Permit CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT •°- COMMUNITY DEVELOPMENT Permit#: FPS2020-00127 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 12/16/2020 Parcel: 1S135AB01002 Jurisdiction: Tigard Site address: 10220 SW GREENBURG RD 101 Project: Spec Space Subdivision: METZGER,TOWN OF Lot: 9 Project Description: Fire Sprinkler permit;add(2)sprinkler and(1)plug for new floor plan.Affidavit submitted. Contractor: BASIC FIRE PROTECTION INC Owner: LINCOLN CENTER LLC 8135 NE MARTIN LUTHER KING BLV BY SHORENSTEIN PROPERTIES LLC PORTLAND, OR 97211 235 MONTGOMERY ST, 16TH FLOOR SAN FRANCISCO, CA 94104 PHONE: 503-285-1855 PHONE: FAX: 503-285-0713 FEES Description Date Amount Specifics: Permit Fee-COM 12/15/2020 $102.20 12%State Surcharge-Building 12/15/2020 $12.26 Type of Use: COM Plan Review-Fire Life Safety-COM 12/15/2020 $40.88 Class of Work: ALT Type of Const: Info Process/Archiving-Sm$0.50(up to 12/15/2020 $0.50 Occupancy Grp: Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Wet Standpipe Required: Hazard: LT Density: 0.1 Design Area: 0 K Factor: 5.6 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $155.84 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $2,423.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. }�,� �(�()�('�'j� Issued By: ks-�� � �� Permittee Signature: UI t 'r'C t ���rl 1 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application -g- 17,1 Cl Fire Protection System RECEIVE , FOR OFFI('E USE ONIA Received '�A 7 Pemdt Na.City of Tigard Date/By: f 09 (/ : 4Z fr l(Z7 , �- •• 13125 SW Hall Blvd.,Tigard,OR 97223 DEC 0 9 ZOO Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date Rev �i Other Permit: T 1 G A R D Inspection Line: 503.639.4175 -, Date Re /B !V • luris ® See Pee 2 for Internet: www.tigard-or.gov CITY OF TIGARD Notified/Method: 19/��/ �G Supplemental Information BUILDING DIVISION ( / E OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Q Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the MEMELCATEGORY OF CONSTRUCTION.. work indicated on this application. ❑ 1-and 2-family dwelling El Commercial/industrial Valuation: $ ❑Accessory building ❑Multi-family Number of bedrooms: El Master builder El Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: - Job site address: 10220 SW Greenburg Rd New dwelling area: square feet City/State/ZIP: Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.:101 Project name: Suite 101 Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Greenburg Rd Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the FINDESCRIPTION OF WORKAIMIIIIM work indicated on this application. Add(1)sprinkler and plug(1)for new floor plan Valuation: $2423.00 Existing building area: square feet New building area: square feet IN PROPERTY OWNER ❑ TENANT 3 Number of stories: Name:Shorenstein Realty Services Type of construction:1-B Address:5335 Meadows Rd. Suite 275 Occupancy groups:B City/State/ZIP:Lake Oswego, OR 97035 Existing:B Phone:( )503-412-4800 Fax:( ) New: It APPLICANT ❑ CONTACT PERSON NOTICE Business name:Basic Fire Protection Inc. All contractors and subcontractors arc required to be Contact name:Uwe Parth licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address:8135 NE MLK Jr Blvd jurisdiction in which work is being performed.If the City/State/ZIP:Portland, OR 97211 applicant is exempt from licensing,the following reasons apply: Phone:( )503-285-1855 Fax: :( ) E-mail:Uwe@basicfire.com CONTRACTOR BUILDING PERMIT FEES* Business name:Basic Fire Protection Inc. (Please refer to fee schedule) Permit fee: Address:8135 NE MLK Jr Blvd State surcharge(12%of permit fee): City/State/ZIP:Portland, OR 97211 FLS plan review(40%of permit fee): Phone:( )503-285-1855 Fax:( ) (Due upon application submittal.) CCB lie.:48641 Total permit fees: Amount received: Authorized signature: Uwe- Pa-t'fiA -- This permit application expires if a permit is not obtained Print name:Uwe Parth Date:12/8/2020 within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. P:\Building\Permits\FPS-PermitApp_031016.doc 440-4613T(11/02/COM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2-Supplemental Information Describe work to be done: 1.) Type of Work: 2.) Addition/alteration only to sprinkler heads: 3.) Addition/alteration only to alarm devices: ❑ New system Number of sprinkler heads: 2 Number of alarm devices: ❑■ Addition or ❑■ 1-10 heads: Affidavit required and ❑ 1-5 devices: Affidavit required and Alteration (3) copies of sketch showing area (3) copies of sketch showing area to existing of work within building structure of work within building structure system ❑ 11+heads: Plan review required and ❑ 6+devices: Plan review required and (3) sets of plans. (3) sets of plans. Additional description of work:Add (1) ssp and plug (1 ) ssp T A.e of S stem Corn.lete A, B, C or D as a. .licable : A.) Commercial Sprinkler Sprinkler Type ❑■ Wet ❑ Dry Additional Standpipes Information: Sprinkler Supply Line ❑■ Yes El No Hazard Group Light Density .10 Design Area K.Factor 5.6 Sprinkler Project Valuation: I $ B.) Type I - Hood Fire Suppression Syste r ` Hood Project Valuation: I $ C.) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component El Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler (Stand Alone Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. P1 Protection Permit Fees Project valuation subtotal (see A,B&C above): $ Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (12%of permit fee): $ FLS Plan Review(40%of permit fee): $ TOTAL: $ �:\Building\Permits\FPs_PemutApp_o31016.doc 2 City of Tigard RECEIVED Permit No.: �pszo�ro� �z� ;�i 13125 SW Hall Blvd.,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1960DEC 0 9 ZOZO Date Received: WQc/2.oJ Inspection Line: 503.639 4175 1 i`' 'I'{:' Internet: www.tigard-or.gov gUCIITY OF TIGARD By: (j/`7 /L qmeo • FIRE SPRINKLER AFFIDAVIT FOR ALTERATIONS OR TENANT IMPROVEMENTS (1 to 10 SPRINKLER HEADS WITHOUT PLANS) Project Name: 3 Lincoln: Suite 101 Occupancy: Office Job Address: 10220 SW Greenburg Rd Tigard OR 97223 Type of Construction: Concrete Suite: 101 Contractor: Basic Fire Protection Inc. phone: 503-285-1855 Number of Proposed or Altered Heads: 2 Type: SSP Hazard: Light Density: •1 0 I Basic Fire Protection Inc. Oregon Construction Contractors Board No. 48641 certify the following is true and reasonably defines the scope of work for this project: a) All work is limited to drops and annoyers in a light-hazard occupancy. b) Positions of sprinkler heads relative to architectural features such as soffits, beams,partitions, walls, etc. complies with current adopted edition of NFPA 13. c) The proposed work does not require hydraulic calculations. d) Only one sprinkler head will be installed from one drop(exception: up to two heads from one drop may be installed when each head is in a separate fire area). e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13. f) Tenant improvements in a new building shall be equipped with Quick Response heads(see 2002 NFPA 13, Section 8.3.3.1 for exceptions). g) The installation shall comply with the requirements of the current adopted edition of NPFA 13. h) Piping shall not be concealed until hangers and bracing are inspected. i) Final approval shall be subject to onsite tests and inspections. In addition, I understand the following is required: • Submit(3)copies of a sketch showing the area of work within the building's structure. • Building fire protection system permit. • A copy of this document with a copy of the sketch attached shall be available for all inspections. Uwe Parth "c.p.,,, ° Signature: °" °`" .aFP, °ma"—®°" `°m`-°s Date: 12/8/2020 °eyem .as u2oso oea. Print Name: Uwe Parth 1:1Building1FormslFireSprinklerAffidavit_071514.docx Page 1 of 1