Loading...
Report NEG2021-aNs2 ^ `" FV-1115VK2 WiCC r' A/ iJ/r n r Built-In sell Adjusting AiMow Capability VENTILATION':FAN Specification Submittal Data/ Panasonic Ventilation Fan Description Customizable ceiling mount ventilating fan,low sone and rated for continuous operation. 611 ductENERGY STAR®rated and certified by the Home Ventilating Institute(HVI).Evaluated by the Underwriters Laboratories and conforms to both UL and cUL standards. Motor/Blower: r •Enclosed brushless ECM smart motor technology rated for continuolR on E I V D ,� •Adjustable ventilation rates at 110-130-150 CFM 1 1 L•• \Il/i� `A 1 / l `•Power rating of 120 volts and 60 Hz �V o •UL and cUL listed for tub/shower enclosure when GFCI protected MAR 2 20Z1 lam " 11 •Motor equipped with thermal cutoff fuse r� , raga^'r IU`t' •Removable permanentlylubricated plug-in motoryl �� I�� � • p g CITY OF TIGARDSION %i i'` --" ,r •Housing: aa( Q l 'I•Environmentally friendly 26 gauge housing using Zinc-Aluminum-Magri FfIM fit{ i a, � •Integrated 6"diameter duct adapter •Built-in damper reduces back draft and helps with blower door testing va^ to va'•� •Built-in metal flange provides blocking for penetrations through drywall as an Air - Barrier,and assists with the decrease in leakage in the Building Envelope during blower door testing •Suitable for installation in ceilings insulated up to R60 to / ,. •Articulating and expandable installation bracket up to 24" Grille: �•�� \ _.__� �� \" > � ' •Attractive design using Poly Pro material •Attaches directly to housing with torsion springs to^ ta^" •Includes a motion sensor cap for use as a cover when the motion sensor -�� �� Performance Curve 6"duct °'°'� Plug'n Play'M module has not been selected Warranty: •ECM Motor;6 Years from original purchase date •ALL Parts:3 Years from original purchase date FV-1115VK2 Architectural Specifications: Customizable ceiling mount ventilation fan, ENERGY STAR® rated with built-in speed selector.Select from 110/130/150 CFM with<0.3 sone as certified by the Home Ventilating Institute(HVI)at 0.1 w.g.with 112/130/151 CFM and no more than 0.3/0.4/0.7 sones at 0.25 w.g.and 105/124/132 CFM at 0.375 w.g.Power Consumption shall be no greater than 6.9/9.2/12.9 watts at 0.1 w.g.and 12.8/16.5/22.0 watts at 0.25 w.g.and 17.9/22.1/24.4 watts at 0.375 w.g.ENERGY STAR®rated with efficiency of no less than 16.0/14.2/11.7 CFM/watt at 0.1 w.g.and 8.7/7.9/6.8 CFM/watt at 0.25 w.g.and 5.8/5.6/5.4 CFM/watt at 0.375 w.g.The motor shall be enclosed with brushless ECM motor engineered to run continuously. ECM motor speed shall automatically increase when the fan senses static \, _ pressure to maintain selected CFM.Power rating shall be 120v/60Hz.Duct diameter shall s am _ —,nc." be no Must Speed Plug'N Play"'modules provide up to three additional features.Select •. =r" with Time Delay,Condensation Sensor,and SmartAction Motion Sensor. £°.• --i Fan shall be RoHS Compliant and UL and cUL listed for tub/shower enclosure when GFCI ^ t,i protected.Also suitable for installation in ceilings insulated up to R60.. Fan can be used A°'° i .•r" to comply with ASHRAE 62.2, LEED,ENERGY STAR®IAP,EarthCraft,California Title-24 °° I tl — e'wa; and WA Ventilation Code. • i trt / -"`°"°'" r ... m° o,°4l i ` —°• n mn •gT F�o� ECM Motor Technology: .T . f ECM When fan senses static pressure,its speed is automatically increased to ° • '°° do; r ct.' ensure that the desired CFM is not compromised,which allows the fan to °°° °""""`"t �CNNeo.P perform as rated. 'NAM,eseern indicates star r100anra in rota Insaretcos",noes gun o.'tll•bo375' Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: For complete Installation Instructions visit us.panasonic.com/ventfans Ceding Radiation Damper.WhisperGreen Select"a IX Bated for use vAth the Panasonic Ceiling Radiation Damper(Model#.PC-RD05C5,sold seperateyf, 1 c) Wh er±.,r e(eGt- as„-S Ad;usting FV-1115VK2 ' -' ��' Airflow Capablllty VENTILATION .FAN Plug 'N PlayTM Modules Plug 'N Play'"modules provide up to three additional features.Select from Multi-Speed with Time Delay,Motion Sensor,and Condensation Sensor. FV-VS15VK1: Multi-Speed with Time Delay Allows you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous ventilation requirements. The fan runs continuously at a pre-set lower level (0,50-120 CFM,in 10 CFM increments),then elevates to a maximum level of operation (110-130-150 CFM) when the wall switch is turned on, or when the motion sensor or Condensation Sensor module is activated.A High/Low delay timer returns the fan to the pre-set CFM level after a period of time set by the user. '` ,> FV-MSVK1: Motion Sensor .t 01 --r 4.fir =`. Automatically activates when someone enters the room.Once the settings have been applied,the fan becomes truly automatic. This module also activates a 20 minute delay off timer for the fan. FV-CSVK1: Condensation Sensor Helps control bathroom condensation to prevent mold and mildew.Sensor technology detects relative humidity and temperature to to anticipate dew point,automatically turning the fan on to control humidity.Built-in Relative Humidity(RH)sensitivity adjustment enables fine tuning for moist conditions and for satisfying CalGreen requirements.When the condensation sensor is used in conjunction with multi-speed functionality,the fan will kick up to high speed when the condensation sensor detects moisture in the room.This module also activates a 20 minute delay off timer for the fan. Fan Specifications WhisperGreen Select F -1115VK2 Static Pressure in inches w.g. 0.1 0.25 0.375 0.1 0,25 0.375 0.1 0.25 0,375 Air Volume(CFM) 150 151 132 130 130 124 110 112 105 Noise(sones) <0.3 0.7 - <0.3 0.4 - <0.3 0.3 - Power Consumption(watts) 12.9 22.0 24.4 9.2 16.5 22.1 6.9 12.8 17.9 Energy Efficiency(CFM/Watt) 11.7 6.8 5.4 14.2 7.9 56 16.0 8.7 5.8 Speed(RPM) 684 916 1084 645 900 1080 625 894 1083 Current(amps) 0.14 0.22 0.24 0.10 0.17 0,22 0.08 0.13 0.18 MAX.Current(amps) 0.24 Power Rating(V/Hz) 120/50 ENERGY STAR rated Yes "Industry research indicates static pressure in typical installations ranges from 0.20"to 0.375' Fan Specifications FV- 115VK2+FV•VS15VKi Multi Spee• Plug'N Play-module) Static Pressure in inches w.g. 0.1 0.25 1.3/C 0.1 0.25 1.37- 0.1 0.25 0.37' 0.1 0.25 t.37. 0.1 0.25 0,375 0.1 0.25 0.37 0.1 0.25 1.375 0.1 0.25 3.37. 0.1 0.25 1 3A. 0.1 0.25 1.37. Air Volume(GPM) 150 151 132 130 130 124 120 120 122 110 112 105 100 100 97 90 91 90 80 81 80 70 71 70 60 60 60 50 50 50 Noise(sons) <0.3 0.7 - <0.3 0.4 - <0.3 0.3 - <0.3 0.3 - <0.3 0.2 - <0.3 0.3 - <0.3 0.3 - <0.3 0.4 - <0.3 0.4 - <0.3 0.5 - Power Consumption(watts) 12.9 22.0 24.4 9.2 16.5 22.1 7.7 14.0 20.5 6.9 12.8 17.9 5.5 11.0 16.0 4.7 9.7 15.0 4.2 9.0 13.9 3.7 8.1 12.2 3.3 7.2 11.2 3.0 6.4 10.2 Energy Efficiency(CFMANatt) 11.7 6.8 5.4 14.2 7.9 5.6 15.7 8.6 6.0 16.0 8.7 5.8 18.2 9.1 6.0 19.1 9.3 6.0 19.0 9.0 5.7 19.2 8.8 5.8 18.2 8.3 5.3 17.3 8.1 5.1 Speed(RPM) 684 916 1084 645 900 1080 633 895 1086 625 894 1083 615 898 10' '602 900 1099 608 912 110, 591 914 1109 608 913 1117 609 910 1116 Current(amps) 0.140.220.240.100.170.220.090.150.210.080,130.180.070.120.160.060.100.150.050.100.140.050.090.130.040.080.120.040.070.11 MAX.Current(amps) 0.33 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes 'Industry research indicates static pressure in typical installations ranges from 0.20'to 0.375' Panasonic Life Solutions Company of America r',Most Efficient IAD Division 2020 Two Riverfront Plaza Newark,NJ 07102 ®w�"i<,,,.i, us.pa nasoni c.com/ve ntfans HVI rpTr1E0 �� as Panasonic IAQ19073SS r3 t c>xssom�o ®k `., • "�^°°°° FV-1115VK2 Vey h!r r e r `QCQLt• Built-In Self Adjusting VENTILATION Q FAN �f Airflow Capability Specification Submittal Data /Panasonic Ventilation Fan Description Customizable ceiling mount ventilating fan,low sone and rated for continuous operation. ENERGY STAR'rated and certified by the Home Ventilating Institute(HVI).Evaluated by 6" duct the Underwriters Laboratories and conforms to both UL and cUL standards. Motor/Blower: 10. •Enclosed brushless ECM smart motor technology rated for continuous op I rr r T •Adjustable ventilation rates at 110-130-150 CFM E iV`® I I , •Power rating of 120 volts and 60 Hz i^�' \� 5" •UL and cUL listed for tub/shower enclosure when GFCI protected � - s`! •Motor equipped with thermal cutoff fuse MAR 2 2021 l eQ PP per- . •Removable permanently lubricated plug-in motor Tare" tl nl�q 'I�I�l�l � ;;ITY OF TIGARD liVii , Housing: i •Environmentally friendly 26 gauge housing using Zinc-Aluminum-Magnesium, ) G DIVISION '�!/ „r •Integrated 6"diameter duct adapter ���I \: . •Built-in damper reduces back draft and helps with blower door testing � -101/4" 101/4" •Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier,and assists with the decrease in leakage in the Building Envelope during blower door testing •Suitable for installation in ceilings insulated up to R60 •Articulating and expandable installation bracket up to 24" �� Grille: // ••. -- •Attractive design using Poly Pro material \\\\ •Attaches directly to housing with torsion springs 13" 13" •Includes a motion sensor cap for use as a cover when the motion sensor Plug'n PlayT",module has not been selected Warranty: •ECM Motor:6 Years from original purchase date •ALL Parts:3 Years from original purchase date FV-1115VK2 Architectural Specifications: Customizable ceiling mount ventilation fan, ENERGY STAR® rated with built-in speed selector.Select from 110/130/150 CFM with<0.3 sone as certified by the Home Ventilating Institute(HVI)at 0.1 w.g.with 112/130/151 CFM and no more than 0.3/0.4/0.7 sones at 0.25 w.g.and 105/124/132 CFM at 0.375 w.g.Power Consumption shall be no greater than Performance Curve 6"duct 6.9/9.2/12.9 watts at 0.1 w.g.and 12.8/16.5/22.0 watts at 0.25 w.g.and 17.9/22.1/24.4 watts at 0.375 w.g.ENERGY STAR®rated with efficiency of no less than 16.0/14.2/11.7 CFM/watt at 0.1 w.g.and 8.7/7.9/6.8 CFM/watt at 0.25 w.g.and 5.8/5.6/5.4 CFM/watt 0.70 at 0.375 w.g.The motor shall be enclosed with brushless ECM motor engineered to run continuously. ECM motor speed shall automatically increase when the fan senses static '`" _-;,",„ pressure to maintain selected CFM.Power rating shall be 120v/60Hz.Duct diameter shall ;•,o .. ,a be no less than 6".Plug'N Play"'modules provide up to three additional features.Select —'A�•" from Multi-Speed with Time Delay,Condensation Sensor,and SmartAction Motion Sensor. yew Fan shall be RoHS Compliant and UL and cUL listed for tub/shower enclosure when GFCI F I j ! 'I __w w protected.Also suitable for installation in ceilings insulated up to R60..Fan can be used :°'° _RCN to comply with ASHRAE 62.2,LEED,ENERGY STAFF IAP,EarthCraft,California Title-24 I , •:° and WA Ventilation Code, I i / i —.-.,... OCT F<o ECM Motor Technology: 1 • ', When fan senses static pressure, its speed is automatically increased to o m,aa , ,...0i,, 4. ensure that the desired CFM is not compromised,which allows the fan to arli.I""' >oo CNNO.9 perform as rated. 'Musty rescorct indicates a•uco,®„ah ti,k4 lnaalzk„s,an550170rnOMo'mans• Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: For complete Installation Instructions visit us.panasonic.com/ventfans Ceiling Radiation Camper'.NlhaperGreen Select-is UL listed for use with the Panasonic Ceiling Radiation Camper(Model a'PC-RWSC5,sod separately). . - 4T e hiy�/� " FV-1115VK2 sper sQCeG Built-In SelfActustung s ON �r Airflow Capability VENTILATION FAN Plug 'N PlayTM Modules Plug 'N Play-modules provide up to three additional features.Select from Multi-Speed with Time Delay,Motion Sensor,and Condensation Sensor. FV-VS15VK1: Multi-Speed with Time Delay . Allows you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous ventilation requirements. The fan runs continuously at a pre-set lower level (0,50-120 CFM,in 10 CFM increments),then elevates to a maximum level of operation (110-130-150 CFM) when the wall switch is turned on, or when the motion sensor or Condensation Sensor module is activated.A High/Low delay timer returns the fan to the pre-set CFM level after a period of time set by the user. FV-MSVK1: Motion Sensor 2 � Automaticalyactivateswhensomeoneenterstheroom.Oncethesettingshavebeenapplied,thefanbecomestrulyautomatic. This module also activates a 20 minute delay off timer for the fan. FV-CSVK1: Condensation Sensor Helps control bathroom condensation to prevent mold and mildew.Sensor technology detects relative humidity and temperature 4a to anticipate dew point,automatically turning the fan onto control humidity.Built-in Relative Humidity(RH)sensitivity adjustment enables fne tuning for moist conditions and for satisfying CalGreen requirements.When the condensation sensor is used in conjunction with multi-speed functionality,the fan will kick up to high speed when the condensation sensor detects moisture in the room.This module also activates a 20 minute delay off timer for the fan, Fan Specifications WhisperGreen Select":FV-1115VK2 Static Pressure in inches w.g. 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 0.375 Air Volume(CFM) 150 151 132 130 130 124 110 112 105 Noise(sones) <0.3 0.7 - <0.3 0.4 - <0.3 0.3 - Power Consumption(watts) 12.9 22.0 24.4 9.2 16.5 22.1 6,9 12.8 17.9 Energy Efficiency(CFM/Watt) 11.7 6.8 5.4 14.2 7.9 5.6 16.0 8.7 5.8 Speed(RPM) 684 916 1084 645 900 1080 625 694 1083 Current(amps) 0.14 0.22 0.24 0.10 0.17 0,22 0.08 0.13 0.18 MAX.Current(amps) 0.24 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes 'Industry research indicates static pressure in typical installations ranges from 0.20'to 0.375" Fan Specifications FV- 115VK2+FV-VS15VK1 ulti Speed Plug'N PI- '"module) Static Pressure in inches w.g. 0.1 0.25 0.37' 0.1 0.25 1.375 0.1 0.25 0.315 0.1 0.25 -'.37E 0.1 0.25 0.375 0.1 0.25 1.3775 0.1 0.25 4.375 0.1 0.25 3.37- 0.1 0.25 0,37r 0.1 0.25(1.37' Air Volume(cFM) 150 151 132 130 130 124 120 120 122 110 112 105 100 100 97 90 91 90 80 81 80 70 71 70 60 60 60 50 50 50 Noise(sones) <0.3 0.7 - <0.3 0.4 - <0.3 0.3 - <0.3 0.3 - <0.3 0.2 - <0.3 0.3 - <0.3 0.3 - <0.3 0.4 - <0.3 0.4 - <0.3 0.5 - Power Consumption(watts) 12.9 22.0 24.4 9.2 16.5 22.1 7.7 14.0 20.5 6.9 12.8 17.9 5.5 11.0 16.0 4.7 9.7 15.0_4.2 9.0 13.9 3.7 8.1 12.2 3.3 7.2 11.2 3.0 6.4 10.2 Energy Efficiency(CFM/Watt) 11.7 6.8 5.4 14.2 7.9 5.6 15.7 8.6 6.0 16.0 8.7 5.8 18.2 9.1 6.0 19.1 9.3 6.0 19.0 9.0 5.7 19.2 8.8 5.8 18.2 8.3 5.3 1/.3 8.1 5.1 Speed(RPM) 684 916 1084 645 900 1080 633 895 1086 625 894 1083 615 898 109'602 900 1099 608 912 110' 591 914 1109 608 913 1117 609 910 1116 Current(amps) 0.14 0.22 0.24 0.10 0.17 0.22 0.09 0.15 0.21 0.08-0.13 0.18 0.07 0.12 0.16 0.06 0.10 0.15 0.05 0.10 0.14 0.05 0.09 0.13 0.04 0.08 0.12 0.04 0.07 0.11 MAX.Current(amps) 0.33 Power Rating(V/Hz) 120/6a ENERGY STAR rated Yes 'Industry research indicates static pressure in typical installations ranges from 0.20"to 0.375' Panasonic Life Solutions Company of America Most Efficient IAQ Division . . 2Uca Two Riverfront Plaza Newark,NJ 07102 ®" wwwem99,W9°" us.panasonic.com/ventfans Ous Panasonic IAQ19073SS r3