Plans (2) •--r`'^ ► 3 FA �N S 14<?o t 61 PC_ E x /2 RECEIVED AUG 1 1 2020 CettiP1 H BUILDING use Z. 4)(6, VI/ /3 G' P50N C AP 13-9 36- ti%e� C2NECr Wl / H 6FAN(S) S,PA� iYG 3Fr uorzeM ca-orrNs < i6 " Mix. cooi1N (; S . 2 '% 2_01 x 2i-p " oEEP Er 'a 46 #1 & 4 Pr P6 20 TABLE 1 If you have a and you have then you and the and they can and the footings"D" beam"B"that is: posts"C" can only minimum size be spaced a supporting the posts supporting the span the joist you can maximum of: must be a minimum size beam spaced: joists: use is: of (WxWxH): 4x8 or (2) 2x8 6'-0" apart 6'-0" 2x6* 24" apart 13"x13"x24" deep or 14" diameter x 24" deep 4x10 or (2) 2x10 8'--6" apart 6' 0" 2x6* 24" apart 15x15"x24" or 17" diameter x 24" deep 4x12 or (2) 2x12 10'-6" apart 6' 0" 2x6* 24" apart 16"x16"x24" or 18" diameter x 24" deep 4x12 11'-9" apart 6'-0" 2x6* 24" apart 18"x18"x24" or 20" diameter x 24" deep 4x8 or (2) 2x8 6'-0" apart 8'-0" 2x6* or 2x8 16" apart or 24" 14x14"x24" or apart 16" diameter x 24" deep 4x10 or (2) 2x10 8'-0" apart 8'-0" 2x6* or 2x8 16" apart or 24" 16"x16"x24" or apart 18" diameter x 24" deep 4x12 or (2) 2x12 9'-6" apart 8'-0" 2x6* or 2x8 16" apart or 24" 18"x18"x24" or apart 20" diameter x 24" deep 4x12 10'-9" apart 8'-0" 2x6* or 2x8 16" apart or 24" 18"x18"x24" or apart 20" diameter x 24" deep 4x8 or (2) 2x8 5'-6" apart 10'-0" 2x8 or 2x10 16" apart or 24" 14"x14"x24" or apart 16" diameter x 24" deep 4x10 or 12) 2x10 7'-6" apart 10'-0" 2x8 or 2x10 16" apart or 24" 16"x16"x24" or apart 18" diameter x 24" deep 4x12 or (2) 2x12 9'-0" apart 10'-0" 2x8 or 2x10 16" apart or 24" 18"x18"x24" or apart 20" diameter x 24" deep 4x12 10'-3" apart 10'-0" 2x8 or 2x10 16" apart or 24" 20"x20"x24" or apart 23" diameter x 24" deep 4x6 or (2) 2x8 5'-0" 12'-0" 2x10 or 2x12 16" apart or 24" 14"x14"x24" or apart 16" diameter x 24" deep 4x8 or (2) 2x10 6'-6" 12'-0" 2x10 or 2x12 16" apart or 24" 16"x16"x24" or apart 18" diameter x 24" deep 4x12 or (2) 2x12 8'-6" 12'-0" 2x10 or 2x12 16" apart or 24" 18"x18"x24" or apart 20" diameter x 24" deep G� . __._.____._,,_� 12'-0" 2xT or 2x12 16" apart or 2d" 2 'x 1Yx24" or ;k, T ... ._ apart 2 diameter x 24„ dee 4x6 or (2) 2x8 4'-6" 16'-0" 2x12 16" apart 15"x15"x24" or 17" diameter x 24" deep 4x8 or (2) 2x10 6`-0" 16"-0" 2X12 16" apart 18"x18"x24" or 20" diameter x 24" deep 4x10 or (2) 2x12 7"-6" 16'-0" 2X12 16" apart 20"x20"x24" or 23" diameter x 24" deep 4x12 9'-0" 16'-0" 2x12 16" apart 22"x22"x24" or 25" diameter x 24" deep 2x6 joists cannot be used where a guardrail is required. 6 • DECK DESIGN GUIDE