Plans PHOTOVOLTAIC ROOF MOUNT SYSTEM RECEIVED � libH'.\ ° c '� 26 MODULES - SYSTEM SIZE STC (8.06 kW DC / 8.4 kW AC) DEC 14 2020 \ 'Hl i ,11 �' CITY OF TIGARD r � �i`�I � l�''%�' 16899 SW SNOWDALE ST, TIGARD, OR 97223, USA (45.42463, -122.85078) BUILDING DIVISION =R w l — — SYSTEM SUMMARY STC DC/AC SAFETY PLANS LOCATION OF NEAREST URGENT CARE FACILITY SHEET INDEX GREEN THINK ENERGY LLC NOTES: NAME: PV-1 SITE PLAN&SAFETY PLAN 50 HARRISON STREET, PV-2 ROOF PLAN WITH MODULES SUITE 202B (8.06 KW DC / 8.4 KW AC) • INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME. ADDRESS: PV-3 ATTACHMENT DETAIL SUITENJ • INSTALLERS SHALL UPDATE NAME,ADDRESS AND PHONE NUMBER OF PHONE NUMBER: PV-4 SINGLE LINE DIAGRAM HOBOKEN,www.Gree NJ 07030.com • 1X STRING OF 4 CONNECTED IN PARALLEL NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE PV-5 THREE LINE DIAGRAM • 1X STRING OF 3 CONNECTED IN PARALLEL STARTING WORK CONTRACTOR LIABILITY PV-6 WIRING CALCULATION 26 SUNTECH STP310S-20P_WFB MODULE: PROPERTY LINE 51 -6 PV-7 PLACARDS NAME:"'" - ( ) — — — — PV-8+ EQUIPMENT SPECIFICATION ADDRESS NA - (7) HOYMILES HM-1200N MICROINVERTERS The City of Tigard and its PHONER N/A employees shall not be "`E"sE""'" Approvebed plans REVISIONS 71 responsible for discrepancies ll on job s°*� PROJECT ID: N/A DESCRIPTION DATE REV sha I- I 30-3" which may appear herein. AHJ: GOVERNING CODES m I I WASHINGTON - 2017 OREGON ELECTRICAL SPECIALTY CODE ... ARRAY LOCATION 2017 OREGON RESIDENTIAL SPECIALTY CODE SIGNATURE&SEAL 2019 OREGON STRUCTURAL SPECIALTY CODE _________ h -" CITY OF TIGARD • �4' I REVIEWED FOR DE COMPLIANCE I I .• Approved: [ i OFFICE COPY OTC: [ - DD3zs i Permit : �� 1111 1 r PROJECT NAME Address: [l____ S I �ll I ii _� 'm� r jr1t k Sl 1tC#: ii�j ,rr,M,,; k GENERAL NOTES: B?. Date: 7 � EiR E� �� t�r , , I- < • ALL PANELS,SWITCHES, ETC.SHALL HAVE SUFFICIENT GU LE . _.. a .•, i I Z W SPACE AND LUGS IN COMPLIANCE TO UL REQUIREMENTS TO 0� I - -� +.. J ACCOMMODATE CONDUCTORS SHOWN. I • THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. I Pr mlli- I HOUSE PHOTO 0 o N • ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT 3'-11° SCALE: NTS INCLUDING THOSE THAT ARE EXPOSED TO OUTSIDE VALIDITY OF PERMIT 0 °' ENVIRONMENT SHALL BE WEATHERPROOF AND SHALL BE LISTED BY"UL"FOR THE TYPE OF APPLICATION AND"UL"LABEL THE ISSUANCE OF A PERMIT SHALL APPEAR ON ALL ELECTRICAL EQUIPMENT. BASED ON CONSTRUCTION m CI U) O • WIRING METHOD SHALL BE EMT ABOVE GROUND MOUNTED IN I Vanr'Quver CONCEALED SPACES(UNLESS APPROVED OTHERWISE)AND DOCUMENTS AND OTHER , . SCHEDULE 40 PVC FOR BELOW GROUND INSTALLATION DATA SHALL NOT PREVENT I I ' ' ' 0 UNLESS NOTED OTHERWISE. THE CODE OFFICIAL FROM 20-7'' 7Jf... ' PROJECT SITE 4:( Q • AN OSHA APPROVED LADDER PROVIDING ACCESS TO ALL PORTIONS OF THE ARRAY SHALL BE SECURED IN PRIOR TO REQUIRING THE CORRECTION e;vr- H+lls,;c-� 00 REQUESTING INSPECTION. OF ERRORS. ORSC 105.4 Z "IV Portland G. • IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A _ -- — m J SUPPLEMENTAL GROUNDING ELECTRODE CONDUCTOR IF L��''l�:�' II `v/ (�)��\Q� T 16H99 SW Snawdale Si, NECESSARY. �i " aM ' ` A 16899.ard OR 97223, USA M S P MAIN SERVICE PANEL AC AC DISCONNECT INV (0)INVERTER SUB SUB-PANEL EE EXISTING EQUIPMENT ` ROOF.ATTACHMENT ------ PROPERTY LINE I— SHEET NAME EXISTING (200A) UNFUSED WA NIA NIA M °I , l'n LOAD CENTER SITE PLAN & UM UTILITY METER ACF AC DISCONNECT LC (COMBINER PANEL) DCD DC DISCONNECT ■ OPTIMIZER — // —DIMENSIONS FENCE rn v SAFETY PLAN EXISTING FUSED NEW NEW N/A D - PM PRODUCTION METER JUNCTION BOX SOLAREDGE METER DCC COMBINER MICRO-INVERTER PV MODULE GATE N/A JB , NEW SM DC NA N/AO SHEET SIZE ANSI B BAT BATTERY AT AUTO TRANSFORMER BLP BACKUP LOAD PANEL 11" X 17" N/A N/A NA 3 VICINITY MAP SHEET NUMBER SITE PLAN & SAFETY PLAN SCALE: NTS PV-1 SCALE: 3/64" = 1'0" MODULE AREA & WEIGHT CALCULATIONS PANEL TYPES(COUNT,AREA,WEIGHT): LiE E C'� •(7x)Suntech STP310S-20P Wfb(65"x 39.1",40.3 LBS) i I\.\ ATTACHMENT COUNT:81 \ I ,\ MOUNTING SYSTEM WEIGHT/MODULE:1.5 LBS 2 »> - U TOTAL ARRAY WE GHT:' TOTAL ROOF AREA: 87)40.3+(7)1.5=293 LBS �.1� 6'-T' /I-6� 6' 0° 16' 8" ♦�X7 �U h� [� 2` 1 J/ TOTAL ARRAY AREA:(7)85.0"x 39.1"-123.55 SF 'I - �11I, WEIGHT AT EACH CONNECTION:293 LBS/81=3.61 LBS \ \ ♦♦♦O♦``a♦ GREEN HARHINK ENERGY RISON STREET, DISTRIBUTED LOAD:293 LBS/123.55 SF=2.37 PSF ♦♦♦♦ ♦�♦• SUITE N ST ROOF AREA COVERED BY ARRAY:124 SF/2448 SF=5.0% -\ I ♦♦♦♦�♦♦ _ - HOBOKEN,NJ 07030 ♦ i r nThlnkEne .com www.G ee BILL OF MATERIALS T --� -e, r�SOLAR PV MODULES 26 Suntech STP310S-20P_Wfb n _——— ,'d. % �:�`��♦,—��_ CONTRACTOR MICRO INVERTERS 07 Hoymiles HM-1200N .-- s � t°% """'E"I" LOAD CENTER 01 AC COMBINER PANEL(MIN RATING 40A) ——1 L—— F's1;Fig g� �;�'--- - ADDRESS:NIA 1' .9(° PHONE N NIA AC DISCONNECT 01 PV VISIBLE LOCKABLE ———-�—— -e9ot� ♦♦� v, - PHOLICENES a.N/A (60A FUSED 1LABELED DISCONNECT H 240VAC) ♦♦♦♦♦♦`�♦`♦„ •-•-`, REVISIONS ATTACHMENTS 61 IronRidge-FlashFoot2 \ -.-— —.- N �� ♦♦♦♦♦�'�♦- -1-- DESCRIPTION DATE REV RAIL - IronRidge-XR10 _�—�y-1 — \\ �♦♦.♦�♦_ --_ `��., —a--T— �— 74 'I.H �._+- - -•- —,�^ SIGNATURE&SEAL 4 0 , N\ -0--. -..-- - Itc‘i loi EC _ , .F _ ♦`�� ♦�. IM 011SI - . PROJECT NAME 4.♦ I I I I Q ?K —8'-6"- 1 —10' 7'-2" Z W D ROOF#1 -J ® oN o a' o v o (E) fKONNT YARD _ 6 Q (3) Q SW SNOWDALE 5T 0 co co H ROOF DESCRIPTION MAIN SERVICE PANEL AC DISCONNECT 0 INVERTER SUB-PANEL EXISTING • ROOF ATTACHMENT RAFTERS ARRAY RAFTERS RAFTERS SPACING MS P AC I NV ( ) SUB EE EQUIPMENT I— ROOF TILT AZIMUTH SIZE (ATTACHMENT SPACING) EXISTING (200A) uNFuseD wA N/A N/A m SHEET NAME LOAD CENTER 0 #1 37° 180° 2"X4" 24"OC(48°) UM UTILITY METER ACF AC DISCONNECT LC (COMBINER PANEL) DCD DC DISCONNECT • OPTIMIZER — // —DIMENSIONS ROOF RAILS EXISTING FUSED NEW NEW N/A m ROOF PLAN WITH 38° 90° z"xa" 24"OC(46") Z MODULES #3 37° 270° 2"X4" 24"OC(48") I PM PRODUCTION METER J B JUNCTION BOX SM SOLAREDGE METER DCC DC COMBINER . MICRO-INVERTER PV MODULE ////FIRE SETBACK 0 N/A NEW N/A WA SHEET SIZE BAT BATTERY AT AUTO TRANSFORMER BLp BACKUP LOAD PANEL ANSI B N/A N/A N/A 11" X 17" ROOF PLAN WITH MODULES SHEET NUMBER SCALE: 3/32" = 1'-0" PV-2 " o [ �, `\ 77f,,7 `Ctv V� PV MODULE s EN NK J11.L C GREEN THINK ENERGY LLC SEE (2/PV-4) FOR SO HARRISON STREET, � SUITE 2026 ENLARGED VIEW HOBOKEN,NJ 07030 www.Gree nThi nkEnergy.eem CONTRACTOR (E) SINGLE LAYER OF NAME N/A ADDRESS.NIA ' + COMPOSITE SHINGLE PNENSEaNA o ' ► REVISIONS RAFTERS DESCRIPTION DATE REV SIGNATURE&SEAL ATTACHMENT DETAIL SCALE: NTS PROJECT NAME PV MODULES IRONRIDGE INTEGRATED Z W GROUNDING & END/MID Q CLAMP N c IRONRIDGE XR10 RAIL (� O rn Z Et o � O � (E) SINGLE LAYER OF J COMPOSITE SHINGLE Q rn Q 0 c°80 , ALUMN. "L" BRACKET W/3/8" SS BOLT & NUT IRONRIDGE FLASH FLASHING FOOT2 ATTACHMENTS SHEET NAME ATTACHMENT I DETAIL 5l16"x3.5" SS LAG BOLT WITH MIN 2Yz" THREAD -4111111 EMBEDMENT, SEALED SHEET SIZE ANSI PENETRATION 11" X 17" 2 ATTACHMENT DETAIL (ENLARGED SECTION VIEW) RAFTERS SHEET NUMBER PV-3 SCALE: NTS NOTE: SYSTEM SUMMARY STC DC/AC •NOT ALL GROUNDING TO COMPLY W TH NEC 690.47. GROUNDING ELECTRODE CONDUCTOR/SYSTEM TyuI��� (8.06 KW DC / 8.4 KW AC) • ROOF TOP CONDUIT SHALL BE LOCATED MIN.7/8" BONDING JUMPER NOT REQUIRED FOR SOLAREDGE .JJ LI___ C_V ABOVE ROOF SURFACE. POWER OPTIMIZER.PROPERLY INSTALLED SYSTEM 1 jl r • 1X STRING OF 4 CONNECTED IN PARALLEL • ALL TERMINALS SHALL BE MIN.90 DEG.C RATED. MEETS THE REQUIREMENTS OF NEC 690.35 FOR li • 1X STRING OF 3 CONNECTED IN PARALLEL UNGROUNDED PV POWER SYSTEMS.PROVIDE b J - (26)SUNTECH STP310S-20P_WFB MODULES EQUIPMENT GROUNDING PER MANUFACTURER'S �_ n�C L ---•• - (7)HOYMILES HM-1200N MICROINVERTERS REQUIREMENTS IN COMPLIANCE WITH THE NEC. I . D i _:' IL L GREEN THINK ENERGY LLC 50 HARRISON STREET, SUITE 202B 1 HOBOKEN,NJ 07030 MAIN SERVICE PANEL www.GreenThinkEnergy.com MOD: Suntech STP310S-20P_Wfb (EXISTING, TOP-FED) INV: Hoymiles HM-1200N (240V) BUS RATING: 200A UTILITY METER CONTRACTOR UTILITY: PGE NAME NA ADDRESS.NIA MAIN BREAKER: 200A(E) (1 STRING X 4 MICRO INV) SERVICE: 240V 60HZ 1PH PHONE s.N/A LICENSE#N/A 4X 1 2 3 4 PV VISIBLE LOCKABLE 200 ` TO REVISIONS JUNCTION BOX AC COMBINER PANEL LABELED DISCONNECT IC VD — UTILITY GRID DESCRIPTION DATE60 T_ 01 UL NEMA3R (60A FUSED 1PH 240VAC) —r--. MS-01 UL LISTED LC-01 MCB 01 30A 50A —�� M -� LC 02 r 20A SIGNATURE 8 SEAL MOD: Suntech STP310S-20P_Wfb MCB-02 INV: Hoymiles HM-1200N (240V) ---e---6— (1 STRING X 3 MICRO-INV) ON 'OFF �� V 2X 1 2 3 4 2 3 -_,---,- N[S-02I/.I 1- PROJECT NAME Q z W D Q _10 > N o > P- o u) O AC wire details - Ic Wire Min Ampacity Live Neutral Ground Min EMT Min PVC Min RMC (1) MS-01 26.65A (2) 10 AWG PV 10 AWG PV 10 AWG THWN-2 0.75 in 0.75 in 0.75 in Q a) Q MS-02 19.99A (2)10 AWG PV 10 AWG PV 10 AWG THWN-2 0.75 in 0.75 in 0.75 in r n OD (r MCB-01 26.65A (2) 10 AWG THWN-2 10 AWG THWN-2 10 AWG THWN-2 0.50 in 0.50 in 0.50 in V CO '" MCB-02 19.99A (2)10 AWG THWN-2 10 AWG THWN-2 10 AWG THWN-2 0.50 in 0.50 in 0.50 in LC-01 46.64A (2)06 AWG THWN-2 06 AWG THWN-2 10 AWG THWN-2 0.75 in 0.75 in 0.75 in LC-02 46.64A (2)06 AWG THWN-2 06 AWG THWN-2 10 AWG THWN-2 0.75 in 0.75 in 0.75 in SHEET NAME INTERCONNECTION 120% RULE EXTREME CASE MODULE OUTPUT SINGLE LINE (MAIN PANEL) (Suntech STP31OS-20P_Wfb) DIAGRAM INTERCONNECTION Isc(25°C)=9.87A,Tisc=0.050%/°C 120% RULE Isc(T)= Isc(25°C)x[1 +Tisc x(T-25°C)] SHEET SIZE NOT APPLICABLE Isc(-15°C)=9.67A, Isc(45°C)=9.97A ANSI B Voc(25°C)=40.20V, Tvoc=-0.304%/°C 11° X 17" LINE-SIDE TAP DOES NOT AFFECT Voc(T)=Voc(25°C)x[1 +Tvoc x(T-25°C)] ELECTRICAL SINGLE LINE DIAGRAM MAIN PANEL Voc(-15°C)=45.09V,Voc(45°C)=37.76V SHEET NUMBER PV-4 SCALE: NTS SYSTEM SUMMARY STC DC/AC [T\!CF�,�1 (8.06 KW DC / 8.4 KW AC) / ! I�'' ,, .11� �1i • 1X STRING OF 4 CONNECTED IN PARALLEL ! )P41/ • 1X STRING OF 3 CONNECTED IN PARALLEL ' 'I' 1 U - (26)SUNTECH STP310S-20P_WFB MODULES - (7) HOYMILES HM-1200N MICROINVERTERS , � I`\JI � Di I7�,,/ I-, q'I :i GREEN THINK ENERGY LLC 50 HARRISON STREET, SUITE 202B HOBOKEN,NJ 07030 www.GreenThinkEnergy.com CONTRACTOR NAME N/A ADDRESS:N/A PHONE It N/A LICENSE k NIA REVISIONS DESCRIPTION DATE REV SIGNATURE 8 SEAL AC wire details WirelD #MICROS Nominal Backfeed*1.25 Min Total Conductor ccConductors Expected Temp Conduit fill Conductor& EGC size Conductor Insulation Max V drop Min EMT Min PVC Min RMC Voltage /cond. set OCPD Power sets /conduit max temp derate derate neutral size (Cu(Cu) metallengthsize size size MS-01 4 240 V 26.65 A 30 A 5.1 kW 1 2 45 0.87 ' 1.00 10 AWG 10 AWG Cu PV 50 ft 0.96% 0.75 in 0.75 in 0.75 in MS-02 3 240 V 19.99 A 20 A 3.8 kW 1 2 45 0.87 1.00 10 AWG 10 AWG Cu PV 50 ft 0.72% 0.75 in 0.75 in 0.75 in MCB-01 4 240 V 26.65 A 30 A 5.1 kW 1 2 45 0.87 1.00 10 AWG 10 AWG Cu THWN-2 50 ft 0.96% 0.50 in 0.50 in 0.50 in % MCB-02 3 240 V 19.99 A 20 A 3.8 kW 1 2 45 0.87 1.00 10 AWG 10 AWG Cu THWN-2 50 ft 0.72 0.50 in 0.50 in 0.50 in LC-01 7 240 V 46.64 A 50 A 9.0 kW 1 2 45 0.87 1.00 06 AWG 10 AWG Cu THWN-2 10 ft 0.14% 0.75 in 0.75 in 0.75 in LC-02 7 240 V 46.64 A 60 A 9.0 kW 1 2 45 0.87 1.00 06 AWG 10 AWG Cu THWN-2 10 ft 0.14% 0.75 in 0.75 in 0.75 in PROJECT NAME INTERCONNECTION 120% RULE EXTREME CASE MODULE OUTPUT ~ Q (MAIN PANEL) (Suntech STP310S-20P_Wfb) Z w n Isc(25°C)=9.87A,Tisc=0.050%/°C _I INTERCONNECTION 0 Isc(T)=Isc(25°C)x[1 +Tisc x(T-25°C)] Q CO NOT APPLICABLE Isc(-15°C)=9.67A, Isc(45°C)=9.97A rn ti Voc(25°C)=40.20V,Tvoc=-0.304%/°C V 0 CD LINE-SIDE TAP DOES NOT AFFECT Voc(T)=Voc(25°C)x[1 +Tvoc x(T-25°C)] D Z cc MAIN PANEL Voc(-15°C)=45.09V,Voc(45°C)=37.76V o CO 0 J ry 0 C) Q C _ ELECTRICAL NOTES to H 1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. 2) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3) WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. SHEET NAME 5) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6) WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED,THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. WIRING 7) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. CALCULATION 8) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NEC 690. SHEET SIZE 11) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF INSTALL. ANSI B 12) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER NEC 310.15(B)(16). 1 1" X 17" SHEET NUMBER PV-5 . A4MA e AWARNING A WARNING PHOTOVOLTAIC POWER SOURCE 5 ;T riV CAUTION PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC SYSTEM _I IL_ CIRCUIT IS BACKFED COMBINER PANEL LABEL LOCATION:DC CONDUIT JUNCTION BOX NO MORE THEN 10FT C ; 1L -) 1�J CODE REF:NEC 690.13(B) Q \r� ,1/ LABEL LOCATION:BACKFED BREAKER DO NOT ADD LOADS `���--- IIJJ CODE REF:NEC 705.2(4) nWARN I N G GREEN THINK ENERGY LLC A PHOTOVOLTAIC SYSTEM 50 HARRISON STREET, SUITE 202B LABEL LOCATION:AC COMBINER PANEL ,Q INVERTER OUTPUT HOBOKEN,NJ 07030 CODE REF:NEC 690.12(B) CONNECTION UTILITY DISCONNECT SWITCH www.GreenThinkEnergy.com AWARNING DO NOT RELOACATE THIS LABEL LOCATION:AC DISCONNECT CONTRACTOR A INVERTER OUTPUT CONNECTION A CODE REF: UTILITY NAME'AWARNING RN I N G OVERCURRENT DEVICE NAMEA NI SS N/A PHONE*NIA DO NOT RELOCATE THIS ELECTRICAL SHOCK HAZARD LICENSE R.N/A OVERCURRENT DEVICE TERMINALS ON BOTH LINE AND LABELSERVICELOCATION:IF APPLICABLE REVISIONS LOAD SIDES MAY BE ENERGIZED IN CODE REF:NEC 705.12(D)(7) DESCRIPTION DATE REV LABEL LOCATION:BACKFED BREAKER THE OPEN POSITION CODE REF:2017 NEC 705.12(2)(3)(b) DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE AWARI G CA T I N . WARNING EXPOSED TO SUNLIGHT 16 /.� AGE SCOURGE IS CONNECTED TO THE SUPPE V(UTILrT LABEL LOCATION:DC DISCONNECT,COMBINE BOX ELECTRICAL SHOCK HAZARD • SIGNATURE&SEAL / .� \ SIDE Er INSERVICE DISCO"NECT.FOLLOWTHEPROPER CODE REF:NEC 690.13(B) POWER TO THIS SERVICE IS ALSO SUPPLIED LOCK-OUTiTAG-OUT PROCEDURES TO ENSURE THE PHOTOVOLTAIC IF GROUND FAULT IS INDICATED SYSTEM UTILITY FORMINNECTSwNCHISDEVICE PRIOR TO FROM THE FOLLOWING SOURCES WITH PERFORMING WORK ON THIS Device ALL NORMALLY GROUNDED n PV SOLAR BREAKER CONDUCTORS MAY BE DISCONNECTS AS SHOWN LABEL LOCATION:(IF APPLICABLE)SUPPLY SIDE TAP UNGROUNDED AND ENERGIZED LOAD PANEL CODE REF:UTILITY DO NOT RELOCATE THIS /� OVERCURRENT DEVICE LABEL LOCATION:AC DISCONNECT �� .,, COMBINER BOX SERVICE PANEL 'elk PROJECT NAME APHOTOVOLTAIC AC DISCONNECC CODE REF: NEC 690.5(C) RATED AC OPERATING CURRENT: 26 AM DEADLABELFRONT LOCATION:MAIN PANEL NOMINAL OPERATING AC VOLTAGE: 240 VAC CODE REF:NEC 705.12(B)(2)(3)(B) Q LABEL LOCATION:MAIN PANEL AC DISCONNECT(S) i z uJ D CODE REF:NEC690.54 �, SOLAR s7srTEM EQUIPPE A Pi/ Q J Q N RAPID SHUTDOWN SWITCH WITH RAPID SHUTDOWN 0 ocn A FOR SOLAR PV SYSTEM r 0 v o J p_ LABEL LOCATION:MAIN PANEL TURN RAPID SHUTDOWN U) ry CODE REF:NEC 690.12 SWITCH TO THE "OFF" LANCLEC.RIQ: — CD Q POSITION TO SHUTDOWN PANELS V pp 0 A WARNING PV SYSTEM AND REDUCE - PV ARRAY co '- SHOCK HAZARD IN THE _ m 6 ARRAY. ELECTRICAL SHOCK HAZARD dSN EOV TERMINALS ON BOTH LINE AND -IN(1 011 SHEET NAME LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION • i LABEL LOCATION:MAIN SERVICE - JUNCTION BOX PLACARDS CODE REF:NEC 690.12 LABEL LOCATION:COMBINER PANEL AC DISCONNECT NEC 690.56(C)(1)(A) UTILITY JUNCTION BOX INVERTER(S) SHEET SIZE CODE REF:NEC690.13(b) CAUTION AC DISCONNECT - - INVERTER ANSI B PHOTOVOLTAIC U DUA L POWER SOURCE SECOND i i" X 17" A SYSTEM METER SCORCE IS PHOTOVOLTIC SHEET NUMBER LABEL LOCATION:SERVICE METER PV-6 MAIN PANEL CODE REF: UTILITY HyPro STP310S - 20/Wfb J SUNTECH HyPro STP310S -20/Wfb J SUNTECH t' C i STP3OSS - 20/Wfb STP305S -20/Wfb GREEN THINK ENERGY LLC 60 HARRISON STREET, STP300S - 20/Wfb STP300S - 20/Wfb SUITE 20213 HOBOKEN,NJ 07030 1 1�/ Electrical Characteristics www.GreenThinkEnergy.com �, 310 0 Watt att sstln0=aooel SIC STP311OS-201 STP30VSSS 20/ 5TP300fb 055-201 Wfb NAME.N/A CONTRACTOR u2131.Wii5t MONOCRYSTALLINE SOLAR MODULE01/1 Maximum Power at STC(Pmax) 310W 305W 300W ADDRESS N/A - -- ------------ 1.. ....." Optimum Operating Voltage(Vmp) 33.1V 328V 32.5V PHONE d-.NIA r� \` d-ds haw nccrvsEa N/AFeaturesOptimum Operating Current(Imp) 9.37A 930A 923A 0xasess._e.al e.m-. Open Circuit Voltage(Voc) 40.2V 39.8V 396V REVISIONS ♦♦ High module conversion PlD resistant ♦ 1i1�1 Short Circuit Curtest(Isc) 9.87 A 9.80 A 9.72 A DESCRIPTION DATE REV .♦♦yI efficiency Lir_J Advanced cell technology - - � -i - - o, Module efficiency up to nu and qualified materials lead to Module Efficiency 18.9% 18.6% 18.3% 18.9b 18.9%achieved through aep,tant high resistance to PID Operating Module Temperature -40°C to+85°C advanced cell technology and e[ +A (earls yawl a /7 N Maximum System Voltage 1000V DC(UL) manufacturing capabilities Section A-A I E E f Maximum Series Fuse Rating 20 A Positive tolerance p © Suntech current sorting >R g , 1 Power Tolerance 0/+Sw SIGNATUREBSEAL Positive tolerance of up to D`p process 'I'� �I'�IlliI�II(„• s;r*d wmwmndlscareamanhon 1A ZS C AM,,s. ah1" m,�n.vn<.ne l:<areaxahn ts� 0l+5w 5W delivers higher outputs 2"• System output maximized by 11csl flfl III reliablity reducing mismatch losses up (Front view) tot%with modules sorted& Nom,rrm(inchl .�IIIIII .• IIII���I NMOT STP3705-ZDI 5TP3055 20!wPo WPo WPo STP3oo5-201 ! packaged by amperage - - - Maximum Power at NMOT(Pmax) 2326W 2263W 225.0W 1 lI Extended load tests Withstanding harsh Optimum Operating Voltage(Vmp) 30.8V 30.5V 30.3V �•� Module certified to withstand environment Optimum Operating Current(Imp) 7.55A 749A 7.43A eaaora front side maximum static Reliable quality leads to a Open Circuit Voltage(Voc) _ 37.6V 37.1 V 37.OV 1 Saoova test load(5400 Pascal)and better sustainability even in Current-Voltage&Power-Voltage Curve(310S) Short Circuit Current(Isc) 7.97A 7.92 A i 7.85 A I PROJECT NAME rear side maximum static test harsh environment like desert, „ ,e, loads(3800 Pascal)* farm and coastline "ant""`"°"�"W m`" "�"m� °rtA•` -"���eoa, m --- -- --- Temperature Characteristics C - I� CE I _ Certifications and eroMprds: SPe �* -- Nominal Module Operating Temperature(NM0T) 4222°C Q IFC 61715,IE[61]3a,cmfomdtyroCF r " e c trs -� _ '°°€ Temperature Coefficient of Pmax -03796/°C (n ,,o i Temperature Coefficient of I -0.304%/°C Z Ill D t Trust Suntech to Deliver Reliable Performance Over Time ! Special 5 busbar design . _!T - II. Temperature Coefficient of lsc 0.050%PC Q •World-class manufacturer of crystalline silicon photovoltaic modules The unique cell design leads CO 0 reduction in electrodes ,.� .. N •Unrivaled manufacturing capacity and world-class technology •Rigorous quality control meeting the highest international standards: resistance,shading area and Mechanical Characteristics 0 (` I ISO 9001:2008,ISO 14001:2004 and 15017025:2005 raise in conversion efficiency. a a w a, M Solar Cell Monocrystalline silicon 6 inches 0 Residual stress distribution can va`r*o0 •Regular independently checked production process from international No.of Cells 60(6 x 10) Z accredited institute/company be more even,reducing the h,m.,.+=o.n*-w•-+-wows+-m r.+ Dimensions 1650 x 992 x 35mm(65A x 39.1 x 1.4 inches) 0 CO 0 •Tested for harsh environments(salt mist,ammonia corrosion and sand micro-cracks risks. ^ Weight 18.3 kgs(403 lbs.) blowing testing:IEC 61701,IEC 62716,DIN EN 60068-2-68)*** Front Glass 3.2 mm(0.13 inches)tempered glass •Long-term reliability testsests •2 x 10096 EL Inspection ensuring defect-free modules Frame Anodized aluminium alloy Q Dealer information Junction Box IP68 rated(3 bypass diodes) 's c Industry-leading Warranty based an nominal power IP68 Rated Junction Box V 0 Output Cables 4.0 min'(0.006 inches'),symmetrical lengths(-)1000mm(39.4 CO •97.5%in the first year,thereafter,for The Su ntech I P68 rated inches)and(+11000 tram(39A inches) CO H years two twenty-five junction box ensures an Connectors MC4 compatible (25),0.7%maximum decrease from outstanding waterproof /odusay eactingMODULE''S nominal power output level,supports installations r year,ending with the 80.796 in all orientatios and .. 11rwarrantp in the 25th year fter the defined reduces stress on the cables. Packing Configuration WARRANTY STARTING DATE.""*" High reliable performance, Container : 20'GP 40'HC ' SHEET NAME 1 10 '5.12-year product warranty low resistance connectors Pieces per pallet 30 30 •25-year linear performance ensure maximum output Pallets per container 6 28 EQUIPMENT warranty for the highest energy - -- -- - - - - production. Pieces per container j 180 840 '.,, SPECIFICATION Hpmabn en hot,to imMl em m.Ote an prod.da+tlhha M the lain.,OnO O.MYakaadlueed IRMs Ana Men m suym On champ*ma prim anvarmr-tThe•pecx..dms l".Y wnalrhdY,M,R.d.mlmn.re In .awenice with sarcLN 114301 O.Lam<Aweoce,Nt a nM,l.Mane to 119112991 to well n dAc&Mad,ns MM the nodule,with do AA SAW theN proper lu c trwq are pasWe W PR n t tomPwre a Mlmlm horn the,pedtwtioo. 'Please refer to Suntech Standard Module Installation Manual for details. ••WEEE only for EU market. SHEET SIZE Please refer to Suntech Product Near-coast Installation Manual for details. ••••Please refer to Suntech Product Warranty for details. ANSI B 11" X 17" toCopyright 2019 Suntech Po::c• www.suntech-power.com UL-STP-Wfb-NO2.01-Rev 2019 .®Copyright 2019 Suntech Power ': www.suntech-powercom UL-STP-Wfb-NO2.01-Rev 2019 SHEET NUMBER PV-7 _ -r..r- ---- The World's Safest 1 .7)17,7 hoymiles solar solution for you and your family a fiU '' GREEN THINK ENERGY LLC 50 HARRISON STREET, SUITE 202B Model HM-1000N HM-1 200N HM-1500N HOBOKEN,NJ 07030 www.GreenThinkEnergy.com Input Data (DC) CONTRACTOR Commonly used module power 1 W) 200-310 240-380 300-470 NAME.N/A Module compatibility 60 cell or 72-cell PV modules 60-cell or 72-cell PV modules 60-cell or 72-cell P✓modules ADDRESS:N/A PHONE C NIA Peak power MPPT voltage range(V) 27-48 29-48 36-48 LICENSE le N/A Start-up voltage(V) 22 22 22 REVISIONS Operating voltage range(V1 16-60 16-60 16-6D DESCRIPTION DATE REV Maximum input voltage(V) 60 60 60 Maxfrnum input current (A) 4'10.5 4.11.5 4'11.5 • Output Data (AC) Peak output power(VA) 1000 1260 1200 1500 1350 SIGNATURE&SEAL Maxmum continuous output power (VA) 958 1200 1109 1438 1246 ii Maximum continuous output current 3.99 4.61 5 5.33 5.99 5-99 Nominal output voltage/range(V) 240/211-264' 208/183-228' 240/211-264' 208/183-228' 240/211-264' 208/183-228' Nominal frequency/range(VI 60/55-65 ' 60/55-65 ' 60/55-65 ' >0.99 default >0.99 default >0.99 default Power factor(adjustable) 0.85 leading...0.65 lagging 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging Total harmonic distortion <3% <3% <3% PROJECT NAME Maximum units per branch' 4 3 3 3 2 2 Efficiency CEC peak efficiency 96.70% 96.70% 96.70% I— Q CEC weighted efficiency 96.50% 96.50% 96.50% CO co Nominal MPPT efficiency 99.80% 99 80% 99 80% Z LU D Nighttime power consumption(mW) <50 <50 <50 //Qrr�� < c Mechanical Data Lt'!� o N Ambient temperature range("C) 40 +65 ( Dimensions(W=H=D mm) 280 x 176 x 33 Q 0 O Weight(kG) 3 75(including 2 32m AC cable) Enclosure rating Outdoor-NEMA(1P67) —I Q Cooling Natural convection- No tans _ W 12 Features Q CY) Q Communication 2.4GHz Proprietary RF{Nordic) 1"1 0) Ur Monitoring Hoymiles Monitoring System V/ (p H Compliance uL1741.1EEE1S47,Ut1741 SA L240Vac).CA Rule21(240Vac1 C5A C22.2 No 107.1-16,FCC 1S8 FCC 1SC PV Rapid Shutdown Conforms with NEC-2014 and NEC-2017 Article 69012 and CEC-2018 Sec 64-218 Rapid Shutdown at Pv Systems -t 4:mi11e vv'euer'regtrenLS'any*teM1 Pt t'an,yee due te IN.tedeeee.ents of Iota'powe,/VI.,rn-e+: •2 aafr in+Ace requirements for exact number of micm0,nnKbrs per franc},. SHEET NAME Hiah Reliability Based on World's Top Supplier Partners EQUIPMENT SPECIFICATION Maatacooe CREE= EP os SHEET SIZE (ja} 110 muNata t_ . „J 1ANSI 1B �r kf1RMC=TS n 11 SHEET NUMBER PV-8 D C ! 1ii A_ Datash Datasheet ,�� R NRIDGE Flush Mount S stem XR Railse ����� � ION y GREEN THINK ENERGY LLC XR10 Rail XR100 Rail XR1000 Rail Bonded Splices 50 HARRISON STREET, SUITE 202B HOBOKEN, . www.Green ThinkEnergy.com NJ07030 1is a CONTRACTOR _ NAME.N/A _________:„........ �� _s __ ADDRESS N/A PHONE i'N/A 3 LICENSE*N/A t< A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. REVISIONS • 6'spanning capability • 8'spanning capability • 12'spanning capability Sell-drilling screws DESCRIPTION DATE REV • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear and black finish • Clear and black finish • Clear anodized finish • Forms secure bonding ,;. - Clamps&k Grounding ti — SIGNATURE&SEAL a ; UFOs Stopper Sleeves Grounding Lugs Microinverter Kits - --� J&..�— �taw-- Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount Mls or POs to XR PROJECT NAME ",. •` bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled&tubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single,universal size • Sized to match modules • Single tool installation • Kit comes assembled . Q • Clear and black finish • Clear and black finish • Mounts in any direction • Listed to UL 2703 (/) u) ttiilt fnr 5nlar's touttheSt roofs Z LU D h ttnialirtentsED -..__. ..... - ` _J .. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to �G�II��� < N the limit and proven in extreme environments. FlashFoot2 Slotted L-Feet Bonding Hardware Flush Standoffs �V 0 N Our rigorous approach has led to unique structural features, such as curved rails and reinforced(lashings, and — ^ __- 21 V is also why our products are fully certified,code compliant and backed by a 20-year warranty. ri E Z O Strength Tested PE Certified 1- *- �- J Cr) 0 All components evaluated for superior PE/ Pre-stamped engineering letters Rash and mount XR Rails Drop-in design for rapid rail Bond and attach XR Rails Raise Flush Mount System Q/r'� 0) < structural performance. V available in most states. with superior waterproofing. attachment. to roof attachments. to various heights. V (3 • Twist-on Cap eases install • Secure rail connections • T&Square Bolt options • Works with vent flashing CO I— • Wind-driven rain tested • Slot for vertical adjusting • Nut uses 7/16"socket • 4"and 7"lengths 1— 6Class A Fire Rating Design Assistant • Mill and black finish • Clear and black finish • Assembled and lubricated • Ships assembled Certified to maintain the fire resistance Online software makes it simple to rating of the existing roof. create,share, and price projects. Resources SHEET NAME Design Assistant ,,, NABCEP Certified'Training EQUIPMENT UL 2703 Listed System 0 20-Year Warranty Go from rough layout to fully 4,n': Earn free continuing education credits, ma: SPECIFICATION O Entire system and components meet Twice the protection offered by engineered system. For free. while learning more about our systems. newest effective UL 2703 standard. competitors. Go to IronRidge.com/design U onRidge.com/training l -1 SHEET SIZE ANSI B t rfrASHEET NUMBER PV-9 f D 77 !i //lr IRONRIDGE Integrated Grounding System Installation Overview GREEN THINK ENERGY LLC 60 HARRISON STREET, Install Roof Attachments SUITE HOBOKEN,NJ NJ 07030 Simplified Grounding 1 — • Install appropriate roof flashing and/or standoff for roof type. www.GreenThinkEnergy.com Fnr ffrPafpr Safr_ty R I niivPr Cny •Attach L Feet to flashing or standoff.Attach NAME NIA ADDRESS'.N/A Traditionally, solar modules are grounded by attaching PHONE#.NIA lugs, bolts or clips to the module frame,then connecting Prepare Rail Connections I---- LICENSE a.N/A , these to a copper conductor that runs throughout the ' REVISIONS array.This process adds time and cost to the installation, • Insert splice into first railZ. ,then secure with Grounding Strap and and often results in improper grounding, creating self-drilling screw. /' DESCRIPTION DATE REV significant long-term safety risks. • Slide second rail over splice,then secure with opposite end of .- The IronRidge Integrated Grounding System solves these Grounding Strap and self-drilling screw. challenges by bonding modules directly to the mounting SIGNATURE&SEAL rails.This approach eliminates separate module Mount&Ground Rails : grounding hardware, and it creates many parallel 7.,; , grounding paths throughout the array, providing Attach rails to L-Feet and level rails. ;� greater safety for system owners. Grounding Mid Clamp • Install one Grounding Lug per row of modules. Each Grounding Mid Clamp pierces through thel anodized coatings of both the module frame and • Connect Grounding Lug to grounding conductor. the mounting rail to form secure electrical bonds, which are repeated throughout the array. { - - _ Install Modules&Clamps PROJECT NAME Install first additional modules us around r d Clamps.d Cla p - moduleusing End Clamps d G ding M' in s - using Grounding M :: • Finish row with a second air of End Clamps. ` ~ Q • P P Z wD - • Testing & Certification 0 Qp N ' - _ , r In Module Frame Compatibility � 1 The IronRidge Integrated Grounding —_..__ O" � i's.--...---"------.,' ' System has been tested and certified to .._ Dimension Range D z cc '^ / �` _• UL 2703 by Intertek Group plc. y /// A 31.0mm 51.0mm Q Cr) Q �� ��� �� A B 5.08mm(minimum) �., UL 2703 is a proposed UL standard J ❑ ��` for evaluating solar module mounting Any module frames whose parameters are not fated in the w u- and clamping devices. It ensures theseL provided table have not been tested for compatibity. C` Q �` devices will maintain strong electrical and 1 C0 0) CD ��� © mechanical connections over an extended COe F- period of time in extreme outdoor The Grounding Clamp has proven robust in grounding 60-cell and so I t 72-cell solar module frames with box construction and a range of / - ^^ . environments. anodization thicknesses. © \.'A•; The testing process closely mirrors that All solar modules listed to UL 1703 and with frame construction Grounding Strap / I 1 of UL 1703,the solar module testing within the parameters stated above are compatible with the SHEET NAME Grounding Straps are used to /, standard, including temperature and IronRidge Integrated Grounding System. .i.. o bond rail-to-rail connections. GroundingLug EQUIPMENT g humidity cycling,electrical and mechanical They are only required on the A single Grounding Lug O SPECIFICATION rail with the grounding lug. connects an entire row load testing, and manufacturing quality Go to ironridge.com/ig of PV modules to the reviews. grounding conductor. I SHEET SIZE ANSI B SHEET NUMBER PV-10 __ _ -_. _ M. .: • GREEN THINK ENERGY LLC ', 50 HARRISON STREET, IRONRIDGE UFO Family of Components System Diagram SUIISON STREET, HOBOKEN,NJ 07030 www.GreenThinkEnergy.com CONTRACTOR Simplifleu t routiuitty iui E.rt i y Application rip C)- -I 11- : -0 0 • 4,: NAME NIA ADDRESS'NIA The UFO family of components eliminates the need for ,- LICENSE."NA separate grounding hardware by bonding solar modules directly to IronRidge XR Rails.All system types that feature REVISIONS the UFO family—Flush Mount,Tilt Mount and Ground DESCRIPTION DATE REV Mount—are fully listed to the UL 2703 standard. =D 0 O- - -1 I I- - =0 0 a= UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system.This leads to safer and more ,�� SIGNATURE&SEAL reliable installations. _ IIIIIIIIII�m ....■ Ell III OE �..F Stopper Sleeve Universal Fastening Object(UFO) The Stopper Sleeve snaps The UFO securely bonds solar modules to XR p onto the UFO,converting it into f Rails-It comes assembled and lubricated,and -� 0 0- _ _I I I_ _ =0 •� PROJECT NAME '' a bonded end clamp. can fit a wide range of module heights. • fsCr) co y 6\ O UFO C Stopper Sleeve • Grounding Lug I I I Bonded Splice —1— Ground Wire z LU D A . --",, • . ,/::' -:. •- i --_ • //- <' Q Approved Enphase microinverters canprovide equipment roundin of IronRidge systems,eliminatingthe need for > r� J PP P grounding 9 Y - �.• grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the 0 CD : . • / - - - /!4 / same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. Z D -Spill /� • �•+ �`` UL Certification J 0 f - /J Y Cross-System Compatibility Cn il i � The IronRidge Flush Mount, Feature Flush Mount Tilt Mount Ground Mount 0 6) - Tilt Mount, and Ground Mountco Bonded ��" Systems have been listed to UL XR Rails d d XR1000 Only Each Bonded Splice uses \ 2703 by Intertek Group plc. UFQIStopper V d - - W self-drilling screws to form r a secure connection,No \ UL 2703 is the standard for Bonded SpliceN/A bonding strap needed. \� evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array ' systems. It ensures these devices SHEET NAME will maintain strongelectrical and Microinverters Enphase-M250-72,M250-60,M215-60,C250-72 &Power Darfon-MIG240,MIG300,G320,G640 EQUIPMENT Ny Grounding Lug mechanical connections over A single Grounding Lug Bonded Attachments Optimizers SolarEdge-P300, P320, P400, P405. P600, P700, P730 SPECIFICATION }mom connects an entire row The bonding bolt attaches an extended period of time in I of PV modules to the and bonds the L-foot to the extreme outdoor environments. Fire Rating Class A Class A N/A grounding conductor. rail.It is installed with the Tested or Evaluated with over 400 Framed Modules ^ SHEET SIZE same socket as the rest of the Modules system. Q Go to IronRidge.com/UFO Refer to installation manuals fora detailed list. ANSI B 11" X17" SHEET NUMBER ',_«call 7-a00-2276523 for more! ,