Loading...
Report 909_20ZI-O0C510 i//30 cam« i 5c COMcheck Software Version COMcheckWeb inflr ‘ifi Envelope Compliance Certificate RECEWED Project Information lAN 2 8 202 Energy Code: 90.1 (2016) Standard Project Title: Good Neighbor Center CITY OF TIGARD Location: Tigard, Oregon DIVISION Climate Zone: 4c Project Type: Addition Vertical Glazing/Wall Area: 3% Performance Sim. Specs: EnergyPlus 8.1.0.009 (EPW: USA_OR_Portland.Intl.AP.726980 TMY3.epw) Construction Site: Owner/Agent: Designer/Contractor: Building Area Floor Area 1-LAUNDRY ROOM (Dormitory) : Residential 140 Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factory.) Perimeter Roof:Attic Roof,Wood joists, [Bldg. Use 1-LAUNDRY ROOM] 140 49.0 0.0 0.021 0.021 Floor: Unheated Slab-On-Grade,Vertical 2 ft., [Bldg. Use 1- 53 --- 15.0 0.520 0.520 LAUNDRY ROOM] (c) NORTH Int. Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1- LAUNDRY 177 21.0 0.0 0.061 0.089 ROOM] EA T Ext.Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1- LAUNDRY 117 21.0 0.0 0.062 0.064 ROOM] Window: Vinyl Frame: Operable, Perf. Specs.: Product ID 16 --- --- 0.310 0.310 pending ID, SHGC 0.36,VT 1.00, [Bldg. Use 1- LAUNDRY ROOM](b) SOUTH Ext.Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1- LAUNDRY 177 21.0 0.0 0.062 0.064 ROOM] Door: Insulated Metal, Swinging, [Bldg. Use 1 - LAUNDRY 21 --- --- 0.680 0.370 ROOM] WEST Int. Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1-LAUNDRY 117 21.0 0.0 0.061 0.089 ROOM] (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Project Notes Project Title: Good Neighbor Center Report date: 11/20/20 Data filename: Page 1 of 8 Envelope PASSES: Design 4%better than code Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 90.1 (2016) Standard requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. CoU► "( emvo4Ielectxcr /112ZH rir T 01 - Z-8 - 2a2 Name-Title Signature Date GOOD NEIGHBOR CENTER11130 SW Greenburg Rd.Tigard, OR 97223 Project Title: Good Neighbor Center Report date: 11/20/20 Data filename: Page 2 of 8 COMcheck Software Version COMcheckWeb 1 i 1141Inspection Checklist Energy Code: 90.1 (2016) Standard Requirements: 95.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # I Plan Review Complies? Comments/Assumptions & Req.ID l 4.2.2, Plans and/or specifications provide all ❑Complies 5.4.3.1.1, information with which compliance ❑Does Not 5.7 can be determined for the building ❑Not Observable [PR1]1 envelope and document where exceptions to the standard are ❑Not Applicable claimed. Additional Comments/Assumptions: 1 High Impact(Tier 1) . 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Good Neighbor Center Report date: 11/20/20 Data filename: Page 3 of 8 Section Footing/Foundation Plans Verified Field Verified # Inspection Value Value & Req.ID Complies? Comments/Assumptions 4.2.4 Installed below-grade wall R- R- ❑Complies See the Envelope Assemblies [FO1)2 insulation type and R-value "'Does Not table for values. consistent with insulation specifications reported in plans ❑Not Observable and COMcheck reports. ❑Not Applicable 4.2.4 Installed slab-on-grade insulation R- R- ElComplies See the Envelope Assemblies (FO3)2 type and R-value consistent with ❑ Unheated ❑ Unheated ❑Does Not table for values. insulation specifications reported ❑ Heated ❑ Heated in plans and COMcheck reports. ❑Not Observable ❑Not Applicable 5.8.1.2 Slab edge insulation installed per ❑Complies Requirement will be met. [FO4]2 manufacturer's instructions. El Does Not ❑Not Observable ❑Not Applicable 5.5.3.5 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies [FO5]2 depth/length. ❑Does Not table for values. ['Not Observable ❑Not Applicable 5.8.1.7 Exterior insulation protected ❑Complies Requirement will be met. [FO6]1 against damage, sunlight, ❑Does Not moisture, wind, landscaping and equipment maintenance ❑Not Observable activities. ONot Applicable 5.8.1.7.3 Insulation in contact with the ❑Complies Requirement will be met. [FO7]1 ground has<=0.3%water ❑Does Not absorption rate per ASTM C272. ❑Not Observable ❑Not Applicable 6.4.4.1.5 Bottom surface of floor structures R- R- ❑Complies Exception: Requirement [FO11]3 incorporating radiant heating ❑Does Not does not apply. insulated to>=R-3.5. ['Not Observable See the Envelope Assemblies ENot Applicable table for values. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Good Neighbor Center Report date: 11/20/20 Data filename: Page 4 of 8 Section IPlans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 5.4.3.2 Factory built and site-assembled ❑Complies Requirement will be met. [FR1]3 fenestration and doors are ❑Does Not labeled or certified as meeting air leakage requirements. ❑Not Observable ❑Not Applicable 5.5.4.3a Vertical fenestration U-Factor. U- U- ❑Complies See the Envelope Assemblies [FR8]1 ❑Does Not table for values. ['Not Observable ❑Not Applicable 5.5.4.3b Skylight fenestration U-Factor. U- U- ❑Complies See the Envelope Assemblies [FR911 ❑Does Not table for values. ❑Not Observable ❑Not Applicable 5.5.4.4.1 Vertical fenestration SHGC value. ! SHGC: SHGC: ❑Complies See the Envelope Assemblies [FR10]1 ❑Does Not table for values. ❑Not Observable ❑Not Applicable 5.5.4.4.2 Skylight SHGC value. SHGC: SHGC: ❑Complies See the Envelope Assemblies [FRll]1 El Does Not table for values. ['Not Observable ❑Not Applicable VAN" Mggea 5.8.2.1, Fenestration products rated (U- aka ' ts,❑Complies Requirement will be met. 5.8.2.3, factor, SHGC, and VT)in " ❑Does Not 5.8.2.4, accordance with NFRC or energy 5.8.2.5 code defaults are used. ❑Not Observable [FR12]2 ❑Not Applicable 5.8.2.2 Fenestration and door products ❑Complies Requirement will be met. [FR13]1 are labeled, or a signed and ;: k *sa04/*** *, ❑Does Not dated certificate listing the U- factor, SHGC,VT, and air leakage ❑Not Observable rate has been provided by the ❑Not Applicable manufacturer. 5.5.3.6 U-factor of opaque doors U- U- ❑Complies See the Envelope Assemblies [FR14]2 associated with the building ❑ Swinging ❑ Swinging ❑Does Not table for values. thermal envelope meets ❑ Nonswinging ❑ Nonswinging ❑Not Observable requirements. ENot Applicable 5.4.3.1 Continuous air barrier is ❑Complies Requirement will be met. 444 [FR15] wrapped, sealed, caulked, ❑Does Not gasketed,and/or taped in an approved manner, except in ❑Not Observable semiheated spaces in climate ❑Not Applicable zones 1-6. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) ±3 Low Impact(Tier 3) Project Title: Good Neighbor Center Report date: 11/20/20 Data filename: Page 5 of 8 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 4.2.4 Installed roof insulation type and R- R- ❑Complies See the Envelope Assemblies [IN2]1 R-value consistent with insulation ❑ Above deck ❑ Above deck EDoes Not table for values. specifications reported in plans ❑ Metal ❑ Metal and COMcheck reports. For some :Not Observable ceiling systems, verification may ❑ Attic ❑ Attic ❑Not Applicable need to occur during Framing Inspection. 5.8.1.2, Roof insulation installed per ❑Complies Requirement will be met. 5.8.1.3 manufacturer's instructions. ❑Does Not [IN3]1 Blown or poured loose-fill insulation is installed only where Not Observable the ceiling slope is<= 3:12. ❑Not Applicable 4.2.4 Installed above-grade wall R- R- ❑Complies See the Envelope Assemblies [IN6]1 insulation type and R-value ❑ Mass IllMass ❑Does Not table for values. consistent with insulation ❑ Metal ❑ Metal specifications reported in plans ❑Not Observable ❑ and COMcheck reports. ❑ Steel Steel ❑Not Applicable ❑ Wood ❑ Wood 5.8.1.2 Above-grade wall insulation ❑Complies Requirement will be met. [IN7]1 installed per manufacturer's * i ❑Does Not instructions. , ' /*" " 'i ; x *, rrie ❑Not Observableg'f a" �a . Ata �[ ,,as% .,v , ,❑Not Applicable 4.2.4 Installed floor insulation type and R- R- ❑Complies See the Envelope Assemblies [IN8]2 R-value consistent with insulation ❑ Mass ❑ Mass ❑Does Not table for values. specifications reported in plans ❑ Steel ❑ Steel and COMcheck reports. ❑Not Observable ❑ Wood ❑ Wood ❑Not Applicable 5.8.1.1 Building envelope insulation is ❑Complies Requirement will be met. [IN10]2 labeled with R-value or insulation ❑Does Not certificate has been provided listing R-value and other relevant ; ❑Not Observable data. h" ❑Not Applicable axa *to i - 1i rt yk 5.8.1.9 Buildingenvelope insulation " 1` *' A}* ',� � �P 1.44,* : ; 4 1� ,❑❑Complies Requirement will be met. [IN18]2 extends over the full area of the #a ��',;'" � � *,g, , } , 4 ' Does Not component at the proposed rated � - f" •eke,, , 'a R or U value. Not Observable ,r ❑Not Applicable 5.8.1.4 Eaves are baffled to deflect air to e �� El Complies Requirement will be met. [IN11]2 above the insulation. �' * 0 r-° ` A '�'", ¢ ❑Does Not 1"° €�`❑Not Observable ❑Not Applicable 5.8.1.5 Insulation is installed in > � l 7� �❑ r � r - �"a Complies Requirement will be met. [IN12]2 substantial contact with the %�I❑Does Not inside surface separating conditioned space from ,,a :❑Not Observable unconditional space. °5 � CI Not Applicable 5.8.1.6 Recessed equipment installed in ❑Complies Requirement will be met. [IN13]2 building envelope assemblies ,, �a.,a,• + . ,�.: 1 _ ❑Does Not does not compress the adjacent a insulation. ?' ❑Not Observable ❑Not Applicable 5.8.1.7.1 Attics and mechanical rooms '' ❑Complies Requirement will be met. [IN15]2 have insulation protected where ❑Does Not adjacent to attic or equipment access. ['Not Observable �` ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Good Neighbor Center Report date: 11/20/20 Data filename: Page 6 of 8 W _ • Section 1 Plans Verified Field Verified 1 # i Insulation Inspection i Complies? Comments/Assumptions Value Value & Req.ID j 5.8.1.7.2 Foundation vents do not interfere ❑Complies Requirement will be met. [IN10 with insulation. ❑Does Not ❑Not Observable ❑Not Applicable .................. ..............LilNot ded to meet the ❑Complies Requirement will be met. equirements ❑Does Not lled on top of a suspended ceiling. Mark this ❑Not Observable requirement compliant if ❑Not Applicable insulation is installed accordingly. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Good Neighbor Center Report date: 11/20/20 Data filename: Page 7 of 8 Section • Final Inspection Complies? ` Comments/Assumptions & Req.ID 5.4.3.3 Weatherseals installed on all loading ❑Complies Exception: Requirement does not apply. [F11]1 dock cargo doors in Climate Zones 4- ❑Does Not 8. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Good Neighbor Center Report date: 11/20/20 Data filename: Page 8 of 8