Plans Building Plans for City of Tigard Building Permit Application Customer: The Fountains at Summerfield condominiums HOA 15685 SW 116th Ave., #105 Tigard, OR 97224 Contact - Paul Brock, 858-212-9105, pbrock987@gmail.com Contractor: Jon Erickson, 503-730-9220 jon.eveniobs@gmail.com CCB 162397 Scope of Work— Repair Decks • Replace perimeter joists with PT "OFFICE CioPN. • Repair joist and soffit dry rot ' CITY OF TIGAR FOR CODE COMPLIANCE • Replace 42" guardrail and infill to comply with Approved: i IBC multi-family code OTC: t I Permit# : c 1 i - 0 J 16 Address: 1SS CS' 3\,a J Jy Suite#; a,r gy; Data File Name: Fountains Deck Permit Plans REVISED.pptx VALIDITY OF I-,L.. THE ISSUANCE OF A PEP. BASED ON CONSTRUE 110k, DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM 3/19/20 Fountains at Summerfield - Deck Building Plans REQUIRING THE CORRECTION OF ERRORS. OSSC 105.4 Typical Deck Construction and Size — 102 SF < > Brick Col 114.5" 15x11,5 Imbedded 6x6 PT A L'J nl F-1 4x4 PT Posts - 2 x 8 PT blocking between joists attached with Three 16D 3-1/2"n HDG 43" >< 15" >< Ref: 2014 Oregon Structural 56.5" Specialty Code—Table 2304.9.1-29 2"x8" Joists 16" OC Blocking supports Simpson Rim joist attached to Tension Ties DTT2Z. Two lateral joists with C Three 16D 3-1/2"n HDG DTT2Z brackets required for posts in this position. See Beam — 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty Ln Tension Ties —page 337 Code—Table 2304.9.1-29 House— Brick exterior 43" Scale— 12"/increment V Lammaym 3/19/20 Fountains at Summerfield - Deck Building Plans 2 Water Penetration Remediation — Cross Section Posts—4x4 PT Flashing 2" x 3" Resurfacing material 3/4" exterior plywood decking Y N 0 1c C co N Hardi-plank Fascia 9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by 3/4" extension. Pre-paint before adding flashing 1/2" plywood soffit Scale — 1" increment inNoimm 3/19/20 Fountains at Summerfield - Deck Building Plans 3 • • Jtaio. Guard Rail Post — Simpson Tension Ties Posts—4x4 PT Simpson DDT2Z \� Attach to lateral joist with 8 SDS 1.5 screws %" x 6" Machne Bolt DTT2Z supports 1800 lb. HDG with nuts and tension load. Meets IBC washers Code for multi-family deck Ln 00 .o guardrails. x E Refer to attached Simpson catalog- Deck Tension Ties Lateral Joist page 337 Also refer to Simpson code- compliant Guardrail Post Connection bulletin T-C-G RDRLPST17 Scale— 1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 4 Typical Guardrail and Infill Section — 50" max. between posts Simpson Strong Drive ~ Wide Screw SDWS 4", 2 3/8" TL. Two per Railing 2 x 4 TKC Cap Rail —Trex �eta7, end, three in mid span 1" x5.5" attached to Railing with exterior adhesive. in N` Railing Support a [ 2x4TKC . a 00 Attached to 1 a a Railing •and X Installation of Posts with balasters and rails adhesive and per mfg installation Simpson instructions. Strong Drive Wide Screw SDWS 4", Railing 2 x 4 TKC Railing Infill 2 3/8 TL. DecKorator aluminum `/ _ 2.75 space 3 „ balaster x 32". Spacing 3.75" DecKorator Scale 1" increments e i CodeCompliance Research Report imiiiiiiiii CCRR-0161 3/19/20 Fountains at Summerfield - Deck Building Plans 5 of 5