Loading...
Plans Dowers Residence 11.7 kW Photovoltaic System Line Drawing O O VALIDITY OF PERMIT O RECEIVED - - -- -- - THE ISSUANCE OF A PERMIT �—� JUL 2 I 2O20 BASED ON CONSTRUCTION DOCUMENTS AND OTHER Existing Utility i CITY OF TIGARD DIVISION SHALL NOT PREVENT t-jll-DI�,(`,y DIVISION THE CODE OFFICIAL FROM REQUIRING THE CORRECTION 0 - - - - --- - - -- - --- -- — OF ERRORS.ORSC 105A r Ilsco Insulation Piercing Connector 1 String of 12, 1 String of 15, and 1 String - ' `-� - �- -- of 9 Modules with 36 P400 Optimizers DC Voltage Drop: 3 Positive, 3 Negative AC Voltage Drop: A maximum distance of 522 feet will limit the 3 A maximum distance of 129 feet will limit the C - i#10 THHN in 60 of /a voltage drop to 2%or less with a#10 copper voltage drop to 2%or less with a#6 Copper i EMT conductor delivering 15 amps on a 780 volt conductor delivering 42 amps on a 240 volt C C ! system. system. 30.0 Amps Rated ampacity of selected 55 Amps Rated ampacity of selected conductor SOLAREDGE SE10000H- conductor 0.4662 Ohms Resistance(Ohms per 1000 feet) Internal DC 1.14 Ohms Resistance(Ohms per 1000 feet) 0 ' Disconnect US 240VAC INVERTER 0.05 Ohms Reactance(Ohms per 1000 feet) 0.051 Ohms Reactance(Ohms per 1000 feet) 4.8 volts maximum allowable voltage dropat #6 Bare CU Ground 8.84 volts maximum allowable voltage drop at g -- D 2% Power2% i Bonding all rails together 0.9 Factor «rr 0.9 Power Factor r Via and Gnd Lugs/ OFFICE COPY n n 200 Amp Panel Project Name: (Existing) Dowers Residence Approved plans System Specifications; shall be on job site. (36) Panasonic 325 VBHN325KA03 J Modules L1, L2, N #6 THHN 11, L2, N #6 THHN, (1)SolarEdge SE10000H-US Inverter and #10 Ground in 5' 60A Fusible #8 Ground in 10' of of PVC AC Disconnect w/60A 3/4" PVC Modules grounded to racking system CITY OF TIGARD fuses through Ironridge integrated grounding. R':`.'x I `i'tsi) FOR OODE COMPLIANCE LIABILITY Aluminum Rails& Mounting Hardware A, ,4irt.til: I c; C: ( The City of Tigard and its PV Flashing with SS Hardware employees shall not be r? " ' ` + plS 12oZo 0d7-3(° responsible Bible for discrepancies Module Specifications: Inverter Specifications: r ;,, ,it . p p Panasonic 325 VBHN325KA03 SolarEdge : 0H-US i2$7y 9 Morn-r-V}a,(dl which may appear herein. Pmax: 325 Watts Compliance: UL-1741 Vmpp: 59.2 V Max DC Input Voltage: 500V I : Date: 'la,r=O Voc: 70.9 V Max DC Input Cur:30.5A 1 Contractor: Customer: impp: 5.5 A Max AC Output Power: 10,000W _A AligiiiiiiL 11 Three Line Drawing Keith Dowers Isc: 5.94 A Max Output Current: 42A Premier Solar NW 12874 SW Morningstar Dr. Max Series Fuse: 15A Nominal Voltage Range: 240VAC NORTHWEST— PREMIER SOLAR July 14, 2020 12399 NW Waker Dr. Tigard OR. 97223 Max System Voltage: 600V Optimizer Model: Portland, OR 97229 503 704-9112 Dimensions: 62.6"x41.5"x1.57" SolarEdge P400 __.._.rWeight:40.81 lbs. Mounting Notes Roof Mounting_Datail: 1. Eng. Trusses @ 24" O.C. 2. Roof penetrations: 24-48" O.C. So`a dU1e 3. Composition Roofing 4. Panel height off roof< 18 inches 5. Weight of PV modules and assembly ;} less than 4.5 lbs per sq. ft. 6. Azimuth: 1102 & 2002 & 290° • � 7. Module Tilt: 182 Ironridge XR100 Rail 8. Integrated Grounding Hardware 6 inches 9. All installations comply with • position Roofing manufacturer's installation instructions 10. All horizontal ridges kept clear of PV components at least 1 ft. either side Aluminum PV Flashing 11. PV array to cover less than 25% of total _. roof area i \ 12. Solar Code 305.4 #3.2: Attachments Eng. Trusses shall be spaced no greater than 24" 0.C. in at 24" OC any direction when located within 36" of a i roof edge, hip, eave, or ridge. 5/16"X6" SS Hanger Bolt 13. Solar array not to exceed height of any 3" Lag thread for 2.7" Thread horizontal ridge line. penetration in to roofing member Total Roof Area: 4,096 sq. ft. July 14, 2020 Total Solar Area: 693 sq. ft. Solar Covers 17% of Roof Area Keith Dowers EQUIPMENT 12874 SW Morningstar Dr. Tigard OR. 97223 (36) Panasonic 325 503 704-9112 VBHN325KAO3Modules GENERAL CONTRACTOR: (1) SolarEdge SE10000H-US Inverter C&B RENEWABLE ENERGY,LLC 12399 NW WAKER DR. Iron Ridge Mounting System PORTLAND OR.,97229 PREMIER SOLAR 503 828-9500 CONTACT: CLIFF BARRY NORTHWEST Aluminum PV Roof Flashings Dowers Site Plan Roof Structure &Site Map f 114 — ____ I SW Appaloosa PI O 4-10'H 25 N I mu —� v g ---- _,. Ili 119.0 1ill III i r- �� D �i� O 7 v II 4 D I tiz 7-----_____ _.1 III\ 1:3 _ 1\ I, (a CU Y N N 2 Y Y L v c c Irts ni H- Lt ns 24' A__ i ADJACENT PROPERTY A16111146—' Contractor: Customer: GENERAL CONTRACTOR: C&B RENEWABLE ENERGY,LLC Keith Dowers 12399 NW WAKER DR. 12874 SW Morningstar Dr. ` PREMIER SOLAR PORTLAND OR.,97229 Tigard OR. 97223 NORTHWEST- 503 828-9500 503 704-9112 Plot Map July 14, 2020 CONTACT: CLIFF BARRY