Loading...
Plans RECEIVED JAN 11 20'1 CITY OF T IGAHu BUILDING DIVISION Building Plans for City of Tigard Building Permit Application Customer: The Fountains at Summerfield condominiums HOA 15685 SW 116th Ave., #105 Tigard, OR 97224 Contact - Paul Brock, 858-212-9105, pbrock987(a)gmail.com Contractor: Jon Erickson, 503-730-9220 jon.eveniobsPgmail.com CCB 162397 OFFICE COPY Scope of Work— Repair Decks CITY OF TIGARD., • Replace perimeter joists with PT FOR CODE COMPLIANCE • Repair joist and soffit dry rot Approved: I • Replace 42" guardrail and infill to comply with ETC' l IBC multi-family code Permit#: Ac J� Address: h Sw / /'7' <-1` Suite#: 4 - Data 1 -c�t' ) ) File Name: Fountains Deck Permit Plans REVISED.pptx VALIDITY OF PLF::... "r THE ISSUANCE OFA PERM! BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS. OSSC 105.4 3/19/20 Fountains at Summerfield - Deck Building Plans 1 Typical Deck Construction and Size — 102 SF Krick Col. 114.5" 15xii.5 t` Imbedded 6x6 PT n <� 4x4 PT Posts A LL 2 x 8 PT blocking between joists attached with Three 16D 3-1/2"n HDG 43" '< 15" '< Ref: 2014 Oregon Structural 56.5" Specialty Code—Table 2304.9.1-29 2"x8" Joists 16" OC Blocking supports Simpson Rim joist attached to C Tension Ties DTT2Z. Two lateral joists with / DTT2Z brackets required for Three 16D 3-1/2"n HDG posts in this position. See Beam 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty ^ Tension Ties —page 337 Code—Table o; N 2304.9.1-29 House—Brick exterior 43" Scale— 12"/increment V I-L L—`� 3/19/20 Fountains at Summerfield - Deck Building Plans 2 Water Penetration Remediation — Cross Section Posts—4x4 PT Flashing 2" x 3" Resurfacing material 3/4" exterior plywood decking Y U, O C co k fV Hardi-plank Fascia 9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by %" extension. Pre-paint before adding flashing %" plywood soffit Scale— 1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 3 . Guard Rail Post — Simpson Tension Ties Posts—4x4 PT ..�� Simpson DDT2Z \\\\\\\\\\\\\\\\\\\\\\\ Attach to lateral joist with ' - 8 SDS 1.5" screws %" x 6" Machine Bolt HDG with nuts and DTT2Z supports 1800 lb. washers tension load. Meets IBC Code for multi-family deck °x° ° guardrails. ^� E Refer to attached Simpson catalog - Deck Tension Ties Lateral Joist page 337 Also refer to Simpson code- compliant Guardrail Post Connection bulletin T-C-GRDRLPST17 Scale — 1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 4 Typical Guardrail and Infill Section — 50" max. between posts \ Simpson Strong Drive Wide Screw SDWS 4", Railing 2 x 4 TKC 2 3/8" TL. Two per Cap Rail—Trex �' Detat7 end, three in mid span 1„ x 5.5„ attached to Railing with exterior adhesive. m Railing Support N v 2x4TKC . c) o ! Attached to 1— v Railing and X 1 Installation of Posts with v 1 balasters and rails adhesive and . per mfg installation Simpson instructions. Strong Drive Wide Screw SDWS 4", 2 3/8" TL. Railing 2 x 4 TKC Railing Infill - DecKorator aluminum 1/ 2.75" space balaster%" x 32". • 0 Spacing 3.75" DecKorator Scale 1" increments • • CodeCompliance l iiiiiii i i i i i Research Report CCRR-0161 3/19/20 Fountains at Summerfield - Deck Building Plans 5 of 5