Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
• VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM RE OFRING THE CORRECTION I ERRORS. ORSC 105A OFFICE COPY CITY OF TIGARD REVIEWED POEtiCODE COMPLIANCE Approved: [ ] OTC: [ ] / Permit#: v t bh� oW)' ` `— �3``I� ] Address: p iS s W ��^-�` 12:)( Suite #: By: 161—k Date: t.ljfl/9O . GENERAL NOTES AERIAL VIEW " CODES AND,STANDARDS 1.ALL WORK SHALL COMPLY WITH 2017 OREGON ELECTRIC SPECIALTY CODE(OESC),2019 I OREGON STRUCTURAL SPECIALTY CODE,2017 OREGON RESIDENTIAL SPECIALTY CODE, ' BLUE(J i RAVEN AND ALL STATE AND LOCAL BUILDING AND ELECTRICAL CODES. - i I T E • 2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. [ #4 • , '� 1403 N RESEARCH WAY,BUILDING J SITE NOTES/OSHA REGULATION 1 - A OREM,UT 84097 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. '`- t '°" K " .,, 800-37 ENSO LAR.COM ,`}M WWW.BLUERAVENSO 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY - , $ INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. .. CONFIDENTIAL-THE INFORMATION 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR , HEREIN CONTAINED SHALL NOT BE BUILDING ROOF VENTS. i' $ ` ' USED FOR THE BENEFIT OF 4. ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH - - = '�^-4 ANYONE EXCEPT THIS CODE AND THE APPROVED MANUFACTURERS INSTRUCTIONS SUCH THAT THE ROOF B BE DISCLOSED S IN NOR SHALL IT COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. ''-� IN WHOLE OR IN 5.NO.OF SHINGLE LAYERS:1 PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, PIP41IOW 11.11.1tEXCEPT IN CONNEC TION WITH THE SOLAR CONTRACTOR +I f" I Southwest -t h I.: SALE AND EQUIPMENT, T F THE RESPECTIVE 11 /4'"y+r, If EQUIPMENT,WITHOUT THE 1. MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730 WRITTEN PERMISSION H 2. IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING BLUERAVENSOLAR LLCOF , LUG HOLES PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS. Highland J i h I a „ d D r y w.. 3. AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED (� I E i,�✓i . foil IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION - ' ., ANDAPPROVED BY THE AHJ. /+�BCEP 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE -�7. CERTIFIED NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 's'` •* 5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND E . s= ,+z / PV INSTALLATION SEALED WITH A SUITABLE SEALING COMPOUND. ` 6. DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. " '++ fPROFESSIONAL 7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ s•'� ' ' ' - "' � ." • v #pV ScottG9-016666 SUITABLE WIRING CLIPS. „.-. . 8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR i' y ±fit;m "`; CONTRACTOR: OPS VOC UNLESS NOT AVAILABLE. � �"' ,w � BR$ FIE�DQ 9. ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS, ' - , 385.498.6700 AC PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT _ ''z �' • Highland �}�hl n�� � r_ �, � COMBINERS,AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM [s7j `a. WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4(B). ...... 10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. 11. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN U PROVIDED)IN ACCORDANCE WITH NEC CODE 110.14(D)ON ALL ELECTRICAL CONNECTIONS. ' # '" "' ' `4111114 ' j 0 x ifAAA EQUIPMENT LOCATIONS r 13 1. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL _ LO EQUIPMENT WILL BE PROVIDED AS PER SECTION[NEC 110.26]. - '- 2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING �m • '. Z coc\i CO N TEMPERATURE AS SPECIFIED BY[NEC 690.31 (A)]AND[NEC TABLE 310.15(8)]. DESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX 0 I (� 3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENT _ TO THE UTILITY AC DISCONNECT,OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT, WIND SPEED: 120 MPH CONSTRUCTION - V-B PV1 - COVER SHEET ~ N c N 4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO GROUND SNOW LOAD: 40 PSF ZONING: RESIDENTIAL PV2 - PROPERTY PLAN OFFICE COPY Y. c O w NEC APPLICABLE CODES. WIND EXPOSURE FACTOR: C 2 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN PV3 - SITE PLAN O N 1-11 APPROPRIATE. SEISMIC DESIGN CATEGORY: Du_ m o PV4 EQUIPMENT & ATTACHMENT DETAIL Z Li u) u) PV5 - ELECTRICAL SINGLE LINE DIAGRAM — m Lo a cz > SCOPE OF WORK PV6 - ELECTRICAL CALCULATIONS & 1- >, Co ELECTRICAL NOTES u) - o i— 0 INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM PV7 - MAIN BREAKER DERATE CALCS. DRAWING BY (IF NEEDED) DIN ENGINEERING RECEI , 2.835 kW DC PHOTOVOLTAIC SOLAR ARRAY PV8 - LABELS & LOCATIONS �J ROOF TYPE: Comp Shingle PV9 - CUSTOM DIRECTORY PLACARD DATE NOV 1 0 2020 MODULES: (9) JinKO Solar Eagle 315W M 60CEL BLACK ,,.. q'\IS (IF NEEDED - NEC 690.56(B)) October 27, 2020 INVERTER(S): Enphase IQ7-60 2 US ,---- (- - PROJECT NUMBER CITY OF TIGARD RACKING: Unirac SFM Infinity d LIABILITY 202 Approved plans 86958235 BUILDING DIVISION AG— e ::;ha.!! be on job site. The City of Tigard and its k ` SHEET NAME employees shall not be '�,�' COVER SHEET responsible for discrepancies UTILITY COMPANY: Portland General Electric (PGE) PAGE NUMBER REVISION which may )near herein. PERMIT ISSUER: City of Tigard PV1 0 1 LEGEND \Orr INV INVERTER&DC DISCONNECT BLUE RAVEN SUB (E) SUBPANEL - LC (N) LOAD CENTER 1403 N RESEARCH WAY,BUILDING J AC AC DISCONNECT OREM,UT 84097 N 800-377-4480 M UTILITY METER WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION • MSP MAIN SERVICE PANEL HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF JB JUNCTION BOX ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN TS TRANSFER SWITCH PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, El COMBINER BOXJAGGREGATOR SALE CAIDN U CSOEN OECTH TEIO RCTV0 ❑ 111 EQUIPMENT,WITHOUT THE O PV REVENUE METER WRITTEN PERMISSION OF BLUERAVENSOLAR LLC- O O reFIRE SETBACK EMT CONDUIT RUN ❑ 0 ❑ ❑ 0 ❑ O ❑ ❑ (TO BE DETERMINED IN FIELD) NABCEP • CERTIFIED PV WIRE STRING ///lull/AeA'W. /������//��iiiiii//. r /OM/iii/ii viii����/���///iiii/�//��i PV INSTALLATION p PROFESSIONAL �ccc PROPERTY LINE Scott Gurney M PV-011719-015866 0 S0 Ile Se SCALE: 3/32"=1'-0" CONTRACTOR: c 4• BRS FIELD OPS 12ic ISfc Ileaiiei 385.498.6700 II > Cl FRONT OF HOME -Do ..Y c Lo mi co co Z +s 0.1 co N O = CV L) Q c G) rn N c 2 al ct E -c cm 2 10615 Southwest Highland Drive O� m O O f— Z 11- CA a) u7 -o > c� �_ W U r C/) o I— o DRAWING BY DIN ENGINEERING 1. AC DISCONNECT TO BE LOCATED DATE WITHIN 10 FT. OF METER October 27, 2020 2. ROOF ATTACHMENTS SHALL BE PACED NO GREATER THAN 24 IN. ON PROJECT NUMBER CETNER IN ANY DIRECTION WHERE 86958235 LOCATED WITHIN 3 FT. OF A ROOF EDGE, IP, EAVE, OR RIDGE OSSC 3111.5.3 ITEM SHEET NAME 3.3 PROPERTY PLAN PAGE NUMBER REVISION PV2 0 , LEGEND INV INVERTER&DC DISCONNECT BLUE RAVEN A SUB (E) SUBPANEL - LC (N) LOAD CENTER 1403 N RESEARCH WAY,BUILDING J N AC AC DISCONNECT OREM,UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM M UTILITY METER CONFIDENTIAL-THE INFORMATION MSP MAIN SERVICE PANEL HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT SKYLIGHT BE DISCLOSED IN WHOLE OR IN TJB JUNCTION BOX S TRANSFER SWITCH PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE C COMBINER BOX/AGGREGATOR SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE PV PV REVENUE METER WRITTEN PERMISSION OF p M \ BLUERAVENSOLAR LLC. UNDERGROUND I FIRE SETBACK AA SERVICE LINE p C EMT CONDUIT RUN 4BC--El3 (TO BE DETERMINED IN FIELD) 0 ❑ Q CERTIFIED C PV WIRE STRING PV INSTALLATION PROFESSIONAL ❑ ❑ ❑ ❑ ❑ 0GurneyPROPERTY LINE Scott #PV-01l719-01119A75866 MSP 1 SCALE: 1/8"=1'-0" CONTRACTOR: V.////r5//// ////////////////////////,�6Y///// ////////: /////////// /////////////. BRS FIELD OPS O lJ 385.498.6700 MP1 gc Eic Sfc t # OF MODULES: 9 p AZIMUTH:180° Lac Lac Lac U PITCH:23° c TSRF:96% Lfc Sic Lfc 0 AREA: 1029.64 SQ. FT c n as cn co N z o) N 2 N. LLI Q c TA cm -n m cc E r O 52 LU N O O 1— z u (J) C FRONT OF HOME W °i Lrn 12-CZ cn U) -) o I- 0 DRAWING BY DIN ENGINEERING DATE 1. AC DISCO WON'T EXCEED 10'AWAY October 27, 2020 FROM THE UTILITY METER PROJECT NUMBER 2. ROOF ATTACHMENTS SHALL BE SPACED 86958235 NO GREATER THAN 24 IN. ON CETNER IN ANY DIRECTION WHERE LOCATED WITHIN 3 SHEET NAME FT. OF A ROOF EDGE, HIP, EAVE, OR RIDGE OSSC 3111.5.3 ITEM 3.4 SITE PLAN PAGE NUMBER REVISION PV3 0 PV MODULE(BEHIND TRIM RAIL) Unirac SFM Infinity TRIM RAIL 1.AC DISCONNECT TO BE LOCATED WITHIN - - PV ARRAY INFORMATION 10 FT.OF METER 2. ROOF ATTACHMENTS SHALL BE SPACED BLUE C NO GREATER THAN 24 IN.ON CETNER IN ` LANDSCAPE p L U G RAVEN PV MODULE COUNT: 9 MODULES ANY DIRECTION WHERE LOCATED WITHIN 3 e I . OF ATTACHMENT POINTS: 20 FT.OF A ROOF EDGE, HIP, EAVE,OR RIDGEIL 1 -11 48" MAX. OSSC 3111.5.3 ITEM 3.5 MAX. ARRAY AREA: Module Count x 17.51ft2= 157.6ft2 1403 N RESEARCH WAY,BUILDING J OREM,UT 84097 111 ROOF AREA: 2141.5ft2 r PORTRAIT 800-377-4480 % OF ARRAY/ROOF: 7.4% I 48" MAX. WWW.BLUEHAVENSOLAR.COM ARRAY WEIGHT: Module Count x 501bs =450.OIbs MAX. ARRAY DETAIL, FRONT VIEW CONFIDENTIAL-THE INFORMATION DISTRIBUTED LOAD: Array Weight_Array Area=2.86 IbS/ft2 SFM Infinity Flashkit HEREIN CONTAINED SHALL NOT BE Scale: 3/B"=1'-0" USED FOR THE BENEFIT OF POINT LOAD: Array Weight_Attachments=22.5Ibs/attachment ANYONE EXCEPT RACKING ATTACHMENTS TO BE Unirac SFM Infinity FRAME BLUERAVENSOLAR NOR SHALL IT STAGGERED BY SHIFTING EACH BE DISCLOSED IN WHOLE OR IN SUBSEQUENT ROW OF ATTACHMENTS ® PORTRAIT PART TO OTHERS OUTSIDE ONE RAFTER OVER. RECIPIENTS ORGANIZATION, ® _ EXCEPT IN CONNEC TION WITH THE 'A SALE QUI USE T, ITHUT RESPECTIVE EQUIPMENT, THE THE WRITTEN PERMISSION OF Unirac SFM Infinity ( ' BLUERAVENSOLAR LLC. UNIRAC TRIMRAIL MODULE LANDSCAPE WIDTH NABCEP W PV O Solar Eagle 315W M 60CEL BLACK ' 1 o CERTIFIED WO — PV MODULE p ' ARRAY DETAIL,SIDE VIEW PV INSTALLATION Z (E) ROOF ' 23 Scale:3/8" 1'-0" PROFESSIONAL Q _ I ..__.. = Scott Gurney o 34 EG MEMBRANE xPv-Dims-otsass fi 2.5" UNIRAC SLIDERS AND ODULE CONTRACTOR: I- - TRIMRAIL ROOF ATTACHMENTS WIDTH BRS FIELD OPS H m m , 385.498.6700 J () o 2.5" MIN, EMBED.0 FLASHING a g ROOF TYPE: Comp Shingle W 5/16"STAINLESS STEEL LAG BOLT U ❑ WITH 2-1/2"MIN. EMBEDMENT N ❑ AND FLAT WASHER ROOF FRAMING TYPE: Manufactured Truss C9 (E) BUILDING RAFTER OR TOP CHORD(TRUSS)2x4 © 24"O.C. -p STRUCTURE CEILING JOIST OR BOTTOM CHORD(TRUSS)2x4 @ 24'O.C. c C") Id co - 2 0) ch N O = (Ni I• ui Unirac SFM Infinity Q c N c N (� o w 5 2 w W L.L.JinKO Solar Eagle 315W M 60CEL BLACK 2 O O ~ Z —_ PV MODULE — LL 0 1.. ) Q W coi 1— cu Cl) CD cn� o F- 0 O i,q (E) ROOF DRAWING BY T - 2.5" MEMBRANE w II ! DIN ENGINEERING m UNIRAC SLIDERS DATE October 27, 2020 J U) 2.5" MIN. EMBED.5 I— FLASHING PROJECT NUMBER W p 86958235 5/16"STAINLESS STEEL LAG BOLT _ , = WITH 2-1/2" MIN. EMBEDMENT SHEET NAME AND FLAT WASHER EQUIP. DETAIL (E) BUILDING STRUCTURE PAGE NUMBER REVISION PV4 0 I(1) 10 AWGTMW4/THWN-2,CU.,BLACK 0.1) 9.0 AAC 1(1) 12-2 Ur--8W/G,THHN/THWN-2,SOLID Cu MAX 9.0 AAC (1) 12.2UF-8(ar NMIW/G,THIH/THWN-2,.SOL MAX 9.0 A (1) 12.2TC•EB,TMHN/THWN-2,CU. MAX 9.0 AAC 15 .(1) 10AWGTHN//TNWN-2.CU,, EDiLII 240VA,C 3 240VAC ORI2.2TC-ER,THHN/lN-2,CU.,90C 2WV )1) 6AWGRARE,CU(EGC) 240VAC !(1) 10AWGTIRW/TMWN-2,CU„WHITT(H) 2 MW 1 Niellte • a) 'TO AWGTHWITHWN.2.CU..GREEN(EGC) I (1) 3/4 INCH EMI EXTERIOR )1) 3/4 INCH EMT EXTERIOR .... ..,. , _. INTETNDR EXTERKM BLUE RAVE N 1403 N RESEARCH WAY,BUILDING J ALL CONDUIT TO BE RAN AT LEAST 7/8 IN.ABOVE ROOF SURFACE WHERE EXPOSED TO SUNLIGHT. DREM,UT 84097 800-377-4480 W W W-BLUERAV ENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT 8E USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE (E)200A MAIN SERVICE PANEL WRITTEN PERMISSION OF (E)150A!2P MAIN BREAKER (9)JinKO Solar Eagle 315W M 60CEL BLACK BLUERAVENSOLAR LLC. Enphase IQ Combiner 3 UL 1703 COMPLIANT PV AC DISCONNECT X-IQ-AM1-240-3 'JUNCTION SPLICING �' FOR WIRE SPLICING (9)Enphase IQ7 60-2-US MICRO INVERTERS (E)150A/2P NON-FUSED (SOLAR LOADS ONLY) ONLY-OPTIONAL IF UL 1741 COMPLIANT _ LOCKABLE,VISIBLE OPEN _ Q-CABLE(TC-ER)OR 9 MODULES MAX FOR ALL SUB-BRANCH NABCEP 30A,240V,2-POLE OF-B USED FOR CIRCUIT(S)TO COMPLY WITH VRISE CALCS CERTIFIED (E)LOADS — ENTIRE HOMERUN _ PV INSTALLATION a - N JUNCTION BOX JUNCTION BOX PROFESSIONAL Scott Gurney n o (N)20N2P r — (N)20MI('\ ) i (1) CIRCUIT 1111119 1111 #PV-011719-015866 d11 ° �, a /1 0 /) """"' \\\ OF 9 MODULES „' ° „` > f ! I IMO ` CONTRACTOR: RI___--02 E°° — �� I —� —I I BRS FIELD OPS 12orzao vac y — 385.498.6700 60HZ 1 PHASE TO UTILITY15GRID0 O O O 0 PV BREAKER TO BE LOCATED OPPOSITE END OF BUSSING FROM MAIN BREAKER { o (E) GROUNDING ) co ELECTRODE(S) -,: I ,"- _ I , C Qc o m N i: W INTERCONNECTION NOTES ` 0 (� a LL N O I- 1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OF ,r.. i s - + - Z it- LO >i BUSBARS AND PANELBOARDS. (a)THE SUM OF 125 PERCENT OF THE INVERTER(S)OUTPUT / , S — 0) f ____ .-.—x. W O r •V CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE a wr ) a I< F- >, CO C� BUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b)WHERE TWO SOURCES, ,, . ' (n 0 0 ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF A p 3: DRAWING BY BUSBAR THAT CONTAINS LOADS,THE SUM OF 125 PERCENT OF THE INVERTER(S)OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE - -- DIN DIN ENGINEERING BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR[NEC 705.12]. ( w, October 27, 2020 DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS _ eti „.,.'" it PROJECT NUMBER 4': OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE ,i TERMINALS MARKED"LINE SIDE(TYPICALLY THE UPPER TERMINALS) (, a # 86958235 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE "; ( SHEET NAME LOCKABLE,AND BE A VISIBLE-BREAK SWITCH 4) ELEC. 3 LINE D IAG. PAGE NUMBER REVISION Utility Company: Portland General Electric (PGE) Permit Issuer: City of Tigard PV5 0 - LABEL 1 - LABEL 7 LABEL 11 r,.. -{..' '..:.9 :.I; . NG 1 t'` 7- PERMANENT DIRECTORY TO BE LOCATED AT--. FOR PV DISCONNECTING MEANS WHERE ALL " P❑f-I Ln)Tttp,n:u AT DIRECT-CURRENT EXPOSED RACEWAYS,CABLE MAIN SERVICE EQUIPMENT LOCATION IF ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ,1Y^�ERSOURCE TRAYS,COVERS AND ENCLOSURES OF JUNCTION BOXES, I MMOIOQYOMTI3IM1IUW 0191CONIMICTS.. ELECTRICAL POWER SOURCE DISCONNECTING ELECTRIC SHOCK HAZARD ENERGIZED IN THE OPEN POSITION. AND OTHER WIRING METHODS;SPACED AT MAXIMUM RAWT41M8eUadMOgMgOdINrIED BLUE RAVEN TERMINALS ON THE LINE AND [NEC 690.13(B),NEC 705.22] 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, OA9 SWMET CH)ARE GROUP D S (SOLAR ARRAY R AND IN LINE OF APID 31TE OF WALLS,PARTITIONS,CEILINGS,OR FLOORS. pppp ryp o%moll or - LOAD SIDES MAYBE ENERGIZED MAIN SERVICE DISCONNECTING MEANS. .— IN THE.OPEN POSITION µ..., [NEC 690.31(G)(3&4)] AA°�fr�Ti�&'t7GiTgw [NEC 690.56(C)&NEC 705.10]. I SOLAR RAPID SHUTDOWN PV SYSTEM EQUIPPED OR PV SYSTEMS THAT SHUT DOWN THE ARRAY 1403 N RESEARCH WAY,BUILDING J LABEL 2 ■�� �e LABEL 12 _ OREM,UT 84097 AND CONDUCTORS LEAVING THE ARRAY: L �- PERMANENT DIRECTORY TO BE LOCATED AT )IfEURFtFT�IT SIGN TO BE LOCATED ON OR NO MORE THAN 3 800-377-4480 T - AT EACH DC DISCONNECTING MEANS,INCLUDING THE 1 TO NRO'1p`,9a. ': , - SOLAR ARRAY RAPID SHUTDOWN SWITCH P C)TsvOLTAIv I�4 "T R SOURCE DC DISCONNECT AT THE INVERTER. SWOT TO iE FT AWAY FROM SERVICE DISCONNECTING PYEORTOTNBMULOMXI IS AL80 DENOTING THE LOCATION OF THE SERVICE WWW BLUERAVENSOLAR.COM 1:7-S SWIM 10 MEANS TO WHICH THE PV SYSTEMS ARE [NEC 690.53,NEC 690.13(B)] gyq root vv prey ;�_`. � CONNECTED AND SHALL INDICATE THE SUPPUFD FROM YA1t1016T 171CH EQUIPMENT LOCATION IF SOLAR ARRAY RAPID CONFIDENTIAL-THE INFORMATION MAXIMUM VOLTAGE Vt 11TpJ1Y DISCONNECT LOCATED SHUT DOWN DISCONNECT SWITCH IS NOT LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN HEREIN CONTAINED SHALL NOT BE _ GROUPED AND WITHIN LINE OF SITE OF MAIN SWITCHES IF NOT AT THE SAME LOCATION. USED FOR THE BENEFIT OF MAX CIRCUIT CUR:RENt AMPS —•b 1�EYIRAY - SERVICE DISCONNECTING MEANS. -- ----' [NEC 690.56(C)(1)(A)] ANYONE EXCEPT [NEC 705.10] BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN LABEL 9 PART TO OTHERS OUTSIDE LABEL 3 SOLAR PV SYSTEM EQUIPPED FOR PV SYSTEMS THAT ONLY SHUT DOWN LABEL 13 RECIPIENTS ORGANIZATION, CONDUCTORS LEAVING THE ARRAY: PHOTOVOLTAIC SYSTEM AT POINT OF INTERCONNECTION,MARKED AT AC WITH RAPID SHUTDOWN 6♦ PERMANENT DIRECTORY TO BE LOCATED AT MAIN SERVICE EQUIPMENT DENOTING THE LOCATION DISCONNECTING MEANS. 1 VANA4e5 DAMON:1 AVT°1 SIGN TO BE LOCATEDCONE IS NO MORE THAN 3 EXCEPT IN CONNEC TION WITH THE rarER TO'I}Y MidN06A/805tIPRpF.D OF THE PV RAPID SHUTDOWN SYSTEM SALE AND USE OF THE RESPECTIVE 4t� Al" DISCONNECT j [NEC 690.54,NEC 690.13(B)] TOT)*c- pq �. FT AWAY FROM SERVICE DISCONNECTING mow, sex/Autism gpi/Aism DISCONNECTING MEANS IF SOLAR ARRAY RAPID EQUIPMENT,WITHOUT THE Ta Tcom:;fTo.E . �`^ k MEANS TO WHICH THE PV SYSTEMS ARE WRITTEN PERMISSION OF RATED AC OUTPUT CURRENT A } SCE7€tJWv i MAORM StiVTIXYMrD11GOMECTIS SHUT DOWN DISCONNECTSWITCH IS NOT CONNECTED AND SHALL INDICATE THE BLUERAVENSOLAR LLC. OPERATING AC WJLTAC>� - ^' iE. w'°t ,,,jaaa,,,f LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN , "CATE13°� WIT TDum,rTy 1 GROUPED AND WITHIN LINE OF SITE OF MAIN VNNIINTIE I Fls�PAPor 1U04T SWITCHES IF NOT AT THE SAME LOCATION. --- ---- ----- - SERVICE DISCONNECTING MEANS.[NEC 705.10, ,.�...._._.._ -._,„. __ r NEC 690.56(C)(1)] [NEC 690.56(C)(1)(B)] LABEL 14 NABCEP „T;n+ LABEL 4 ,. PERMANENT DIRECTORY TO BE LOCATED AT AC CERTIFIED w -_, IF INTERCONNECTING ON THE LOAD SIDE,INSTALL THIS LABEL 10 COMBINER PANEL[NEC 110.21(B)] � "',t LABEL ANYWHERE THAT IS POWERED BY BOTH THE - -. �' 's SIGN LOCATED AT RAPID SHUT DOWN PV INSTALLATION E3UAlPOWER SUPPLY AND THE SOLAR PV SYSTEM:THE MAIN SERVICE DISCONNECT SWITCH[NEC 690.56(C)(3)]. PHOTOVOLTAIC SYSTEM PROFESSIONAL PANEL AND SUB-PANELS. COMBINER PANEL SOLACES,UTILITY GROOM [NEC 705.12(6)(3)1 Scott Gurney PV SOLAR ELECTRIC SYSTEM DO NOT ADD LOADS R PV-011719-015866 CONTRACTOR: LABELING DIAGRAM FOR MICRO INV.: BRS FIELD OPS MAIN SERVICE PANEL 385.498.6700 ,� LABEL 5 EXISTING SUB PANEL PV COMBINER JI\ tt " 1;£. 1N PLACED ADJACENT TO THE BACK-FED BREAKER O 0 (IF WHERE POINT OF SUBPANEL- FROM THE INVERTER IF TIE IN CONSISTS OF LOAD INTERCONNECTION IF USED TO COMBINE AC JUNCTION BOX SIDE CONNECTION TO BUSBAR. INVERTER OUTPUT CONNECTION [NEC 705.12(B)(2)(3)(b)] IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS OR AC COMBINER BOX DO NOT RELOCATE O&OO O O O 0 El OVERCURRENT ° IF BREAKER USED "C DEVICE 0 °❑ O&04 10 0 -0 11 OR 13 IF BREAKER USED C C "". 7� i } LABEL 6 OR PLACARDO 12 OR O L CO A WARN!NG (ONLY IF 3 OR MORE SUPPLY SOURCES TO PLACARD Z N -As_) 4 7 A BUSBAR) O O 1 1 0 = N o/ _ SIGN LOCATED AT LOAD CENTER IF IT (ONLY IF PV (ONLY IF PV ,o [� W TIM5 EQUIPMENT FED BY M :_ PLE CONTAINS 3 OR MORE POWER SOURCES. INTERCONNECTION NTERCONNECTIOP — °� ° Vj Q0 N SOURCES.TOTAL RATING OF W L [NEC 705.12(B)(2)(3)(C)] CONSISTS OF LOAD CONSISTS OF LOAD 14 Q C 0) C U) OVERCURRENT DEVICES,EXCLUDNG SIDE BREAKER) SIDE BREAKER) c6 O cc E J` MAIN SLJPPLY OVERCURRENT 0 NS. N W DE.'ICE.SHALL NOT EXCEED LABELING DIAGRAM FOR STRING INV.I DC OPTIMIZER INV.: Z 0 AMFACITY OF BUSBAR. MAIN SERVICE PANEL _ 0) -O ›- 0 EXISTING SUB PANEL PV COMBINER INVERTER(S) W O - of (I) (IF WHERE POINT OF SUBPANEL- � Oo 0 a_) 0 O&O INTERCONNECTION IF USED TO COMBINE (I) - (] IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS IF BREAKER USED - DRAWING AY ° ° 0 O 0 DIN ENGINEERING °°° oQRo O&O 3 O DATE 0 OR 13 IF BREAKER USED Ac JUNCTION BOX October 27, 2020 OR PLACARD 12 OR 2 'I LABELING1. A BELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO 5 O P CARD 10 oc OR COMBINER BOX PROJECT NUMBER DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND (ONLY IF PV (ONLY IF PV O 7 86958235 MAKE APPROPRIATE ADJUSTMENTS. INTERCONNECTION NTERCONNECTION °� ° O 10 1 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE,OSHA STANDARD CONSISTS OF LOAD %ONSISTS OF LOAD Ix,: 7 19010.145,ANSI Z535. SIDE BREAKER) SIDE BREAKER) O O O SHEET NAME 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. - LABELS 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND INTEGRATED DC DISCONNECT SHALL NOT BE HANDWRITTEN[NEC 110.21] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8",WHITE ON RED BACKGROUND;REFLECTIVE, 'ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PAGE NUMBER REVISION AND PERMANENTLY AFFIXED[IFC 605.11.1.1] PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. PV8 0 • • \Or' Data Sheet Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters BLUE INPUT DATA(DC) 107-60-2-US IO7PLUS-72-2-US RAVEN - Region:AMERICAS __ Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell/120 halt-cell PV module. 60-cell/120 half-cell and 72- only cell/144 half-cell PV modules 1403 N RESEARCH WAY,BUILDING J Maximum input DC voltage 48 V 60 V OREM,UT 84097 Peak power tracking voltage 27 V-37 V 27 V-45 V 800-377-4480 - -- Operating range 16 V-48 V 16 V-60 V VWWV.BLUERAVENSOLAR COM Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit Current(module Isc 15 A 15 A CONFIDENTIAL-THE INFORMATION Enphase The high-powered smart grid-ready ) HEREIN CONTAINED SHALL NOT BE Oeervoltage class DC port II II USED FOR THE BENEFIT OF Enphase IQ7MicrcTNM1and irtphaseIQ7+ MicroTM ANYONE EXCEPT BLUE RAVEN DC port backfeed current OA 0 A SOLAR NOR SHALL IT BE IQ 7 and IQ 7+ dramatically simplify the installation process while PV array configuration 1 x 1 ungrounded array;No addi onal DC side protection required; DISCLOSED IN WHOLE OR IN PART AC side protection requires marQOA per branch circuit TO OTHERS OUTSIDE RECIPIENTS Mi c ro inverters achieving the highest system efficiency. OUTPUT DATA(AC) 107 Microinverter 107+Microinverter ORGANIZATION,EXCEPT IN Part of the Enphase IQ System,the IQ 7 and Peak output power 250 VA 295 VA CONNECTIO USE OFITHETH AND RE THE Maximum continuous output power 240 VA 290 VA EQUIPMENT,WITHOUT THE IQ7+Microinverters integrate with the Enphase Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208V/ WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. IQ EnvoyTM Enphase IQ BatteryTMand the Enphase 211-264 V 183.229V 211 264 V 183-229V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V 1.21 A(240 V) 1.39 A(208 V) Enlighten' monitoring and analysis software. Nominal frequency 60Hz 60Hz NABCEP IQ Series Microinverters extend the reliability Extended frequency range 47-68 Hz 47-68 Hz CERTIFIED AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms• standards set forth by previous generations and Maximum units per 20 A(L-L)branch circuit° 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) PV INSTALLATION undergo over a million hours of power-on testing, O✓ervoltage class ACport Ill III PROFESSIONAL AC port backfeed current 18 mA 18 mA Scott Gurney enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 #PV-011719-015866 warranty of up to 25 years. Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging CONTRACTOR: EFFICIENCY ©240 V ©208 V ©240 V ©208 V BRS FIELD OPS Peak efficiency 97.6% 97.6% 97.5% 97.3% 385.498.6700 CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Easy to Install Relative humidity range 4%to 100%(condensing) Connector type MC4(or Amphenol H4 hEX with additional Q-DCC-5 adapter) • Lightweight and simple Dimensions(HxVVxD) 212 mm x 175 mm x 30.2 mm(without bracket) • Faster installation with improved,lighter two-wire cabling Weight 1.08 kg(2.381bs) • Built-in rapid shutdown compliant(NEC 2014&2017) Cooling Natural convection-No fans Approved for wet locations Yes 10 Pollution degree PD3 , - Productive and Reliable Enclosure Class II double-insulated,corrosion resistant polymeric enclosure • Optimized for high powered 60-cell/120 half-cell and 72- Environmental category/UV exposure rating NEMA Type 6/outdoor mommos cell/144 half cell*modules FEATURES • More than a million hours of testing Communication Power Line Communication(PLC) • Gass I Idouble-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. - • UL listed Disconnecting means The AC and DC connectors have been evaluated and approved byUL for use as the load-break disconnect required by NE-C 690. Smart raid Read Compliance CA FDle 21 (UL 1741-SA) IC Smart UL 62109-1,UL1741/IE EE1547,FCC Part 15 Class B, ICES-0003 Class B, F 1I • Complies with advanced grid support,voltage and TAN product is UNO.Listed 1-1 Rapid Shut Down pp Equipment and conforms with NEC 2014,NEC frequency ride-through requirements 2017,and NEC2020 section 690.12 and C22.1-2015 Rile 64-218 Rapid Shutdown of PV Systems, • Remotely updates to respond to changing for AC and DC conductors,when installed according manufacturer's instructions. grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) 0 •The 107+Micro is required to support 72-cel l/144 half-cell modules. 1.No enforced DC/AC ratio.Seethe compatibility calculator at htt05//enohase.com/en-us/su000rt/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. cEk1n ED 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. SHEET NAME ENPHASE. To learn more about Enphase offerings,visit enphase.com ENPHASE. SPEC SHEET To learn more about Enphase offerings,visit enphase.com V `/ ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7,Enphase IQ 7+,Enphase IQ Battery, Enphase Enlighten,Enphase IQ Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change 2020-08-12 PAGE NUMBER REVISION SS 0 • '. Data Sheet Enphase IQ Combiner 3 -Enphase Networking MODEL NUMBER IQ Combinar 3 IQ Combiner 3 with Enphasee IQ lQ EnvoyT"printed circuit board for Integrated revenue grade PV BLUE RAVEN X-IQ-AM1-240-3 production metering(ANSI C12.20+1-0.5%)and optional*consumption monitoring(+/-2.5%). ACCESSORIES and REPLACEM ENT PARTS(not included,order separately) Enphase Mobile Connect' 1403 N RESEARCH WAY,BUILDING J CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 OREM,UT 84097 CELLMODEM-01 (3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1(4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) 800-377 aaao V W VW.B L U E RA V E N S 0 LA R.corm C,, Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2.5%). Enphase The Enphase IQ Combiner 3Tmwith Enphase CT-200-SPLIT CONFIDENTIAL-THE INFORMATION *Consumption monitoring is required for Enphase Storage Systems HEREIN CONTAINED SHALL NOT BE TUSED FOR THE BENEFIT OF I C� Combiner 3 IQvoy N'bonsolidates interconnection Wireless USB adapter Installed at the IQ Envoy.For communications with Enphase Encharge"storage and Enphase ANvoNE EXCEPT BLUE RAVEN COMMS-KIT-01 Enpower"smart switch.Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner'" SOLAR NOR SHALL IT BE equipment into a single enclosure and and allows redundant wireless communication with Encharge and Enpower. DISCLOSED IN WHOLE OR IN PART Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. TO OTHERS OUTSIDE RECIPIENTS (X-IQ-AM 1-240-3) streamlines PV and storage installations by BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 ORGANIZATION,EXCEPT IN BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 CONNECTION WITH THE SALE AND BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 USE OF THE RESPECTIVE providing a consistent,pre-wired solution for EQUIPMENT,WITHOUT THE EPLO-01 Power line carrier(communication bridge pair),quantity-one pair WRITTEN PERMISSION OF BLUE residential applications. It offers up to four RAVEN SOLAR LLC. PP P XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for[PLC-01) 2-pole input circuits and Eaton BR series XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS NABC'EP busbar assembly. CERTIFIED Rating Continuous duty System voltage 120/240 VAC,60 Hz PV INSTALLATION Eaton BR series busbar rating 125 A PROFESSIONAL Gurney Scott Max.continuous current rating(output to grid) 65 A ItPv-o1171s 015888 Max.fuse/circuit rating(output) 90 A CONTRACTOR: Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) BRS FIELD OPS 385.498.6700 Smart Max.continuous current rating(input from PV) 64 A `e Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included I • Includes IQ Envoy f or communication and control Production Metering CT 200 A solid core pre-installed and wired to IQEnvoy • Flexible networking supports Wi-F, MECHANICAL DATA 1 L' ,I ' I • 4 Ethernet,or cellular Dimensions(WxHxD) 49.5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets). i '. • Optional AC receptacle available for PLC Weight 7.5 kg(16.5 Ibs) bridge a , Ambient temperature range -40°C to+46°C(-40°to 115°F) • Provides production metering and optional ' 4 ,.+ consumption monitoring Cooling Natural convection,plus heat shield 3 Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction rt Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors ( Simple • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output 10 to 2/0 AWG copper conductors ) I • Reduced size from previous combiner • Neutral and ground 14 to 1/0 copper conductors • Always follow local code requirements for conductor sizing. Centered mounting brackets support single Altitude To 2000 meters(6,560 feet) L> .t r' ° ° stud mounting INTERN ET CONNECTION OPTIONS • Supports back and side conduit entry Integrated M Fl 802.11 b/g/n • Up to four 2-polebranch circuits for 240VAC plug-in breakers(not included) Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) "'— - " • 80 A total PV or storage branch circuits Cellular Optional,CELLMODEM-01 (3G)or CELLMODEM-03(4G)or CELLMODEM-M1(4G based LTE-M) (not included) COMPLIANCE Reliable Compliance,Combiner UL 1741, CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class 8,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) • Durable NRTL-certified NEMA type Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 3R enclosure ICIPO • Five-year limited warranty • UL listed To learn more about Enphase offerings,visit enphase.com SHEET NAME LISTED ©2018 Enphase Energy.Al rights reserved.Enphase,the Enphase logo,IQ Combiner 3,and other trademarks or service names are the SPEC SHEET '—� EN P H rks°' phase Energy,Inc. E N P H AS E. To learn more about Enphase offerings,visit enphase.com `r� �4 '''' PAGE NUMBER REVISION SS 0 Lotal oe _jinKO Engineering Drawings Electrical Performance&Temperature Dependence` N jinkosolar.us ■`_., BLUE RAVEN C,r;c Your Trust, .Ft,,,... I I I I I I I I(I I I I I I I I I(I I I I I I I I I ��°a III ` Current-Voltage JPover-Voltage Temperature atU,e Dependence • Illf 11111 11111/1111 t I I II I.I l l l l l l l ll l II(I I rI r 1403 N RESEARCH WAY,BUILDING J 11111111(I11111111(1I11(1III ��1...� OREM,UT 84097 ww s� III11111(I II1H11I11111III It a IIIIII. Eagle /����/ •� ,asa +e 800.377-4480 �� ,N/ f�f� (/►.A) IIIfJIl111I11111111111f1111 C HC �Ytr W■ VL. m v! illlllll(IIIIIIII(IIII(IIII T + --""- - �� vwwo.BLUERAVENSOLARCOM °I IIII I III 1111( WIRIE b �\+� /(� w/�� III�,IIIIIIIII i lllllll(Illlf �. < amp >+m25' 11'n = CONFIDENTIAL-THE INFORMATION 3 5 335 f f �a*�� (IIII�IIIIIIIII���IIIII • 1p II.,�� HEREIN CONTAINED SHALL NOT BE I(IIIIrI I11 IIIITII((I11111 ��� 'S0= _ ���� USED FOR THE BENEFIT OF MONO PERC HALF CELL MODULE ) nnlllll Illll llllllllll „�_ E • �/ + E -m ANYONE EXCEPT BLUE RAVEN 11111IIIIr1111111111I111(IIIIf �E' //� z MEM= SOLAR NOR SHALL IT BE 1111111111111(111111111(11111 1111 m i 5o a i �IIIIIIIIIIIHIr ,, �..■■ DISCLOSED IN WHOLE OR IN PART Positive power tolerance of 0-+3 0 , l l 11 HMI,I I N I II I I I I I I I I I 111( o s +o +s :o ks oo as w ss TO OTHERS OUTSIDE RECIPIENTS t o —_ o � ■■MI ORGANIZATION,EXCEPT IN - o e5 m Ye +oo CONNECTION WITH THE SALE AND runt Bide sect voltage(V) den Temp„mYfem USE OF THE RESPECTIVE I. ! EQUIPMENT,WITHOUT THE 1:, (mmmlallrmlr WRITTEN PERMISSION OF BLUE ' • - - RAVEN SOLAR LLC. a 1.> ° +: I ® "" Cell Type Mono PERC Diamond Cell(158.75 x 158.75 mm) - '- 5 .. No.of Halt ce it 120(6x20) I - _ NABCEP _ x i • 1-� _ Dimensions -_.. 1684x1002o35mm-(66.30x39.95x1.38 inch)..._ KEY FEATURES r m Weight 190kg(4191bs) CERTIFIED Front Glass 3.2mm,Anti-Reflection Coating, PVINSTALLATION High Transmission,Low Iron,Tempered Glass " ' Frame Anodized Aluminum Alloy PROFESSIONAL Packaging Configuration r saattGamey 111111 Diamond Cell Technology Two pallets=One stack) Junction Box 1P67 Rated !t PV-011719-015886 „"" Uniquely designed high performance 5 busbor mono PERC half cell 30pcs/patlet,"bO(itS75[adc 7`80pds/46'HQ Container Output Cables 12AWG,Anode 1525mm(6004 in), • Cathode 1525mm(60.04 in)or Customized Length CONTRACTOR: Fire Type Type 1 BRS FIELD OPS F. Higher Module Power 385.498.6700 • Decrease in current loss yields higher module efficiency i. SPECIFICATIONS Shade Tolerance Module Type JKM315M-6OHL JKM320M-6OHL JKM325M-6OHL JKM33OM 6OHL JKM335M 6OHL «- µ _ a More shade tolerance due to twin arrays STC NOCT SIC NOCT SIC NOCT STC NOCT SIC NOCT Maximum Power(Pmax) 315Wp 235Wp 320Wp 239Wp 325Wp 242Wp 330Wp 246Wp 335Wp 250Wp PID FREE Maximum Power Voltage(Vmp) 33.2V 31.2V 33.4V 31.4V 33.6V 31.6V 33.8V 31.8y 34.0V 32.DV ;a4 • n°-xee Reinforced cell prevents potential induced degradation Maximum Power Current(Imp) 9.49A 7.56A 9.59A 7 62A 9.68A 7.66A 9 77A 7 74A 9.87A 7.82A Open-circuit Voltage(Voc) 40.7V 37.6V 40.9V 37.BV 41.1V 38.OV 41.3V 38.2V 41.5V 38.4V '7;",�°� k ti# Short-circuit Current(Isc) 10.04A 8.33A 10.15A 8.44A 10.20A 8.54A 10.31A 8 65A 10.36A B.74A Strength and Durability wma Module Efficiency STC(%) 18.67% 18.96% 19.26% 19.56% 19.85% . —az, Certified for high snow(5400Pa)and wind(2400 Pa)loads - .. Operating Temperature(°C) -40'C'*85°C Maximum System Voltage 1000VDC(UL)/1000VDC(IEC) Maximum Series Fuse Rating 20A Power Tolerance 0—+3% I;: ... '...... • IS09001:2008 Quality Standards • lSOI4001 2004 Environmental Standards Temperature Coefficients of Pmax -0 36%PC • OHSAS18001 Occupational Health 8 Safety standards Temperature Coefficients of Voc -0.28%/°C `.a `'2°fit+ ems 51 • 1E061215,1E061730 certified products LINEAR PERFORMANCE WARRANTY Temperature Coefficients of lsc 0048%PC • UL1703 certified products 10 Year Product Warranty •25 Year Linear Power Warranty Nominal Operating Cell Temperature (NOCT) 45±2°C ,�a>, S N �t W Nomenaature: JKM335M-8OHBL .. , .°..° rrr EP Linear performance warranty Code Cell Code Backsheel Code Cell a IOWA nue Fun null IMne non Normal c vnc Aaa/g Standard performance warranty STC: :J Irradiance 1000W/ms # Cell Temperature 25°C AM=1.5 H Hell B Black L Diamond 90T. no/yore from Jloko gabrs g V� US I EC cE 8 ,,, e�Worrom, NOCT ti4cIrradiance 800W/m2 IS Ambient Temperature 20°C 4 AM=1.5 F Wind Speed lm/s LISTED o eazx per. • Power measurement tolerance:±3% 0 a I 5 v PS yEars SHEET NAME SPEC SHEET CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. PAGE NUMBER REVISION Jinko Solar Co., Ltd. All rights reserved. Specifications included in this datasheet are subject to change without notice. SS 0 JKM315-335M-6OHL-A1-US �7�7 ' 1 Eul.N BLUE RAVEN PoweringBusiness Worldwide Pe.eaton corn 1220 S 630 E STE 430 AMERICAN FORK,UT 64003 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE {� p DISCLOSED IN WHOLE OR IN PART Eaton general duty non-fusible OOTHERIZATIO ,ERECIPI RECIPIENTS -�[ CONNECTION WIOTH EXCEPT SALE AND safety switch USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE DG221UGB RAVEN SOLAR L OF BLUE UPC:782113120102 /ABCEP Dimensions: • Height: 10.69 IN CERTIFIED • Length: 6.88 IN PV INSTALLATION • Width: 6.38 IN PROFESSIONAL ott Gumey #PV-011719-015866 Weight:6 LB CONTRACTOR: Notes:WARNING! Switch is not approved for BRS FIELD OPS service entrance unless a neutral kit is installed- 385.498 6700 Warranties: • Eaton Selling Policy 25-000. one (1) year from the dale of installation of the Product or eighteen (18) months from the date of shipment of the Product. whichever occurs first, Specifications: • Type: Non-fusible, single-throw • Amperage Rating: 30A • Enclosure: NEMA 1, Indoor • Enclosure Material: Painted steel • Fuse Configuration: Non-fusible • Number Of Poles: Two-pole • Number Of Wires:. Two-wire • Product Category: General duty safety switch • Voltage Rating: 240V Supporting documents: • Eatons Volume 2-Commercial Distribution • Eaton Specification Sheet - DG221UGB Certifications: • UL Listed Product compliance: No Data SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0 ecBLUE RAVEN FLASHED PV ROOF-MOUNT COMBINER/ENCLOSURE ;`.,, 1403 N RESEARCH-WAY,BUILDING J .'' OREM.UT 54097 Basic Features 800-377-4480 • Stamped Seamless Construction WWW.BLUERAVENSOLAR-COM • 18 Gauge Galvanized Steel y` CONFIDENTIAL-THE INFORMATION • Powder Coated Surfaces ' HEREIN CONTAINED SHALL NOT BE orr t OF Flashes into the roof deck r USEDFOR EXCEPT P BLUE IT„ - ANYONE BLUE RAVEN p - rz SOLAR NOR SHALL IT BE • 3 Roof deck knockouts .5„, ,75rr, 1" ` DISCLOSED IN WHOLE OR IN PART • 5 Centering dimples for entry/exit TO OTHERS OUTSIDE RECIPIENTS p N "" '� ORGANIZATION,EXCEPT IN fittings or conduit CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE • 2 Position Ground lug installed EQUIPMENT,WITHOUT THE EN • Mounting Hardware Included WRITT RAVEN SOLARN OF BLUE SoloDeck Model SD 0783 NABCEP SolaDeck UL50 Type 3R Enclosures CERTIFIED PV INSTALLATION Available Models: PROFESSIONAL Model SD 0783-(3"fixed Din Rail) Scott Gurney Model SD 0786-(6"slotted Din Rail) o PV-011719-015866 c.e< CONTRACTOR: BRS FIELD OPS 385.498.6700 SolaDeck UL 1741 Combiner/Enclosures Models SD 0783-41 and SD 0786-41 are labeled and ETL listed UL ST0 1741 according to the UL STD 1741 for photovoltaic combiner enclosures. Max Rated-600VDC, 120AMPS . ` Model SD 0783-41 3"Fixed Din Rail fastened using Norlock System "Typical System Configuration 4-Din Rail Mounted Fuse Holders 600VDC 30 AMP 1-Power Distribution Block 600VDC 175AMP 1-Bus Bar with UL lug Model SD 0786-41 6°Slotted Din Rail fastened using steel studs "Typical System Configuration 4-Din Rail Mounted Fuse Holders 600VDC 30 AMP 4-Din Rad Mounted Terminal Blocks Bus Bars with UL lug "fuse holders and terminal blocks added in the field mint be UL listed w recognized and meet 600 UDC'VAMP l tau 11 OC for fuse holders,800V 59 AMP 90C for rail mounted terminal blofses and 600 V 175 AMP 90C for Power Distribution Bk+rltS Use Copper Wire Conductors f Cover re iri ,to allow Model S0 0783-41 wired with Model SD 0786-41,wired with conduit or fittings.base is Den Rad mounted fuse holders, Din Rail mounted fuse holders, center dimpled for-fitting bus bar and power distrtbulion terminal bloom and bus bars, locations, block SHEET NAME RSTC Enterprises. Inc • 2219 Neimstead Road •Eau Cliare, Wi 54703 SPEC SHEET For product information call 1(866) 367-7782 PAGE NJMBER REVISION SS 0 . . ■ ■ SUN ' BLUE RAVEN ■�� . sFm FRAME ■M MICRORAILTM INSTALLATION GUIDE : PAGE 1403NREOREMCUTV84097UILDINGJ 800-377-4480 = a'______ i___��' R __ rmi4 __— u ' _- WWW.BLUERAVENSOIAR.COM T CONFIDENTIAL-THE INFORMATION OM". HEREIN CONTAINED SHALL NOT BE' ll - USED FOR THE BENEFIT OF • 0 ANYONESOLAR NOR SHALL T REEN mil .III DISCLOSED IN WHOLE OR IN PART - TO OTHERS OUTSIDE RECIPIENTS w„ ORGANIZATION EXCEPT IN Ilir '. CONUSE OF T E RESPE STIVEAND —_ --- — —_ _-- -- __ .- `• EQUIPMENT WITHOUT THE W E i �j WRITTEN PERMISSION OF BLUE ' -- RAVEN SOLAR LLC. c NABCEP CERTIFIED w- _ __ _ ___ __ __ ___ _ ME PV INSTALLATION � -- — um E-W BONDING PATH: PROFESSIONAL E-W module to module bondingis accomplished Scott Gurney P #PV-011719-015866 III • with 2 pre-installed bonding pins which engage CONTRACTOR EP ■ : Jill the secure side of the MicrorailTM and splice. BRS HELD OPS - `'MEM 385 498 6700 IIIII II I 40 Star I/Vas_, .r !s WEEBLUG Singie Use Only Single Use Or I N-S BONDING PATH: TERMINAL TOR E. N-S module to module bonding is Install Cora-it.' ; a-d accomplished with bonding clamp with 2 integral torque to the. 1s ;-N,, lc 1=LHI,rlN, TERVINALTCGRi. . bonding pins. a 6 AWG: 3S0, ,t s nstal C: Install Co,dk.s AWG 25to-1:1s torrtue'_. orquetothe'�r i-14AWCz 'c , 'L5 -14AGV,." t)-14AWG 7 t •0 LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO LUG DETAIL& TORQUE INFO ... Ilsco Lay-In Lug (G3L--4DBT) Ilsco Range Lug(S( -4) WileyWEEBLug (6.7) ..-'--- • 10-32 mounting hardware • 1/4" mounting hardware • 1/4" mounting hardware — .... � — • Torque = 5 ft-lb • Torque = 75 in-lb • Torque = 10 ft-lb Alternate rretnod _ • AWG 4-14-Solid or Stranded • AWG 4-14-Solid or Stranded • AWG 6-14-Solid or Stranded TRIM RAIL BONDING PATH: NOTE ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION Trimrail to module bonding is accomplished with stem bondingisaceom accomplished through modules. groundingaccomplished byattachingbondingclamp with integral bondingpin and SHEET NAME 9�r ' p ' g Sistem p ' 9 SPEC SHEET a ground lug to any module at a location on the module specified by the module manufacturer. bonding T bolt. PAGE NUMBER REVISION SS 0 Nkhor- NOTES ! 1 ®O : SUN BLUE RAVEN ■ 11111 : sFm FRAME ■ ■ i MICRORAILTM INSTALLATION GUIDE 1. PAGE 1403 N RESEARCUTy840,BUILDING) OREM,800-377-4480 SYSTEM LEVEL R RE CLASSFl C4TI ON VNNWBLUERAVENSOLAR COM CONFIDENTIAL-THE INFORMATION The system fire class ratingrequires installation in the manner specified in theperformance is inherent in the SFM design,and no additional mitigation measures HEREIN CONTAINED SHALL NOT BE Y q P 9 9 USED FOR THE BENEFIT OF SUNFRAME MICRORAIL (SFM) Installation Guide. SFM has been classified to are required.The fire classification ratingis valid for anyroof pitch.There is no ANYONE EXCEPT BLUE RAVEN q SOLAR NOR SHALL IT BE the system level fire portion of UL 1703. This UL 1703 classification has been required minimum or maximum height limitation above the roof deck to maintain DISCLOSED IOUNTSDE RECIPIENTS incorporated into the UL 2703 product certification. SFM has achieved Class A, the Class A, B & C fire rating for SFM. SUNFRAME MICRORAI LTM components shall CONNECT ONTION WITH EXCEPT THE EAND B & C system level performance for low slope & steep sloped roofs when used be mounted over a fire resistant roof covering rated for the application. USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE in conjunction with type 1 and type 2 modules. CLass A, B & C system level fire WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. Module Type Fbof Slope System Level Fire Rating Microrail Direction Module Orientation Mitigation Flaquired NABCEP Type 1 and Type 2 Steep Slope & Low Slope Class A, B& C East-West Landscape OR Portrait None Flequired CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney UL2703 TIzSI MODULES #PV-01m9-o1sB66 See page "S"for a list of modules that were electrically and mechanically tested /`O CONTRACTOR: BRS FIELD OPS or qualified with the SUNFRAME MICRORAIL (SFM) components outlined within ; 385.498.6700 this Installation Guide. = ' • Maximum Area of Module = 22.3 sgft • UL2703 Design Load Ratings: 11,0 a) Downward Pressure - 113 PSF / 5400 Pa :' ;:i, `III. b) Upward Pressure - 50 PSF / 2400 Pa -). ��� c) Down-Slope Load - 30 PSF / 1400 Pa \, ..,7 =!G • Tested Loads: �' a) Downward Pressure - 170 PSF/ 8000 Pa / / -:,) b) Upward Pressure - 75 PSF / 3500 Pa \ > c) Down-Slope Load - 45 PSF / 2100 Pa • Maximum Span = 6ft • Use with a maximum over current protection device OCPD of 30A • System conforms to UL Std 2703, certified to LTR AE-001-2012 • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span LABEL MARKINGS • System fire class rating: See installation instructions for installation requirements to achieve a specified system fire class rating with Unirac . 3 ,>c. LYVVnio=It Id=,. --�-�- i--1 '.-: ;"aHlad�Cm 30[WS y Z 6LiT ,,titiM • Unirac SUNFRAME MICRORAILT"^ is listed to UL 2703. ww�, t.... �m..,4g J. , SHEET NAME • All splices within a system are shipped with marking indicating date SPEC SHEET and location of manufacture. , $ 1 3 1 1 a t t = 1 -.. .- PAGE NUMBER REVISION SS 0 ■ ■ 1 SUN ; s Nti,..., BLUE RAVEN ONOsFm FRAME • ■. ICRORAILTM INSTALLATIIIN GUIDE ; PAGE 1403NREOOREM,UTW84977 UILDINGJ 800-377-4480 W W W.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION Manufacture Module Model / Series Manufacture Module Model / Series Manufacture Module Model I Series HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN i Aleo P-Series PEAK Energy Series, DISCLOSED NNOWR HO EL ORIT NE PART JAP6 60 xxx,JAM6 60 xxx/SI,JAM6(K) 60/ TO OTHERS OUTSIDE RECIPIENTS CHSM6612P,CHSM6612P/HV,0HSM6612M, xxx,JAP6(k)-72-xxx/4BB,JAP725YY-xxx/ZZ, PEAK Energy BLK2 Series, ORGANIZATION,EXCEPT IN PEAK Energy72 Series, CONNECTION WITH THE SALE AND Astronergy CHSM6612M/HV,CHSM661OM (BL)(BF)/(HF), JAP6(k)-60-xxx/4BB,JAP6OSYY-xxx/ZZ, REC USE OF THE RESPECTIVE CHSM72M-HC J4SDIar 1AM6(k) 72 xxx/ZZ,JAM725YY-xxx/ZZ, TwinPeak WRITTEN Series, EQUIPMENT,PERMISSION PS THE I OUOSION OF BLUE -60 xxx/ZZ,JAM605YY-xxx/ZZ. TwinPeak 2 BLK2 Series, RAVEN SOLAR LLC JAM AXN6M610T,AXN6P610T, O Auxin i.YY:01,02,03,09,10 TwinPeak Series AXN6M612T& AXN6P612T NABCEP ii.ZZ:Sc.PR,BP,HiT,IB,MW Fbnesola Vitrus2 Series& 156 Series Axitec AXI Power,AXI R'emi um,MI Black Premium Rsen RSMSeries CERTIFIED Boviet BVM6610,BVM6612 Jnko J(M& JCMSSeries PV INSTALLATION S-Energy SN72 &SN60 Series(40mm) PROFESSIONAL BYD P6K& MHK 36 Series Kyocera KU Series Scott Gurney Seraphim SEG-6& SRP-6 Series a PV-011719-015886 CS6 V M,CS6P-P,CS6K M,CSSA M, LG xxx S1 GAS,LG xxx N 1 GA5, LGxxxQ1C(Q1K)-ASLGxxxN1C(N1K) A5 Sharp NU-SA& NU-SC Series CONTRACTOR: CS6K MS,C36U-P,CS6U-M,CS6X P,CS6K , ,MS BRS FIELD OPS CS6K M,CSSK P,CS6P-P,CS6P-M,CS3U-P, LGxxxS1 CA5, LGxxxA1 GA5,LGxxxN2T--A4, Silfab SLA, SLG& BC Series 385.498.6700 Canadian Solar Solaria WwerXT CS3U-MS,MIK P,MIK MS,CS1 K MS,CS3K, LGxxxN2T A5,LGkxxN2W A5 LG Electronics CEGU,CS3U-MB-AG,CS3K MB-AG,CS6K, LQoocS2l/�FAS,LGxxxE1 GAS,LGxxxS2W-G4 Sunmodule Protect, Sol arWorld CS6U,CS3L,CS3Vk CS1 H-MS,CS1 U-MS LGxxxN1C(N1K)-G4,LGxxxN2W-G4, Sunmodule PI us LO xxS1 GG4,LGxxxE1 K A5,LGxxxN2T--J5, Sonali SS 230-265 Centrosolar America GSeries& E-Series LGxxxN1KN1C-VS,LGxxx 1CN2 -V5, ( ) Q ( Suntech STP CT2xxMxx-01,CT2xxPxx-01, LR6-60& LR6 72 Series, Suniva MV Series & Optimus Series CertainTeed CTxxxMxx-02,CTxxxM-03, LONG LR4-60& LR4-72 Series Sun Edison/Flextronics F-Series,R-Series& FLEX F7(S Seri es CTxxxMxx-04,CTxxxHC11-04 Mission Solar Energy MSESeries SunPower X Series,ESeries& P-Series Dehui DH-60M Mitsubishi M,E& MLE Sari es TF572,TP596,TP654,TP660, Eoo Solargy Orion 1000& Apollo 1000 Talesun Neo Solar Power Co. D6M& D6P Series TP672,Hipor M,Smart FreeVolt Mono PEFC 1 GCL GCL P6& GCL M6 Series VBHNxxxSA15& SA16, Tesl a SC,90 B,SC B1,SC B2 VBHNxxxSA17& SA18, PA05,PD05,0D05,DE06,DD06,PE06, TD-AN3,TD-AN4, Trina Hansol VBHNxxxSA17(E/G) &SA18E, PD14,PE14,DD14,DE14,DE15,PE15H UB-AN1,UD-AN1 Panasonic VBHNxxxKA01 & KA03& KA04, Upsolar UP-MxxxP(-B),UP-MxxxM(-B) ' Heliene 36M,60M,60P,,72M& 72PSeries VBHNxxxZA01,VBHNxxxZA02, URE D7MxxxHBA,D7KxxxHBA,D7MxxxH7A HT60-156(M)(NDV)(-F), VBHNxxxZA03,VBHNxxxZA04 HT Solar Vikram Eldora,Solivo,Somera HT 72-156(M/P) Hyundai KGMC�TC�RI,FC3TI,MI,HI & KI Series Pei mar SGxxxM (FB/BF) Waaree PC& Adiya Series Phono Solar PS-60,PS72 Winaico WST& WSP Seri es ITEK iT,iT-HE& iT-SESeries Japan Solar ,PS60& .PS-72 Series Q.Cells Plus,Pro,Peak,G3,G4,G5,G6(+),G7,G8(+) Vingli YGE& YLM Series Pro,Flak L( ,L G4,L G5,L(,L G7 SHEET NAME SPEC SHEET Please see the SFM UL2703Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM. SFM Infinity is not compatible with module frame height of less than 32mm and more than 40mm. See page J for further information. PAGE NUMBER REVISION SS 0 • .Intertek AUTHORIZATION TO MARK Intertek AUTHORIZATION TO MARK BLUE RAVEN Total Quality.Assured. Total Quality.Assured. 1403 N RESEARCH WAY.BUILDING J OREM,UT 84097 This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing 800-377-4480 WWW.BLUERAVENSOLAR.COM Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. Report. CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be ANYONE EXCEPT BLUE RAVEN applied only at the location of the Party Authorized To Apply Mark. applied only at the location of the Party Authorized To Apply Mark. SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN Applicant: Unirac, Inc Manufacturer: Applicant: Unirac, Inc Manufacturer: CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF BLUE Address: 1411 Broadway Blvd NE Address: Address: 1411 Broadway Blvd NE Address: RAVEN SOLAR LLC. Albuquerque, NM 87102 Albuquerque, NM 87102 Country: USA Country: Country: USA Country: /'BCEP Klaus Nicolaedis Klaus Nicolaedis • Contact: Todd Ganshaw Contact: Contact: Todd Ganshaw Contact: CERTIFIED 505-462-2190 505-462-2190 PV INSTALLATION Phone: Phone: Phone: Phone: 505-843-1418 505-843-1418 PROFESSIONAL FAX: NA FAX: FAX: NA FAX: Scott Gurney #PV-011719-015868 klaus.nicolaedis@unirac.com klaus.nicolaedis@unirac.com Email: toddgI unirac.com Email: Email: toddg©unirac.com Email: CONTRACTOR: Party Authorized To Apply Mark: Same as Manufacturer Party Authorized To Apply Mark: Same as Manufacturer BRS FIELD OPS 385.498.6700 Report Issuing Office: Lake Forest, CA _ Report Issuing Office: Lake Forest, CA Control Number: 5003705 Authorized by: Cica4,441 jqr f& Control Number: 5003705 Authorized by: C,A.04:_ist,eachtrin; for L. Matthew Snyder, Certification Manager for L. Matthew Snyder, Certification Manager CTLJSCtlJS COUS <lareo Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client_Interteks responsibility and liability are This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client Intertek's responsibility and liability are limited to the terns and conditions of the agreement.Intertek assumes no liability to any party.other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is restricted to the Conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Standard(s): Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1] Standard(s): Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed.1] • Photovoltaic Module Racking Systems[CSA LTR AE-001:2012 Ed.2012/10/23] Photovoltaic Module Racking Systems[CSA LTR AE-001:2012 Ed.2012/10/23] Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB202OMAY04 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2020MAY04 Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM SHEET NAME ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued:2-Jun-2020 ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued: 2-Jun-2020 SPEC SHEET ED 16.3.15(20-Apr-17)Mandatory ED 16.3.15(20-Apr-17)Mandatory PAGE NUMBER RFV:SICN SS 0 • all i/J ` _ 'E BLUE RAVEN . ... MOO 3 �� � 1403 N RESEARCH WAY,BUILDING J 11/ IL11�ry� INSTALLATION GUIDE PAGE OREM,UT 84097 II " OR 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE ON ..44 4%.0 0..1 i p-1 14.)•0 0...pri Nilw." - -....... a HEREIN CONTAINED SHALL R NOT I BE O INSTALL SLIDERS AND USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN ROOF ATTACHMENTS: SOLAR NOR SHALL IT BE UP- DISCLOSED DISCLOSED IN WHOLE OR IN PART : AV. Al ,<-- Follow manufacturer instructions SLOPE TO OTHERS OUTSIDE RECIPIENTS / ORGANIZATION,EXCEPT IN ! �. for flashing installation procedures CONNECTION WITH THE SALE AND ��'� III USE OF THE RESPECTIVE � r..nui:�. EQUIPMENT WITHOUT THE 100, bilkj"111111114 • WR TTEN EN SOLAR LCF BLUE 400, 141* ,� NABCEP 11111111141111111°- 1 .II1 1 CERTIFIED PV INSTALLATION PILOT HOLES: FLASHINGS: PROFESSIONAL Drill pilot holes for lag screws or Place flash ings Mad NS + 1" "P�°„9015866 structural screws (as necessary) at — _ CONTRACTOR: BRS HELD OPS marked attachement points sss.ass.s�eo • • • • 7 fiat- ��_� ir NOTE. !f N S Module edge ,s as thine � at the j • r =� / / t shinnts :ourµa above y u have the rp u s tr -'j pivot{rotate shdo at the 2achrne t punt �/ to span the slrxt scaurs and sot zh 1tesas • • • • • f �� r.r eeIJfC@('. ti� r.sr. -� at`Shingte^s aas R uirc�d �` 1i r---V-1 - � 4r MadNS + 2" - V� �it l f 1 ti 1 INSTALL SLIDERS AND TRIMRAIL ROOF ATTACHMENTS: 11.1 a1 1 • I nsert flashi ngs per manufacturer instructions i ;I ... . � - r - I, it diameter of 5/16" I • Attach sliders to rafters u • Verify proper row to row spacing for module size (Mod NS+ 1') II I1-- 0 i I • Ensure that TrimrailTM roof attachments in each row have sufficient II engagement with slider dovetails for proper attachment. 1 , ! DOWN-SLOPE .40. SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0