Plans AN 11 CITY OF BUILDING DIVISION Building Plans for City of Tigard Building Permit Application Customer: The Fountains at Summerfield condominiums HOA 15685 SW 116th Ave., #105 Tigard, OR 97224 Contact - Paul Brock, 858-212-9105, pbrock987Pgmail.com Contractor: Jon Erickson, 503-730-9220 jon.evenjobs(Jgmail.com CCB 162397 Scope of Work- Repair Decks .,OFFICE CORN • Replace perimeter joists with PT CITY OF TIGARD< • Repair joist and soffit dry rot REVIEWEit CODE COMPLIANCE • Replace 42" guardrail and infill to comply with Approved: IBC multi-family code OTC: [ I Permit#: arA.) - C�f� Q �7 Address: )S'_ /O S w 11 tf C-1' Suite #: t'/.? By: -'-if Date: 1 '-, 7 -s24 File Name: Fountains Deck Permit Plans REVISED.pptx VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM REQUIRING THE CORRECTION 3/19/20 Fountains at Summerfield - Deck Building Plans OF ERRORS. OSSC 105.4 1 Typical Deck Construction and Size — 102 SF Brick Col. 114.5" 1Sx11.5 <� Imbedded 6x6 PT �I • --In � 4x4 PT Posts A 2 x 8 PT blocking between joists attached with Three 16D 3-1/2"n HDG >< >< Ref: 2014 Oregon Structural 43" 15" 56.5" Specialty Code—Table 2304.9.1-29 2"x8" Joists 16" OC Blocking supports Simpson Rim joist attached to Tension Ties DTT2Z. Two lateral joists with Q / DTT2Z brackets required for Three 16D 3-1/2"n HDG posts in this position. See Beam " 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty Tension Ties— page 337 Code—Table ai 2304.9.1-29 House — Brick exterior 43 17/ Scale 12"/increment V L�� 3/19/20 Fountains at Summerfield - Deck Building Plans 2 Water Penetration Remediation — Cross Section Posts —4x4 PT Flashing 2" x 3" Resurfacing material 3/4" exterior plywood decking 0 E it co N Hardi-plank Fascia 9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by%" extension. Pre-paint before adding flashing %" plywood soffit Scale — 1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 3 Guard Rail Post — Simpson Tension Ties Posts— 4x4 PT Simpson DDT2Z \\\\\\\\\\\\\\\\\\\\\\\\ Attach to lateral joist with ' 8 SDS 1.5" screws 1/2" x 6" Machine Bolt DTT2Z supports 1800 lb. HDG with nuts and tension load. Meets IBC washers Code for multi-family deck 00 .o guardrails. x N E Refer to attached Simpson catalog - Deck Tension Ties Lateral Joist page 337 \\ Also refer to Simpson code compliant Guardrail Post Connection bulletin T-C-GRDRLPST17 Scale — 1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 4 Typical Guardrail and Infill Section — 50" max. between posts Simpson Strong Drive Wide Screw SDWS 4", 2 3/8" TL. Two per Railing 2 x 4 TKC Cap Rail —Trex Oetd�� end, three in mid span 1" x 5.5" — attachedto 1 Railing with i IIIIIL ,ALAIMIL exterior , adhesive. in Railing Support Tr 2x4 TKC . ° a o Attached to i a Ni Railing and Installation of Tr Posts with balasters and rails adhesive and per mfg installation Simpson instructions. Strong Drive Wide Screw SDWS 4", 2 3/8" TL. Railing 2 x 4 TKC Railing Infill - DecKorator aluminum v _ 2.75" space balaster%" x 32". • • Spacing 3.75" DecKorator Scale 1" increments • • CodeCompliance i i i i i i Research Report iiiiiii CCRR-0161 3/19/20 Fountains at Summerfield - Deck Building Plans 5 of 5