Loading...
Report 2020 - 001,2 OFFICE COPY 1550 SW clarlyhack.hst. RECEIVED • ADT Commercial DEC 16 20T0 9350 S.W. Nimbus Ave CITY OF TIGARD Beaverton, OR 97008 BUILDING DIVISION 503-469-7113 Reference: Fire Alarm System: Costco #111 - Tigard 7850 S.W. Dartmouth Street Tigard, OR 97223 s Device Data Sheets Nov 2020 DF-60957:C ES-200X • Intelligent Addressable FACP with Communicatorp by Honeywell Iu Pii � ..... . • e �,r re4l Fire Alarm Control Panels General , The ES-200X is the latest intelligent addressable Fire Alarm Control Panel(FACP)from Fire•Lite Alarms and is a direct replacement for r :vat the MS-92000DLS. The ES-200X comes with a pre-installed corn- municator and supports up to 198 addressable devices (99 detec- tors and 99 modules).With an extensive list of powerful features,the &Mel& - ES-200X programs just like Fire•Lite's other addressable products, Yet fits into applications previously served only by conventional an- ti�u els. l , Fe The pre-installed IPOTS-COM is a dual technology(POTS and IP) �, .. communicator.The POTS transmits system status(alarms,troubles, - ° AC loss,etc.)to a Central Station via the public switched telephone network.The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- 'I cated business telephone lines.Although not required, the second- ti ` uv} ary telephone line may be retained providing backup communication over the public switched telephone line.Optional cellular reporting is available using the CELL-MOD or CELL-CAB-FL. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port(and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file,walk-test data,current status and system volt- ▪ Alarm verification selection per detector point ages by means of a USB flash drive. • Maintenance alert warns when smoke detector dust accumula- . The power supply and all electronics are contained on a circuit tion is excessive board supported on a new quick install chassis and housed in a • One-person audible or silent walk test with walk-test log and metal cabinet. Available accessories include local and remote printout upload/download software,remote annunciators,and reverse polar- • System alarm verification selection per detector point ity/city box transmitter(4XTMF). • PAS (Positive Alarm Sequence)and Pre-signal per point(NFPA Features 72 compliant) • Up to 16 ANN-BUS annunciators-8 per each ANN-Bus • Listed to UL Standard 864, 10th edition • Remote Acknowledge, Alarm Silence, Reset and Drill via • Pre-installed IPOTS-COM Ethernet IP and POTS(Plain Old Tele- addressable modules or remote annunciator phone Service)Central Station Communicator over AlarmNet • Upload/Download of program and data via USB with optional FS- • Optional CELL-MOD or CELL-CAB-FL GSM Central Station Tools Programming Utility Communicator over AlarmNet® • Automated activation of the ECC-50/100 Emergency Command SLC COMMUNICATION LOOP Center • Supports LiteSpeedTM and CLIP protocols • ECC-FFT Firefighter Telephone option • SLC operates up to 10,000 ft. (3,000 m)in LiteSpeed mode with • Compatible with SWIFT®wireless devices twisted,unshielded wire • Auto-programming (learn mode) reduces installation time. • Single addressable SLC loop which meets NFPA Class B and Reports two devices set to the same address Class A requirements • Four built-in, independently programmable Style Z (Class A) or Style Y(Class B)NAC circuits • 198 addressable device capacity (99 addressable detectors and • Selectable strobe synchronization for System Sensor,Wheelock, 99 modules) and Gentex devices • Compatible with Fire•Lite's addressable devices (refer to the • Notification Appliance Circuit End of Line resistor matching SLC Wiring Manual) • Four programmable function keys for ease of maintenance NOTIFICATION APPLIANCE CIRCUITS(NAGS) • Two programmable relays and one fixed trouble relay Built-in Programmer • Four independently programmable output circuits.Circuits can be •• Integral 80-character LCD display with backlighting configured for the following outputs: • Real-time clock/calendar with automatic daylight savings control —Style Y(Class B) • History file with 1,000 event capacity —Style Z(Class A) • Addressable sounder base compatibility • Silence Inhibit and Autosilence timer options • Multi-criteria detector (smoke, heat, CO) with programmable • Continuous, March Time, Temporal, or California code for main response circuit board NACs with two-stage capability • Control module delay timer • Selectable strobe synchronization per NAC . • Automatic detector sensitivity testing(NFPA 72 compliant) • Automatic device type-code verification • 2.5 A special application,250mA regulated,total power for NACs • Point trouble identification NOTE:Maximum or total 24VDC system power shared between all NAC • Waterflow selection per module point circuits and the ANN-BUS is 2.7 A OF-60957,C•7/16/2018—Page 1 of 4 PROGRAMMING AND SOFTWARE PRN Series: UL listed compatible event printer. Uses tractor-fed • • Autoprogramming (learn mode)reduces installation time paper. • Custom English labels (per point) may be manually entered or OPTIONAL MODULES selected from an internal library file Two programmable Form-C relay outputs 4XTMF Reverse Polarity Transmitter Module: Provides a super- • vised output for local energy municipal box transmitter, alarm and • 99 software zones trouble.Includes a disable switch and disable trouble LED. • Continuous fire protection during online programming PWRMOD24 Power Expander Module: Optional power module. • Program Check automatically catches common errors not linked Increases alarm power output to 6 amps. to any zone or input point COMPATIBLE ANNUNCIATORS • OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools,a Windows®-based software package,and ANN-80: Remote LCD annunciator mimics the information dis- upload/download system programming locally. Offline program- played on the FACP LCD display. Recommended wire type is un- ming requires an ethernet connection. FS-Tools is available on shielded. www.firelite.com. ANN-100: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- User interface shielded.For use in FM applications only. LED INDICATORS ANN-I/O: LED Driver Module provides connections to a user sup- plied graphic annunciator.(See DF-52430.) • Fire Alarm(red) ANN-LED:Annunciator Module provides three LEDs for each zone: • CO Alarm(red) Alarm,Trouble,and Supervisory.Ships with red enclosure.(See DF- • AC Power(green) 60241.) • Supervisory(yellow) ANN-RLED: Provides alarm(red)indicators for up to 30 input zones Trouble(yellow) or addressable points. (See DF-60241.) • Ground fault(yellow) ANN-RLY:Relay Module provides 10 programmable Form-C relays. • Can be mounted inside the cabinet.(See DF-52431.) • Battery fault(yellow) ANN-S/PG: Serial/Parallel Printer Gateway module provides a con- • Disabled(yellow) nection for a serial or parallel printer. (See DF-52429.) • Maintenance(yellow) ADDRESSABLE DEVICES • Communication(yellow) All feature a polling LED and rotary switches for addressing. • Alarm Silenced(yellow) SD365:Addressable low-profile photoelectric smoke detector. Lite- • F1-F4 Programmable Function Keys(yellow) Speed only. • KEYPAD SD365-IV: Addressable low-profile photoelectric smoke detector. • 16 key alpha-numeric pad Ivory.LiteSpeed and CLIP mode. Acknowledge SD365T:Addressable low-profile photoelectric smoke detector with • Alarm Silence thermal sensor.LiteSpeed only. • Drill(Manual Evacuate) SD365T-IV: Addressable low-profile photoelectric smoke detector • with thermal sensor. Ivory.LiteSpeed and CLIP mode. • Four(4)programmable function keys SD365R: Remote test capable addressable photoelectric smoke • Reset(lamp test) detector for use with DNR(W)duct detector housing.LiteSpeed only. PRODUCT LINE INFORMATION SD365R-IV: Remote test capable addressable photoelectric smoke ES-200X:Addressable Fire Alarm Control Panel with one SLC loop. detector for use with DNR(W) duct detector housing. Ivory. Lite- Includes main circuit board with display,pre-installed communicator, Speed and CLIP mode. chassis with transformer, backbox with door, plastic bag containing H365:Low-profile 135°F fixed thermal sensor.LiteSpeed only. screws,cables,key,etc. (For ES-200XC,refer to DF-60958.) H365-IV: Low-profile 135°F fixed thermal sensor. Ivory. LiteSpeed FS-Tools: Programming software for Windows®-based PC com- and CLIP mode. puter.Available for download at www.firelite.com. H365R: Low-profile, intelligent, rate-of-rise thermal sensor. Lite- CELL-CAB-FL/CELL-MOD:Optional GSM communicators. Speed only. IPOTS-COM: Dual technology (POTS and IP) communicator. H365R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. (replacement board) LiteSpeed and CLIP mode. DP-ES-R:Optional dress panel for the ES-200X. H365HT: Low-profile intelligent 190°F/88°C fixed thermal sensor. TR-CE:Optional trim ring for semi-flush mounting. LiteSpeed only. BB-2F:Optional cabinet for one or two modules. H365HT-IV: Low-profile intelligent 190°F/88°C fixed thermal sensor. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 Ivory. LiteSpeed and CLIP mode. chassis. Legacy Devices B8-26: Battery backbox, holds up to two 25 AH batteries and CHG- CP355:Addressable low-profile ionization smoke detector. 75. SD355:Addressable low-profile photoelectric smoke detector. BB-55F: Battery box,houses two 55 AH batteries SD355T:Addressable low-profile photoelectric smoke detector with CHS-6:Chassis,mounts up to six multi-modules in a BB-6F cabinet. thermal sensor. CHG-75:Battery charger for lead-acid batteries with a rating of 25 to SD355R: Remote test capable addressable photoelectric smoke 75 AH. detector for use with DNR(W)duct detector housing. CHG-120F: Remote battery charging system for lead acid batteries SD355CO:Addressable, low-profile device that provides fire, heat, . with a rating of 55 to 120 AH.Requires additional BB-55F for mount- ing. and carbon monoxide(CO)detection. BAT Series:Batteries,see data sheet DF-52397. H355: Fast-response,low-profile heat detector. . . .. . . ,, . ... Page 2 of 4—DF-60957:C•7/16/2018 H355R: Fast-response, low-profile heat detector with rate-of-rise SWIFT Wireless Devices 0 option. W-GATE: LiteSpeed Wireless Gateway H355HT: Fast-response, low-profile heat detector that activates at W-SD355: LiteSpeed intelligent,wireless photo detector. 190°F/88°C. W-H355R: LiteSpeed intelligent wireless rate of rise(135°)heat AD355: Low-profile, intelligent, "Adapt" multi-sensor detector detector. (B350LP base included). WSD355T: Intelligent wireless photo/heat detector. B200S:Programmable,addressable sounder base. W-H355: LiteSpeed intelligent wireless fixed-temperature (135°) B200SR:Addressable sounder base. heat detector. BEAM355: Intelligent beam smoke detector. W-MMF: LiteSpeed Intelligent wireless monitor module. BEAM355S: Intelligent beam smoke detector with integral sensitiv- W-CRF: LiteSpeed Intelligent wireless relay module. ity test. W-BG12LX: LiteSpeed Intelligent wireless pull station. D355PL: InnovairFlex low-flow non-relay duct-detector housing; WAV-RL,WAV-WL,WAV-CRL,WAV-CWL:LiteSpeed Intelligent AV includes SD355R. bases. DNR: InnovairFlex low-flow non-relay duct-detector housing. (Order W-USB: Wireless USB radio/antenna dongle that plugs into the SD355R/SD365R separately.) USB port of a PC running SWIFT Tools. DNRW: InnovairFlex low-flow non-relay duct-detector housing, with SWIFT Tools: Programming and diagnostic utility for the Wireless NEMA-4 rating.Watertight.(Order SD355R/SD365R separately.) Gateway and devices.Available for download from firelite.com. Addressable Modules NOTE: For more information on Compatible Addressable Devices for Addressable Monitor Module for one zone of normally- use with the ES-200X, see the following data sheets (document num- MMF-300: bers): SD365 Series (DF-61010), H365 Series (DF-61011), AD355 open dry-contact initiating devices. Mounts in standard 4.0" (10.16 (DF-52386), BG-12LX(DF-52013), CMF-300-6 (DF-52365), CRF-300-6 cm.)box. Includes plastic cover plate and end-of-line resistor. Mod- (DF-52374), CMF/CRF Series (DF-52130), CP355 (DF-52383), H355 ule may be configured for either a Style B(Class B)or Style D(Class Series (DF-52385), 1300 (DF-52389), ISO-6 (DF-60485), MMF-300 A)IDC. Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- (DF-52356), SD355/SD355T (DF-52384), and SLC Wiring Manual vides two Style B(Class B)only IDCs. (51309). MMF-301: Miniature version of MMF-300. Excludes LED and Style NOTE:Legacy 300 Series detection devices such as the CP300/CP350, D option.Connects with wire pigtails.May mount in device backbox. SD300(T)/SD350(T)and older modules such as the M300,M301,M302, MMF-302:Similar to MMF-300.Addressable Monitor Module for one C304, and BG-10LX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard zone of conventional two-wire detectors. Requires resettable 24 CLIP protocol. Please consult factory for further information on previous VDC power. Refer to the Device Compatibility Document for listed 300 Series devices. compatible devices and quantity limitation. ADDRESSABLE DEVICE ACCESSORIES CMF-300:Addressable Control Module for one Style Y/Z(Class B/ A) zone of supervised polarized Notification Appliances. Mounts End-of-Line Resistor Assembly (R-47K and R-3.9K): The directly to a 4.0" (10.16 cm.) electrical box. NAC option requires 47k ohm assembly supervises the MMF-300, MDF-300, MMF-301, external 24 VDC to power notification appliances. and CMF-300 module circuits. The 3.9k ohm assembly supervises CRF-300:Addressable relay module containing two isolated sets of the MMF-302 module circuit.These resistors are included with each Form-C contacts, which operate as a DPDT switch. Mounts directly module. to a 4.0"(10.16 cm.)box,surface mount using the SMB500. Power Supervision Relay: Supervises the power to 4-wire smoke BG-12LX: Addressable manual pull station with interface module detectors and notification appliances. mounted inside. Wiring Requirements 1300:This module isolates the SLC loop from short circuit conditions While shielded wire is not required, it is recommended that all SLC (required for Style 6 or 7 operation). wiring be twisted-pair to minimize the effects of electrical interfer- ISO-6: Six-fault isolator module. Mount one or two modules in a ence.Refer to the panel manual for wiring details. BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10:Ten-input monitor module. Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6:Six-zone interface module. Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module.Mount one or two modules in a BB-2F cabinet(optional).Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6:Six-relay control module(Form-C relays).Mount one or two modules in a BB-2F cabinet(optional).Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. • . DF-60957:C•7/16/2018—Page 3 of 4 • SYSTEM SPECIFICATIONS System Capacity Temperature and Humidity Ranges • Intelligent Signaling Line Circuits 1 This system meets NFPA requirements for operation at 0—49°C/32 • Addressable device capacity 198 —120°F and at a relative humidity 93%±2%RH(noncondensing)at Programmable software zones 99 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's • standby batteries and the electronic components may be adversely • Annunciators 16 affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in Electrical Specifications an environment with a normal room temperature of 15—27°C/60— AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, 80°F. auto-sensing- no switch required. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. NFPA Standards Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger The ES-200X complies with the following NFPA 72 Fire Alarm Sys- Capacity: 7-18 AH (ES-200X cabinet holds maximum of two 18 AH tems requirements: batteries.) —LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- Communication Loop: Supervised and power-limited. sory). Notification Appliance Circuits: Terminal Block provides connec- —AUXILIARY (Automatic, Manual and Waterflow) (requires tions for four NACs, Style Y(Class B) or Style Z(Class A). Special 4XTMF). Application power. Power-limited, supervised circuitry. Maximum —REMOTE STATION (Automatic, Manual and Waterflow) signaling current per circuit: 2.5 amps special application, 250mA (Where a DACT is not accepted,the alarm,trouble and supervi- regulated. End-of-Line Resistor: 4.7k ohm, Yz watt (P/N 71252 UL sory relays may be connected to UL 864 listed transmitters.For listed)for Style Y(Class B)NAC; system capable of 1.91(0-22 kt2 reverse polarity signaling of alarm and trouble, 4XTMF is ELR range.Refer to the Fire•Lite Device Compatibility Document for required.) listed compatible devices. —PROPRIETARY(Automatic,Manual and Waterflow). Two Programmable Relays and One Fixed Trouble Relay: Con- —CENTRAL STATION (Automatic, Manual and Waterflow, and tact rating:2.0 A @ 30 VDC(resistive), 0.5 A @ 30 VAC(resistive). Sprinkler Supervised). Form-C relays, non-power-limited,non-supervised. —OT, PSDN (Other Technologies, Packet-switched Data Net- work) Cabinet Specifications -IBC 2012,IBC 2009,IBC 2006,IBC 2003,IBC 2000(Seismic). • Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" —CBC 2007(Seismic) (1.82 cm.)deep. Backbox: 19.00"(48.26 cm.)high x 16.65"(42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" Agency Listings and Approvals (55.88 cm.)high x 19.65"(49.91 cm.)wide. The listings and approvals below apply to the basic ES-200X control panel. In some cases, certain modules may not be listed by certain Shipping Specifications approval agencies, or listing may be in process. Consult factory for Weight:26.9 lbs. (12.20 kg.)Dimensions:20.00"(50.80 cm.)high latest listing status. x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. • UL:S624 • FM approved • CSFM:7165-0075:500 - FDNY:COA#6261 NOTE:See DF-60958 for ULC-listed model. AlarmNet®, Fire-Lite®Alarms, SWIFT®,and System Sensor®are registered trademarks of Honeywell International Inc.Microsoft®and Windows®are registered trademarks of the Microsoft Corporation. C2018 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. • This document is not intended to be used for installation purposes. I I t I I + We try to keep our product information up-to-date and accurate. • s�G RT i i r i d We cannot cover all specific applications or anticipate all requirements. •;;;; All specifications are subject to change without notice. MAC I IItYEKIw 1 M a l l I Y $f$1I I i For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. Country of Origin:USA www.firelite.com Page 4 of 4-DF-60057:C•7/16/2018 DF-52310:A2•D-050 FCPS-24FS8 n re uT Ala S • 8-Amp, 24-Volt Power Supply by Honeywell Power Supplies/Accessories General The Fire•Lite FCPS-24FS8(C/E) is a compact, cost-effec- tive, 8-amp remote power supplies with battery charger. The FCPS-24FS8C/E) may be connected to any 12 or 24 volt fire alarm control panel(FACP)or may stand-alone. Primary appli- cations include notification appliance (bell) circuit (NAC) tea. expansion (to support ADA requirements and NAC synchroni- zation)or auxiliary power to support 24 volt system accesso- ries.The FCPS provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either two Class B (Style Y) and Class A (Style Z, with ZNAC-4 option module)or four class B only. Alternately, the four outputs may be configured as any combination of resettable/non-resettable power outputs (optimal for powering four wire smoke detec- tors. The FFCPS-24FS8(C/E)also contains a battery charger capable of charging up to 18.0 Amp hour batteries. FCPS- 24FS8C/E)is ULC-listed. NOTE Unless otherwise specified,the term FCPS-24FS8 used in this document refers to the standard FCPS-24FS8, FCPS- y 24FS8C, FCPS-24FS8Eloon Features • UL-Listed Notification Appliance Circuit(NAC)synchroniza- tion using System Sensor, Wheelock, or Gentex "Com- mander2"appliances. • • Operates as a "sync-follower" or as a "sync-generator" (default). See note on page 2. • Includes integral battery charger capable of charging up to • Contains two fully-isolated input/control circuits - triggered 18 AH batteries.Cabinet capable of housing 7.0 AH batter- from FACP NAC (NAC expander mode)or jumped perma- ies. nently"ON"(stand-alone mode). • Battery charger may be disabled via DIP switch for applica- • Two Class B (Style Y) or Class A (Style Z, with ZNAC-4 tions requiring larger batteries. module)NACs(circuits 1 &3) • Fixed, clamp-type terminal blocks accommodate up to 12 • 8-amp full load output, with 3 amps maximum/circuit, in AWG(3.1mm2)wire. NAC expander mode(UL 864). • 6-amp continuous output in stand-alone mode(UL 1481). Specifications • Compatible with coded inputs;signals passed through. Primary(AC)Power: • Optional power-supervision relay(EOLR-1). • FCPS-24FS8: 120 VAC,60 Hz,3.2A maximum. • In stand-alone mode, output power circuits may be config- • FCPS-24FS8/E: 240 VAC,50 Hz,1.6A maximum. ured as: resettable, (reset line from FACP required), • Wire Size: minimum 014 AWG(2.0mm2)with 600 V insula- non-resettable,or a mix of two and two. tion. • Fully regulated and filtered power output-optimal for pow- Control Input Circuit: ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. • Trigger Input Voltage: 9 to 32 VDC. • Power-limiting technology meets UL power-limiting require- • Trigger Current: 2.0 mA(16-32 V); Per Input: 1.0 mA(9 ments. -16 V). • Form-C normally-closed trouble relay. Trouble Contact Rating: 5 A at 24 VDC. • Fully supervised power supply,battery,and NACs. Auxiliary Power Output: Specific application power 500 mA • Selectable earth fault detection. maximum. • AC trouble report selectable for immediate 2-hour delay. Output Circuits: • Works with virtually any UL 864 fire alarm control which uti- • +24 VDC filtered,regulated. lizes an industry-standard reverse-polarity notification cir- • 3.0 A maximum for any one circuit. cuit(including unfiltered and unregulated bell power). Requires input trigger voltage of 9-32 VDC. • Total continuous current for all outputs(stand-alone mode): •• Self-contained in compact,locking cabinet-15"H x 14.5W —FCPS-24FS8: 6.0 A maximum. x 2.75"D(cm:38.1 H x 36.83W x 6.985D). • Total short-term current for all outputs(NAC expander mode): • —FCPS-24FS8: 8.0 A maximum. DF-52310 A2•5/17/13—Page 1 of 4 Secondary Power(Battery)Charging Circuit: Agency Listings and Approvals • • Supports lead-acid batteries only.• Float-charge voltage: 27.6 VDC. These listings and approvals apply to the modules specified in this document. In some cases,certain modules or applications • Maximum current charge: 250 mA. may not be listed by certain approval agencies, or listing may Maximum battery capacity: 7.0 AH. be in process. Consult factory for latest listing status. • • UL Listed: S2424 Applications • ULC Listed:S2424 • Example 1: Expand notification appliance power an additional CSFM Approved: 7315-0075:206 8.0 A. Use up to four Class B(Style Y)outputs or four Class A • MEA:219-02E (Style Z)outputs(using ZNAC-4).For example,the FACP noti- fication appliance circuits will activate the FOPS when reverse- Ordering Information polarity activation occurs.Trouble conditions on the FCPS are FCPS-24FS8: 6.0 A, 120 VAC remote charger power supply. sensed by the FACP through the notification appliance circuit. Includes main printed circuit board, transformers, enclosure Example 2: Use the FCPS to expand auxiliary regulated 24- (15"H x 14.5"W x 2.75"D[cm:38.1H x 36.83W x 6.985D]),and volt system power up to 6.0 A. Both resettable and non-reset- installation instructions. table power options are available. Resettable outputs are cre- ated by connecting the resettable output from the FACP to one FCPS-24FS8 is ULC-listed. or both of the FCPS inputs. FCPS-24FS8E: 6.0 A,240 VAC remote charger power supply. Example 3: Use addressable control modules to activate the Includes main printed circuit board, transformers, enclosure FCPS instead of activating it through the FACP notification (15"H x 14.5"W x 2.75"D[cm:38.1H x 36.83W x 6.985D]),and appliance circuits. This typically allows for mounting the FCPS installation instructions. at greater distances" away from the FACP while expanding ZNAC-4: Class A(Style Y)NAC option module. system architecture in various applications. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire For example, an addressable control module is used to acti- smoke detector power. vate the FCPS, and an addressable monitor module is used to BAT-1270: Battery, 12-volt,7.0 AH(two required). sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control PS-1270: Battery, 12-volt,7.0 AH(two required). module. 90286: Optional module mounting kit, is required to Install an "NOTE:Addressable FACPs are capable of locating control and addressable module on the power supply main circuit board. monitor modules at distances of up to 10,000 feet(3,046 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-24FS8 can track(i.e."follow")the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24FS8 is configured (via DIP switch settings) as a"sync follower,"the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input ter- minal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24FS8 is configured(via DIP switch settings) as a"sync generator:'the FCPS's sync input terminals are not used. Rather,the FCPS is the originator of the strobe synchro- nization pulses on the FCPS's NAC outputs. In "sync genera- tor" mode, the sync type (System Sensor, Wheelock, or Gentex)is selectable via DIP switch settings. Standards and Codes The FCPS-24FS8 complies with the following standards: • NFPA 72 National Fire Alarm Code. • UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). • UL 1481 Power Supplies for Fire Alarm Systems. • Page 2 of 4—DF-52310:A2•5/17/13 • NOTE:All NAC outputs can be converted to Style Z with Style Y NAC or ZNAC-4 option module. FCPS Door Holder Trouble Power Style Y NAC Style Y NAC Style Y NAC Contact Output#4 Output#3 Output#2 Output#1 Output 24 VDC 0. ► Specific Application Power AC NAC Control Power ,• 1111 Input#2 INPUT/OUTPUT (from FRCP) FUNCTIONS are programmable by NAC Control SW1 DIP switch settings 111111MII Input#1 (from FACP) +MI Sync Input FCPS • Battery Charger Simplified Block Diagram • DF-52310:A2•5/1 7/13—Page 3 of 4 • ma -ua v N n U a.t3 c « c 3i O O 41 m °o E a a a E .0 a • 5 w 0 . c .7,„ m 2 Y ^'ice u U n .2 0 ° o • E. c 'a2 q R ° O a m a U a 02 7 2" C U a G C c ¢�ti 9 z 'O �y -l' K 0 0 -5 O O T T y1 O `° `o o vi E O ••2$o Ng 035 < a V O o o O V to co �SZ z z O m o= 1 2 5's m° 2 E 0' 1 I + I t Z c Fug -c7o_- -a0 -.o_ Oa n m O F7 ~m a® ,r � , a IN N I R1 - 1 - 1 c m m n a q _ M in a 0 N .- r - r N ' O c] O o a 1 Ong E 13 OO m "La °o' 41 ZZ N°I I k L� 1-.. E c, 1 mm zz 55 + I m ya`o Oo vv ~ y x UO' 55 O g ¢¢ 00 �LLE ZZ 88 bV>._ QQ 0 z ZZ EZa n J 5 e. e d 81.i .° N g x E-,.51 ;a 3 J 1 i404 __Om_pQ m OL6L 0 !/ ��� N`��a F 10 'l N 1 � v t ll� °`mom; siV°mQ NN IL WQU'mZU ii L y#k m -. z`v d m d o . E€ € 0 m p t. ZPi II J'`i.9 - f9 W Q Q 3 N` N ff 11 d p J c, O m aco c mm yd> e ' 0 4r� ..mod it - + =4= e �� m a ❑ m A0 c <Ca r'm LLm — �icO '~ c 0 coo 0 0 OOP G a __._ e O Board Layout System Sensor© and FireLitee Alarms are registered trademarks of Honeywell International Inc. I»2013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document Is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. .r.r We try to keep our product information up-to-date and accurate. o c FIT I F t c to We cannot cover all specific applications or anticipate all requirements. ifiiiiiiiiiimmi� • 6YSI Iltll L I a S I III I ErS'1I►LIIt I All specifications are subject to change without notice. ' Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 4 of 4—DF-52310.A2•5/17/13 � N �� - � 0� ����� CELLULAR ALARM Np ~ �� � " —= C0yNMUNI [` AT [lR U �� � �� � " ~~ ~ ° � �� [7 iT � �� � TVV [l [� �( � TE U �� 0 A R �� ' ° ' ` � ' � ' ` � ' , . = . ` ^ ^ � kMETEK COMMERCIAL FIRE PRODUCT FEATURES + Certified for use onVerizon'sLTE network for sunset-free | installations. Ji- Meets ULR64 requirements for sole, primary or backup path communications. � Minimizes false alarms byproviding dual paths for so|f^t*sts. | '|| The Tu|guardTG~7FSLTE^Vis the ideal cellular alarm communications � solution for commercial fire systems. The TG^7FSCDMAtransmits ` We '� � alarm signals hnmthe fire panel over the digital cellular network tnthe ` designated monitoring station. C0mp|iantvviththe2Ol9andeadiereditionsofNFPATItheTG~7FS LTE4/ can serve as the sole communication path for the fire alarm system. |t replaces all nf the |and|ines currently dedicated hnthe master control unit. On average, cellular monitoring costs the end user significantly less than adedicated |and|ine. For each |and|inereplaced with aTG~7FS LTE4< the monthly communications bill decreases. By being able to signal failures tu the central station within sixty minutes ufan outage, the T6'7FSLTE^V can b* installed as the sole path for commercial fire installations. For existing installations, all |and|ines can be swapped for a single T6~7FSLTE^V because cf the new five or sixty minute supervision modes. The TG~7FSLTE`V can also be installed asa backup path and upgraded to sole path ata later date. A. pf ' ' ' TG - 7FS CELLULAR ALARM �a`'` COMMUNICATOR TELGUARD LTE —V FOR LIE NETWORKS %METEK e oi» I r d.,35!£ 3 INIiF Id„ it IO I I Illi ( ,„, S.TM '.an: PI rm l`�.n`I Ra/F`. ' ..nn I,lrt m.. ' x �kaS+*;"'' Z SzA :;: r , Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for 41arft* superior in-building penetration. " _ „ •'' Telguard products are easy to install, economical, and UL Listed. ' ':-, Accessories 21 • ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. • HGD-0: High gain directional antenna. �.. _ • EXD-0: External antenna. ' �' '77`i5 ' � UL Listings R ' ,4 = Commercial Fire Commercial Burglary Residential 1 i_•� 'l , 864 • Control units& 365 • Police Station 985 • Household fire � .. {' :€...as accessories for fire connected burglar warning Systems '� alarm systems alarm units and 1023 • Household burglar : ,,,gtfitiii*Sht A systems alarm systems • ° 1610 •Central station burglar ,y'. 't; .' °n alarm units; "=* ili # • Line security servcies •a`d-^ � ;;���,,� � For the most current product spec Fr atlons and UL Latings vlslt wwwTel9uard.com. i �A(: € S "as. v �"&:dy ` SECURITY "'""""' ;° rs+l .s`>r , SIGNALING ';:zpv,' iii _- // '`l 1 (f ,'.,; ✓ E-11 HITY verizon j!/ ````���771A:SOLIATION" network cmnfiea it"..,:::.- :i G,.. --„,, s'". e u m, LISTED S . ,4 fnrwranonn� Telguard,a Division of Telular Corporation•3225 Cumberland Blvd SE•Suite 300•Atlanta,GA 30339•USA 800.229.2326 I telguard.com•Copyright r 2019 Telguard,a Business Unit of AMETEK.Inc.•All Rights Reserved to • H111.1„ ' PROD' 'CT,S, Iii\j C. if(lil(,li, i r t r. tN i il , ','�" DocBoxEs 1' tIt. 1.1' ftil "" j; f+ i9 1;, K._f„ri-' ,"� jj Full 1'(7 } }'t";-' . `P:eu7,, ,, ,_ " 7`�`,i5' Ijl � ,. . �.. r The door can be left blank, or ______________________ � " one of the three labels may be ....:;.- used. q� .............fS 69Yx X BW-DocBox :, BW-DocBox(15"Wx 13"Hx4"D) n.1 ? • ULlc-UL Listed ` • THREE labels:ip "Fire Alarm Documents" � � "As Built Permits" = s ' "Test and Maintenance Documents" r ' • An adjustable bungee allows you to fit various sizes of hinders, ,: I{, ", documents, smoke-cans, etc. IU.,€hI ' I u • A door bracket holds two CDs, three { s11, i, sets of keys and more documents • A cam lock with two keys ,., ; g 40ABW DocBox2 (11"Wx 15"Hx 4"D) ; Smaller model without the door bracket. BW-DocBox2 ? Other colors,graphic screening, Don't see the enclosure you need. Call or e-mail us and we'll he happy to help! and customization are available for quantities of 25 or more. W •-...__ I7 - _ - ,� .,..-,.,,.....,. Indoor & Outdoor Electrical Enclosures I Drive-Alert Vehicle Detection & Asset Protection Systems I Custom Fabrication 800-473-0213 — info@mierproducts.com — www.rnierproducts.com DF-52013:D•E-100 BG-12LX 1" u e Alarms Addressable Manual Pull Station by Honeywell Addressable Devices General The Fire Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire Lite's addressable fire alarm control panels (FACPs) F R Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station.This leads fire personnel quickly to the location of the alarm. Features PUSti IN PULL DOWN • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station,flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop(accepts up to 12 AWGl3.25 mm'wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- o gang,double-gang,or 4"(10.16 cm)square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. usually needed for semi-flush mounting with 4" (10.16 cm)or • Attractive shape and textured finish. double-gang boxes(not with single-gang boxes). • Key reset. Operation • Includes Braille text on station handle. Optional trim ring(BG12TR). Pushing in,then pulling down on the handle causes it to latch • in the down/activated position. Once latched, the word"ACTT- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station.To reset the station,simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 —159 with Breakaway Tab removed for MS-9600 Series, 1— • Shipping Weight:9.6 oz.(272.15 g) 99 and MS-92000DLS, 1 —50 for MS-9050UD). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current:375 NA. Specifications • Maximum SLC alarm current:5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range:32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity: 10%to 93%(noncondensing) designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated sta- • For use indoors in a dry location tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The BG-12LX will mount semi-flush into a single-gang,double- ing instructions provided on the cover. The word FIRE shall gang,or standard 4"(10.16 cm)square electrical outlet box,or appear on the front of the stations in white letters, 1.00 inches will surface mount to the model SB-10 or SB-I/O surface back- (2.54 cm) or larger. Stations shall be suitable for surface • box. If the BG-12LX is being semi-flush mounted, then the mounting on matching backbox SB-10 or SB-I/O;or semi-flush optional trim ring (BG12TR) may be used. The BG12TR is mounting on a standard single-gang, double-gang, or 4"(10.16 cm) square electrical box, and shall be installed OF-52013.D•4/13/2012—Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations • shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) SB-10:Surface backbox;metal. SB-I/O:Surface backbox;plastic. BG12TR:Optional trim ring. 17003:Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • UL/ULC Listed: S711 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E. • CSFM:7150-0075:0184. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. r FireLite®Alarms®is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. II r I I 1 We try to keep our product information up-to-date and accurate. s=c a T c r c a We cannot cover all specific applications or anticipate all requirements. BRIO EMI tY'/Kfw All specifications are subject to change without notice. * LLltf 61$11110 Made in the U.S.A. For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—DF-52013:D•4/13/2012 DF-61010:A SD365(A) Series Fire lireAlarms . Addressable Photoelectric Detectors by Honeywell General The Fire-Lite SD365(A), SD365T(A), and SD365R(A) Series addressable plug-in photoelectric smoke detectors are designed for both performance and aesthetics.A new modern,sleek, contempo- rary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. Exclusively for use with Fire-Lite's addressable fire alarm control panels,the SD365(A)Series point ID capability allows each detec- tor's address to be set with rotary,decimal address switches,provid- ing exact detector location for emergency personnel to quickly locate � 1 , G j1 a fire during its early stages,potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local,visible sensor indication. The SD365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the SD365T(A)and a remote test capable detec- tor on the SD365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features SD365 SLC LOOP • Two-wire loop connection. Installation • Unit uses base for wiring. SD365(A)series plug-in detectors use a detachable mounting base to simplify installation,service and maintenance. . ADDRESSING Mount base (all base types) on an electrical backbox which is at • Addressable by device. least 1.5"(3.81 cm)deep. For a chart of compatible junction boxes, • Rotary, decimal addressing: Please refer to the Fire-Lite panel see DF-60059. manuals for device capacity. NOTE:Because of the inherent supervision provided by the SLC loop, ARCHITECTURE end-of-line resistors are not required. Wiring `T-taps"or branches are permitted for Style 4 (Class B) wiring. SD365R(A) mounts in a • New modern profile for improved aesthetics. D355PL(A)or DNR(A)/DNRW duct detector housing. • Unique single-source design to respond quickly and dependably to a broad range of fires. Operation • Integral communications and built-in type identification. Each SD365(A)Series detector uses one possible addresses on the • Built-in tamper-resistant feature. Fire-lite Signaling Line Circuit (SLC). It responds to regular polls • Removable cover and insect-resistant screen for simple field from the system and reports its type and status. cleaning. Detector Sensitivity Test OPERATION Each detector can have its sensitivity tested(required per NFPA 72, • Designed to meet UL 268 7th Edition. Chapter 14 on Inspection, Testing and Maintenance)when installed/ • Factory preset at 1.5%nominal sensitivity for panel alarm thresh- connected to an ES-50X or ES-200X addressable fire alarm control old level. panel. The results of the sensitivity test can be printed off the for • Visible LED "blinks"when the unit is addressed (communicating record keeping. with the fire panel)and latches on in alarm. • Low standby current. Specification MECHANICALS Voltage range: 15—32 VDC(peak). • Sealed against back pressure. Standby current:200 pA @ 24 VDC. • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) Max current:4.5 mA @ 24 VDC(latched"ON"). octagonal box, or 4.0" (10.16 cm) square electrical box (with or Air velocity:4,000 ft./min.(20 m/sec.)maximum. without a mud ring-not included). Sensitivity:UL Applications:0.5%to 4.0%per foot obscuration OPTIONS Size:2.0"(5.3 cm)high;base determines diameter. • Remote LED output connection, RA100Z. —B300-6:6.1"(15.6 cm)diameter. . —B501:4"(10.2 cm)diameter. For a complete list of detector bases see DN-60981. Shipping weight:3.4 oz.(95 g). DF-61010:A•4/2118—Page 1 of 3 Operating temperature range: B224BI-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216 • SD365(A):0°C to 50°C(32°F to 122°F); Pending) • • SD365T(A):0°C to 38°C(32°F to 100°F). B224BIA-WH:White,isolator detector base,ULC listing. • SD365R(A):installed in a DNR(A)/DNRW-20°C to 70°C (-4°F to B224BIA-IV:Ivory isolator detector base,ULC listing. 158°F). B200S-WH:White, Intelligent addressable sounder base capable of Relative humidity: 10%-93%,non-condensing. producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Listings Uses FlashScan protocol.(CSFM:7300-1653:0213 Pending) Listings and approvals below apply to the SD365 Series detectors. B200S-IV: Ivory, Intelligent addressable sounder base capable of In some cases, certain detectors may not be listed by certain producing sound output in high or low volume with ANSI Temporal 3, approval agencies, or listing may be in process. Consult factory for ANSI Temporal 4,continuous tone,marching tone,and custom tone. latest listing status. Uses FlashScan protocol. (CSFM:7300-1653:0213 Pending) • UL/ULC Listed:S1059 B200SA-WH:Same as B200S-WH,ULC listing. • CSFM:7272-0075-0502 B200SA-IV:Same as B200S-IV,ULC listing. • FM Approved B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Product Line Information Series detector applications. NOTE:Detectors must be mounted to one of the Intelligent Bases listed B200SCOA-IV: Ivory Intelligent, programmable sounder base in below. English/French (required in Canada for ULC applications with CO Series detector applications,ULC listing. NOTE:"IV"suffix indicates LiteSpeed® and CLIP device. NOTE:"A"suffix indicates Canadian version. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- SD365(A):White,Addressable photoelectric detector; B300-6 base 10% with a square wave or its equivalent; designed to meet the included.LiteSpeed only. NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 SD365(A)-IV: Ivory, Addressable photoelectric detector; B300-6 Pending) base included. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable SD365T(A): White, Same as SD365 but with thermal element; sounder base. Produces a fundamental frequency of 520 Hz +/- B300-6 base included.LiteSpeed only. 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 SD365T(A)-IV: Ivory, Same as SD365 but with thermal element; Pending) B300-6 base included. B200SR-WH: White, Intelligent sounder base capable of producing SD365R(A): White, Remote test capable addressable photoelectric sound output with ANSI Temporal 3 or continuous tone. Intended for ledetector for use with DNR(A)/DNRW.LiteSpeed only. retrofit applications. (CSFM:7300-1653:0213 Pending) SD365R(A)-IV: Ivory, Remote test capable addressable photoelec- B200SR-IV: Ivory, Intelligent sounder base capable of producing tric detector;for use with DNR(A)/DNRW. sound output with ANSI Temporal 3 or continuous tone. Intended for INTELLIGENT BASES retrofit applications.(CSFM:7300-1653:0213 Pending) NOTE:For details on intelligent bases,see DN-60981. B200SRA-WH:Same as B200SR-WH with, ULC listing. B300-6:White,6"base,standard flanged low-profile mounting base. B200SRA-IV:Same as B200SR-IV in Ivory color,ULC listing. (CSFM:7300-1653:0109 Pending) B200SR-LF-WH: White, Low Frequency Intelligent, programmable B300-6-IV: Ivory,6" base, standard flanged low-profile mounting sounder base. Produces a fundamental frequency of 520 Hz +/- base.(CSFM:7300-1653:0109 Pending) 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- B300A-6:Same as B300-6,ULC listed. tions.(CSFM:7300-1653:0238 Pending) B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable ULC listed. sounder base. Produces a fundamental frequency of 520 Hz +/- B300.6-BP: Bulk pack of B300-6,package contains 10 10% with a square wave or its equivalent; designed to meet the 6501-WHITE: White, 4" standard European flangeless mounting NFPA 72 sleeping space requirement. Intended for retrofit applica- base. UL/ULC listed.(CSFM:7300-1653:0109 Pending) tions.(CSFM 7300-1653:0238 Pending) B501-BL: Black, 4" standard European flangeless mounting base. MOUNTING KITS AND ACCESSORIES UL/ULC listed.(CSFM:7300-1653:0109 Pending) TR300:White,replacement flange for B210LP(A)base. B501-IV: Ivory color, 4" standard European flangeless mounting TR300-IV: Ivory,replacement flange for B210LP(A)base. base. UL/ULC listed.(CSFM:7300-1653:0109 Pending) RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Mounts to a B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. U.S. single-gang electrical box. For use with B501(A) and B300- B224RB-WH:White,relay base.(CSFM: 7300-1653:0216 Pending) 6(A). B224RB-IV: Ivory,relay base.(CSFM:7300-1653:0216 Pending) M02-04-00:Test magnet. B224RBA-WH:White,relay base,ULC listing. M02-09-00:Test magnet with telescoping handle. B224RBA-IV: Ivory,relay base,ULC listing. CK300:Color Kit(includes cover and trim ring),white, 10-pack. B224BI-WH: White, isolator detector base. (CSFM: 7300- CK300-IV:Color Kit(includes cover and trim ring), ivory, 10-pack. . 1653:0216 Pending) CK300-BL:Color Kit(includes cover and trim ring),black,10-pack. OF-61010:A•4/4/18—Page 2 of 3 • • FireLite®Alarms is a registered trademark of Honeywell International Inc. ©2018 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. Iso We cannot cover all specific applications or anticipate all requirements. ® All specifications are subject to change without notice. MIMIC14I1K�l For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. Illlllr 64SIE�S www.firelite.com Page 3 of 3—DF-61010:A•4/4/18 DF-52121:E•E-325 MMF-300(A) Series, • MDF-300 Fire-LITGALarMS Addressable Monitor Modules by Honeywell Addressable Devices General Four different monitor modules are available for Fire•Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input " devices,such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF 302(A)). •.., 4 MMF-300(A)is a standard-sized module(typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A)is a miniature monitor module a mere 1.3"(3.302 cm)H x 2.75"(6.985 cm)W x 0.65"(1.651 cm)D that super- 41x vises a Style B(Class B)circuit of dry-contact input devices.Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. " MMF-302(A)is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D(Class A)or Style B(Class B)circuit. MDF-300(A)is a standard-sized dual monitor module used to MMF-300(A)(Type H) monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two supervisory indication at the control panel. Monitored circuit separate, consecutive addresses in intelligent, two-wire sys- may be wired as an NFPA Style B(Class B)or Style D(Class tems. A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor • LiteSpeedT"' is a communication protocol developed by (provided)terminates the Style B circuit.No resistor is required Fire•Lite Engineering that greatly increases the speed of com- for supervision of the Style D circuit. munication between analog intelligent devices. Intelligent MMF•300(A)OPERATION devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU Each MMF-300(A) uses one of the available module stops the group poll and concentrates on single points. The addresses on an SLC loop. It responds to regular polls from net effect is response speed greater than five times that of the control panel and reports its type and the status(open/nor- other communication protocols. mal/short)of its Initiating Device Circuit(IDC).A flashing LED indicates that the module is in communication with the control MMF-300(A) Monitor Module panel. The LED latches steady on alarm (subject to current limitations on the loop). • Built-in type identification automatically identifies this device as a monitor module to the control panel. MMF-300(A)SPECIFICATIONS • Powered directly by two-wire SLC loop. No additional Nominal operating voltage: 15 to 32 VDC. power required. Maximum current draw:5.0 mA(LED on). • High noise(EMF/RFI)immunity. Average operating current: 375 pA (LED flashing), 1 com- • SEMS screws with clamping plates for ease of wiring. munication every 5 seconds,47k EOL. • Direct-dial entry of address: 01 — 159 on MS-9600 series Maximum IDC wiring resistance: 1500 Ohms. panels,01 —99 on other compatible systems. • LED flashes during normal operation and latches on steady Maximum IDC Voltage: 11 Volts. to indicate alarm. EOL resistance:47K Ohms. The MMF-300(A)Monitor Module is intended for use in intelli- Temperature range:32°F to 120°F(0°C to 49°C). gent,two-wire systems, where the individual address of each Humidity range: 10%to 93%noncondensing. module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Device Circuit (IOC)for normally-open-contact fire alarm and 125" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x supervisory devices. The module has a panel-controlled LED 2.125"(5.398 cm)deep box. indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-301(A) Mini Monitor Module MMF-300(A)APPLICATIONS • Built-in type identification automatically identifies this device Use to monitor a zone of four-wire smoke detectors, manual as a monitor module to the panel. • fire alarm pull stations, waterflow devices, or other normally- • Powered directly by two-wire SLC loop. No additional open dry-contact alarm activation devices. May also be used power required. to monitor normally-open supervisory devices with special • High noise(EMF/RFI)immunity. DF-52121:E•07/30/2015—Page 1 of 4 • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • • Direct-dial entry of address: 01 159 on MS-9600 series source. panels,01 —99 on other compatible systems • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. 3 1415 0 1 ' ADDRESS •0 1 • Direct-dial entry entry of address: 01 — 159 on MS-9600 13�f�„'\2 I _ \2 series panels,01 —99 on other compatible systems. 12 lip j3�1 LOOP �/� ���3 • LED flashes during normal operation. ' 12(/ J,/)S ,&;_/�j''4 • LED latches steady to indicate alarm on command from /5 control panel. 9'$-.7-6 ! !.._ 9 8--7 6 TENS ONES The MMF-302(A)Interface Module is intended for use in intelli- f-,j 11 gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This E module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status O . p v (normal, open, or alarm) of one full zone of conventional -.i —I W„ Q detectors back to the control panel. All two-wire detectors } m being monitored must be UL compatible with the module.The ',I MMF-302(A) can be used to replace M302(A) modules in existing systems. rj � MMF-302(A)APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke The MMF-301(A) Mini Monitor Module can be installed in a detectors. The monitored circuit may be wired as an NFPA single-gang junction directly behind the monitored unit. Its Style B(Class B)or Style D(Class A) Initiating Device Circuit. small size and light weight allow it to be installed without rigid A 3.9 K Ohm End-of-Line Resistor (provided) terminates the mounting. The MMF-301(A) is intended for use in intelligent, end of the Style B or D (class B or A) circuit(maximum IDC two-wire systems where the individual address of each module loop resistance is 25 Ohms). Install ELR across terminals 8 is selected using rotary switches. It provides a two-wire initiat- and 9 for Style D application. ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A)can be used to replace M301(A)modules in MMF-302(A)OPERATION existing systems. Each MMF-302(A) uses one of the available module MMF-301(A)APPLICATIONS addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status(open/nor- Use to monitor a single device or a zone of four-wire smoke mat/short)of its Initiating Device Circuit(IDC).A flashing LED• detectors, manual fire alarm pull stations, waterflow devices, indicates that the module is in communication with the control or other normally-open dry-contact devices. May also be used panel. The LED latches steady on alarm (subject to current to monitor normally-open supervisory devices with special limitations on the loop). supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B(Class B)Initiating Device MMF-302(A)SPECIFICATIONS Circuit.A 47K Ohm End-of-Line Resistor(provided)terminates Nominal operating voltage: 15 to 32 VDC. the circuit. Maximum current draw:5.1 mA(LED on). MMF-301(A)OPERATION Maximum IDC wiring resistance:25 Ohms. Each MMF-301(A) uses one of the available module Average operating current:270 pA, 1 communication and 1 addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3.9k eol. the control panel and reports its type and the status(open/nor- mal/short)of its Initiating Device Circuit(IDC). EOL resistance:3.9K Ohms. MMF-301(A)SPECIFICATIONS External supply voltage(between Terminals T10 and T11): • Nominal operating voltage:15 to 32 VDC. DC voltage:24 volts power limited. • Ripple voltage:0.1 Vrms maximum. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC • Current:90 mA per module maximum. Shorted). Temperature range:32°F to 120°F(0°C to 49°C). Maximum IDC wiring resistance: 1500 Ohms. Humidity range: 10%to 93%noncondensing. Maximum IOC Voltage: 11 Volts. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC Current:450 pA. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. EOL resistance:47K Ohms. Temperature range:32°F to 120°F(0°C to 49°C). MDF-300(A) Dual Monitor Module Humidity range: 10%to 93%noncondensing. The MDF-300(A) Dual Monitor Module is intended for use in Dimensions: 1.3" (3.302 cm)high x 2.75" (6.985 cm)wide x intelligent, two-wire systems. It provides two independent two- 0.65"(1.651 cm)deep. wire initiating device circuits(IDCs)at two separate,consecutive addresses. It is capable of monitoring normally open contact fire Wire length:6"(15.24 cm)minimum. alarm and supervisory devices.The module has a single panel- controlled LED. • MMF-302(A) Interface Module • Supports compatible two-wire smoke detectors. Page 2 of 4—DF-52121:E•07/30/2015 NOTE: The MDF-300(A)provides two Style B (Class B) IDC cir- MDF-300(A): Monitor module, dual,two independent Class B cults ONLY. Style D(Class A) IDC circuits are NOT supported in circuits. • any application. SMB500:Optional surface-mount backbox. MDF-300(A)SPECIFICATIONS NOTE: See installation instructions and refer to the SLC tiring Normal operating voltage range: 15 to 32 VDC. Manual,PN 51309. Maximum current draw:6.4 mA(LED on). Architects'/Engineers' Specifications Average operating current:750 pA(LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Specifications of these devices and all FireLite products are available from FireLite. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:240 pA EOL resistance:47K Ohms. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. MDF-300(A)AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE: "Ones"addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. • Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4"(10.16 cm)square,2.125"(5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A)module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S2424. • ULC:S2424. • FM Approved. • CSFM:7300-0075:0185. • MEA:72-01-E. Product Line Information NOTE:"A"suffix indicates ULC-listed model. MMF-300(A):Monitor module. MMF-301(A):Monitor module,miniature. • MMF-302(A):Monitor module,two-wire detectors. • •MDF 52'21 E•07/30/2015—Page 3 of 4 • • Fire.Lite®is a registered trademark and LiteSpeed""and FireWatchry are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. II II I 1 We try to keep our product information up-to-date and accurate. o c rt r i c t c to We cannot cover all specific applications or anticipate all requirements. • eMltw WICM� 14Ltltf 6 All specifications are subject to change without notice. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 4 of 4—D F-52121:E•07/30/2015 df-52130:B2•E-350 CMF-300(A) 401 Fireitime Alar'm Control Module } by Honeywell � �� ��� - ^-- i��11. " a �• Ij PEt l��ir.l %r>Q- "ate e ,� General The CMF-300(A) Addressable Control Module provides Fire•Lite intelligent control panels a circuit for Notification Appliances (horns, strobes, etc.). Addressability allows the CMF-300(A)to be activated through panel programming,on a select(zone or area of coverage)basis. LiteSpeedT", is a communication protocol developed by r n Fire•Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. 1,4 Features o" • Built-in type identification automatically identifies these devices to the control panel. • Internal circuitry powered directly by two-wire SLC loop. The CMF-300(A) module requires power (for horns, CMF-300(A) strobes,etc.). • Integral LED "blinks" green each time a communication is received from the control panel and turns on steady red external power supply is always relay-isolated from the corn- when activated. munication loop so that a trouble condition on the external • • High noise immunity(EMF/RFI). power supply will never interfere with the rest of the system. • The CMF-300(A) may be used to switch 24-volt NAC Rotary switches set a unique address for each module. The power. address may be set before or after mounting. The built-in • Wide viewing angle of LED. TYPE CODE (not settable)will Identify the module to the con- • SEMS screws with clamping plates for wiring ease. trol panel,so as to differentiate between a module and a sen- sor address. • Direct-dial entry of address: 01— 159 for MS-9600 series panels,01 —99 on MS-92000DLS and MS-9050UD. Specifications Applications Normal operating voltage: 15 to 32 VDC. The CMF-300(A) is used to switch 24 VDC audible/visual Maximum SLC current draw:6.5 mA(LED on). power. Average operating current: 350 pA direct poll (CLIP mode), 375 pA group pot(LiteSpeed mode)with LED flashing. Construction External supply voltage:maximum 80 volts(RMS or DC). • The face plate is made of off-white heat-resistant plastic. Drain on external supply: 2 mA maximum (using internal • Controls include two rotary switches for direct-dial entry of EOL relay). address setting. EOL resistance:47K ohms. • The CMF-300(A)is configured for a single Class B(Style Y) Temperature range:32°F to 120°F(0°C to 49°C). or Class A(Style Z)Notification Appliance Circuit. Humidity range: 10%to 93%non-condensing. Operation Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Each CMF-300(A) uses one of the module addresses on a 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x SLC loop. It responds to regular polls from the control panel 2.125"(5.398 cm)deep box. and reports its type and status, Including the open/normal/ short status of its Notification Appliance Circuit (NAC). The Agency Listings and Approvals LED blinks with each poll received. On command, it activates In some cases, certain modules may not be listed by certain its internal relay. The CMF-300(A) supervises Class B (Style approval agencies, or listing may be in process. Consult fac- Y)or Class A(Style Z)notification or control circuits. tory for latest listing status. Upon code command from the panel,the CMF-300(A) will dis- • ULC:S2424 connect the supervision and connect the external power sup- . ply in the proper polarity across the load device. The Product Line Information disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The CMF-300: Intelligent addressable control module. df-52130:132.4/20/10—Page 1 of 2 CMF-300A: Canadian Intelligent addressable control • module. SMB500:Optional surface-mount backbox. CB500: Optional control module barrier, required by UL for separating power-limited and non-power-limited wiring in the same junction box as CMF-300(A). NOTE: For installation instructions, see document 156-1189-009 and refer to the SLC Wiring Manual, document 51309. The CRF- 300(A)relay module,previously on this data sheet, is now on DF- 60379. • LiteSpeed"'is a trademark and Fire•Lite®Alarms is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. II I I I 1 We try to keep our product information up-to-date and accurate. Ito We cannot cover all specific applications or anticipate all requirements. • HIM MIK I IIIMML1ME All specifications are subject to change without notice. }.LLIrT 6T51 Eft Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—df-52130:B2.4/20/10 df-60379:Al •E-400 . CRF-300(A) FireuTe-ALarms Relay Module by Honeywell Addressable Devices General The CRF-300(A)Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming,on a select basis. K» LiteSpeed is a communication protocol developed by lip ° Fire•Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent ° s devices communicate in a grouped fashion. If one of the •;: devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The a as net effect is response speed greater than five times that of other designs. Features • Built-in type identification automatically identifies these devices to the control panel. • Internal circuitry and relay powered directly by two-wire ® �,t SLC loop. • Integral LED "blinks" green each time a communication is CRF-300(A) received from the control panel and turns on in steady red when activated. • High noise immunity(EMF/RFI). • • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. Specifications • Direct-dial entry of address:01-159 for MS-9600(A)series Normal operating voltage: 15 to 32 VDC. panels,01 —99 on MS-92000DLS(A)and MS-9050UD(A). Maximum SLC current draw: 6.5 mA(LED on). Applications Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll(LiteSpeed mode)with LED flashing. The CRF-300(A) may be programmed to operate dry contacts EOL resistance: not used. for door holders,Air Handling Unit shutdown,etc.,and to reset four-wire smoke detector power. Temperature range: 32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%non-condensing. Construction Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x • The face plate is made of off-white heat-resistant plastic. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x • Controls include two rotary switches for direct-dial entry of 2.125" (5.398 mm)deep box. address setting. • The CRF-300(A)is configured for a single Class B(Style Y) Relay Contact Ratings or Class A(Style Z)Notification Appliance Circuit. Maximum Current • The CRF-300(A) provides two Form-C dry contacts that Load Description Application Voltage Rating switch together. Resistive Non-Coded 30 VDC 3.0 A Operation Resistive Coded 30 VDC 2.0 A Each CRF-300(A)uses one of the addresses on a SLC loop. It Resistive Non-Coded 110 VDC 0.9 A responds to regular polls from the control panel and reports its Resistive Non-Coded 125 VAC 0.9 A type and status, including the open/normal/short status of its Notification Appliance Circuit(NAC). The LED blinks with each Inductive(L/R=5ms) Coded 30 VDC 0.5 A poll received.On command, it activates its internal relay. Inductive(L/R=2ms) Coded 30 VDC 1.0 A NOTE:Open/short supervision is suspended with the CRF-300. Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE(not sellable)will identify the module to the con- trol panel, so as to differentiate between a control module and a relay module. df-60379:A1•08/04/09—Page 1 of 2 Agency Listings and Approvals • In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S2424 • ULC:S2424 • FM approved • CSFM:7300-0075:185 • MEA:72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. : Intelligent addressable relay module, ULC listed model. SMB500:Optional surface-mount backbox. NOTE: For installation instructions, see document 156-1190-005 and refer to the SLC Wiring Manual,document 51309. • LiteSpeed""is a trademark and Fire•Lite®Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. :;;rtrrr II III 1 We try to keep our product information up-to-date and accurate. C G R T i F 1 i O We cannot cover all specific applications or anticipate all requirements. • tAt••R r,UYlV/l E t All specifications are subject to change without notice. }tfillf7 6f$I tt Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—df-60379:Al•08/04/09 1 Ivp^ • Outdoor Selectable- a Output Horns, Strobes, and Horn Strobes for Wall Applications SPECTRMert SpectrAlertg Advance outdoor audible visible products e'er Ire INI are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns. • Weatherproof per NEMA 4X.IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL.1638(strobe)and UL 464(horn) devices.SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement, including indoor,outdoor.wet,and dry applications in legacy SpectrAlert products temperatures from-40°F to 151°F. • Field-selectable candela settings, 15. 15/75,30.75,95, 110,. 115, like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150. 177, and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable Horn rated at 884 dBA at 16 volts installers to easily adapt devices to meet requirements. •• Rated from-40'F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Ouldoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion.Knock-outs located on the back eliminate the need to drill SIGNALING x1l holes for screw-in mounting.Plastic and metal weatherproof back 10 U1 I boxes come with'A-inch lop and bottom conduit entries and -inch ao e- ei i°u c t.best LISTED re �P� approvedMEA 12 °s.:ee 1, r.., °knock-outs at the back.A screw-in NPT plug with an 0-ring gasket i 2C,57E,_ a.,;rY1-e , :.ESa.ear, _n m=-; for a watertight seal is included with each back box. • SpectrAlert Advancea9Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns,strooes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.Ttie notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circult'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts,When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135,150, 1 77,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall he approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system..The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On tour-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must.he installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications_(t (,f1rf�; )T Operating Temperature 40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second• Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4,7"W x 2.5'D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.61 x 4.7-W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"'D(145 mm L x 130 nun W x 51 rnm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated.time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. • AVOSV12ur 0 UL Current Draw Data oe-gent Draw A ,-. .;..1:66 UL Um''. I I N 8-175 Volts 16-33 Volts i-175 Voile 1:8-.33 Volts Candela DC FWR......._ DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 €6 71 Temporal Hlg'n 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 ----_--- 185 NA NA '286 258 •UL Max.Current Draw(ma RU '2-Wire Horn ShalahAtindeadtenRIM nelnitattS-115 pd) ;` 8-175 Volts 1b-.-3 5 Lott:;. DC Input 15 15/75 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-lernporalLuw 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Ternporal Medium 129 152 78 88 103 160 184 202 206 • lemporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High CandelaRange(1�85 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 23' 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 202 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Hem Oe ;) candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output foci) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40`F Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal • 150 150 71 Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 91. Coded Low 75 75 81 81 88 85 96 92 rSettings 7,8,and 9 are not available on 2-wire horn strobe. AV:Goi2r.. • SpectrAlert Advance Diagrams t. II(( ))1 5.6" ro y 11111) /,� at illyJI— irk" Wail-Mount Horn Strobes --\\�^� Jl Wall Plastic Weatherproof Back Box 4 >!=I 1, 0 uP - " : -• Ili . Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall Horn Strobes P2 iK'- 2-Wire I loon Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back ricx) P2R IK*I 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK1i 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK`t 2-Wire Horn Strobe,High ed.White,Outdoor(includes plastic weatherproof back box) P4RKI 4-Wire Horn Strobe.Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard od,White,Outdoor(includes plastic weatherproof back box) P2Rr1K-'20 2-Wire Horn Strobe,High cd,Red Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK'l Strobe Standard cd,Red.Outdoor(includes plastic weatherproof back box) SRHK•t Strobe.High cd Red,Outdoor(includes plastic weatherproof back box) SWK"" Strobe.Standard cd,White.Outdoor(includes plastic weatherproof back box) SWHK't Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKI Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: 'Add"-P"to model number for plain housing(no'EIRE"marking on cover),e.g.,P2RK-P. t Add"-(7"to model number for weatherproof replacement device;no back box Included),only for Joe with weatherproof outdoor flush mounting plate,WTP and WTPW. 'Standard cd'refers to strobes that include 15,15/75,30,75.95, 11 c,and 15 candela settings."High cd"refers to strobes that include 135. 150-'177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. • STEM 3825 Ohio Avenue•St.Charles, IL 60174 r ,„ im for r� I Y,r yr wn SENSOR Phone:800-SFNSOR2•Fax:630-377-6495 rvu m� i v • 'iisrtal Indoor Selectable- R Output Horns, ,, t ,4 „ Strobes, and 4�1 Horn Strobes for Wall Applications System Sensor L-Series audible visible notification it, 1. . i. products are rich with features guaranteed to cut51%' � �� installation times and maximize profits with lower �� f ; t current draw and modern aesthetics. Features • • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns:strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Plug-in design with minimal intrusion into the back box plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns,strobes,and horn strobes • Field-selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110, 135,and 185 while simplifying installation.All devices feature plug-in designs • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume,selections and foolproof while virtually eliminating costly and lime-consuming ground faults. • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,the L-Series utilizes a universal mounting plate for all • Electrically Compatible with legacy SpectrAlert and SpectAlert models with an onboard shorting spring,so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MUL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings. automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING mom,. t_4`i APPROVED .a `' LISTED wi '),ede.L.ep. nz 1653,,.un IQr ALEN.moneu: gy135-1e,3(Mk 3:',:i0103,3D'ilf,]I • L-Series Specifications Architect/Engineer' ' N • General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 '/e-incn back box,4 x 4 x 1%-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x l e,einch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'"'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts,When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts.24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor [-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 110. 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall he wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L.-Series Model listed to LA L 1971 and HI_464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at'I Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The norn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UI.464 and shall he approved for fire protective service,The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more • synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Itiricabeectdcal Specifications Standard Operating Temperature 32°F to 120`F(0 C to 49'C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR" Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wail-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91"0(143 min L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"Lx 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6'1 x 4.7""W x 1.25'D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) 1,Full Wave Rectified(FWR)voltage is a non-regulated,tune-varying power source that is used on some power supply and panel outputs. 2,Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. • • UL Current Draw Data X. OeDa ra mtRM .. _ i ! ��l.� mcurrent t ARMSJTa^t�tt F� 8-175 Volts 16-33 Vohs 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 u ti .. 1.DOWN..(mA MS), -Wire Horn strabee 1 �I 8-175 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts • FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 '02 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output ,.p,)11 8-175 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 _ 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 • 9' Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 "Settings 9 and 10 are not available on the 2-wire horn strobes. • L-Series Dimensions c_ 1.91 3.46 ..,,— 1.25 1.25 I 111.1 h rr Irrt Qo .aa 1:I 5.27 III 5.27 a pat u• 0 a • par rt IJILI 41 L -z ., . Compact Strobe 1 Horn Strobe Compact Horn 4.70 -- -‹- - 1.91 1.25 4.70 1.25 5.67 .67 } U : ���� rh r I ill Strobe/Horn Strobe Horn • L-Series Ordering Information ,.�•Ntii eisioiridon.. Model Descriptio n Wall Horn Strobes Horns P2RL 2-Wire:Horn Strobe,Red HRL Horn,Red P2WL 2-Wire,Horn Strobe,White HWL Horn.White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL Compact Horn,Red P2GWL 2-Wire,Compact Horn Strobe,White HOWL Compact Horn,White P2RL-P 2-Wire,Horr Strobe,Red,Plain Accessories P2WL-P 2-Wire.Horr Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horr Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red Wall Strobes SBBRL Wall Surface Mount Back Box,White SRL Strobe,Red SBBGRL Compact Wall Surface Mount Back Box,Red SWL Strobe,White SBBGWL Compact Wall Surface Mount Back Box,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe.White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have'FUEGO"marking on cover All-ALERT models have'ALERT"marking on cover • 3825 Ohio Avenue•St.Charles, IL 60174 o, o,tE Sensor. t`,�..� Phone:800-SENSOR2•Fax 630-377-6495 q t� v xctluc ! m M1 i ctaM�1 the ktteU veaio th s tlak.vne� www.systemsensor.com Avnsvei', om • . IYi? Outdoor Selectable- „p„: • Output Strobes and Horn Strobes for Ceiling Applications SpectrAlertt Advance outdoor audible visible products SPECT4gert are rich with features that cut installation times and A to v o nu a IE maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof NEMA 4X, IP56 rated strobes,and horn strobes in the industry.With white or red plastic Listed to UL 1638(strobe)and UL 464(horn) housings,wall or ceiling mounting options,and plain or FIRE-printed + devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from-40°F to 151°F. • Field-selectable candela settings:15, 15/75,30,75,95,110, 115, Like the entire SpectrAlert Advance line,outdoor strobes and horn 135, 150, 177,and 185 strobes for ceiling applications include a variety of features that • Automatic selection of 12-or 24-volt operation at 15 and increase application flexibility and simplify installation.First,field- 15r75 candela selectable settings,including candela,automatic selection of 12-or • Rotary switch for horn tone and three volume selections 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from-40°F to 151`F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without • mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion. Plastic and metal weatherproof back boxes come with O (:� - -inch top and bottom conduit entries and 34-inch knock-outs at the 11) • Rne}t back.Three screw-in NPT plugs with 0-ring gaskets for a watertight 'dIEA '330 °a i°7�°m° s .r.;r LISTED approve s 653188361991,905. seal is included with each back box. sal lf9m',,..Iv�fi!°n.,a.oo.�fi) APPROVED?.658Pp cnme.rr.CVII -s.'553 fouitlmr sno a et oroneO ac:15/• .2E Ec2_05{ rl 35.1F.5}:i80 thorns.oMmasr • SpectrABert Advance Outdoor Strobe, and Horn Strobe Specifications ArchitectlEngineor Spirbtfications', !I . General SpectrAlert Advance outdoor horns,strobes,and horn strobes snail mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'"Module accessory,shall he powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts,When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30, 75,95, 110, 115, 135, 150,177,and 185. Strobe The strobe shall he a System Sensor SpectrAlert Advance Model listed to UL 1638 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Ham Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1638 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall he set by a multiple position switch.On four- wire products,the strobe shall be powered independently of the sounder.The horn strobe on a 2-wire model shall work on a non-coded power supply The horn on 4-wire horn strobe models shall operate on a coded or non-coded power supply The horn strobe must be installed with its weatherproof hack box in order to remain outdoor listed per UL. The horn strobe shall be suitable for use in wet environn ents- Physical/Electrical Speelficalt 1 t ih rpa 7 eP+lily = Operating Temperature —40°F to 151°F(-40°C to 66°C) • Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range with MDL3 Sync Module 8.5 to 17.5V(12 V nominal)or 16.5 to 33V(24 V nominal) input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.6 diameter x 2.5"high(173 mm diameter x 64 mm high) Strobe/Horn Strobe Dimensions 5.6'1 x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Strobe/Horn Strobe Dimensions with Back Box 5.6 L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm Dl Ceiling-Mount Weatherproof Back Box Dimensions 7.1-diameter x 2.0"high(180 mm diameter x 51 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated, limo-varying power source that is used on some power supply and panel outputs. 2.Products will operate at 12 V nominal only for 15 and 15/75 cd. AUG"1,13". • UL Current Draw Data It)ent Draw(mA} . ' .1 i Amax...Mamsawrintaraw for 4-Wire Horn Strobes(mA RMS) 8-175 Volts ;,,-33V'olts 8-17.5 Volts 18-33 Volts Candela DC FWR Dr. FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 SO 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 226 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 :1,1L Max Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Ra nge(1S'A c) ' ' " 1' 8-1Z5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Nor-Temporal Medium 133 145 75 85 102 163 187 207 216 Nor-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 86 103 160 184 202 206 • Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe.High Candela Range(135--185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWRlnput 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 'temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non TemporalLow 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn Strobe Output(dBA) candela ratings must be reduced in accordance with 3,,,175 18,,,33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anecholc Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40'F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32"F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal • 150 150 71 Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 'Settings 7..8,and 9 are not available on 2-wire horn strobe. AVosnaa+ • SpectrAlert Advance Diagrams 6.8" \ H Dia. d) ,,I z.b p R Ceiling-Mount Horn Strobes Ceiling Plastic Weatherproof Back Box ((I1 i ' !jii 4.4 1 • Ceiling-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description ,r , Ceiling Horn Strobes _ PC2HK 2-Wire Horn Strobe,Standard cd,Ned,Outdoor(includes plastic weatherproof back box) PC2RHK 2-Wire Horn Strobe, High cd,Red,Outdoor(includes plastic weatherproof back box) PC2WK 2-Wire,Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) PC2WHK 2-Wire,Horn Strobe.High cd,White.Outdoor(includes plastic weatherproof back box) Ceiling Strobes SCRK Strobe,Standard cd,Red.Outdoor(includes plastic weatherproof back box) SCRHK Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SCWK Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SCWHK Strobe,High cd,White,Outdoor(incudes plastic weatherproof back box) Accessories SA-WBBC Red,Metal Weatherproof Back Box SA-WBBCW Wnite,Metal Weatherproof Back Box MP120K Notes: "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes lnat include 135.150,177,and 185 candela settings.When replacing outdoor units,both the device and back box must be replaced. • STEMOhio AIS� hone8 -SEN ue•S• Fax 6 s,377-644 -''' '''''' �. Phone:600-SENSOR2•Fax 630-377-6495 "` ' n r,n me verso a wns-,`a 1 a m �� of Indoor Selectable- .� Output Strobes and ''" `� �� Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification k` products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. " Features The System Sensor L•Series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry • • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics,With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela The entire[-Series product line of ceiling-mount strobes and horn • Field-selectable candela settings on ceiling units: 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring, installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING awnoveo 142,21� • LISTED hn aPPP000 /1L 501 �OrI for ALER Rd/is:Is n3 16530 165305fu 3G5/3N3 • L-Series Specifications Architearoginew Speeffiesdggie,f.ltlfg41). . nrl1. , F General L-Series ceiling-mount strobes'emu horn strobes shall mount to a standard 4 x 4 x 11e-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,[-Series products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor I-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall he a System Sensor[-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements far visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor[-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requ'rements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires,The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. • Physical/Electrical SpeetBeations- lult Standard Operating Temperature 32"F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) InputTerrninal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 rum diameters 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCWL.SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated.time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. • AVL555E00 . UL Current Draw Data LIL Max.P».t,.Strobe Current DraW OnAIRfd h 8-175 Volts 13-33 Volts Candela DC DC FWR 15 37 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max.Current Draw(mA RIMS),2-Wire Horn Strobe 8-175 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 • Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3,1KNon-Temporal High 108 135 179 200 225 255 289 3.1K Nor-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn and Hom Strobe Output ) ° "x"'"i ITS '3 8-175 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AW386830 • L-Series Dimensions 2.47 1.37 ---- ,6.92 - 2.50 E-- C`6.83 _ 1 ' ,6i, cp c: \‘, '\\\('''0 ' i. ' 1 -" 0 • I \S © � / { \ I / Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Afg r� �® � �'■ �r� • ' _��J � ® �I li'I�'i^G;;J1I (l Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information model 37escripdoh' r . �� Mode., .�. . - Ceiling Horn Strobes Ceiling Strobes PC2RL 2 Wire,Horn Strobe,Red SCRL Strobe,Red PC2'JVL 2 Wire.Horn Strobe,White SCWL Strobe,White SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White 0 *--) . , rl, K« , _ss C2017 ncSly=ys,¢4 Sensor 1\ S E S Phone:800-SENSOR2•Fax:630-377-6495 'en�prodrit, cl xfing,nI m a•>. ,sue,, ti l=.91n1- AVosaea, n3 v -GEN€SIa7' • Plenum Rated Power Limited Fire Alarm Cable Part Number: 4515 12 AWG 2 Solid Conductors Ratings FPLP, CL3P, FT6 Approvals UL Listed Construction Conductor 12 AWG Solid Bare Copper Conductor Count 2 Insulation Plenum PVC (0.008" nom.) Insulation Colors Black, Red Lay Length 6.00" nom. Shielding N/A Rip Cord Yes Jacket Plenum PVC (0.015 " nom.) Overall Diameter 0.228" nom. • Print Legend GENESIS P/N 4515 2C 12AWG E175105 (UL) FPLP OR CL3P FT6 75C (RoHS) W/0# XXXXXX-XXXXXXX XXXXFT A B C D E F 1 2 34 5 6 7 89 Properties Operating Voltage 300 Volts max. DC Resistance 1.62 Ohms/1000'at 20°C Capacitance 25.9 pF/ft. nom. Impedance 59 Ohms nom. Temperature -20°C to 75°C Flame Rating NFPA 262 (Plenum); CSA C22.2 No. 2556 (FT6) RoHS Compliant Yes Country of Origin USA • Published:2018-10-19 - NESI - 11. Plenum Rated Power Limited Fire Alarm Cable Part Number: 4507 18 AWG 4 Solid Conductors Ratings FPLP, CL3P, FT6 Approvals UL Listed Construction Conductor 18 AWG Solid Bare Copper Conductor Count 4 Insulation Plenum PVC(0.007" nom.) Insulation Colors Black, Red, Green, Yellow Lay Length 4.50"nom. Shielding N/A Rip Cord Yes Jacket Plenum PVC (0.015" nom.) Overall Diameter 0.157" nom. • Print Legend GENESIS P/N 4507 4C 18AWG E175105(UL) FPLP OR CL3P FT6 75C (RoHS) W/O# XXXXXX-XXXXXXX XXXXFT A B C D E F 1 23456789 Properties Operating Voltage 300 Volts max. DC Resistance 6.52 Ohms/1000' at 20°C Capacitance 32.1 pF/ft. nom. Impedance 58 Ohms nom. Temperature -20°C to 75°C Flame Rating NFPA 262 (Plenum); CSA C22.2 No. 2556(FT6) RoHS Compliant Yes Country of Origin USA i Published:2018-10-19 . -GENESIS- Plenum Plenum Rated Power Limited Fire Alarm Cable Part Number: 4506 18 AWG 2 Solid Conductors Ratings FPLP, CL3P, FT6 Approvals UL Listed Construction Conductor 18 AWG Solid Bare Copper Conductor Count 2 Insulation Plenum PVC (0.007" nom.) Insulation Colors Black, Red Lay Length 2.25" nom. Shielding N/A Rip Cord Yes Jacket Plenum PVC (0.015" nom.) Overall Diameter 0.136" nom. • Print Legend GENESIS P/N 4506 2C 18AWG E175105 (UL) FPLP OR CL3P FT6 75C (RoHS) W/O# XXXXXX-XXXXXXX XXXXFT A B C D E F 1 2 3 4 56 789 Properties Operating Voltage 300 Volts max. DC Resistance 6.52 Ohms/1000'at 20°C Capacitance 32.1 pF/ft. nom. Impedance 58 Ohms nom. Temperature -20°C to 75°C Flame Rating NFPA 262 (Plenum); CSA C22.2 No. 2556 (FT6) RoHS Compliant Yes Country of Origin USA • Published:2018-10-19