Loading...
Plans RECEIVED JAN 1 1 2021 CITY OF TIGARD BUILDING DIVISION Building Plans for City of Tigard Building Permit Application Customer: The Fountains at Summerfield condominiums HOA 15685 SW 116th Ave., #105 Tigard, OR 97224 Contact - Paul Brock, 858-212-9105, pbrock987@gmail.com Contractor: Jon Erickson, 503-730-9220 jon.evenjobs@gmail.com CCB 162397 Scope of Work—Repair Decks • Replace perimeter joists with PT O f ICE COP • Repair joist and soffit dry rot • Replace 42" guardrail and infill to comply with CITY OF TIGARD. FOR CODE COMPLIANCE IBC multi-family code Approved: ' OTC: : { j Permit ft i at)a J -On ) 13 Address: 1.C-�(.c - Zus t j(4 e-t Suite#: 13 File Name: Fountains Deck Permit Plans REVISED.pptx By Dare: • VALIDITY OF PERM€ THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVENT 3/19/20 Fountains at Summerfield - Deck Building Plans THE CODE OFFICIAL FROM 1 REQUIRING THE CORRECTION OF ERRORS.OSSC 105.4 Typical Deck Construction and Size — 102 SF < > Brick Col. 114.5" 15ic115 <` Imbedded 6x6 PT 4x4 PT Posts A 2 x 8 PT blocking between joists attached with Three 16D 3-1/2"n HDG >4( >.< Ref: 2014 Oregon Structural 43" 15" 56.5" Specialty Code —Table 2304.9.1-29 Blocking supports Simpson Rim joist attached to 2"x8" Joists 16" OC Tension Ties DTT2Z. Two lateral joists with / DTT2Z brackets required for Three 16D 3-1/2"n HDG �> posts in this position. See Beam — 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty Tension Ties—page 337 Code—Table of N 2304.9.1-29 House—Brick exterior 43" > Scale— 12"/increment V I LLB 3/19/20 Fountains at Summerfield - Deck Building Plans 2 Water Penetration Remediation — Cross Section Posts—4x4 PT Flashing 2" x 3" Resurfacing material 3/4" exterior plywood decking N O C 00 X N Hardi-plank Fascia 9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by 3/" extension. Pre-paint before adding flashing %:" plywood soffit Scale — 1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 3 Guard Rail Post — Simpson Tension Ties Posts—4x4 PT f Simpson DDT2Z 111 Attach to lateral joist with 8 SDS 1.5" screws %" x 6" Machine Bolt DTT2Z supports 1800 lb. HDG with nuts and *-- tension load. Meets IBC washers Code for multi-family deck guardrails. E Refer to attached Simpson catalog- Deck Tension Ties Lateral Joist page 337 \\ \\\\\`\\` Also refer to Simpson code- compliant Guardrail Post Connection bulletin T-C-GRDRLPST17 Scale— 1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 4 Typical Guardrail and Infill Section — 50" max. between posts Simpson Strong Drive A Wide Screw SDWS 4", Railing 2x4TKC \ 2 3/8" TL. Two per Cap Rail Trex \ / Oet end, three in mid span 1" x 5.5„ attached to Railing with ' exterior adhesive. 11111111)11111111111 in I N Railing Support 1 ryi v 2x4 TKC . o a 0o Attached to �— a Railing and X Installation of .zrPosts with v balasters and rails adhesive and per mfg installation Simpson instructions. Strong Drive Wide Screw SDWS 4", 2 3/8" TL. Railing 2 x 4 TKC Railing Infill - DecKorator aluminum V _ 2.75" space balaster%" x 32". • Spacing 3.75" DecKorator Scale 1" increments • • CodeCompliance iiitiiiiiiiii Research Report CCRR-0161 3/19/20 Fountains at Summerfield - Deck Building Plans 5 of 5