Loading...
Plans RECEIVE_.. JAN 11 2C 1 CITY OF Tlutir<.j BUILDING DIVISION Building Plans for City of Tigard Building Permit Application Customer: The Fountains at Summerfield condominiums HOA 15685 SW 116th Ave., #105 VALIDITY OF PERMIT Tigard, OR 97224 THE ISSUANCE OF A PERMIT Contact - Paul Brock, 858-212-9105, pbrock987@gmail.com BASED ON CONSTRUCTION DOCUMENTS AND OTHER Contractor: Jon Erickson, 503 730 9220 DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM jon.evenjobs@gmail.com CCB 162397 REOUIRI:SG THE CORRECTION OF ERRORS. OSSC 105.4 Scope of Work— Repair Decks • Replace perimeter joists with PT OFFICE COPY • Repair joist and soffit dry rot CITY OF TIGARDG, REVIEWED FOR CODE COMPLIANCE • Replace 42" guardrail and infill to comply with Approved: NI\J ] IBC multi-family code OTC: [ ] Permit#: r;up anal - COPa6 Address: )Cs-JQ 5�. i JLl cT Suite#: "7 O By: J Date: /-�7 —a I File Name: Fountains Deck Permit Plans REVISED.pptx 3/19/20 Fountains at Summerfield - Deck Building Plans 1 Typical Deck Construction and Size — 102 SF wick col. 114.5" 15 x 11.5 Imbedded 6x6 PT [� p E� 4x4 PT Posts A 2 x 8 PT blocking between joists attached with Three 16D 3-1/2"n HDG >< >< Ref: 2014 Oregon Structural 43" 15" 56.5" Specialty Code—Table 2304.9.1-29 2"x8" Joists 16" OC Blocking supports Simpson Rim joist attached to Tension Ties DTT2Z. Two lateral joists with DTT2Z brackets required for Three 16D 3-1/2"n HDG posts in this position. See Beam — 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty ^ Tension Ties—page 337 Code—Table of N 2304.9.1-29 House —Brick exterior 43" immimb Scale— 12"/increment V 3/19/20 Fountains at Summerfield - Deck Building Plans 2 Water Penetration Remediation — Cross Section Posts—4x4 PT Flashing 2" x 3" Resurfacing material low 3/4" exterior plywood decking U, 0 E o0 x Hardi-plank Fascia 9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by%" extension. Pre-paint before adding flashing 1/2" I w ood soffit plywood Scale— 1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 3 Guard Rail Post — Simpson Tension Ties Posts—4x4 PT ; ± r Simpson DDT2Z ittf, Attach to lateral joist with 8 SDS 1.5 screws di 41* 1/2" x 6" Machine Bolt DTT2Z supports 1800 lb. HDG with nuts and tension load. Meets IBC washers Code for multi-family deck co 'o guardrails. x N E Refer to attached Simpson catalog- Deck Tension Ties Lateral Joist page 337 Also refer to Simpson code- compliant Guardrail Post Connection bulletin T-C-GRDRLPST17 Scale — 1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 4 Typical Guardrail and Infill Section — 50" max. between posts Simpson Strong Drive A a 1 l I Wide Screw SDWS / - Railing 2 x 4 TKC 2 3/8" TL. Two per4", I Cap Rail —Trex beta/ end, three in mid span 1" x5.5" attached to q: Railing with exterior , adhesive. Zn Railing Support T 2x4TKC . oo Attached to 1— a ri Railing and Installation of Posts with v balasters and rails adhesive and 1 per mfg installation Simpson instructions. Strong Drive Wide Screw SDWS 4", - 2 3/8" TL. Railing 2 x 4 TKC Railing Infill DecKorator aluminum V _ 2.75" space balaster%" x 32". • • Spacing 3.75" DecKorator Scale 1" increments • lb CodeCompliance Research Report ! iiIiiiitiii ] CCRR-0161 3/19/20 Fountains at Summerfield - Deck Building Plans 5 of 5