Loading...
Plans RECEIVED JAN 1 t 1�i21 CITY OF-TIGARD BUILDING DIVISION Building Plans for City of Tigard Building Permit Application Customer: The Fountains at Summerfield condominiums HOA 15685 SW 116th Ave., #105 Tigard, OR 97224 Contact - Paul Brock, 858-212-9105, pbrock987@gmail.com Contractor: Jon Erickson, 503-730-9220 jon.evenjobs@gmail.com CCB 162397 Scope of Work— Repair Decks • Replace perimeter joists with PT • Repair joist and soffit dry rot OFFICE COPY • Replace 42" guardrail and infill to comply with CITY OF TIGARD., IBC multi family code REVIEWED FOR CODE COMPLIANCE Approved:\[`f OTC: [ ] Permit#: 4D-Oa 1 ^ OC O ZO Address: ]t5 S (s 1MI 1`1 File Name: Fountains Deck Permit Plans REVISED.pptx Suite#: 3 6 By: - Date: 1 -a6' �) VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM 3/19/20 REQUIRING THE CORRECTION Fountains at Summerfield - Deck Building Plans 1 OF ERRORS. OSSC 105.4 • Typical Deck Construction and Size — 102 SF Brick Cc t 114.5" 15x11,5 Imbedded 6x6 PT �Qn < — 4x4 PT Posts 2 x 8 PT blocking between _ joists attached with Three 16D 3-1/2"n HDG 1H< Ref: 2014 Oregon Structural 43" 15" 56.5" Specialty Code—Table 2304.9.1-29 Blocking supports Simpson Rim joist attached to C 2"x8" Joists 16" OC Tension Ties DTT2Z. Two lateral joists with / DTT2Z brackets required for Three 16D 3-1/2"n HDG posts in this position. See Beam 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty in Tension Ties— page 337 Code—Table o; 2304.9.1-29 House — Brick exterior 43" ' Scale— 12"/increment V I -- 3/19/20 Fountains at Summerfield - Deck Building Plans 2 Water Penetration Remediation — Cross Section Posts—4x4 PT Flashing 2" x 3" Resurfacing material 3/4" exterior plywood decking 0 E co Hardi-plank Fascia 9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by%" extension. Pre-paint before adding flashing Y:" plywood soffit Scale— 1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 3 • Guard Rail Post — Simpson Tension Ties Posts—4x4 PT Simpson DDT2Z \ Attach to lateral joist with 8 SDS 1.5" screws %" x 6" Machine Bolt HDG with nuts and •. DTT2Z supports 1800 lb. washers tension load. Meets IBC Code for multi-family deck w •o x guardrails. `„ E Refer to attached Simpson CE catalog- Deck Tension Ties Lateral Joist page 337 \\\\\\\\\\\\\\\\\\\\\\\`, Also refer to Simpson code compliant Guardrail Post Connection bulletin T-C-GRDRLPST17 Scale— 1" increment 3/19/20 Fountains at Summerfield - Deck Building Plans 4 Typical Guardrail and Infill Section — 50" max. between posts A Simpson Strong Drive Wide Screw SDWS 4", Railing 2 x 4 TKC 2 3/8" TL. Two per Cap Rail—Trex \, oetd7/ end, three in mid span 1" x 5.5" attached to Railing with exterior adhesive. in m Railing Support N 11111111111 2x4 TKC . a o Attached to o a Railing and X Installation of Posts with .:r balasters and rails adhesive and per mfg installation Simpson instructions. Strong Drive Wide Screw SDWS 4", 2 3/8" TL. Railing 2 x 4 TKC Railing Infill - DecKorator aluminum 1/ 2.75" space balaster%" x 32". • II Spacing 3.75" DecKorator Scale 1" increments • IP CodeCompliance Research Report liiiiiiiitiil P CCRR-0161 3/19/20 Fountains at Summerfield - Deck Building Plans 5 of 5