Report 909_20ZI-O0C510
i//30 cam« i 5c
COMcheck Software Version COMcheckWeb
inflr
‘ifi Envelope Compliance Certificate
RECEWED
Project Information lAN 2 8 202
Energy Code: 90.1 (2016) Standard
Project Title: Good Neighbor Center CITY OF TIGARD
Location: Tigard, Oregon DIVISION
Climate Zone: 4c
Project Type: Addition
Vertical Glazing/Wall Area: 3%
Performance Sim. Specs: EnergyPlus 8.1.0.009 (EPW: USA_OR_Portland.Intl.AP.726980 TMY3.epw)
Construction Site: Owner/Agent: Designer/Contractor:
Building Area Floor Area
1-LAUNDRY ROOM (Dormitory) : Residential 140
Envelope Assemblies
Assembly Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factory.)
Perimeter
Roof:Attic Roof,Wood joists, [Bldg. Use 1-LAUNDRY ROOM] 140 49.0 0.0 0.021 0.021
Floor: Unheated Slab-On-Grade,Vertical 2 ft., [Bldg. Use 1- 53 --- 15.0 0.520 0.520
LAUNDRY ROOM] (c)
NORTH
Int. Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1- LAUNDRY 177 21.0 0.0 0.061 0.089
ROOM]
EA T
Ext.Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1- LAUNDRY 117 21.0 0.0 0.062 0.064
ROOM]
Window: Vinyl Frame: Operable, Perf. Specs.: Product ID 16 --- --- 0.310 0.310
pending ID, SHGC 0.36,VT 1.00, [Bldg. Use 1- LAUNDRY
ROOM](b)
SOUTH
Ext.Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1- LAUNDRY 177 21.0 0.0 0.062 0.064
ROOM]
Door: Insulated Metal, Swinging, [Bldg. Use 1 - LAUNDRY 21 --- --- 0.680 0.370
ROOM]
WEST
Int. Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1-LAUNDRY 117 21.0 0.0 0.061 0.089
ROOM]
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
(c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors.
Project Notes
Project Title: Good Neighbor Center Report date: 11/20/20
Data filename: Page 1 of 8
Envelope PASSES: Design 4%better than code
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application.The proposed envelope systems have been
designed to meet the 90.1 (2016) Standard requirements in COMcheck Version COMcheckWeb and to comply with any applicable
mandatory requirements listed in the Inspection Checklist.
CoU► "( emvo4Ielectxcr /112ZH rir T 01 - Z-8 - 2a2
Name-Title Signature Date
GOOD NEIGHBOR CENTER11130 SW Greenburg Rd.Tigard, OR 97223
Project Title: Good Neighbor Center Report date: 11/20/20
Data filename: Page 2 of 8
COMcheck Software Version COMcheckWeb
1 i 1141Inspection Checklist
Energy Code: 90.1 (2016) Standard
Requirements: 95.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# I Plan Review Complies? Comments/Assumptions
& Req.ID l
4.2.2, Plans and/or specifications provide all ❑Complies
5.4.3.1.1, information with which compliance ❑Does Not
5.7 can be determined for the building ❑Not Observable
[PR1]1 envelope and document where
exceptions to the standard are ❑Not Applicable
claimed.
Additional Comments/Assumptions:
1 High Impact(Tier 1) . 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Good Neighbor Center Report date: 11/20/20
Data filename: Page 3 of 8
Section Footing/Foundation Plans Verified Field Verified
# Inspection Value Value
& Req.ID Complies? Comments/Assumptions
4.2.4 Installed below-grade wall R- R- ❑Complies See the Envelope Assemblies
[FO1)2 insulation type and R-value "'Does Not table for values.
consistent with insulation
specifications reported in plans ❑Not Observable
and COMcheck reports. ❑Not Applicable
4.2.4 Installed slab-on-grade insulation R- R- ElComplies See the Envelope Assemblies
(FO3)2 type and R-value consistent with ❑ Unheated ❑ Unheated ❑Does Not table for values.
insulation specifications reported ❑ Heated ❑ Heated
in plans and COMcheck reports. ❑Not Observable
❑Not Applicable
5.8.1.2 Slab edge insulation installed per ❑Complies Requirement will be met.
[FO4]2 manufacturer's instructions. El Does Not
❑Not Observable
❑Not Applicable
5.5.3.5 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies
[FO5]2 depth/length. ❑Does Not table for values.
['Not Observable
❑Not Applicable
5.8.1.7 Exterior insulation protected ❑Complies Requirement will be met.
[FO6]1 against damage, sunlight, ❑Does Not
moisture, wind, landscaping and
equipment maintenance ❑Not Observable
activities. ONot Applicable
5.8.1.7.3 Insulation in contact with the ❑Complies Requirement will be met.
[FO7]1 ground has<=0.3%water ❑Does Not
absorption rate per ASTM C272.
❑Not Observable
❑Not Applicable
6.4.4.1.5 Bottom surface of floor structures R- R- ❑Complies Exception: Requirement
[FO11]3 incorporating radiant heating ❑Does Not does not apply.
insulated to>=R-3.5. ['Not Observable
See the Envelope Assemblies
ENot Applicable table for values.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Good Neighbor Center Report date: 11/20/20
Data filename: Page 4 of 8
Section IPlans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
5.4.3.2 Factory built and site-assembled ❑Complies Requirement will be met.
[FR1]3 fenestration and doors are ❑Does Not
labeled or certified as meeting air
leakage requirements. ❑Not Observable
❑Not Applicable
5.5.4.3a Vertical fenestration U-Factor. U- U- ❑Complies See the Envelope Assemblies
[FR8]1 ❑Does Not table for values.
['Not Observable
❑Not Applicable
5.5.4.3b Skylight fenestration U-Factor. U- U- ❑Complies See the Envelope Assemblies
[FR911 ❑Does Not table for values.
❑Not Observable
❑Not Applicable
5.5.4.4.1 Vertical fenestration SHGC value. ! SHGC: SHGC: ❑Complies See the Envelope Assemblies
[FR10]1 ❑Does Not table for values.
❑Not Observable
❑Not Applicable
5.5.4.4.2 Skylight SHGC value. SHGC: SHGC: ❑Complies See the Envelope Assemblies
[FRll]1 El Does Not table for values.
['Not Observable
❑Not Applicable
VAN" Mggea
5.8.2.1, Fenestration products rated (U- aka ' ts,❑Complies Requirement will be met.
5.8.2.3, factor, SHGC, and VT)in " ❑Does Not
5.8.2.4, accordance with NFRC or energy
5.8.2.5 code defaults are used. ❑Not Observable
[FR12]2 ❑Not Applicable
5.8.2.2 Fenestration and door products ❑Complies Requirement will be met.
[FR13]1 are labeled, or a signed and ;: k *sa04/*** *, ❑Does Not
dated certificate listing the U-
factor, SHGC,VT, and air leakage ❑Not Observable
rate has been provided by the ❑Not Applicable
manufacturer.
5.5.3.6 U-factor of opaque doors U- U- ❑Complies See the Envelope Assemblies
[FR14]2 associated with the building ❑ Swinging ❑ Swinging ❑Does Not table for values.
thermal envelope meets ❑ Nonswinging ❑ Nonswinging ❑Not Observable
requirements.
ENot Applicable
5.4.3.1 Continuous air barrier is ❑Complies Requirement will be met.
444
[FR15] wrapped, sealed, caulked, ❑Does Not
gasketed,and/or taped in an
approved manner, except in ❑Not Observable
semiheated spaces in climate ❑Not Applicable
zones 1-6.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) ±3 Low Impact(Tier 3)
Project Title: Good Neighbor Center Report date: 11/20/20
Data filename: Page 5 of 8
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
4.2.4 Installed roof insulation type and R- R- ❑Complies See the Envelope Assemblies
[IN2]1 R-value consistent with insulation ❑ Above deck ❑ Above deck EDoes Not table for values.
specifications reported in plans ❑ Metal ❑ Metal
and COMcheck reports. For some :Not Observable
ceiling systems, verification may ❑ Attic ❑ Attic ❑Not Applicable
need to occur during Framing
Inspection.
5.8.1.2, Roof insulation installed per ❑Complies Requirement will be met.
5.8.1.3 manufacturer's instructions. ❑Does Not
[IN3]1 Blown or poured loose-fill
insulation is installed only where Not Observable
the ceiling slope is<= 3:12. ❑Not Applicable
4.2.4 Installed above-grade wall R- R- ❑Complies See the Envelope Assemblies
[IN6]1 insulation type and R-value ❑ Mass IllMass ❑Does Not table for values.
consistent with insulation ❑ Metal ❑ Metal
specifications reported in plans ❑Not Observable
❑
and COMcheck reports. ❑ Steel Steel ❑Not Applicable
❑ Wood ❑ Wood
5.8.1.2 Above-grade wall insulation ❑Complies Requirement will be met.
[IN7]1 installed per manufacturer's * i ❑Does Not
instructions. , ' /*" "
'i ; x *, rrie ❑Not Observableg'f
a"
�a . Ata �[ ,,as% .,v , ,❑Not Applicable
4.2.4 Installed floor insulation type and R- R- ❑Complies See the Envelope Assemblies
[IN8]2 R-value consistent with insulation ❑ Mass ❑ Mass ❑Does Not table for values.
specifications reported in plans ❑ Steel ❑ Steel
and COMcheck reports. ❑Not Observable
❑ Wood ❑ Wood ❑Not Applicable
5.8.1.1 Building envelope insulation is ❑Complies Requirement will be met.
[IN10]2 labeled with R-value or insulation ❑Does Not
certificate has been provided
listing R-value and other relevant ; ❑Not Observable
data. h" ❑Not Applicable
axa *to i - 1i rt yk
5.8.1.9 Buildingenvelope insulation " 1` *' A}* ',� � �P 1.44,* : ; 4 1� ,❑❑Complies Requirement will be met.
[IN18]2 extends over the full area of the #a ��',;'" � � *,g, , } , 4 '
Does Not
component at the proposed rated � - f" •eke,, ,
'a
R or U value. Not Observable
,r ❑Not Applicable
5.8.1.4 Eaves are baffled to deflect air to e �� El Complies Requirement will be met.
[IN11]2 above the insulation. �' * 0 r-° ` A '�'", ¢ ❑Does Not
1"° €�`❑Not Observable
❑Not Applicable
5.8.1.5 Insulation is installed in > � l 7� �❑
r � r - �"a Complies Requirement will be met.
[IN12]2 substantial contact with the %�I❑Does Not
inside surface separating
conditioned space from ,,a :❑Not Observable
unconditional space. °5 � CI Not Applicable
5.8.1.6 Recessed equipment installed in ❑Complies Requirement will be met.
[IN13]2 building envelope assemblies ,, �a.,a,• + . ,�.: 1 _ ❑Does Not
does not compress the adjacent a
insulation. ?' ❑Not Observable
❑Not Applicable
5.8.1.7.1 Attics and mechanical rooms '' ❑Complies Requirement will be met.
[IN15]2 have insulation protected where ❑Does Not
adjacent to attic or equipment
access. ['Not Observable
�` ❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Good Neighbor Center Report date: 11/20/20
Data filename: Page 6 of 8
W _
• Section 1 Plans Verified Field Verified 1
# i Insulation Inspection i Complies? Comments/Assumptions
Value Value
& Req.ID j
5.8.1.7.2 Foundation vents do not interfere ❑Complies Requirement will be met.
[IN10 with insulation. ❑Does Not
❑Not Observable
❑Not Applicable
.................. ..............LilNot
ded to meet the ❑Complies Requirement will be met.
equirements ❑Does Not
lled on top of a
suspended ceiling. Mark this ❑Not Observable
requirement compliant if ❑Not Applicable
insulation is installed accordingly.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Good Neighbor Center Report date: 11/20/20
Data filename: Page 7 of 8
Section •
Final Inspection Complies? ` Comments/Assumptions
& Req.ID
5.4.3.3 Weatherseals installed on all loading ❑Complies Exception: Requirement does not apply.
[F11]1 dock cargo doors in Climate Zones 4- ❑Does Not
8.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Good Neighbor Center Report date: 11/20/20
Data filename: Page 8 of 8