Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
JoL N'nm e.E nt sni Gammon IL'v ..:.Pu.i,i f:'ni c2o11-cot 2 TAN " PrpmrdHya TAU VA , YY" -tkscl RECEIVED 9 3:bi MAR 0 8 2021 Variable Air Volume Single Duct Cl7YOFT1GARD !ON Unit model Primary inlet Design cooling airflow Min cooling airflow Trane Supplied Controls VCCF(Cooling Only) 6"(152mm) 200 cfm 60 cfm UC210 DDC-Basic(cooling only) hit'. APD @ cooling airflow 0.040 in H20 > Cooling inlet velocity 1019 ft/min Valve heating airflow 60 cfm {it r Connection side Left �` aim Unit Insulation 1"matte "J II Elevation 0.00 ft Operating weight 16.0 lb , dtAihh... MIL Air Leakage Class Standard Air Leakage l Actuator Standard actuator DTS 8 HW Valve Harness Duct temperature sensor-factory mounted Accessory Options. Disconnect Switch Disconnect switch Power fuse Power Fuse Transformer 277/24 volt transformer Acoustics°.- Max inlet SP Discharge transfer function Radiated transfer function 0.750 in H2O AHRI 885-98/08 AHRI 885-98/08 Mineral Fiber Sound Path 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz NC Discharge valve 60 dB 55 dB 46 dB 42 dB 38 dB 37 dB -1 Radiated valve 47 dB 42 dB 34 dB 26 dB 25 dB 22 dB -1 Note:Sound power level in dB re 1 pW.Acoustical data obtained in accordance with AHRI 880-11 Note:Ducted Discharge noise criteria(NC)estimate is calculated using the following transfer function:AHRI 885-2008. Note:-1 =NC level is less than 15. Warranty r` r 1st year labor warranty whole unit 2021-03-05T15:51:47 Page 1 of 6 E .!,,,,,,,.1 Name.tn!tm.»y Common-IDnveway Finanre SOtI 0 dlmtlBy. Umtl vAV-1 guar 1 6 t 23,4. AIR VALVE AIR n lit' FLOW ■ SLIPCRIVE �. i & CONNECTION TOP VIEW II VT 7. i0. Customer Notes 1.AS Inlet is centered in unit front panel 2.3l0 8 Drive discharge outlet stantlerd. 3.Minimum of 1 5 duct diameters of straight duct required at inlet for proper flow reading. 4.Allow 36"on control side for servicing. 6" 91/2' 5.Uni is field-convedible from a lee-hand connection(shown)to a nght-hand by rotating unit. Approximate 16 0 6 Dry Weight BACK VIEW Weights reflected may vary t5.0 lb based upon options selected. Page 2 of 2021-03-05 16:51-.472 Job Name Embassy Commons(Driveway Finance P01( Prepared By. Unit Tay VAV-1 Quantity 1 277/60/1 L1 N 0 I I T I I I I I I O IGI Control Options Wiring • To Control Boa 24 VAC A\WARNING HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. FAILURE TO DISCONNECT POWER BEFORE SERVICING CM CAUSE SEVERE PERSONAL INJURY OR DEATH /N CAUTION USE COPPER CONDUCTORS ONLY! Customer NOt@5'. UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF 1 Factorymstalled CONDUCTORS. FAILURE TO DO SO MAY CAUSE — — — — Optional or installed by others DAMAGE TO THE EQUIPMENT Page 3 of 6 2021-03-05 18:51 47Z T/?/4NE, Job Name.Embassy Commons(Driveway Finance 301) 0 Unit Tag.red VbA Unit Tag.VAV-t Quantity 1 ror00AE FY x.015[Oxxf<r Q __ , r PBI OGLE CERT NE ✓ 1 OfLE[iPK NEAT, - it v RIVAL ." T DRIER - g'(Y�PW 4 OPEN SPRNO [��IIVKNC R a m I SCREW `w3 CONDE ACTYROR PER 24VAC BOI IZ Q wCl -JUNK COW OPTIONAL nfi NEC O ASS-2 F.pc CONTROL CIRCUIT 6 t1Z)R NxONNECT SWRCX LSPPCIO RETURN DRNPERACTU WOE J ( LOACo WITHOUT O•RN IT: (1MTHOUT HEAT) W1RILLP6ONANL OCY,S INTERFACE OPTIONAL F40TaLTOPVIxSTPLIEO OPTIONAL wcl OW I x fa,,p NS TSB L J Q _ Y I ? INOPEND O ] M] CLOSE ACTYROR OPTIONAL W ______ 1RINSF OREIER L STNIDM0OWPER ACTUATOR J -1 U I T LED FUNCTIONS 401E no 1.SQ2VICE 6.B]I IL U<1N ONO 2.GREEN STATUS 1 802 ONO MT) ANALOG 3 RED STATUS B ED3 NVIC UII 21Mc DAMPER 4.IMC TRANSMIT 9.ACTUATOR CLOSE r2.0RC511) 3.10 NM, Aryl/ATOP00 SC- M11DpI 5 AMC RECEIVE IC ACTUATOR OPEN24VACOIN um MUD) M10GI On) No. rill I �11AS LP UHl LC/ MALOOOAMN0.KrVTOR 30E3D O 1 '. 0 L r "1 IEOE \N-P.., ,,,LEG! INC„p ,1 N Ju 0 0 1 00 0 MAC IF 01 II f0 7 5 3 1 t 21VFC VlE) PROP. 0▪11 001 ONO ANALOG W ER GUI] 0000 SW�4IV] O It 10 OMx OInCMF2 1 b1avY VALVE ,a ® CORA c= w O C-� nExmF Nro. use I,J Wx JMo2 < DPwONJLMI FIELD w301010 J21Q L PROPORTgE4LANALM WATT P VALVE OPrgMKP4lO RIVALLED UC21� r.::}En Jffi OTT L 51011&DISPLAY ZONESENSOR J ✓ - c"' f w11) M1On 3Aw[1d31 N`PC POOPWA." hP U]P Un SWE ELD10 14E11 1J31 CLOSE M a, Bp2112N 2NC O 00 T (131 N NJ231 OPEN ANEW • I c1—NLE 1)n 0 IOC TOR YIN MLA) LA)iNONYINISS wlX i -IP1,.h !OS 0 01 0 0 10ONAL 1TLFD 1 L PROPORTIONAL WATER VALVE J .fir-1F�1b AC p•1 I0ME 6lMSOP 1 11121 BO2 WE CONY IACP -I }Z 444JJJ" ✓ 'PV R l�f;p1 1� 1ij3tE at moll LTD. ON-Drf PNSINCI I NL I IiilfOE �Q BDlU2]) WR24VACWAN WSDUCtR 0 2PMC1J31 2LVK J 1200MC OPTIONAL FIELD ISMY/JI OUT BN ail, 1111p IS) L INSTALLED IOME SENSOR / LI awl OPTIONAL-01W WATER VALVE � .i o r MTIR 1 N-0fiWR[P VAST J ® lI1F D6 Val USM "3 AIC�,s A A ' I ,1p$�MC ✓ ® B p'v' "IIIL__PPP .�=T a1^�J�+I 21V S NWCD10) �'' 4 '0 #NR 2iwC ke.12 OPTIONAL CO2 WA • D YETI Tt2ONE 1`!'1(��/Sp/�7 ,yy�, {��,y�,y/71 Jt61IS A Y OAT TEMP'Olson 9FJAOR 011T V uv di TALI Jt�`-�iJ�l 1�'�Pc'� L J 1 OPTIONAL FIE ID IYRTJi120 0 CA A 0 r©41 00101(E, ]BD STO L CO2 SENSOR J BD21Rn }xD STO NFTEa STISE r 1 CONTROL 80X BmN2l1 19r5TD CONTACTOEIS) a ) 2FWC.rsw R or NVAC(11N NOTE: 2P,NCM,y) 2avAC Non Yu4COIL 0(COMMON( OP etc cONrz[rl Ni MI IU1Tl E FACTORY WIRING OPTIMAL FYLO errACTORYWSTALLED BA RENRWRING) 2 FIELD WRING J W 1(A L ICECTRK XERFR o NOT CONNECTED OPTIONAL OR ALTERNATE WRING OPTIONAL Ye ID INSTALLED a PARE WIRE BIOS OR IM"OUICK CONNECT T62MNALSREOUREO FOR ALL FIELD CONNECTIONS T11. a1pWc0 L OCCUPANCY SENSOR J QZONESENSOR TERMINALS I(-)MD 2IXI REOIYRE SHIELDEOTWISTED OMR AD2L1N WRING FOR CONAINICATIONS JACK EQUIPPED ZONE SENSOR OPT10N roe IONO OND SUIT C x1K1011 S OOLO STATE 5) sC NDACORIONAL WRING REQUIRED FORNGNT SETBACKOVERRDE ION/CANCEL) ONI*MSC BR Q IF LNR MOUNTED TRANFORM91 IS NOT PROVDED,POLARITY FROM UNITTO UNIT MUST BE OPrgnAL PEW a PACTORY*Su1140 MAINTAINED TO PREVENT PERMANENT DAMAGE TOCONROT SOARO IF ONE LEG OF 24VAC SCR ELECTRIC NEATER J SUPPLY IS GROUNDED.THEN GROUND LEG MUST BE COIFECTW TO.1 IS. L ci CONTACTORS 1RE21 VAC 12VAMAXICOL(MERCURY CONTACTORS(IOVAMAACCIL r OPTOMALOCTONYINSTALJED (MAGNETIC CONTACTORS( WIRE LE SSIOXE SENSOR RECEIVER `J �I OPTIONALFU SE DISCONNECT SWITCH 6TRAJSFORMER LOCKED N CONTROL BON FOR COOLNG& HOT WATER UNITS.LOCATED N HEATER ON ELECTRIC HEAT LINTS ILNMC TRANSFORERWRE COLORS 120V-W.206V•R.2YN-0.}MTV BR.INV MUSK RIVALS waI 575V•R.790V.R.220V-R.347V•R 410 Y 11111 2011E TEMPw AS,WI B. SCREW TERMINI ADAPTERS REWIRED FOR 67.UII.U12.NEC 8LNN ONO Nx A VN ZONE SET PT M21131 Q TO USE A3 WITH ASUPPLY MR SENSOR FOR AJTOCNANGEOVER. REASSIGNMENT OF 83 TO SAT WIT H TU IS REOURED (El ZCIE SENSOR TERMINALS SAND 7 REQUIRE MELDED TWST®FAIR L J WIRING FOR OPTIONAL USE OF COMMUNCATIONSJACIL 1i. 24VOL REWIRED FOR TREE SCR ELECTRIC HEAT MODULE 2021.03-05 18:51:47Z Page 4 of 6 General Unit Information The unit casing is comprised of 22 gauge galvanized steel. Outlet connection is slip and drive. Agency Listing -The unit is UL and Canadian UL listed as a room air terminal unit. UL Control # 9N65. All Trane terminal units are AHRI 880 - 98 certified. General Unit Clearance Allow adequate clearance on control box side of unit to meet NEC. A minimum of one and one half duct diameters of straight duct work, upstream of the air inlet connection, must be present for optimum airflow measurement performance. Upstream duct work should be the same diameter as the primary inlet connection. Allow access to the bottom of unit if Optional Bottom Access Door is selected. 1"Matte - Faced Insulation The interior surface of the unit casing is acoustically and thermally lined with 1" 1.00 lb.cu. ft. [16.0 kg./cu. m.] composite density glass fiber with 4.0 lb. cu. ft. [64 kg./cu.m.] high density facing. The insulation is UL listed and meets NFPA-90A and UL 181 standards. The insulation R-value is 3.85. All cut edges of insulation are completely encapsulated in metal to prevent erosion. Air Valve Size - 06 Air Valve is 500.0 cfm 6"inlet. Air Valve Round The air inlet connection is an 18 gauge galvanized steel cylinder sized to fit standard round duct. A multiple point, averaging flow sensing ring is provided with balancing taps for measuring within +/- 5% of unit cataloged airflow. An airflow versus pressure differential calibration chart is provided. The damper blade is constructed of a closed cell foam seal mechanically locked between two 22 gauge galvanized steel disks. The damper blade assembly is connected through a cast zinc stub axle and shaft supported by self lubricating bearings. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over stroking. At 4.0" w.g. air valve leakage does not exceed 1% of cataloged airflow. Slip & Drive Connection A slip and drive connection has two straight flanges on the top and bottom, and two drive connections on the left and right sides. This is a standard option on all VAV single duct terminal units. Toggle Disconnect Switch (for VCCF &VCWF) A switch, installed in a unit mounted controls enclosure, which breaks both power legs within the control box. Control Fuse Replaceable fuse on primary voltage hot line. Line Fuse -VCCF and VCWF For VCCF and VCWF units, optional fusing breaks all energized lines of incoming power. Control Transformer The 50 VA transformer is factory mounted in a unit mounted controls enclosure with 7/8" knockouts to provide 24 VAC for controls. D.D.C. Floating Point Actuator Trane 3 wire, (open, close, common) 26GA when 6-pos amp connector is used for Tracer UC210, W550, or VAV UCM, otherwise 18GA wires are used. 3.4 VA, 1.7W, 24 VAC, 50/60 Hz. Quarter turn control actuator with linkage release button. Actuator has a constant drive rate independent of load, a rated torque of 35 in-lb, a 90-second drive time and is non-spring return. Travel is terminated by end stops at fully opened and closed positions. An integral magnetic clutch eliminates motor stall. An integral 3 screw terminal block is provided for field wiring. Operating temperature 32.0 F to 125.0 F. 2021-03-05 18:51 47Z Page 5 of 6 TRAM Job Name.Embassy Commons(Driveway Finance 301) f/' Prepared By Unit Tag.VAV-1 Quantity.1 DDC Controls Option DD01, DD11, DD41 & DD71 Basic Operation: Cooling Only Control (No Remote Heat) (DDC/UCM) A voltage signal from the zone sensor indicates the zone temperature is used by the unit controller to determine an error from the set point. This error, as well as primary flow differential pressure, is used to determine damper position within minimum and maximum cooling airflow set points. As the zone temperature drops to the heating set point, primary airflow is controlled to minimum heating flow set point. Factory Mounted DTS (VCCF) Factory Mounted internal to the Single Duct Terminal unit. The DTS is a 4" 10k ohm thermistor and is factory mounted into the Single Duct Terminal and is factory wired back to the Trane controls. 2021-D3-05 10:51:47Z Pegs 6 of 6 0 TRANE VAV Fan Powered Terminal Unit Unit Overview-FP-1 Unit model Primary inlet Design cooling airflow Min cooling airflow Trane supplied controls VPEF (Parallel Fan Electric g^(203mm) 600 cfm 165 cfm UC210 DDC-Basic(Electric Heat) heat-staged) APD @ cooling airflow 0.106 in H2O li Cooling inlet velocity 1719 ft/min � ---- Valve heating airflow 165 cfm Unit heating airflow 300 cfm Fan airflow 135 cfm -`- . " Controls connection side Left hand Unit insulation 1"matte faced Outlet connection Flanged connection � ��} ' Elevation 0 1 Operating weight 10.R 0 lb ��\\_ 1-114 Downstream SP 0.250 in H2O Primary EDB 55.00 F Fan size 02SQ Plenum EAT 70.00 F %of fan range 3% Room heating setpoint 68.00 F Fan TSP 0.251 in H2O Room heat loss 7.16 MBh Fan power 0.125 hp Unit LAT 90.00 F Motor voltage 277 Coil heating capacity 9.20 MBh Motor type Single speed w/SCR Coil EAT 61.75 F Full load amps 10.42 A Coil LAT 90.00 F - Min circuit ampacity 13.03 A Electric heater voltage 277/1 Max overcurrent protection 15.00 A Electric heater kilowatt 3.0 Electric heater stages 2 ,Eery iR"'1T-x Electric heater control Solid State Relay(SSR) ` ^^."'*"''",."a,: Electric heater air flow switch Electric heater air flow switch Actuator Standard actuator DTS&HW Valve Harness Duct temperature sensor Disconnect switch Disconnect switch Power fuse Power fuse Max inlet SP Discharge transfer function Radiated transfer function 0.750 in H2O AHRI 885-98/08 AHRI 885-98/08 Mineral Fiber Sound Path 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz NC Discharge valve 65 dB 60 dB 56 dB 52 dB 47 dB 44 dB 17 Radiated valve 62 dB 54 dB 49 dB 44 dB 38 dB 32 dB 25 Discharge fan 59 dB 51 dB 51 dB 43 dB 38 dB 33 dB 15 Radiated fan 64 dB 55 dB 53 dB 50 dB 43 dB 36 dB 28 First year labor warranty 1st year labor warranty-whole unit 2021-03-05118.09:26 Pace 1 616 • TRMU Ure lob plaed NameEy.Embassy Commons(Driveway Finance 301) Um)lay Duanlily 1 Unit Sae VPEF0802SO Nominal 8'De.l 4"Depth Valve See&Depth Nn Nominal Fan Sze on()Fan . Rher Sze 14'020"o 1"lOTY 1) TOP VIEW 5" --I -- 1 eiR AIRFLOW D NOTES. 16 v2 $ m y, 1.Allow a minimum 6"plenum Wet clearance for un-ducted installations I 30, 2 Filter is secured in fitter Inane located in unit nlel. 1. J 3.for Motor access,remove bottom screws on hanger brackets to slide panel as shown ei drawing. 22, 9 4 See Instdlelion Documents for elect hanger • 11 D bracket locoten . i g V 5.Air valve centered between lop&bottom panel. HEATER 6" ilq 6.Heating col un-insulated Exlemal insolatun may RIbe field supplied and Installed as required. 'IV PANEL SLIDES FOR MOTOR ACCESS 7.All high&low voltage controls have same-side AIRFLOW NEC jumaback clearance DISCHARGE OUTLET 8.Allow 48'of straight duct downstream of unit before first runel and inside of the duct should be equal discharge size. i 9 Terminal box access door is side hinged.ANow for 5' —1 40' clearance. 10.A 4 wire power supply requred for 48013&5753 single point connection units. it - 151/2" 74- I Approximate t°� 20 Dry Weight 1200lb Weights reflected may vary ±5.0 lb based upon options DISCHARGE VIEW selected. 2021-03-05 18:09282 Page 2 of 6 e �/ �i• Job Name.Embassy Commons IDnyeway Fivanre 301 i Prepared BY. Una Tag'.FPT Quantity 1 • • 277 Von,1 Phase LI N Iill N IGl Heater Control Wiring n WARNING HAZARDOUS VOLTAGE!. DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. FAILURE TO DISCONNECT POKER BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH A CAUTION USE COPPER CONDUCTORS ONLY! UNIT TERMINALS ARE NOT DESIGNED Customer Notes: TO ACCEPT OTHER TYPES OF t Factory nstalled. CONDUCTORS FAILURE TO DO SO MAY CAUSE — Optional or insteled by others. DAMAGE TO THE EQUIPMENT. 2021-03-05 18:09:26Z Page 3 of 6 X 0 Job Name Cmnassy Commons IDi[veway I-Inane 3011 TICAPIFlegpaed ay Dml Taa.FP 'Quantity 1 r 1 r 7 DINS 21M4 TO a rN10CXt11 -I Y ry OPEN SNOW A�MC°m1 p OR MC- 15[E3,pNl. TRANSFORMER �MA MACIAS) 011 tl]IJ31 AMR) CLOSE RfNPM rM] DwrER z 0111 wc. AI L 033 ACTUATOR WCI ] LINK- OFT LL Yltl Jt5 TO A-' EAC OPTONAL FACTORY 1E13) �T LSPRW PS D RETURN DAM R ACTA RCA J M4iµLEO D'q 00 00 0 PSC PAN 0.l LAD MA II II 1 S 3 ] 1 r , WEIELE SS C 000YXICAT1N o-5 MTERFACF 'y OPTIONAL PACTORYIxSTAIII O R n Dgµ DISPLAV0)100 ZONE SEX SOR pM1 DAVK WC! ONA WICOM BY JACK PM. OPCX ST.WDNO L J REMOTE ATC {yC D1YP[R Q p IN] [LOSE ACTvnraR OPTIONAL FIELD INSTALLED r - T L J L__0101TK DaSENSOR_ NROO SENSOR _J L STAXOKIO DPMrEs ACTUATOR J V I- MC) U+1J 2)1 IL NYC. I1) LW FUNCTIONS WI)AZ al ONO I SERVICE E a01 FM NIL ORD gen 2 GREEN STATUS 1.202 ORVAL IRK QAWC, DAMPER 3 RED STATUS 6 RD3 N 0 01 0 0 MI(MI za0 V4P KTUATM •RAC TRANSMIT 9 ACTUATOR CLOSE ry 1Ea I] Z 1 E.MC RECEIVE ZONE See sag 1D ACTUATOR VALOUR.JACK REMOTE ITS L ANALOG DAM PER ACTUATOR J !D]8 LIES QQ r 1 1T01 V A? C1111XC Jn �P P� MC J1i JtY UNK I,T OPTIONAL FIELDELO DAWC 11101 MAC PROP �01 (�J�p ]'} L INSTALLED ZONE SENSOR J ONO QM ONO ANALOG Ou¢ C\[S ] MOO- O Mt UM 3'PO VW yKVE ✓0 V�O� ID: Jb A r Dar Na 1 Y1 use NU WI OPTIDNPLFULNINSTALCED - wz RR L PROPDRTpNALMWOO WATT WLLIE J OM lean UC210 JboD. U Q r _ ❑� O JILT NV pop JT Ult SW] LfD10 OPTIONAL CLOSE WTE0. L AT MAP SENSOR ATLE J OPIM1 3NIE MJU91 rswMAX TX TORY PISTALIED HARNESS MTx ID IE,O,.B—n r� l FOLD MS3KLEO 023 405 �'I ]0.0 S16 L PROPORTIONAL WATER VALVE J 1IOVAC BD1U1St 1YOET0 33..�1 Jp MOONEATER STOOE r 1 �]};-X{F 13+®3 1ST STO. caITACTORIUI B031O31 900ON t OFF!!VALVE �OVICEp3 0 Lf DI �1E01 NVACwY33J1 IWCNOT 31YA%FOVL TAVACOZZ INAMM \ /i] JN MAC OPTIONAL FRIO ArFACTOSYW STALLED \\ OUT4XK_ BX �}I R L ELECTRIC NEATER J OPTIONAL FIELD IMSTµ1E0 / ,I c lltD^901 OR ON-OFF WATER VALVE q Fps iiisq rOTgXKpKTORYINSTKIfp L J Oe� . y l 'LF D6 WIRE LE 33 ZOO YXSORRF CO VIER Jfi 1al�y LA1JI 13la 'L� S.111111 r yR X3�y® , .LIo,T 'UJ�T71. „K L A i1 4 IJi-1[T TA -J II bVµ 1X BLNWC YTSI py NVK Yl1U {{p���1vpMp,1 -,f 1fI`^'L1 1g1v��fI1 Jl) ENDjtj UtTI o J3 T\ 111\�I 1�,1 Y U ORR Ur VAC ZONE ONO-W mall ptttl12 OR OM 0 333, Kt�NE ! irnfff Al 0. OHO UZI ��I I13o Y p fi OTT Y UO /Tl UM JI \ 3, ZONE SET PT fat OmONKF[1D INSTALLED ® O L COE SENSOR J L J CONTROL BOX r R IXOTI 1LMK f116] O ATOM MOM NOTE rQ OR INC CONTACT) 1Y.1) 1 FACTORY WRING Mbn4 O-IOWLc 0N)se aelll MI INN �}p MI OEN FIELD WRING GpO ORv SULY STATE NOT CONNECTED OPTIONAL OR ALTERNATE WRING IJAIDMO CDxTNTORryI OPT OCCUPANCY INSTALLED 2. SANEWMRE ENOS CR 3A'Ou1CK CONNECT TERMINALSW ALEN RERED FOR L Fan CONNECTIONS Y1p•xIVDC PR L DccuPAxcvxxsDR J Q ZONE SENSOR TERMINALS,NAND 2R7I REWIRE WELDED TWISTED FAIR DPnp1AL Fie en At-FACTORY INSTALLED WIRING FOR COMMUNICATIONS JACKEOUFPED ZONE SENSOR OPTION. MR[IE011110 NEATER L J NO ADDITIONAL WIRING REQUIRED FOR NGMTSETEACKOVERRWE(ONICANCEL) Q TRNISFroMFR PROVIDED RI ALL UNITS CONTACTORS ARE 21 VA: 12VAMAXICQL(AERCIIRYCONTACTORS)IOVAMAKICOIL MAGNETIC CONTACTORS) 241.14c REQUIRED FOR T9RE SCR aECTRIC HEAT MODULE E. 9CREWTERMOIAL ADAPTERS REQUIRED FOR&1.U11,U12 WC 6L14K Q TO USEN3 Wall ASUPRYAIR SENSOR FOR AUTO.CRANGEDVER. REASSIGNMENT OF N3 TO SAT WTNTU IS REQUIRED 1B., 1 ZONE SENSOR TERMINALS E AND 7 REQUIRE SMSDEOTW STED OUR WRING FOR OPTIONAL USE OF COMMON!CATIONSJACK 2021-03-05 18:09'.243Z Page 4 of 6 TRANS" , ;;N; General Unit Information Casing - The unit casing is 22 gauge galvanized steel. Outlet duct connection is flanged. Total metal encapsulation of all insulation edges. Hanger Brackets provided. Side access is provided. Filter- A filter is provided on the plenum inlet. Agency Listing - UL and Canadian UL listed as environmental air terminal unit. UL Control #9N65. All Trane terminal units are AHRI 880 -98 certified. General Unit Clearance Leave a minimum of 36" on control box side of unit for adequate service access. Allow at least 12" on remaining sides for unit clearance. A minimum of one and one half duct diameters of straight duct work, upstream of the air inlet connection, should be present for optimum airflow measurement performance. Upstream duct work should be the same diameter as the primary inlet connection. Electrical Installation Information For electrical connections, consult field wiring section & equipment IOM. IMPORTANT: Field Wiring Most fan-powered VAV terminal units with electric reheat require a neutral connection from building power, however, some configurations do not. In order to prevent a building wiring issue once the boxes are installed, the wiring diagrams and field wiring installation for each unit MUST be checked to determine whether the neutral is required or not required. 1" [25.4 mm] Matte - Faced Insulation The interior surface of the unit casing is acoustically and thermally lined with 1", 1.5 lb/cu. ft, composite density glass fiber with high density facing. The insulation is UL listed and meets NFPA-90A and UL 181 standards. All insulation options will meet the 25/50 smoke developed and flame spread rating (per ASTM E 84 and UL 723 and CAN/ULC S102-M88) Meets NFPA- 90B. No exposed edges of insulation [complete metal encapsulation]. The insulation R-value is 3.85. All cut edges of insulation are completely encapsulated in metal to prevent erosion. Air Valve & Fan Description (Parallel) (Series) The air inlet connection is an 18 gauge galvanized steel cylinder sized to fit standard round duct. A multiple point, averaging flow sensing ring is provided with balancing taps for measuring airflow within +/- 5% of unit cataloged airflow. Also provided with each unit is a calibration chart indicating airflow versus flow sensor pressure differential. The damper blade is constructed of a closed cell foam seal mechanically locked between two 22 gauge galvanized steel disks. The damper blade assembly is connected through a cast zinc stub axle and shaft supported by self lubricating bearings. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over stroking. Air valve leakage <1% at 4". 0802SQ Air Valve/Fan Combination Size (Parallel) 8" Inlet designed for up to 900.0 cfm. Fan is 510.0 cfm. Fuse Any electric heat unit with a calculated MCA greater or equal to 30 will have a fan fuse provided. Factory Wired/Field Mounted Auxiliary Temperature Sensor The auxiliary temperature sensor is used in conjunction with the Trane DDC controller to sense duct temperature. When the DDC controller is used with a Building Automation System, the sensor temperature is reported as status only. When the DDC controller is used in a stand-alone configuration, the sensor determines the control action of the UCM in a heat/cool changeover system. The factory mounted option eliminates field wiring by providing the sensor pre-wired and zip-tied to the control box, where it can be easily cut loose and mounted in the duct. Motor Single Speed, direct drive induction, permanent split capacitor type. Thermal overload protection provided. Motors will be designed specifically for use with an open SCR which is standard. Motors will accommodate anti-backward rotation at start up. Motor and Fan assembly are isolated from terminal unit. 2021-03-05 15:09.26Z Page 5 of 6 N Na,m [.n C.mnr.: f r-Fwm-Hn i..e..t01 0 MANE' r d ; FP Ora q 1 Electric Heat Coil Factory provided and mounted. Resistance open-type heater, a disc-type automatic thermal primary safety device and manual reset load thermal secondary device. Heater element material is nickel- chromium. The heater terminal box is provided with knockouts for customer power supply. Terminal connections are plated steel with ceramic or phenolic insulators. All fan-powered units with electric reheat are single-point power connections. SCR-Variable Fan Speed Control Switch The SCR speed control device allows the operator infinite fan speed adjustment so the fan output may be modified to achieve exact CFM requirements. Solid State Relay (SSR) Contactor An SSR electric control device for use with DDC and Analog unit controllers. The SSR serves both as a substitute for magnetic contactors and a RoHS compliant alternative to mercury switches. The SSR allows silent on/off control of each stage of electric heat when heat is needed for zone temperature control. Power Disconnect Switch (for VSEF & VPEF) A factory provided interlocking door disconnect switch located on the electric heater control panel. Airflow Switch An air pressure device designed to disable the heater when the unit fan is off. Power Fuse Fuses provided on all energized lines of incoming power to interrupt circuit overcurrent conditions. Flanged Connection A rectangular opening on the unit discharge to accept a 90 degree flanged duct work connection. D.D.C. Floating Point Actuator Trane 3 wire, (open, close, common) 26GA when 6-pos amp connector is used for Tracer UC210, • W550, or VAV UCM, otherwise 18GA wires are used. 3.4 VA, 1.7W, 24 VAC, 50/60 Hz. Quarter turn control actuator with linkage release button. Actuator has a constant drive rate independent of load, a rated torque of 35 in-lb, a 90-second drive time and is non-spring return. Travel is terminated by end • stops at fully opened and closed positions. An integral magnetic clutch eliminates motor stall. An integral 3 screw terminal block is provided for field wiring. Operating temperature 32.0 F to 125.0 F. DDC Controls Option DD04, DD14, DD44 & DD74 Basic Operation: On/Off Staged Electric Heat (Normally Open Outputs) (DDC/UCM) (Parallel Units) A voltage signal from the zone sensor indicates the zone temperature is used by the unit controller to determine an error from the set point. This error, as well as primary flow differential pressure, is used to determine damper position within minimum and maximum cooling airflow set points. As the zone temperature drops to the heating set point, primary airflow is controlled to minimum heating flow set point. The fan operation is intermittent in both modes. Staged electric heat is energized. 2021-03-05 18.0926Z Page 6 of 6 Fan size 02SQ Parallel 025Q Fan Curve - Single Speed with SCR 0.6 p 0.4 N • t a 0.2 0 200 300 400 S0 - 600 Airflow Rate (cfm) Operating Range — SCR Max SCR Min f Operating Point