Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY OF TIGARD MASTER PERMIT ' 0 -n COMMUNITY DEVELOPMENT Permit A: MST2021-00044 T[GAR P 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 03/23/2021 Parcel: 2S111 BD01514 Jurisdiction: Tigard Site address: 14950 SW 100TH AVE Subdivision: ALDERBROOK FARM Lot: 6 Project: Keast Project Description: 13kW rooftop solar BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $36,100.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: o Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning; N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<10oK: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0 Ea addl 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O SvcFdr: 0 Mfd Home/Feeder/Svc: 0 401-800 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener. N All Other: Y Other Description: Roof Top Solar PV System 13 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: KEAST,RICHARD&ERIN PREMIER SOLAR NW Required Items and Reports(Conditions) 14950 SW 100TH AVE 12399 NW WAKER DR TIGARD,OR 97224 PORTLAND,OR 97229 PHONE: PHONE: 503-799-9042 FAX: Total Fees: 5478.97 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: HotlY Vt17PrWPcje Permittee Signature: 0wApplicatton Call 503.639.4175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. c I Building Permit Application -F-1Z1ii a RECEIVED Residential FOR OFFICE USE ONLY Received ` , 71-. (1r�-t City of Tigard FEB 1 1 2021 DateBy: L 1�Zt J Permit No.:MST GAx I 'Lw) )49 • 13125 SW Hall Blvd.,Tigard,OR 97223 Plea Review2�n Z 2 / Other Permit: ■ Phone: 503.718.2439 Fax: 503.598.1960CITY OF TIGARD DateBy: {,� Inspection Line: 503.639.4175 Date Ready/By: /� tuns: WI See Page 2 for TlG`1RD Internet: www.tigard-or.gov BUILDING DIVISION' otified/M '1 /)� 'j' Supplemental Information r TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement El Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $ 36,100 ® 1-and 2-family dwelling El Commercial/industrial 0 Accessory building El Multi-familyNumber of bedrooms: oii ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 14950 SW 100th Ave New dwelling area: square feet City/State/ZIP: Tigard,OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Keast Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Adding 13 kW Roof Top Solar PV System Valuation: $ Existing building area: square feet New building area: square feet 0 PROPERTY OWNER 0 TENANT Number of stories: Name: Richard and Erin Keast Type of construction: Address: 14950 SW 100th Ave. Occupancy groups: City/State/ZIP: Tigard,OR 97224 Existing: Phone:(503 )504-4087 Fax:( ) New: ® APPLICANT El CONTACT PERSON BUILDING PERMIT FEES* Business name: Premier Solar NW (Please refer mjee schedule) Structural plan review fee(or deposit): Contact name: Robert M. Rathbone Address: 12399 NW Waker Dr. FLS plan review fee(if applicable): Total fees due upon application: City/State/ZIP: Portland,OR 97229 Phone:( 503 ) 828-9500 Fax::( ) Amount received: E-mail: rrathbone @premiersolarnw PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name: Prmier SolarNW Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 12399 NW Waker Dr. Solar Installation Specialty Code checklist. City/State/ZIP: Portland, OR 97229 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( 503 )828-9500 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:218826 Total fee due upon application: $201.60 Authorized signature: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: Date: 2/9/21 *Fee methodology set by Tri-County Building Industry Service Board. I:1Building\Permits\BUP-RESPermitA p.doc 02/24/2011 440-4613T(11/02/COM/WEB) , Building Permit Application Checklist 'One- and Two-Family Dwelling colt OFFICE USE ONLY Received �u City of Tigard 2I�e,2,\ \ PermitNo.:(II��u �— —11Z ■ 13125 SW Hall Blvd.,Tigard,OR 97223 Date/Bat = Phone: 503.718.2439 Fax: 503.598.1960 Associated permits: 24-Hour Inspection Line: 503.639.4175 0 Electrical ❑ Plumbing ❑ Mechanical TICiA Rp Internet: www.tigard-or.gov ElOther: THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No N/A 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ 0 ❑ 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. ❑ ❑ ❑ 3 Verification of approved plat/lot. ❑ LI ❑ 4 Fire district approval required. Name of district: . ❑ ❑ ❑ 5 Septic system permit or authorization for remodel. Existing system capacity . ❑ 0 0 6 Sewer permit. 0 0 0 7 Water district approval. 0 0 0 8 Soils report. Must carry original applicable stamp and signature on file or with application. 0 0 ❑ 9 Erosion control ❑plan 0 permit required. Include drainage-way protection,silt fence design and location of catch- ❑ ❑ 0 basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state © ❑ 0 building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if x❑ ❑ 0 there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator,lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ ❑ ❑ and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑ 0 ❑ furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ ❑ 0 floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ 0 0 Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- ❑ 0 ❑ prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing 0 0 ❑ locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered 0 0 0 systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists 0 ❑ ❑ over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. 0 0 0 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required 0 0 0 for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or 0 0 0 architect licensed in Ore•on and shall be shown to be a g.licable to the •ro'ect under review. JURISDICTIONAL SPECIFICS 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". 0 0 0 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. 0 0 0 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. 0 0 0 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. ❑ 0 0 27 "Drawn to scale"indicates standard architect or engineer scale. 0 0 0 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ 0 0 Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, 0 ❑ ❑ and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, 0 ❑ 0 including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. I:\Building\Permits\BUP-RESPemiltApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) .t Electrical Permit Application FOR OFFICE USE ONLY pal "i'_ 'vL�... 1_,,, Received \ •�� `t,' Permit#:M�?QZi (�O L{� City of TigardF, I V it Da a By: Z 1 C``r • 13125 SW Hall Blvd.,Tigard,OR 9223'"'" Plan Review _ Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Related Permit#: Inspection Line: 503.639.4175 rEB 1 1 2021 Ready Date/By: Iurs: ® See Page 2 for T I G A R D Internet: www.tigard-or.gov Notified/Method: Supplemental Information TYPE OF WO1 1' °t TIGA+RLi PLAN REVIEW ❑New construction x❑Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): ❑Service or feeder 400 amps or more 0 Building over three stories. O Demolition E Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. ❑ 1-and 2-family dwelling 0 Commercial/industrial ❑ Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural amps for all other installations. buildings. ❑Multi-family ❑Master builder ❑Other: ❑Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived 0 Addition of new motor load of system. Job#: Job site address: 14950 SW 100th Ave 100HP or more. ❑`A",'E","1-z","1-3", Tigard,OR.97224 0 Six or more residential units, occupancy. City/State/ZIP: g0 Recreational vehicle parks. 0 Health-care facilities. Suite/bld /a t.#: Project name: Keast 0 Hazardous locations. 0 Supply voltage for more than g• Fl J 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Description I Qty. I Each I Total I * New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'l 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential 75.00 2 Adding 13 kW Roof Top Solar PV System (with above sq.ft.) Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy ❑ See Page 2 IIJ PROPERTY OWNER ❑ TENANT Services or feeders installation,alteration,and/or relocation Name: Richard and Erin Keast 200 amps or less 1 100.70 100.7 2 Address: 14950 SW 100th Ave. 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: Tigard,OR 97224 601 amps to 1,000 amps 301.04 2 Phone:(503 )504-4087 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: rkeast1@hotmail.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 IX) APPLICANT ❑ CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name: Premier Solar NW above service or feeder fee, 7.42 2 each branch circuit Contact name: Robert M. Rathbone B.Fee for branch circuits without 12399 NW Waker Dr. service or feeder fee,first 56.18 2 Address: branch circuit City/State/ZIP: Portland,OR 97229 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(503 )828-9500 Fax: :( ) Each manufactured or modular 67.84 2 dwelliEmail: rrathbone@? remiersolarnw.com Reconnectonyeandorfeeder p Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name: Premier Solar NW Sign or outline lighting 67.84 2 12399 N W Waker D r. Signal circuit(s)or limited-energy El See Page 2 2 Address: panel,alteration,or extension. City/State/ZIP: Portland, OR 97229 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/lir Phone:(503 )828-9500 Fax:( ) Investigation(1 hr min) 90.00/hr Email: cbarry@premiersolarnw.com lndustrialplant(lhrmin) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lic.: 218826 Electrical Lic.: C1540 Suprv.Lie.:6533S specifically listed(9:hr min) ELECTRICAL PERMIT FEES � 1Suprv.Electrician signature,required: ' ,L.,./ Subtotal: Print name: Tim Oliver Date: 2/9/21 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Date: 2/9/21 days after it has been accepted as complete. * Number of inspections allowed per permit. I:\Building\Pernuls\EI.C_PermitApp_ELR ERE.doc el.06,17/2015 440-4615TOI/OS/COM/WEB Electrical Permit Application—City of Tigard Wage 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Descripdon I Qty. I Each I Total Fee for all residential systems combined: $75.00 1 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less o0.7o z 5.01 to 15 kva X 133.56 133.36 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0,0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(1/2 hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system: $75.00 Subtotal(Enter on Page 1): " (SEE OAR 91 8 309 0000) Number of inspections allowed per permit. Check Type of Work Involved: ❑ Audio and Stereo Systems n Boiler Controls n Clock Systems n Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems n Landscape Irrigation Control* n Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1''Building\Permits\ELC_PcrmitApp_ELR_ERE.doc Rev 06117,2015 D City of Tigard ` FEB i. :i 2021 Building Division ' - 13125 SW Hall Blvd,Tigard,OR 97223 CITY OF TIGARD Phone: 503.718.2439 Fax: 503.598.1960 BUILDING DIVISION TIGARD Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 14950 SW 100th Ave. City: Tigard Zip: 97224 Owner's Name: Richard and Erin Keast Date: 2/9/21 Contractor's Name: Premier Solar NW CCB #: 218826 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation I] Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? x❑ No OS SC or ORSC for design requirements. Wind Exposure Is the wind exposure El Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes E Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for x❑ Yes the prescriptive path. above ❑ No 1 I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Is the construction material wood and does x❑ Yes Type of If"Yes", qualifies for Construction the construction qualify as conventional light ElNO the prescriptive path. frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. ❑ Yes If"Yes", qualifies for the prescriptive path. El No Roof framing members Is the spacing 24 inches or less? If"Yes", qualifies for Nominal lumber. x❑ Yes the prescriptive path. ❑ No Is the combined weight ❑x Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ❑x Yes If with Section 305.4(3) of "Yes", qualifies for ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ® of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ❑ of composition shingle. Is the roof mounted ❑x Yes Connections of solar assembly Ithe solar assembly connected to roof No the"Yes",prescriptive p for framingor blockin ❑ path. to the roof g directly? 2 I:Building/Forms/PhotoVoltaic-Checkli st02-01-11.docx Is the gauge 26 or less? ❑ Yes If"Yes", qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum #10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. 1/z"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof x❑ Yes the prescriptive path. surface. ❑ No 3 1:Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: Panasonic Model Number: VBHN325ica03 Listing Agency: uL 4 1:/Bui lding/Forms/PhotoVoltaic-Checklist02-01-11.docx