Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (2)
Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND ,_ '^ BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). . GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. Delete Line � V v Txxx-XX 1i BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. u1 `MAXIMUM SPACING( P) =F= =1/2"PIPE SIZE C w m 2 g Add Line — — — — — SPRINKLER MODEL(TYP) MOST HYDRAULICALLY REMOTE HEADS =3/4"PIPE SIZE a m®'u HEAD SYMBOL(TYP) EXTERIOR WALL 7 ELEV=106' `-„W T / HEAD# • GPM PRESSURE REQ'D AT STREET �1-- =1"PIPE SIZE „ :D Add Tee ( I I \\/// CURRENT STATIC / 1 HEAD H.3 13 28.52 �I, =1-1/4"PIPE SIZE tv iv N i WATER PRESSURE / \1-1/4"AQUAPEX 2 HEAD H.9&H.6 26.06 43.3 n ce_ 2 Add Elbow ' r, STATIC: 55ps1 \TO SYSTEMa N Add Coupling I--I / s S TO HOT WATER HEATER I m ' 3 1"WATER METER • ELEV=1oa. ® - - - 8 LF SENJU Model RC-RES Residential Flat Concealed Pendent 558464 lr s I� W Pr a W / K=4.9, 162E,7/16"Orifice,Maximum Spacing 16'x16' ra!\ i a of=,Fu 3 Add Head -®--®--®- STANDARD LOSS PER NFPA 13D / F-�_ RC-RES-16 Sprinkler head demand: 13 gpm 7.04 `r^"�- p, (' :::::5:1F48NiIirii'll 1" 1 (3PSI LO55 FLOWING 26GPM) / uF-�_ • ' �' r �'I'-`" �m/ 1-1/4"FULL PORT 9e.op <Delete Head - - BALL VALVE - - LF SEN]U Model RC-RE5205 Residential Flat Concealed Pendent SS6464 `goEo3�- - 1 K=4.9 205F° 7/16"Orifice,Maximum Spadng 14'x14' C n4mp1 , CSC 15 2.�0wMove Head / RGRES-t4-205 Sprinkler head demand: 13 gpm 7.04 •1• 1 O (� I'��4 m�o4,2st,,o Note:All revisions must be reviewed by Uponor ELEV=100' ELEV=100' CITY OF TIGARD ci°<Pm FEozo3 < Table FDste k O BUILDING DI',ISifr.. =;sB3 g;� 0_ › Multipurpose Fire Safety Systems 1"Mtl ER ._ l� ly l"� 8 I,Rs4o 5�G The Uponor Residential i en ial Fire Safety System is a residential fire protections 35'OF 100'OF !/ fFy W'm o m ,._y B >a` system installed in oombinabon with the cold side of the domestic potable 1"COPPER-K 1-1/2"AQUAPEX ',l �,. S me o < a water system. Only licensed contractors trained by Uponor can install this •^�^ �t O `` rl 6 5 d t < '-„ system. 7— c .7 €'' V _ S'6F2O6P6'1:6 1 WATER SERVICE DETAIL °a ` ,°,q",` w What to do it Changes are Required L(. ���� ���� Q I' � H £PJrc O r)C}V If any Features or obstructions reouire the addltlon or deletion of sprinkler -O 1 w"'<n a P °=z '_m LL heads,or significant relocation of sprinkler heads,contact the Uponor Design °u =u m.' C. l �100 }l I ! I �� % PFUP = Vl� Department to determine if observed changes require a redesign NTS sa • Iz°z $ zu�'90 l'' �� BBB.594JR°. O P Pmd.0 II5�z Wel ( ) r- n J.W<m< f^� o00 Pa o N V^ 0 BPPQ }zm_o~�o 1 la I, ... am Yam =^a I'i G V 1 'W °2107zz< 9: ,—I a� PPoo� T ___ ll 4 to -m w=alc am ,,,_ • I I. Forth � I' it 1 \ LOW - -� _._ _. in I 'u (BEL ry I A� II I V Y 4 /� ` . — ROOF 2, •Ilk 11 s.1 MAIN SHUTOFF Itern bycertify that thisplan,s etlfication, o-F- -- —di-- --- f "4 \� 0 ~ L < '- report wacer prepared bycon or pndfic my �-I V T,12 b VALVE LOCATION ce NP a, ir ^ I Q- Q / Y PE% direct supervision and MatI am NICET FL- it ' I i IhC-RES-ts FIRemn_E �� ;74 11 / FORK °' ITO SYSTEM Uo�46'18 a % I ¢ N V •rZ r T O O ti M }9. Brent Kotula Date: 2020 we I; RGRES--' - 1 I �t Z L I l _ NICEr Certification Ills e9 H 1 11I/���7y/ t6 _T a.) / Water-Based Systems Layout-Level N c I! , / L I Li I - C C �+ Z] 1 11 Certification Expires:lone 1,2023 Z. 1 I( ' � Q c 2 a�i ¢a I.`ref IUI2 -Ij \ j I1 U 1 0 f� \ `' 1 / I (_ `IfF.3 F.2� 1 -� j T.24- R stets Q 3 m ,FA '� ) / I M �5 H.5RC- -I I 1"AQUAPEX INTERLEVEL ' ' T 27 y m m m o �q� :yl H.5 7 CONNETONS FROM LOWER — T.28 r - 1 w ry JI f^^Pd' _ IT- / I \ • ..1! / 'l FIDOR TO MIDDLE FLOOR ` — ._ �. 5,.M 3 V m w T. — // N •• • = F� ' RES- 05—" '�� *// tF9 0 ..w o Ire f it _. - - F -11 - - - // u E. \ 1 aQUAPEx INTERLEVEL L _ -� .. // ` ` . w a a G=0 5 O1 jj, _✓\_. — �i' CONNECTIONS FROM MIDDLES-- — L - _..L ' a O kFp. 7 alf � I / T. .I; D O D J S m w 1 j/ FLOOR TO UPPER FL000. e - D V 8 6 u N Z O I- __ _ _ `l f� v�Di zo 1 ` RH O I // / ,1 F.7 T.22 T.25 I /// �� �� OCLt I T 23 �,`., BELOW 1 1 / I— 1 _ ✓ -_ 6LQOR ABBE 1 i6 r'O'rth Q o' I i :/-... 1 5 aoli t .8 L Q l o NW.'��6 T.. 2 mows. C9mi 1 I. �, �I T3 Y '^ Bedroom aid I /.Try 2 S=on N N'V 1 I ""- In Wmm :! O E�,6 • 1� LOWER FLOOR C H F � tI. _ i I�— 1/'' — i - SHEET DESCRIPTION -- ALL FLOORS I $ ' I e r.lt SHEET NUMBER s - D_5 15 UPPER FLOOR 1z� MIDDLE FLOOR uuo : OJ F100 II C-3- 10� 1/4N = 11-OR 1/4 = 1 —0 © UPONOR - CONFIDENTIAL P Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND `_ Er BLUE LINES .FEED TO FIXTURES(BATH,SHOWER,ETC.). O E o Delete Line T// XXX-XX GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. '� s L— BLACK LINES=•SPRINKLER HEAD TO SPRINKLER HEAD. g MAXIMUM SPACING(TYP) —,— j n =1/2"PIPE SIZE Add Line — — aJ SPRINKLER MODEL(TYP) q E£a T HEAD SYMBOL DYP) f —f— =3/4"PIPE SIZE a a�u Add Tee I =1= =1"PIPE SIZE • • O UGH =1-1/4"PIPE SIZE T ui.A,nz Add Elbow id Q >rI'D, n H M mu, ul Add Coupling 7.N m 3 i . .' , -- PAL; Add Head -®--®--®- m o -= d Ewtl'a Delete Head -l%)- 91 'Ogg o Jr ice. p£ego0,Fp�3 Move Head -- u EXt;°.RF'o2..coz l 4-o2E,42.Fg_m°z Note:All revisions must be reviewed by Uponor pppp E Og i LL 2 E n i., Table F0112-1 dp-co�Op2urS w» Multipurpose Fire Safety Systems zE clFili'="2tai The Uponor Residential Fire Safety System is a residential fire protectcns g=o z e'a p o 0 i v g watersystem sinstalled in combination with the cold side of the domestic potable W mm„>- . zL system. Only licensed contractors trained by Uponor can Install this qQ o D e t a p'A O system. 2-.1,62 z`4 EE<gd What todoif Changes are Required U P.ed H1,`.q'«ya § yp fy i0 U IInds any features ornt obstructions of uire thesprinkler addition ont ct an of Uponor Des t' <yp 72cYoemE heads,or nt to<termincif relocation observed heads,contact the Uponor Design G '-coo 'p� �Er o_2 Department determine if observed changes require a redesign iErmor Ngp mm (888.594.7726). E;43,E. "F E6EgQ a m z ipa<rokN %12IT ..:I a'b Sm OY .4 .Jm> G1�>6j��" V , I P 'w "2"Jz7,0 c Zrlc UOa�.�vi-'' r�«r�<V 6S Naocs ; � _ f - __ VC 1 I I I here by certify that this plan,specification, EE ', {I I or report was prepared by me or under my I t direct supervision and that I am NICET Zr- 11 1 1 'RE$. 6 1 { • Brent Kotula Dare: 2020 m Ili 4 VA MAIN SHUTOFF } IM1 T 12-\ I, N[CEf Certification No.113889 1 � ��'111 RC•RES1 VALVE LOCATION fl t -'r'-- \ Water-Based Systems Layout-Level N ,. H p j _ 1 Certification Ecpires:tune 1,2023 ui 4 1{'AquaPIX T '1 I� FIREPLACE TO SYSTEM 1 1U __ 1 6. i j� — T114, I� �' I \ 1 Co.) RC-RE1S-16 a II 1 Eli ' \ T � I F.2- F.3 ` 1 R,' A T. ji - f{ _ ..w oa aS -RGRES I , • _, CONNECTIONS FROM MIDDLES / ` — — p �1 e 2"�' r r E. rn ._' 1 _ P'AQUAPEX INTERLEVEL C-` .. 1 T. W u Ci O 0 0 u F. {`7I i ` `._,. "—� / 1'AQUAPEX INTERLEVEL ' i p w U G o` I ` FLOOR TO UPPER FLOOR / ,-CONNECTIONS FROM LOWER - -� — — _ o1)��� r rF' i jj FLOOR TO MIDDLE FLOOR.20 fH O g 4 M O a BELOW I —� 0 1 Ill I / Y"�T 23 I I j - TI I .25 4 T7 i Q co O Y a " ' - .1 - � I' " U j Q Q zzEm2 m o - I a u, m.a W H.9 I ` 1 I . 6. _ �=m� I o I o z T T.3 1. Cr) Q m m a 0 2m2 RCRES1fr " � ' i aJ. � c3wggj m —__ l I ' LOWER FLOOR MIRROR A L - - T T --- t __....-1 / - SHEET DESCRIPTION 1 L__ 1 p I - �.�� 1 �_.,.__ � � � 1�1�I ALL FLOORS-MIRROR FU 1/4" = 11-0" SHEET NUMBER 51 3 UPPER FLOOR - MIRROR z MIDDLE FLOOR - MIRROR ,-- 5 t 1313 (-- 101 1/411 = 11_011 �101 1/41I = 11—Olt © UPONOR - CONFIDENTIAL F101 ' •e. AquaSAFE GENERAL NOTES: Senju RC-RES:Open Web Truss/TlI Construction Insulation Recommendations see General Notes 8.2.5.7 for Architectural N TIVI In areas subject to freezing,care should be taken in unheated sums spaces -° ProPEX LF Bras Flre to cover Uponor aqua Plines tubing completely with Insulation. Insulation Feature Requirements Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor - - - % y a 1. THIS SYSTEM IS DESIGNED AS PER NEPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Blocking Maybe rFire Sprinkler Adapter Document"Uponor AquaSAFE Attic Insulation Guidlits package for attic or O i 0 SECTION 3.3.11.3. Required.]f Cs _ Y"Push-on Nut installation guidelines(Provided In Contractors Documents or online Blocking Is Used, , r / 1 at www.Uponorpro,com). ¢..i 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON Use The 2 Top t/a Min. THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND Screw Holes. i -c 1I t "Mm planter Box Window,Bay Window or Similar Feature. Cs g p UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT'OF THE LAW. T�-� Bottum olMounting Extreme Temperature Installations If no addltlna Floor area is created No Additional Sprinkler is Required. ®'O placket w Face°rTruss AquaSAFE Residential Fire Safety systems are often installed in attics or a m w< 3. THE DESIGN OF THIS SYSTEM 15 DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adapter - I other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0°or less L, w n V RESPONSIBILIT/OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Mounting Bracket the recommended extreme weather installation instructions to isolate and / 1 x m a i PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD, DEVIATIONS FROM THE DESIGN MAY CAUSE THE protect system mmponenls from extreme LemDeraturez. Because this RCAESt6 u i A w i SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE •¢ �• system also delivers domestic cold water directly to plumbing fixtures, 9'-0"or less NV ry z s SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-910 x]1/2" } Opener highly recommends that you protect the tubing with adequate / , m IY r V c Full Course D� t Insulation In warm weather areas to minimize heating of the cold water c N=d o; 9. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread Skews 11 11� supply c a c r�S NFPA 130 2016 EDITION. In Batton Holes - 0. IR 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERM]:I EU TO USE ANTI-FREEZE. - \.- \ Installation methods include,but are not limited to: wo m W�,0=W - • Tendng over the fire sprinkler Piping. O n f w 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Lead-Ergs Ma£ -,. r" rx I t y • Additional layers of batt Insulation. If additional floor area is created.Cannot exceed 18 h,be more than 2'-0" < o DAMAGED MUST BE REPLACED. Concealed Senju \ '- Concealed Flat • Increased depth of blown-in insulation. deep,more than 9'-0"wile and be with in the coverage area of the iW j Sprinkler Head Cover Mate sprinkler.Na AddMonal Sprinkler Is Required. PF i< i F E S x 7. WATER SHUT OFF VALVE IS NOT PERMII I ED THAT ISOLATES THE SPRINKLER SYSTEM- Caution: If you will be installing spray foam Insulation,make sure to pol„') `B tI D E 2 d Senju RC-RES:Traditional Wood Framing Construction protect all components donne BpplimOon.Consult with the spray foam NFPA 33D Table 7.5.5.3 Distances From U ;°Ooze's B. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER manufacturer to ensure compatibility with all products before apNIabon, pp z5v,z.Fo,gyaq o 9. AT THE MAIN SHUT OFF VALVE,A TAG ORA SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Heat Sources F�Soo.OzSl-,°Irmo Consultation with local building officials is encouraged to ensure compliance R.4 B m '=0 I WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND with foal building codes. z on o 6 Fo U z o <a PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR PrdPIX LP Brass Flre FIreS rinkler Adapter Ordinary Intermediate -000f°1s s _ AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH PS WATER SOFTENERS, Sprinkler Adapter Tee p Heat Source Temp, Temp. oos"'rm f-kz FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM /d Push-on Nut 135°-170" I75^-2256 o r o 9 m U< E s .o zzopp ..o WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE • r-I Bending PEjI Tubing Side of Fireplace 36° 12° w'pi coca o c r h THIS SEW. 1 1 1 ' / 1 t/y Min. The minimum bend radius of Uponor PE(tubing in any direction is six limes paCe 60" 36° W o°10 m q o N b.a b.s 3 p°. I-,L-1� Front of Hre _ 1 Max. the outside diameter(6 x OD). S"'s�«t:n✓ £I<m°I 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPIX®"UNLESS NOTED, aanam of Reaming Bend supports are available for 3/8",1/2",3/4"and 1°Uponor AquaPEX Wood Burning Stove 42" 12' ti z_ z Mounting BracketFre Sarin der „ Bracket to=are°r Truss tubing to facilitate 90-degree rigid bends. Kitchen Ralge.. 18" 9" C w S yF g R u M£ie i o 11. UPoNOR"AquaPIX"TUBING TO BE SUPPORTED PER NFPA 130 AND MANUFACTURER'S RECOMMENDATIONS, ���/ 18" 9" V a.,n w l.°"3 m m W, r a Wall car ao o>•St 6u �'y 12.MINIMUM SPACING BETWEEN SPRINKLERS IS B'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-A30 x 1 1/Z° �, • Recommended Tubing Length Between Fittings Hot Air Flues 18" 9° sNi a e o_o z- m m s BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Course - - } Uninsulatetl Heat Duch 18" g° O a F geg`•a P 8 r. Fl i4 RESTRICTIVE SPACING LIMITATIONS. 1 I Fitting Size Minimum Tubing Length Uninsulated Hot Water Pipes 12" 6' i oat y O a G o In Screws 'i Op '- In Top Holes ■ i 3/B"ProPEX Fitting 2" Side of Hot Sr Diffuser 24° 12" z<m a 03 cam 2 S O C,o 13.SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUETO LIGHT FIXTURES OR OTHER CEILING MOUNTED OBSTRUCTIONS. _ \ 1/2"ProPIX Fitting 2 1/2° Front of Hot Air Diffusor 36" 18" 3 �'m m�' > w<�'< 3/4'ProPEX Fitting 31/2° Hot Water Heater 6" 3° �goivoo�"a„oo�°o I 14.THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE Leatl-Free secs _ ]"proPE%Fitting 4 1/2" Furnace 6" 3° LL u�e o o- m z F u SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. Concealer Senju \ Concealed Flat °o m z u S E D 15.THIS SUGGESTED LAYOUT 15 BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN Sprinkler Head Cover Plate 11/4"ProPIX Fitting 5 U2" SOW-250W Ugh[Fixture 6° 3" g•u � _o E'm d CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS 2E0W-499W Light Fixture 12" 6° D E I: o ok s m z S "'>G°w3z -cacao- a THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. \ Ft NF oik$§San < w Exposed Installation Requirements. \ 2 16. NFPA 13D B.2.5',OBSTRUCTIONS TO RESIDENTIAL SPRINKI FRSI • 8.2.5.6E SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTIONUponor AyuaPIXr"'tubing(white)and ProPEXn•EP Fittings and ProPIXTM AREA OF A SPRINKLER AS LONG AS Brass Fittings are approved for exposed installation where the following THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FP PER SPRINKLER, conditions are met(UL 1821 Approved) • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED PS FOLLOWS: (1)WHERE NO ADDITIONAL FLOOR AREA 15 CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Hoist Ceiling Assemblies. r, n J--'.,5 I here by certify that this plan,specification, o. ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are M dimensional lumber,engineered wood,wood]-joist or open �' m m or report was prepared by me or under my (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists, m direct supervision and that 1 am NICET y SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). ❑ Certifie. 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. .. (a)THE FLOOR AREA SHALL NOT BE EXCEED T FT'( N F 4. Joists can be exposed alter Installation. \ ji \ a (h)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 5. Metal pipe hangers spaced at maximum 24 Inches(610 mm)on center 1.55" 1.66" THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED - .� Brent Kotula Dale: 020 ALONG THE PriFINISHED FLGRE are used. 3„ -3„ NICET Certification Na.1138E9 o (c)THE FLOOR SHALL NOT BE GREATER THAN AFT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation 2 -4 Hanger 1" Hanger PLANE OF THE PRIMARY WALL temperature rating of 155°F(68°C). Water-Based Systems Layout-Level IV (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER Certification Expires:June 1,2023 '' SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Metal Tubing Support. Tubing Support Spacing: x (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE 1. Metal tubing supports designed for plastic tubing shall be used. (Anchor Aqua PIX Tubing Securely Enough to Support the Tubing,Yet Relaxed ARCHITECTURAL FEATURE. Enough to Allow the Tubing to Expand and Contract) 2. Do not use supports that will damage the tubing,inspect metal supports for sharp edges. 1. Along Horizontal Runs,Install Supports Every 32',If Horizontal Runs are • 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. 3. Do not rigidly anchor Uponor Aqu3PIXrt tubing with supports.Allow 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 enough tubing for freedom of movement expand and contract. Contlnuousty Supported,Place Tubing Supports at Slx-Foot Intervals. 2. Along Vertical Runs,Install Supports Every Four to Eve Feet,at Each ` • THROUGH SP N Kl E Floor and at a Mid-story Guide. W 2 •• 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMSOTH OF 55 F 1 LO AND LESS - - z • MEET SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT m ' Y MEET ALL OF AE FOLLOWING THSPACE CDOESTIONS: heIn-line Flow Test e.S m c (1)TH E AREA OF THE SPACE DOES NOT EXCEED 24 FP NC RV). The In-line Raw Test can he constructed on site. R e P001-a flow test to b c (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE Standard Riser Assembly ensure proper system operation and flow(see Figure F001-8). O :. MATERIALS AS DEFINED IN REQUIRED 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. In a safety purpose system a single control valve controls both domestic and g m m 0 A-1 8.3.4• SPRINKLERS SHALL NOT BE IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND fire safety needs. p!`.mom,.v SIMILAR STRUCTURES Uponor AquaPEX 3 U w Ti m�+ m • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN ATECS WITH OR WITHOUT STORAGE,PENTHOUSE Tubing w .. n w m EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED IXCLELEVAT TO �/ CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING T SPACES,ELEVATOR SHAFTS, Y i z b CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING z v; PURPOSES. E w J O u • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR - Ce 8.3.5 1.2 ---�� LLJ 0.- F,,,`6 • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING -- -- 6l-g S t �o UNIT,ND SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE, Y z 0~O w N G p` • 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE O O O x 0 x w w F- DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE Male Threaded Coupling Prone(Fre 1 1 u u u a°.m m p z INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED Sprinkler Adapter Ce 0 c EQUIPMENT FROM THE OCCUPIED SPACE. Lim w U • EENTRANCES/EXITS SCEEXSS SHALL NOT REQUIRED LLI GI NIT UNHEATED FIGURE OFS,THE BUILDING AT L •-To Hot Water Heater Male Threaded Coupling t"Ball Valve rc x5,37 LONG 3ASTTHE QUI RED F UNIT HAS ANOTHER MEANS OF EGRESS. 2 • C SPRINKLERS SHALL NDT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING Female Threaded etl Q c CONDITIONS: fi Tee with Water LL w (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED s tt "i Pressure Gauge ClO 0�, E 100 FP(2.831W). cfo Sprinkler Orifice (Optional) o x O rn (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS x aIli o AT THE LOWER CEILING ELEVATION. ry Uponor Warning Signs < SQ mxzi°e,n O. (3)'THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE a Flow Test ?o 2:2 C N m TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. i To ensure the system provides enough water for proper fire sprinkler = Z . c z m.-•Ti-• m 'n performance,you should conduct a flow verification test. (4)SKYLIGHTS NOT EXCEEDING 32 FT,(2.9]Mu)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. 6 t w • 8.3.B SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS o Note: The NEPA 13D Installation Standard does not require flow UI j r mm-w-w o a m m$=LL m ACCESSED(REGARDLESS OF SIZE)UTD LOCATED ON EXTERIOR T DOES EXTERIOR BRDOORS OR UNPROTECTED TEIDORS,OR c n verification. I-"I Y z w a G w m ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE ODORS OR UNPROTECTED u ¢ G Main Flre Sprinkler Ce �"' S u c P< H PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. c` r Shut-off Valve Before performing a Flow verification test,confirm the water pressures by o y z G o ti N 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING z available watercontacUng thees r d Sewer mar matc hes rtme orefused ourin the systeocal city. m designsure e >O V,'6 z at EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.B. pressurepress 18. INSULATION GUIDE LINES PER NFPA 13D. - Note: The sprinkler plan Indicates the most hydraulically remote sprinkler SHEET DESCRIPTION c • 9.1.1*WET PIPE SYSTEMS IN AREAS ABOVE 411 -°F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE 2 (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40°F,INCLUDING AREAS PROPERLY a your local code. ,„ INSULATED TO MAINTAIN 40°F. ^ •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: It is a good idea to notify the fire Inspector at least 24 hours prior to in 'a COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing a flow verification test.This may speed up the inspection q, GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.L1(A)THROUGH FIGURE A.9.1,1(F) process and eliminate the need to repeat the test for the inspector. SHEET NUMBER o SHOWS SEVERAL ION METHODS THAT CAN O CONSIDERED.RACTRANTHESE O ARE FORS COMMENDED PURPOSES ONLY. Note: See"AquaSAFE Flaw Test Instruction Sheet"(Provided In FO o i CONSULTATION SWITH THE GENERAL SL CONTRACTOR AND/OR 40 F BE RECOMMENDED TO ENSURE Contractors Documents package or online at www.Uponorpro.com)for 01 PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40°F WILL BE MAINTAINED, - more information on Flow Test Setup,Assembly,Performing the Test and Troubleshooting. If there are any questions please contact Uponor. < © UPONOR - CONFIDENTIAL