Loading...
Plans PROJECT DESCRIPTION: -41 .07' SW hAZELCREST WAY ROOF DESCRIPTION ELEMENTAL ROOF TYPE ASPHALT SHINGLE ENERGY ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES -- ---��--�-------- 1339 SE BTH AVE, 25 HANWHA Q.PEAK DUO BLK-G5(320W)MODULES W ROOF ROOF TILT AZIMUTH FO339SE8.OR 9n1a 1 SOLAREDGE SE6000H-US INVERTER Cl,n i, Z #1 20' 180° Phone-(541)316-5786 25 SOLAREDGE POWER OPTIMIZERS(P320) V/ 1 1J Contractor#OR CCB#"195141 , 1 REVISIONS SYSTEM SIZE: 8.00 KWDC d - ILL DESCRIPTION DATE REV 6.00 KWAC o EXISTING DRIVEWAY ,L s 10 NOTE: *CHECK WITH CITY/COUNTY OR LAND I . 0 SURVEYOR FOR ACCURATE PROPERTY LOCATION. ID- 1 NOTE: *PV ARRAY FOLLOWS ROOF TILT. I ` I 1 I (E)200A MAIN SERVICE PANEL WITH 200A ELECTRICAL CONTRACTOR I MAIN BREAKER(INTERIOR) --I 9'-21. �f 1 M= I (E)UTILITY METER(EXTERIOR WALL) 1 ❑ ❑ dM I G5 El ® I (E) GATE I, II (N)60A UTILITY REQUIRED DISCONNECT WITHIN 10' OF UTILITY METER(EXTERIOR) (E)TREES - 1 ❑ 1 (N)SOLAREDGE SE6000H-US INVERTER (EXTERIOR) O PROJECT NAME fI ° U �� I Z w w I 0 < CC o ❑ ❑ o ❑ ❑ Io0: CD w1— � CO �I i CC cn Lij N M w N I I Z K CA C\I\I O (O I Q J r *k Cp ROOF#1 } W 0 N Q t i ° I (25)HANWHA Q.PEAK DUO BLK-G5 N w' (320W)MODULES Z = 0 z 1 1 I o N r I M I < ‘- 0 ROOF#1 I TILT-20° I PROJECT AZIM.-180° I N/A I 1 W I A 9'-10" I.-- SHEET NAME Z J OVERALL SITE PLAN CYI 1 00 4 W I I SHEET SIZE 0_p i 1 ANSI B a OVERALL SITE PLAN -- ---- _i --__' 1PROPERTY LINE SHEET NUMBER �55.01' PV-1 SCALE:3/32"= 1'-0' (E) FENCE MODULE TYPE, DIMENSIONS & WEIGHT { pp EE3 ELEMENTAL NUMBER OF MODULES=25 MODULES SW I I AZ E LC REST WAY ENERGY; MODULE TYPE= HANWHA Q.PEAK DUO BLK-G5(320W)MODULES 1339RTSE ,0 AVE. MODULE WEIGHT=41.2 LBS/18-7 KG. PORTLAND,OR 97214 316-5786 MODULE DIMENSIONS= 66.3"X 39.4"= 18.14 SF (E) FRONT OF RESIDENCE ContrPhactor#o CCB#:195141 UNIT WEIGHT OF ARRAY AVERAGE=2.71 PSF REVISIONS DESCRIPTION DATE REV GENERAL NOTES: — (E)200A MAIN SERVICE PANEL WITH 200A 1. CONDUIT IS DIAGRAMMATIC. FINAL ROUTING TO BE MAIN BREAKER(INTERIOR) DETERMINED BY INSTALLER. I I ROOF DESCRIPTION (E) UTILITY METER(EXTERIOR WALL) ROOF TYPE ASPHALT SHINGLE ❑ -- 1 ❑ ELECTRICAL CONTRACTOR ROOF ROOF TILT AZIMUTH I PRE-ENGINEERED TRUSSES o (N)60A UTILITY REQUIRED DISCONNECT SPACING z WITHIN 10'OF UTILITY METER(EXTERIOR) #1 20° 180° 24"O.C. ❑ T ARRAY AREA & ROOF AREA CALC'S - AREA OF NEW ARRAY AREA OF ROOF(PLAN TOTAL ROOF AREA — (N)SOLAREDGE SE6000H-US INVERTER(EXTERIOR) (Sq.Ft.) VIEW) COVERED BY ARRAY%I (Sq.Ft.) ❑ O 453.51 2500.30 18% 0 18%ROOF AREA(ARRAY<25%OF ROOF AREA) PROJECT NAME BILL OF MATERIALS W U EQUIPMENT QTY DESCRIPTION - Z SOLAR PV MODULE 25 HANWHA Q.PEAK DUO BLK-G5(320W) iv W MODULES INVERTER 1 SOLAREDGE SE6000H-US INVERTER I \ MI ii NI III ;. IM- Cl) OPTIMIZERS 25 SOLAREDGE POWER OPTIMIZERS(P320) \ 1 1 1 1 1 1 • 1 1 1 1 1 1 1 • 1 WN 1— UTILITY DISCONNECT 1 60A UTILITY REQUIRED DISCONNECT 1 .1 I ROOF#1 Lt (I) N ID C\I CO W LARGE POLARIS 2 LARGE POLARIS BLOCK FOR SSC I I t I t I t 4, 1 I 1 I i I I I (25)HANWHA Q.PEAK DUO BLK-G5 Q W Li 4 4 4 I I 1 a 1 I 1- (320W) MODULES z - N a. JUNCTION BOX 1 SOLADECK JUNCTION BOX 1 1 1 1 1 1 1 1 1 1 1 1 1 Q U L. Cr)T I I T T I T I T 1 T T IRONRIDGE XR-100 RAIL J r IRONRIDGE XR-100 RACKING 168"SECTION _ < W 0 N RAIL 20 0, t t f t —t t t t t (E)ASPHALT SHINGLE ROOF,TYP. < N - W' H ICE H Q SPLICE 10 ,SPLICE KIT D • j MID CLAMP 40 'MID CLAMP-UFO I P I +- T 1 T 1 T I 1 T I r I (E)PRE-ENGINEERED TRUSSES @ 24"O.C. Z = -1---1--i 1 -T I t ---T-- r--T- 1 1 Q Q a. ATTACHMENT 86 IRONRIDGE FLASHFOOT2 ATTACHMENT — + —' , t 12"FIRE PATHWAY Cl) >CI) 0 Q D GROUNDING LUG 5 IRONRIDGE GROUNDING LUG -1 L END CLAMP 20 END CLAMP/STOPPER SLEEVE l j l T T1 --1_-- -� 1 \ 1 1 • 1 • i (�) IRORIDGE FLASHFOOT 2 V im I--- —.-- ATTACHMENTS @ 24"&48"O.C. ������� O I I I I I 1 fl CO ROOF#1 I I I 1 1 I Q TII..T-20° 1 1° 1 I 1 I 1 1 1 I 1 U AZIM.-180° c I 1 I I I I I I I I _ `° 1 1 I 1 I I I I I I 1 I 1 LEGEND PROJECT I I I I I I I I I I I 1 UM UTILITY METER N/A \ I I I I I I - -..-- MSP PANEL 1 WITH 0 K 2 A MAIN BREAKER SHEET NAME j' 6'-11" 28'-0" /-- 6'-11" Jr UD UTILITY DISCONNECT ROOF PLAN WITH ' TER MODULES ,JBINV JUNCTIONINVER BOX -- - SHEET SIZE CHIMNEY I ANSI B ROOF PLAN WITH MODULES (E) BACK OF RESIDENCE 0 PIPE VENT 1ATTIC VENT SHEET NUMBER SCALE: 1/8" _ O9\r CONDUIT RUN " V-2 © Copyright Elemental Energy 2020. All rights reserved. (25) HANWHA Q.PEAK DUO BLK-G5 (320W) MODULES - — 66.3" Jr e, ELEMENTAL (1) SOLAREDGE SE6000H-US INVERTER -$ ENERGY (25) SOLAREDGE POWER OPTIMIZERS P320 5�/ II AZE LC REST WAY aas SE arH 197214 6-5 1 PO339 SE 8 OR AVE Phone-(541)316-5786 (1) STRING OF 10 MODULES & M Contracto#OR CCB#r 195141 (1) STRING OF 15 MODULES CONNECTED IN SERIES PER STRING (E) FRONT OF RESIDENCE REVISIONS PHOTOVOLTAIC MODULES DESCRIPTION DATE REV HANWHA Q.PEAK DUO BLK-G5 (320W) MODULES 12 FIRE PATHWAY / C ELECTRICAL CONTRACTOR ❑ 0 0 PROJECT NAME W 0 Z 0 < * -■ - f ■ Q w w 0Js SOLADECK JUNCTION BOX z CV N 0 STRING#1 Q U M ■ — f ---■ — ■ W O N } N I- (25) SOLAREDGE POWER — — —■— — -- • ------■ Z = Lt z J OPTIMIZERS P320 0 I < < 0_■ f --- ■ - Ci) >. 0 a f-- STRING#2 O N ROOF#1 ■ ■ C[ co (25) HANWHA Q.PEAK DUO BLK-G5 Q N— (320W) MODULES 0 0 PROJECT N/A SHEET NAME STRING LAYOUT SHEET SIZE ANSI B STRING LAYOUT SHEET NUMBER ( ) BACK OF RESIDNCPV3 SCALE: 1/8" =I-0" 51\f E*3 ELEMENTAL ENERGY; 1339 SE BTH AVE, EAVE PORTLAND,OR 97214 Phone-(541)316-5786 Contractor#OR CCO#.195141 REVISIONS DESCRIPTION DATE REV I L M m ❑ EAVE 7c m V ELECTRICAL CONTRACTOR Z- ElX �q ,�v PRE-ENGINEERED TRUSSES @ 24"O.C. �� SOLAR MODULE \ .1- m , \ m o X O B ` PV-4 j 20' PROJECT NAME \ LLI RIDGE 0 1 1 1 1 1 • 1 1 1 1 1 1 r `° r t f t I T-----f---t— I' - I t 1 t f w 1— 1 1 1 1 1 4 1 ! 1 ! 1 1 1 I I I I 1 1 I 1 I 1 1 4 Q w (NIN CO IA T T T T1 T 1 T 1 TT N Z N CL T T T i • T 1---t---1- U M 11 1 11 Q - I W ii P T 1-T T — t i I H Ui CL T 1 I T 1 1 T 1 1 1 1 ¢ o _ m i 1 1 1 1 i i 1 • l m / Z 2 Z T T T 1 • I T I TT TT TL Q > Q 0_ I— I I 1 1 1 —1- I1 1 1 l \ \ \ � - Q I I � - I- 1 1 1 1 1 1 1 EXTERIOR LOAD BEARING WALL -� / O N to I fY M I 11 I 1 I I I 1 Q U 1 I 1 1 1 1 1 1 I I I I I I I I I 1 i i I i I I I I I i _ ' PROJECT EAVE ill N/A D> X SHEET NAME m m FRAMING PLAN EAVE SHEET SIZE ANSI B ' � SHEET NUMBER A FRAMING PLAN ; B SECTION DETAIL PV-4 PV-4 SCALE: 1/8" = 1'-0" , SCALE 1/8" = 1'-0" PV-4 Cc)Copyright Elemental Energy 2020. All rights reserved. ! eaELEMENTAL ENERGY 1339 SE8TH AVE, PORTLAND,OR 97214 -- Phone-(541)316-5786 Contractor#OR CCB#: 195141 REVISIONS PV MODULE '\j\ , DESCRIPTION DATE REV '-' O'02,-'s s (E) COMPOSITE SHINGLE ROOF j �A�4- 0. ELECTRICAL CONTRACTOR / N d /" ' PR�� TYPE OF MODULE POINT MOUNTING SYSTEM G �I/ INSTALLATION \, - /i \ INSTALLATION Q.PEAK DUO-GS.X ".sw n ° '' t -`� WITH CLAMPS Q.PEAK DUO BLK-G5.X -- 4- I - aao..w --- ATTACHMENT DETAIL ENLARGE VIEW PV-4.1-2 cn a, at <u PROJECT NAME w HYBRID Q.PEAK DUO-G5.X 0 1 ATTACHMENT DETAIL CLAMPING Q.PEAK DUO BLK-G5.X PV-4.1 SCALE: NTS a Q>> END/MID CLAMP — 4 W N M W INSTALLATION Q.PEAK DUO-G5.X Z U C)ty M a ON MOUNTING Q.PEAK DUO BLK-G5.X PV MODULE POINTS ans�I Q N 0 IRONRIDGE XR100 RAIL 4•f8s1ning — ¢ p LL �, points 345 4 i Fastening _ ALUMN. "L" BRACKET W/3/8" ten` Z 2 cc Z J_ �• SS BOLT & NUT Q Q F— FLASHFOOT2 ATTACHMENT �� Q p / iko % FBI FB2 0 �'.� INSTALLATION Q.PEAK DUO-G5.% CO y I lL (E) COMP. WITH INSERTION O.PEAK DUO BLK-G5.X NOT PERMITTED ,c\ ` SHINGLE ROOF PROFILES I Ct r } 0 5/16"x3.5" SS LAG BOLT WITH ;I i lj MIN 2 1/2" THREAD EMBEDMENT, ' PROJECT �\ SEALED PENETRATION p, IN N/A \\ SHEET NAME ATTACHMENT DETAIL & CLAMPING METHOD SHEET SIZE ANSI B 2 ATTACHMENT DETAIL ENLARGE VIEW 3 CLAMPING METHOD SHEET NUMBER PV-4.1 SCALE: NTS PV-4.1 SCALE: NTS PV-4. 1 DC CONDUCTOR SCHEDULE AND CALCULATIONS ELEMENTAL IT ENERGY TAG LOCATION DESCRIPTION EQUIPMENT #OF STRING OUTPUT CURRENT(A) #PARALLEL #C.CARRYING WIRE WIRE COND. COND. AMBIENT MULTI DERATED 1-WAY VD OCPD NEUTRAL GROUND CONDUIT (CONDUIT WIRE RUN FROM HOME RUN ID STRING ISC(OPTIMIZER) 690.8(A)(1) VOLTAGE M ' RUNS CONDUCTORS SIZE TYPE MATERIAL RATING IA) TEMP #COND. (A) L(FT.) % RATING SIZE SIZE TYPE SIZE 1339 SE BTH AVE, DC1 PV STRING TO JUNCTION BOX STR 2 15 18.75 480 1 2 10 AWG PV WIRE CU 35 0.94 1 32.90 60 0 33% N/A WA 6 AWG FREE AIR N/A I PORTLAND,OR 97214 DC2 JUNCTION BOX TO INVERTER JUNCTION BOX 2 15 18.75 480 I 2 10 AWG THWN-2 CU 35 0.94 1 32.90 75 0.49% N/A WA 10 AWG EMT 3/4" Phone-(541)316.5786 -- -- -- ----- --- CDntrecfoi#OR CCB#:195141 MAX VOLTAGE DROP: 0.82% — - REVISIONS DESCRIPTION DATE REV AC CONDUCTOR SCHEDULE AND CALCULATIONS TAG (A) #PARALLEL #C.CARRYING WIRE ' WIRE 1 COND. I CURRENT COND. AMBIENT MULTI DERATED 1-WAY VD OCPD NEUTRAL GROUND CONDUIT CONDUIT - WIRE RUN LOCATIONFROMCRIPTION IDN HOME RUN ,1 EQUIPMENT # STRING STRINGOF INV.OUTPUT CURRENT 690.8(A)(1) I VOLTAGE(V) RUNS �'CONDUCTORS SIZE TYPE MATERIAL � RATING(A) TEMP #COND. (A) L(FT.) % •RATING SIZE SIZE TYPE SIZE ._ _ AC1 INVERTER TO AC DISCONNECT INVERTER - 25 31.25 240 1 2 8 AWG THWN-2 CU 50 1.00 1 50.00 10 Ii 0.14% 40 8 AWG 10 AWG EMT 3/4" AC2 AC DISCONNECT TO POI_ _ DISCONNECT - 25 31.25 240 I 2 BAW W G THN-2 CU 65 1.00 1 65.00 10 0.09% 40 6AWG 10AWG EMT 3/4" MAX VOLTAGE DROP:, 0.23% ELECTRICAL CONTRACTOR BI-DIRECTIONAL UTILITY METER 10 MODULES W/OPTIMIZERS 1-PHASE, 3-W, 120V/240V CONNECTED IN SERIES PER STRING#1 TO UTILITY GRID PROJECT NAME L1 L2 W 0 #10 #2 #1 Cill Z • . (N)SUPPLY SIDE INTERCONNECTION --_ _0 < -4{ (.1) _ (E)200A/2P MAIN (~/) N in BREAKER(INTERIOR) Q W N SOLAREDGE SE6000H-US(240V) � _ CO 15 MODULES W/OPTIMIZERS OUTPUT:240 VAC,25A • (N)60A UTILITY REQUIRED 200A( ( (E)200A MAIN SERVICE Q 1 f' CONNECTED IN SERIES PER STRING#2 99°k CEC WEIGHTED EFFICIENCY PANEL, 0V W O N NEMA 3R,UL LISTED,INTERNAL GFDI DISCONNECT WITHIN 10'OF CC it (N)SOLADECK UTILITY METER o c I (INTERIOR) < <N - WITH INTEGRATED DC DISCONNECT `-.- JUNCTION BOX (EXTERIOR) k J / -. Q Q #15 • • • #2 #1 E 40A FUSE _� Q DC-- - E O --- - I ;- F- I CD c O --- ,+.- ---. -7 E _,A (l — N CO �4 -0 l I I I j I G © 1� — U GEC DC INPUT POWER-320 WATTS DC1 3/4' EMT AC1 AC2PROJECT DC2 - SOLAREDGE POWER OPTIMIZER P320 RATED _ L GROUNDING N/A — (1)10 AWG THWN-2+RED • ELECTRODE SYSTEM MAXIMUM INPUT VOLTAGE-48 VDC (1)10 AWG PV WIRE+RED (2)8 AWG THWN-2 (2)6 AWG THWN-2 SHEET NAME MPPT RANGE-8 TO 48 VDC (1)10 AWG PV WIRE-BLACK (1)10 AWG NBLACK (1)8 AWGW W THN-2 NEUTRAL (1)6 AWG THN-2 NEUTRAL MAXIMUM INPUT CURRENT-13.75 ADC (1)6 BARE CU GND (1)10 THWN-2 GND-2 - (1)10 AWG THWN-2 GND (1)10 AWG THWN-2 GND IN3/4"EMT CONDUIT IN3/4"EMT CONDUIT ELECTRICAL LINE MAXIMUM OUTPUT CURRENT-15 ADC DIAGRAM STRING LIMITATIONS-8-25 OPTIMIZERS, 5700 WATTS STC PER STRING MAXIMUM SOLAREDGE OPTIMIZERS SHEET SIZE GENERAL NOTES: ANSI B ELECTRICAL LINE DIAGRAM 1. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL LOCAL OR NATIONAL CODE REQUIREMENTS AND SHEET NUMBER EQUIPMENT INSTALLATION INSTRUCTIONS. SCALE: NTS 2. SEE PV-6 FOR LABELING REQUIREMENTS PV-5 ©Copyright Elemental Energy 2020. All rights reserved.