Report
C 21)2O-6t t Air Handling Unit (MAU-1) Page 1 of 20 RECEIVED S E P 3 0 2020 CITY OF TIGARD BUILDING DIVISION JOHNSON AIR PRODUCTS SUBMITTAL Make-up Air Unit by Greenheck Project: Durham AWWTF Bisulfite Storage Room MAU Replacement Project Address: 16060 SW 85th Ave Tigard, OR 97224 Architect: Engineer: Harris Group, Inc. General Contractor: Mechanical Contractor: Hydro-Temp Mechanical Date: 10/1/2020 Air Handling Unit (MAU-1) Page 3 of 20 Project: Durham AWWTF Bisulfite Storage Room MAU Project ID: P20-0728 JOHNSON AIR PRODUCCTSS Spec Section: Air Handling Unit (MAU-1 ) Submittal Name Make-up Air Unit by Greenheck Vendor/Subcontractor Johnson Air Products Danny Ruby £ GREENHECK Air Handling Unit (MAU-1) Printed DafbV0 Job: Durham AWWTF Bisulfite Storage Room Building Value in Air. Mark: 81 OMAU5001 Model: DGX-P120-H22 DGX-P120-H22 Unit Performance Design Conditions Elevation (ft) DB (°jumm W6(°F) Winter(°F) Supply(CFM) Outdoor Air(CFM) 108 91.2 69.4 23.9 7,000 7,000 Unit Specifications Qty Weight(lb) Cooling Type Heating Type Unit Installation Unit ETL Listing 1 1,187(+/-5%) None Direct Gas-Fired Outdoor/Indoor ANSI Z83.4/CSA 3.7 Configuration Unit Orientation Unit Configuration Outdoor Air Intake Return Air Intake Supply Air Discharge Horizontal Constant Volume 100% End - Bottom Heating Specifications Gas Pressure Capacity(MBH) Performance Type Gas Type Min Max — Temperature(in.wg) (Psi) Input Output Rise(°F) EAT(°F) LAT(°F) Direct Gas Natural 9 0.5 255.6 235.1 31.1 24.0 55.0 Total External SP Total SP Operating Fan Type Volume (in.wg) (in.wg) RPM (CFM) Power(hp) Qty Type Size(in.) Drive-Type Supply 7,000 2.5 3.4 2209 6.73 1 ' Plenum 19.7 -Direct-Drive Motor Specifications Motor Qty Size (HP) Enclosure Efficiency RPM Supply Fan Motor 1 7-1/2 TEFC NEMA Premium 1770 Electrical Specifications Power Supply Rating(V/C!)) MCA(A) MOP(A) i Unit 460/60/3 14.1 25 `NTERTE,. JO-i c s LISTE Generated by:druby@johnsonair.com CAPS 4.33.1049 G:\DannyRuby\Secured Jobs 2020\A-F\Durham AWWTF Bisulfite Storage Room.gfcj Page 1 of 13 ®GREENHECK Air Handling Unit (MAU-1) Printed Da ea.q(?A id 0 Job: Durham AWWTF Bisulfite Storage Room Building Value in Air. Mark: 810MAU5001 Model: DGX-P120-H22 CONSTRUCTION FEATURES AND ACCESSORIES Unit Accessories Unit Installation- Indoor or Outdoor Std Factory Installed, Lockable, NEMA 3R Disconnect Std Unit Construction-Double Wall X Weatherhood -Birdscreen X Wall Insulation- 1 in.fiberglass-Entire unit X Supply Air Filters-2" MERV 8,20x20x2-(6) X Base Insulation- 1 in.fiberglass-entire unit base pan Std Outdoor Air Inlet Damper Paneled Bottom- Sheet metal liner for base insulation Supply Air Outlet Damper Corrosion Resistant Fasteners Std Return Air Damper Access and Connections- Right side when facing intake X Diffuser Service Access- Hinged access doors X Roof Curb Unit Finish-Permatector ASTM B117 salt spray 2500 hours X Combination Curb Finish Color-Concrete Gray(RAL 7023) X Electrofin Coil Coating Supply Fan -Direct-drive, backward-curved plenum X Fan Bearing Extended Lube Lines Supply Fan and Motor Vibration isolation-Neoprene X Inlet Damper Module Controls Spare Belts Unit Controls-Terminal strip with remote panel X Spare Filters Remote Panel-Severe Duty(NEMA 4X and 12) X Motor with Shaft Grounding BMS Communication Service Outlet BMS Protocol Service Lights Temperature Control -Room control X Gas Heating Accessories Supply Fan VFD-VFD by factory X Pilot Ignition Std Supply Fan Control -Constant Volume X Flame Sensing-Flame rod X Unoccupied Mode(Night Setback) Flame Safeguard Display Control Accessories Agency Approval-ETL Std Remote display FM Compliant X Heating Inlet Air Sensor X High Gas Pressure Switch X Cooling Inlet Air Sensor Low Gas Pressure Switch X Dirty Filter Switch Visual Indication Valves Fire Stat Type III (Ships loose) Proof of Closure Valve 120V/24V Smoke Detector(Ships loose) External Gas Pressure Regulator(Ships loose) Inlet Damper End Switch Carbon Dioxide Sensor(Ships loose) External Cooling Lockout Relay Warranty Options Freeze Protection (Supply Air Low Limit) Unit Warranty- 1 Year X Auxiliary Supply Starter Contacts 5 Year Compressor Warranty Auxiliary Exhaust Starter Contacts 5 Year Burner Warranty Airflow Proving Monitoring Contact X 10 Year Burner Warranty Standard Option Std Not Included Included X Notes Birdscreen weatherhoods ship knocked down and require field installation. Generated by:druby@johnsonair.com CAPS 4.33.1049 G:\DannyRuby\Secured Jobs 2020\A-FDurham AWWTF Bisulfite Storage Room.gfcj Page 2 of 13 • �GREENHECK Air Handling Unit (MAU-1) Printed Daeea.R,AV2 O Job: Durham AWWTF Bisulfite Storage Room Building Value in Air. Mark: 810MAU5001 Model: DGX-P12O-H22 Fan Charts And Performance Total Volume External SP Total SP Operating Motor Fan (CFM) (in.wg) (in. wg) RPM Power(hp) Qty BHP) Qty Type Drive-Type 7,000 2.5 3.4 2209 ' 6.73 1 . 7-1/2 1 Plenum Direct Pressure Drop(in.wg) Weatherhood Filter Damper Cooling Heating External Total 0.033 0.242 - - 0.625 2.5 3.4 Sound Performance in Accordance with AMCA Sound Power by Octave Band Lwa dBA Sones 62.5 I 125 250 500 1000 2000 4000 8000 56 68 84 89 94 I 90 85 78 97 86 55 Supply Fan 8 8 2209 FRPfy 7 A,, 7 6 6 3 5 5 a L D d 4 $ 4 m a w b a E3 i ..c 3 w o. '3 m \ rn 0 2 \ 2 �� 1 c° Sys`eR \ 1 0 -.-- \ 0 0 1 2 3 4 5 6 7 8 9 10 Volume(CFM)x 1,000 G Operating Bhp point v Operating point at Total External TP Fan curve System curve Brake horsepower curve Generated by:druby@johnsonair.com CAPS 4.33.1049 G:\DannyRuby\Secured Jobs 2020\A-F\Durham AWWTF Bisulfite Storage Room.glcj Page 3 of 13 • fJ1GREENHECK Air Handling Unit (MAU-1) Printed Daeea.9fak 12 0 Job: Durham AWWTF Bisulfite Storage Room Building Value in Air. Mark: 810MAU5001 Model: DGX-P120-H22 Heating Specifications Gas Pressure Capacity(MBH) Performance Type Gas Type Min Max Temperature(in.wg) (Psi) Input Output Rise( F) EAT(°F) LAT(oF) Direct Gas Natural 9 0.5 255.6 235.1 31.1 24.0 55.0 Gas Train Details Redundant Electronic Internal Visual Proof of Gas Pressure External Main Modulating Pilot Valve Regulator Indication Closure Valve Switch(es) Regulator Valves Valve Valve Std Std Std Std - - High & Low - Additional Heating Information • ETL Approved FM Compliant Temperature Flame Sensing Ignition Control CO2 Sensor Flame Safeguard Control Display Std Yes Room Flame Rod Pilot - - Unit Details 92%thermal efficiency 10 second pre-purge sequence Cast aluminum burner manifold with stainless steel mixing plates Low fire start Electronic modulation burner control Gas Connections - 2.000 L - r It 15.000 �- ELECTRICAL 1 CONNECTION 3/4" NPT GAS CONNECTION • H 10.250 2.250 Generated by:druby@johnsonair.com CAPS 4.33.1049 G:\DannyRuby\Secured Jobs 2020\A-F\Durham AWWTF Bisulfite Storage Room.gfcj Page 4 of 13 ®GREENHECK Air Handling Unit (MAU-1) Printed Datel$ i, ?l2I0 Job: Durham AWWTF Bisulfite Storage Room Building Value in Air. Mark: 810MAU5001 Model: DGX-P120-H22 ELEVATION VIEW 45.564 -24.086-i- - 52.308 - 32.238 - 7/ � 44.924 _ i - � I Notes-Elevation View Standard configuration for unit access is on the right-hand side,when looking into the unit intake in the direction of airflow. Order of unit sections is from intake of unit to discharge of unit. Sections included on this unit:Weatherhood Section, Filter Section, Heating Section, Blower Section Insulation: Double Wall, Entire Unit Insulated. PLAN VIEW PLENUM BLOWER 32.238 • - ACCESS SIDE 3.75 • —"— INTAKE V-BANK FILTER BURNER r 45.564 H 24.086 52.308 - - 25.5-- _ 9.264 SUPPLY DUCT 25.5 43.771 _ ( ACCESS SIDE ACCESS SIDE ACCESS SIDE CONTROL CENTER Notes -Plan View Standard configuration for unit access is on the right-hand side,when looking into the unit intake in the direction of airflow. Generated by:druby@johnsonair.com CAPS 4.33.1049 G:\DannyRuby\Secured Jobs 2020\A-F\Durham AWWTF Bisulfite Storage Room.gfcj Page 5 of 13 [/GREENHECK Air Handling Unit (MAU-1) Printed DatPea.9TA t2 0 Job: Durham AWWTF Bisulfite Storage Room Building Value in Air. Mark: 810 MAU 5001 Model: DGX-P120-H22 END VIEW - 44.125 • �, \\ 44.924 FOOTPRINT VIEW 81.750 CURB LENGTH RECOMMENDED —25.500 _ , 1 7.63 Supply 40.500 Duct 25.500 CURB WIDTH RECOMMENDED 7.37 1 2.25 Notes -Footprint View Minimum Roof Opening: The minimum roof opening size is the illustrated duct diameter plus 0.25 in.on all sides. For example: If the duct size is 14 x 14 in. square,the minimum roof opening size is 14.5 x 14.5 in.square. Maximum Roof Opening: There must be a minimum perimeter of 1.75 in. between the roof opening and the roof curb. For example: If the roof curb is 75 x 30 in.square,the maximum roof opening is 71.5 x 26.5 in. inches square. The weatherhood and filter sections of the make-up air unit extend beyond the curb. This is by design,to prevent water infiltration. Generated by:druby@johnsonair.com CAPS 4.33.1049 G:\DannyRuby\Secured Jobs 2020\A-F\Durham AWWTF Bisultite Storage Room.glcj Page 6 of 13 GREENHECK� Air Handling Unit (MAU-1) Printed Dgf 9 dfbq� 0 Job: Durham AWWTF Bisulfite Storage Room Building Value in Air. Mark: 810MAU5001 Model: DGX-P120-H22 Clearance Specifications Recommended Minimum Combustible Clearances Floor(in.) Top (in.) Sides (in.) Ends (in.) Insulated Units 0 0 0 0 Non-Insulated Units 0 6 6 6 Notes -Combustible Clearances Clearance to combustibles is defined as the minimum distance required between the heating source and the adjacent combustible surfaces to ensure the adjacent surface's temperature does not exceed 90 F above the ambient temperature. Recommended Minimum Service Clearances Housing 32 and less(in.) Housing 35 and higher(in.) 42 on the controls side of the unit 48 on the controls side of the unit Notes-Service Clearances To ensure ample space for component removal (evaporative cooling media, coils,filters, etc.), service clearances should be 6 in.wider than the width of the module itself. Generated by:druby@johnsonair.com CAPS 4.33.1049 G:1DannyRuby\Secured Jobs 2020\A-F\Durham AWWTF Bisulfite Storage Room.gfcj Page 7 of 13 Air Handling Unit (MAU-1) Printed DgfV.96/b?f2 0 �GREENHECK Job: Durham AWWTF Bisulfite Storage Room Building Value in Air. Mark: 810MAU5001 Model: DGX-P120-H22 Wiring Diagram ^^ __ro� � �® ®GREENHECK Ta OV R--b� � n Building Value in Air. G IC ''''" 11 IC w.1,9 NW.'"Cm. I GD63C692B000N1OAM21 CAUTION S NIT T O1BE GROUNDED IN ACCORDANCE WITH NEC. P OWER MUST BE OFF WHILE SERVICING. NOTES ▪F COFFER CONDUCTORS OILY C FOR TERUINSIC RATED LESS TVM I W ASPS UINALC Hw'ED I W MPSOA PAU iE 91 I REIDCON TEDTw W RING RESISTANCE SHOULD wwEDD D FACTOR PPLEDA WIRED WIRE COLOR CODE NN m ex ST BMN Li EL LIO BORANGE RO.PN PINK pR PURPLE wE R RED w vwlE V LEGEND ® my• P AMP AMPLIF.ER OSI M4YDWCONNEGT%MOH FSC FIRE SYSTEM CONTACT ENG FLUE SAFE GUARD USE HLC HIGH LIMIT COXTROL ID MOTOR MOWUTING VALVE C q.Y MOTp+OVEIiMD SWAN REIAY NR FROYINGSWRCH -IF El •.. ME MC A]� TUSSLE F AI P&LOW GAB PRESSURE SWITCH P.MISR GM PRESSURE SWITCH SUPPLYEtf FOR RELAY RFI FAN ERASER RELAY SI EOAGUSF FANSWITCR SU F.SMFCN SI XEPT ARO COOL SWITCH SG SPARS DENEPATCR STX STARTER 1RP MOTOR RMLPORMER lu DISCHARGE AR SENSOR • MISER/CURE SELECTOR T.INLET AR SENSOR.NEAT VI PLOT VALVE VALVE FWC)ARIABLE FREDUENCY PAVE R -41-- Fly a R av - RGOAI POST MEAT EITIrs'.© IEcI © co©. TNo«< <® ®• mRECT GAS wNmw usER iNIERFAGEmREc s, FROVINe MIT. Mil M CONTROL PR COACTS MNINIE cw SLa DRY wl cwNTIOS TRCL SIGNAL WFMG BY mHERS inkil IORC®T ROTI SIAA. N IN9 A e❑-77. • • I � J99y�AI EI�6 i® ❑wu ,V,S MINS*.:WI DOC XUAEEN.— eve— Manufacturer reserves the right to change, modify, or improve this product at anytime Generated by:druby@johnsonair.com CAPS 4.33.1049 G:1DannyRuby\Secured Jobs 2020\A-F\Durham AWWTF Bisulfite Storage Room.gfcj Page 8 of 13 Air Handling Unit (MAU-1) Printed DgMelaQf2CL0 JGREENHECK Job: Durham AWWTF Bisulfite Storage Room Building Value in Air. Mark: 81 OMAU5001 Model: DGX-P1 20-H22 Severe Duty - Remote Control Panel GREENHECK TSCPa�w a a, REMOTE CONTROL PANEL G46A21X3XF2AXXT03 6L0wER rib 12.00" 400 affmaraz 8.00" 6.00' Standard Construction Features And Notes Location of switches, lights and controls may vary. All dimensions shown are in units of inches. The severe duty panel will meet the requirements of NEMA 4X and 12.The switches and lights are mounted on the outside of the panel.All other controls will be mounted inside the panel. Generated by:druby@johnsonair.com CAPS 4.33.1049 G:\DannyRuby\Secured Jobs 2020\A-F\Durham AWWTF Bisulfite Storage Room.gfcj Page 10 of 13 Air Handling Unit (MAU-1) Printed DaPi 9afb?12 0 • /BGREENHECK Job: Durham AWWTF Bisulfite Storage Room Building Value in Air. Mark: 810MAU5001 Model: DGX-P120-H22 Remote Panel Wiring Requirements LIGREENHECK Building Value in ANT. Wlny Dlegem Cede: G4BA2IX3XF2AXXT03 CAUTION UNIT SHALL BE GROUNDED IN ACCORDANCE WITH N.E C. POWER MOT BE OFF WHILE SERVICING 13 . NOTES USE COPPER CONDUCTORS ONLY 60'C FOR TERMINALS RATED LESS THAN 100 AMPS. IC C FOR TERMINALS RATED 100 AMPS OR MORE. FIELD CONTROL WIRING RESISTANCE SHOULD NOT EXCEED 035 OHM. FIELD WIRED 5T YELLOW ❑ FACTORY SUPPLIED AND WIRED SUPPLY SWITCH WIRE COLOR CODE BK BLACK BL BLUE BR BROWN GY GRAY LT EL LIGHT BLUE 0 ORANGE PK PINK PR PURPLE R RED W WHITE V YELLOW RACK W 1 HEAT SWITCH © BLACK O WHITE PLOHER LI0R 39 0 38 HEAT LIGHT mYELLOW Q WRITE FLAME FAILURE ALARM LIGHT ® BILE ® BIER El TEMP.SELECTOR MAYBIRa TDIr NOTES: REFEMOSTAT.. 7MT el. ED cwM TrmLAal.D,MDRO T09 DOC NUMBER.— REv:— The wiring drawings details the number of the wires and the type of wire that needs to be run from the unit control center to the panel. A detailed wiring schematic will be provided with the panel when the unit ships. Generated by:druby@johnsonair.com CAPS 4.33.1049 G:\DannyRuby\Secured Jobs 2020\A-F\Durham AWWTF Bisulfite Storage Room.gfcj Page 11 of 13 Air Handling Unit (MAU-1) Printed DAPeiagif0 ° �GREENHECK Job: Durham AWWTF Bisulfite Storage Room Building Value in Air. Mark: 810MAU5001 Model: DGX-P120-H22 SEQUENCE OF OPERATIONS • Unit Controls The unit shall be provided from the factory with: • 24VAC Transformer • Terminal Strip • Supply fan VFD • Remote Control Panel Remote Control Panel A stainless steel NEMA-4X and NEMA-12 rated remote control panel shall be shipped loose to control the basic operation of the unit. The panel shall contain the following: • Supply On /Off Switch • Heat On /Off Switch • Blower Light • Main Valve Light • Room temperature sensor and set point dial. Unit Start-Up Sequence • Supply Fan Enable Is Received • Supply Fan Is Enabled Supply Fan Sequence The unit has been provided with a factory mounted variable frequency drive (VFD). The variable frequency drive shall control the supply fan speed as indicated by the following sequence: Constant Volume The VFD shall be programmed from the factory for a constant supply fan speed. This is to be adjusted for air balancing only and is not to be modulated. Heating Control A heating enable signal must be present and the supply fan must enabled before the unit will enable heating. Heating Inlet Air Sensor (Heating Lockout) The heating will be locked out when the outside air temperature is above the heating inlet air sensor set point (typical 65 F, adj.) Direct Gas Fired Heating (Room Control) The gas control amplifier located in the unit shall modulate the heating to maintain a room temperature set point. A discharge temperature sensor limits the supply temperature to the minimum (50 F adj.) and maximum set points (100 F adj.) on the amplifier. • The room temperature sensor and set point dial is mounted on the remote panel. Generated by:druby@johnsonair.com CAPS 4.33.1049 G:\DannyRuby\Secured Jobs 2020\A-F\Durham AWWTF Bisulfite Storage Room.gfcj Page 12 of 13 Air Handling Unit (MAU-1) Printed Da.9.6i dk)i)/S 0 0GREENHECK Job: Durham AWWTF Bisulfite Storage Room Building Value in Air. Mark: 810MAU5001 Model: DGX-P120-H22 Warranty Statement for Make-Up Air Unit Warranty Greenheck warrants the equipment to be free from defects in material and workmanship for a period of 1 year(standard)from the shipment date. DG Burner Extended Warranty The warranty does not include items deemed as consumable components, including, but not limited to: Igniters, Spark rods, Spark generator, Flame rods,Flame wires, UV eye components, and associated components. Note: Rust, discoloration of the burner material and cracks or holes smaller than .75 in. is not qualification for a defective burner. Warranty Notes Any component which proves defective during the warranty period will be repaired or replaced at Greenheck's sole option when returned to our factory, transportation prepaid. All warranties do not include labor costs associated with troubleshooting, removal, or installation. Greenheck will not be liable for any consequential, punitive,or incidental damages resulting from use, repair, or operation of any Greenheck product. These warranties are exclusive and are in lieu of all other warranties,whether written, oral, or implied, including the warranty of merchantability and the warranty of fitness for a particular purpose. No person (including any agent or salesperson)has authority to expand Seller's obligation beyond the terms of this warranty, or to state that the performance of the product is other than that published by Seller. As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Tempered Air Products(TAP) Statement 2018 Generated by:druby@johnsonair.com CAPS 4.33.1049 G:\DannyRuby\Secured Jobs 2020\A-F1Durham AWWTF Bisulfite Storage Room.gfcj Page 13 of 13 CDI EXISTING CURB VERIFICATION Page 17 of20 S2 RB2 — 51 -Dr a tensions to be verified eat r MAD approved submittal. RB1 - — R2 SB2— i i— rRI rSB1 V } }3 }3 I SB-f— R}3 iR4 RETURN SUPPLY S4 OD2' SB4 SUPPLY RETURN RB4 OD2` f - I f OD1` I I OD1" - --d EXISTING OPTION A EXISTING OPTION B PLEASE DO NOT USE RTU DIMENSIONS OD1 EXISTING OD1 UNIT OD2 OD2 BRAND R1 MODEL RB1 R2 THE CURB O SDDING(OD1 8 OD2).PLEASE PROVIDE RB2 ONLY ACTUAL CURB DIMENSIONS(DO NOT ADD RB3 R3 OVERSIZE) Please also note the followina information RB4 R4 -Note any obstructions near the existing curb (EX.Wall,Other units,Hoods,etc) SB1 S1 •Note any height restrictions. -Note existing curb height. SB2 S2 PLEASE FILL IN CURB DIMENSIONS"OD1" SB3 S3 THROUGH"S•4",FEEL FREE TO CALL (1-868-234-7001)WITH ANY QUESTIONS OR S4 CHECKOUT THESE MEASURING INSTRUCTIONS: SB4 —CDI EXISTING CURB https://cdicurbs.com/pdf/cdl_measure_instructIons.pdf VERIFICATION ,be G12 v. "re020 CDI TILER ST NW C CDn05t311--7700 33"ar 1 w 2 CDI EXISTING CURB VERIFICATION Page 18 of 20 RC1 RC2 SC1— RC3 ISC2— + SC3 EXISTING OPTION C PLEASE DO NOT USE RTu DIMENSIONS EXISTING RC4 SC4 OD1 UNIT RETURN SUPPLY -- BRAND OD2 MODEL RC1 *COI WILL BE ADDING 1-1l2-(1.5")OVERSIZE TO RC2 THE CURB OD'S (ODI&OD2).PLEASE PROVIDE ONLY ACTUAL CURB DIMENSIONS(DO NOT ADD OD2* RC3 OVERSIZE) Please also note the followina information RC4 -Note any obstructions near the existing curb (EX.Wall,Other units,Hoods,etc) SCi -Note any height restrictions. -Note existing curb height. SC2 PLEASE FILL IN CURB DIMENSIONS"OD1" SC3 THROUGH"S*4",FEEL FREE TO CALL OD1' -I - (1-888-234-7001)WITH ANY QUESTIONS OR SC4 CHECKOUT THESE MEASURING INSTRUCTIONS https:Ilcdicurbs.comlpdflcdl_measure_instructlon s.pdf -COI EXISTING CURB VERIFICATION rt3re000000 501312020 175W TYLER ST NW cn rELI<RNERMX559]0 lL/L I881*1�TIW Ii89p91�785t (.an 4 x 3 1Ly..13 J 20 100. CRICKET(PEAK) NOTE:CURBS 120"OR LONGER ON THE PEAK WALL WILL NOT HAVE A CRICKET(PEAK) CRICKET PLEASE INDICATE PITCH ORIENTATION BY SKETCHING &LABELING THE RETURN & SUPPLY OF YOUR UNIT ROOF PITCH= PER FT a,e. o ""` PITCH CURB ORIENTATION DRAWING warm— Ir. nsao TYLERST Nw '� _ CDIELNRIVER MN 99889 'P?PiKN 2 (7IS3}�]]991-R90 wr (TSJ�]91.T851 m�. <1N I uen 1 or 1 SICURBS_CURB ADAPTERS1201 CDICUSTOM CURBO4rd- Unit (MAU-1) Page 20 of 20 CALCULATION REQUIREMENTS CDI CALCULATION REQUIREMENTS -REQUIRED ITEMS: If ALL of the below items are not able to be provided, please provide the full contract drawings and specifications section for the building or structure Project Address: Mean Roof Height/Attachment Height(list both if different): Items listed in SEISMIC SPECIFICATIONS: SDS= Items listed in WIND SPECIFICATIONS: Wind Speed = Is this structure a: (check one) HOSPITAL SCHOOL OTHER ESSENTIAL FACILITY n ROOF ATTACHMENT TYPE:(check one,assuming typical connections conforming to CDI standard connections) Concrete Steel Wood n Adapter Curb If NON-STANDARD Specify: OTHER ITEMS (not required, if not provided items will be assumed by designer): DESIGN CODE to be referenced:(check one) IBC ASCE 7-10 STATE Items listed in SEISMIC SPECIFICATIONS: Ip (Importance Factor) _ Rp (Response Modification Factor) = Ap (Amplification Factor) _ Items listed in WIND SPECIFICATIONS: Exposure Category = Ip(Risk Category) _ CDI Custom Curb Adapters — 1-888-234-7001 — www.cdicurbs.com