link Circuits(NACs)and two Input/Output(I/O)circuits.The NACs are rated at Battery • 3 Amps per NAC,regulated 3 Amps each and the I/Os are rated at lAmp each.Each output is regulated • 1 Amp per I/O circuit,regulated and power limited.In addition,each output is uniquely programmable and • Battery Charger range 8-55 Ah may be configured for steady signal, strobe synchronization, constant • Battery Charger voltage 27.3 VDC • power, door holder power, or releasing. The strobe synchronization P-Link maximum current of 1 Amp includes Potter/AMSECO,Gentex,System Sensor and Cooper/Wheelock Temperature and 32°to 120°(0°C to 49°C)with a maximum and with the exclusive Quadrasync each output may have a unique brand Humidity Range humidity of 93%non-condensing. and all strobes will flash together.The I/Os are designed for inputs such as • NFPA 12, 12A, 13, 15, 16, 17, 17A,70, manual release stations and abort switches that will not require polling and 72,750,and 2001 react nearly instantaneously. • ANSUUL 864-Local(L),Remote Sta- The IPA-l00 is listed for releasing of fire suppression systems. The tion(RS),Central Station(CS),Propriety software allows cross zones,counting zones,and timers for suppression. (PPU),Auxiliary(AUX).Type of Service: The system is capable of multiple release outputs across multiple hazards. Standards Automatic(A),Manual(M),Water flow In addition,the PSN-1000 may be used to extend releasing capability. (WF)Sprinkler Supervisory(SS)Type of The NACs may be expanded using the PSN-1000 series intelligent power Signaling:Digital Alarm Communicator supplies.Each PSN-1000 adds another 10 Amps of power,2 additional (DAC),March Time(March),Non Coded input circuits and the IPA-100 will support up to 31 power supplies.The (NC),Reverse Polarity(Rev Pol),Other system will synchronize the strobes system wide. In addition,the PSN- Technologies(OT) 1000E has space to allow the installation of up to six loop expansion cards. • IBC 2000,2003,2006,2009,2012 The cards mount on a stacker bracket that allows access to all SLC circuit connections. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830101-REV A • 03/16 PAGE I OF 4 71.1r P POTTER IPA-100 The Symbol of Protection Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 127 addressable devices or modules in any combination.The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PAD100-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PAD100-PHD Combination Analog Photo Electric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135°Fahrenheit heat detector. PAD100-HD Analog Fixed Temperature Heat Detector that is selectable from 135°F to 185°F. PAD100-DUCTR Addressable Duct Smoke Detector with Form C Relay. PAD100-DUCT Addressable Duct Smoke Detector. PAD100-6B 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD 100-4B 4"round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD 100-IB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD100-RB Addressable Relay Base that contains one relay controlled by the SLC.Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. PAD100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call. PAD100-CD Addressable CO gas detector. PAD100-DD Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. Modules Device Description PAD100-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD100-PSSA Single Action Addressable Pull Station. PAD100-PSDA Dual Action Addressable Pull Station. PAD100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4"square electrical box. PAD100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD100-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel.Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC.Also provides two contact inputs. PAD100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD100-IM Isolater Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD100-RM Relay Module that provides one form C relay controlled by the control panel.Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. PAD100-LED Module provides a single addressable LED that is controlled by the control panel. PAD100-SM Speaker Module provides switching for two audio channels. PAD100-LEDK Addressable LED and key switch that mounts in a single gang box. PAD100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. PAD100-OROI One Relay One Input Module provides one form C relay and one input.The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830101-REVA • 03/16 PAGE2OF4 P POTTER IPA-100 The Symbol of Protection Fire Alarm Control Panel SLC Features RA-6075R—2 x 16 LCD annunciator with a key pad in a locked The Potter protocol is a digital protocol with a proven design for metal enclosure. reliability and noise immunity.The system does not require special RA-6500R(F)—4 x 40 LCD annunciator with a key pad in a locked cable or conductors for connection of the Signaling Line Circuit metal enclosure.Flush mount version available. as long as the cable is compliant with NFPA 70 and NFPA 72. LED-16(F)—16 LED annunciator with common indicators in a The system allows for Class A or Class B installations as well as locked metal enclosure.Flush mount version available. "T-Taps",with a max wiring distance of 10,000 Ft. PSN-1000(E)—10 amp,remote intelligent power supply with 6 NACs,2 UOs and a P-Link repeater.This panel is listed in Sensor Features conjunction with the IPA-100 as releasing circuits. The sensors through the fire alarm control panel provide a real CA-6500—Class A convertor that converts the SLC,NACs and time status as to the condition of the system.The smoke detector P-Link connection sensitivity,heat detector temperature level and drift compensation UD-1000—UL listed,Dual line telephone alarm communicator are all programmable options.The system also allows for a day/night DRV-50—LED driver expander,used to connect up to 50 LEDs in a mode where the panel automatically adjusts the sensitivity depending graphic display on the time of day.To assist in the reduction of false alarms,the FCB-1000—Fire communication bridge,provides remote mounting smoke detectors also have a maintenance warning that sends a trouble of the Ethernet connection signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. FIB-1000—Fiber interface module,used to extend P-Link to multi- mode fiber(2 required) User Interface RLY-5—Relay module,provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC The fire alarm control panel has a 2 x 16 LCD display to provide SPG-1000—Serial parallel gateway,allows for the connection to a information to the system status.The keypad has navigation keys to allow manipulation of the Menu on board the panel.The panel is serial or parallel printer shipped standard with the following LEDs: The FIB-1000,FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. • AC Power-Green MC-1000 Multi-Connect allows up to sixty-three IPA series panels to • Alarm-Red share a single reporting technology. • Earth Fault-Amber AE-2—Two card expansion cabinet AE-8—Eight card expansion cabinet • Supervisory-Amber • Silenced-Amber AE-14—Fourteen card expansion cabinet • Trouble-Amber Ethernet/I.P. Connection • Pre-Release-Amber The IPA-100 is shipped standard with an Ethernet connection. • Release-Red This connection is the programming port and may be connected The common buttons include a Silence,Reset,Acknowledge,and to a building Wide Area Network(WAN)or Local Area Network Drill.All of the buttons are accessible once the locked door is (LAN). Once connected to the Internet,the panel may be selectively opened. programmed to e-mail alarm conditions,trouble conditions, supervisory conditions,test,Event History and detector status.An P-Link e-mail may be sent to the panel and the panel will e-mail the event history,detector status,configuration file or server status to an The IPA-100 has a proprietary communication protocol that authorized E-mail account.In addition,reminders may be set to send communicates through a RS-485 connection to field devices.Up an e-mail for service,testing or other conditions. to 64 devices may be connected to a single P-Link connection.The P-Link includes the communication terminals and regulated 24 VDC In addition,the Ethernet connection is UL listed as an IP connection for the field devices.The field devices may be any of the communicator.The IP communicator is listed to report to the UL following: listed Sur-Gard III IP receiver.The IP communicator replaces the PAD100-SLCE-Analog/Addressable loop expansion module traditional less reliable alarm communicator transmitter that utilized telephone lines.The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830101-REV A • 03/16 PAGE 3 OF 4 • L P POTTER IPA-100 The Symbol of Protection Fire Alarm Control Panel Dimensions 0 o 1 TOP • . DEPTH=3.75" e o e lj LI DOOR= 16.07" BACKBOX=15.77 DEPTH=3.84" • • co� n 8 ( 0 © I II 0. II 0 OY oq m LEFT SIDE RIGHT SIDE BOTTOM • G`NG 0593-1 Compatible Releasing Devices Note: For releasing applications please order the Potter EOLD Ordering Information (3005012)for circuits connected to a releasing solenoid or actuator. Model Description Stock No. Brand Description IPA-100 Fire Alarm Releasing Control Panel 3992715 73218BN4UNLVNOC1I2CZ Skinner 73212BN4TNLVNOC322C2 Victaulic 753-E Series Mini Max MX123&MX200 w/8876677&889323 Viking 11591, 11601, 11602, 13843,& 13844 TLX PA0036 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830101-REVA • 03/16 PAGE 4 OF 4 P POTTER PSN-1000(E) The Symbol of Protection POWER EXPANDER Features • 10 Amp Power Supply • 3 Amps,regulated per NAC • 6 NACs Class B or 3 NACs Class A • 2 dry contact inputs • Fully programmable and monitored through control panel • Isolated P-Link repeater connection,Class A or B • Up to 31 power supplies per control panel with system wide sync • Quadrasync feature synchronizes strobes from Potter/AMSECO, Gentex,Cooper-Wheelock and System Sensor. PJTTEP PSN-1 000 • Compatible with all Potter PFC-6000 series fire alarm control panels. ` zls 1mbd f p n Power Supply —�• Electrical Specs • 120/240 VAC Input at 50/60 HZ • 5.1 Amps/3.0 Amps max draw • Standby Current 60 mA • Alarm Current 200 mA k S2930 7165-0328: 0198 Product includes a 5 year warranty Description The PSN-1000 series is a UL listed intelligent 10 amp notification power supply and P-Link(RS-485)repeater.The power supply connects to the P-Link bus from the control panel and is operated and supervised from the panel.The power supply may be installed 6,500 feet from the control panel.The PSN-1000 then repeats the P-Link communication for another 6,500 feet. The power supply has six(6)Class B or three(3)Class A power outputs.Each output is regulated and power limited with a 3 Amp maximum rating.In addition,the PSN-1000 has two(2)programmable dry contact inputs.The dry contact inputs are Class B,supervised inputs. The power supply operates on either 120 or 220 VAC power and has a regulated 24 VDC output.In addition,the panel can charge up to 55 AH batteries and will house 18 AH batteries.The cabinet is constructed out of 18 gauge cold rolled steel with a durable red powder coat finish.A standard Potter key lock is provided for securing the door.Electrical conduit knockouts are provided on the sides and top providing installers with multiple options for installing conduits and providing proper power separations. The PSN-1000 is a self contained intelligent power supply/P-Link repeater complete with cabinet.The PSN-1000E is the intelligent power supply/P-Link repeater with additional cabinet room for the exclusive Stacker Bracket for SLCE-127 loop expanders.Both cabinets include space for 18 AH batteries. The power supplies are programmed and controlled through the main control panel P-Link bus.The panel displays any troubles or off normal conditions of the power supply and the events are stored in the panel history buffer. Each output can be independently configured to provide one of four synchronization patterns,constant power,ANSI temporal Code 3 or Door Holder power.The panel can be configured to synchronize Potter/AMSECO®,Gentex®,Cooper Wheelock®and System Sensor®. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830032-REV A PAGE I OF 2 05/12 P POTTER PSN-1000(E) ® The S mho!of Protection POWER EXPANDER 18.91" 17.60" 4 0 0 _ TOP o 1 4.41" 3.75" ' - DEPTH b • � d . b 0 0 N 0 cv b b 0 0 LEFT SIDE RIGHT SIDE BOTTOM 0 Dimensional drawings showing the cabinet in all three planes. Knock out locations. g . PRINTED IN USA MFG.#8830032-REV A PAGE 2 OF 2 05/12 P ` POTTER PAD100-DUCT The Symbol of Protection Analog Addressable Duct Detector Features • Detects smoke in building HVAC ducts • Ships complete with housing and detector • Compatible with addressable IPA series panels • SLC in and out wire terminals • SLC Class A,Class X&Class N.0 • Installation without removing the detector 4 • • Listed Air Velocity of 100 to 4,000 ft/minute N r • No screens or filters in housing • Durable plastic enclosure and clear cover • Integrated cover tamper switch • Utilizes simple snap in sampling tubes STN series • Product includes a 5 year warranty LISTED Description Technical Specifications The PAD 100-DUCT is designed and built to meet all local Duct Detector Model requirements, as well as the NFPA regulations regarding duct smoke Number PAD 100-DUCT detectors.Air sampling is accomplished by two tubes which protrude Operating Voltage 24 VDC into the duct.An exhaust tube of one standard length(7")is supplied in the installation kit with the smoke duct unit. Once the duct width Current Draw 300 µA has been determined the air intake sampling tubes must be ordered. Detector Head Model PAD 100-DD Sampling tubes are supplied in three standard lengths: 2.5 ft., 5 ft., Detector Head Type Photoelectric and 10 ft. and cut to size to fit the duct. Mounting the duct smoke unit is accomplished by the use of a template and 2 sheet metal Sensitivity Test Method Self diagnostic test screws, which are provided. Mounting can be achieved without the Air Velocity 100 to 4000 ft./min removal of the clear cover which is secured by 4 capture screws. Ambient Temperature 32°F to 120°F(0°C to 49°C) Application Humidity 10%to 85%Relative humidity(non- condensing) The Potter Electric PAD 100-DUCT duct smoke detector provides Housing Material Plastic backbox,clear plastic cover early detection of smoke and products of combustion present in air moving through HVAC ducts in commercial, industrial Finish Gray backbox with clear cover and residential applications. The PAD 100-DUCT is compatible Dimensions 13 I/2"L x 4 1/2"W x 2 1/4"H with the IPA series addressable fire alarm control panels. Maximum Net Weight 2 lbs. Sampling Tubes 2.5 ft.,5 ft.,or 10 ft. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830099-REV A • 03/16 PAGE 1 OF 2 a P POTTER PAD1 00-DUCT R The Symbol of Protection Analog Addressable Duct Detector Engineering Specifications Air duct smoke detectors shall be Potter Electric PAD 100-DUCT Series.The detectors shall be listed by Underwriters Laboratories per UL 268A.The detectors shall operate at air velocities from 100 feet per minute to 4000 feet per minute.The duct detector housings shall be of plastic construction - and complete mechanical installation may be performed without removal of detector cover.Visual indication of alarm and power must be provided on detector front.Detector heads shall not require additional filters or screens which must be maintained.The housing shall contain a detector base and PAD 100-DD duct smoke detector head.Terminal connections shall be of the screw type and be a minimum of# 12 screw.All wiring must comply with local codes and regulations.Detector shall use the SIN series of sampling tubes. Wiring Diagram Fig I 0 ) ° ra -: @ rr: 710 +SLC ,� 7i� 11M-SLC TO NEXT MODULE / _ O + �1 +SLC 1W FROM FACP or •/, ir 11111111 ' -SLC PREVIOUS MODULE 0 ILF-='- o • im no Ordering Information Model Description Stock No. PAD 100-DUCT Analog Addressable Duct Detector 3992713 Model Description Stock No. STN-2.5 2.5'Sampling Tube 1000274 STN-5 5'Sampling Tube 1000275 STN-10 10'Sampling Tube 1000276 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830099-REV A • 03/16 PAGE 2 OF 2 P POTTER PAD 100-H D The Symbol of Protection Heat Detector Features • Selectable Rate of Rise and/or Fixed Heat Detector • Low profile • Reliable detection technology • LED Alarm Indicator • Ambient temperature listing of 32°F to 150°F• Simple DIP switch address setting,no programming tool required rj • Product includes a 5 year warranty LISTED Description Technical Specifications The PAD100-HD is a listed Analog Addressable rate of rise and/or Operating Voltage 24 VDC fixed temperature heat sensor compatible with any fire alarm control panel that has the Potter Addressable Device(PAD)protocol.The heat Alarm indicator 1 LED sensing portion utilizes a proven thermistor for accurate and reliable Alarm set-point range 135 to 185°F/57 to 85°C heat detection. The sensor and base (not included) are made of a Installation temperature durable plastic in an off white to blend in with the ceiling. range 32 to 150°F/ 0 to 66°C The PAD100-HD is UL listed with a selectable fixed temperature Operating relative ° point from 135° to 185° Fahrenheit and can be used for rate of rise 0%to 93%(Non-condensing) humidity range applications. See detector spacing limitations below. This flexibility allows the installer to cover a wide variety of applications with a single Start-up time Max. 1 sec. unit. Maximum number of 127 The PADI00-HD and the control panel communicate over a proven addresses per loop and robust digital communication path and the system analyzes the Maximum number of information at the particular device.The total polling speed is less than lighted indicators in 30 five(5)seconds,well under the UL requirements. alarm per loop The sensor is compatible with any of the PAD series sensor bases and Color Eggshell White simply twists on.The PAD100-HD is addressed using DIP switches Weight(without base) 82g(2.89 oz) in the rear of the sensor and can be easily programmed in the field without special tools. Dimensions(without Height: 1.94 in(49mm) base) Diameter 3.93 in(100mm) Setting the Address Each addressable device on the SLC loop must have a unique address from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device.Verify the following: 1. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830110-REV A • 03/16 PAGE 1 OF 2 P POTTER PAD 100-H D The Symbol of Protection Heat Detector Operation The PAD100-HD is an analog addressable sensor that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled.The LED flashes every time the unit is polled and will flash at a fast rate if the unit is in an active status.The polling LED can be turned off if desired for less conspicuous operation. The PAD100-HD with the PAD100-4DB or PAD100-6DB has a low profile to blend into the surrounding environment.The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on,the PAD100-HD will operate even though the LED will not . illuminate. Spacing The ANSI/UL listed spacing limitations of PAD100-HD smooth ceiling are dependent on alarm set point. Alarm Set-Point Rate of Rise Spacing Fixed Temperature Spacing 135°F to 160°F Max.70 ft. Max.70 ft. (57°C to 71°C) 161°F to 174°F Max.60 ft. Max.60 ft. (72°C to 79°C) 175°F to 185°F Max. 15 ft. Max. 15 ft. (80°C to 85°C) Compatible Bases All bases will mount on a single gang,double gang,octagon,4"square or mud ring electrical box. Device Description Stock No. PAD 100-4DB 4"Standard Base 3992731 PAD100-6DB 6"Standard Base 3992732 PAD 100-1B 6"base with an isolator module included. 3992730 PAD100-RB 6"base with one Form-C relay contact. 2A @ 30VDC,0.5A @ 125VAC 3992728 PAD100-SB 6"base with sounder module included. Sound pattern is provided from external source. 3992729 Ordering Information Model Description Stock No. PAD100-HD Fixed Temperature Heat Sensor 3992735 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830110-REVA • 03/16 PAGE2OF2 P POTTER PAD 100-P D The Symbol of Protection Photoelectric Smoke Sensor Features "'' • Low profile,less than 2 inches with the base 6' • Wide selectable sensitivity range of 1.0 to 3.7%/foot • Sensor communicates sensitivity to control panel • UL listed smoke calibration and sensitivity - • Optional locking tab to prevent unwanted removal • Simple DIP switch address setting,no programming tool required • LED alarm indicator • Product includes a 5 year warranty 0 LISTED Description Technical Specifications The Photoelectric Smoke Sensor is a listed Analog Addressable smoke Operating Voltage 24 VDC sensor compatible with fire alarm control panels that utilize the Potter Addressable Device(PAD)protocol.The PAD100-PD is a low profile Alarm indicator 1 LED smoke sensor with a wide sensitivity range.The sensor and base(not Alarm set-point range 1.0 to 3.7%/ft 3.6-12%/m included)are made of a durable plastic in an off-white color to blend Installation temperature in with the ceiling. 32 to 120°F/ 0 to 49°C range The PAD100-PD has a sensitivity range of 1.0 to 3.7%per foot and Operating relative o 0 is UL. The PAD100-PD features drift compensation and has built in 0%to 93/a(Non-condensing) humidity range dirty detector warning as well as. The PAD100-PD and the control panel communicate over a proven and robust digital communication Start-up time Max. 1 sec. path and the system analyzes the information at the particular device. Maximum number of 127 The total polling speed is less than five(5)seconds,well under the UL addresses per loop requirements. Maximum number of The sensor is compatible with any of the PAD series sensor bases and lighted indicators in 30 simply twists on. The PAD100-PD is addressed using DIP switches alarm per loop. in the rear of the sensor and can be easily programmed in the field Color Eggshell White without special tools. Weight(without base) 101g(3.56oz) Setting the Address Dimensions(without Height: 1.35 in(34mm) Each addressable device on the SLC loop must have a unique address base) Diameter:3.93 in(100 mm) from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device.Verify the following: 1. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830108-REV A • 03/16 PAGE 1 OF 2 P POTTER PADI 00-PD The Symbol of Protection Photoelectric Smoke Sensor Air Velocity Ratings The PAD100-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneously.If the system already has 30 LEDs on,the PAD 100-PD will operate even - though the LED may not illuminate. Operation The PAD100-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled.The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status.The polling LED can be turned off if desired for less conspicuous operation. The PAD100-PD with the PAD100-4DB or PAD100-6DB has a low profile of less than two(2)inches to blend into the surrounding environment.The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PAD100-PD and the compatible control panel work in tandem to keep the sensitivity consistent.As the sensor is installed over time,the sensor compensates for the dirt in the unit until it is out of range.At that time,the panel will indicate a dirty sensor.The sensor will then have to be cleaned or replaced. The PAD100-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. NOTE:As required by NFPA,do not install the sensors until all construction is complete and the work area has been thoroughly cleaned.If the sensors have been installed in a construction environment,they should be cleaned or replaced before the system is placed into service. Spacing The PAD 100-PD is UL listed with a recommended maximum spacing of 30 feet.Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang,double gang,octagon,4"square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4"Standard Base 3992731 PAD 100-6DB 6"Standard Base 3992732 PAD 100-IB 6"base with an isolator module included. 3992730 PAD100-RB 6"base with one Form-C relay contact. 2A @ 30VDC,0.5A @ 125VAC 3992728 • PAD 100-SB 6"base with sounder module included.Sound pattern is provided from external source. 3992729 Ordering Information Model Description Stock No. PAD100-PD Photoelectric Smoke Sensor 3992733 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830108-REV A • 03/16 PAGE 2 OF 2 P POTTER PAD100-RM The Symbol of Protection Relay Module Features • One(1)Form C relay contact • SLC Class A,Class X&Class B • Mounts in a standard 4"or double gang box 0061 • Wiring terminals accessible when mounted in box " • All wiring terminals accept 22 to 12 AWG r 4; • Product includes a 5 year warranty .y. PPmW R (1211 LISTED Description Technical Specifications The PAD100-RM uses one(1) SLC loop address to provide one (1) Operating Voltage 24.0V Form C relay contact. The module mounts on either a 4" square or double gang box.The PAD100-RM includes one red LED to indicate Max SLC Standby 240µA the module's status. In normal condition, the LED flashes when the Current device is being polled by the control panel. Max SLC Alarm 240µA Current Application Relay Contacts 2A@30VDC,0.5A@125VAC The PAD 100-RM is compatible with Potter's IPA series addressable OOperrae ing Temperature 32 to 120°F(0 to 49°C) angfire alarm control panels. The PAD100-RM is an interface module providing one(1)Form C relay contact. Operating Humidity 0 to 93%(non-condensing) Setting the Address Max no.of Module Per 127 units Each addressable SLC device must be assigned an address. The Loop address is set using the DIP switch located on the PAD100-RM.The 4.1T'(106mm)L x 4.17" Dimensions PAD100-RM uses a single device address to identify relay contacts. (106mm)W x 1.14"(29mm)D Before connecting a device to the SLC loop, take the following Mounting Options Standard 4"Square or precautions to prevent potential damage to the panel or device: Double Gang Box 1. Power to the device is removed. Shipping Weight 0.6 lbs 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830084 -REVA • 03/16 PAGE I OF 2 P POTTER PAD100-RM The Symbol of Protection Relay Module Installation Using Compatible Electrical Box Fig I Ark 14112I I 0 11114411111 , O Ifil)1 Wiring Diagram PADI00-RMRelay Circuit Fig 2 (lV� CD FROM FACPOR 't® 0 sy PREVIOUS MODULE \ ��liiiai� • TO NEXT MODULE I�[�I ,Etc � ,�rro 17�1, ONE(1)FORM C l L l U RELAY CONTACTS O 0 F : O 0 0 0 O 0 0 0 0 0 0 0 ®pora r CD 0 CD NOTICE It is possible that the internal relay in the PAD100-RM may be shipped in the non-normal/activated state.To ensure that the internal relay is set to the normal state,connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output. Ordering Information Model Description Stock No. PAD100-RM Relay Module 3992705 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830084-REV A • 03/16 PAGE 2 OF 2 P P O TTFR PAD100-SIM The Symbol of Protection Single Input Module Features • One(1)Class B monitoring input • SLC Class A,Class X&Class B • Mounts in a standard 4"or double gang box 0 • Wiring terminals accessible when mounted in box ' • All wiring terminals accept 22 to 12 AWG • Product includes a 5 year warranty NOTE:This addressable module does not support 2-wire smoke ®POTTER detectors. ,�.. "`""� Description Technical Specifications The PAD100-SIM uses one(1)SLC loop addresses when monitoring Operating Voltage 24.0V one(1)Class B circuit. The module mounts on either a 4" square or double gang box.The module is capable of monitoring one(1)Class Max SLC Standby 240µA B circuit. The PAD100-SIM includes one red LED to indicate the Current module's status.In normal condition,the LED flashes when the device Max SLC Alarm 240µA is being polled by the control panel.When the input is activated,the Current LED will flash at a fast rate. Max Wiring Resistance 100 it of IDC Application Max Wiring 1 P Capacitance of IDC p The PAD 100-SIM is compatible with Potter's IPA series addressable fire alarm control panels. The PADI00-SIM is an interface module EOL Resistor 5.1K S2 used to monitor dry contact devices such as sprinkler waterf ow,valve OOper ing Temperature 32 to 120°F(0 to 49°C) tamper switches,or conventional pull stations.The module is capable of monitoring one Class B circuit. Range mg Humidity 0 to 93%(non-condensing) Setting the Address Max no.of Module Per 127 units Each addressable SLC device must be assigned an address.The address Loop is set using the DIP switch located on the PADI00-SIM. Dimensions 4.17"(106mm)L x 4.17" Before connecting a device to the SLC loop, take the following (106mm)W x 1.14"(29mm)D precautions to prevent potential damage to the panel or device: Mounting Options Standard 4"Square or Double Gang Box 1. Power to the device is removed. 2. Field wiring is correctly installed. Shipping Weight 0.61bs 3. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830083-REV A • 03/16 PAGE I OF 2 P POTTER PAD100-SIM ® The Symbol of Protection Single Input Module Installation Using Compatible Electrical Box Fig I 31-• IT— >> lam,r 1 t 0 l O 0 Itik e x. H J 0 -1I o Wiring Diagram PADl00-SIM With Class B Circuit Fig 2 CD FROM FACP OR ® � PREVIOUS MODULE \ O IH'PI \ / °TO NEXT MODULE 't \ml --'J ° 711 J ° END-OF-LINE RESISTOR Gt ° 5.1KOHM W ° ° Part#3005013 �� _ ®,� _ r '' a ® a Ordering Information Model Description Stock No. PAD 100-SIM Single Input Module 3992704 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830083-REV A • 03/16 PAGE 2 OF 2 P POTTER U D-1000 ® The Symbol of Protection Digital Alarm Communicator Features • Allows for communication to Monitoring Station 0 • Communicates using SIA-DCS or Ademco Contact ID Protocols rr, '.'�yr, • For use with 6000 series and P series Addressable Panels .. . • Status LEDs indicate operation of DACT card ti�6 91T: w ` - • Installs with ease behind main panel LCD display via User Interface bracket N.', ,"r,,` .,yea • Device address is set by dipswitches located on DACT card ._ , , , : r: • Installation materials including 4 pin connector and screw are supplied y a I. 1111141 with DACT card g s :jlr F ils Ilk tf a',!-:,..-- traw • ® ( ) LISTED S735 7165-0328:0195 Description The UD-1000 Digital Alarm Communicator Transmitter (DACT) Technical Specifications provides for up to two (2) phone lines for communication to a monitoring station. The UD-1000 communicates using the SIA- Operating Voltage 22.0-24.0V DCS or Ademco Contact ID protocols. When enabled, the DACT Standby Current 16mA automatically monitors each phone line or voltage and has the ability to seize the line and connect with a remote receiver. Once the Alarm Current 23mA communication is complete,the DACT will hang up. Max UD-1000s per panel 1 The DACT is provided with an RJ-11 jack for each phone line and a Dimensions 4"W*6"H* 1-5/8"D RI-1 1 to RJ-33 cord.In order for the DACT to work properly,it must Operating Tempuratures 0°C-49°C(32°F-120°F) be installed on a plain old telephone service(POTS)line or equivalent deemed by the authority having jurisdiction. The DACT must be Operating Humidity Range 10/a-93%@ 30°C(86°F) installed before any other equipment to ensure it can seize the phone (non-condensing) line. Mounting Options In FACP Behind keypad Phone lines are high voltage and should be run in a separate conduit Shipping Weight 0.47 lbs from other circuits.The wire conductors connecting the DACT to the phone system should be 26 AWG or larger. Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com 8830048-REV A • 1/15 PAGE 1 OF 2 P POTTER U D-1000 ® The Symbol of Protection Digital Alarm Communicator UD-1 000 DACT Installation on UD-1000 DACT Installation on PFC-6030/6075R PFC-6800/6200 Fig 1 Fig 2 II 'I Iii �...:q.a'., if I alb l ° _____ II \�:, 4' [1211 CiT3 Png<:C=1: \\-1.7'."." ❑ ifS9SC2r3 ❑ ° ❑ . r�r�iI Q 8 1 IIa � air__ j II �O° — ��l.1 �1. "I ■N • � ■ �IR� VIR - --:'' 1. Screw I UD1000(ACT Ian 0(} !FRG Slides in guides under main board. '° v a• ° mVGA59}I3A ®�II W� il�j� 0 1 f 1t __,_._:,7___,______.iiMis I 1.17------------1 ; Iv llifil 17 4 e ' IFFILT,-7 E j_ E,.. 1 P Connector s<-- ij, •o-,.., on PFC-6075 main board FRD 1s1., �p o ®®®• P Connector 01 ail®® _�� on PFC-6800 �. main board NOTICE rrot,-----4-----4'1 Install in accordance with compatible fire alarm control panel mR A ;• _`mominstallation manual _— a sun Installation The UD-1000 DACT is connected to the control panel using the provided four-wire cable connection(P/N 5210514)between P4 and UD-1000 Pl.The connection is power limited and supervised. 1. Power system down. 2. Slide the UD-1000 into the card guides located under the User Interface bracket. 3. Secure the UD-1000 to the User Interface bracket using the provided#6-32x3/8"screw 4. Install the provided four-wire conductor jumper between UD-1000 PI and P4. Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com Ise sou l:zoos!DESIGNING,MANUFACTURING, CERTIFIED &DISTRIBUTING QUALITY SYSTEMS 8830048-REVA • 1/15 PAGE 2 OF 2