Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
OFFICE COPY R E I T M E I E R RECEIVED LOCATION: ' r- first-i e.c., 1)64140.-Tv---i-e-cr , "J 19570 SW 90th Court TECH NAME: i r", eZ-e.c,(-A-- TuaLotn,OR 97062 SEP 15 2020 DATE: T SO3.603.0205 F 503 603 0160 JOB#: ,--7.-r•C"If• 0.---) ReitmeierNW.com CITY OF TIGARD PAGE: k OF: .. BUILDING DIVISION DIVISION 4re ... 42 ' - kA) (111-U--- ‘P•- t,,,/ 1 , -; e . • OFFICE COPY• 4 CITY OF TTGARD,, -t REVIEWED FOR CODE COMPLIANCE :i Approvedi'-{,1 ] -,..7 t 2 OTC: 1 I 1 N : - i Permit #: "41:rwsanctla-90G---62-- -- 3 Address: ) j aS )4 c j) a jvci 1 \ A\ Suite #: By ----i-4) ' Date: jo-at-aD 1 1 i . 1 *L3) ‘[...-.4.....„.„ t-thoc, [ 'Th 1 A-Liar4i- 4 ( v,..)-:94?_..t. ) O- 2-. ft 4 • ii A IF'' E •e-4W A-I L •-rtilitiet .tia.., crizz.3 Le-PLA-t&.‘A.4.0--gr I — _ jREITMEIER LOCATION. 6r... .' 8c 15(<�_ r 19570 SW 90th Court TECH NAME: Gt-ct i -•. Tualatin,OR 97062 DATE; 41' 1 o 1-43 T 503.603,0205 F 503.603.0150 JOB#: _ ReitmeierNW.com PAGE: OF: 2- 6 u M I rs/)6 i 14 gmbL by - � 17-R4 ?.-!$"--1 I ,y, t......,,,,,,,,Z7 re to vt�� jo G3"' ,fir a "yal, C.4-1) wir-7, ,:j - - - F ir. <16'1. wt apt-iv),,hitt, , P4 -: ' cue, 1 era_ '‘.).brkOr , C.,,„.4,,, ,0gyp.. etoC.v4,,actowrenQtr I ae,,,,,,,c,,, e.. ..elLt-irekos...P.r" -I - : 1 N-" ICA4 14N 1 • P-SERIES SUBMITTAL DATA: PKA-Al2HA7 & PUY-Al2NKA7(-BS)12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM MITSUBISHI %_ELECTRIC Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PKA-Al2HA7 ❑ PUY-Al2NKA7 o PUY-Al2NKA7-BS 011i411111111111111111111111 IiCl::::::1'':IIIIIIIIIII11111i!!IIII h1 III IIIIIhiIIIIIIIIVIIIIIIIIIIII110111: '!111111IIIII11IIIIIIIIIIIIIIIIIIIr 1i411110011IIIDlIjD INDOOR UNIT FEATURES• Sleek,compact design �r��+ r,v�D • Simple installation G 1� • Vane setting for air flow direction control �02D • Auto fan speed mode SEp 15 • Ideal for spaces such as server rooms,daycare centers,classrooms,churches,small offices,and more TIGARD GVTY OF p►vlsloN BUILDING OUTDOOR UNIT FEATURES • Variable speed INVERTER-driven compressor • Power receiver pre-charged with refrigerant volume for piping length up to 100 ft(70 ft.for Al2/18/24/30) • Low ambient cooling down to-40°F providing 100%capacity(only for PUY models with wind baffles installed) • 24-hour continuous operation(cooling mode) • High pressure protection • Fast restarts in cooling mode(15 seconds for 12/18/36/42;50 seconds for 24/30) • Superior energy and operational efficiency Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: PKA-Al2HA7 & PUY-Al2NKA7(-BS) Indoor Unit PKA-Al2HA7 Model Number PUY-Al2NKA7 Outdoor Unit PUY-Al2NKA7-BS Maximum Capacity Btu/h 12,000 Rated Capacity Btu/h 12,000 Minimum Capacity Btu/h 5,800 Maximum Power Input W 1,000 Cooling1 Rated Power Input W 1,000 Moisture Removal Pints/h 2.0 Sensible Heat Factor 0.81 Power Factor % 94.5 SEER 20.8 Efficiency EER1 12.0 Voltage,Phase,Frequency 208/230V,1-phase,60 Hz Guaranteed Voltage Range VAC 198—253 Voltage: Indoor-Outdoor,S1-S2 V AC 208/230 Electrical Voltage:Indoor-Outdoor,S2-S3 V DC 24 Voltage:Indoor-Remote controller V DC 12 Recommended Fuse/Breaker Size A 15 Recommended Wire Size(Indoor-Outdoor) AWG 14 MCA A 1 Fan Motor Full Load Amperage A 0.33 Fan Motor Output W 30 Airflow Rate,Dry CFM 320-370-425 Airflow Rate,Wet CFM 290-335-380 External Static Pressure in.WG n/a Sound Pressure Level dB(A) 36-40-43 Drain Pipe Size In.(mm) 5/8(16) Condensate Lift Mechanism,Max.Distance In.(mm) n/a Indoor Unit Heat Exchanger Type Plate fin coil External Finish Color White Munsell 1.OY 9.2/0.2 W:In.(mm) 35-3/8(898) Unit Dimensions D: In.(mm) 9-13/16(249) H: In.(mm) 11-5/8(295) W:In. 39-6/16 Package Dimensions D:In. 15-12/16 H:In. 13-6/16 Unit Weight Lbs.(kg) 29(13) Package Weight Lbs. 33 Indoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum) °F 90 DB,73 WB/66 DB,59 WB Temperature range 1 Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: PKA-Al2HA7 & PUY-Al2NKA7(-BS) Indoor Unit PKA-Al2HA7 Model Number PUY-Al2NKA7 Outdoor Unit PUY-Al2NKA7-BS MCA A 11 MOCP A 28 Fan Motor Full Load Amperage A 0.50 Fan Motor Output W 46 Airflow Rate CFM 1,590 Refrigerant Control Electronic Expansion Valve Heat Exchanger Type Cross fin Sound Pressure Level,Cooling1 dB(A) 44 Compressor Type INVERTER-driven twin rotary Compressor Model SNB092FNCM Compressor Rated Load Amps A 7 Outdoor Unit Compressor Locked Rotor Amps A 12 Compressor Oil Type//Charge oz. FV50S//12 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater n/a W:In.(mm) 31-13/16+7/16(809+62) Unit Dimensions D:In.(mm) 11-3/16(300) H:In.(mm) 24-13/16(630) W:In. 37-1/16 Package Dimensions D:In. 16-3/16 H:In. 27-7/16 Unit Weight Lbs.(kg) 92(41) Package Weight Lbs.(kg) 104(47) Outdoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum) °F 115 DB/-40*DB Temperature Range Type R410A Refrigerant Charge Lbs,oz 4 Ibs,7 oz Gas Pipe Size O.D.(Flared) In.(mm) 1/2(12.7) Liquid Pipe Size O.D.(Flared) In.(mm) 1/4(6.35) Piping Maximum Piping Length Ft.(m) 165(50) Maximum Height Difference Ft.(m) 100(30) Maximum Number of Bends 15 Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: PKA-Al2HA7 & PUY-Al2NKA7(-BS) Notes AHRI Rated Conditions(Rated data is tCooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB determined at a fixed compressor i speed) Wind baffles required to operate below 23F DB in coolingmode.For PUY models,wind baffles q p can be utilized to extend the cooling operation range to -40F.Please refer to the wind baffle submittals to determine which baffles are required to meet the desired operation range. ""System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION • External Outer Panel:Phosphate coating+Acrylic-Enamel coating • Fan Motor Support:Epoxy resin coating(at edge face) • Separator Assembly;Valve Bed:Epoxy resin coating(at edge face) • "Blue Fin"treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: PKA-Al2HA7 Signal Receiver o PAR-SA9CA-E Wireless Remote Controller o PAR-FL32MA-E Wireless Remote Receiver o PAR-FA32MA-E Backlit,Wall-mounted,Wireless Controller ❑MHK1 Portable Central Controller ❑MCCH1 Wired MA Controller ❑PAR-33MAA Simple MA Controller ❑PAC-YT53CRAU Touch MA Controller o PAR-CT01 MAU-SB Wired Remote Sensor ❑PAC-SE41TS-E Lockdown Bracket for Wireless,Hand-held,Remote Controller o RCMKP1CB Wireless Temperature and Humidity Sensor ❑PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 o MOS1 Flush Mount Remote Temperature Sensor o PAC-USSEN001-FM-1 Wireless Interface n PAC-USWHS002-WF-1 Thermostat Interface o PAC-US444CN-1 kumo station® n PAC-WHSO1HC-E USNAP Interface PAC-WHS01UP-E IT Extender o PAC-WHS011E-E BACnet®and MODBUS®Interface ❑PAC-UKPRC001-CN-1 Connector for CN32(remote on/off) o PACSE55RA-E External Drain Pump o PAC-KEO7DM-E External Drain Pump ❑PAC-SH75DM-E Blue Diamond Sensor Extension Cable-15 Ft. ❑C13-103 Mini Condensate Pump-230V application ❑S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor ❑X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)up to 48,000 Btu/h o X87-721-208/230V [recommended) MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 Btu/h o X85-003 Fascia Kit for MicroBlue Pump—mounts the MicroBlue and sensor directly beneath the indoor unit o T18-016 Drain Pan Level Sensor(Control for indoor unit shut off to prevent drain pan overflow) ❑DPLS2 3 Pole Disconnect Switch(30A/600VUL)[fits 2"X4"utility]-Black ❑TAZ-MS303 3 Pole Disconnect Switch(30A/600VUL)[fits 2"X4"utility]-White o TAZ-MS303W Specifications are subject to change without notice. 0 2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. • ACCESSORIES: PUY-Al2NKA7(-BS) Air Outlet Guide o PAC-SJ07SG-E Front Wind Baffle o WB-PA4 Side Advanced Wind Baffle ❑WB-SD4 Rear Advanced Wind Baffle o WB-RE4 Drain Socket o PAC-SJO8DS-E Centralized Drain Pan ❑PAC-SG63DP-E M-NET Converter o PAC-SJ19MA-E M-NET Converter ❑PAC-SJ96MA-E Control/Service Tool ❑PAC-SK52ST Hail Guard o HG-A5 Condensing Unit Mounting Pad 16"x 36"x 3" o ULTRILITE1 Outdoor Unit Stand-12"High o QSMS1201M Outdoor Unit Stand-18"High o QSMS1801 M Outdoor Unit Stand-24"High o QSMS24O1 M Heavy Duty Wall Mounting Bracket for Outdoor Units—Coated Steel o QSWB2000M-1 Heavy Duty Wall Mounting Bracket for Outdoor Units-316 Series Stainless Steel o QSWBSS 1/4"x 1/2"x 15'/1/2"Lineset(Twin-Tube Insulation) o MLS141212T-15 1/4"x 1/2"x 30'/1/2"Lineset(Twin-Tube Insulation) ❑MLS141212T-30 1/4"x 1/2"x 50'/1/2"Lineset(Twin-Tube Insulation) ❑MLS141212T-50 1/4"x 1/2"x 65'/1/2"Lineset(Twin-Tube Insulation) ❑MLS141212T-65 1/4"x 1/2"x 100'/1/2"Lineset(Twin-Tube Insulation) o MLS141212T-100 Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: PKA-Al2HA7 & PUY-Al2NKA7 (-BS) PKA-Al2HA7 Unit:inch(mm) I.,,I.,e, ,ep so. MM. c Ili i. Mil lrl=Mr -1..iiMiln1iiiniiiMl M. -_-------_— MZMepxe 2J.v1E1536i I fmnlsbe 99MYe• „Di' � � r . �., ,, I� -II _, .,,,. A hi 1 e�wmmie. Ido 551 n-v1q 61 uvlplss) Til K,ea-mmM v1p6) IS hw4P^6 l.OMIS p F..M.mm�orm, a..pnn 1nn^.a-+!n llrvgl m, per`_ O0 avz-erM M-uz•e 1d I_FI .— H 'iiiiiillii 411 ....„m,,,.--- : + � I a NM6mne., , °Ipn6 ep m { -,"0 1 - ,Fw ..,.um, Demos*rs*MMDBIU. _ 24-11161612) M 5 iiii, 1 'i NFX9K+tl�WW MO° iHF(d6.95) i� MI F"3 Gm PM 112F03121) •7i1.011.rl Iwn... 08 oom Dram M1eee veIer016)D.D Ain 1544 OK Gnl.,meryvpm•N hale 094 2.51 6g5116(PB) PoY Mk (+ 44���� Kp� 5 G ..:N F6 §`y¢g,a p ram- p� P.N.-A Indoor IrS n.w16G911 rg-�b'- g - ' - - - I '£tl .. ea gJ e CI afl I _1YI521.8) s'p,21 M�.� 'cz=� __ _ = s_'7-.T.E.l Mom° ��1v u, 1y1y1 yy5) ■�IEdS_s _�3e,7.dl t111gipJ�i � 1 midi; 61G `di; _ _ MI6; ,warST��JJII22gqJB51 y r mfilimp 41MHa151 �a i 16JNIZI°}I ! c g'!� 1838,"818.aml e'-y > _ 1"R',.... Kno.`F oul Mk for plpinp —t1� Rqureecpacellmaol und) Ire # i=ri-.024 ' 'PM,/1NN 5 5r .' Ia &g TE i1pi15% v I1111 s a K �� � �� lug Y 1-tlll pall I 'YMK) B 2S1p9°) • Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: PM-Al2HA7 & PUY-Al2NKA7 (-BS) PUY-Al2NKA7(-BS) Unit: mm<in> 404.5<15-15116> drain hole en Nr intake -4 2-U Sh.'•.notched hd- eft `1' "installation,oil pitch (Foundation Bolt M100W 3/8>) 7 500<19-1/16> < -!mow--- INI Air in ( --� ' - Air discharge.. ... ... i 1 ry 40<1-19/32>�I m li 2-10)21 oval hole Lo 23.2<15/16> 22.3<29/32> oundaticn:ot` ,M Service panel <W3/8s <7f8> Terminal connection for charge plug II Left.-Power supppiy wirin;3 /1}�� \Right Indoor/outdoor wiring r �p Hartle for movmV/ _ - r Conlr' q ion for d pipe FLARE e8.351114F) m a Earth terminal y� m Sery a Donal _i--— v — - ^m m to, o ? N V V /j ��yq R m • A ffi 2-a22.247/6> N - - 1/2 conduit hole += - - Connection for ' A gas pipe FLARE e12.7(112F) 154.5<6-3/32> J Service port 185.5 A-5l16> 310<12-7/32> vt v g m - m 809<31-7/8> 62<2-15/32> Free space around the outdoor unit FOUNDATION BOLTS (basic example) Please secure the unit firmly with 4 foundation(M10<yy3/8>)bolts. 4/ , (Bolts,washers and nut must 8 100mm<3-15/16>or more as long as be purchased locally). no obstacle is placed on the rear and right-and-left sides `m J of the unit <Foundation bolt height> lill1)1111: 11�11111111IIIIIIi!!11111 IIIIIIIIiI!!Ip4! 'I MIL_I Minl0Omm l' IIIIIIIIIIViiI Mln'"M i <y;y,a> ILIA'IIIIIC!IIIIIII'�ialllliiii, C<13-za32>> ry FOUNDATION/ II IIIIIIII�I111'IIII11111IIIII!I E 111ii'C!:111IIIIIIIII1111!It((!illl 4 • Min.500mm Mln.100mm PIPING-WIRING DIRECTION C<1s-1vls>/ c51518> ✓✓✓✓ Piping and wiring connection can be made from the rear direction only. 2 sides should be open in the right,left and rear side. Ai. MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com AIM CERTIFIED_ 4:21 FORM#PKA-Al2HA7/PUY-Al2NKA7(-BS)-201810 ------ Intern. - Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.