Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
PHOTOVOLTAIC NOTES f P�1.ANINVERTERORANACMODULEINANINTERACTIVEPHOTOVOLTAICSYSTEMSHALLAUTOMATICALL - / SITE DETAIL OFFICE COPY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION UTILITY: POE AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.(NEC 690361) ®GREEN RIDGE ELECTRIC SERVICE: 200A- 2.ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT)CONDUIT FITTING SHALL BE RAIN TIGHT THREAD-LESS Si': ROOF MATERIAL: COMPOSITE SHINGLE COMPRESSION TYPE, aII S O L A R 3.MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED 4.NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER CODE AUTHORITY DISTRIBUTION SWITCH BOARDS,PANEL BOARDS,DISCONNECTING SWITCHES,TERMINAL CABINETS,ETC.ALL a OREGON STATE BUILDING CODE(2018 IBC) NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE OF SUFFICIENT CAPACITY TO WITHSTAND THE OREGON STATE ENERGY CODE(2003 IECC) 5.JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR '�Sii sc�irrnrsi - - NATIONAL ELECTRIC CODE(2020 NEC) APPROPRIATE WATER RUN OFF. Chtr r 'SVN6.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION - " • al rn -r • • SHEET INDEX GREEN RIDGE SOLAR BOX/COMBINER BOXES PER APPROPRIATE NEC REQUIREMENTS. r _,::n 19450 SW MOHAVE CT 7.SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS -..�. - •. A-1 GENERAL NOTES,SHEET INDEX,BUILDING&PROJECT DATA TUALATIN, OR 97062 8.WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS.FIELD APPLIEDI A-2 SITE PLAN PHONE: 503-395-1943 PROTECTIVE COATINGS ARE NOT ACCEPTABLE. I A-3 WIRING&MOUNTING PLAN 9.JUNCTION,PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE WIRING E-1 ELECTRICAL SINGLE LINE DIAGRAM CONTAINED IN THEM CAN BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF MODULE(S)SECURED - E-2 ELECTRICAL CALCULATIONS KARR Y YOER GER BY REMOVABLE FASTENERS AND CONNECTED BY A FLEXIBLE WIRING SYSTEM.(NEC 690.34) E-3 LABELING REQUIREMENTS OPERATIONS DIRECTOR 10.IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM,THE POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX,COMBINER BOX,DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE:"WARNING-ELECTRIC SHOCK HAZARD.THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT MAY BE • F I, ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND FAULTS."(NECE 8,845 D C k W 690.35(F)) 11.ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED 7.6 kW CEC-AC RATING • FROM ANY PHYSICAL DAMAGE -' RECEIVED�� CENTRAL INVERTER SYSTEM 12.ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY. 13.OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. °�•{l / /- ROOF SQFT TOTAL:2425 14.ALL SPECIFIED WIRING IS BASED ON THE USE OF COPPER . t�I 11�� r (� q ARRAY SQFT TOTAL:SOS 15.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION, NOV + " 2020 PERCENTAGE OF ARRAY COMMISSIONING AND ACCEPTANCE WITH THE CLIENT,UTILITY CO.AND CITY INSPECTORS AS NEEDED 16. '' DRAWINGS ARE DIAGRAMMATIC ONLY,ROUTING OF RACEWAYS SHALL BE AT THE OPTION OF THE CONTRACTOR (-� TOROOF: 1% UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 'ffT�' ��F TIGAhs 2 0 17.IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN,THE CONTRACTOR SHALL NOTIFY ELECTRICAL CJF r't DING 1D Ila l�i'II L�.d� ENGINEER TO VALIDATE THE WIRE SIZE.FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. O V L i V 18.WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT,ARISES ON THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES 7650 SW CHERRY DR REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENDURE ® AERIAL VIEW TIGARD, OR 97223 COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEER. L 1 A p I I ITv 19.ALL BROCHURES,OPERATION MANUALS,CATALOGS,SHOP DRAWINGS,ETC.SHALL BE HANDED OVER TO THE 1/9SlJ t_ 1 ,1 OWNER'S REPRESENTATIVE AT THE COMPLETION OR WORK. The City OI TIg`d rd and its 2176 - JANICE MAYER 20.ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT. George pox umveisay (503) 358-7985 21.THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE WITH THE Portland Center employees shall not be"SMACNA"-GUIDLINES FOR SEISMIC RESTRAINS OF MECHANICAL SYSTEMS AND PLUMING PIPING SYSTEMS. , ,Ii ;;,r,,,,;,r,y9 y APN:R459621 22.ALL OF THE LISTED SYSTEMS REQUIRED THAT THE SEISMIC LATERAL FORCE F INCLUDING CONSIDERATION OF resTph ble LOr dlSCre a(')(�`(eS OP AND MP BE DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE SPACING CAN BE CALCULATED. which may appear herein. ACCOUNUTITI1630S40000 TY:PGE THE DISTRICT STRUCTURAL ENGINEER CAN APPROVE THE SEISMIC LATERAL FORCE DETERMINATION. '^-. r 23.A COPY OF THE CHOSEN BRACING SYSTEM(S)INSTALLATION GUIDE/MANUAL SHALL BE ON THE JOB SITE PRIOR TO STARTING THE INSTALLING OF HANGERS AND/OR BRACES. lx.ta ,,,I „_„3.., 313 , METER:24 767 398 24.WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING NON-PRESTRESSED 'mrr gar 9® REINFORCED CONCRETE,USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE REINFORCED BARS. Port VALIDITY OF PERMIT WHEN INSTALLING THEM INTO EXISTING PRE-STRESSED CONCRETE TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION.EXERCISE EXTREME CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE ISSUANCE OF A PERMIT THE TENDONS DURING INSTALLATION.MAINTAIN A MINIMUM CLEARANCE OF ONE INCH BETWEEN THE QAgilyx Corporation "` DATE DESCRIPTION REINFORCEMENT AND THE DRILLED-IN ANCHOR. BASED ON CONSTRUCTION --- 25.THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW DOCUMENTS AND OTHER DATE 08 17 2020 ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. 7650 Southwest REVISED: 26.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNUGHT RESISTANT.(NEC 300.6 01,310.8 DI •CherryDrive X DATA SHALL NOT PREVENT 27.GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE Contluent` THE CODE OFFICIAL FROM DATE 08 16 2020 OF THE SYSTEM.(NEC 250.97) \ REVISED: 28.THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF SMALLER THAN REQUIRING THE CORRECTION DATE 46 COPPER WIRE.(NEC 250.64 B) 06/23/2020OF ERRORS.ORSC 105.4 DRAWN: 29.GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT BUSBARS "" CID WITHIN LISTED EQUIPMENT.(NEC 250.64C) i DRAWN BY: S.H. 30.RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END.(CEC 250.64(El ' 31.WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION,A SIGN WILL BE PROVIDED WARNING OF THE HAZARD PER NEC 690.17.34.EACH UNGROUNDED CONDUCTOR OF THE MULT-I WIRE BRANCH CIRCUIT WILL BE IDENTIFIED PER PHASE AND SYSTEM PER NEC210.5. GENERAL 32.CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC250.97&250.92(B)&LAMC 93.250.97. '? 33.DC CONDUCTORS EITHER DO NOT ENTER THE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Genscc Inc °°+, ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER NEC 690.31(E),LAMC 93.690.31(E) CITY OF TIGARD 34.ALL METALLIC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS(CONDUIT,JUNCTION tB r'.--rr CI l NOTES &PULL BOXES,RACEWAY,ETC)SHALL BE SOLIDLY GROUNDED PER THE MANUFACTURER'S INSTALLATION REVIEWED FOR DE COMPLIANCE INSTRUCTIONS LAMC 93.690.110.3&93.110.3(B). Contract 35.SCREWS,NUTS,BOLTS&WASHERS THAT ATTACH EQUIPMENT GROUNDING LUGS SHALL BE STAINLESS STEEL Furnishings Marto Approved: PROJECT DATA LAMC 93.110.3(B). 36.NO PIPING,DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE OTC: r 7 LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. [ J 37.ALL FIELD INSTALLED JUNCTION,PULL AND OUTLET BOXED LOCATED BEHIND MODULES OR PANELS SHALL BE Permit #: � (�V �✓ 1��^�` O('� (q ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE(S)OR PANEL(S)SECURED BY REMOVABLE FASTENERS. / l�S� i, \ ^L� / 38.REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING Address: ) of CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR QVIC f�I TY MAP Approved plans ,. OUTPUT CIRCUIT GROUNDED CONDUCTOR. suite #: shah! be on job site.39.THE ROOF MOUNTED PHOTOVOLTAIC MODULES,PANELS,OR SOLAR VOLTAIC ROLL ROOFING MATERIAL (I SHALL HAVE THE SAME OR BETTER LISTED FIRE-RESISTANCE RATING THAN THE BUILDING ROOF-COVERING By: Date: 11/2,(2/3 A _ 1 MATERIAL. l 40.ALL ROOF MOUNTED CONDUIT WILL BE A MINIMUM 1/2"OFF THE ROOF SURFACE. @ GREEN RIDGE SOLAR I TILT 17° o AZIMUTH 181° GREEN RIDGE SOLAR \ //ill9G'�1w�1� 19450 SW MOHAVE CT TSRF 79% 0TUALATIN, OR 97062 PHONE: 503-395-1943 ■ / II/IIIIIIII/III, I \ r f „r.,.•I 36'-0" 1 KARRY YOERGER /// r- rr / OPERATIONS DIRECTOR /I 2 0 rr / ■ 58 —1 (N) ROOF MOUNTED PV ARRAY . OC bw U zr 8. 845 DC kW 6 SEG-6MB-305BB �.- F.," I Q • 7.6 kW CEC-AC RATING MODULES 305 WATT I • • CENTRAL INVERTER SYSTEM 6 X SOLAREDGE P400 OPTIMIZERS o ROOF SOFT TOTAL: 2425 ',. 3- ■ ■ TDRIVEWAY ARRAY SQFT TOTAL:508 OF A (N) ROOF MOUNTED PV ARRAY / PERCAGE Zo TOT ROOF:21gRRAY 7 SEG-6MB-305BB ■ ■ ■ / (E) UTILITY MODULES 305 WATT """" "' """ / METER 7650 SW CHERRY DR 7 X SOLAREDGE P400 OPTIMIZERS ;:i- TIGARD, OR 97223 1 coI TILT 17° ■ 1 2176 - JANICE MAYER AZIMUTH 181° ■ (503) 358-7985 TSRF 79% �/� 2'-0"E APN:R459621 UTILITY:PGE MSP i /t ACCOUNT:1630540000 (N) CUSTOMER rg LAYOUT PLAN METER:24 767 398 GENERATION / AC DISCONNECT SCALE: NTS (OUTSIDE) MN I Il o DATE DESCRIPTION (N) SOLAREDGE \ TILT 17° DATE 08/17/2020 SE7600H-US DATE REVISED: o AZIMUTH 90° PV STRING INVERTER in TSRF 71% REVISED: 08/16/2020 i WITH DISCONNECT DATE (OUTSIDE) (E) MAIN (N) ROOF MOUNTED PV ARRAY DRAWN: 06/23/2020 200A SERVICE 8 SEG-6MB-305BB LEGEND DRAWN BY: S.H. PANEL (INSIDE) MODULES 305 WATT (N) ROOF MOUNTED PV ARRAY 8 X SOLAREDGE P400 OPTIMIZERS (E) EXISTING 6 SEG-6MB-305BB (N) NEW SITE MODULES 305 WATT UM UTILITY METER 6 X SOLAREDGE P400 OPTIMIZERS MSP MAIN SERVICE PANEL PLAN ACD AC DISCONNECT INV INVERTER SITE PLAN CP SOLAR COMBINER PANEL SCALE: 1 /16"=1 ' BAT BATTERY BP BACKED—UP PANEL - 2 .... i f- IC GREEN RIDGE SOLAR 2'-2" // - - _.- -0- - -A4/ _ - -6� 19450 SW MOHAVE CT - - �7- - - - - - ■ - - - -0-- - - 6 PHONE: 503-39571943 - - - - -0- — �- - - - - -0 - - -/� KARRY YOERGER - - �- - - - - - - - - - - OPERATIONS DIRECTOR - - -8 - -0 --/ • - - -9� -9 - - ■ 8.845 DC kW 1 O - V - - - - -v- 7.6 kW CEC-AC RATING / / 3 -011 CENTRAL INVERTER SYSTEM - $ - -0- -0 ROOF SQFT TOTAL:2425 I I I I I - - - -/ ■ ARRAY SOFT TOTAL:508 I I I I I PERCENTAGE OF ARRAY • I I I - / - - TO ROOF:21% ? I iQ � � ■ p 7650 SW CHERRY DR b b PU/(////(////(////(/////////P///#//4////(////(//M/7 1TIGARD, OR 97223 III `! IIl 2176 - JANICE MAYER (503) 358-7985 h /// p I p APN:R459621 N 1 I /(I I ■ ACCOUNT:1630540000 METER:24 767 398 \ I I 1 1 1 1 ° DATE DESCRIPTION \ I I I I I / REVISED: 08/17/2020 I 0 REVISED: DATE 08/16/2020 I I I I I I / / 4'-0" TYP . DRAWN: 06/23/2020 DRAWN BY: S.H. // 2'-0" O . C . TYP . 3'-0" FIRE ACCESS / / MOUNTING PLAN A - 3 FRAMING NOTES SIZE 2X6 CONSTRUCTION GREEN RIDGE TYPE STANDARD STICK FRAME SOL A N CROSS SECTION ( 336) RAFTER SPACING 24"O.C. _ _. I Mil I.02 , #2 COLLAR TIE \ COMPOSITION ( 3,67) GREEN RIDGE SOLAR SHINGLE ; 19UALLATIN,MOHAVE 9 0 2T 450 SW PHONE: 503-395-1943 ItillIP01 ii; ° © KARRY YOERGER Lo x i0,_0„ --7/ OPERATIONS DIRECTOR CV EXTERIOR v 0 L.0 � WALL - THIS EDGE TOWARDS ROOF RIDGE I ' Y8.845 DC kW r I� .__ 7.6 kW CEC-AC RATING Load Bearing Walls Extend CENTRAL INVERTER SYSTEM Down to Foundation - ROOF SQFT TOTAL:2425 ARRAY SQFT TOTAL:508 \` , PERCENTAGE ROOF:21%BRAY 1 L ( 12.60) ez) '00 7650 SW CHERRY DR TIGARD, OR 97223 ` :�'oi I 2176 - JANICE MAYER (3 00) (503) 358-7985 FLASHFOOT 2 AERIAL VIEW4 , ,. APN:R459621 UTILITY:PGE 4.50;� �9.00; i ACCOUNT:1630540000 METER:24 767 398 FLASHFOOT 2 SIDE VIEW 8 _� 1 DATE DESCRIPTION NO. DESCRIPTION DATE 1 ASSY, FLASHING,MILL OR BLACK REVISED: 08172020D: / / 2 ASSY, CAP, MILL OR BLACK KFi,FLASHFOOT2 DATE 3 BOLT LAC SI 16 X 4.75 Al .o nO zc ut°xnra REVISED: 08/16/2020 a DATE 4 WASHER, EPDMBACKED ,KAU^A �o^t* °' DRAWN: 06/23/2020 DRAWN BY: S.H. TOP SECTION PV MODULE FRONT VIEW PORTRAIT MODULE _ - P.V. QUICK MOUNTS n �`„••I" MOUNTING PLACED 48" O.C. t -I- 1- t PLAN N ACROSS ARRAY P LA -r ,'I..E. II . \___ ....- I'1I ALUMINUM SUNMODO SIDE VIEW PORTRAIT MODULE 111•■�j1111 STANDARD RAIL J �� �, :._I,; EXISTING RAFTER 0A SPACING 24" O.C. 4 1 II J (EXISTING) (N) 29— SEG-6MB-305BB LINE SIDE TAP ^ MAIN PA NEL • 305W MODULE WITH P400 SOLAREDGE (N) SE 7600H—US I GREEN RIIDGE SOLAR OPTIMIZERS SOLAREDGEINVERTER (N) 60A SERV 1 STRING OF 15 MODULES MAX AC OUTPUT FUSED AC DISCO 1 STRING OF 14 MODULES CURRENT= 32A DISCONNECT 200A/ �g�1 OP IiIih - J—BOX QTY, C D 2P(' 19450NSW DMHAVEACT 062 01 • • • A OPTIONAL D`' PHONE: 503-395R 711943 iA N N N c l AL1 ®/ L1 N KARRY YOERGER . . • • • + + + G L1 • U G G L2 L2G �• G UTILITY METER OPERATIONS DIRECTOR G� — — — — (—f i / V G INVERTER DC INPUT VOLTAGE IS WITH INTEGRATED DC VISIBLE, LOCKABLE 8.845 DC kW REGULATED BY SOLAREDGE OPTIMIZER. DISCONNECT AND EXTERNALLY OPERABLE 1 44V 7.6 kW CEC—AC RATING STRING VOLTAGE IS 380VDC NOMINAL. WITH AUTOMATIC RAPID 60A RATED _ L— I CENTRAL INVERTER SYSTEM 480VDC MAX[NEC 690.7] SHUTDOWN UPON 240V, NEMA 3R EXISIIING ROOF SQFT TOTAL:2425 AC GRID UL LISTED GROUND D. ARRAY SQFT TOTAL:508 INVERTER DC INPUT CURRENT IS DISCONNECT DG222NRB ® cp PERCENTAGE OF ARRAY REGULATED BY SOLAREDGE OPTIMIZER. TO ROOF:21% MAX STRING CURRENT IS 4575/380 = 12.04 AMPS 7650 SW CHERRY DR WITH A MAX SHORT CIRCUIT OF 15A TIGARD, OR 97223 [NEC 690.8] 2176 — JANICE MAYER (503) 358-7985 APN:R459621 UTILITY:PGE ACCOUNT:1630540000 METER:24 767 398 DATE DESCRIPTION Wee Hamel Copper J Woe Nichols. I Copper 1.1 DATE Wee Sae NANG(1G51ama) -] Woe Sze 11O AWG(IO4 Mona) Li REVISED: 08/17/2020 Voltage 1210 I Vaava 500 DATE Pismo IG9nolephase H Pbese IAC angle Phase F] REVISED: 08/16/2020 Number or conductors Male set of conductors • Number of conductors circle seta o of codrs R DATE Distance' 120 heal - NumberIOklarxe• 150 I1feet 1.1 DRAWN: 06/23/2020 Load current 140 1Amps Load corn. 115 Mega SERVICE LOAD CALCULATIONS BACKFED 120% PER: NEC 705.12(D)(2)(3XB) AC/DC VOLTAGE DROP CALCULATIONS (LESS THEN 2%) DRAWN BY: S.H. 705.12 (D) (2)(3)(B) WHERE TWO SOURCES,ONE A UTILITY AND THE OTHER AN INVERTER,ARE AC VOLTAGE DROP: 1.01. .42% BUS RATING SIZE MULTIPLIER (120%) RESULT LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS,THE DC VOLTAGE DROP: 1.5 .25% 200A 1.2 240A SUM OF 125%OF THE INVERTER(S) E L E CT R I CA L MAIN BREAKER SIZE INVERTER + 125% RESULT —>OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE 200A 40A 240A PROTECTING THE BUSBAR SHALL NOT EXCEED 120%OF THE AMPACITY OF THE SINGLE 240A</= 240A=OK BUSBAR. WIRE/CONDUIT SCHEDULE LINE DIAGRAM TAG DESCRIPTION CONDUCTOR TYPE/SIZE/QUANTITY CONDUIT SIZE/TYPE A ARRAY TO JUNCTION BOX (4) # 10 AWG PV WIRE & #6 AWG SOLID COPPER (G) FREE AIR PHOTOVOLTAIC SYSTEM DISCONNECT-LABEL INFORMATION B JBOX TO INVERTER (4) # 10 AWG THHN-2 (4+ & 4-) & 1 #8 AWG THHN-2 (G) 3/4" EMT & LMFC RATED MAX POWER POINT CURRENT (TOTAL I MODULES X PMAX)/380VDC 23.28A - _ --- -- _ RATED MAX POWER POINT VOLTAGE NOMINAL DC INVERTER INPUT VOLTAGE 380V C INVERTER TO NON FUSED AC DISCO (3) # 8 AWG THHN-2 (L1, 12 & N) & 1 #8 AWG THHN-2 (G) 3/4° EMT MAXIMUM SYSTEM VOLTAGE MAXIMUM INVERTER INPUT VOLTAGE 4.80V D AC DISCO TO MAIN PANEL (3) # 8 AWG THHN-2 (L1, L2 & N) & 1 #8 AWG THHN-2 (G) 3/4" EMT WHERE EXPOSED E 1 SHORT CIRCUIT CURRENT # OF STRINGS/S X 15 AMPS (MAX OUTPUT CURRENT) 30.OA I IIIN E111ETE ARlNIG F UTILITYIAHJ(PHENOLIC) @ GREEN RIDGE TURN OFF PHOTOVOLTAIC SOL AO I WARNING DUAL POWER SOURCE AC DISCONNECT PRIOR TO _.,.0 • • P'Ali •, • • . ti-na,. WORKING INSIDE PANEL NEC 705.12(B)(3) K ,NEC 110.21(B)&NEC 705.12 GREEN RIDGE SOLAR PHOTOVOLTAIC iTUAL SW MOHA7 ____ OVV CT AR DUALPERSOURCE TUNE PHONE:: 50 OR 93-395— —1943 *' E ISPHOT41t�Li Ei KARRY YOERGER NEC 705.12(B)(3) UTILITY PLACARD AS NEEDED OPERATIONS DIRECTOR AC DISCONN SUPPLY SIDE TAP NEC 690.13(B) 8.845 DC kW • '•` AS REQUIRED IF PV 7.6 kW CEC—AC RATING A WARNING I . INTERCONNECTION IS CENTRAL INVERTER SYSTEM , 7 MADE TO SUPPLY SIDE OF ROOF SQFT TOTAL:2425 INVERTER OUTPUT CONNECTION DO SERVICE DISCONNECT ARRAY SQFT TOTAL:508 NOT RELOCATE PERCENTAGE OF ARRAY THIS OVERCURRENT NEC 690.53 DEVICE TO ROOF:21% L. • PHOTOVOLTAIC DC DISCONNEC NEC 705.12(B)(2)(3)(b) OPERATING VOLTAGE 380 V OPERATING CURRENT 23.28 AI 7650 SW CHERRY DR MAXIMUM VOLTAGE 480 V I TIGARD, OR 97223 MAXIMUM CIRCUIT CURRENT 30.0 A I ____J 2176 — E (503) 358-7985JANICEMAY R NEC 690.56 APN:R459621 PGE 4"HOTOVOLTAIC SYSTE ' ;, UTILITY::105 ACCOUNT:1630540000 EQUIPPED WITH METER:24 767 398 SOLAR PV SYSTEM EQUIPPED - RAPID SHUTDOWN WITH RAPID SHUTDOWN pil _ ® NEC 690.31(G)(3)&(4) � W .MM TURN RAPID SHUTDOWN = liWARNING. PHOTOVOLTAIC DATE DESCRIPTION SWITCH TO THE •OFF'POSmONTO ,. '!.4,�, POWER SOURCE DATE SHUTOOWN PV SYSTEM REVISED: 08/17/2020 APn REDUCE ADHESIVE FASTENED SIGNS DATE SHOCK HAZARD * THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. 2020 16 IN THE ARRAY • WHERE REQUIRED ELSEWHERE IN THIS CODE. ALL FIELD APPUED LABELS. WARNING, REVISED: OS/ / g AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21 (B) FIELD MARKINGS. DATE NEC 690.56(C)(1)(a) �l * ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS DRAWN: 06/23/2020 SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] PHOTOVOLTAIC DC DISCONNECT J DRAWN BY: S.H. MAXIMUM AC OPERATING CURRENT EMI 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL AND LABELED FOR IT MAXIMUM AC OPERATING VOLTAGE ALL CONDUCTORS WARNING: PHOTOVOLTAIC 2.) ALL CONDUCTORS SHALL BE COPPER RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. NEC 690.54 POWER SOURCE 3.) WIRING, CONDUIT AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED LABELING NEC 690.31 )O&(4)G 3DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP ( OR VALLEY. SYSTEM DC CIRCUIT CONDUCTORS.EXPOSED RACEWAYS,CABLE TRAYS&OTHER WIRING 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT REQUIREMENT A WARNING METHODS.COVERS OR ENCLOSURES OF PULL BOXES&JUNCTION BOXES.CONDUIT BODIES IN SHALL COMPLY WITH NEC 110.26. 5. WHICH ANY OF THE AVAILABLE CONDUIT OPENINGS ARE UNUSED. ) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR ELECTRIC SHOCK HAZARD LABELS OR MARKINGS SHALL BE VISIBLE AFTER INSTALLATION.REFLECTIVE WITH 3/8'UPPERCASE, TOA ULL LFILLFUN APPLICABLE ALLGCODESYAND STANDARDSORTS, FITTINGS AND ACCESSORIES DO NOT TOUCH TERMINALS WHITE ON RED.EVERY SECTION OF THE WIRING SYSTEM SEPARATED BY ENCLOSURES,WALLS, 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS AND CONDUITS ARE NOT SPECIFIED, TERMINALS ON BOTH LINE AND PARTITIONS,CEILINGS,OR FLOORS.SPACING BETWEEN LABELS OR MARKINGS SHALL NOT BE THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. LOAD SIDES MAY BE ENERGIZED MORE THAN 10' 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELE AND READILY VISIBLE. IN THE OPEN POSITION RAPID SHUTDOWN 8.) MODULE GROUNDING CUPS TO BE INSTALLED BETWEEN MODULE FRAME AND NEC 690.13(B)&NEC 690.115(D) SWITCH FOR MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. SOLAR PV SYSTEM 9.) MODULE SUPPORT RAIL TO BEBONDED TO CONTINUES COPPER G.E.C. VIA WEED E _ 2 LUG OR ILSCO GBL-4DBT LAY-IN LUG. ` NEC 690.56(C)(3) 10.) THE POLARITY OF THE GROUNDING CONDUCTORS IS NEGATIVE. / r -���/' �„\ \� \ SEG-6MB-xxxBB SERIES 6 INCH 60 CELLS SEG-6MB-xxxBB SERIES 6 INCH 60 CELLS SERAPHIM ENERGY GROUP JJJ"' e8 i SLACK BACK-SHEET IBLACK FRAME PRODUCTS Electrical Characteristics(STC) 1 Module Type SEG-6MB-295BB SEG-6M0 300BB (SEG-OMB-305BB . SEG-OMB-310BB 1 mncuon sox-(J Maximum Power at STC-E.,(W) 295 300 305 310 - C000Sng no- 295"'V/l O PERC Open Circuit Voltage-V.(V 39.5 39.7 399 40.2 O SERIAL UMBER ( f !Short Circuit Curren)-L(A) 9.56 9.65 9.76 9.82 Maximum Power Voltage-V„,(V) ., 31.9 32.1 32.3 32.6 0 2�,L Maximum Power Current-I (A) 9.25 9.35 9.45 9.51 Grounding nos I li 8 rvw `1/� Module ERciency STC-qm(%) 18.13 18.44 18.75 19.05 I _ L. lit m „ ��� ) Power Tolerance(W) (0,e4.99) im Maximum System Voltage(V) 1000 or 1500(UL) Resistance to Salt mist Resistance to ammonia Product is certified • - - - - -' negaxva I t n°smve I ) corrosion at your request corrosion at your request by UL1703 Maximum Series Fuse Rating(A) 20 A Connector Fire Performance Type2 or Type1(UT) Reliability Electrical Characteristics(NOCT) 1 111 al Module Type SEG-6MB-295BB SEG-6MB-3008B SEG-6MB-3056B SEG-6MB-310BB P I D O Lib LQ :Maximum Power at NOCT-Pm,(W) 219 223 226 230 Open Circuit Voltage-Vw(V) 36.5 36.7 36.8 37.1 9 7 r 35 Short Circuit Current-Is(A) 7.73 7.82 7.91 7.96 -�--}; �/ el anviance productsm using Worlde het company to pass Bankable nroducs (� advanced module `Thresher Test"and`On-site !Maximum Power Voltage-V�(V) 30.1 30.3 30.4 30.771 c l� technology Power Measurement - i. (, A '.Mazimum Power Current-1 (A) 7.28 7.36 7.44 7.50 Validation"certificate n5 7 `�_./ _i- f) Section A-A 5:1 2:1 10:1 Performance Temperature Characteristics Pmax Temperature Coefficient -0.38%!°C IP ��- e Voc Temperature Coefficient -0.28%/°C 1-0.05%1'C-_ 'All Dimensions in mm \\\:;\• Ise Temperature Coefficient `The above drawing is a graphical representation of the product. t Operating Temperature '40-.95'C I-V Curve High efficiency and enhanced Outstanding power output Withstand up to 2400Pa Nominal Operating Cell Temperature(NOCT) 45H2"C module durability capability at low irradiance wind and 5400Pa snow 10 Celia tome•25,c - inruae ir,so.iron wmr loads(IEC),long lasting Packing Configuration e- inud„t Inn,.=eoowme - --. 1640x 992 x 35mm(64.57x39.06x1.371nch) in - _ 6- wwn urea.•m owrnv Container 20'GP 40'GP Pieces per Pallet 30 30 -' a Widen,Me 4 000wrm. _ WARRANTY MANAGEMENT SYSTEM Pallets per Container 12 28 Pieces per Container 360 848 2- I^a>minaa.=2bowmr - 'nn%1 ISO O1401:Quality management system systemMechanical Specifications Voltage n 9adq d e% Ve .,o w. OHSAS 18 01 Inte national standard formanagementl occupational health and safety assessment system --- --, 0a 1n 2d j sa 2xx ° d0 no x.ea1L °'"ua. is0% OROSW n Extama Dimensions 1800 x 992 x 35 mm 84.5]x3e06x1 3I inch) 10 eanew Weight 17.5 kg(3&S lbs) iron% PRODUCT CERTIFICATES Solar Cells Mowcwa;alrxle,6 lnch(6opcs.) SO% is 20 s Front Glass 3.2 mm AR coating tempered glass.low iron b O ves.s w ///ssx !F'UMW MN 4 -.. Anodized -.- e a 60--x \n C E SETA rie ryf Frame Anod etl aluminium elo ko- aw a•t000 tom V\ Inds.xb� SigBGA� Junction Box IP67 1 O C US umaxie Aw " Cobtotemp. so6 Guarantee on product �i material and workmanship Output Cables 12Aw0.<acie lengthy one mm 2 =e%mo.:wc _ YEARS -eeucemx.•ro e INSURANCE Connector MGa Compatible dO 10 20 20 40 50 2 STC Irradiance 1000 W/mf module temperature temperature AMnd.s wyeM Linear power output warranty PlaNOCT:Irradiance a subject W/mo,change nwimperuture 20°C,wind speed:1 m/s YEARS Specifications are subject to change without further notification. Specifications are subject to change without notification SEG-DS-EN-2019V1.1®Copyright 2019 Seraphim Specifications are subject to change without notification SEG-DS-EN-2019V1.1®Copyright 2019 Seraphim SERAPHIM ENERGY GROUP, INC. SERAPHIM ENERGY GROUP, INC. i Single Phase Inverter / Single Phase Inverter with HD-Wave Technologyfor North America With HD-Wave Technologyfor North America • SE3000H-US / SE3800H-US / SE5000H-US / SE6000•- _ S/ SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US SE7600H-US / SE10000H-US / SE11400H-US Model Number SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US Model Number SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH ADDITIONAL FEATURES •• PART NUMBER SEXXXXH-XXXXX6XX4 - - -- - Supported Communication Interfaces RS485,Ethernet,Zig8ee(optional),Cellular(optional) OUTPUT 3800 @ 240V 6000 @ 240V 11400 @ 240V Revenue Grade Data,ANSI C12.20 Optional" Rated AC Power Output 3000 VA 3300 @ 208V 5000 5000 @ 208V 7600 10000 10000 @ 208V Inverter Commissioning with the SetApp mobile application using built-in Wi-Fi Access Point for local connection Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 3300 @ 208V 5000 @ 208V 10000 @ 208V 2017 690.12 AC Output Voltage Min.-Nom.-Max. ♦ / Vac STANDARD COMPLIANCE (211-240-264) -— AC Output Voltage Min.-Nom.-Max. Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCaccording to TitM-07 (163-208-229) Vac Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) ____ AC Frequency(Nominal) 59.3-60-60.5'1 Hz Emissions FCC Part 15 Class B Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A INSTALLATION SPECIFICATIONS Current @240V Maximum Continuous Output AC Output Conduit Size/AWG 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG Current @208V - 16 - 24 - - 48.5 A Range Power Factor 1,adjustable-0.85 to 0.85 DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG AWG Range GEDI Threshold 1 A__ Dimensions with Safety Switch in/ Utility Monitoring,'standing (HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 mm Protection,Country Configurable Yes Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17 6 lb/kg Thresholds -- Noise <25 <50 dBA INPUT Cooling Natural Convection Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Operating Temperature Range -40 to+140/-40 to+60'0 °F/°C Maximum DC Power @208V - 5100 - 7750 - - 15500 W - -- Protection Rating NEMA 4X(Inverter with Safety Switch) Transformer-less,Ungrounded Yes - Maximum Input Voltage 480 Vdc in Revenue grade inverter P/N:SExwaxH-US000BNC4 Nominal DC Input Voltage 380 400 Vdc Full power up to at least 50°C/122°F;for power de-rating information refer to:httpsJ/wwwsolaredge.com/sites/default/files/se-temperaturu-derating-note-na pdf Maximum Input Current @240Va' 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208VP° - 9 - 135 - - 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kst Sensitivity Maximum Inverter Efficiency 99 L_ 99.2 % CEC Weighted Efficiency 99 99 @ 240V % 98.5 @ 208V Nighttime Power Consumption <2.5 W n,For other regional settings please contact SolarEdge support PI A higher current source may be used,the inverter will limit its input current to the values stated ©Solartd Technologies,Inc.All rights reserved.SOLAREDG the SolarEd elo o,OPTIMIZED Re SOLAREDGE are trademarks orre registered trademarks of solarEd a Technologies,Inc All 9e 9E 9 9 u 9 9 Q other trademarks mentioned herein are trademarks of their respective owners.Date:52R19AM1/ENG NAM.Subject to change without notice. •�Q w Power Optimizer 10 For North America Power Optimizer O P320 / P340 / P370 / P400 / P405 / P505 P370 For North America OptimizerP340 g P400 rhigP50 I pcl model (for 60-cell (for hi her- P405 (for high- (for 72&96- (for higher P320 / P340 / P370 / P400 / P405 / P505 (typical module modles) Pow 60-cell 60anod72-cell cell • (fmodules)or thin m current modules) modules) modules) modules) mINPUT • Rated Input DC Poweie 320 1 340 370 \ 405 505 W 2 � Absolute Maximum Input Voltage 48 60 80 125,4 870 Vdc (Voc at lowest temperature) YEAR MPPT Operating Range 8-48 8-60 8-80 12.5-105 12.5-87 Vdc WARRANTY Q Maximum Short Circuit Current 11 10.1 14 Adc fist) Maximum DC Input Current 13 75 12.5 17.5 Adc ,01 Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overeohage Category II �� OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current15 Adc Maximum Output Voltageage 60 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE �� INVERTER OFF) !lig N Safety Output Voltage per ±p 1 Vdc Power Optimizer STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109 (class II safety),UL1741 Material UL94 V-0,UV Resistant RoHS "es INSTALLATION SPECIFICATIONS Maximum Allowed System 1000 Vdc Voltage Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(W x L x H) 129x153x27.5/5.1x6x1.1 129x153 x335/ 129x159x49.5/ 129x162x59/ Tan/in 5.1 x6x1.3 5.1 x63 x1.9 5.1x6.4x2.3 Weight(including cables) 630/1.4 750/17 845/1.9 1064/2.3 gr/lb Input Connector Single or dual MC4°I Input Wire Length 0.16/0.52 m/ft Output Wire Type/Connector Double Insulated/MC4 Output Wire Length 0.9/2.95 1.2/3.9 m/ft PV power optimization at the module-level Operating Temperature Range -40-+85/-40-+185 °C/°F Protection Rating IP68/NEMA6P Relative Humidity 0-100 % / Specifically designed to work with SolarEdge Fast installation with a single bolt '^sated power of the module at SIC will not exceed the optimizer'Rated Input DC Power.Modules with up to+5%power tolerance are allowed m NEC 2017 requires max input voltage be not more than BOV inverters "'fur other connector types pease_contact So arEdge / Next generation maintenance with module- / Up to 25% more energy level monitoring PV System Design Using Single Phase Single phase Three Phase 208V Three Phase 480V a SolarEdge Inverter(^"') HD-Wave o Mnlmum Suing Length P320 P340.P370, B 10 18 / Superior efficiency (99.5/D) / Meets NEC requirements for arc fault Popp protection (AFCI) and Photovoltaic Rapid (Power optimizers) P405/P505 _ 6 _ 13(12 with SE3q 14 / Mitigates all types of module mismatch losses, Shutdown System (PVRSS) Maximum String Length (Power Optimizers) 25 25 soil y from manufacturing tolerance to partial 5700(6000 with shading / Module-level voltage shutdown for installer Maximum Power per String SE7600-US 5E11400- 5250 60000 12750m w US) and firefighter safety Parallel Strings of Different Lengths Yes / Flexible system design for maximum space or Orientations utilization For detailed string sizing information refer to http//www.solaredge ccm/sites/defaulpfiles/4ring3izing-na.pdf It is not allowed to min P405/P505 with P320/P340/P370/P400 In nun string 'A string with more than 30 optimizers does not meet NEC rapid shutdown requirement,safety voltage will be above the 30V requirement 1 Fur SE14AKUS/SE43.2KUS'It is allowed to install up to 6,500W per string when 3 strings are connected to the Inverter(3 strings per unit fur 3E43 AUS)and when the maximum power difference between the strings is up to 1,000W s'For SE3OKUS/SE33.3KU5/SE66.61ZU5/SEIOOKUS.It is allowed to install up to 15,000W per string when 3 strings are connected to the inverter(3 strings per unit for SE666KUS/SEtO0KUS) and when the maximum power difference between the strings is up to 2,000W solaredge.com solar • • O Solarrdoe Tecnoogies Ltd.All rights reserved.SOLAREDGE.the SolarEdge logo,OPTIMIZED BY SOLAPEDGE are trademarks or registered trademarks of SolerEdge Technologies,Inc C E Ro H S All other trademarks mentioned herein are trademarks of their respective owners.Date.OJ/2019/V01/ENG NAM.Subject to change without notice. • //r► IRONRIDGE XR100 Rail See Descri tion / Length - [.:; \), Rail Section Properties Property Value Total Cross-Sectional Area 0.582 in2 .66 Section Modulus(X-axis) 0.297 in3 46 Moment of Inertia (X-axis) 0.390 in4 Moment of Inertia (Y-axis) 0.085 in4 Torsional Constant 0.214 in3 Polar Moment of Inertia 0.1261n4 1 99 APPROVED MATERIALS: 2.44 6005-16,6005A-161, 6105-T5, 6N01-T6 2.34 (34,000 PSI YIELD STRENGTH MINIMUM) 1 J .58 1.25 Clear Part Black Part Description/Length Material Weight Number Number XR-100-132A XR-100-132B XR100, Rail 132"(11 Feet) 7.50 lbs. XR-100-168A XR-100-168B XR10Q Rail 168"(14 Feet) Al . 9.551bs. num XR-100-204A XR-100-204B XR100, Rail 204"(17 Feet) 11.601bs. v1.1 . = Cut Sheet IRONRIDGE FlashFoot2 2) Assy, Flashing j*Iiii'-• p I p - 1.0 .29 1jooE ' sdir, . ":. .--_•.. • _ - 112.0- 1I�iProperty Valu�p�� Material Alumin Finish Mill/Black an \ - J ITEM NO. DESCRIPTION 1 BOLT LAG 5/16 X 4.75" 2 ASSY,FLASHING 3 ASSY,CAP 4 WASHER, EPDM BACKED 3) Assy, Cap 4) Washer, EPDM Backed FLASHFOOT 2 .40—10-1 kw- H .38 Part Number Description 0.35 --0- ha-.14 FF2-01-M1 FLASHFOOT2,MILL 1.56 FF2-01-B1 FLASHFOOT2,BLACK 3.35 0 l- 1 ) Bolt, Lag 5/16 x 4.75 0.75 26- -] If 5/16THD 0.63 o 1 Property Value Property Value 7/16" Head 4.75 Material Aluminum Material 300 Series Stainless Steel Finish Mill/Black Finish Clear Property Value Material 300 Series Stainless Steel Finish Clear v1.21 v1.21 SEG-6MB-xxxBB ECEivE® SERIES 6INCH 60 CELLS SERAPHIM ENERGY GROUP Nov 1 0 2020 CITY OF TIGARD BUILDING DIVISION Safety 295^'310w PERc C IMOMOM '� rlri Resistance to salt mist Resistance to ammonia Product is certified corrosion at your request corrosion at your request by UL1703 Reliability PID 0 © Anti-PID products using World 1st company to pass Bankable products advanced module "Thresher Test"and"On-site technology Power Measurement Validation"certificate Performance o High efficiency and enhanced Outstanding power output Wthstand up to 2400Pa module durability capability at low irradiance wind and 5400Pa snow loads(IEC).long lasting WARRANTY MANAGEMENT SYSTEM ISO 9001:Quality management system w3B%'ad" „ •w ISO 14001:Standard for environmental management system m.�% "•"'" OHSAS 18001:International standard for occupational health and safety assessment system W% itwri•T UM% 00% 00�% PRODUCT CERTIFICATES $ 10 IS 30 35 .ears SA® aaK yv ` GEIEORNRISOIM r C�'a i,��,„;., SlotASStSSOSUTION 10 C US Pfuw V Guarantee on product YEARS material and workmanship INSURANCE 25 Linear power output warranty YEARS Specifications are subject to change without notification SEG-DS-EN-2019V1.1©Copyright 2019 Seraphim SERAPHIM ENERGY GROUP,INC. • SEG-6M B-xxxBB SERIES 6 INCH 60 CELLS BB:BLACK SACK-SHEET/BLACK FRAME PRODUCTS Electrical Characteristics(STC) _h 3 Module Type SEG-6MB-295BB SEG41M8-300BB SEG-6MB-305BB 6EG-6M8-310BB uu T tOx_� Maximum Power at STC-Pm(VJ) 295 300 305 310 I Mou,oeo'6' Open Circuit Voltage-V.(V) 39.5 39.7 39.9 40.2 lSERIAL NIMa5R Short Circuit Currentn-Ie(A) 9.56 9.65 9.76 9.82 La ��i Maximum Power Voltage-V,(V) 31.9 32.1 32.3 32.6 Maximum Power Current-Imp(A) • 9.25 9.35 9.45 9.51 crounal�e nuts 8 Module Efficiency STC-qm(%) 18.13 18.44 18.75 19.05 IEl. ' Power Tolerance (W) (0..4.99) Maximum System Voltage V) 1000 or 1500(UL) Maximum Series Fuse Rating(A) 20 )A neg.5ve(-1 somas(.I Connect. I Fire Performance Type2 or Typel(ULi Electrical Characteristics(NOCT) I ,cif Module Type SEG-6M&295BB SEG-BMB-300E1B SEG43MB-30568 SEG8M8-310BB fuf Maximum Power at NOCT-P,R(W) 219 223 226 230 [Open Circuit Voltage-V.(V) 36.5 36.7 36.8 37.1 _ t 1 11111.11.1111 l Short Circuit Current-I. (A) 7.73 782 7.91 7.95 i 11111Pr 'Maximum Power Voltage-Vm_(V) 30.1 30.3 30.4 30.7 _� Maximum Power Current-Imn(A) 7.28 7 36 7.44 7.50 I II 5:1 2:1 Section AA 10:1 Temperature Characteristics Pmax Temperature Coefficient -0.38%/°C Voc Temperature Coefficient -0.28%/'C 'All Dimensions in men °The above drawing is a graphical representation of the product. ISO Temperature Coefficient .0 05%/°C Operating Temperature 40-.85°C I-V Curve Nominal Operating Cell Temperature(NOCT) 451t2"C 1a_ Ga wrp.•n•c - hw1e.X Iml.-coltWine Packing Configuration 5- Incident lm4.-SOD wrm+ - 1640x 992 x 35m5fl(64.57x39.06x1.37 lynch) R- In044m rid..800 W011 _ Container 20'GP 40'GP - F Pieces per Pallet 30 30 ` t- Ina.m.e.-opwim• _ ', Pallets per Container 12 28 380 840 -- - \ Pieces per Container _--- e- incidentm.e.-em WNW - Mechanical Specifications °5 �5 eo so I20 50 Vma'M External Dimensions 1640 x 992x 35 mm(64.57)/39.06x1.37 Inch) 10 , , , Weight 17.5 kg(35.515s) - - - - a Solar Cells Monoerystallims 6lneb(60pes) Front Glass --- --- 32mm AR coating lampeeed glass,low iron _ Frame Matzen aluminium alloy - Junction Box IP67 <-KO5raenA.-1LW Wln4 - -CNa Fmp.-b•C Output Cables 17AV✓G,cable ingtb'1000 mm -Cami4)70•x5•c f -GlsiS,. 55'C Connector MC4 Compatible -Urxwmp.�7a'C STC:Irradiance 1000 Wm',module temperelure25"C,AM=1.5 We to 20Yk'w1 CO xb Se NOCT:Irradiance 800 Wm',ambient temperature 20°C,wind speed:Imes Specifications are subject to change without further notification. Specifications are subject to change without notification SEG-DS-EN-2019V1.1©Copyright 2019 Seraphim SERAPHIM ENERGY GROUP, INC. RECEIVED Eret /lam IRONRIDGE Nov 10 2020 XR1 0 Rail CITY OF TIGARD BUILDING DIVISION See Descri.tion / Length / /4,4 ' .62 F .46 f Rail Section Properties Property Value 1.67 Total Cross-Sectional Area 0.363 in' 1.75 Section Modulus(X-axal 0.136 in3 1.33 iMoment of Inertia(X-axis) 0.124 in° J 58 [1 Moment of Inertia(Y-axis) 0.032 in4 . Torsional Constant 0.076 in3 J Polar Moment of Inertia 0.033 in° 1.00— Clear Part Black Part Description / Length Material Weight Number Number XR-10-132A XR-10-132B XR10, Rail 132" (11 Feet) 4.67 lbs. 6000 series XR-10-168A XR-10-168B XR10, Rail 168" (14 Feet) Aluminum 5.95 lbs. XR-10-204A XR-10-204B XR10, Rail 204" (17 Feet) 7.22 lbs. vi.o Cut Sheet Z./AL IRONRIDGE FlashFoot2 4\.. )--- O .., 1 0 '41 :f U ITEM NO. DESCRIPTION 1 BOLT LAG 5/16 X 4.75" 2 ASSY, FLASHING 3 ASSY,CAP 4 WASHER, EPDM BACKED FLASHFOOT 2 Part Number Description FF2-01-M 1 FLASHFOOT2,MILL FF2-01-B1 FLASHFOOT2,BLACK 1 ) Bolt, Lag 5/16 x 4.75 .63 26--►{ 5/16 THD ft 1I11111111t1111111►1111,(N 7/16' Head b 4.75 Property Value Material 300 Series Stainless Steel Finish Clear v1.20 2) Assy, Flashing 9.0 — / \ 1 1.0 29 >�� 1 � � 12.0 i��/�\ Value t®\ Material Aluminum Finish Mill/Black _ J 3) Assy, Cap 4) Washer, EPDM Backed .40--w-1 H H .38 0.35 ' .14 1.56 II 3.3 O 0.75 Property Value Property Value Material Aluminum Material 300 Series Stainless Steel Finish Mill/Black Finish Clear v1.20 • RECEIVED NOV 10 2020 • CITY OF TIGAIRD Sing I e Phase I nve rte r"UILDING DIVISION Z -W With HD-Wave T a e Technology gy rn for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US m YEAR ) 71:3 • ` WARRANTY O 0 • O • O solar"aT ® O solari [ }� • O O O � O O O • O Optimized installation with HD-Wave technology / Specifically designed to work with / UL1741 SA certified, for CPUC Rule 21 grid compliance power optimizers / Record-breaking efficiency / Extremely small / Quick and easy inverter commissioning directly / Built-in module level monitoring from a smartphone using the SolarEdge SetApp / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article / Optional: Revenue grade data,ANSI C12.20 690.11 and 690.12 Class 0.5 (0.5% accuracy) solaredge.com solar . • • If • Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. I V ✓ s r ♦ s Vac (211-240-264) AC Output Voltage Min.-Nom.-Max. I (183-208-229) Vac AC Frequency(Nominal) 59.3-60-60.51') Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output - 16 - 24 - - 48.5 A Current @208V Power Factor 1,adjustable-0.85 to 0.85 GEDI Threshold 1 A Utility Monitoring,'slanging Protection,Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240Va 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V0 - 9 - 13.5 - - 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ko Sensitivity i Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V % 98.5 @ 208V Nighttime Power Consumption c 2.5 W ^'For other regional settings please contact SolarEdge support v'A higher current source may be used;the inverter will limit its input current to the values stated Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces R5485,Ethernet,Zig Bee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optionaim Inverter Commissioning with the SetApp mobile application using built-in Wi-Fi station for local connection Rapid Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L,M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG 3/4"minimum/14-6 AWG 3/4"minimum/14-4 AWG Range DC Input Conduit Size/#of Strings/ 3/4'minimum/1-2 strings/14-6 AWG 3/4"minimum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/ (HxWxD) mm Weight with Safety Switch 22/10 I 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg Noise <25 ( <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+60R, "F/"C Protection Rating NEMA 4X(Inverter with Safety Switch) 0,Revenue grade inverter P/N:SExxxxH-USOOOBNC4 w Full power up to at least 50-C/122'R for power de-rating information refer to:htipzI/wwwsolaredge.corrVsites/defaulf/files/se-temperature-derating-note-na.pdf ®SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies.Inc All Rol-IS other trademarks mentioned herein are trademarks of their respective owners.Date:1/2019/V01/ENG NAM.Subject to change without notice.